{"product_id":"grundfos-unilift-kp-submersible-pump","title":"Grundfos Unilift KP Submersible Pump","description":"\u003c!-- TABS --\u003e\n\u003ch5\u003eDescription\u003c\/h5\u003e\n\u003cdiv class=\"gs\"\u003e\n\n\u003cdiv class=\"gs-head\"\u003e\n\u003cdiv class=\"gs-eyebrow\"\u003eGRUNDFOS · SUBMERSIBLE DRAINAGE PUMP\u003c\/div\u003e\n\u003cdiv class=\"gs-title\"\u003eUNILIFT KP\u003c\/div\u003e\n\u003cdiv class=\"gs-sub\"\u003eStainless-steel submersible drainage pump for clean and slightly dirty water, with the pump fully or partly submerged. Three motor sizes — KP 150, KP 250 and KP 350 — all 115 V with a 1-1\/4 in NPT top discharge and 0.4 in solids handling.\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"gs-badges\"\u003e\n\u003cdiv class=\"gs-badge\"\u003e0.4 in Max Solids\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003e1-1\/4 in NPT Discharge\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003e115V 1Ph · 25 ft Cord\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003eAISI 304 Stainless\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003eIP68 · 30 ft Submergence\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eOverview\u003c\/div\u003e\n\u003cdiv class=\"gs-lead\"\u003e\n\u003cp\u003eUNILIFT KP is designed for liquid transfer and drainage of clean or slightly dirty wastewater with the pump completely or partly submerged in the liquid. It suits drainage of flooded cellars or buildings, pumping of domestic wastewater without toilet waste, emptying of pools, tanks and vessels, and pumping within agriculture, the dairy industry, horticulture and the process industry.\u003c\/p\u003e\n\u003cp\u003eThe pump is a single-stage, submersible, stainless-steel drainage pump in a robust design with an upward-pointing discharge port placed on top of the pump. Water enters through the holes of the suction strainer, which prevents the passage of large solids. The sturdy impeller has single-curved vanes with bevelled front edges that prevent fibres from jamming the impeller. The guide vanes in the pump housing guide the liquid, lifting sand grains into the liquid flow and so preventing blocking by sand.\u003c\/p\u003e\n\u003cp\u003eThe pump sleeve is made in one piece. The mains cable enters through a vulcanized and water-tight plug, secured to the socket of the hermetically sealed stator housing. The motor is a single-phase asynchronous canned motor with a liquid-filled rotor chamber and water-lubricated bearings, cooled by the pumped liquid around the motor. It incorporates automatic overload protection: on overload the motor stops and, once cooled, restarts automatically.\u003c\/p\u003e\n\u003cp\u003eMaximum particle size is 0.4 in. Liquid temperature range is 32 °F to 122 °F, with 158 °F permitted for periods not exceeding two minutes at intervals of at least 30 minutes. Maximum installation depth is 30 ft below liquid level. The pumps are suitable for temporary as well as permanent free-standing installation and are not designed for continuous operation.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"background:#E1E3E6;border-left:3px solid #B8BDC4;padding:8px 14px;font-size:11.5px;color:#4A4A4F;margin-top:14px;line-height:1.5\"\u003eGenuine Grundfos equipment, factory-new in original packaging — sold and supported by Watermain Supply, an independent industrial distributor.\u003c\/div\u003e\n\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003ePerformance — Will It Do What You Need?\u003c\/div\u003e\n\u003cp style=\"font-size:13.5px;margin-bottom:10px\"\u003eFind your \u003cstrong\u003evertical lift\u003c\/strong\u003e down the left. The figure is the \u003cstrong\u003emaximum combined vertical plus horizontal Schedule 40 PVC pipe run\u003c\/strong\u003e Grundfos allows for that model at that lift.