{"product_id":"grundfos-cm-10-g-horizontal-multistage-pump","title":"Grundfos CM 10-G Horizontal Multistage Pump, 316 Stainless Steel","description":"\u003c!-- TABS --\u003e\u003ch5\u003eDescription\u003c\/h5\u003e\u003cdiv class=\"gs\"\u003e\n\u003cdiv class=\"gs-head\"\u003e\n\u003cdiv class=\"gs-eyebrow\"\u003eGRUNDFOS · HORIZONTAL MULTISTAGE CENTRIFUGAL PUMP\u003c\/div\u003e\n\u003cdiv class=\"gs-title\"\u003eCM 10-G — 316 Stainless Steel\u003c\/div\u003e\n\u003cdiv class=\"gs-sub\"\u003eHorizontal, close-coupled, end-suction multistage centrifugal pump. 52.8 GPM rated flow at 60 Hz, 5 models from CM 10-1 to CM 10-5, 1.5 to 8.4 HP, AQQE or AQQV shaft seal.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"gs-badges\"\u003e\n\u003cdiv class=\"gs-badge\"\u003e52.8 GPM Rated Flow\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003e53-306 ft Rated Head\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003e1.5 to 8.4 HP\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003e232 psi Max Pressure\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003e316 Stainless Steel\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eOverview\u003c\/div\u003e\n\u003cdiv class=\"gs-lead\"\u003e\n\u003cp\u003eHorizontal, multistage centrifugal pump with the motor close-coupled to the pump end and the suction port on the end of the pump. Unlike the vertical CR range, the CM sits on its feet on a horizontal base, which suits a plant room where headroom is short and floor space is not.\u003c\/p\u003e\n\u003cp\u003eThe CM 10 frame is rated at 52.8 GPM. The family number is Grundfos’s nominal duty in cubic metres per hour, not a GPM figure — size the pump from the rated head table below, not from the model number.\u003c\/p\u003e\n\u003cp\u003e5 models are offered, from CM 10-1 to CM 10-5, covering 1.5 to 8.4 HP on NEMA close-coupled motors. Adding stages raises head at the same flow without changing the footprint. Connections are 1-1\/2 in NPT female suction and discharge, and the pump is rated 232 psi maximum operating pressure.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhy 316 rather than 304.\u003c\/strong\u003e The hydraulics are identical: Grundfos publishes the same rated head for the -I and -G builds of every model. What changes is corrosion resistance. The molybdenum in AISI 316 resists chloride pitting, which 304 does not, so the -G build is the grade for softened, brackish and chloride-bearing water. Where chlorides are not the issue, the -I build does the same hydraulic job for less.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background:#E1E3E6;border-left:3px solid #B8BDC4;padding:8px 14px;font-size:11.5px;color:#4A4A4F;margin-top:14px;line-height:1.5\"\u003eGenuine Grundfos equipment, factory-new in original packaging — sold and supported by Watermain Supply, an independent industrial supplier.\u003c\/div\u003e\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003ePerformance — Will It Do What You Need?\u003c\/div\u003e\n\u003cp style=\"font-size:13.5px;margin-bottom:10px\"\u003eFind the \u003cstrong\u003ehead you need in feet\u003c\/strong\u003e and pick the model that meets it at 52.8 GPM. Head is what the pump \u003cstrong\u003eadds\u003c\/strong\u003e to the pressure already at its inlet, not the pressure you will read at the outlet.\u003c\/p\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003cth\u003eHP\u003c\/th\u003e\n\u003cth\u003eRated flow - GPM\u003c\/th\u003e\n\u003cth\u003eRated head - ft\u003c\/th\u003e\n\u003cth\u003eRated head - m\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eCM 10-1\u003c\/td\u003e\n\u003ctd\u003e1.5\u003c\/td\u003e\n\u003ctd\u003e52.8\u003c\/td\u003e\n\u003ctd\u003e53\u003c\/td\u003e\n\u003ctd\u003e16.12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCM 10-2\u003c\/td\u003e\n\u003ctd\u003e3.4\u003c\/td\u003e\n\u003ctd\u003e52.8\u003c\/td\u003e\n\u003ctd\u003e116\u003c\/td\u003e\n\u003ctd\u003e35.44\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCM 