{"product_id":"grundfos-crne-15-variable-speed-pump-ansi-4000-rpm","title":"Grundfos CRNE 15 Variable-Speed Pump, 2 in ANSI, 4000 rpm","description":"\u003c!-- TABS --\u003e\u003ch5\u003eDescription\u003c\/h5\u003e\u003cdiv class=\"gs\"\u003e\n\u003cdiv class=\"gs-head\"\u003e\n\u003cdiv class=\"gs-eyebrow\"\u003eGRUNDFOS · VARIABLE-SPEED VERTICAL MULTISTAGE PUMP\u003c\/div\u003e\n\u003cdiv class=\"gs-title\"\u003eCRNE 15 — 2 in ANSI, 4000 rpm\u003c\/div\u003e\n\u003cdiv class=\"gs-sub\"\u003eVariable-speed vertical multistage centrifugal pump in 316 stainless steel with a Grundfos MLE motor and built-in frequency converter. 8 models from CRNE 15-1 to CRNE 15-10, 2 to 25 HP, 2 in ANSI ports, 4000 rpm version, with or without a factory pressure sensor.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"gs-badges\"\u003e\n\u003cdiv class=\"gs-badge\" style=\"background:#B3122A;color:#FFFFFF;border-color:#B3122A\"\u003e81-836 ft (35-362 PSI) Max Head · 122-142 GPM Max\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003e2-25 HP\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003e200-240V 1Ph (2 HP) · 200-240V 3Ph · 440-480V 3Ph\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003e2 in ANSI Ports\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003eIn-Line Suction and Discharge\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003eGrundfos MLE Motor, Built-In Drive\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003eUp to 4000 rpm\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003e363 PSI Max Operating Pressure\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003eNSF\/ANSI 61\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003e95-329 lb Weight\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eOverview\u003c\/div\u003e\n\u003cdiv class=\"gs-lead\"\u003e\n\u003cp\u003eThe CRNE 15 is the CRN 15 pump end on a Grundfos MLE motor with the frequency converter built in, so the pump varies its own speed to hold a setpoint instead of running flat out against a throttled valve. Every part in contact with the liquid is high-grade stainless steel (EN 1.4401, AISI 316). This listing is the 4000 rpm version with 2 in ANSI connections; Grundfos sells the 4000 rpm and 3600 rpm versions as separate part numbers with different curves, so each is listed on its own. The Grundfos nominal duty is 92.2 to 109 GPM by model at full speed; size it from the performance table below.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e8 models, CRNE 15-1 to CRNE 15-10, 2 to 25 HP; some models are offered on two motor sizes, and the larger motor holds the full-speed curve further out\u003c\/li\u003e\n\u003cli\u003eSupply: 200-240V 1Ph (2 HP), 200-240V 3Ph, 440-480V 3Ph\u003c\/li\u003e\n\u003cli\u003eEvery model with or without a pressure sensor; sensor range 0-145 psi, 0-232 psi, 0-362 psi, 0-580 psi by model\u003c\/li\u003e\n\u003cli\u003e2 in ANSI flanges\u003c\/li\u003e\n\u003cli\u003eMLE motor: IE5 efficiency class, IP55, speed range 360 rpm to rated speed, graphical control panel; HQQE (EPDM) cartridge shaft seal\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background:#FFFFFF;border:1px solid #C7CBD1;border-top:3px solid #B3122A;padding:12px 16px 12px;margin:16px 0 