{"product_id":"grundfos-10-sqe-submersible-well-pump","title":"Grundfos 10 SQE Submersible Well Pump","description":"\u003c!-- TABS --\u003e\u003ch5\u003eDescription\u003c\/h5\u003e\u003cdiv class=\"gs\"\u003e\n\u003cdiv class=\"gs-head\"\u003e\n\u003cdiv class=\"gs-eyebrow\"\u003eGRUNDFOS · 3-INCH SUBMERSIBLE WELL PUMP\u003c\/div\u003e\n\u003cdiv class=\"gs-title\"\u003e10 SQE\u003c\/div\u003e\n\u003cdiv class=\"gs-sub\"\u003eNominal 10 GPM constant-pressure submersible pump for 3 in and larger wells, in 7 hydraulic sizes from 110 to 370 ft nominal total dynamic head. Variable-speed Smart Motor, 3,000 to 10,700 rpm, with built-in soft start, dry-run, overload, over-temperature and voltage protection. Pair with a CU 302 for constant pressure.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"gs-badges\"\u003e\n\u003cdiv class=\"gs-badge\"\u003e3-15 GPM Flow Range\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003e110-370 ft Nominal TDH\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003eVariable Speed 3,000-10,700 rpm\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003e115V or 230V 1Ph\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003e3 in Minimum Well\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003e1-1\/4 in NPT Discharge\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eOverview\u003c\/div\u003e\n\u003cdiv class=\"gs-lead\"\u003e\n\u003cp\u003eSQE is a 3-inch diameter deep well submersible pump for 3 in and larger wells, suitable for both continuous and intermittent operation in domestic water supply, light commercial service, irrigation and tank applications. SQE pumps are equipped with a Grundfos Smart Motor: like SQ they use a high-efficiency permanent-magnet motor, but they add the ability to communicate. The Smart Motor talks to the CU 302 control box through the power leads, so no additional wires run down the well. That communication provides constant pressure control and the ability to change the pump performance while the pump is installed in the well. The SQE motor enables continuously variable speed control from 3,000 to 10,700 rpm, so the pump can be set to any duty point between those two curves. The variable speed control facility requires the CU 302 control unit.\u003c\/p\u003e\n\u003cp\u003eThe pumps are protected against dry running. A value of Pcut-out ensures cut-out of the pump in case of lack of water in the borehole, thus preventing a burnout of the motor. Pcut-out is factory-set. The integrated protection of all motors prevents damage in case the voltage moves outside the permissible range: the pump will cut out if the voltage falls below 150 V or rises above 315 V, and the motor is automatically cut in again when the voltage returns within range. Therefore no extra protection relay is needed. Exposure of the pump to heavy load causes the current consumption to rise; the motor automatically compensates by reducing the speed to 3000 rpm, and further overload will lead to stop. If the rotor is prevented from rotating, this is automatically detected and the power supply is cut out. Consequently, no extra motor protection is needed.\u003c\/p\u003e\n\u003cp\u003eThe pump design features floating impellers that are not fastened to the shaft. Each impeller has its own tungsten carbide \/ ceramic bearing, and the construction and materials ensure high wear resistance to sand for long product life. The hydraulic pump components are polyamide reinforced with 30 % glass fiber; the hydraulic design provides for high pump efficiency resulting in low energy consumption. Starting up a pump with very low counter pressure involves the risk of the entire impeller stack being lifted, also called upthrust, which may cause breakdown of both pump and motor. A top bearing protects both pump and motor against upthrust, thus preventing breakdown during the critical start-up phase.\u003c\/p\u003e\n\u003cp\u003eA built-in check valve with spring and low weight mean the pump may be installed vertically, horizontally or in any position in between, but it must not fall below the horizontal level in relation to the motor. For horizontal installation a flow sleeve is recommended, to ensure sufficient flow velocity past the motor for cooling and to prevent the motor and electronic unit from being buried in sand or mud.