{"title":"Constant Pressure Well Pump Packages","description":null,"products":[{"product_id":"baker-autodrive-variable-frequency-drive","title":"A.Y. McDonald AutoDRIVE Constant Pressure VFD for Submersible Pumps, NEMA 3R","description":"\u003c!-- TABS --\u003e\n\u003ch5\u003eDescription\u003c\/h5\u003e\n\u003cdiv class=\"gs\"\u003e\n\u003cdiv class=\"gs-head\"\u003e\n\u003cdiv class=\"gs-eyebrow\"\u003eA.Y. McDonald · Variable Frequency Drive\u003c\/div\u003e\n\u003cdiv class=\"gs-title\"\u003eAutoDRIVE Constant Pressure Drive\u003c\/div\u003e\n\u003cdiv class=\"gs-sub\"\u003eVariable frequency drive for 4 in submersible pumps: single-phase output to 2 HP, three-phase output to 5 HP, from a single-phase supply.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"gs-badges\"\u003e\n\u003cdiv class=\"gs-badge\"\u003e1\/3-5 HP\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003e115V or 230V Single-Phase Supply\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003eSingle- or Three-Phase Output\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003eConstant Pressure\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003ePressure Switch or Transducer\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003eNEMA 3R Steel Enclosure\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003e95% Efficiency\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003eMade in USA\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003e12.25 x 9.25 x 4.68 in\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003e13 lb Weight\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background:#FFFFFF;border:1px solid #C7CBD1;border-top:3px solid #B3122A;padding:12px 16px 12px;margin:16px 0 4px;font-size:13.5px;line-height:1.55;color:#4A4A4F\"\u003e\n\u003cdiv style=\"font-family:Arial Black,Arial,sans-serif;font-size:11px;letter-spacing:1.2px;text-transform:uppercase;color:#B3122A;margin-bottom:8px\"\u003eWhat Ships and What It Needs to Run\u003c\/div\u003e\n\u003cp style=\"margin:0 0 6px\"\u003e\u003cstrong style=\"color:#B3122A\"\u003eIncluded:\u003c\/strong\u003e the drive in its NEMA 3R enclosure with mounting hardware; SD1-2HP2PS ships with a pressure switch and SD1-2HP2 with a pressure transducer, per the model name.\u003c\/p\u003e\n\u003cp style=\"margin:0 0 6px\"\u003e\u003cstrong style=\"color:#B3122A\"\u003eRequired:\u003c\/strong\u003e a submersible pump and motor matched to the drive (see the compatibility table). The catalog lists no pressure sensor with the SD3 models; the AutoDRIVE pressure transducer is part 6619-028.\u003c\/p\u003e\n\u003cp style=\"margin:0\"\u003e\u003cstrong style=\"color:#B3122A\"\u003eSized at install:\u003c\/strong\u003e supply breaker (table below), wiring, the pressure tank (the drive allows a reduced size) and the pressure relief valve shown in the installation diagram.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eOverview\u003c\/div\u003e\n\u003cdiv class=\"gs-lead\"\u003e\n\u003cp\u003eThe AutoDRIVE holds a constant water pressure by varying the speed of a submersible pump. That allows a smaller pressure tank and a quick, simple installation; constant pressure is set up in 5 steps or less on a large backlit display that stays visible in direct sunlight.\u003c\/p\u003e\n\u003cp\u003eThe SD1 models run 1\/3 to 2 HP single-phase two-wire or three-wire motors from a 115V or 230V supply. The SD3 models take a 230V single-phase supply and run 2, 3 and 5 HP three-phase motors. All are built in the USA in a rugged powder-coated NEMA 3R steel enclosure.