4px;font-size:13.5px;line-height:1.55;color:#4A4A4F\"\u003e\n\u003cdiv style=\"font-family:Arial Black,Arial,sans-serif;font-size:11px;letter-spacing:1.2px;text-transform:uppercase;color:#B3122A;margin-bottom:8px\"\u003eWhat Ships and What It Needs to Run\u003c\/div\u003e\n\u003cp style=\"margin:0 0 6px\"\u003e\u003cstrong style=\"color:#B3122A\"\u003eIncluded:\u003c\/strong\u003e the CRNE 15 pump end and its Grundfos MLE motor with built-in frequency converter, factory-assembled as one complete pump. With-sensor versions come with a pressure sensor in the range shown for the model.\u003c\/p\u003e\n\u003cp style=\"margin:0 0 6px\"\u003e\u003cstrong style=\"color:#B3122A\"\u003eANSI companion flanges required, ordered separately.\u003c\/strong\u003e Grundfos supplies the companion connection as a separate flange set: two flanges, two gaskets, nuts and bolts, sized 2 in.\u003c\/p\u003e\n\u003cp style=\"margin:0 0 6px\"\u003e\u003cstrong style=\"color:#B3122A\"\u003eWithout-sensor versions:\u003c\/strong\u003e for constant-pressure control, add a sensor or an external control signal.\u003c\/p\u003e\n\u003cp style=\"margin:0\"\u003e\u003cstrong style=\"color:#B3122A\"\u003eSuction and discharge piping, valves, power supply and disconnect:\u003c\/strong\u003e sized to your system and ordered separately.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background:#E1E3E6;border-left:3px solid #B8BDC4;padding:8px 14px;font-size:11.5px;color:#4A4A4F;margin-top:14px;line-height:1.5\"\u003eGenuine Grundfos equipment, factory-new in original packaging — sold and supported by Watermain Supply, an independent industrial supplier.\u003c\/div\u003e\n\u003cdiv style=\"border:1px solid #C7CBD1;border-left:3px solid #B3122A;padding:10px 14px;margin:14px 0 4px;font-size:13.5px;line-height:1.55;color:#4A4A4F\"\u003e\n\u003cstrong style=\"color:#B3122A\"\u003eWarranty:\u003c\/strong\u003e 24 months from date of installation, but not more than 30 months from date of manufacture (Grundfos limited warranty). Grundfos repairs or replaces its own product; costs of removal, installation and transportation are not covered, and products sold but not manufactured by Grundfos carry their own manufacturer’s warranty.\u003c\/div\u003e\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eSpecifications\u003c\/div\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal flow at full speed\u003c\/td\u003e\n\u003ctd\u003e92.2 to 109 GPM by model (Grundfos nominal duty)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShut-off head range at full speed\u003c\/td\u003e\n\u003ctd\u003e81 to 836 ft (35 to 362 PSI)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor power range\u003c\/td\u003e\n\u003ctd\u003e2 to 25 HP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply\u003c\/td\u003e\n\u003ctd\u003e200-240V 1Ph (2 HP); 200-240V 3Ph; 440-480V 3Ph\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor\u003c\/td\u003e\n\u003ctd\u003eGrundfos MLE, permanent-magnet, built-in frequency converter, IE5, IP55\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpeed\u003c\/td\u003e\n\u003ctd\u003e360 rpm to 4000 rpm (4000 rpm version)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNEMA frames\u003c\/td\u003e\n\u003ctd\u003e56C, 182TC, 213TC, 254TC, 