10-3\u003c\/td\u003e\n\u003ctd\u003e5.4\u003c\/td\u003e\n\u003ctd\u003e52.8\u003c\/td\u003e\n\u003ctd\u003e180\u003c\/td\u003e\n\u003ctd\u003e54.77\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCM 10-4\u003c\/td\u003e\n\u003ctd\u003e8.4\u003c\/td\u003e\n\u003ctd\u003e52.8\u003c\/td\u003e\n\u003ctd\u003e243\u003c\/td\u003e\n\u003ctd\u003e74.09\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCM 10-5\u003c\/td\u003e\n\u003ctd\u003e8.4\u003c\/td\u003e\n\u003ctd\u003e52.8\u003c\/td\u003e\n\u003ctd\u003e306\u003c\/td\u003e\n\u003ctd\u003e93.42\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"font-size:12.5px;color:#9B9EA3;margin-top:8px;line-height:1.55\"\u003eFigures are Grundfos published data for 60 Hz at the rated duty point, based on a pump speed of 3480 rpm. Divide feet by 2.31 for psi; elevation costs 0.433 psi per foot of lift. Grundfos Product Center publishes no page for CM 10-4 and CM 10-5 in this material, so the head shown for those models is the figure published for the AISI 304 build, which is identical on every model where Grundfos publishes both. For a duty between two models, or for flows away from 52.8 GPM, ask us to size it against the published curve.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eModels, Voltage \u0026amp; Phase\u003c\/div\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003cth\u003eHP\u003c\/th\u003e\n\u003cth\u003eVoltage \u0026amp; Phase\u003c\/th\u003e\n\u003cth\u003eSeal\u003c\/th\u003e\n\u003cth\u003ePart No.\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eCM 10-1\u003c\/td\u003e\n\u003ctd\u003e1.5\u003c\/td\u003e\n\u003ctd\u003e115\/230V 1Ph\u003c\/td\u003e\n\u003ctd\u003eAQQE\u003c\/td\u003e\n\u003ctd\u003e96943188\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCM 10-1\u003c\/td\u003e\n\u003ctd\u003e1.5\u003c\/td\u003e\n\u003ctd\u003e115\/230V 1Ph\u003c\/td\u003e\n\u003ctd\u003eAQQV\u003c\/td\u003e\n\u003ctd\u003e96943191\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCM 10-1\u003c\/td\u003e\n\u003ctd\u003e1.5\u003c\/td\u003e\n\u003ctd\u003e208-230\/440-480V 3Ph\u003c\/td\u003e\n\u003ctd\u003eAQQE\u003c\/td\u003e\n\u003ctd\u003e99155409\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCM 10-1\u003c\/td\u003e\n\u003ctd\u003e1.5\u003c\/td\u003e\n\u003ctd\u003e208-230\/440-480V 3Ph\u003c\/td\u003e\n\u003ctd\u003eAQQV\u003c\/td\u003e\n\u003ctd\u003e99155419\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCM 10-2\u003c\/td\u003e\n\u003ctd\u003e3.4\u003c\/td\u003e\n\u003ctd\u003e208-230\/440-480V 3Ph\u003c\/td\u003e\n\u003ctd\u003eAQQE\u003c\/td\u003e\n\u003ctd\u003e96943243\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCM 10-2\u003c\/td\u003e\n\u003ctd\u003e3.4\u003c\/td\u003e\n\u003ctd\u003e208-230\/440-480V 3Ph\u003c\/td\u003e\n\u003ctd\u003eAQQV\u003c\/td\u003e\n\u003ctd\u003e96806991\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCM 10-3\u003c\/td\u003e\n\u003ctd\u003e5.4\u003c\/td\u003e\n\u003ctd\u003e208-230\/440-480V 3Ph\u003c\/td\u003e\n\u003ctd\u003eAQQE\u003c\/td\u003e\n\u003ctd\u003e97568507\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCM 10-3\u003c\/td\u003e\n\u003ctd\u003e5.4\u003c\/td\u003e\n\u003ctd\u003e208-230\/440-480V 3Ph\u003c\/td\u003e\n\u003ctd\u003eAQQV\u003c\/td\u003e\n\u003ctd\u003e96806993\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCM 10-4\u003c\/td\u003e\n\u003ctd\u003e8.4\u003c\/td\u003e\n\u003ctd\u003e208-230\/440-480V 3Ph\u003c\/td\u003e\n\u003ctd\u003eAQQE\u003c\/td\u003e\n\u003ctd\u003e99311046\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCM 10-4\u003c\/td\u003e\n\u003ctd\u003e8.4\u003c\/td\u003e\n\u003ctd\u003e208-230\/440-480V 3Ph\u003c\/td\u003e\n\u003ctd\u003eAQQV\u003c\/td\u003e\n\u003ctd\u003e99311107\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCM 10-5\u003c\/td\u003e\n\u003ctd\u003e8.4\u003c\/td\u003e\n\u003ctd\u003e208-230\/440-480V 3Ph\u003c\/td\u003e\n\u003ctd\u003eAQQE\u003c\/td\u003e\n\u003ctd\u003e99327174\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCM 10-5\u003c\/td\u003e\n\u003ctd\u003e8.4\u003c\/td\u003e\n\u003ctd\u003e208-230\/440-480V 3Ph\u003c\/td\u003e\n\u003ctd\u003eAQQV\u003c\/td\u003e\n\u003ctd\u003e99327176\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"font-size:12.5px;color:#9B9EA3;margin-top:8px;line-height:1.55\"\u003eVoltage and phase are fixed per part number. Single-phase units are 115\/230 V and three-phase units are 208-230\/440-480 V; the two are not interchangeable. Confirm the supply before ordering.