\u003c\/p\u003e\n\u003cp\u003eWith a CU 302 the system maintains a constant pressure within the maximum pump performance in spite of varying water consumption. The pressure is registered by the pressure sensor and transmitted to the CU 302, which adjusts the pump performance accordingly by changing the pump speed. When a tap is opened the pressure in the tank starts to drop; at a flow below roughly 1 gpm the pressure drops slowly and the pump starts when the tank is 7 psi below setpoint, running until it is 7 psi above setpoint — on\/off operation. At a flow above roughly 1 gpm the pressure drops quickly, the pump starts immediately and holds a constant pressure. With no consumption the pump boosts to 7 psi above setpoint and stops after a few seconds. Because the pump follows demand rather than cycling between two switch settings, the installation uses a 2 gal diaphragm tank instead of a conventional pressure tank.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background:#E1E3E6;border-left:3px solid #B8BDC4;padding:8px 14px;font-size:11.5px;color:#4A4A4F;margin-top:14px;line-height:1.5\"\u003eGenuine Grundfos equipment, factory-new in original packaging — sold and supported by Watermain Supply, an independent industrial distributor.\u003c\/div\u003e\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003ePerformance — Will It Do What You Need?\u003c\/div\u003e\n\u003cp style=\"font-size:13.5px;margin-bottom:10px\"\u003eSQE is variable speed, so each model covers a \u003cstrong\u003eband\u003c\/strong\u003e rather than one curve. Work out the head you need — depth to pumping water level, plus the pressure you want converted to feet, plus above-grade lift and friction loss — then pick the first model whose max-speed figure clears it. The head you need must fall between the two columns.\u003c\/p\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003cth\u003eHP\u003c\/th\u003e\n\u003cth\u003eShut-off head at 3,000 rpm — min speed\u003c\/th\u003e\n\u003cth\u003eHead at rated flow at 10,700 rpm — max speed\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e10 SQE05-110\u003c\/td\u003e\n\u003ctd\u003e1\/2\u003c\/td\u003e\n\u003ctd\u003e12 ft\u003c\/td\u003e\n\u003ctd\u003e105 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e10 SQE05-160\u003c\/td\u003e\n\u003ctd\u003e1\/2\u003c\/td\u003e\n\u003ctd\u003e17 ft\u003c\/td\u003e\n\u003ctd\u003e164 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e10 SQE07-200\u003c\/td\u003e\n\u003ctd\u003e3\/4\u003c\/td\u003e\n\u003ctd\u003e23 ft\u003c\/td\u003e\n\u003ctd\u003e215 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e10 SQE07-240\u003c\/td\u003e\n\u003ctd\u003e3\/4\u003c\/td\u003e\n\u003ctd\u003e29 ft\u003c\/td\u003e\n\u003ctd\u003e267 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e10 SQE10-290\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003ctd\u003e34 ft\u003c\/td\u003e\n\u003ctd\u003e328 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e10 SQE15-330\u003c\/td\u003e\n\u003ctd\u003e1-1\/2\u003c\/td\u003e\n\u003ctd\u003e40 ft\u003c\/td\u003e\n\u003ctd\u003e390 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e10 SQE15-370\u003c\/td\u003e\n\u003ctd\u003e1-1\/2\u003c\/td\u003e\n\u003ctd\u003e46 ft\u003c\/td\u003e\n\u003ctd\u003e434 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"font-size:12.5px;color:#9B9EA3;margin-top:8px;line-height:1.55\"\u003eFigures are the Grundfos system sizing matrix for the SQE range. Multiply required PSI by 2.31 to convert to feet of head. Every calculated head requirement must lie between the selected model’s minimum and maximum speed curves; double-check the duty point against the published curve before specifying. Constant-pressure operation and any speed below 10,700 rpm require the CU 302 control unit.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eModels, Voltage \u0026amp; Phase\u003c\/div\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003cth\u003eHP\u003c\/th\u003e\n\u003cth\u003eVoltage \u0026amp; Phase\u003c\/th\u003e\n\u003cth\u003eDischarge\u003c\/th\u003e\n\u003cth\u003ePart No.\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e10 SQE05-110\u003c\/td\u003e\n\u003ctd\u003e1\/2\u003c\/td\u003e\n\u003ctd\u003e115V 1Ph\u003c\/td\u003e\n\u003ctd\u003e1-1\/4 in NPT\u003c\/td\u003e\n\u003ctd\u003e96160209\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e10 SQE05-160\u003c\/td\u003e\n\u003ctd\u003e1\/2\u003c\/td\u003e\n\u003ctd\u003e115V 1Ph\u003c\/td\u003e\n\u003ctd\u003e1-1\/4 in NPT\u003c\/td\u003e\n\u003ctd\u003e96160210\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e10 SQE05-110\u003c\/td\u003e\n\u003ctd\u003e1\/2\u003c\/td\u003e\n\u003ctd\u003e230V 1Ph\u003c\/td\u003e\n\u003ctd\u003e1-1\/4 in NPT\u003c\/td\u003e\n\u003ctd\u003e96160182\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e10 SQE05-160\u003c\/td\u003e\n\u003ctd\u003e1\/2\u003c\/td\u003e\n\u003ctd\u003e230V 1Ph\u003c\/td\u003e\n\u003ctd\u003e1-1\/4 in NPT\u003c\/td\u003e\n\u003ctd\u003e96160183\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e10 SQE07-200\u003c\/td\u003e\n\u003ctd\u003e3\/4\u003c\/td\u003e\n\u003ctd\u003e230V 1Ph\u003c\/td\u003e\n\u003ctd\u003e1-1\/4 in