284TC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency\u003c\/td\u003e\n\u003ctd\u003e60 Hz supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure sensor\u003c\/td\u003e\n\u003ctd\u003eWith-sensor versions: 0-145 psi, 0-232 psi, 0-362 psi, 0-580 psi by model; without-sensor versions have none\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSuction and discharge ports\u003c\/td\u003e\n\u003ctd\u003e2 in ANSI, in-line\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnections\u003c\/td\u003e\n\u003ctd\u003e2 in ANSI flanges, 300 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum operating pressure\u003c\/td\u003e\n\u003ctd\u003e363 PSI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShaft seal\u003c\/td\u003e\n\u003ctd\u003eHQQE (EPDM), the Grundfos standard on these pumps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLiquid temperature\u003c\/td\u003e\n\u003ctd\u003e−4 °F to 248 °F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum ambient temperature\u003c\/td\u003e\n\u003ctd\u003e122 °F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePump orientation\u003c\/td\u003e\n\u003ctd\u003eVertical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApprovals\u003c\/td\u003e\n\u003ctd\u003eNSF\/ANSI 61 drinking water (Grundfos product data)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eModels \u0026amp; Performance — Will It Do What You Need?\u003c\/div\u003e\n\u003cp style=\"font-size:13.5px;margin-bottom:10px\"\u003eFind the pressure you need at your flow and pick the first model that reaches it at full speed; the drive then slows the pump to hold your setpoint. Pressure at flow in PSI, one row per model and motor.\u003c\/p\u003e\n\u003cdetails open style=\"margin:0 0 10px\"\u003e\u003csummary style=\"cursor:pointer;font-weight:600;margin-bottom:8px\"\u003eCRNE 15-1 to CRNE 15-10 · 12 curves\u003c\/summary\u003e\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eModel (HP)\u003c\/th\u003e\n\u003cth\u003e0 GPM (Shut-off)\u003c\/th\u003e\n\u003cth\u003e24 GPM\u003c\/th\u003e\n\u003cth\u003e60 GPM\u003c\/th\u003e\n\u003cth\u003e90 GPM\u003c\/th\u003e\n\u003cth\u003e120 GPM\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eCRNE 15-1 (2 HP)\u003c\/td\u003e\n\u003ctd\u003e35\u003c\/td\u003e\n\u003ctd\u003e34\u003c\/td\u003e\n\u003ctd\u003e32\u003c\/td\u003e\n\u003ctd\u003e25\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCRNE 15-1 (3 HP)\u003c\/td\u003e\n\u003ctd\u003e35\u003c\/td\u003e\n\u003ctd\u003e34\u003c\/td\u003e\n\u003ctd\u003e32\u003c\/td\u003e\n\u003ctd\u003e29\u003c\/td\u003e\n\u003ctd\u003e23\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCRNE 15-2 (5 HP)\u003c\/td\u003e\n\u003ctd\u003e71\u003c\/td\u003e\n\u003ctd\u003e70\u003c\/td\u003e\n\u003ctd\u003e67\u003c\/td\u003e\n\u003ctd\u003e60\u003c\/td\u003e\n\u003ctd\u003e48\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCRNE 15-3 (7 1\/2 HP)\u003c\/td\u003e\n\u003ctd\u003e109\u003c\/td\u003e\n\u003ctd\u003e106\u003c\/td\u003e\n\u003ctd\u003e102\u003c\/td\u003e\n\u003ctd\u003e93\u003c\/td\u003e\n\u003ctd\u003e75\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCRNE 15-4 (7 1\/2 HP)\u003c\/td\u003e\n\u003ctd\u003e145\u003c\/td\u003e\n\u003ctd\u003e142\u003c\/td\u003e\n\u003ctd\u003e127\u003c\/td\u003e\n\u003ctd\u003e94\u003c\/td\u003e\n\u003ctd\u003e62\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCRNE 