{"product_id":"duramac-variable-speed-duplex-booster","title":"A.Y. McDonald DuraMAC Variable Speed Duplex Booster - Home, Light Commercial","description":"\u003c!-- TABS --\u003e\n\u003ch5\u003eDescription\u003c\/h5\u003e\n\u003cdiv class=\"gs\"\u003e\n\u003cdiv class=\"gs-head\"\u003e\n\u003cdiv class=\"gs-eyebrow\"\u003eA.Y. McDonald · Booster Pump\u003c\/div\u003e\n\u003cdiv class=\"gs-title\"\u003eDuraMAC Variable Speed Duplex\u003c\/div\u003e\n\u003cdiv class=\"gs-sub\"\u003eTwo A.Y. McDonald VS Booster pumps on one manifold and skid with a 6-gallon in-line pressure tank: double the flow at the same pressure, and a second pump in reserve.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"gs-badges\"\u003e\n\u003cdiv class=\"gs-badge\" style=\"background:#B3122A;color:#FFFFFF;border-color:#B3122A\"\u003e78-79 PSI Max Boost · 40-70 GPM Max Flow\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003e50 PSI Boost at 20 GPM (1 HP) or 40 GPM (2 HP)\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003e25 PSI Boost at 36 GPM (1 HP) or 66 GPM (2 HP)\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003e25-65 PSI Setting\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003e2 x 1 HP or 2 x 2 HP\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003e120V or 230V 1Ph\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003eBuilt-In VFD on Each Pump\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003e6 Gal In-Line Tank on the Manifold\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003eSelf-Priming\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003e120 PSI Max Working Pressure\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003eNSF 61 Compliant Pumps\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003e76-89 lb System\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eOverview\u003c\/div\u003e\n\u003cdiv class=\"gs-lead\"\u003e\n\u003cp\u003eThe DuraMAC Variable Speed Duplex is a packaged booster built by Watermain Supply on two A.Y. McDonald Variable Speed Booster pumps, the 1 HP 17080V022C-1 for homes and the 2 HP 17080V037C-2 for light commercial work. Both pumps sit on one suction and discharge manifold on a common skid, with a 6-gallon A.Y. McDonald in-line diaphragm tank mounted on the manifold.\u003c\/p\u003e\n\u003cp\u003eEach pump carries its own variable frequency drive, pressure sensor, built-in tank and suction check valve, so each holds the set point on its own. Running together they deliver twice the flow of one pump at the same pressure; if one pump is out for service, the other keeps the building in water.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cul\u003e\n\u003cli\u003eTwo VS Booster pumps, each with its own drive and keypad\u003c\/li\u003e\n\u003cli\u003eDouble the flow: up to 40 GPM (1 HP pair) or 70 GPM (2 HP pair)\u003c\/li\u003e\n\u003cli\u003eA pump in reserve: either pump carries the load alone\u003c\/li\u003e\n\u003cli\u003e6-gallon in-line diaphragm tank on the manifold to cut cycling\u003c\/li\u003e\n\u003cli\u003eSelf-priming, stainless pump casing and impellers\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background:#FFFFFF;border:1px solid #C7CBD1;border-top:3px solid #B3122A;padding:12px 16px 12px;margin:16px 0 4px;font-size:13.5px;line-height:1.55;color:#4A4A4F\"\u003e\n\u003cdiv style=\"font-family:Arial Black,Arial,sans-serif;font-size:11px;letter-spacing:1.2px;text-transform:uppercase;color:#B3122A;margin-bottom:8px\"\u003eWhat Ships and What It Needs to Run\u003c\/div\u003e\n\u003cp style=\"margin:0 0 6px\"\u003e\u003cstrong style=\"color:#B3122A\"\u003eIncluded:\u003c\/strong\u003e two A.Y. McDonald VS Booster pumps (each with built-in drive, pressure tank, discharge pressure sensor and suction check valve), the suction and discharge manifold and skid, and a 6-gallon A.Y. McDonald 16006-V3M in-line diaphragm tank mounted on the manifold.\u003c\/p\u003e\n\u003cp style=\"margin:0 0 6px\"\u003e\u003cstrong style=\"color:#B3122A\"\u003ePower, one circuit per pump.\u003c\/strong\u003e Two 120V circuits on the 1 HP duplex (5.6 A each), or two 230V circuits on the 2 HP duplex (5.9 A each).\u003c\/p\u003e\n\u003cp style=\"margin:0\"\u003e\u003cstrong style=\"color:#B3122A\"\u003eSupply and discharge piping, unions and isolation valves:\u003c\/strong\u003e sized to your installation and ordered separately.