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background:#E1E3E6;border-left:3px solid #B8BDC4;padding:8px 14px;font-size:11.5px;color:#4A4A4F;margin-top:14px;line-height:1.5\"\u003eGenuine A.Y. McDonald equipment, factory-new in original packaging — sold and supported by Watermain Supply, an independent industrial supplier. Watermain Supply is an Authorized Stocking A.Y. McDonald and Baker Water Systems Distributor.\u003c\/div\u003e\n\u003cdiv style=\"background:#fff;border-left:5px solid #B3122A;padding:15px 18px;margin-top:12px\"\u003e\n\u003cdiv style=\"font-family:Arial Black,Arial,sans-serif;font-size:15px;color:#B3122A;text-transform:uppercase;letter-spacing:1px;margin-bottom:6px\"\u003eA.Y. McDonald Limited Warranty\u003c\/div\u003e\n\u003cp style=\"margin:0;font-size:13.5px;color:#4A4A4F;line-height:1.55\"\u003eCovered for \u003cstrong\u003e2 years from the date of manufacture or 1 year from the date of installation, whichever comes first\u003c\/strong\u003e, under A.Y. McDonald’s standard limited warranty for Baker products.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eModels \u0026amp; Ratings (60 Hz)\u003c\/div\u003e\n\u003cdiv class=\"gs-lead\"\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003cth\u003ePart No.\u003c\/th\u003e\n\u003cth\u003eMotor HP\u003c\/th\u003e\n\u003cth\u003eSupply\u003c\/th\u003e\n\u003cth\u003eOutput\u003c\/th\u003e\n\u003cth\u003eMotor Style\u003c\/th\u003e\n\u003cth\u003ePressure Sensing\u003c\/th\u003e\n\u003cth\u003eWeight\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSD1-2HP2PS w\/Pressure Switch\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6619-018\u003c\/td\u003e\n\u003ctd\u003e1\/3-2\u003c\/td\u003e\n\u003ctd\u003e115 or 230V 1Ph\u003c\/td\u003e\n\u003ctd\u003e1Ph, equal to input\u003c\/td\u003e\n\u003ctd\u003e2-wire or 3-wire\u003c\/td\u003e\n\u003ctd\u003ePressure switch\u003c\/td\u003e\n\u003ctd\u003e13 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSD1-2HP2 w\/Transducer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6619-019\u003c\/td\u003e\n\u003ctd\u003e1\/3-2\u003c\/td\u003e\n\u003ctd\u003e115 or 230V 1Ph\u003c\/td\u003e\n\u003ctd\u003e1Ph, equal to input\u003c\/td\u003e\n\u003ctd\u003e2-wire or 3-wire\u003c\/td\u003e\n\u003ctd\u003eTransducer\u003c\/td\u003e\n\u003ctd\u003e13 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSD3-2HP2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6619-020\u003c\/td\u003e\n\u003ctd\u003e1\/2-2\u003c\/td\u003e\n\u003ctd\u003e230V 1Ph\u003c\/td\u003e\n\u003ctd\u003e230V 3Ph\u003c\/td\u003e\n\u003ctd\u003e3-wire\u003c\/td\u003e\n\u003ctd\u003eAnalog input\u003c\/td\u003e\n\u003ctd\u003e13 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSD3-3HP2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6619-021\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003ctd\u003e230V 1Ph\u003c\/td\u003e\n\u003ctd\u003e230V 3Ph\u003c\/td\u003e\n\u003ctd\u003e3-wire\u003c\/td\u003e\n\u003ctd\u003eAnalog input\u003c\/td\u003e\n\u003ctd\u003e13 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSD3-5HP2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6619-022\u003c\/td\u003e\n\u003ctd\u003e5\u003c\/td\u003e\n\u003ctd\u003e230V 1Ph\u003c\/td\u003e\n\u003ctd\u003e230V 3Ph\u003c\/td\u003e\n\u003ctd\u003e3-wire\u003c\/td\u003e\n\u003ctd\u003eAnalog input\u003c\/td\u003e\n\u003ctd\u003e13 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"font-size:12.5px;color:#9B9EA3;margin-top:8px;line-height:1.55\"\u003e1 1\/2 HP three-phase assembled units use the SD3-2HP2 drive. The catalog prints 12.25 x 9.25 x 4.68 in and 13 lb for both drive families; its three-phase enclosure drawing shows 17.11 in high and 15 lb. Sources: Pumps by Baker catalog (Sept 2025, rev 3\/26), pp. 131-133 and 141; Baker Pumps and Accessories price list, effective 7\/1\/2026.