NPT\u003c\/td\u003e\n\u003ctd\u003e96160184\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e10 SQE07-240\u003c\/td\u003e\n\u003ctd\u003e3\/4\u003c\/td\u003e\n\u003ctd\u003e230V 1Ph\u003c\/td\u003e\n\u003ctd\u003e1-1\/4 in NPT\u003c\/td\u003e\n\u003ctd\u003e96160185\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e10 SQE10-290\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003ctd\u003e230V 1Ph\u003c\/td\u003e\n\u003ctd\u003e1-1\/4 in NPT\u003c\/td\u003e\n\u003ctd\u003e96160186\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e10 SQE15-330\u003c\/td\u003e\n\u003ctd\u003e1-1\/2\u003c\/td\u003e\n\u003ctd\u003e230V 1Ph\u003c\/td\u003e\n\u003ctd\u003e1-1\/4 in NPT\u003c\/td\u003e\n\u003ctd\u003e96160187\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e10 SQE15-370\u003c\/td\u003e\n\u003ctd\u003e1-1\/2\u003c\/td\u003e\n\u003ctd\u003e230V 1Ph\u003c\/td\u003e\n\u003ctd\u003e1-1\/4 in NPT\u003c\/td\u003e\n\u003ctd\u003e93001328\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"font-size:12.5px;color:#9B9EA3;margin-top:8px;line-height:1.55\"\u003eAll 10 SQE models are single phase. The 1\/2 HP models are built in two separate motor versions, 1 x 100-115 V and 1 x 200-240 V, ordered as different part numbers — they are not field-convertible and there is no terminal board to change. The 3\/4, 1 and 1-1\/2 HP models are 200-240 V only.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eKey Features\u003c\/div\u003e\n\u003cdiv class=\"gs-lead\"\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eConstant pressure control\u003c\/strong\u003e — with a CU 302 the pump holds your chosen setpoint from a trickle to full flow, so pressure does not sag when a second fixture opens.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContinuously variable speed, 3,000 to 10,700 rpm\u003c\/strong\u003e — the duty point can be moved anywhere between the two curves, and changed with the pump still down the well.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectronic control and communication\u003c\/strong\u003e — GENIbus to the CU 302 over the power cable, Bluetooth to Grundfos GO at the control unit, with alarm and warning indication including dry running, overvoltage, overtemperature and overload.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDry-run protection\u003c\/strong\u003e — factory-set Pcut-out stops the pump when the borehole runs short of water, preventing motor burnout.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOvervoltage and undervoltage protection\u003c\/strong\u003e — cuts out below 150 V and above 315 V and restarts automatically when supply returns to range. No protection relay needed.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOverload protection\u003c\/strong\u003e — the motor reduces speed to 3000 rpm under heavy load, stops on further overload, and cuts power if the rotor is blocked. No separate motor protection needed.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOvertemperature protection\u003c\/strong\u003e — a temperature sensor in the electronic unit cuts the motor out when temperature rises too high and cuts back in once it drops.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSoft start\u003c\/strong\u003e — reduces starting current and gives smooth, steady acceleration, minimising wear on the pump and avoiding overloading the mains at start-up.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh starting torque\u003c\/strong\u003e — high locked-rotor torque of the permanent magnet motor combined with few pump stages, and the starting reliability holds up at low supply voltage.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtection against upthrust\u003c\/strong\u003e — a top bearing protects pump and motor against impeller-stack lift during the critical start-up phase.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFloating impellers\u003c\/strong\u003e — not fastened to the shaft, each with its own tungsten carbide \/ ceramic bearing, for high wear resistance to sand.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e2-wire single-phase design\u003c\/strong\u003e — the CU 302 communicates over the same two power leads, so nothing extra runs down the well.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBuilt-in check valve with spring\u003c\/strong\u003e and a 2.68 in pump diameter, 2.91 in including the cable guard, for 3 in and larger wells.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStainless steel exterior\u003c\/strong\u003e — AISI 304 outlet chamber, pump sleeve, cable guard, shaft and motor housing.