15-4 (10 HP)\u003c\/td\u003e\n\u003ctd\u003e145\u003c\/td\u003e\n\u003ctd\u003e142\u003c\/td\u003e\n\u003ctd\u003e137\u003c\/td\u003e\n\u003ctd\u003e125\u003c\/td\u003e\n\u003ctd\u003e94\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCRNE 15-5 (10 HP)\u003c\/td\u003e\n\u003ctd\u003e181\u003c\/td\u003e\n\u003ctd\u003e177\u003c\/td\u003e\n\u003ctd\u003e171\u003c\/td\u003e\n\u003ctd\u003e139\u003c\/td\u003e\n\u003ctd\u003e99\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCRNE 15-6 (15 HP)\u003c\/td\u003e\n\u003ctd\u003e217\u003c\/td\u003e\n\u003ctd\u003e214\u003c\/td\u003e\n\u003ctd\u003e207\u003c\/td\u003e\n\u003ctd\u003e188\u003c\/td\u003e\n\u003ctd\u003e152\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCRNE 15-8 (15 HP)\u003c\/td\u003e\n\u003ctd\u003e290\u003c\/td\u003e\n\u003ctd\u003e285\u003c\/td\u003e\n\u003ctd\u003e273\u003c\/td\u003e\n\u003ctd\u003e207\u003c\/td\u003e\n\u003ctd\u003e147\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCRNE 15-8 (20 HP)\u003c\/td\u003e\n\u003ctd\u003e290\u003c\/td\u003e\n\u003ctd\u003e285\u003c\/td\u003e\n\u003ctd\u003e277\u003c\/td\u003e\n\u003ctd\u003e253\u003c\/td\u003e\n\u003ctd\u003e209\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCRNE 15-10 (20 HP)\u003c\/td\u003e\n\u003ctd\u003e362\u003c\/td\u003e\n\u003ctd\u003e357\u003c\/td\u003e\n\u003ctd\u003e347\u003c\/td\u003e\n\u003ctd\u003e281\u003c\/td\u003e\n\u003ctd\u003e203\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCRNE 15-10 (25 HP)\u003c\/td\u003e\n\u003ctd\u003e362\u003c\/td\u003e\n\u003ctd\u003e357\u003c\/td\u003e\n\u003ctd\u003e347\u003c\/td\u003e\n\u003ctd\u003e317\u003c\/td\u003e\n\u003ctd\u003e258\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cp style=\"font-size:12.5px;color:#9B9EA3;margin-top:8px;line-height:1.55\"\u003ePressure the pump develops at full speed (4000 rpm version) at each flow, in PSI, rounded down (feet = PSI × 2.31). Shut-off is Grundfos’s published maximum head. Flow columns are read from the 100% speed curve on the Grundfos 60 Hz chart for each model and motor (water at 68 °F), digitized and rounded down, at 20%, 50% and 75% of 120 GPM, the last regular flow every curve in this listing reaches; the curves end at 122 to 142 GPM. Where a model is offered on two motor sizes, the smaller motor reaches its power limit sooner and its curve falls away at high flow. At reduced speed the pump runs on a lower curve; full Grundfos charts with the reduced-speed curves are in the product images. Grundfos’s published duty point sits above its own curve by more than 3% of shut-off on CRNE 15-10 (20 HP), CRNE 15-8 (15 HP), CRNE 15-5 (10 HP), CRNE 15-4 (7 1\/2 HP), CRNE 15-1 (2 HP) (by up to 70 ft at the rated flow), where the motor’s power limit cuts the curve; the table follows the curve.