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eCompatibility\u003c\/div\u003e\n\u003cdiv class=\"gs-lead\"\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003cth\u003ePart No.\u003c\/th\u003e\n\u003cth\u003e115V 2-Wire 1\/2 HP\u003c\/th\u003e\n\u003cth\u003e230V 2-Wire 1\/2-1 1\/2 HP\u003c\/th\u003e\n\u003cth\u003e230V 3-Wire 1Ph 1\/2-2 HP\u003c\/th\u003e\n\u003cth\u003e230V 3Ph 1\/2-2 HP\u003c\/th\u003e\n\u003cth\u003e230V 3Ph 3 HP\u003c\/th\u003e\n\u003cth\u003e230V 3Ph 5 HP\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSD1-2HP2PS\u003c\/td\u003e\n\u003ctd\u003e6619-018\u003c\/td\u003e\n\u003ctd\u003eX\u003c\/td\u003e\n\u003ctd\u003eX\u003c\/td\u003e\n\u003ctd\u003eX\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSD1-2HP2\u003c\/td\u003e\n\u003ctd\u003e6619-019\u003c\/td\u003e\n\u003ctd\u003eX\u003c\/td\u003e\n\u003ctd\u003eX\u003c\/td\u003e\n\u003ctd\u003eX\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSD3-2HP2\u003c\/td\u003e\n\u003ctd\u003e6619-020\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eX\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSD3-3HP2\u003c\/td\u003e\n\u003ctd\u003e6619-021\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eX\u003c\/td\u003e\n\u003ctd\u003eX\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSD3-5HP2\u003c\/td\u003e\n\u003ctd\u003e6619-022\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eX\u003c\/td\u003e\n\u003ctd\u003eX\u003c\/td\u003e\n\u003ctd\u003eX\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"font-size:12.5px;color:#9B9EA3;margin-top:8px;line-height:1.55\"\u003eMotor and drive pairing as printed. Source: Pumps by Baker catalog (Sept 2025, rev 3\/26), p. 141.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eShared Specifications\u003c\/div\u003e\n\u003cdiv class=\"gs-lead\"\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure\u003c\/td\u003e\n\u003ctd\u003eNEMA Type 3R steel, powder coated; outdoor and rainproof; insect guards and pre-cut conduit openings in the bottom; mounting hardware included\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003eLarge backlit graphic display, visible in direct sunlight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSetup\u003c\/td\u003e\n\u003ctd\u003eConstant pressure set up in 5 steps or less\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature\u003c\/td\u003e\n\u003ctd\u003e-4 to 122°F (-20 to 50°C); SD3-5HP2 rated to 104°F (40°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage temperature\u003c\/td\u003e\n\u003ctd\u003e-22 to 140°F (-30 to 60°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAltitude\u003c\/td\u003e\n\u003ctd\u003eDerate by 5°C every 2000 ft above 5500 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEfficiency\u003c\/td\u003e\n\u003ctd\u003e95%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShort circuit withstand rating\u003c\/td\u003e\n\u003ctd\u003e5 kA RMS symmetrical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSingle-phase output models (SD1)\u003c\/td\u003e\n\u003ctd\u003e115 or 230 VAC single-phase input (90-160V, 180-260V); single-phase output equal to input, 5-120 Hz; 1\/3 to 2 HP, 2-wire or 3-wire motors; max input 28 A, max output 16 A; overload 150% for 2 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThree-phase