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eKey Features\u003c\/div\u003e\n\u003cdiv class=\"gs-lead\"\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e316 Stainless Steel\u003c\/strong\u003e — AISI 316 stainless throughout the liquid path.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHorizontal close-coupled build\u003c\/strong\u003e — motor and pump end on one shaft, on feet, so no coupling alignment and no separate baseplate to grout.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMultistage hydraulics\u003c\/strong\u003e — head is set by stage count at a fixed frame flow, so the duty point is chosen without oversizing the motor.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCartridge-format shaft seal\u003c\/strong\u003e — AQQE or AQQV, replaced without setting the seal by hand.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWRAS, ACS, NSF61, UBA approvals\u003c\/strong\u003e for drinking water contact.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e232 psi maximum operating pressure\u003c\/strong\u003e on this material build.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e1-1\/2 in NPT female suction and discharge\u003c\/strong\u003e — threaded, so no companion flanges to order.\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eShaft Seal Options\u003c\/div\u003e\n\u003cdiv class=\"gs-lead\"\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eAQQE — EPDM\u003c\/strong\u003e. Carbon against silicon carbide with an EPDM O-ring. The standard water seal: potable water, hot water and glycol. Mineral oils need AQQV.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAQQV — FKM\u003c\/strong\u003e. Carbon against silicon carbide with an FKM O-ring, for mineral oils, fuels and liquids that attack EPDM. Note that FKM carries the lower temperature ceiling of the two.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"gs-h\" style=\"font-size:13px;margin-top:12px\"\u003eLiquid temperature by seal\u003c\/div\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eAQQE\u003c\/strong\u003e — −4 °F to 248 °F on CM 10-1, CM 10-2, CM 10-3, CM 10-4.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAQQE\u003c\/strong\u003e — −4 °F to 194 °F on CM 10-5.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAQQV\u003c\/strong\u003e — −4 °F to 194 °F.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"font-size:12.5px;color:#9B9EA3;line-height:1.55\"\u003eIn the Grundfos type key the final letter is the rubber: E = EPDM, V = FKM. The seal is a specification decision, not a preference — it changes the published temperature limit.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eSpecifications\u003c\/div\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated flow at 60 Hz\u003c\/td\u003e\n\u003ctd\u003e52.8 GPM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated head range\u003c\/td\u003e\n\u003ctd\u003e53 to 306 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor power range\u003c\/td\u003e\n\u003ctd\u003e1.5 to 8.4 HP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor standard\u003c\/td\u003e\n\u003ctd\u003eNEMA, close-coupled\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure class\u003c\/td\u003e\n\u003ctd\u003eIP55\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency\u003c\/td\u003e\n\u003ctd\u003e60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSuction port\u003c\/td\u003e\n\u003ctd\u003e1-1\/2 in NPT female\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDischarge port\u003c\/td\u003e\n\u003ctd\u003e1-1\/2 