\u003c\/p\u003e\n\u003cdiv style=\"display:flex;flex-wrap:wrap;gap:10px;margin:22px 0 4px\"\u003e\n\u003ca href=\"\/pages\/well-irrigation-pump-sizing-calculator\" style=\"flex:1 1 200px;text-align:center;display:block;background:#B3122A;color:#ffffff;font-family:Arial Black,Arial,sans-serif;font-size:12px;text-transform:uppercase;letter-spacing:1.2px;padding:11px 18px;text-decoration:none\"\u003eWell \u0026amp; Irrigation Calculator\u003c\/a\u003e\u003ca href=\"\/pages\/pressure-tank-sizing-calculator\" style=\"flex:1 1 200px;text-align:center;display:block;background:#B3122A;color:#ffffff;font-family:Arial Black,Arial,sans-serif;font-size:12px;text-transform:uppercase;letter-spacing:1.2px;padding:11px 18px;text-decoration:none\"\u003eTank Calculator\u003c\/a\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eBefore You Buy — The Limits That Decide the Fit\u003c\/div\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eCheck\u003c\/th\u003e\n\u003cth\u003eWhat decides the fit\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eDuty point\u003c\/td\u003e\n\u003ctd\u003eThe model’s full-speed pressure at your flow must cover the system’s total head; shut-off is the most it can make, at zero flow.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWorking pressure\u003c\/td\u003e\n\u003ctd\u003eInlet pressure plus the pressure the pump adds must stay within the maximum operating pressure: 363 PSI.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensor\u003c\/td\u003e\n\u003ctd\u003eFor constant-pressure control order the with-sensor version, and pick a sensor range above your setpoint; without-sensor versions need a sensor or external control signal for that.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower\u003c\/td\u003e\n\u003ctd\u003eSupply at the voltage and phase shown in the selected option; the drive is inside the motor, so no separate VFD is needed.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnections\u003c\/td\u003e\n\u003ctd\u003eANSI companion flanges (2 in) ordered separately.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLiquid temperature\u003c\/td\u003e\n\u003ctd\u003e−4 °F to 248 °F, HQQE (EPDM) shaft seal.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eApplications\u003c\/div\u003e\n\u003cdiv class=\"gs-lead\"\u003e\u003cp\u003eConstant-pressure water supply and boosting, HVAC heating and cooling circulation, industrial water supply and transfer, process liquids, wash and clean, water treatment and irrigation (Grundfos CR range applications).\u003c\/p\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eMaterials of Construction\u003c\/div\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eComponent\u003c\/th\u003e\n\u003cth\u003eMaterial\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAll wetted parts\u003c\/td\u003e\n\u003ctd\u003eStainless steel EN 1.4401 (AISI 316)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlange rings and base plate (ANSI versions)\u003c\/td\u003e\n\u003ctd\u003eCast iron, not in contact with the pumped liquid\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eImpellers\u003c\/td\u003e\n\u003ctd\u003eStainless steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBearings\u003c\/td\u003e\n\u003ctd\u003eSilicon carbide\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShaft seal\u003c\/td\u003e\n\u003ctd\u003eHQQE cartridge seal, silicon carbide faces, EPDM rubber\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"gs-contact\"\u003eFor engineering-led sizing and selection support or a factory submittal, email \u003ca href=\"mailto:sales@watermainsupply.com\"\u003esales@watermainsupply.com\u003c\/a\u003e or call \u003ca href=\"tel:18885104036\"\u003e1-888.510.4036\u003c\/a\u003e.