output models (SD3)\u003c\/td\u003e\n\u003ctd\u003e230 VAC single-phase input (190-275V); 230V three-phase output, 5-300 Hz; 2, 3 and 5 HP, 3-wire motors; max input 20 \/ 30 \/ 42 A, max output 11 \/ 13 \/ 22 A; overload 120% for 60 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInputs\u003c\/td\u003e\n\u003ctd\u003eTwo programmable digital inputs; analog inputs for 4-20 mA and 0-5 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower terminals\u003c\/td\u003e\n\u003ctd\u003e14-6 AWG, 10.5 in-lb minimum torque\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency\u003c\/td\u003e\n\u003ctd\u003e60 Hz supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"font-size:12.5px;color:#9B9EA3;margin-top:8px;line-height:1.55\"\u003eSource: Pumps by Baker catalog (Sept 2025, rev 3\/26), pp. 131-133.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eBefore You Order\u003c\/div\u003e\n\u003cdiv class=\"gs-lead\"\u003e\n\u003cp\u003ePick the drive by the motor: single-phase 2-wire or 3-wire motors to 2 HP take an SD1; three-phase 230V motors take the SD3 rated for their horsepower. Size the supply breaker from the table below. The drive is rated to 122°F (104°F for SD3-5HP2) and derates above 5500 ft.\u003c\/p\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSupply\u003c\/th\u003e\n\u003cth\u003eMotor HP\u003c\/th\u003e\n\u003cth\u003eInput Current\u003c\/th\u003e\n\u003cth\u003eFuse \/ Breaker\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e115V\u003c\/td\u003e\n\u003ctd\u003e1\/3\u003c\/td\u003e\n\u003ctd\u003e8 A\u003c\/td\u003e\n\u003ctd\u003e10 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e115V\u003c\/td\u003e\n\u003ctd\u003e1\/2\u003c\/td\u003e\n\u003ctd\u003e14 A\u003c\/td\u003e\n\u003ctd\u003e20 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e115V\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003ctd\u003e28 A\u003c\/td\u003e\n\u003ctd\u003e35 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e230V\u003c\/td\u003e\n\u003ctd\u003e1\/2\u003c\/td\u003e\n\u003ctd\u003e6 A\u003c\/td\u003e\n\u003ctd\u003e10 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e230V\u003c\/td\u003e\n\u003ctd\u003e3\/4\u003c\/td\u003e\n\u003ctd\u003e9 A\u003c\/td\u003e\n\u003ctd\u003e15 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e230V\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003ctd\u003e14 A\u003c\/td\u003e\n\u003ctd\u003e20 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e230V\u003c\/td\u003e\n\u003ctd\u003e1 1\/2\u003c\/td\u003e\n\u003ctd\u003e18 A\u003c\/td\u003e\n\u003ctd\u003e25 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e230V\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e28 A\u003c\/td\u003e\n\u003ctd\u003e35 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e230V\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e20 A\u003c\/td\u003e\n\u003ctd\u003e25 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e230V\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003ctd\u003e30 A\u003c\/td\u003e\n\u003ctd\u003e40 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e230V\u003c\/td\u003e\n\u003ctd\u003e5\u003c\/td\u003e\n\u003ctd\u003e42 A\u003c\/td\u003e\n\u003ctd\u003e55 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"font-size:12.5px;color:#9B9EA3;margin-top:8px;line-height:1.55\"\u003eSource: Pumps by Baker catalog (Sept 2025, rev 3\/26), p. 131.