in NPT female\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum operating pressure\u003c\/td\u003e\n\u003ctd\u003e232 psi\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient temperature range\u003c\/td\u003e\n\u003ctd\u003e−4 °F to 131 °F (-20 to 55 °C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePumped liquid\u003c\/td\u003e\n\u003ctd\u003eClean, thin, non-explosive liquids without solid particles or fibres\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePump orientation\u003c\/td\u003e\n\u003ctd\u003eHorizontal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrinking water approval\u003c\/td\u003e\n\u003ctd\u003eWRAS, ACS, NSF61, UBA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurve tolerance\u003c\/td\u003e\n\u003ctd\u003eISO9906:2012 3B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum efficiency index, MEI\u003c\/td\u003e\n\u003ctd\u003e≥ 0.52\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eMaterials\u003c\/div\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eComponent\u003c\/th\u003e\n\u003cth\u003eMaterial\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePump housing\u003c\/td\u003e\n\u003ctd\u003eStainless steel, EN 1.4401 (AISI 316)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eImpellers\u003c\/td\u003e\n\u003ctd\u003eStainless steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShaft seal faces\u003c\/td\u003e\n\u003ctd\u003eCarbon \/ silicon carbide\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeal and gasket rubber\u003c\/td\u003e\n\u003ctd\u003eEPDM (AQQE) or FKM (AQQV)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eApplications\u003c\/div\u003e\n\u003cdiv class=\"gs-lead\"\u003e\u003cul\u003e\n\u003cli\u003eSoftened, brackish and chloride-bearing water, where 304 would be at risk of pitting\u003c\/li\u003e\n\u003cli\u003eCoastal and marine-adjacent installations\u003c\/li\u003e\n\u003cli\u003eReverse osmosis feed and permeate, demineralised and deionised water\u003c\/li\u003e\n\u003cli\u003eChemical dosing and aggressive process liquids\u003c\/li\u003e\n\u003cli\u003eFood, beverage and pharmaceutical process duty\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eWhat Is Supplied\u003c\/div\u003e\n\u003cdiv class=\"gs-lead\"\u003e\n\u003cp\u003eEach part number is a complete pump: pump end, close-coupled motor and shaft seal, factory assembled and tested. The suction and discharge connections are NPT female threads, so no companion flanges or couplings are needed.\u003c\/p\u003e\n\u003cp\u003eMotor starters, variable frequency drives, pressure sensors, pressure tanks, base plates, foundation bolts and isolation valves are not included. These are fixed-speed pumps; for integrated variable-speed control see the CME range.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eOrdering Information\u003c\/div\u003e\n\u003cdiv class=\"gs-lead\"\u003e\n\u003cp\u003eSelect the HP and voltage, then the model, then the seal. Each combination is a distinct Grundfos part number, listed in the table above and shown in the SKU of the selected variant.\u003c\/p\u003e\n\u003cp\u003eThe picker shows only the combinations Grundfos publishes.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"gs-note\"\u003e\n\u003cb\u003eBefore You Order\u003c\/b\u003eConfirm the duty point against the rated head table, and confirm horsepower, voltage and phase against your service — single-phase and three-phase units are not interchangeable. Check that liquid temperature sits inside the limit for the seal selected, and that system pressure sits under the 232 psi rating of this material build.\u003c\/div\u003e\n\u003cdiv class=\"gs-contact\"\u003eFor engineering-led sizing and selection support or a factory submittal, email \u003ca href=\"mailto:sales@watermainsupply.com\"\u003esales@watermainsupply.com\u003c\/a\u003e or call \u003ca href=\"tel:18885104036\"\u003e1-888.510.4036\u003c\/a\u003e.