{"product_id":"tigerflow-tigercub-cd20-simplex-booster-system","title":"TIGERFLOW Tigercub CD20 Simplex Variable Speed Booster System","description":"\u003c!-- TABS --\u003e\n\u003ch5\u003eDescription\u003c\/h5\u003e\n\u003cdiv class=\"gs\"\u003e\n\u003cdiv class=\"gs-head\"\u003e\n\u003cdiv class=\"gs-eyebrow\"\u003eTIGERFLOW · Simplex Booster System\u003c\/div\u003e\n\u003cdiv class=\"gs-title\"\u003eTigercub CD20\u003c\/div\u003e\n\u003cdiv class=\"gs-sub\"\u003ePackaged simplex booster on a TIGERFLOW CD20 vertical multistage pump with variable frequency drive: 2 models, 5 to 7-1\/2 HP, single or three phase.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"gs-badges\"\u003e\n\u003cdiv class=\"gs-badge\" style=\"background:#B3122A;color:#FFFFFF;border-color:#B3122A\"\u003e56-85 PSI Max Boost · 154 GPM Max\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003e5 to 7-1\/2 HP\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003e208-230V 1Ph; 208-230V or 460V 3Ph\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003e2 in Union-Ball Valves, Suction and Discharge\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003eVariable Frequency Drive\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003eUL 508A Listed Disconnect Panel\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003eStainless Steel Pump and Piping\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003eUL \/ cUL Listed Packaged System (QCZJ)\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003e34.25 x 17 x 34.7-39.5 in\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003e193-219 lb Weight\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eOverview\u003c\/div\u003e\n\u003cdiv class=\"gs-lead\"\u003e\n\u003cp\u003eThe Tigercub is TIGERFLOW’s simplex booster system for small commercial buildings: medium-size apartment buildings, residential, hotels, municipal sites and shopping centers. Each one is a TIGERFLOW CD20 vertical multistage pump on a stainless steel base and manifold, with a variable frequency drive, a UL 508A listed disconnect panel and the valves already piped, prefabricated and factory tested as one UL \/ cUL listed packaged pumping system. The drive holds a constant pressure as demand changes, slowing the pump at low flow.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eNon-slam, center-guided stainless steel check valve\u003c\/li\u003e\n\u003cli\u003eLow suction or low-level alarm\u003c\/li\u003e\n\u003cli\u003eLiquid-filled pressure gauges and vibration isolators\u003c\/li\u003e\n\u003cli\u003eUnion-ball valves on suction and discharge, with pressure port\u003c\/li\u003e\n\u003cli\u003eSingle source responsibility, with a certificate of product liability insurance\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background:#FFFFFF;border:1px solid #C7CBD1;border-top:3px solid #B3122A;padding:12px 16px 12px;margin:16px 0 4px;font-size:13.5px;line-height:1.55;color:#4A4A4F\"\u003e\n\u003cdiv style=\"font-family:Arial Black,Arial,sans-serif;font-size:11px;letter-spacing:1.2px;text-transform:uppercase;color:#B3122A;margin-bottom:8px\"\u003eWhat Ships and What It Needs to Run\u003c\/div\u003e\n\u003cp style=\"margin:0 0 6px\"\u003e\u003cstrong style=\"color:#B3122A\"\u003eIncluded:\u003c\/strong\u003e the CD20 vertical multistage pump and TEFC motor, variable frequency drive, UL 508A listed disconnect panel, non-slam stainless steel check valve, low suction or low-level alarm, liquid-filled pressure gauges, vibration isolators, and 2 in union-ball valves on suction and discharge with pressure port, prefabricated and factory tested on one base.\u003c\/p\u003e\n\u003cp style=\"margin:0 0 6px\"\u003e\u003cstrong style=\"color:#B3122A\"\u003eExpansion tank, recommended, ordered separately.\u003c\/strong\u003e TIGERFLOW’s 2-gallon, 150 PSI diaphragm tank minimizes system cycling during leak-load conditions; larger tanks are options. See our \u003ca href=\"\/products\/tigerflow-tigercub-diaphragm-expansion-tank\"\u003eTigercub expansion tanks\u003c\/a\u003e. A \u003ca href=\"\/products\/tigerflow-tigercub-thermal-purge-valve\"\u003ethermal purge valve\u003c\/a\u003e (option) helps prevent pump damage in low-flow conditions.\u003c\/p\u003e\n\u003cp style=\"margin:0\"\u003e\u003cstrong style=\"color:#B3122A\"\u003eSuction and discharge piping, power feed:\u003c\/strong\u003e sized to your building and ordered separately.