\u003c\/p\u003e\n\u003cdiv style=\"display:flex;flex-wrap:wrap;gap:10px;margin:22px 0 4px\"\u003e\n\u003ca href=\"\/pages\/submersible-well-pump-sizing-calculator\" style=\"flex:1 1 200px;text-align:center;display:block;background:#B3122A;color:#ffffff;font-family:Arial Black,Arial,sans-serif;font-size:12px;text-transform:uppercase;letter-spacing:1.2px;padding:11px 18px;text-decoration:none\"\u003eSubmersible Calculator\u003c\/a\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eService Parts\u003c\/div\u003e\n\u003cdiv class=\"gs-lead\"\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003ePart\u003c\/th\u003e\n\u003cth\u003ePart No.\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure transducer with 10 ft wire\u003c\/td\u003e\n\u003ctd\u003e6619-028\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure switch with wire\u003c\/td\u003e\n\u003ctd\u003e6619-029\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eKeypad\u003c\/td\u003e\n\u003ctd\u003e6619-030\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2 HP inverter board (SD1)\u003c\/td\u003e\n\u003ctd\u003e6619-032\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2 HP inverter board (SD3)\u003c\/td\u003e\n\u003ctd\u003e6619-033\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3 HP inverter board\u003c\/td\u003e\n\u003ctd\u003e6619-034\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5 HP inverter board\u003c\/td\u003e\n\u003ctd\u003e6619-035\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl board, 2, 3 and 5 HP\u003c\/td\u003e\n\u003ctd\u003e6619-036\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"font-size:12.5px;color:#9B9EA3;margin-top:8px;line-height:1.55\"\u003eSource: Pumps by Baker catalog (Sept 2025, rev 3\/26), p. 343.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"gs-contact\"\u003eFor engineering-led sizing and selection support or a factory submittal, email \u003ca href=\"mailto:sales@watermainsupply.com\"\u003esales@watermainsupply.com\u003c\/a\u003e or call \u003ca href=\"tel:18885104036\"\u003e1-888.510.4036\u003c\/a\u003e.\u003cbr\u003e© Watermain Supply — A division of E4 Industrial LLC\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch5\u003eData Sheet\u003c\/h5\u003e\n\u003cdiv class=\"gs\"\u003e\n\u003cdiv class=\"gs-dl\"\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0264\/1913\/4527\/files\/Motors_and_Controls_Guide.pdf?v=1772500309\" target=\"_blank\" rel=\"noopener\"\u003ePumps by Baker Motors and Controls Guide\u003c\/a\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch5\u003eVideos\u003c\/h5\u003e\n\u003cdiv class=\"gs\"\u003e\u003cdiv class=\"gs-sec\" style=\"margin-top:6px\"\u003e\n\u003cp style=\"font-size:13px;color:#9B9EA3\"\u003eProduct videos are being added to this listing. For a walkthrough in the meantime, email sales@watermainsupply.com.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003c!-- \/TABS --\u003e","brand":"A.Y. McDonald","offers":[{"title":"2 HP - 1Ph Output \/ SD1-2HP2PS w\/Pressure Switch","offer_id":46602840703151,"sku":"6619-018","price":925.41,"currency_code":"USD","in_stock":true},{"title":"2 HP - 1Ph Output \/ SD1-2HP2 w\/Transducer","offer_id":46602840735919,"sku":"6619-019","price":1102.27,"currency_code":"USD","in_stock":true},{"title":"2 HP - 3Ph Output \/ SD3-2HP2","offer_id":46602840768687,"sku":"6619-020","price":1269.4,"currency_code":"USD","in_stock":true},{"title":"3 HP - 3Ph Output \/ SD3-3HP2","offer_id":46602840801455,"sku":"6619-021","price":1486.12,"currency_code":"USD","in_stock":true},{"title":"5 HP - 3Ph Output \/ SD3-5HP2","offer_id":46602840834223,"sku":"6619-022","price":2436.32,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0264\/1913\/4527\/files\/AutoDriveVariableFrequencyDrive.png?v=1772500085"},{"product_id":"baker-autopac-j-5-gpm-23000-series","title":"A.Y. McDonald AutoPAC J - 5 GPM 23000 Constant Pressure Pump","description":"\u003c!