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background:#E1E3E6;padding:10px 14px;margin:14px 0;font-size:13.5px;color:#4A4A4F\"\u003eGenuine A.Y. McDonald pumps, factory-new in original packaging — sold and supported by Watermain Supply, an independent industrial supplier. Watermain Supply is an Authorized Stocking A.Y. McDonald and Baker Water Systems Distributor.\u003c\/div\u003e\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003e3-Year A.Y. McDonald Pump Warranty\u003c\/div\u003e\n\u003cdiv class=\"gs-lead\"\u003e\u003cp\u003eEach VS Booster pump is covered for 3 years from the date of installation under A.Y. McDonald’s published limited warranty terms. The diaphragm tank carries A.Y. McDonald’s own tank warranty.\u003c\/p\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eTwo Pumps, One Building\u003c\/div\u003e\n\u003cdiv class=\"gs-lead\"\u003e\n\u003cp\u003eTwo pumps hold more pressure at the flow the building draws. With both running, each carries half the water and sits higher on its own curve: the 2 HP pair adds 50 psi at 40 GPM, where one 2 HP pump adds 50 psi at 20 GPM. Pressure at zero flow stays at the single-pump figure, because it is set by the pump model.\u003c\/p\u003e\n\u003cp\u003eThe two pumps run as a set in their booster-set mode (parameter GP01 = 1 on each pump). Both keep the same stop and restart pressures, and each adds a random 0 to 5 second delay when it starts and stops, so the pumps take turns at light demand and both run at the peak.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eSpecifications\u003c\/div\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePumps\u003c\/td\u003e\n\u003ctd\u003e2 x A.Y. McDonald VS Booster: 17080V022C-1 (1 HP) or 17080V037C-2 (2 HP)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSet point\u003c\/td\u003e\n\u003ctd\u003e25 to 65 psi, programmed on each pump’s keypad\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum working pressure\u003c\/td\u003e\n\u003ctd\u003e120 psi, the pump casing rating, not the boost\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePriming\u003c\/td\u003e\n\u003ctd\u003eSelf-priming, check valve on each pump’s suction\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure tank\u003c\/td\u003e\n\u003ctd\u003eBuilt into each pump body, plus a 6-gallon A.Y. McDonald 16006-V3M in-line tank on the manifold\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower\u003c\/td\u003e\n\u003ctd\u003e1 HP: 120V 1Ph, 5.6 A per pump. 2 HP: 230V 1Ph, 5.9 A per pump\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLiquid temperature\u003c\/td\u003e\n\u003ctd\u003e32 °F to 90 °F; ambient up to 104 °F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor\u003c\/td\u003e\n\u003ctd\u003e2-pole induction, insulation class F, UL listed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertification\u003c\/td\u003e\n\u003ctd\u003ePumps in compliance with NSF 61\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eAbout 76 lb (1 HP) and 89 lb (2 HP) as a system, estimated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eModels \u0026amp; Performance — Will It Do What You Need?\u003c\/div\u003e\n\u003cp\u003ePressure added in PSI by both pumps running at full speed, at system flow. Find your model and read across; the first column is the most it can add.\u003c\/p\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003cth\u003e0 GPM (Shut-off)\u003c\/th\u003e\n\u003cth\u003e20 GPM\u003c\/th\u003e\n\u003cth\u003e40 GPM\u003c\/th\u003e\n\u003cth\u003e60 GPM\u003c\/th\u003e\n\u003cth\u003e70 GPM (Max)\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e2 x 17080V022C-1 · 1 HP\u003c\/td\u003e\n\u003ctd\u003e79\u003c\/td\u003e\n\u003ctd\u003e50\u003c\/td\u003e\n\u003ctd\u003e\u003cb\u003e22\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2 x 17080V037C-2 · 2 HP\u003c\/td\u003e\n\u003ctd\u003e78\u003c\/td\u003e\n\u003ctd\u003e65\u003c\/td\u003e\n\u003ctd\u003e49\u003c\/td\u003e\n\u003ctd\u003e32\u003c\/td\u003e\n\u003ctd\u003e22\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003cth\u003eHP\u003c\/th\u003e\n\u003cth\u003eVoltage\u003c\/th\u003e\n\u003cth\u003eAmps\u003c\/th\u003e\n\u003cth\u003eBest operating range\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e2 x 17080V022C-1\u003c\/td\u003e\n\u003ctd\u003e2 