\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eSpecifications\u003c\/div\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eMains supply to pump\u003c\/td\u003e\n\u003ctd\u003e1 x 200-240 V -10 % \/ +6 %, 50\/60 Hz, PE or 1 x 100-115 V -10 % \/ +6 %, 50\/60 Hz, PE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhase\u003c\/td\u003e\n\u003ctd\u003eSingle phase, 2-wire\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower factor\u003c\/td\u003e\n\u003ctd\u003ePF = 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStarting\u003c\/td\u003e\n\u003ctd\u003eSoft starting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpeed range\u003c\/td\u003e\n\u003ctd\u003eContinuously variable, 3,000 to 10,700 rpm, via CU 302\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication\u003c\/td\u003e\n\u003ctd\u003eGrundfos Smart Motor, GENIbus over the power cable to CU 302; Bluetooth to Grundfos GO at the CU 302\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReset function\u003c\/td\u003e\n\u003ctd\u003eVia CU 302\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStopping\u003c\/td\u003e\n\u003ctd\u003eSoft stopping when stopped by CU 302\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRun-up time\u003c\/td\u003e\n\u003ctd\u003eMaximum 3 seconds. No limitation to the number of starts\/stops per hour\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStarting current\u003c\/td\u003e\n\u003ctd\u003eEqual to the highest value stated on the motor nameplate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor protection\u003c\/td\u003e\n\u003ctd\u003eBuilt-in: dry running, overvoltage and undervoltage (cuts out below 150 V and above 315 V), overload, overtemperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor\u003c\/td\u003e\n\u003ctd\u003eMSE 3 permanent-magnet submersible motor with integrated electronic unit and variable speed control, water-lubricated slide bearings, factory-filled with SML-3 motor liquid\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor cable\u003c\/td\u003e\n\u003ctd\u003e3 wire, 14 AWG XLPE, 5 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePipe connection\u003c\/td\u003e\n\u003ctd\u003e1-1\/4 in NPT (male thread must be NPT type)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBorehole diameter\u003c\/td\u003e\n\u003ctd\u003eMinimum 3 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstallation depth\u003c\/td\u003e\n\u003ctd\u003eMaximum 500 ft below the static water table. Minimum 1.65 ft below dynamic water level\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNPSH\u003c\/td\u003e\n\u003ctd\u003eMinimum 27 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStrainer\u003c\/td\u003e\n\u003ctd\u003eHoles in the suction strainer 0.075 in diameter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePumped liquids\u003c\/td\u003e\n\u003ctd\u003eSQE (AISI 304): pH 5 to 9. Clear, cold water free of air or gases\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLiquid temperature\u003c\/td\u003e\n\u003ctd\u003eMinimum 34 °F, maximum 86 °F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage temperature\u003c\/td\u003e\n\u003ctd\u003e-4 °F to +140 °F, frost-free or with frost-proof motor liquid\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePump diameter\u003c\/td\u003e\n\u003ctd\u003e2.68 in; 2.91 in including cable guard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperation via generator\u003c\/td\u003e\n\u003ctd\u003eGenerator output equal to motor input power P1 plus 50 %, and at least P1 plus 10 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEarth leakage circuit breaker\u003c\/td\u003e\n\u003ctd\u003eWhere an ELCB is used as additional protection it must trip when earth fault currents with pulsating DC content occur\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRadio noise\u003c\/td\u003e\n\u003ctd\u003eComplies with EMC Directive 2014\/30\/EU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eElectrical \u0026amp; Dimensional Data\u003c\/div\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003cth\u003eHP\u003c\/th\u003e\n\u003cth\u003eFull load A, 230V\u003c\/th\u003e\n\u003cth\u003eFull load A, 115V\u003c\/th\u003e\n\u003cth\u003eOverload A, 230V\u003c\/th\u003e\n\u003cth\u003eOverload A, 115V\u003c\/th\u003e\n\u003cth\u003eA — overall in\u003c\/th\u003e\n\u003cth\u003eB — motor in\u003c\/th\u003e\n\u003cth\u003eC — pump end in\u003c\/th\u003e\n\u003cth\u003eShip wt lb\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e10 SQE05-110\u003c\/td\u003e\n\u003ctd\u003e1\/2\u003c\/td\u003e\n\u003ctd\u003e2.9\u003c\/td\u003e\n\u003ctd\u003e6.1\u003c\/td\u003e\n\u003ctd\u003e5\u003c\/td\u003e\n\u003ctd\u003e11\u003c\/td\u003e\n\u003ctd\u003e29.1\u003c\/td\u003e\n\u003ctd\u003e19.0\u003c\/td\u003e\n\u003ctd\u003e10.1\u003c\/td\u003e\n\u003ctd\u003e11\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e10 