\u003cbr\u003e© Watermain Supply — A division of E4 Industrial LLC\u003c\/div\u003e\n\u003c\/div\u003e\u003ch5\u003eData Sheet\u003c\/h5\u003e\u003cdiv class=\"gs\"\u003e\u003cdiv class=\"gs-dl\"\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0264\/1913\/4527\/files\/98358864_06_2026_CRE__CRIE__CRNE__SPKE__MTRE__MTHE__CME_IO_en-GB_online.pdf?v=1789451710\" target=\"_blank\" rel=\"noopener\"\u003eCRE, CRIE, CRNE Installation and Operating Instructions\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0264\/1913\/4527\/files\/99689406_09.2024_Data_sheet_MLE_online.pdf?v=1789451709\" target=\"_blank\" rel=\"noopener\"\u003eGrundfos MLE Motor Data Sheet\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0264\/1913\/4527\/files\/98446676_07_2026_CR_1-64_DB_NEMA_English_online.pdf?v=1792001201\" target=\"_blank\" rel=\"noopener\"\u003eCR, CRI, CRN 1-64 Data Booklet (60 Hz, NEMA, 2026)\u003c\/a\u003e\n\u003c\/div\u003e\u003c\/div\u003e\u003ch5\u003eVideos\u003c\/h5\u003e\u003cdiv class=\"gs\"\u003e\u003cp style=\"color:#9B9EA3;font-size:13px\"\u003eVideos for this product are being added.\u003c\/p\u003e\u003c\/div\u003e\u003c!-- \/TABS --\u003e","brand":"Grundfos","offers":[{"title":"2 HP - 200-240V 1Ph \/ With Sensor \/ CRNE 15-1 - 35 PSI Max, 128 GPM Max","offer_id":50763547508911,"sku":"93287646","price":7107.37,"currency_code":"USD","in_stock":true},{"title":"2 HP - 200-240V 1Ph \/ Without Sensor \/ CRNE 15-1 - 35 PSI Max, 128 GPM Max","offer_id":50763547541679,"sku":"93287639","price":6725.61,"currency_code":"USD","in_stock":true},{"title":"2 HP - 200-240V 3Ph \/ With Sensor \/ CRNE 15-1 - 35 PSI Max, 128 GPM Max","offer_id":50763547574447,"sku":"93288748","price":7522.11,"currency_code":"USD","in_stock":true},{"title":"2 HP - 200-240V 3Ph \/ Without Sensor \/ CRNE 15-1 - 35 PSI Max, 128 GPM Max","offer_id":50763547607215,"sku":"93288700","price":7140.35,"currency_code":"USD","in_stock":true},{"title":"2 HP - 440-480V 3Ph \/ With Sensor \/ CRNE 15-1 - 35 PSI Max, 128 GPM Max","offer_id":50763547639983,"sku":"93288368","price":7522.11,"currency_code":"USD","in_stock":true},{"title":"2 HP - 440-480V 3Ph \/ Without Sensor \/ CRNE 15-1 - 35 PSI Max, 128 GPM Max","offer_id":50763547672751,"sku":"93288242","price":7140.35,"currency_code":"USD","in_stock":true},{"title":"3 HP - 200-240V 3Ph \/ With Sensor \/ CRNE 15-1 - 35 PSI Max, 142 GPM Max","offer_id":50763547705519,"sku":"93288749","price":7894.04,"currency_code":"USD","in_stock":true},{"title":"3 HP - 200-240V 3Ph \/ Without Sensor \/ CRNE 15-1 - 35 PSI Max, 142 GPM Max","offer_id":50763547738287,"sku":"93288701","price":7512.98,"currency_code":"USD","in_stock":true},{"title":"3 HP - 440-480V 3Ph \/ With Sensor \/ CRNE 15-1 - 35 PSI Max, 142 GPM Max","offer_id":50763547771055,"sku":"93288369","price":7894.04,"currency_code":"USD","in_stock":true},{"title":"3 HP - 440-480V 3Ph \/ Without Sensor \/ CRNE 15-1 - 35 PSI Max, 142 GPM Max","offer_id":50763547803823,"sku":"93288245","price":7512.98,"currency_code":"USD","in_stock":true},{"title":"5 HP - 200-240V 3Ph \/ With Sensor \/ CRNE 15-2 - 71 PSI Max, 139 GPM Max","offer_id":50763547836591,"sku":"93288750","price":8885.61,"currency_code":"USD","in_stock":true},{"title":"5 