{"product_id":"franklin-electric-submonitor-three-phase-motor-protection","title":"Franklin Electric SubMonitor Three-Phase Motor Protection","description":"\u003c!-- TABS --\u003e\u003ch5\u003eDescription\u003c\/h5\u003e\u003cdiv class=\"gs\"\u003e\n\u003cdiv class=\"gs-head\"\u003e\n\u003cdiv class=\"gs-eyebrow\"\u003eFranklin Electric · Motor Protection\u003c\/div\u003e\n\u003cdiv class=\"gs-title\"\u003eSubMonitor Three-Phase Motor Protection\u003c\/div\u003e\n\u003cdiv class=\"gs-sub\"\u003e12 Franklin part numbers: SubMonitor Connect, options and SubMonitor parts.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"gs-badges\"\u003e\n\u003cdiv class=\"gs-badge\"\u003eThree-Phase, 200-600 VAC\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003e1-700 HP Motors\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003e0.1-135 A, to 1000 A with CTs\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003eClass 5-30 Electronic Overload\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003eDry-Run (Under Power) Protection\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003eModbus RTU and Bluetooth\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003eNEMA 4X Remote Display\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003eUL\/cUL, CSA\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background:#FFFFFF;border:1px solid #C7CBD1;border-top:3px solid #B3122A;padding:12px 16px 12px;margin:16px 0 4px;font-size:13.5px;line-height:1.55;color:#4A4A4F\"\u003e\n\u003cdiv style=\"font-family:Arial Black,Arial,sans-serif;font-size:11px;letter-spacing:1.2px;text-transform:uppercase;color:#B3122A;margin-bottom:8px\"\u003eWhat Ships and What It Needs to Run\u003c\/div\u003e\n\u003cp style=\"margin:0 0 6px\"\u003e\u003cstrong style=\"color:#B3122A\"\u003eIncluded:\u003c\/strong\u003e the SubMonitor Connect relay with its detachable NEMA 4X display, or the part listed under the order number shown.\u003c\/p\u003e\n\u003cp style=\"margin:0 0 6px\"\u003e\u003cstrong style=\"color:#B3122A\"\u003eControl panel and contactor required, ordered separately.\u003c\/strong\u003e SubMonitor Connect is a component relay installed inside a complete control panel enclosure (Franklin: a customer-provided NEMA 3R panel); its Triac output closes the motor contactor.\u003c\/p\u003e\n\u003cp style=\"margin:0\"\u003e\u003cstrong style=\"color:#B3122A\"\u003eExternal current transformers:\u003c\/strong\u003e required above 135 A; choose the CT kit for your motor current from the table below.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eOverview\u003c\/div\u003e\n\u003cdiv class=\"gs-lead\"\u003e\n\u003cp\u003eSubMonitor Connect is Franklin’s motor and pump protection relay for three-phase motors and pumps, 200 to 600 VAC, 1 to 700 HP. It monitors performance in real time and protects against dry well conditions, clogging, bound pumps and electrical power problems.\u003c\/p\u003e\n\u003cp\u003eSetup takes nine steps: choose Submersible, Surface or Custom and the relay prepopulates its protection parameters. A detachable 32-character, backlit NEMA 4X display can be mounted on the panel front so conditions can be read safely while the motor runs, and the FE Connect app connects over Bluetooth for setup, monitoring and troubleshooting.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background:#E1E3E6;border-left:3px solid #B8BDC4;padding:8px 14px;font-size:11.5px;color:#4A4A4F;margin-top:14px;line-height:1.5\"\u003eGenuine Franklin Electric equipment, factory-new in original packaging — sold and supported by Watermain Supply, an independent industrial supplier.