{"title":"DuraMAC Dual-Mode Commercial Booster Pump","description":"\u003cstyle\u003e\n.dm-wrap{font-family:Arial,Helvetica,sans-serif;color:#1a1a1e;background:#E1E3E6;padding:0;margin:0 -20px;line-height:1.55}\n.dm-wrap *{box-sizing:border-box}\n.dm-hero{background:#4A4A4F;color:#fff;padding:64px 32px;text-align:center;border-bottom:6px solid #B3122A}\n.dm-hero h2{font-family:\"Arial Black\",Arial,sans-serif;font-size:40px;line-height:1.05;margin:0 0 14px;letter-spacing:.5px;text-transform:uppercase}\n.dm-hero h2 span{color:#B3122A}\n.dm-hero p{font-size:17px;max-width:760px;margin:0 auto;color:#C7CBD1}\n.dm-tag{display:inline-block;background:#B3122A;color:#fff;font-family:\"Arial Black\",Arial,sans-serif;font-size:12px;letter-spacing:2px;padding:6px 14px;margin-bottom:18px;text-transform:uppercase}\n.dm-section{padding:48px 28px;max-width:1180px;margin:0 auto}\n.dm-section.alt{background:#fff}\n.dm-h2{font-family:\"Arial Black\",Arial,sans-serif;font-size:28px;color:#4A4A4F;text-transform:uppercase;letter-spacing:.5px;margin:0 0 8px;border-left:6px solid #B3122A;padding-left:14px;line-height:1.1}\n.dm-sub{color:#4A4A4F;font-size:15px;margin:0 0 28px;max-width:820px;padding-left:20px}\n.dm-intro{background:#fff;padding:44px 32px;border:1px solid #C7CBD1;margin:-24px auto 0;max-width:1180px;position:relative;z-index:2;box-shadow:0 2px 6px rgba(0,0,0,.04)}\n.dm-intro p{margin:0 0 12px;font-size:16px;color:#4A4A4F}\n.dm-intro p:last-child{margin-bottom:0}\n.dm-table-wrap{overflow-x:auto;border:1px solid #C7CBD1}\n.dm-table{width:100%;border-collapse:collapse;background:#fff;font-size:14px;min-width:680px}\n.dm-table th{background:#4A4A4F;color:#fff;font-family:\"Arial Black\",Arial,sans-serif;text-transform:uppercase;font-size:12px;letter-spacing:1px;padding:14px 12px;text-align:left;border:1px solid #4A4A4F}\n.dm-table td{padding:12px;border:1px solid #C7CBD1;color:#4A4A4F;vertical-align:top}\n.dm-table tr:nth-child(even) td{background:#E1E3E6}\n.dm-table td:first-child{font-family:\"Arial Black\",Arial,sans-serif;color:#4A4A4F;font-size:13px;text-transform:uppercase;letter-spacing:.5px;background:#fff!important}\n.dm-table tr:nth-child(even) td:first-child{background:#E1E3E6!important}\n.dm-spec{background:#fff;border:1px solid #C7CBD1;border-left:6px solid #B3122A;padding:28px 30px;max-width:1180px;margin:0 auto}\n.dm-spec h3{font-family:\"Arial Black\",Arial,sans-serif;font-size:18px;color:#4A4A4F;text-transform:uppercase;letter-spacing:.5px;margin:0 0 14px}\n.dm-spec ul{margin:0;padding-left:20px;font-size:14.5px;color:#4A4A4F}\n.dm-spec ul li{margin-bottom:8px}\n.dm-spec ul li strong{font-family:\"Arial Black\",Arial,sans-serif;color:#4A4A4F;font-size:12px;text-transform:uppercase;letter-spacing:.5px}\n.dm-btn{display:inline-block;background:#B3122A;color:#fff!important;font-family:\"Arial Black\",Arial,sans-serif;font-size:13px;text-transform:uppercase;letter-spacing:1.5px;padding:11px 18px;text-decoration:none;margin-top:16px;border:0;text-align:center}\n.dm-btn:hover{background:#8a0e20}\n.dm-btn-out{background:#fff;color:#4A4A4F!important;border:2px solid #4A4A4F;padding:9px 16px}\n.dm-btn-out:hover{background:#4A4A4F;color:#fff!important}\n.dm-why{background:#4A4A4F;color:#fff;padding:48px 32px;margin:0 -20px}\n.dm-why-inner{max-width:1180px;margin:0 auto}\n.dm-why h2{font-family:\"Arial Black\",Arial,sans-serif;font-size:28px;text-transform:uppercase;margin:0 0 28px;border-left:6px solid #B3122A;padding-left:14px;line-height:1.1}\n.dm-why-grid{display:grid;grid-template-columns:repeat(auto-fit,minmax(240px,1fr));gap:24px}\n.dm-why-item h4{font-family:\"Arial Black\",Arial,sans-serif;font-size:15px;color:#fff;text-transform:uppercase;letter-spacing:1px;margin:0 0 8px;padding-bottom:6px;border-bottom:2px solid #B3122A;display:inline-block}\n.dm-why-item p{font-size:14px;color:#C7CBD1;margin:0;line-height:1.6}\n.dm-cta{background:#fff;padding:48px 32px;text-align:center;border:1px solid #C7CBD1;max-width:1180px;margin:48px auto 0}\n.dm-cta h2{font-family:\"Arial Black\",Arial,sans-serif;font-size:30px;color:#4A4A4F;text-transform:uppercase;margin:0 0 12px;letter-spacing:.5px}\n.dm-cta p{font-size:16px;color:#4A4A4F;margin:0 0 24px;max-width:680px;margin-left:auto;margin-right:auto}\n.dm-cta-row{display:flex;flex-wrap:wrap;justify-content:center;gap:16px;align-items:center}\n.dm-phone{font-family:\"Arial Black\",Arial,sans-serif;font-size:22px;color:#B3122A;letter-spacing:1px}\n.dm-foot{text-align:center;padding:24px;font-size:12px;color:#9B9EA3;background:#E1E3E6}\n@media(max-width:640px){.dm-hero h2{font-size:27px}.dm-hero{padding:44px 20px}.dm-section{padding:32px 18px}.dm-h2{font-size:22px}.dm-cta h2{font-size:22px}.dm-intro{padding:28px 20px}.dm-why{padding:36px 20px}}\n\u003c\/style\u003e\n\u003cdiv class=\"dm-wrap\"\u003e\n\u003csection class=\"dm-hero\"\u003e\u003cspan class=\"dm-tag\"\u003eCommercial Booster Systems\u003c\/span\u003e\n\u003ch2\u003eDuraMAC Dual-Mode\u003cbr\u003e\u003cspan\u003eCommercial Booster Systems\u003c\/span\u003e\n\u003c\/h2\u003e\n\u003cp\u003eFactory-assembled, packaged booster systems for steady water pressure in light-commercial and multi-unit buildings — configured simplex, duplex or modular and sized to your duty point.\u003c\/p\u003e\n\u003c\/section\u003e\n\u003cdiv class=\"dm-intro\"\u003e\n\u003cp\u003e\u003cstrong style=\"color:#4a4a4f;font-family:'Arial Black',Arial,sans-serif;\"\u003eDuraMAC Dual-Mode\u003c\/strong\u003e commercial boosters from A.Y. McDonald are complete packaged systems — pump, controls and integrated assembly delivered as a single skid, ready to set and connect. They deliver consistent water pressure for light-commercial buildings, apartments, restaurants, small hotels and similar multi-unit demand.