HP - 200-240V 3Ph \/ Without Sensor \/ CRNE 15-2 - 71 PSI Max, 139 GPM Max","offer_id":50763547869359,"sku":"93288702","price":8503.86,"currency_code":"USD","in_stock":true},{"title":"5 HP - 440-480V 3Ph \/ With Sensor \/ CRNE 15-2 - 71 PSI Max, 139 GPM Max","offer_id":50763547902127,"sku":"93288370","price":8938.25,"currency_code":"USD","in_stock":true},{"title":"5 HP - 440-480V 3Ph \/ Without Sensor \/ CRNE 15-2 - 71 PSI Max, 139 GPM Max","offer_id":50763547934895,"sku":"93288247","price":8556.49,"currency_code":"USD","in_stock":true},{"title":"7 1\/2 HP - 200-240V 3Ph \/ With Sensor \/ CRNE 15-3 - 109 PSI Max, 139 GPM Max","offer_id":50763547967663,"sku":"93288751","price":10157.19,"currency_code":"USD","in_stock":true},{"title":"7 1\/2 HP - 200-240V 3Ph \/ With Sensor \/ CRNE 15-4 - 145 PSI Max, 122 GPM Max","offer_id":50763548000431,"sku":"93288752","price":10543.16,"currency_code":"USD","in_stock":true},{"title":"7 1\/2 HP - 200-240V 3Ph \/ Without Sensor \/ CRNE 15-3 - 109 PSI Max, 139 GPM Max","offer_id":50763548033199,"sku":"93288703","price":9776.14,"currency_code":"USD","in_stock":true},{"title":"7 1\/2 HP - 200-240V 3Ph \/ Without Sensor \/ CRNE 15-4 - 145 PSI Max, 122 GPM Max","offer_id":50763548065967,"sku":"93288704","price":10162.11,"currency_code":"USD","in_stock":true},{"title":"7 1\/2 HP - 440-480V 3Ph \/ With Sensor \/ CRNE 15-3 - 109 PSI Max, 139 GPM Max","offer_id":50763548098735,"sku":"93288372","price":10157.19,"currency_code":"USD","in_stock":true},{"title":"7 1\/2 HP - 440-480V 3Ph \/ With Sensor \/ CRNE 15-4 - 145 PSI Max, 122 GPM Max","offer_id":50763548131503,"sku":"93288373","price":10543.16,"currency_code":"USD","in_stock":true},{"title":"7 1\/2 HP - 440-480V 3Ph \/ Without Sensor \/ CRNE 15-3 - 109 PSI Max, 139 GPM Max","offer_id":50763548164271,"sku":"93288260","price":9776.14,"currency_code":"USD","in_stock":true},{"title":"7 1\/2 HP - 440-480V 3Ph \/ Without Sensor \/ CRNE 15-4 - 145 PSI Max, 122 GPM Max","offer_id":50763548197039,"sku":"93288261","price":10162.11,"currency_code":"USD","in_stock":true},{"title":"10 HP - 200-240V 3Ph \/ With Sensor \/ CRNE 15-4 - 145 PSI Max, 136 GPM Max","offer_id":50763548229807,"sku":"93291810","price":11148.07,"currency_code":"USD","in_stock":true},{"title":"10 HP - 200-240V 3Ph \/ With Sensor \/ CRNE 15-5 - 181 PSI Max, 130 GPM Max","offer_id":50763548262575,"sku":"93291811","price":11423.86,"currency_code":"USD","in_stock":true},{"title":"10 HP - 200-240V 3Ph \/ Without Sensor \/ CRNE 15-4 - 145 PSI Max, 136 GPM Max","offer_id":50763548295343,"sku":"93291774","price":10767.02,"currency_code":"USD","in_stock":true},{"title":"10 HP - 200-240V 3Ph \/ Without Sensor \/ CRNE 15-5 - 181 PSI Max, 130 GPM Max","offer_id":50763548328111,"sku":"93291776","price":11042.81,"currency_code":"USD","in_stock":true},{"title":"10 HP - 440-480V 3Ph \/ With Sensor \/ CRNE 15-4 - 145 PSI Max, 136 GPM Max","offer_id":50763548360879,"sku":"93288374","price":11148.07,"currency_code":"USD","in_stock":true},{"title":"10 HP - 440-480V 3Ph \/ With Sensor \/ CRNE 15-5 - 181 PSI Max, 130 GPM Max","offer_id":50763548393647,"sku":"93288375","price":11423.86,"currency_code":"USD","in_stock":true},{"title":"10 HP - 440-480V 