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background:#E1E3E6;border-left:3px solid #B8BDC4;padding:8px 14px;font-size:11.5px;color:#4A4A4F;margin-top:14px;line-height:1.5\"\u003eGenuine TIGERFLOW equipment, factory-new in original packaging — sold and supported by Watermain Supply, an independent industrial supplier.\u003c\/div\u003e\n\u003cdiv style=\"background:#fff;border-left:5px solid #B3122A;padding:15px 18px;margin-top:12px\"\u003e\n\u003cdiv style=\"font-family:Arial Black,Arial,sans-serif;font-size:15px;color:#B3122A;text-transform:uppercase;letter-spacing:1px;margin-bottom:6px\"\u003e12-Month TIGERFLOW Warranty\u003c\/div\u003e\n\u003cp style=\"margin:0;font-size:13.5px;color:#4A4A4F;line-height:1.55\"\u003eCovered for \u003cstrong\u003e12 months from the date of purchase\u003c\/strong\u003e under TIGERFLOW’s published warranty terms.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eSingle Unit\u003c\/div\u003e\n\u003cdiv class=\"gs-lead\"\u003e\n\u003cp\u003eThe Tigercub is a simplex package. Size it to the building’s full peak demand now; TIGERFLOW builds duplex and larger packaged booster systems to order where the building needs a standby pump or more flow.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eSpecifications\u003c\/div\u003e\n\u003cdiv class=\"gs-lead\"\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePump\u003c\/td\u003e\n\u003ctd\u003eTIGERFLOW CD20 vertical multistage, 304\/316 stainless impellers; 5 to 7-1\/2 HP TEFC motor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower\u003c\/td\u003e\n\u003ctd\u003e208-230V 1Ph; 208-230V or 460V 3Ph, 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl\u003c\/td\u003e\n\u003ctd\u003eVariable frequency drive; UL 508A listed disconnect panel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnections\u003c\/td\u003e\n\u003ctd\u003e2 in union-ball valves on suction and discharge, with pressure port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFootprint\u003c\/td\u003e\n\u003ctd\u003e34.25 x 17 in base; 34.7 to 39.5 in tall by model\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnergy rating\u003c\/td\u003e\n\u003ctd\u003ePEI(CL) 0.95 to 0.97 by model\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePump maximum working pressure\u003c\/td\u003e\n\u003ctd\u003e362 PSI (CD Series rating)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertification\u003c\/td\u003e\n\u003ctd\u003eUL \/ cUL listed packaged pumping system, label QCZJ; CD pump certified to NSF\/ANSI 61 and 372\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApp or remote connectivity\u003c\/td\u003e\n\u003ctd\u003eNone published — it runs from its drive and panel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eModels \u0026amp; Performance — Will It Do What You Need?\u003c\/div\u003e\n\u003cdiv class=\"gs-lead\"\u003e\n\u003cp\u003ePressure the pump adds at each flow, in PSI, at full speed. Find your model and read across; the first column is the most it can add.\u003c\/p\u003e\n\u003cp style=\"margin-bottom:4px\"\u003e\u003cstrong\u003eCD20 · Pressure added in PSI, pump at full speed · curves end at 154.1 GPM\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003cth\u003e0 GPM (Shut-off)\u003c\/th\u003e\n\u003cth\u003e58 GPM\u003c\/th\u003e\n\u003cth\u003e88 GPM\u003c\/th\u003e\n\u003cth\u003e116 GPM\u003c\/th\u003e\n\u003cth\u003e154 GPM\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cstrong\u003eCD20-2\u003c\/strong\u003e · 5 HP\u003c\/td\u003e\n\u003ctd\u003e56\u003c\/td\u003e\n\u003ctd\u003e53\u003c\/td\u003e\n\u003ctd\u003e50\u003c\/td\u003e\n\u003ctd\u003e45\u003c\/td\u003e\n\u003ctd\u003e30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cstrong\u003eCD20-3\u003c\/strong\u003e · 7-1\/2 HP\u003c\/td\u003e\n\u003ctd\u003e85\u003c\/td\u003e\n\u003ctd\u003e81\u003c\/td\u003e\n\u003ctd\u003e76\u003c\/td\u003e\n\u003ctd\u003e67\u003c\/td\u003e\n\u003ctd\u003e46\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp\u003e\u003cstrong\u003eDrawing from a tank or cistern\u003c\/strong\u003e — nothing arrives with pressure, so what the pump adds is what you get. Read the table straight through: the CD20-3 adds 76 PSI at 88 GPM.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFed by a city main\u003c\/strong\u003e — the pump adds on top of what already arrives, and the drive slows it to hold your set point. With 40 PSI arriving, the CD20-3 still adds 46 PSI at 154 GPM, near its 154.1 GPM curve end, so it holds 86 PSI there; at a lower set point it needs to add less and runs slower. \u003cstrong\u003eIncoming pressure turns into extra flow at the same set point.