-- TABS --\u003e\n\u003ch5\u003eDescription\u003c\/h5\u003e\n\u003cdiv class=\"gs\"\u003e\n\u003cdiv class=\"gs-head\"\u003e\n\u003cdiv class=\"gs-eyebrow\"\u003eA.Y. McDonald · Constant Pressure Pump System\u003c\/div\u003e\n\u003cdiv class=\"gs-title\"\u003eAutoPAC J - 5 GPM, 23000 Series\u003c\/div\u003e\n\u003cdiv class=\"gs-sub\"\u003eBaker domestic stainless steel 4 in submersible pump, motor and AutoDRIVE constant pressure drive, 1\/2 to 1 1\/2 HP, 17 builds.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"gs-badges\"\u003e\n\u003cdiv class=\"gs-badge\" style=\"background:#B3122A;color:#FFFFFF;border-color:#B3122A\"\u003e251-582 ft at 5 GPM\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003e1\/2-1 1\/2 HP\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003e230V Single-Phase Supply\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003eAutoDRIVE Constant Pressure VFD\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003ePressure Switch or Transducer Control\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003e829 ft Max Head (Shut-off)\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003e1 1\/4 in NPT Discharge\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003eNEMA 3R Drive Enclosure\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003e42-64 lb Weight\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background:#FFFFFF;border:1px solid #C7CBD1;border-top:3px solid #B3122A;padding:12px 16px 12px;margin:16px 0 4px;font-size:13.5px;line-height:1.55;color:#4A4A4F\"\u003e\n\u003cdiv style=\"font-family:Arial Black,Arial,sans-serif;font-size:11px;letter-spacing:1.2px;text-transform:uppercase;color:#B3122A;margin-bottom:8px\"\u003eWhat Ships and What It Needs to Run\u003c\/div\u003e\n\u003cp style=\"margin:0 0 6px\"\u003e\u003cstrong style=\"color:#B3122A\"\u003eIncluded:\u003c\/strong\u003e the pump end and Baker 4 in motor, assembled, with the AutoDRIVE constant pressure drive matched to the motor, and the pressure switch (APS models) or pressure transducer with 10 ft wire (APT models). The drive model for each build is in the Models table.\u003c\/p\u003e\n\u003cp style=\"margin:0 0 6px\"\u003e\u003cstrong style=\"color:#B3122A\"\u003ePower:\u003c\/strong\u003e 230V single-phase supply from a circuit breaker for every build; the three-phase builds take single-phase power and the drive makes three-phase for the motor. Breaker sizes are under Before You Buy.\u003c\/p\u003e\n\u003cp style=\"margin:0\"\u003e\u003cstrong style=\"color:#B3122A\"\u003eSized at install:\u003c\/strong\u003e drop cable, splice kit and the pressure relief valve shown in the manufacturer’s installation diagram.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eOverview\u003c\/div\u003e\n\u003cdiv class=\"gs-lead\"\u003e\n\u003cp\u003eThe AutoPAC is Baker’s constant pressure well package: a 23000 Series 4 in submersible pump, a Baker motor of the same horsepower, and the AutoDRIVE variable frequency drive. The drive holds a set pressure by changing the pump speed, which allows a smaller pressure tank and a quick, simple installation; setup takes 5 steps or less on the drive’s backlit display.\u003c\/p\u003e\n\u003cp\u003eThis listing is the \u003cstrong\u003eJ - 5 GPM\u003c\/strong\u003e class: 1\/2 to 1 1\/2 HP, with pressure switch and transducer control. The AutoDRIVE is American made and housed in a NEMA 3R steel enclosure rated for outdoor use.