3Ph \/ Without Sensor \/ CRNE 15-4 - 145 PSI Max, 136 GPM Max","offer_id":50763548426415,"sku":"93288262","price":10767.02,"currency_code":"USD","in_stock":true},{"title":"10 HP - 440-480V 3Ph \/ Without Sensor \/ CRNE 15-5 - 181 PSI Max, 130 GPM Max","offer_id":50763548459183,"sku":"93288263","price":11042.81,"currency_code":"USD","in_stock":true},{"title":"15 HP - 200-240V 3Ph \/ With Sensor \/ CRNE 15-6 - 217 PSI Max, 140 GPM Max","offer_id":50763548491951,"sku":"93291812","price":12831.58,"currency_code":"USD","in_stock":true},{"title":"15 HP - 200-240V 3Ph \/ With Sensor \/ CRNE 15-8 - 290 PSI Max, 127 GPM Max","offer_id":50763548524719,"sku":"93291813","price":14230.18,"currency_code":"USD","in_stock":true},{"title":"15 HP - 200-240V 3Ph \/ Without Sensor \/ CRNE 15-6 - 217 PSI Max, 140 GPM Max","offer_id":50763548557487,"sku":"93291777","price":12450.53,"currency_code":"USD","in_stock":true},{"title":"15 HP - 200-240V 3Ph \/ Without Sensor \/ CRNE 15-8 - 290 PSI Max, 127 GPM Max","offer_id":50763548590255,"sku":"93291778","price":13848.42,"currency_code":"USD","in_stock":true},{"title":"15 HP - 440-480V 3Ph \/ With Sensor \/ CRNE 15-6 - 217 PSI Max, 140 GPM Max","offer_id":50763548623023,"sku":"93288376","price":12831.58,"currency_code":"USD","in_stock":true},{"title":"15 HP - 440-480V 3Ph \/ With Sensor \/ CRNE 15-8 - 290 PSI Max, 127 GPM Max","offer_id":50763548655791,"sku":"93288377","price":14230.18,"currency_code":"USD","in_stock":true},{"title":"15 HP - 440-480V 3Ph \/ Without Sensor \/ CRNE 15-6 - 217 PSI Max, 140 GPM Max","offer_id":50763548688559,"sku":"93288264","price":12450.53,"currency_code":"USD","in_stock":true},{"title":"15 HP - 440-480V 3Ph \/ Without Sensor \/ CRNE 15-8 - 290 PSI Max, 127 GPM Max","offer_id":50763548721327,"sku":"93288265","price":13848.42,"currency_code":"USD","in_stock":true},{"title":"20 HP - 440-480V 3Ph \/ With Sensor \/ CRNE 15-8 - 290 PSI Max, 141 GPM Max","offer_id":50763548754095,"sku":"93288379","price":15404.91,"currency_code":"USD","in_stock":true},{"title":"20 HP - 440-480V 3Ph \/ With Sensor \/ CRNE 15-10 - 362 PSI Max, 131 GPM Max","offer_id":50763548786863,"sku":"93288381","price":17345.26,"currency_code":"USD","in_stock":true},{"title":"20 HP - 440-480V 3Ph \/ Without Sensor \/ CRNE 15-8 - 290 PSI Max, 141 GPM Max","offer_id":50763548819631,"sku":"93288269","price":15023.16,"currency_code":"USD","in_stock":true},{"title":"20 HP - 440-480V 3Ph \/ Without Sensor \/ CRNE 15-10 - 362 PSI Max, 131 GPM Max","offer_id":50763548852399,"sku":"93288273","price":16964.21,"currency_code":"USD","in_stock":true},{"title":"25 HP - 440-480V 3Ph \/ With Sensor \/ CRNE 15-10 - 362 PSI Max, 140 GPM Max","offer_id":50763548885167,"sku":"93288383","price":18663.86,"currency_code":"USD","in_stock":true},{"title":"25 HP - 440-480V 3Ph \/ Without Sensor \/ CRNE 15-10 - 362 PSI Max, 140 GPM Max","offer_id":50763548917935,"sku":"93288276","price":18282.81,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0264\/1913\/4527\/files\/Grundfos_CRNE_15_ANSI_Variable_Speed_Pump_cd070be5-0e62-498e-b2d9-e3018040a81a.png?v=1793046623","url":"https:\/\/watermainsupply.com\/products\/grundfos-crne-15-variable-speed-pump-ansi-4000-rpm","provider":"Watermainsupply","version":"1.0","type":"link"}