\u003c\/p\u003e\n\u003cp\u003eCompare the configurations below, then choose the system that matches your building from the products listed underneath. For larger commercial, high-rise or critical-redundancy applications, ask our engineering-led desk about vertical multistage and engineered booster options.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003csection class=\"dm-section\"\u003e\n\u003ch2 class=\"dm-h2\"\u003eCompare Configurations\u003c\/h2\u003e\n\u003cp class=\"dm-sub\"\u003eAll three share the DuraMAC Dual-Mode platform. The difference is pump count and redundancy — match it to your building's demand profile, then select the system below.\u003c\/p\u003e\n\u003cdiv class=\"dm-table-wrap\"\u003e\n\u003ctable class=\"dm-table\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eConfiguration\u003c\/th\u003e\n\u003cth\u003ePumps\u003c\/th\u003e\n\u003cth\u003eRedundancy\u003c\/th\u003e\n\u003cth\u003eBest Fit\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSimplex\u003c\/td\u003e\n\u003ctd\u003eSingle pump\u003c\/td\u003e\n\u003ctd\u003eNone (continuous duty)\u003c\/td\u003e\n\u003ctd\u003eSmaller buildings, steady predictable demand, budget-conscious installs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDuplex\u003c\/td\u003e\n\u003ctd\u003eTwo pumps, lead\/lag\u003c\/td\u003e\n\u003ctd\u003eStandby backup\u003c\/td\u003e\n\u003ctd\u003eMulti-unit and higher-demand buildings that need uptime and load sharing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModular\u003c\/td\u003e\n\u003ctd\u003eMultiple, staged\u003c\/td\u003e\n\u003ctd\u003eHigher redundancy\u003c\/td\u003e\n\u003ctd\u003eWider or variable flow ranges and buildings planning for growth\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e\n\u003csection class=\"dm-section alt\"\u003e\n\u003ch2 class=\"dm-h2\"\u003eWhat To Send Us\u003c\/h2\u003e\n\u003cp class=\"dm-sub\"\u003eBooster systems are sized to the building, not pulled off a shelf. Give us these and we'll confirm the right configuration, pump count and lead time.\u003c\/p\u003e\n\u003cdiv class=\"dm-spec\"\u003e\n\u003ch3\u003eSizing Checklist\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePeak Flow —\u003c\/strong\u003e design demand in GPM (or fixture units \/ unit count if flow isn't known).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePressure —\u003c\/strong\u003e required boosted (discharge) pressure and available inlet\/suction pressure.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBuilding —\u003c\/strong\u003e number of floors or height, number of units, and use type.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower —\u003c\/strong\u003e available voltage and phase at the install location.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRedundancy —\u003c\/strong\u003e whether standby backup is required for the application.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ca class=\"dm-btn dm-btn-out\" href=\"\/collections\/booster-pumps\"\u003eBrowse All Booster Pumps\u003c\/a\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e\n\u003cdiv class=\"dm-why\"\u003e\n\u003cdiv class=\"dm-why-inner\"\u003e\n\u003ch2\u003eWhy Buy Your Booster System Here\u003c\/h2\u003e\n\u003cdiv class=\"dm-why-grid\"\u003e\n\u003cdiv class=\"dm-why-item\"\u003e\n\u003ch4\u003ePackaged \u0026amp; Ready\u003c\/h4\u003e\n\u003cp\u003eDelivered as a complete factory-assembled system — set it, connect it and commission. No field assembly of components.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"dm-why-item\"\u003e\n\u003ch4\u003eEngineering-Led Sizing\u003c\/h4\u003e\n\u003cp\u003eWe size to your actual flow, pressure and building conditions — not catalog assumptions or guesswork.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"dm-why-item\"\u003e\n\u003ch4\u003eRight-Sized Recommendation\u003c\/h4\u003e\n\u003cp\u003eSimplex, duplex or modular — we'll tell you which fits, and flag when a job needs an engineered system instead.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"dm-why-item\"\u003e\n\u003ch4\u003eTexas-Based Support\u003c\/h4\u003e\n\u003cp\u003eHouston-based distributor with a live technical sales desk, M–F 8 AM to 5 PM, and nationwide delivery.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"dm-why-item\"\u003e\n\u003ch4\u003eSubmittals Included\u003c\/h4\u003e\n\u003cp\u003eSpec sheets and documentation for permitting, plan review and your records.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"dm-why-item\"\u003e\n\u003ch4\u003eParts \u0026amp; Service\u003c\/h4\u003e\n\u003cp\u003eReplacement components and ongoing support for the systems we supply.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"dm-cta\"\u003e\n\u003ch2\u003eLet's Spec Your Booster System\u003c\/h2\u003e\n\u003cp\u003eSend your building's flow, pressure, voltage and redundancy needs and we'll confirm the right DuraMAC Dual-Mode configuration — with pricing and lead time.\u003c\/p\u003e\n\u003cdiv class=\"dm-cta-row\"\u003e\n\u003cspan class=\"dm-phone\"\u003e281.664.8000\u003c\/span\u003e\n\u003ca class=\"dm-btn\" href=\"mailto:sales@watermainsupply.com\"\u003eEmail sales@watermainsupply.com\u003c\/a\u003e\n\u003ca class=\"dm-btn dm-btn-out\" href=\"\/pages\/request-a-quote\"\u003eRequest a Quote\u003c\/a\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"dm-foot\"\u003eDuraMAC and A.Y. McDonald are trademarks of A.Y. McDonald Mfg. Co. Watermain Supply (a DBA of E4 Industrial LLC) is a Houston, TX-based industrial distributor.