\u003c\/p\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eVertical lift\u003c\/th\u003e\n\u003cth\u003eKP 150\u003c\/th\u003e\n\u003cth\u003eKP 250\u003c\/th\u003e\n\u003cth\u003eKP 350\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e4 ft\u003c\/td\u003e\n\u003ctd\u003e400 ft\u003c\/td\u003e\n\u003ctd\u003e775 ft\u003c\/td\u003e\n\u003ctd\u003e950 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e8 ft\u003c\/td\u003e\n\u003ctd\u003e250 ft\u003c\/td\u003e\n\u003ctd\u003e625 ft\u003c\/td\u003e\n\u003ctd\u003e800 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e12 ft\u003c\/td\u003e\n\u003ctd\u003e100 ft\u003c\/td\u003e\n\u003ctd\u003e450 ft\u003c\/td\u003e\n\u003ctd\u003e625 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e14 ft\u003c\/td\u003e\n\u003ctd\u003e30 ft\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e16 ft\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e300 ft\u003c\/td\u003e\n\u003ctd\u003e500 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e20 ft\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e150 ft\u003c\/td\u003e\n\u003ctd\u003e350 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e22 ft\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e75 ft\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e24 ft\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e175 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e26 ft\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e100 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"font-size:12.5px;color:#9B9EA3;margin-top:8px;line-height:1.55\"\u003eGrundfos publishes this overview as a guide only. If a non-return valve is fitted, deduct approximately 0.6 ft of head from the vertical pipe length. Measure the vertical height of the discharge pipe from the pump stop level. A dash means Grundfos publishes no figure for that model at that lift.\u003c\/p\u003e\n\u003cp style=\"font-size:12.5px;color:#9B9EA3;margin-top:8px;line-height:1.55\"\u003eFlow velocity through the outlet pipe must be at least 2.3 ft\/s to keep the line self-cleaning. A Schedule 40 PVC outlet pipe with a 1.38 in inner diameter needs roughly 12 gpm to achieve it. Across the KP range Grundfos publishes a maximum flow of 65 GPM and a maximum head of 32 ft; both belong to KP 350 and are range ceilings, not a single duty point.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eModels, Voltage \u0026amp; Phase\u003c\/div\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003cth\u003eHP\u003c\/th\u003e\n\u003cth\u003eVoltage \u0026amp; Phase\u003c\/th\u003e\n\u003cth\u003eLevel Control\u003c\/th\u003e\n\u003cth\u003ePart No.\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eUNILIFT KP 150 M-1\u003c\/td\u003e\n\u003ctd\u003e1\/4\u003c\/td\u003e\n\u003ctd\u003e115V 1Ph\u003c\/td\u003e\n\u003ctd\u003eManual — no float switch\u003c\/td\u003e\n\u003ctd\u003e011DC201\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUNILIFT KP 250 M-1\u003c\/td\u003e\n\u003ctd\u003e1\/3\u003c\/td\u003e\n\u003ctd\u003e115V 1Ph\u003c\/td\u003e\n\u003ctd\u003eManual — no float switch\u003c\/td\u003e\n\u003ctd\u003e012DC201\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUNILIFT KP 350 M-1\u003c\/td\u003e\n\u003ctd\u003e1\/2\u003c\/td\u003e\n\u003ctd\u003e115V 1Ph\u003c\/td\u003e\n\u003ctd\u003eManual — no float switch\u003c\/td\u003e\n\u003ctd\u003e013DC201\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"font-size:12.5px;color:#9B9EA3;margin-top:8px;line-height:1.55\"\u003eWhere two voltages are shown, the first is the factory wiring setting. Voltage is changed on the motor terminal board, never at the pressure switch. All models are single phase unless the table states 3Ph.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eKey Features\u003c\/div\u003e\n\u003cdiv class=\"gs-lead\"\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eAll-stainless wet end\u003c\/strong\u003e — sleeve, housing, suction strainer, impeller, guide vanes and stator housing in AISI 304; shaft in AISI 431.