SQE05-160\u003c\/td\u003e\n\u003ctd\u003e1\/2\u003c\/td\u003e\n\u003ctd\u003e4.1\u003c\/td\u003e\n\u003ctd\u003e8.6\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003ctd\u003e11\u003c\/td\u003e\n\u003ctd\u003e29.1\u003c\/td\u003e\n\u003ctd\u003e19.0\u003c\/td\u003e\n\u003ctd\u003e10.1\u003c\/td\u003e\n\u003ctd\u003e11\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e10 SQE07-200\u003c\/td\u003e\n\u003ctd\u003e3\/4\u003c\/td\u003e\n\u003ctd\u003e5.3\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003ctd\u003e30.2\u003c\/td\u003e\n\u003ctd\u003e19.0\u003c\/td\u003e\n\u003ctd\u003e11.2\u003c\/td\u003e\n\u003ctd\u003e13\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e10 SQE07-240\u003c\/td\u003e\n\u003ctd\u003e3\/4\u003c\/td\u003e\n\u003ctd\u003e6.0\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003ctd\u003e32.4\u003c\/td\u003e\n\u003ctd\u003e19.0\u003c\/td\u003e\n\u003ctd\u003e13.3\u003c\/td\u003e\n\u003ctd\u003e13\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e10 SQE10-290\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003ctd\u003e7.7\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003ctd\u003e11\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003ctd\u003e33.8\u003c\/td\u003e\n\u003ctd\u003e20.4\u003c\/td\u003e\n\u003ctd\u003e13.3\u003c\/td\u003e\n\u003ctd\u003e14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e10 SQE15-330\u003c\/td\u003e\n\u003ctd\u003e1-1\/2\u003c\/td\u003e\n\u003ctd\u003e8.9\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003ctd\u003e34.8\u003c\/td\u003e\n\u003ctd\u003e20.4\u003c\/td\u003e\n\u003ctd\u003e14.4\u003c\/td\u003e\n\u003ctd\u003e15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e10 SQE15-370\u003c\/td\u003e\n\u003ctd\u003e1-1\/2\u003c\/td\u003e\n\u003ctd\u003e10.1\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003ctd\u003e37.0\u003c\/td\u003e\n\u003ctd\u003e20.4\u003c\/td\u003e\n\u003ctd\u003e16.5\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"font-size:12.5px;color:#9B9EA3;margin-top:8px;line-height:1.55\"\u003eGrundfos publishes one motor-data table for the SQ\/SQE range in the current data booklet and prints it under the SQE type designations; the figures above are those values. Confirm against the motor nameplate before sizing conductors or overcurrent protection, and select drop cable from the cable-sizing table under Ordering Information. Dimensions D and E — pump diameter and diameter including cable guard — are 2.6 in and 2.9 in on every model.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eMaterials\u003c\/div\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eComponent\u003c\/th\u003e\n\u003cth\u003eMaterial\u003c\/th\u003e\n\u003cth\u003eEN\u003c\/th\u003e\n\u003cth\u003eAISI\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutlet chamber\u003c\/td\u003e\n\u003ctd\u003eStainless steel\u003c\/td\u003e\n\u003ctd\u003e1.4301\u003c\/td\u003e\n\u003ctd\u003e304\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePump sleeve\u003c\/td\u003e\n\u003ctd\u003eStainless steel\u003c\/td\u003e\n\u003ctd\u003e1.4301\u003c\/td\u003e\n\u003ctd\u003e304\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShaft with coupling\u003c\/td\u003e\n\u003ctd\u003eStainless steel \/ sintered steel\u003c\/td\u003e\n\u003ctd\u003e1.4301\u003c\/td\u003e\n\u003ctd\u003e304\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable guard\u003c\/td\u003e\n\u003ctd\u003eStainless steel\u003c\/td\u003e\n\u003ctd\u003e1.4301\u003c\/td\u003e\n\u003ctd\u003e304\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eScrews for cable guard\u003c\/td\u003e\n\u003ctd\u003eStainless steel\u003c\/td\u003e\n\u003ctd\u003e1.4401\u003c\/td\u003e\n\u003ctd\u003e316\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eImpeller with tungsten carbide bearing\u003c\/td\u003e\n\u003ctd\u003ePolyamide\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGuide vanes, chambers, valve casing\u003c\/td\u003e\n\u003ctd\u003ePolyamide\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eValve seat, top bearing, O-ring, lip seal ring\u003c\/td\u003e\n\u003ctd\u003eNBR rubber\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNeck ring\u003c\/td\u003e\n\u003ctd\u003eTPU \/ PBT\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLock ring\u003c\/td\u003e\n\u003ctd\u003eStainless spring steel\u003c\/td\u003e\n\u003ctd\u003e1.4310\u003c\/td\u003e\n\u003ctd\u003e310\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpring\u003c\/td\u003e\n\u003ctd\u003eStainless spring steel\u003c\/td\u003e\n\u003ctd\u003e1.4406\u003c\/td\u003e\n\u003ctd\u003e316LN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor stator, rotor, top cover\u003c\/td\u003e\n\u003ctd\u003eStainless steel\u003c\/td\u003e\n\u003ctd\u003e1.4301\u003c\/td\u003e\n\u003ctd\u003e304\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor thrust