\u003c\/div\u003e\n\u003c\/div\u003e\n","products":[{"product_id":"dual-mode-modular-commercial-booster-pump-system","title":"Booster Pump | Dual-Mode Modular | Commercial","description":"\u003c!-- TABS --\u003e\n\u003ch5\u003e\u003c!-- TABS --\u003e\u003c\/h5\u003e\n\u003ch5\u003eDescription\u003c\/h5\u003e\n\u003cp\u003e\u003cspan\u003eNot all boosting applications require complicated boosting systems. The DuraMAC™ Boosting system is simple, versatile, sophisticated, and reliable. With an easy setup installation and a versatile control with three modes of operation, this pump is flexible enough to meet your commercial or irrigation needs. \u003cbr\u003e\u003cbr\u003eThe 304 stainless steel version of the DuraMAC™ Booster pump will meet the needs of boosting water pressure from Reverse Osmosis (RO) systems, low PH and other agressive water applications which would be corrosive to no-lead brass and metal pipes.\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eEasy set-up installation\u003c\/li\u003e\n\u003cli\u003eDigital control with dual modes of operation\u003c\/li\u003e\n\u003cli\u003eDurable stainless steel and no-lead brass connections\u003c\/li\u003e\n\u003cli\u003eTEFC single phase motor for quiet operation\u003c\/li\u003e\n\u003cli\u003eElectronics separated and sealed from waterway\u003c\/li\u003e\n\u003cli\u003ePressure gauge included- No-Lead brass check valve included\u003c\/li\u003e\n\u003cli\u003eDesigned for Lead-Lag- Up to 120 GPM\u003c\/li\u003e\n\u003cli\u003e20 gallon pressure tank included\u003c\/li\u003e\n\u003cli\u003eStainless steel base- Dry run protection\u003c\/li\u003e\n\u003cli\u003eStandard, 1 year from install warranty applies\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003ciframe width=\"560\" height=\"315\" src=\"https:\/\/www.youtube.com\/embed\/bOHGjGHrIKs?si=R4WHSk-U0rU7LLAL\" title=\"YouTube video player\"\u003e\u003c\/iframe\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch5\u003eDual Mode Modular Vs Simplex Vs Duplex\u003c\/h5\u003e\n\u003cp\u003e\u003cstrong\u003e1. Dual?Mode Simplex (Commercial)\u003c\/strong\u003e\u003cbr\u003eWhat it is:\u003c\/p\u003e\n\u003cp\u003eOne pump + 20?gallon tank on a skid.\u003cbr\u003eWorks on pressure (dual?mode: pressure or flow logic, but commercial is typically used in pressure mode).\u003cbr\u003eShuts off when flow is less than 3 GPM .\u003cbr\u003eHandles up to ~70 GPM .\u003cbr\u003eWhen to use it:\u003c\/p\u003e\n\u003cp\u003eYou need one pump to handle the building’s demand.\u003cbr\u003eFlow requirement is up to about 70 GPM .\u003cbr\u003eYou want a pre?assembled, ready?to?set unit with tank, skid, and piping already done.\u003cbr\u003eApplication examples:\u003cbr\u003eSmall commercial building\u003cbr\u003eSmaller apartment building\u003cbr\u003eLight industrial where one pump can cover the load and redundancy is not critical.\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e2. Dual?Mode Duplex (Commercial)\u003c\/strong\u003e\u003cbr\u003eWhat it is:\u003c\/p\u003e\n\u003cp\u003eTwo pumps + 20?gallon tank on a skid.\u003cbr\u003eSame dual?mode control concept, but with lead\/lag setup:\u003cbr\u003ePump 1 = lead (e.g., set at 60 PSI).\u003cbr\u003ePump 2 = lag (e.g., set at 50 PSI).\u003cbr\u003eIf the lead pump can’t keep up and pressure drops to the lag setpoint, the second pump starts and they run in tandem .\u003cbr\u003eShuts off when flow is less than 3 GPM .\u003cbr\u003eHandles up to ~120 GPM .\u003cbr\u003eCan be set up so either pump alone can satisfy demand (full redundancy).\u003cbr\u003eWhen to use it:\u003c\/p\u003e\n\u003cp\u003eYou need higher flow than a simplex can provide (up to ~120 GPM).\u003cbr\u003eYou want redundancy \/ backup :\u003cbr\u003eIf one pump or its controls fail, the other can still run the building.\u003cbr\u003eIdeal for:\u003cbr\u003eLarger apartment complexes\u003cbr\u003eFactories or industrial processes\u003cbr\u003eCommercial buildings where downtime is not acceptable and\/or demand can spike above what a single pump can handle.\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e3. Dual?Mode Modular (Commercial)\u003c\/strong\u003e\u003cbr\u003eWhat it is:\u003c\/p\u003e\n\u003cp\u003eSame pump, motor, and control as the simplex\/duplex units, but without :\u003cbr\u003eThe skid\u003cbr\u003eThe tank\u003cbr\u003eThe factory plumbing between tank and outlet\u003cbr\u003eEssentially a “bare” booster package you can plumb into an existing system .\u003cbr\u003eWhen to use it:\u003c\/p\u003e\n\u003cp\u003eYou already have a tank and piping in place and:\u003cbr\u003eDon’t want to replace the tank.\u003cbr\u003eWant to tie a booster into an existing system .\u003cbr\u003eYou want the same performance as a simplex unit but integrated into your own layout .\u003cbr\u003eGood fit when:\u003cbr\u003eA building already has a pressure tank and header, and you’re just adding a booster .\u003cbr\u003eSpace or layout makes a factory skid\/tank package inconvenient.\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePractical selection guide\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003eUse \u003cstrong\u003eDual?Mode Simplex\u003c\/strong\u003e if:\u003cbr\u003eOne pump can handle your flow (? ~70 GPM),\u003cbr\u003eYou want a complete, pre?assembled package with tank and skid,\u003cbr\u003eRedundancy is nice but not critical .