x 1 HP\u003c\/td\u003e\n\u003ctd\u003e120V 1Ph\u003c\/td\u003e\n\u003ctd\u003e5.6 A per pump\u003c\/td\u003e\n\u003ctd\u003e12 to 36 GPM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2 x 17080V037C-2\u003c\/td\u003e\n\u003ctd\u003e2 x 2 HP\u003c\/td\u003e\n\u003ctd\u003e230V 1Ph\u003c\/td\u003e\n\u003ctd\u003e5.9 A per pump\u003c\/td\u003e\n\u003ctd\u003e20 to 68 GPM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp\u003e\u003cb\u003eDrawing from a tank or cistern\u003c\/b\u003e — nothing arrives with pressure, so what the pumps add is what you get: set to 50 psi, the 1 HP pair holds it to about 20 GPM and the 2 HP pair to about 40 GPM.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eFed by a city main\u003c\/b\u003e — the pumps add on top of what arrives, but the drives will not hold more than 65 psi in total. On a 40 psi main set to 60 psi they only have to add 20 psi, and they deliver well beyond their tank-fed flow. Incoming pressure turns into extra flow at the same set point.\u003c\/p\u003e\n\u003cp style=\"font-size:12.5px;color:#9B9EA3\"\u003eDerived from A.Y. McDonald’s published single-pump curves in the Baker Water Systems VS Booster brochure at 2 times the flow, pressure unchanged; the pump maker’s own two-pump table is built the same way. Readings are rounded down. Bold = the last point on that model’s curve, its max flow; — = beyond it. Zero flow is the shut-off point, a ceiling and not a working point. Feet of head = PSI × 2.31. The duplex curves are in the image gallery.\u003c\/p\u003e\n\u003cdiv style=\"display:flex;flex-wrap:wrap;gap:10px;margin:22px 0 4px\"\u003e\n\u003ca href=\"\/pages\/booster-pump-sizing-calculator\" style=\"flex:1 1 200px;text-align:center;display:block;background:#B3122A;color:#ffffff;font-family:Arial Black,Arial,sans-serif;font-size:12px;text-transform:uppercase;letter-spacing:1.2px;padding:11px 18px;text-decoration:none\"\u003eBooster Calculator\u003c\/a\u003e\u003ca href=\"\/pages\/pressure-tank-sizing-calculator\" style=\"flex:1 1 200px;text-align:center;display:block;background:#B3122A;color:#ffffff;font-family:Arial Black,Arial,sans-serif;font-size:12px;text-transform:uppercase;letter-spacing:1.2px;padding:11px 18px;text-decoration:none\"\u003eTank Calculator\u003c\/a\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eBefore You Buy — The Limits That Decide the Fit\u003c\/div\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum settable pressure\u003c\/td\u003e\n\u003ctd\u003e65 psi. The drives will not hold more than this in total, whatever arrives at the inlet.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum working pressure\u003c\/td\u003e\n\u003ctd\u003e120 psi. Incoming pressure plus pressure added must stay below this.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSuction\u003c\/td\u003e\n\u003ctd\u003eSelf-priming, check valve on each pump’s suction.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower\u003c\/td\u003e\n\u003ctd\u003eOne circuit per pump: 120V 1Ph on the 1 HP, 230V 1Ph on the 2 HP. Confirm the service before ordering.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePump control\u003c\/td\u003e\n\u003ctd\u003eEach pump runs on its own drive and sensor. Booster-set mode (GP01 = 1) with the same stop and restart pressures on both pumps makes them work as a pair.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWater temperature\u003c\/td\u003e\n\u003ctd\u003e32 °F to 90 °F liquid; ambient to 104 °F. A thermal expansion tank is still required at any storage water heater.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eInstallation Notes\u003c\/div\u003e\n\u003cul\u003e\n\u003cli\u003eSet GP01 = 1 on each pump and enter the same stop pressure (UP01) and restart pressure (UP02) on both.\u003c\/li\u003e\n\u003cli\u003eWith the manifold tank in place, set AP05 = 1 on each pump if the pressure fluctuates.\u003c\/li\u003e\n\u003cli\u003eCharge the tank to 7 psi (0.5 bar) below the restart pressure, with the system drained.\u003c\/li\u003e\n\u003cli\u003eFit isolation valves before and after the set, and keep the supply and discharge pipes no smaller than the manifold connections.\u003c\/li\u003e\n\u003cli\u003eFit a relief valve on the discharge where incoming pressure plus the most the pumps can add would exceed 120 psi.