bearing\u003c\/td\u003e\n\u003ctd\u003eCarbon\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor radial bearings, upper and lower\u003c\/td\u003e\n\u003ctd\u003eSilicon carbide \/ tungsten carbide coating\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor liquid\u003c\/td\u003e\n\u003ctd\u003eSML-3\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eApplications\u003c\/div\u003e\n\u003cdiv class=\"gs-lead\"\u003e\n\u003cul\u003e\n\u003cli\u003eDomestic water supply in single-family dwellings and seasonal homes not connected to municipal waterworks\u003c\/li\u003e\n\u003cli\u003eLight commercial water supply and small waterworks\u003c\/li\u003e\n\u003cli\u003eIrrigation systems\u003c\/li\u003e\n\u003cli\u003eTank applications — liquid transfer, emptying or filling a tank, pumping from one tank to another\u003c\/li\u003e\n\u003cli\u003ePressure boosting and groundwater lowering\u003c\/li\u003e\n\u003cli\u003eMaintaining a constant water table\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eSQE is normally installed with a CU 302 control unit, a pressure sensor and a 2 gal diaphragm tank for constant-pressure service. Without a CU 302 an SQE runs at maximum speed like an SQ on a conventional pressure switch and pressure tank, but the constant-pressure function and the variable-speed range are not available.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eOrdering Information\u003c\/div\u003e\n\u003cdiv class=\"gs-lead\"\u003e\n\u003cp\u003e\u003cstrong\u003eType key.\u003c\/strong\u003e In \u003cem\u003e10 SQE05-110\u003c\/em\u003e: \u003cem\u003e10\u003c\/em\u003e is rated gallons per minute, \u003cem\u003eSQE\u003c\/em\u003e is the type range (E for electronic communication), \u003cem\u003e05\u003c\/em\u003e is horsepower and \u003cem\u003e-110\u003c\/em\u003e is total dynamic head in feet at rated flow.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOrder by part number.\u003c\/strong\u003e 10 SQE05-110 — 96160182; 10 SQE05-160 — 96160183; 10 SQE07-200 — 96160184; 10 SQE07-240 — 96160185; 10 SQE10-290 — 96160186; 10 SQE15-330 — 96160187; 10 SQE15-370 — 93001328. The 1\/2 HP models carry a second part number for the 100-115 V version: 10 SQE05-110 — 96160209; 10 SQE05-160 — 96160210.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable sizing.\u003c\/strong\u003e Maximum drop cable length in feet by copper wire size:\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eVolts\u003c\/th\u003e\n\u003cth\u003eHP\u003c\/th\u003e\n\u003cth\u003eAmps\u003c\/th\u003e\n\u003cth\u003e14 AWG\u003c\/th\u003e\n\u003cth\u003e12 AWG\u003c\/th\u003e\n\u003cth\u003e10 AWG\u003c\/th\u003e\n\u003cth\u003e8 AWG\u003c\/th\u003e\n\u003cth\u003e6 AWG\u003c\/th\u003e\n\u003cth\u003e4 AWG\u003c\/th\u003e\n\u003cth\u003e2 AWG\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e115\u003c\/td\u003e\n\u003ctd\u003e1\/2\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003ctd\u003e140\u003c\/td\u003e\n\u003ctd\u003e220\u003c\/td\u003e\n\u003ctd\u003e360\u003c\/td\u003e\n\u003ctd\u003e550\u003c\/td\u003e\n\u003ctd\u003e880\u003c\/td\u003e\n\u003ctd\u003e1390\u003c\/td\u003e\n\u003ctd\u003e2260\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e230\u003c\/td\u003e\n\u003ctd\u003e1\/2\u003c\/td\u003e\n\u003ctd\u003e5.2\u003c\/td\u003e\n\u003ctd\u003e640\u003c\/td\u003e\n\u003ctd\u003e1000\u003c\/td\u003e\n\u003ctd\u003e1660\u003c\/td\u003e\n\u003ctd\u003e2250\u003c\/td\u003e\n\u003ctd\u003e4060\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e230\u003c\/td\u003e\n\u003ctd\u003e3\/4\u003c\/td\u003e\n\u003ctd\u003e8.4\u003c\/td\u003e\n\u003ctd\u003e400\u003c\/td\u003e\n\u003ctd\u003e620\u003c\/td\u003e\n\u003ctd\u003e1030\u003c\/td\u003e\n\u003ctd\u003e1580\u003c\/td\u003e\n\u003ctd\u003e2510\u003c\/td\u003e\n\u003ctd\u003e3970\u003c\/td\u003e\n\u003ctd\u003e–\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e230\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003ctd\u003e11.2\u003c\/td\u003e\n\u003ctd\u003e300\u003c\/td\u003e\n\u003ctd\u003e460\u003c\/td\u003e\n\u003ctd\u003e770\u003c\/td\u003e\n\u003ctd\u003e1190\u003c\/td\u003e\n\u003ctd\u003e1890\u003c\/td\u003e\n\u003ctd\u003e2980\u003c\/td\u003e\n\u003ctd\u003e4850\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e230\u003c\/td\u003e\n\u003ctd\u003e1-1\/2\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003ctd\u003e280\u003c\/td\u003e\n\u003ctd\u003e430\u003c\/td\u003e\n\u003ctd\u003e720\u003c\/td\u003e\n\u003ctd\u003e1110\u003c\/td\u003e\n\u003ctd\u003e1760\u003c\/td\u003e\n\u003ctd\u003e2780\u003c\/td\u003e\n\u003ctd\u003e4530\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cdiv class=\"gs-lead\"\u003e\u003cp\u003e\u003cstrong\u003eAccessories.