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSand-shedding hydraulics\u003c\/strong\u003e — guide vanes lift sand grains into the liquid flow, preventing the pump blocking with sand.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAnti-jam impeller\u003c\/strong\u003e — single-curved vanes with bevelled front edges stop fibres jamming the impeller.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSealed cable entry\u003c\/strong\u003e — vulcanized, water-tight plug secured to the socket of the hermetically sealed stator housing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBuilt-in motor protection\u003c\/strong\u003e — automatic overload protection stops the motor and restarts it once cooled; no additional motor protection required.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounts three ways\u003c\/strong\u003e — vertical with the discharge port upwards, or horizontal or tilted with the discharge port as the highest point of the pump.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCSA C\/US approved\u003c\/strong\u003e, IP68 enclosure, insulation class F.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eSpecifications\u003c\/div\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePump type\u003c\/td\u003e\n\u003ctd\u003eSingle-stage submersible drainage pump, free-standing installation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum particle size\u003c\/td\u003e\n\u003ctd\u003e0.4 in (10 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eImpeller\u003c\/td\u003e\n\u003ctd\u003eSemi-open, 2-pole\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLiquid temperature\u003c\/td\u003e\n\u003ctd\u003e32 °F to 122 °F (158 °F for up to 2 minutes at intervals of at least 30 minutes)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH range\u003c\/td\u003e\n\u003ctd\u003e4 to 9\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum liquid density\u003c\/td\u003e\n\u003ctd\u003e146.88 oz\/gal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum installation depth\u003c\/td\u003e\n\u003ctd\u003e30 ft below liquid level\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDischarge connection\u003c\/td\u003e\n\u003ctd\u003eRp 1-1\/4 in (1.25 in NPT), vertical, top of pump\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure class\u003c\/td\u003e\n\u003ctd\u003eIP68\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsulation class\u003c\/td\u003e\n\u003ctd\u003eF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor\u003c\/td\u003e\n\u003ctd\u003eSingle-phase asynchronous canned motor, liquid-filled rotor chamber, water-lubricated bearings\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor protection\u003c\/td\u003e\n\u003ctd\u003eAutomatic thermal overload with auto-restart\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable\u003c\/td\u003e\n\u003ctd\u003e25 ft, 16 AWG 3\/C SJOW 90C, NEMA 5 plug\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApprovals\u003c\/td\u003e\n\u003ctd\u003eCSA C\/US\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eElectrical \u0026amp; Dimensional Data\u003c\/div\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003cth\u003eP1 [hp]\u003c\/th\u003e\n\u003cth\u003eIn [A]\u003c\/th\u003e\n\u003cth\u003eI start [A]\u003c\/th\u003e\n\u003cth\u003eWeight [lbs]\u003c\/th\u003e\n\u003cth\u003eH [in]\u003c\/th\u003e\n\u003cth\u003eB1 [in]\u003c\/th\u003e\n\u003cth\u003eB2 [in]\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eKP 150\u003c\/td\u003e\n\u003ctd\u003e0.353\u003c\/td\u003e\n\u003ctd\u003e2.9\u003c\/td\u003e\n\u003ctd\u003e8.7\u003c\/td\u003e\n\u003ctd\u003e14.33\u003c\/td\u003e\n\u003ctd\u003e8.86\u003c\/td\u003e\n\u003ctd\u003e5.87\u003c\/td\u003e\n\u003ctd\u003e1.22\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eKP 250\u003c\/td\u003e\n\u003ctd\u003e0.569\u003c\/td\u003e\n\u003ctd\u003e4.9\u003c\/td\u003e\n\u003ctd\u003e14.5\u003c\/td\u003e\n\u003ctd\u003e15.43\u003c\/td\u003e\n\u003ctd\u003e8.86\u003c\/td\u003e\n\u003ctd\u003e5.87\u003c\/td\u003e\n\u003ctd\u003e1.22\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eKP 