\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003eUse \u003cstrong\u003eDual?Mode Duplex\u003c\/strong\u003e if:\u003cbr\u003eYou need more flow (up to ~120 GPM), and\/or\u003cbr\u003eYou need backup so the system can keep running if one pump fails,\u003cbr\u003eYou’re serving larger commercial, industrial, or multi?unit residential loads.\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003eUse \u003cstrong\u003eDual?Mode Modular\u003c\/strong\u003e if:\u003cbr\u003eYou already have a tank and system piping ,\u003cbr\u003eYou just need to add a booster pump into that existing system,\u003cbr\u003eYou don’t want or don’t have room for a full skid\/tank assembly.\u003c\/p\u003e\n\u003ch5\u003eTechnical Details\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003eImpellers: 304 Stainless Steel\u003c\/li\u003e\n\u003cli\u003ePump Casing Inlet: 301 Stainless Steel\u003c\/li\u003e\n\u003cli\u003ePump Casing Outlet: 301 Stainless Steel\u003c\/li\u003e\n\u003cli\u003ePump Seal (stationary): Silicon Carbide\u003c\/li\u003e\n\u003cli\u003ePump Seal (rotating): Carbon \/ NBR\u003c\/li\u003e\n\u003cli\u003eDiffuser: 304 Stainless Steel\u003c\/li\u003e\n\u003cli\u003eUnion Connection: No-Lead Brass\u003c\/li\u003e\n\u003cli\u003eCheck Valve: No-Lead Brass\u003c\/li\u003e\n\u003cli\u003ePump Control: No-Lead Brass\u003c\/li\u003e\n\u003cli\u003eMotor - Single Phase: 2 HP TEFC\u003c\/li\u003e\n\u003cli\u003eBase: 304 Stainless Steel\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eHow it Works\u003c\/h5\u003e\n\u003cp\u003eControl Features\u003c\/p\u003e\n\u003cp\u003eThe DuraMAC™ Dual-Mode control has the flexibility to be run in two different modes.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePressure Mode\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eStart Method: Pressure Drop\u003cbr\u003eStop Method: Low Flow\u003c\/p\u003e\n\u003cp\u003eIn Pressure Mode, the control accurately measures pressure with a pressure transducer and starts the pump at an adjustable start pressure point. The pump will stop when the flow is less than three gallons per minute.\u003c\/p\u003e\n\u003cp\u003eThis smart system will only run the pump when water is in use. There is a preset seven-second delay after water is not flowing past the flow sensor to fully pressurize your system and eliminate water hammer.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFlow Mode\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eStart Method: Water Flow\u003cbr\u003eStop Method: Low Flow\u003c\/p\u003e\n\u003cp\u003eIn Flow Mode, the control will start and stop based on flow, regardless of pressure. This method can be used for systems with minor leaking or when incoming pressure varies. The starting flow rate is approximately five gallons per minute. The pump will stop when the flow is less than three gallons per minute.\u003c\/p\u003e\n\u003ch5\u003eDatasheets\u003c\/h5\u003e\n\u003ctable style=\"border-collapse: collapse; width: 219pt;\" width=\"292\" cellspacing=\"0\" cellpadding=\"0\" border=\"0\"\u003e\n\u003ccolgroup\u003e \u003ccol style=\"mso-width-source: userset; mso-width-alt: 5302; width: 109pt;\" width=\"145\"\u003e \u003ccol style=\"mso-width-source: userset; mso-width-alt: 5376; width: 110pt;\" width=\"147\"\u003e \u003c\/colgroup\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 15.0pt;\" height=\"20\"\u003e\n\u003ctd style=\"height: 15.0pt; width: 109pt;\" width=\"145\" class=\"xl68\" height=\"20\"\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 110pt;\" width=\"147\" class=\"xl68\"\u003e\u003cstrong\u003eProduct variant SKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 15.0pt;\" height=\"20\"\u003e\n\u003ctd style=\"height: 15.0pt;\" height=\"20\"\u003e17060C070PC2-S\u003c\/td\u003e\n\u003ctd class=\"xl71\"\u003e6011-003\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 15.0pt;\" height=\"20\"\u003e\n\u003ctd style=\"height: 15.0pt;\" height=\"20\"\u003e17044C070PC2-S\u003c\/td\u003e\n\u003ctd\u003e6011-001\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 15.0pt;\" height=\"20\"\u003e\n\u003ctd style=\"height: 15.0pt;\" class=\"xl71\" height=\"20\"\u003e17060C120PC2-D\u003c\/td\u003e\n\u003ctd class=\"xl71\"\u003e6011-004\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 15.0pt;\" height=\"20\"\u003e\n\u003ctd style=\"height: 15.0pt;\" class=\"xl71\" height=\"20\"\u003e17044C120PC2-D\u003c\/td\u003e\n\u003ctd class=\"xl71\"\u003e6011-002\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 15.0pt;\" height=\"20\"\u003e\n\u003ctd style=\"height: 15.0pt;\" class=\"xl71\" height=\"20\"\u003e17060C070PC2-M\u003c\/td\u003e\n\u003ctd class=\"xl71\"\u003e6011-006\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 15.0pt;\" height=\"20\"\u003e\n\u003ctd style=\"height: 15.0pt;\" class=\"xl71\" height=\"20\"\u003e17044C070PC2-M\u003c\/td\u003e\n\u003ctd class=\"xl71\"\u003e6011-005\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003ca rel=\"noopener\" title=\"Dual-Mode Duplex Commercial Spec Sheet\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0264\/1913\/4527\/files\/Dual_Mode_Booster.pdf?v=1770226854\" target=\"_blank\"\u003eDual-Mode Commercial Spec Sheet\u003c\/a\u003e\u003c\/p\u003e\n\u003ch5\u003e\n\u003c!-- \/TABS --\u003e\u003cbr\u003e\n\u003c\/h5\u003e\n\u003c!-- \/TABS --\u003e","brand":"A.Y. McDonald","offers":[{"title":"44 PSI \/ 230","offer_id":39594752639151,"sku":"6011-005","price":3555.79,"currency_code":"USD","in_stock":true},{"title":"60 PSI \/ 230","offer_id":39594752671919,"sku":"6011-006","price":3777.28,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0264\/1913\/4527\/products\/Booster_Pump_Dual-Mode_Modular_Commercial_45f4bca9-663d-4596-9bc0-dc57d425f22e.jpg?v=1740977757"},{"product_id":"dual-mode-simplex-commercial-booster-pump-system","title":"Booster Pump | Dual-Mode Simplex | Commercial","description":"\u003c!