\u003c\/strong\u003e CU 302 control unit with PSI sensor (UL) — product number 92817764; CU 302 without sensor, PSI (UL) — 92799799. SQ, SQE flow sleeve, complete — 98148594. SP, SQ, SQE wrench — 99588350. Cable kit, SQ SQE 14 AWG 5 ft NSF, motor model C — 97778332.\u003c\/p\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"gs-note\"\u003e\n\u003cb\u003eBefore You Order\u003c\/b\u003eConstant pressure needs a CU 302. The pump does not include one; its brochure, wiring diagram and operating instructions are on the CU 302 listing. Without a CU 302 you get a fixed-speed pump on a pressure switch — which is what an SQ is, for less money. Order the CU 302 and pressure sensor with the pump, or buy SQ instead. Confirm the voltage. The 1\/2 HP models are ordered as either a 115 V or a 230 V machine and cannot be changed in the field; 3\/4 HP and larger are 230 V only. Confirm the depth to pumping water level at your maximum draw, not the total well depth — pump selection and setting depth are made from the drawdown level. The motor must sit at least 3 ft below maximum drawdown, never lower than the top of the well screen, and never within 5 ft of the well bottom. In a new well, the well should be fully developed and bailed or blown free of cuttings and sand before the pump goes in; if this pump replaces an oil-filled submersible or an oil-lubricated line-shaft turbine, the well must be blown or bailed clear of oil first. This pump has not been investigated for use in swimming pool or marine areas. The pump must never be connected to a capacitor, to any control box other than a Grundfos CU unit, or to an external frequency converter.\u003c\/div\u003e\n\u003cdiv class=\"gs-contact\"\u003eFor engineering-led sizing and selection support or a factory submittal, email \u003ca href=\"mailto:sales@watermainsupply.com\"\u003esales@watermainsupply.com\u003c\/a\u003e or call \u003ca href=\"tel:18885104036\"\u003e1-888.510.4036\u003c\/a\u003e.\u003cbr\u003e© Watermain Supply — A division of E4 Industrial LLC\u003c\/div\u003e\n\u003c\/div\u003e\u003ch5\u003eData Sheet\u003c\/h5\u003e\u003cdiv class=\"gs\"\u003e\u003cdiv class=\"gs-dl\"\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0264\/1913\/4527\/files\/SQ_SQE_us.pdf?v=1788826864\" target=\"_blank\" rel=\"noopener\"\u003eSQ, SQE Installation and Operating Instructions\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0264\/1913\/4527\/files\/SQE_Brochure_2.pdf?v=1788826864\" target=\"_blank\" rel=\"noopener\"\u003eGrundfos SQE Constant Pressure Groundwater System Brochure\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0264\/1913\/4527\/files\/SQ_SQE_Brochure.pdf?v=1788826865\" target=\"_blank\" rel=\"noopener\"\u003eGrundfos SQ\/SQE Range Brochure\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0264\/1913\/4527\/files\/SQ_Performance_Curves.pdf?v=1788826864\" target=\"_blank\" rel=\"noopener\"\u003e3 in SQ Sizing Guide — Curves and Sizing Charts\u003c\/a\u003e\n\u003c\/div\u003e\u003c\/div\u003e\u003ch5\u003eVideos\u003c\/h5\u003e\u003cdiv class=\"gs\"\u003e\u003cdiv class=\"gs-sec\" style=\"margin-top:6px\"\u003e\n\u003cdiv style=\"display:grid;grid-template-columns:repeat(auto-fit,minmax(300px,1fr));gap:20px\"\u003e\n\u003cdiv\u003e\n\u003cdiv style=\"position:relative;width:100%;padding-top:56.25%;background:#4A4A4F\"\u003e\u003ciframe src=\"https:\/\/www.youtube.com\/embed\/_Kn3OVDRZOE?si=3DToNwIsKFSrV9Bt\" title=\"SQ and SQE: Constant Pressure Pump Overview\" loading=\"lazy\" frameborder=\"0\" style=\"position:absolute;top:0;left:0;width:100%;height:100%;border:0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share\" referrerpolicy=\"strict-origin-when-cross-origin\" allowfullscreen\u003e\u003c\/iframe\u003e\u003c\/div\u003e\n\u003cp style=\"font-family:Arial,Helvetica,sans-serif;font-size:13px;line-height:1.45;color:#4A4A4F;margin:8px 0 0\"\u003eSQ and SQE: Constant Pressure Pump Overview \u003cspan style=\"color:#9B9EA3\"\u003e(4:02)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cdiv style=\"position:relative;width:100%;padding-top:56.25%;background:#4A4A4F\"\u003e\u003ciframe src=\"https:\/\/www.youtube.com\/embed\/lHPdSndKQqs?si=tktPTsRHA2Z-H07V\" title=\"Installing a Grundfos SQE Constant Pressure System\" loading=\"lazy\" frameborder=\"0\" style=\"position:absolute;top:0;left:0;width:100%;height:100%;border:0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share\" referrerpolicy=\"strict-origin-when-cross-origin\" allowfullscreen\u003e\u003c\/iframe\u003e\u003c\/div\u003e\n\u003cp style=\"font-family:Arial,Helvetica,sans-serif;font-size:13px;line-height:1.45;color:#4A4A4F;margin:8px 0 0\"\u003eInstalling a Grundfos SQE Constant Pressure System \u003cspan style=\"color:#9B9EA3\"\u003e(5:22)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cdiv