\u003c\/div\u003e\n\u003cdiv style=\"background:#fff;border-left:5px solid #B3122A;padding:15px 18px;margin-top:12px\"\u003e\n\u003cdiv style=\"font-family:Arial Black,Arial,sans-serif;font-size:15px;color:#B3122A;text-transform:uppercase;letter-spacing:1px;margin-bottom:6px\"\u003e12-Month Franklin Electric Warranty\u003c\/div\u003e\n\u003cp style=\"margin:0;font-size:13.5px;color:#4A4A4F;line-height:1.55\"\u003eFranklin warrants these products for \u003cstrong\u003e1 year from the date of installation, but in no event more than 2 years from the date of manufacture\u003c\/strong\u003e. Franklin’s limited warranty does not cover performance affected by abrasive materials, corrosion due to aggressive conditions or improper voltage supply.\u003c\/p\u003e\n\u003cp style=\"margin:6px 0 0;font-size:12px;color:#9B9EA3;line-height:1.5\"\u003eSource: Franklin Electric SubMonitor Connect Owner’s Manual.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eSpecifications\u003c\/div\u003e\n\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct type\u003c\/td\u003e\n\u003ctd\u003ePump and motor protection relay; NEMA open type with NEMA 4X remote-mountable display\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply\u003c\/td\u003e\n\u003ctd\u003e200-600 VAC, 50\/60 Hz, three-phase motors 1-700 HP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent range\u003c\/td\u003e\n\u003ctd\u003e0.1-135 A base unit; 1-1000 A with external CTs (required above 135 A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOverload\u003c\/td\u003e\n\u003ctd\u003eElectronic I2T trip curve, adjustable class 5-30 (default 10), service factor 1.00-2.00 (default 1.15)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnder power (dry run)\u003c\/td\u003e\n\u003ctd\u003eOn\/Off\/Alarm, 1-99% of kW setting (default On, 65%)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOver power\u003c\/td\u003e\n\u003ctd\u003eOn\/Off\/Alarm, 101-200% of kW setting (default On, 125%)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnder \/ over voltage\u003c\/td\u003e\n\u003ctd\u003e80-99% \/ 101-125% of voltage setting (defaults 90% \/ 110%)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGround fault\u003c\/td\u003e\n\u003ctd\u003eUL 1053 certified, adjustable 1-10 A (default 1 A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOther protection\u003c\/td\u003e\n\u003ctd\u003eVoltage phase loss, current phase unbalance, locked rotor, cycle fault, warm start, backspin delay, motor over-temperature (PT100\/PT1000), motor insulation check\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl output\u003c\/td\u003e\n\u003ctd\u003eTriac closing 24-600 VAC Cerus and LS Electric contactors rated to 800 A; other contactors with coil current to 2 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFault relay\u003c\/td\u003e\n\u003ctd\u003eNormally open, rated 1 A at 240 V, closes on fault\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication\u003c\/td\u003e\n\u003ctd\u003eRS-485 Modbus RTU and BACnet MSTP; Bluetooth to the FE Connect app\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFault log\u003c\/td\u003e\n\u003ctd\u003e150 faults with date and time stamp, plus configuration change and start logs; real time clock with 10-year battery backup\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient\u003c\/td\u003e\n\u003ctd\u003eOperating -5 to 140 °F (-20 to 60 °C); storage -5 to 185 °F; 5-95% RH non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApprovals\u003c\/td\u003e\n\u003ctd\u003eUL\/cUL, CSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\n\u003cp style=\"font-size:12.5px;color:#9B9EA3;margin-top:8px;line-height:1.55\"\u003eSource: Franklin Electric SubMonitor Connect spec sheet (M1772 03-23) and catalog M1688, pp. 17-18.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eModels \u0026amp; Ratings\u003c\/div\u003e\n\u003cdiv class=\"gs-lead\"\u003e\n\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eOrder No.