-- TABS --\u003e\n\u003ch5\u003e\u003c!-- TABS --\u003e\u003c\/h5\u003e\n\u003ch5\u003eDescription\u003c\/h5\u003e\n\u003cp\u003e\u003cspan\u003eNot all boosting applications require complicated boosting systems. The DuraMAC™ Boosting system is simple, versatile, sophisticated, and reliable. With an easy setup installation and a versatile control with three modes of operation, this pump is flexible enough to meet your commercial or irrigation needs. \u003cbr\u003e\u003cbr\u003eThe 304 stainless steel version of the DuraMAC™ Booster pump will meet the needs of boosting water pressure from Reverse Osmosis (RO) systems, low PH and other agressive water applications which would be corrosive to no-lead brass and metal pipes.\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eEasy set-up installation\u003c\/li\u003e\n\u003cli\u003eDigital control with dual modes of operation\u003c\/li\u003e\n\u003cli\u003eDurable stainless steel and no-lead brass connections\u003c\/li\u003e\n\u003cli\u003eTEFC single phase motor for quiet operation\u003c\/li\u003e\n\u003cli\u003eElectronics separated and sealed from waterway\u003c\/li\u003e\n\u003cli\u003ePressure gauge included- No-Lead brass check valve included\u003c\/li\u003e\n\u003cli\u003eDesigned for Lead-Lag- Up to 120 GPM\u003c\/li\u003e\n\u003cli\u003e20 gallon pressure tank included\u003c\/li\u003e\n\u003cli\u003eStainless steel base- Dry run protection\u003c\/li\u003e\n\u003cli\u003eStandard, 1 year from install warranty applies\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003ciframe title=\"YouTube video player\" src=\"https:\/\/www.youtube.com\/embed\/bOHGjGHrIKs?si=R4WHSk-U0rU7LLAL\" height=\"315\" width=\"560\"\u003e\u003c\/iframe\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch5\u003eDual Mode Modular Vs Simplex Vs Duplex\u003c\/h5\u003e\n\u003cp\u003e\u003cstrong\u003e1. Dual?Mode Simplex (Commercial)\u003c\/strong\u003e\u003cbr\u003eWhat it is:\u003c\/p\u003e\n\u003cp\u003eOne pump + 20?gallon tank on a skid.\u003cbr\u003eWorks on pressure (dual?mode: pressure or flow logic, but commercial is typically used in pressure mode).\u003cbr\u003eShuts off when flow is less than 3 GPM .\u003cbr\u003eHandles up to ~70 GPM .\u003cbr\u003eWhen to use it:\u003c\/p\u003e\n\u003cp\u003eYou need one pump to handle the building’s demand.\u003cbr\u003eFlow requirement is up to about 70 GPM .\u003cbr\u003eYou want a pre?assembled, ready?to?set unit with tank, skid, and piping already done.\u003cbr\u003eApplication examples:\u003cbr\u003eSmall commercial building\u003cbr\u003eSmaller apartment building\u003cbr\u003eLight industrial where one pump can cover the load and redundancy is not critical.\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e2. Dual?Mode Duplex (Commercial)\u003c\/strong\u003e\u003cbr\u003eWhat it is:\u003c\/p\u003e\n\u003cp\u003eTwo pumps + 20?gallon tank on a skid.\u003cbr\u003eSame dual?mode control concept, but with lead\/lag setup:\u003cbr\u003ePump 1 = lead (e.g., set at 60 PSI).\u003cbr\u003ePump 2 = lag (e.g., set at 50 PSI).\u003cbr\u003eIf the lead pump can’t keep up and pressure drops to the lag setpoint, the second pump starts and they run in tandem .\u003cbr\u003eShuts off when flow is less than 3 GPM .\u003cbr\u003eHandles up to ~120 GPM .\u003cbr\u003eCan be set up so either pump alone can satisfy demand (full redundancy).\u003cbr\u003eWhen to use it:\u003c\/p\u003e\n\u003cp\u003eYou need higher flow than a simplex can provide (up to ~120 GPM).\u003cbr\u003eYou want redundancy \/ backup :\u003cbr\u003eIf one pump or its controls fail, the other can still run the building.\u003cbr\u003eIdeal for:\u003cbr\u003eLarger apartment complexes\u003cbr\u003eFactories or industrial processes\u003cbr\u003eCommercial buildings where downtime is not acceptable and\/or demand can spike above what a single pump can handle.\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e3. Dual?Mode Modular (Commercial)\u003c\/strong\u003e\u003cbr\u003eWhat it is:\u003c\/p\u003e\n\u003cp\u003eSame pump, motor, and control as the simplex\/duplex units, but without :\u003cbr\u003eThe skid\u003cbr\u003eThe tank\u003cbr\u003eThe factory plumbing between tank and outlet\u003cbr\u003eEssentially a “bare” booster package you can plumb into an existing system .\u003cbr\u003eWhen to use it:\u003c\/p\u003e\n\u003cp\u003eYou already have a tank and piping in place and:\u003cbr\u003eDon’t want to replace the tank.\u003cbr\u003eWant to tie a booster into an existing system .\u003cbr\u003eYou want the same performance as a simplex unit but integrated into your own layout .\u003cbr\u003eGood fit when:\u003cbr\u003eA building already has a pressure tank and header, and you’re just adding a booster .\u003cbr\u003eSpace or layout makes a factory skid\/tank package inconvenient.\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePractical selection guide\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003eUse \u003cstrong\u003eDual?Mode Simplex\u003c\/strong\u003e if:\u003cbr\u003eOne pump can handle your flow (? ~70 GPM),\u003cbr\u003eYou want a complete, pre?assembled package with tank and skid,\u003cbr\u003eRedundancy is nice but not critical .