style=\"position:relative;width:100%;padding-top:56.25%;background:#4A4A4F\"\u003e\u003ciframe src=\"https:\/\/www.youtube.com\/embed\/U4gomM0GLr0?si=CP3NowIBbbzTzjEP\" title=\"Grundfos SQE Pump Restores Clean Water to a California Family\" loading=\"lazy\" frameborder=\"0\" style=\"position:absolute;top:0;left:0;width:100%;height:100%;border:0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share\" referrerpolicy=\"strict-origin-when-cross-origin\" allowfullscreen\u003e\u003c\/iframe\u003e\u003c\/div\u003e\n\u003cp style=\"font-family:Arial,Helvetica,sans-serif;font-size:13px;line-height:1.45;color:#4A4A4F;margin:8px 0 0\"\u003eGrundfos SQE Pump Restores Clean Water to a California Family \u003cspan style=\"color:#9B9EA3\"\u003e(6:42)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp style=\"font-family:Arial,Helvetica,sans-serif;font-size:12px;color:#9B9EA3;margin:16px 0 0\"\u003eVideos produced by Grundfos and hosted on YouTube.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/div\u003e\u003ch5\u003eGrundfos HOME App\u003c\/h5\u003e\u003cdiv class=\"gs\"\u003e\u003cdiv class=\"gs-sec\" style=\"margin-top:6px\"\u003e\n\u003cdiv class=\"gs-h\"\u003eSet Up \u0026amp; Monitor From Your Phone\u003c\/div\u003e\n\u003cdiv class=\"gs-lead\"\u003e\u003cp\u003eThe free Grundfos HOME app gives you full control of your water system from an iOS or Android phone. Pair an SQE with a CU 302 control unit and the app reports pump information around the clock, sends alert notifications on important events so you can act before the water goes off, and carries a built-in watering calendar with an internal clock so irrigation routines run to schedule without a timer. Installer details are stored in the app, so whoever set the system up is one tap away.\u003c\/p\u003e\u003c\/div\u003e\n\u003cdiv style=\"margin-top:16px\"\u003e\n\u003ca href=\"https:\/\/apps.apple.com\/us\/app\/grundfos-home\/id1592451846\" target=\"_blank\" rel=\"noopener\" style=\"display:inline-block;background:#B3122A;color:#fff!important;font-family:Arial Black,Arial,sans-serif;font-size:13px;letter-spacing:1px;text-transform:uppercase;text-decoration:none;padding:12px 24px;border-radius:999px;margin:0 10px 10px 0\"\u003eDownload for iOS\u003c\/a\u003e\u003ca href=\"https:\/\/play.google.com\/store\/apps\/details?id=com.grundfos.home\u0026amp;pcampaignid=web_share\" target=\"_blank\" rel=\"noopener\" style=\"display:inline-block;background:#4A4A4F;color:#fff!important;font-family:Arial Black,Arial,sans-serif;font-size:13px;letter-spacing:1px;text-transform:uppercase;text-decoration:none;padding:12px 24px;border-radius:999px;margin:0 10px 10px 0\"\u003eDownload for Android\u003c\/a\u003e\n\u003c\/div\u003e\n\u003cp style=\"font-size:12px;color:#9B9EA3;margin-top:14px;line-height:1.6\"\u003eGrundfos HOME is a free app from Grundfos Holding A\/S. It connects through the CU 302 control unit, which is required and is sold separately, and Bluetooth must be enabled on the CU 302 operating panel before pairing. Installers and service technicians use a separate free Grundfos app, Grundfos GO, as the commissioning and diagnostic tool; ask us for the link if you need it.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/div\u003e\u003c!-- \/TABS --\u003e","brand":"Grundfos","offers":[{"title":"1\/2 HP - 115V 1Ph \/ 10 SQE05-110","offer_id":47457479557295,"sku":"96160209","price":1292.81,"currency_code":"USD","in_stock":true},{"title":"1\/2 HP - 115V 1Ph \/ 10 SQE05-160","offer_id":47457479590063,"sku":"96160210","price":1297.2,"currency_code":"USD","in_stock":true},{"title":"1\/2 HP - 230V 1Ph \/ 10 SQE05-110","offer_id":47457479622831,"sku":"96160182","price":1292.81,"currency_code":"USD","in_stock":true},{"title":"1\/2 HP - 230V 1Ph \/ 10 SQE05-160","offer_id":47457479655599,"sku":"96160183","price":1297.2,"currency_code":"USD","in_stock":true},{"title":"3\/4 HP - 230V 1Ph \/ 10 SQE07-200","offer_id":47457479688367,"sku":"96160184","price":1544.11,"currency_code":"USD","in_stock":true},{"title":"3\/4 HP - 230V 1Ph \/ 10 SQE07-240","offer_id":47457479721135,"sku":"96160185","price":1619.31,"currency_code":"USD","in_stock":true},{"title":"1 HP - 230V 1Ph \/ 10 SQE10-290","offer_id":47457479753903,"sku":"96160186","price":1774.09,"currency_code":"USD","in_stock":true},{"title":"1-1\/2 HP - 230V 1Ph \/ 10 SQE15-330","offer_id":47457479786671,"sku":"96160187","price":1813.57,"currency_code":"USD","in_stock":true},{"title":"1-1\/2 HP - 230V 1Ph \/ 10 SQE15-370","offer_id":47457479819439,"sku":"93001328","price":1883.13,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0264\/1913\/4527\/files\/Grundfos_SQE_Submersible_Pump.webp?v=1788826893","url":"https:\/\/watermainsupply.com\/products\/grundfos-10-sqe-submersible-well-pump","provider":"Watermainsupply","version":"1.0","type":"link"}