\u003c\/th\u003e\n\u003cth\u003eItem\u003c\/th\u003e\n\u003cth\u003eUse\u003c\/th\u003e\n\u003cth\u003eSource\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e5860015010\u003c\/td\u003e\n\u003ctd\u003eSubMonitor Connect — Standard, 1-135 A\u003c\/td\u003e\n\u003ctd\u003ePump and motor protection relay with NEMA 4X remote-mountable display\u003c\/td\u003e\n\u003ctd\u003eM1688 p. 18\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5860005000\u003c\/td\u003e\n\u003ctd\u003eSubMonitor — Standard, 5-350 A\u003c\/td\u003e\n\u003ctd\u003eEarlier SubMonitor three-phase protection unit\u003c\/td\u003e\n\u003ctd\u003eprice list\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5860005110\u003c\/td\u003e\n\u003ctd\u003eSubMonitor Connect — Premium, 1-135 A\u003c\/td\u003e\n\u003ctd\u003ePump and motor protection relay with NEMA 4X remote-mountable display\u003c\/td\u003e\n\u003ctd\u003eM1688 p. 18\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5860005100\u003c\/td\u003e\n\u003ctd\u003eSubMonitor — Premium, 5-350 A\u003c\/td\u003e\n\u003ctd\u003eEarlier SubMonitor three-phase protection unit\u003c\/td\u003e\n\u003ctd\u003eprice list\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5860015160\u003c\/td\u003e\n\u003ctd\u003eDoor Mounting Kit\u003c\/td\u003e\n\u003ctd\u003eSubMonitor Connect option\u003c\/td\u003e\n\u003ctd\u003eM1688 p. 18\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e225225901\u003c\/td\u003e\n\u003ctd\u003eSubMonitor Panel Door Mounting Kit\u003c\/td\u003e\n\u003ctd\u003eReplacement part for the earlier SubMonitor\u003c\/td\u003e\n\u003ctd\u003eprice list\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5860015150\u003c\/td\u003e\n\u003ctd\u003eSubMonitor Connect Remote Display Assembly\u003c\/td\u003e\n\u003ctd\u003eReplacement remote display for SubMonitor Connect\u003c\/td\u003e\n\u003ctd\u003eprice list\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e225190902\u003c\/td\u003e\n\u003ctd\u003eSubMonitor Remote Display Assembly\u003c\/td\u003e\n\u003ctd\u003eReplacement part for the earlier SubMonitor\u003c\/td\u003e\n\u003ctd\u003eprice list\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5860015170\u003c\/td\u003e\n\u003ctd\u003eExternal CTs, 120-270 A\u003c\/td\u003e\n\u003ctd\u003eSubMonitor Connect option; external CTs are required above 135 A\u003c\/td\u003e\n\u003ctd\u003eM1688 p. 18\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5860015180\u003c\/td\u003e\n\u003ctd\u003eExternal CTs, 200-400 A\u003c\/td\u003e\n\u003ctd\u003eSubMonitor Connect option; external CTs are required above 135 A\u003c\/td\u003e\n\u003ctd\u003eM1688 p. 18\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e225210902\u003c\/td\u003e\n\u003ctd\u003eSubMonitor Case Assembly\u003c\/td\u003e\n\u003ctd\u003eReplacement part for the earlier SubMonitor\u003c\/td\u003e\n\u003ctd\u003eprice list\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5860015190\u003c\/td\u003e\n\u003ctd\u003eExternal CTs, 400-1000 A\u003c\/td\u003e\n\u003ctd\u003eSubMonitor Connect option; external CTs are required above 135 A\u003c\/td\u003e\n\u003ctd\u003eM1688 p. 18\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\n\u003cp style=\"font-size:12.5px;color:#9B9EA3;margin-top:8px;line-height:1.55\"\u003eSource: Franklin Electric Submersible Motors, Drives, Controls, Accessories and Parts Price List (M1480), effective 15 Jun 2026 and Franklin Electric Irrigation and Industrial Submersible Pumps Price List (Mi1000), effective 15 Jun 2026. Order numbers are Franklin's; the model or order number ends every option on this page. Descriptions from Franklin Electric Drives, Controls and Protection Pumping Applications Product Catalog (M1688 11-25), p. 18, where shown.