350\u003c\/td\u003e\n\u003ctd\u003e0.748\u003c\/td\u003e\n\u003ctd\u003e7.5\u003c\/td\u003e\n\u003ctd\u003e21.4\u003c\/td\u003e\n\u003ctd\u003e17.64\u003c\/td\u003e\n\u003ctd\u003e9.25\u003c\/td\u003e\n\u003ctd\u003e5.87\u003c\/td\u003e\n\u003ctd\u003e1.22\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"font-size:12.5px;color:#9B9EA3;margin-top:8px;line-height:1.55\"\u003eP1 is motor input power from the Grundfos technical data table; the HP figure in the models table is the nominal rating. Weights are pump weights; shipping weights differ. Space required corresponds to the physical dimensions of the pump.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eMaterials\u003c\/div\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eComponent\u003c\/th\u003e\n\u003cth\u003eMaterial\u003c\/th\u003e\n\u003cth\u003eDIN W.-Nr.\u003c\/th\u003e\n\u003cth\u003eAISI\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePump sleeve\u003c\/td\u003e\n\u003ctd\u003eStainless steel\u003c\/td\u003e\n\u003ctd\u003e1.4301\u003c\/td\u003e\n\u003ctd\u003e304\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePump housing\u003c\/td\u003e\n\u003ctd\u003eStainless steel\u003c\/td\u003e\n\u003ctd\u003e1.4301\u003c\/td\u003e\n\u003ctd\u003e304\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSuction strainer\u003c\/td\u003e\n\u003ctd\u003eStainless steel\u003c\/td\u003e\n\u003ctd\u003e1.4301\u003c\/td\u003e\n\u003ctd\u003e304\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eImpeller\u003c\/td\u003e\n\u003ctd\u003eStainless steel\u003c\/td\u003e\n\u003ctd\u003e1.4301\u003c\/td\u003e\n\u003ctd\u003e304\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShaft\u003c\/td\u003e\n\u003ctd\u003eStainless steel\u003c\/td\u003e\n\u003ctd\u003e1.4057\u003c\/td\u003e\n\u003ctd\u003e431\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStator housing\u003c\/td\u003e\n\u003ctd\u003eStainless steel\u003c\/td\u003e\n\u003ctd\u003e1.4301\u003c\/td\u003e\n\u003ctd\u003e304\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGuide vanes\u003c\/td\u003e\n\u003ctd\u003eStainless steel\u003c\/td\u003e\n\u003ctd\u003e1.4301\u003c\/td\u003e\n\u003ctd\u003e304\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBearings\u003c\/td\u003e\n\u003ctd\u003eCarbon\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eO-rings, seal rings\u003c\/td\u003e\n\u003ctd\u003eNBR\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable\u003c\/td\u003e\n\u003ctd\u003e16 AWG 3\/C SJOW 90C\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eApplications\u003c\/div\u003e\n\u003cdiv class=\"gs-lead\"\u003e\n\u003cul\u003e\n\u003cli\u003eDrainage of flooded cellars or buildings\u003c\/li\u003e\n\u003cli\u003ePumping of domestic wastewater without toilet waste\u003c\/li\u003e\n\u003cli\u003eEmptying of pools, tanks and vessels\u003c\/li\u003e\n\u003cli\u003eWater and rainwater in horticulture; water from rivers and lakes\u003c\/li\u003e\n\u003cli\u003eRainwater, drainage water and water from flooding; ditch drainage water\u003c\/li\u003e\n\u003cli\u003eEffluents from showers, washing machines and sinks below sewer level\u003c\/li\u003e\n\u003cli\u003eGroundwater lowering applications\u003c\/li\u003e\n\u003cli\u003eDomestic effluents from septic and sludge-treating systems\u003c\/li\u003e\n\u003cli\u003eAgriculture, the dairy industry, horticulture and the process industry\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eOrdering Information\u003c\/div\u003e\n\u003cdiv class=\"gs-lead\"\u003e\n\u003cp\u003eAll three models listed are the manual (M) version and are supplied \u003cstrong\u003ewithout\u003c\/strong\u003e a float switch. For automatic on\/off the pump can be fitted with a float switch, or connected to a separate level switch and control box. Each model ships with 25 ft of cable and a NEMA 5 plug for 115 V service.