\u003cbr\u003e© Watermain Supply — A division of E4 Industrial LLC\u003c\/div\u003e\n\u003c\/div\u003e\u003ch5\u003eData Sheet\u003c\/h5\u003e\u003cdiv class=\"gs\"\u003e\n\u003cdiv class=\"gs-dl\"\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0264\/1913\/4527\/files\/Grundfos_CM_A_I_G_Data_Booklet.pdf?v=1789539668\" target=\"_blank\" rel=\"noopener\"\u003eCM-A, CM-I, CM-G Data Booklet (60 Hz, US)\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0264\/1913\/4527\/files\/Grundfos_CM_Installation_and_Operating_Instructions.pdf?v=1789539668\" target=\"_blank\" rel=\"noopener\"\u003eCM Installation and Operating Instructions\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0264\/1913\/4527\/files\/Grundfos_CM_CME_Data_Booklet.pdf?v=1789539677\" target=\"_blank\" rel=\"noopener\"\u003eCM, CME Data Booklet\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0264\/1913\/4527\/files\/Grundfos_CM_Quick_Guide.pdf?v=1789539671\" target=\"_blank\" rel=\"noopener\"\u003eCM Quick Guide\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0264\/1913\/4527\/files\/Grundfos_CM_CME_Service_Kit_Catalogue.pdf?v=1789539670\" target=\"_blank\" rel=\"noopener\"\u003eCM, CME and Boosters Service Kit Catalogue\u003c\/a\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"gs-sec\" style=\"margin-top:10px\"\u003e\u003cp style=\"font-size:13px;color:#9B9EA3\"\u003eDimensional drawings and a factory submittal are available on request — email sales@watermainsupply.com with the part number.\u003c\/p\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003ch5\u003eVideos\u003c\/h5\u003e\u003cdiv class=\"gs\"\u003e\u003cdiv class=\"gs-sec\" style=\"margin-top:6px\"\u003e\u003cp style=\"font-size:13px;color:#9B9EA3\"\u003eProduct videos are being added to this listing. For a walkthrough in the meantime, email sales@watermainsupply.com.\u003c\/p\u003e\u003c\/div\u003e\u003c\/div\u003e\u003c!-- \/TABS --\u003e","brand":"Grundfos","offers":[{"title":"1.5 HP - 115\/230V 1Ph \/ CM 10-1 \/ AQQE","offer_id":47519233048751,"sku":"96943188","price":2205.36,"currency_code":"USD","in_stock":true},{"title":"1.5 HP - 115\/230V 1Ph \/ CM 10-1 \/ AQQV","offer_id":47519233081519,"sku":"96943191","price":2298.96,"currency_code":"USD","in_stock":true},{"title":"1.5 HP - 208-230\/440-480V 3Ph \/ CM 10-1 \/ AQQE","offer_id":47519233114287,"sku":"99155409","price":2124.72,"currency_code":"USD","in_stock":true},{"title":"1.5 HP - 208-230\/440-480V 3Ph \/ CM 10-1 \/ AQQV","offer_id":47519233147055,"sku":"99155419","price":2218.33,"currency_code":"USD","in_stock":true},{"title":"3.4 HP - 208-230\/440-480V 3Ph \/ CM 10-2 \/ AQQE","offer_id":47519233179823,"sku":"96943243","price":2438.64,"currency_code":"USD","in_stock":true},{"title":"3.4 HP - 208-230\/440-480V 3Ph \/ CM 10-2 \/ AQQV","offer_id":47519233212591,"sku":"96806991","price":2532.25,"currency_code":"USD","in_stock":true},{"title":"5.4 HP - 208-230\/440-480V 3Ph \/ CM 10-3 \/ AQQE","offer_id":47519233245359,"sku":"97568507","price":3121.92,"currency_code":"USD","in_stock":true},{"title":"5.4 HP - 208-230\/440-480V 3Ph \/ CM 10-3 \/ AQQV","offer_id":47519233278127,"sku":"96806993","price":3212.64,"currency_code":"USD","in_stock":true},{"title":"8.4 HP - 208-230\/440-480V 3Ph \/ CM 10-4 \/ AQQE","offer_id":47519233310895,"sku":"99311046","price":3740.4,"currency_code":"USD","in_stock":true},{"title":"8.4 HP - 208-230\/440-480V 3Ph \/ CM 10-4 \/ AQQV","offer_id":47519233343663,"sku":"99311107","price":3836.88,"currency_code":"USD","in_stock":true},{"title":"8.4 HP - 208-230\/440-480V 3Ph \/ CM 10-5 \/ AQQE","offer_id":47519233376431,"sku":"99327174","price":3971.52,"currency_code":"USD","in_stock":true},{"title":"8.4 HP - 208-230\/440-480V 3Ph \/ CM 10-5 \/ AQQV","offer_id":47519233409199,"sku":"99327176","price":4063.68,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0264\/1913\/4527\/files\/Grundfos_CM_Stainless_Horizontal_Multistage_Pump.webp?v=1789539732","url":"https:\/\/watermainsupply.com\/products\/grundfos-cm-10-g-horizontal-multistage-pump","provider":"Watermainsupply","version":"1.0","type":"link"}