\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003eUse \u003cstrong\u003eDual?Mode Duplex\u003c\/strong\u003e if:\u003cbr\u003eYou need more flow (up to ~120 GPM), and\/or\u003cbr\u003eYou need backup so the system can keep running if one pump fails,\u003cbr\u003eYou’re serving larger commercial, industrial, or multi?unit residential loads.\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003eUse \u003cstrong\u003eDual?Mode Modular\u003c\/strong\u003e if:\u003cbr\u003eYou already have a tank and system piping ,\u003cbr\u003eYou just need to add a booster pump into that existing system,\u003cbr\u003eYou don’t want or don’t have room for a full skid\/tank assembly.\u003c\/p\u003e\n\u003ch5\u003eTechnical Details\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003eImpellers: 304 Stainless Steel\u003c\/li\u003e\n\u003cli\u003ePump Casing Inlet: 301 Stainless Steel\u003c\/li\u003e\n\u003cli\u003ePump Casing Outlet: 301 Stainless Steel\u003c\/li\u003e\n\u003cli\u003ePump Seal (stationary): Silicon Carbide\u003c\/li\u003e\n\u003cli\u003ePump Seal (rotating): Carbon \/ NBR\u003c\/li\u003e\n\u003cli\u003eDiffuser: 304 Stainless Steel\u003c\/li\u003e\n\u003cli\u003eUnion Connection: No-Lead Brass\u003c\/li\u003e\n\u003cli\u003eCheck Valve: No-Lead Brass\u003c\/li\u003e\n\u003cli\u003ePump Control: No-Lead Brass\u003c\/li\u003e\n\u003cli\u003eMotor - Single Phase: 2 HP TEFC\u003c\/li\u003e\n\u003cli\u003eBase: 304 Stainless Steel\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eHow it Works\u003c\/h5\u003e\n\u003cp\u003eControl Features\u003c\/p\u003e\n\u003cp\u003eThe DuraMAC™ Dual-Mode control has the flexibility to be run in two different modes.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePressure Mode\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eStart Method: Pressure Drop\u003cbr\u003eStop Method: Low Flow\u003c\/p\u003e\n\u003cp\u003eIn Pressure Mode, the control accurately measures pressure with a pressure transducer and starts the pump at an adjustable start pressure point. The pump will stop when the flow is less than three gallons per minute.\u003c\/p\u003e\n\u003cp\u003eThis smart system will only run the pump when water is in use. There is a preset seven-second delay after water is not flowing past the flow sensor to fully pressurize your system and eliminate water hammer.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFlow Mode\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eStart Method: Water Flow\u003cbr\u003eStop Method: Low Flow\u003c\/p\u003e\n\u003cp\u003eIn Flow Mode, the control will start and stop based on flow, regardless of pressure. This method can be used for systems with minor leaking or when incoming pressure varies. The starting flow rate is approximately five gallons per minute. The pump will stop when the flow is less than three gallons per minute.\u003c\/p\u003e\n\u003ch5\u003eDatasheets\u003c\/h5\u003e\n\u003ctable border=\"0\" cellpadding=\"0\" cellspacing=\"0\" width=\"292\" style=\"border-collapse: collapse; width: 219pt;\"\u003e\n\u003ccolgroup\u003e \u003ccol width=\"145\" style=\"mso-width-source: userset; mso-width-alt: 5302; width: 109pt;\"\u003e \u003ccol width=\"147\" style=\"mso-width-source: userset; mso-width-alt: 5376; width: 110pt;\"\u003e \u003c\/colgroup\u003e\n\u003ctbody\u003e\n\u003ctr height=\"20\" style=\"height: 15.0pt;\"\u003e\n\u003ctd height=\"20\" class=\"xl68\" width=\"145\" style=\"height: 15.0pt; width: 109pt;\"\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"xl68\" width=\"147\" style=\"width: 110pt;\"\u003e\u003cstrong\u003eProduct variant SKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\" style=\"height: 15.0pt;\"\u003e\n\u003ctd height=\"20\" style=\"height: 15.0pt;\"\u003e17060C070PC2-S\u003c\/td\u003e\n\u003ctd class=\"xl71\"\u003e6011-003\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\" style=\"height: 15.0pt;\"\u003e\n\u003ctd height=\"20\" style=\"height: 15.0pt;\"\u003e17044C070PC2-S\u003c\/td\u003e\n\u003ctd\u003e6011-001\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\" style=\"height: 15.0pt;\"\u003e\n\u003ctd height=\"20\" class=\"xl71\" style=\"height: 15.0pt;\"\u003e17060C120PC2-D\u003c\/td\u003e\n\u003ctd class=\"xl71\"\u003e6011-004\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\" style=\"height: 15.0pt;\"\u003e\n\u003ctd height=\"20\" class=\"xl71\" style=\"height: 15.0pt;\"\u003e17044C120PC2-D\u003c\/td\u003e\n\u003ctd class=\"xl71\"\u003e6011-002\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\" style=\"height: 15.0pt;\"\u003e\n\u003ctd height=\"20\" class=\"xl71\" style=\"height: 15.0pt;\"\u003e17060C070PC2-M\u003c\/td\u003e\n\u003ctd class=\"xl71\"\u003e6011-006\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\" style=\"height: 15.0pt;\"\u003e\n\u003ctd height=\"20\" class=\"xl71\" style=\"height: 15.0pt;\"\u003e17044C070PC2-M\u003c\/td\u003e\n\u003ctd class=\"xl71\"\u003e6011-005\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0264\/1913\/4527\/files\/Dual_Mode_Booster.pdf?v=1770226854\" title=\"Dual-Mode Duplex Commercial Spec Sheet\" rel=\"noopener\" target=\"_blank\"\u003eDual-Mode Commercial Spec Sheet\u003c\/a\u003e\u003c\/p\u003e\n\u003ch5\u003e\n\u003c!-- \/TABS --\u003e\u003cbr\u003e\n\u003c\/h5\u003e\n\u003c!-- \/TABS --\u003e","brand":"A.Y. McDonald","offers":[{"title":"44 PSI \/ 230","offer_id":39594752901295,"sku":"6011-001","price":6142.39,"currency_code":"USD","in_stock":true},{"title":"60 PSI \/ 230","offer_id":39594752934063,"sku":"6011-003","price":7154.61,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0264\/1913\/4527\/products\/Booster_Pump_Simplex_Vertical_Multistage_Variable_Speed_f8c5dac8-ad31-462f-b48d-8dcadddb25fb.jpg?v=1740977756"},{"product_id":"dual-mode-duplex-commercial-booster-pump-system","title":"Booster Pump | Dual-Mode Duplex | Commercial","description":"\u003c!