\u003c\/p\u003e\n\u003cp\u003eOrder by part number: KP 150 — 011DC201; KP 250 — 012DC201; KP 350 — 013DC201.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"gs-note\"\u003e\n\u003cb\u003eBefore You Order\u003c\/b\u003eThese are manual pumps — nothing turns them on and off by itself. If the pump will run unattended in a collecting well, budget for a float switch or a level switch and control box, and allow minimum well dimensions of 14 in across by 16 in deep so a float can swing freely. During operation the inlet strainer must always be completely covered by the liquid, and the pumps are not designed for continuous operation.\u003c\/div\u003e\n\n\u003cdiv class=\"gs-contact\"\u003eFor engineering-led sizing and selection support or a factory submittal, email \u003ca href=\"mailto:sales@watermainsupply.com\"\u003esales@watermainsupply.com\u003c\/a\u003e or call \u003ca href=\"tel:18885104036\"\u003e1-888.510.4036\u003c\/a\u003e.\u003cbr\u003e© Watermain Supply — A division of E4 Industrial LLC\u003c\/div\u003e\n\n\u003c\/div\u003e\n\n\u003ch5\u003eData Sheet\u003c\/h5\u003e\n\u003cdiv class=\"gs\"\u003e\n\u003cdiv class=\"gs-dl\"\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0264\/1913\/4527\/files\/Grundfos_Unilift_KP_Sumbersible_Pump_Datasheet.pdf?v=1788804257\" target=\"_blank\" rel=\"noopener\"\u003eGrundfos Unilift KP Submersible Pump Datasheet\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0264\/1913\/4527\/files\/Unilift__KP_AP_60_US_online.pdf?v=1788804258\" target=\"_blank\" rel=\"noopener\"\u003eUNILIFT KP, AP Data Booklet (60 Hz)\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0264\/1913\/4527\/files\/UNILIFT_AP_APB_APG_CC_KP_Service_Kit_Catalogue.pdf?v=1788804258\" target=\"_blank\" rel=\"noopener\"\u003eUNILIFT AP, APB, APG, CC, KP Service Kit Catalogue\u003c\/a\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003ch5\u003eVideos\u003c\/h5\u003e\n\u003cdiv class=\"gs\"\u003e\u003cdiv class=\"gs-sec\" style=\"margin-top:6px\"\u003e\n\u003cdiv style=\"display:grid;grid-template-columns:repeat(auto-fit,minmax(300px,1fr));gap:18px\"\u003e\n\u003cdiv\u003e\n\u003cdiv style=\"position:relative;padding-bottom:56.25%;height:0;overflow:hidden\"\u003e\u003ciframe src=\"https:\/\/www.youtube.com\/embed\/Xm4G3jbBflQ\" title=\"The Grundfos UNILIFT KP overview\" style=\"position:absolute;top:0;left:0;width:100%;height:100%;border:0\" loading=\"lazy\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share\" allowfullscreen\u003e\u003c\/iframe\u003e\u003c\/div\u003e\n\u003cp style=\"font-size:13px;color:#4A4A4F;margin:8px 0 0\"\u003eThe Grundfos UNILIFT KP overview\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cdiv style=\"position:relative;padding-bottom:56.25%;height:0;overflow:hidden\"\u003e\u003ciframe src=\"https:\/\/www.youtube.com\/embed\/Pv1HVQdNKUg\" title=\"The Grundfos UNILIFT Range\" style=\"position:absolute;top:0;left:0;width:100%;height:100%;border:0\" loading=\"lazy\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share\" allowfullscreen\u003e\u003c\/iframe\u003e\u003c\/div\u003e\n\u003cp style=\"font-size:13px;color:#4A4A4F;margin:8px 0 0\"\u003eThe Grundfos UNILIFT Range\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003c!-- \/TABS --\u003e","brand":"Grundfos","offers":[{"title":"KP 150 - 1\/4 HP 115V 1Ph","offer_id":47456230801583,"sku":"011DC201","price":661.07,"currency_code":"USD","in_stock":true},{"title":"KP 250 - 1\/3 HP 115V 1Ph","offer_id":47456230834351,"sku":"012DC201","price":770.59,"currency_code":"USD","in_stock":true},{"title":"KP 350 - 1\/2 HP 115V 1Ph","offer_id":47456230867119,"sku":"013DC201","price":881.09,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0264\/1913\/4527\/files\/Grundfos_Unilift_KP_2c94c255-8f16-4899-9603-8d68936246b3.webp?v=1788806127","url":"https:\/\/watermainsupply.com\/products\/grundfos-unilift-kp-submersible-pump","provider":"Watermainsupply","version":"1.0","type":"link"}