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp style=\"font-size:12.5px;color:#9B9EA3;margin-top:6px;line-height:1.55\"\u003eRead from the published CD20 curves in the TIGERFLOW CD Series Vertical Multistage Pumps catalog (60 Hz, 3500 RPM), pp. 21-22, digitized from the catalog’s vector curve data and rounded down to whole PSI. Zero flow is the shut-off point — a ceiling, not a working point; TIGERFLOW prints no separate shut-off figure, so the 0 GPM column is where the dashed part of each curve meets zero flow. The solid (recommended) part of each curve starts at 57.2 GPM; 58 GPM is the first column inside it, the next two sit near 50% and 75% of the curve end, and the last column is the last regular digitized flow every curve reaches (the curve end is named above the table where it runs a little further). Single- and three-phase builds and the HP options of the same model run on the same curve. Feet of head = PSI × 2.31. The full curve, with power per stage and NPSHr, is in the image gallery. The figures are at full speed; the drive holds lower pressures by running slower. The Tigercub catalog prints the same single-pump curves (marked 3600 RPM).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBest operating range:\u003c\/strong\u003e 57.2 to 154.1 GPM, the solid section of the published pump curve. This is where the pump turns the most electricity into water pressure. Ask for more flow than it can deliver at your setting and it runs at full speed continuously, which is where motors and seals wear out. Sizing a booster to the building rather than to the headline numbers is what makes it last.\u003c\/p\u003e\n\u003cdiv style=\"display:flex;flex-wrap:wrap;gap:10px;margin:22px 0 4px\"\u003e\n\u003ca href=\"\/pages\/booster-pump-sizing-calculator\" style=\"flex:1 1 200px;text-align:center;display:block;background:#B3122A;color:#ffffff;font-family:Arial Black,Arial,sans-serif;font-size:12px;text-transform:uppercase;letter-spacing:1.2px;padding:11px 18px;text-decoration:none\"\u003eBooster Calculator\u003c\/a\u003e\u003ca href=\"\/pages\/pressure-tank-sizing-calculator\" style=\"flex:1 1 200px;text-align:center;display:block;background:#B3122A;color:#ffffff;font-family:Arial Black,Arial,sans-serif;font-size:12px;text-transform:uppercase;letter-spacing:1.2px;padding:11px 18px;text-decoration:none\"\u003eTank Calculator\u003c\/a\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eBefore You Buy — The Limits That Decide the Fit\u003c\/div\u003e\n\u003cdiv class=\"gs-lead\"\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSet point\u003c\/td\u003e\n\u003ctd\u003eSet on the drive. TIGERFLOW publishes no separate maximum set point; incoming plus added pressure must stay within the pump’s 362 PSI rating.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSuction\u003c\/td\u003e\n\u003ctd\u003eFlooded suction or a pressurized supply; the pump does not prime itself. The low suction or low-level alarm is standard.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower\u003c\/td\u003e\n\u003ctd\u003e208-230V 1Ph; 208-230V or 460V 3Ph. 7-1\/2 HP builds are three phase only.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBest operating range\u003c\/td\u003e\n\u003ctd\u003e57.2 to 154.1 GPM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIntegrated vessel\u003c\/td\u003e\n\u003ctd\u003eNone; a 2-gallon expansion tank is the recommended option for leak loads. A thermal expansion tank is still required at any storage water heater.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePairing\u003c\/td\u003e\n\u003ctd\u003eSingle unit; duplex and larger systems are built to order.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWater temperature\u003c\/td\u003e\n\u003ctd\u003ePump rated 5°F to 248°F (158°F standard type per the CD manual); confirm package limits for hot water.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eApplications\u003c\/div\u003e\n\u003cdiv class=\"gs-lead\"\u003e\n\u003cp\u003eMedium-size apartment buildings, residential, hotels, municipal and shopping centers.