-- TABS --\u003e\n\u003ch5\u003eDescription\u003c\/h5\u003e\n\u003cp\u003e\u003cspan\u003eNot all boosting applications require complicated boosting systems. The DuraMAC™ Boosting system is simple, versatile, sophisticated, and reliable. With an easy setup installation and a versatile control with three modes of operation, this pump is flexible enough to meet your commercial or irrigation needs. \u003cbr\u003e\u003cbr\u003eThe 304 stainless steel version of the DuraMAC™ Booster pump will meet the needs of boosting water pressure from Reverse Osmosis (RO) systems, low PH and other agressive water applications which would be corrosive to no-lead brass and metal pipes.\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eEasy set-up installation\u003c\/li\u003e\n\u003cli\u003eDigital control with dual modes of operation\u003c\/li\u003e\n\u003cli\u003eDurable stainless steel and no-lead brass connections\u003c\/li\u003e\n\u003cli\u003eTEFC single phase motor for quiet operation\u003c\/li\u003e\n\u003cli\u003eElectronics separated and sealed from waterway\u003c\/li\u003e\n\u003cli\u003ePressure gauge included- No-Lead brass check valve included\u003c\/li\u003e\n\u003cli\u003eDesigned for Lead-Lag- Up to 120 GPM\u003c\/li\u003e\n\u003cli\u003e20 gallon pressure tank included\u003c\/li\u003e\n\u003cli\u003eStainless steel base- Dry run protection\u003c\/li\u003e\n\u003cli\u003eStandard, 1 year from install warranty applies\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003ciframe width=\"560\" height=\"315\" src=\"https:\/\/www.youtube.com\/embed\/bOHGjGHrIKs?si=R4WHSk-U0rU7LLAL\" title=\"YouTube video player\"\u003e\u003c\/iframe\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch5\u003eDual Mode Modular Vs Simplex Vs Duplex\u003c\/h5\u003e\n\u003cp\u003e\u003cstrong\u003e1. Dual?Mode Simplex (Commercial)\u003c\/strong\u003e\u003cbr\u003eWhat it is:\u003c\/p\u003e\n\u003cp\u003eOne pump + 20?gallon tank on a skid.\u003cbr\u003eWorks on pressure (dual?mode: pressure or flow logic, but commercial is typically used in pressure mode).\u003cbr\u003eShuts off when flow is less than 3 GPM .\u003cbr\u003eHandles up to ~70 GPM .\u003cbr\u003eWhen to use it:\u003c\/p\u003e\n\u003cp\u003eYou need one pump to handle the building’s demand.\u003cbr\u003eFlow requirement is up to about 70 GPM .\u003cbr\u003eYou want a pre?assembled, ready?to?set unit with tank, skid, and piping already done.\u003cbr\u003eApplication examples:\u003cbr\u003eSmall commercial building\u003cbr\u003eSmaller apartment building\u003cbr\u003eLight industrial where one pump can cover the load and redundancy is not critical.\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e2. Dual?Mode Duplex (Commercial)\u003c\/strong\u003e\u003cbr\u003eWhat it is:\u003c\/p\u003e\n\u003cp\u003eTwo pumps + 20?gallon tank on a skid.\u003cbr\u003eSame dual?mode control concept, but with lead\/lag setup:\u003cbr\u003ePump 1 = lead (e.g., set at 60 PSI).\u003cbr\u003ePump 2 = lag (e.g., set at 50 PSI).\u003cbr\u003eIf the lead pump can’t keep up and pressure drops to the lag setpoint, the second pump starts and they run in tandem .\u003cbr\u003eShuts off when flow is less than 3 GPM .\u003cbr\u003eHandles up to ~120 GPM .\u003cbr\u003eCan be set up so either pump alone can satisfy demand (full redundancy).\u003cbr\u003eWhen to use it:\u003c\/p\u003e\n\u003cp\u003eYou need higher flow than a simplex can provide (up to ~120 GPM).\u003cbr\u003eYou want redundancy \/ backup :\u003cbr\u003eIf one pump or its controls fail, the other can still run the building.\u003cbr\u003eIdeal for:\u003cbr\u003eLarger apartment complexes\u003cbr\u003eFactories or industrial processes\u003cbr\u003eCommercial buildings where downtime is not acceptable and\/or demand can spike above what a single pump can handle.\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e3. Dual?Mode Modular (Commercial)\u003c\/strong\u003e\u003cbr\u003eWhat it is:\u003c\/p\u003e\n\u003cp\u003eSame pump, motor, and control as the simplex\/duplex units, but without :\u003cbr\u003eThe skid\u003cbr\u003eThe tank\u003cbr\u003eThe factory plumbing between tank and outlet\u003cbr\u003eEssentially a “bare” booster package you can plumb into an existing system .\u003cbr\u003eWhen to use it:\u003c\/p\u003e\n\u003cp\u003eYou already have a tank and piping in place and:\u003cbr\u003eDon’t want to replace the tank.\u003cbr\u003eWant to tie a booster into an existing system .\u003cbr\u003eYou want the same performance as a simplex unit but integrated into your own layout .\u003cbr\u003eGood fit when:\u003cbr\u003eA building already has a pressure tank and header, and you’re just adding a booster .\u003cbr\u003eSpace or layout makes a factory skid\/tank package inconvenient.\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePractical selection guide\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003eUse \u003cstrong\u003eDual?Mode Simplex\u003c\/strong\u003e if:\u003cbr\u003eOne pump can handle your flow (? ~70 GPM),\u003cbr\u003eYou want a complete, pre?assembled package with tank and skid,\u003cbr\u003eRedundancy is nice but not critical .\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003eUse \u003cstrong\u003eDual?Mode Duplex\u003c\/strong\u003e if:\u003cbr\u003eYou need more flow (up to ~120 GPM), and\/or\u003cbr\u003eYou need backup so the system can keep running if one pump fails,\u003cbr\u003eYou’re serving larger commercial, industrial, or multi?unit residential loads.