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background:#E1E3E6;border-left:3px solid #B8BDC4;padding:8px 14px;font-size:11.5px;color:#4A4A4F;margin-top:14px;line-height:1.5\"\u003eGenuine A.Y. McDonald equipment, factory-new in original packaging — sold and supported by Watermain Supply, an independent industrial supplier. Watermain Supply is an Authorized Stocking A.Y. McDonald and Baker Water Systems Distributor.\u003c\/div\u003e\n\u003cdiv style=\"background:#fff;border-left:5px solid #B3122A;padding:15px 18px;margin-top:12px\"\u003e\n\u003cdiv style=\"font-family:Arial Black,Arial,sans-serif;font-size:15px;color:#B3122A;text-transform:uppercase;letter-spacing:1px;margin-bottom:6px\"\u003eA.Y. McDonald Warranty\u003c\/div\u003e\n\u003cp style=\"margin:0;font-size:13.5px;color:#4A4A4F;line-height:1.55\"\u003ePump and motor: covered for \u003cstrong\u003e5 years from the date of manufacture in potable water applications\u003c\/strong\u003e, and 3 years from the date of manufacture in other applications, under A.Y. McDonald’s published terms for Baker submersible motors and assembled submersible pumps. The AutoDRIVE and pressure control fall under A.Y. McDonald’s standard limited warranty: 2 years from the date of manufacture or 1 year from installation, whichever comes first.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eRoom to Grow\u003c\/div\u003e\n\u003cdiv class=\"gs-lead\"\u003e\n\u003cp\u003eOne pump and one drive per well. Need more head later? Step up in horsepower within the J - 5 GPM class; the drive model changes with the motor (see the Models table). Need more flow? Move to a higher flow class of the AutoPAC 23000 Series; every class uses the same 1 1\/4 in NPT discharge.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eModels \u0026amp; Ratings (60 Hz)\u003c\/div\u003e\n\u003cdiv class=\"gs-lead\"\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003cth\u003ePart No.\u003c\/th\u003e\n\u003cth\u003eHP\u003c\/th\u003e\n\u003cth\u003eMotor\u003c\/th\u003e\n\u003cth\u003eControl\u003c\/th\u003e\n\u003cth\u003eAutoDRIVE\u003c\/th\u003e\n\u003cth\u003eHead at 5 GPM\u003c\/th\u003e\n\u003cth\u003eShut-off Head\u003c\/th\u003e\n\u003cth\u003eWeight\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e23050J2-APS\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6630-583\u003c\/td\u003e\n\u003ctd\u003e1\/2\u003c\/td\u003e\n\u003ctd\u003e230V 1Ph 2-Wire\u003c\/td\u003e\n\u003ctd\u003ePressure Switch\u003c\/td\u003e\n\u003ctd\u003eSD1-2HP2PS\u003c\/td\u003e\n\u003ctd\u003e251 ft\u003c\/td\u003e\n\u003ctd\u003e361 ft\u003c\/td\u003e\n\u003ctd\u003e44 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e23050J2-APT\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6630-577\u003c\/td\u003e\n\u003ctd\u003e1\/2\u003c\/td\u003e\n\u003ctd\u003e230V 1Ph 2-Wire\u003c\/td\u003e\n\u003ctd\u003eTransducer\u003c\/td\u003e\n\u003ctd\u003eSD1-2HP2\u003c\/td\u003e\n\u003ctd\u003e251 ft\u003c\/td\u003e\n\u003ctd\u003e361 ft\u003c\/td\u003e\n\u003ctd\u003e44 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e23050J3-APS\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6630-631\u003c\/td\u003e\n\u003ctd\u003e1\/2\u003c\/td\u003e\n\u003ctd\u003e230V 1Ph 3-Wire\u003c\/td\u003e\n\u003ctd\u003ePressure Switch\u003c\/td\u003e\n\u003ctd\u003eSD1-2HP2PS\u003c\/td\u003e\n\u003ctd\u003e251 ft\u003c\/td\u003e\n\u003ctd\u003e361 ft\u003c\/td\u003e\n\u003ctd\u003e42 