\u003c\/p\u003e\n\n\u003cdiv style=\"display:flex;flex-wrap:wrap;gap:10px;margin:22px 0 4px\"\u003e\u003ca href=\"\/pages\/submersible-well-pump-sizing-calculator\" style=\"flex:1 1 200px;text-align:center;display:block;background:#B3122A;color:#ffffff;font-family:Arial Black,Arial,sans-serif;font-size:12px;text-transform:uppercase;letter-spacing:1.2px;padding:11px 18px;text-decoration:none\"\u003eSubmersible Calculator\u003c\/a\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"gs-contact\"\u003eFor engineering-led sizing and selection support or a factory submittal, email \u003ca href=\"mailto:sales@watermainsupply.com\"\u003esales@watermainsupply.com\u003c\/a\u003e or call \u003ca href=\"tel:18885104036\"\u003e1-888.510.4036\u003c\/a\u003e.\u003cbr\u003e© Watermain Supply — A division of E4 Industrial LLC\u003c\/div\u003e\n\u003c\/div\u003e\u003ch5\u003eData Sheet\u003c\/h5\u003e\u003cdiv class=\"gs\"\u003e\u003cdiv class=\"gs-dl\"\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0264\/1913\/4527\/files\/SubMonitor_Connect_Spec_Sheet_M1772.pdf?v=1791090213\" target=\"_blank\" rel=\"noopener\"\u003eSubMonitor Connect Spec Sheet (M1772)\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0264\/1913\/4527\/files\/SubMonitor_Connect_Owners_Manual_250001701.pdf?v=1791090213\" target=\"_blank\" rel=\"noopener\"\u003eSubMonitor Connect Owner’s Manual\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0264\/1913\/4527\/files\/Franklin_Electric_Drives_Controls_Catalog_M1688_SubMonitor-Connect.pdf?v=1791090213\" target=\"_blank\" rel=\"noopener\"\u003eSubMonitor Connect Section, Drives, Controls and Protection Catalog (M1688)\u003c\/a\u003e\n\u003c\/div\u003e\u003c\/div\u003e\u003ch5\u003eVideos\u003c\/h5\u003e\u003cdiv class=\"gs\"\u003e\u003cdiv class=\"gs-sec\" style=\"margin-top:6px\"\u003e\u003cp style=\"font-size:13px;color:#9B9EA3\"\u003eProduct videos are being added to this listing. For a walkthrough in the meantime, email sales@watermainsupply.com.\u003c\/p\u003e\u003c\/div\u003e\u003c\/div\u003e\u003c!-- \/TABS --\u003e","brand":"Franklin Electric","offers":[{"title":"SubMonitor Connect Standard, 1-135 A - 5860015010","offer_id":50562127364271,"sku":"5860015010","price":1922.09,"currency_code":"USD","in_stock":true},{"title":"SubMonitor Standard, 5-350 A - 5860005000","offer_id":50562127397039,"sku":"5860005000","price":1996.86,"currency_code":"USD","in_stock":true},{"title":"SubMonitor Connect Premium, 1-135 A - 5860005110","offer_id":50562127429807,"sku":"5860005110","price":2622.7,"currency_code":"USD","in_stock":true},{"title":"SubMonitor Premium, 5-350 A - 5860005100","offer_id":50562127462575,"sku":"5860005100","price":2648.55,"currency_code":"USD","in_stock":true},{"title":"Door Mounting Kit - 5860015160","offer_id":50562127495343,"sku":"5860015160","price":73.85,"currency_code":"USD","in_stock":true},{"title":"SubMonitor Panel Door Mounting Kit - 225225901","offer_id":50562127528111,"sku":"225225901","price":190.15,"currency_code":"USD","in_stock":true},{"title":"SubMonitor Connect Remote Display Assembly - 5860015150","offer_id":50562127560879,"sku":"5860015150","price":430.15,"currency_code":"USD","in_stock":true},{"title":"SubMonitor Remote Display Assembly - 225190902","offer_id":50562127593647,"sku":"225190902","price":669.47,"currency_code":"USD","in_stock":true},{"title":"External CTs, 120-270A - 5860015170","offer_id":50562127626415,"sku":"5860015170","price":696.24,"currency_code":"USD","in_stock":true},{"title":"External CTs, 200-400A - 5860015180","offer_id":50562127659183,"sku":"5860015180","price":738.7,"currency_code":"USD","in_stock":true},{"title":"SubMonitor Case Assembly - 225210902","offer_id":50562127691951,"sku":"225210902","price":2074.4,"currency_code":"USD","in_stock":true},{"title":"External CTs, 400-1000A - 5860015190","offer_id":50562127724719,"sku":"5860015190","price":2088.24,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0264\/1913\/4527\/files\/5860015010_SubMonitor-Connect_e72df486-9350-459c-99db-b830d1279366.jpg?v=1791091702","url":"https:\/\/watermainsupply.com\/products\/franklin-electric-submonitor-three-phase-motor-protection","provider":"Watermainsupply","version":"1.0","type":"link"}