\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003eUse \u003cstrong\u003eDual?Mode Modular\u003c\/strong\u003e if:\u003cbr\u003eYou already have a tank and system piping ,\u003cbr\u003eYou just need to add a booster pump into that existing system,\u003cbr\u003eYou don’t want or don’t have room for a full skid\/tank assembly.\u003c\/p\u003e\n\u003ch5\u003eTechnical Details\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003eImpellers: 304 Stainless Steel\u003c\/li\u003e\n\u003cli\u003ePump Casing Inlet: 301 Stainless Steel\u003c\/li\u003e\n\u003cli\u003ePump Casing Outlet: 301 Stainless Steel\u003c\/li\u003e\n\u003cli\u003ePump Seal (stationary): Silicon Carbide\u003c\/li\u003e\n\u003cli\u003ePump Seal (rotating): Carbon \/ NBR\u003c\/li\u003e\n\u003cli\u003eDiffuser: 304 Stainless Steel\u003c\/li\u003e\n\u003cli\u003eUnion Connection: No-Lead Brass\u003c\/li\u003e\n\u003cli\u003eCheck Valve: No-Lead Brass\u003c\/li\u003e\n\u003cli\u003ePump Control: No-Lead Brass\u003c\/li\u003e\n\u003cli\u003eMotor - Single Phase: 2 HP TEFC\u003c\/li\u003e\n\u003cli\u003eBase: 304 Stainless Steel\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eHow it Works\u003c\/h5\u003e\n\u003cp\u003eControl Features\u003c\/p\u003e\n\u003cp\u003eThe DuraMAC™ Dual-Mode control has the flexibility to be run in two different modes.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePressure Mode\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eStart Method: Pressure Drop\u003cbr\u003eStop Method: Low Flow\u003c\/p\u003e\n\u003cp\u003eIn Pressure Mode, the control accurately measures pressure with a pressure transducer and starts the pump at an adjustable start pressure point. The pump will stop when the flow is less than three gallons per minute.\u003c\/p\u003e\n\u003cp\u003eThis smart system will only run the pump when water is in use. There is a preset seven-second delay after water is not flowing past the flow sensor to fully pressurize your system and eliminate water hammer.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFlow Mode\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eStart Method: Water Flow\u003cbr\u003eStop Method: Low Flow\u003c\/p\u003e\n\u003cp\u003eIn Flow Mode, the control will start and stop based on flow, regardless of pressure. This method can be used for systems with minor leaking or when incoming pressure varies. The starting flow rate is approximately five gallons per minute. The pump will stop when the flow is less than three gallons per minute.\u003c\/p\u003e\n\u003ch5\u003eDatasheets\u003c\/h5\u003e\n\u003ctable style=\"border-collapse: collapse; width: 219pt;\" width=\"292\" cellspacing=\"0\" cellpadding=\"0\" border=\"0\"\u003e\n\u003ccolgroup\u003e \u003ccol style=\"mso-width-source: userset; mso-width-alt: 5302; width: 109pt;\" width=\"145\"\u003e \u003ccol style=\"mso-width-source: userset; mso-width-alt: 5376; width: 110pt;\" width=\"147\"\u003e \u003c\/colgroup\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 15.0pt;\" height=\"20\"\u003e\n\u003ctd style=\"height: 15.0pt; width: 109pt;\" width=\"145\" class=\"xl68\" height=\"20\"\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 110pt;\" width=\"147\" class=\"xl68\"\u003e\u003cstrong\u003eProduct variant SKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 15.0pt;\" height=\"20\"\u003e\n\u003ctd style=\"height: 15.0pt;\" height=\"20\"\u003e17060C070PC2-S\u003c\/td\u003e\n\u003ctd class=\"xl71\"\u003e6011-003\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 15.0pt;\" height=\"20\"\u003e\n\u003ctd style=\"height: 15.0pt;\" height=\"20\"\u003e17044C070PC2-S\u003c\/td\u003e\n\u003ctd\u003e6011-001\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 15.0pt;\" height=\"20\"\u003e\n\u003ctd style=\"height: 15.0pt;\" class=\"xl71\" height=\"20\"\u003e17060C120PC2-D\u003c\/td\u003e\n\u003ctd class=\"xl71\"\u003e6011-004\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 15.0pt;\" height=\"20\"\u003e\n\u003ctd style=\"height: 15.0pt;\" class=\"xl71\" height=\"20\"\u003e17044C120PC2-D\u003c\/td\u003e\n\u003ctd class=\"xl71\"\u003e6011-002\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 15.0pt;\" height=\"20\"\u003e\n\u003ctd style=\"height: 15.0pt;\" class=\"xl71\" height=\"20\"\u003e17060C070PC2-M\u003c\/td\u003e\n\u003ctd class=\"xl71\"\u003e6011-006\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 15.0pt;\" height=\"20\"\u003e\n\u003ctd style=\"height: 15.0pt;\" class=\"xl71\" height=\"20\"\u003e17044C070PC2-M\u003c\/td\u003e\n\u003ctd class=\"xl71\"\u003e6011-005\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003ca rel=\"noopener\" title=\"Dual-Mode Duplex Commercial Spec Sheet\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0264\/1913\/4527\/files\/Dual_Mode_Booster.pdf?v=1770226854\" target=\"_blank\"\u003eDual-Mode Commercial Spec Sheet\u003c\/a\u003e\u003c\/p\u003e\n\u003c!-- \/TABS --\u003e","brand":"A.Y. McDonald","offers":[{"title":"44 PSI \/ 230","offer_id":39594752999599,"sku":"6011-002","price":12832.86,"currency_code":"USD","in_stock":true},{"title":"60 PSI \/ 230","offer_id":39594753032367,"sku":"6011-004","price":14462.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0264\/1913\/4527\/products\/Booster_Pump_Dual-Mode_Duplex_Commercial_2f6111c6-4e4e-48a1-b614-03f3f326b4cf.jpg?v=1740977755"}],"url":"https:\/\/watermainsupply.com\/collections\/duramac-dual-mode-commercial-booster-pump.oembed","provider":"Watermainsupply","version":"1.0","type":"link"}