\u003c\/li\u003e\n\u003cli\u003ePrime each pump through its fill plug before the first start.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"font-size:12.5px;color:#9B9EA3\"\u003eFrom the manufacturer’s operating instructions for the two-pump booster set and the VS Booster pump manual.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eApplications\u003c\/div\u003e\n\u003cp\u003eHomes with high demand or two water heaters, small apartment buildings, offices, irrigation and any site that needs a pump in reserve.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eMaterials of Construction\u003c\/div\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePump casing\u003c\/td\u003e\n\u003ctd\u003eStainless steel AISI 304\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePump shaft\u003c\/td\u003e\n\u003ctd\u003eStainless steel AISI 316\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eImpeller\u003c\/td\u003e\n\u003ctd\u003eStainless steel AISI 304\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBuilt-in tank membrane\u003c\/td\u003e\n\u003ctd\u003eButyl\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMechanical seal\u003c\/td\u003e\n\u003ctd\u003eCarbon \/ ceramic, EPDM and stainless steel 316\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"font-size:12.5px;color:#9B9EA3\"\u003ePump components, per the Baker Water Systems VS Booster brochure.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"gs-contact\"\u003eFor engineering-led sizing and selection support or a factory submittal, email \u003ca href=\"mailto:sales@watermainsupply.com\"\u003esales@watermainsupply.com\u003c\/a\u003e or call \u003ca href=\"tel:18885104036\"\u003e1-888.510.4036\u003c\/a\u003e. © Watermain Supply — A division of E4 Industrial LLC\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch5\u003eData Sheet\u003c\/h5\u003e\n\u003cdiv class=\"gs\"\u003e\n\u003cdiv class=\"gs-dl\"\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0264\/1913\/4527\/files\/DuraMac_VS_series_VFD_Booster.pdf?v=1772128222\" rel=\"noopener\" target=\"_blank\"\u003eVariable Speed Booster Brochure\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0264\/1913\/4527\/files\/WMS_DuraMAC_VS_Duplex_Guide.pdf?v=1794795075\" rel=\"noopener\" target=\"_blank\"\u003eDuplex Installation \u0026amp; Setup Guide\u003c\/a\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch5\u003eVideos\u003c\/h5\u003e\n\u003cdiv class=\"gs\"\u003e\n\u003cdiv class=\"gs-sec\" style=\"margin-top:6px\"\u003e\n\u003cdiv style=\"display:grid;grid-template-columns:repeat(auto-fit,minmax(280px,1fr));gap:20px\"\u003e\n\u003cdiv style=\"position:relative;padding-top:56.25%;background:#000\"\u003e\u003ciframe style=\"position:absolute;top:0;left:0;width:100%;height:100%;border:0\" loading=\"lazy\" title=\"YouTube video player - A.Y. McDonald VS Booster 1 HP and 2 HP by Watermain Supply\" src=\"https:\/\/www.youtube.com\/embed\/SpXWxn2EYRg\" allowfullscreen\u003e\u003c\/iframe\u003e\u003c\/div\u003e\n\u003cdiv style=\"position:relative;padding-top:56.25%;background:#000\"\u003e\u003ciframe style=\"position:absolute;top:0;left:0;width:100%;height:100%;border:0\" loading=\"lazy\" title=\"YouTube video player - A.Y. McDonald VS Booster short by Watermain Supply\" src=\"https:\/\/www.youtube.com\/embed\/Oj5NRdjixUw\" allowfullscreen\u003e\u003c\/iframe\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp style=\"font-size:12px;color:#9B9EA3;margin-top:14px\"\u003eVideos are published by Watermain Supply and open in an embedded player. Each covers the VS Booster pump used in this system.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c!-- \/TABS --\u003e","brand":"A.Y. McDonald","offers":[{"title":"79 PSI Max Boost - 40 GPM Max \/ 2 x 1 HP - 120V 1Ph \/ 2 x 17080V022C-1","offer_id":50891645386927,"sku":"6010-033D","price":3402.14,"currency_code":"USD","in_stock":true},{"title":"78 PSI Max Boost - 70 GPM Max \/ 2 x 2 HP - 230V 1Ph \/ 2 x 17080V037C-2","offer_id":50891645419695,"sku":"6010-034D","price":5141.36,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0264\/1913\/4527\/files\/A.Y._McDonald_DuraMAC_Variable_Speed_Duplex_Booster_-_Home_Light_Commercial.png?v=1794795769","url":"https:\/\/watermainsupply.com\/products\/duramac-variable-speed-duplex-booster","provider":"Watermainsupply","version":"1.0","type":"link"}