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eAccessories\u003c\/div\u003e\n\u003cdiv class=\"gs-lead\"\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eAccessory\u003c\/th\u003e\n\u003cth\u003eCode\u003c\/th\u003e\n\u003cth\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/tigerflow-tigercub-diaphragm-expansion-tank\"\u003eExpansion tank, 2 gallon\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e3200013721\u003c\/td\u003e\n\u003ctd\u003eAmtrol ST-5, 150 PSI, 38 PSI precharge, NSF-61 antimicrobial liner\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/tigerflow-tigercub-diaphragm-expansion-tank\"\u003eExpansion tanks, 10.3 to 44 gallon\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eBy size\u003c\/td\u003e\n\u003ctd\u003eAmtrol ST series, 150 PSI; ASME 34-gallon option\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/tigerflow-tigercub-thermal-purge-valve\"\u003eThermal purge valve\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e3200018898\u003c\/td\u003e\n\u003ctd\u003e1\/4 in, 400 PSI, opens at 125°F, fully open at 135°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/tigerflow-tigercub-thermal-purge-valve\"\u003eThermal purge assembly, simplex\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e3200026682\u003c\/td\u003e\n\u003ctd\u003ePurge assembly for the simplex package\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eService Parts\u003c\/div\u003e\n\u003cdiv class=\"gs-lead\"\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003ePart\u003c\/th\u003e\n\u003cth\u003eCode\u003c\/th\u003e\n\u003cth\u003eFits\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/tigerflow-cd-cartridge-mechanical-seal\"\u003eCartridge mechanical seal\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e3200019765\u003c\/td\u003e\n\u003ctd\u003eCD20 pump\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/tigerflow-cd20-vertical-multistage-pump-end\"\u003eCD20 pump end\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eBy model\u003c\/td\u003e\n\u003ctd\u003ePump rebuild\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/tigerflow-tefc-pump-motor\"\u003eTEFC replacement motor\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eBy HP\u003c\/td\u003e\n\u003ctd\u003e1 to 7-1\/2 HP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"gs-contact\"\u003eFor engineering-led sizing and selection support or a factory submittal, email \u003ca href=\"mailto:sales@watermainsupply.com\"\u003esales@watermainsupply.com\u003c\/a\u003e or call \u003ca href=\"tel:18885104036\"\u003e1-888.510.4036\u003c\/a\u003e.\u003cbr\u003e© Watermain Supply — A division of E4 Industrial LLC\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch5\u003eData Sheet\u003c\/h5\u003e\n\u003cdiv class=\"gs\"\u003e\n\u003cdiv class=\"gs-dl\"\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0264\/1913\/4527\/files\/2022-TIGERCUB-CD-CATALOG.pdf?v=1792271197\" target=\"_blank\" rel=\"noopener\"\u003eTigercub CD Catalog: Dimensions, Options and Curves\u003c\/a\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0264\/1913\/4527\/files\/CD-Series-Catalog-2023.pdf?v=1792271198\" target=\"_blank\" rel=\"noopener\"\u003eCD Series Vertical Multistage Pumps Catalog (2023)\u003c\/a\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch5\u003eVideos\u003c\/h5\u003e\n\u003cdiv class=\"gs\"\u003e\u003cdiv class=\"gs-sec\" style=\"margin-top:6px\"\u003e\n\u003cp style=\"font-size:13px;color:#9B9EA3\"\u003eProduct videos are being added to this listing. For a walkthrough in the meantime, email sales@watermainsupply.com.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003c!-- \/TABS --\u003e","brand":"TIGERFLOW","offers":[{"title":"56 PSI Max Boost - 154 GPM Max \/ 5 HP - 208-230V 1Ph \/ CD20-2","offer_id":50690245197999,"sku":"3300005255","price":11735.58,"currency_code":"USD","in_stock":true},{"title":"56 PSI Max Boost - 154 GPM Max \/ 5 HP - 208-230V 3Ph \/ CD20-2","offer_id":50690245230767,"sku":"3300005256","price":11119.83,"currency_code":"USD","in_stock":true},{"title":"56 PSI Max Boost - 154 GPM Max \/ 5 HP - 460V 3Ph \/ CD20-2","offer_id":50690245263535,"sku":"3300005257","price":11021.47,"currency_code":"USD","in_stock":true},{"title":"85 PSI Max Boost - 154 GPM Max \/ 7-1\/2 HP - 208-230V 3Ph \/ CD20-3","offer_id":50690245296303,"sku":"3300005258","price":12395.12,"currency_code":"USD","in_stock":true},{"title":"85 PSI Max Boost - 154 GPM Max \/ 7-1\/2 HP - 460V 3Ph \/ CD20-3","offer_id":50690245329071,"sku":"3300005259","price":12761.6,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0264\/1913\/4527\/files\/tigerflow-tigercub-simplex-booster-photo_295d0470-a219-4c65-a303-0471e1dcc92d.jpg?v=1792275036","url":"https:\/\/watermainsupply.com\/products\/tigerflow-tigercub-cd20-simplex-booster-system","provider":"Watermainsupply","version":"1.0","type":"link"}