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e23050J3-APT\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6630-625\u003c\/td\u003e\n\u003ctd\u003e1\/2\u003c\/td\u003e\n\u003ctd\u003e230V 1Ph 3-Wire\u003c\/td\u003e\n\u003ctd\u003eTransducer\u003c\/td\u003e\n\u003ctd\u003eSD1-2HP2\u003c\/td\u003e\n\u003ctd\u003e251 ft\u003c\/td\u003e\n\u003ctd\u003e361 ft\u003c\/td\u003e\n\u003ctd\u003e42 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e23075J2-APS\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6630-595\u003c\/td\u003e\n\u003ctd\u003e3\/4\u003c\/td\u003e\n\u003ctd\u003e230V 1Ph 2-Wire\u003c\/td\u003e\n\u003ctd\u003ePressure Switch\u003c\/td\u003e\n\u003ctd\u003eSD1-2HP2PS\u003c\/td\u003e\n\u003ctd\u003e363 ft\u003c\/td\u003e\n\u003ctd\u003e512 ft\u003c\/td\u003e\n\u003ctd\u003e47 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e23075J2-APT\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6630-589\u003c\/td\u003e\n\u003ctd\u003e3\/4\u003c\/td\u003e\n\u003ctd\u003e230V 1Ph 2-Wire\u003c\/td\u003e\n\u003ctd\u003eTransducer\u003c\/td\u003e\n\u003ctd\u003eSD1-2HP2\u003c\/td\u003e\n\u003ctd\u003e363 ft\u003c\/td\u003e\n\u003ctd\u003e512 ft\u003c\/td\u003e\n\u003ctd\u003e47 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e23075J3-APS\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6630-643\u003c\/td\u003e\n\u003ctd\u003e3\/4\u003c\/td\u003e\n\u003ctd\u003e230V 1Ph 3-Wire\u003c\/td\u003e\n\u003ctd\u003ePressure Switch\u003c\/td\u003e\n\u003ctd\u003eSD1-2HP2PS\u003c\/td\u003e\n\u003ctd\u003e363 ft\u003c\/td\u003e\n\u003ctd\u003e512 ft\u003c\/td\u003e\n\u003ctd\u003e44 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e23075J3-APT\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6630-637\u003c\/td\u003e\n\u003ctd\u003e3\/4\u003c\/td\u003e\n\u003ctd\u003e230V 1Ph 3-Wire\u003c\/td\u003e\n\u003ctd\u003eTransducer\u003c\/td\u003e\n\u003ctd\u003eSD1-2HP2\u003c\/td\u003e\n\u003ctd\u003e363 ft\u003c\/td\u003e\n\u003ctd\u003e512 ft\u003c\/td\u003e\n\u003ctd\u003e44 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e23100J2-APS\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6630-607\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003ctd\u003e230V 1Ph 2-Wire\u003c\/td\u003e\n\u003ctd\u003ePressure Switch\u003c\/td\u003e\n\u003ctd\u003eSD1-2HP2PS\u003c\/td\u003e\n\u003ctd\u003e443 ft\u003c\/td\u003e\n\u003ctd\u003e649 ft\u003c\/td\u003e\n\u003ctd\u003e55 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e23100J2-APT\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6630-601\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003ctd\u003e230V 1Ph 2-Wire\u003c\/td\u003e\n\u003ctd\u003eTransducer\u003c\/td\u003e\n\u003ctd\u003eSD1-2HP2\u003c\/td\u003e\n\u003ctd\u003e443 ft\u003c\/td\u003e\n\u003ctd\u003e649 ft\u003c\/td\u003e\n\u003ctd\u003e55 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e23100J3-APS\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6630-655\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003ctd\u003e230V 1Ph 3-Wire\u003c\/td\u003e\n\u003ctd\u003ePressure Switch\u003c\/td\u003e\n\u003ctd\u003eSD1-2HP2PS\u003c\/td\u003e\n\u003ctd\u003e443 ft\u003c\/td\u003e\n\u003ctd\u003e649 ft\u003c\/td\u003e\n\u003ctd\u003e54 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e23100J3-APT\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6630-649\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003ctd\u003e230V 1Ph 3-Wire\u003c\/td\u003e\n\u003ctd\u003eTransducer\u003c\/td\u003e\n\u003ctd\u003eSD1-2HP2\u003c\/td\u003e\n\u003ctd\u003e443 ft\u003c\/td\u003e\n\u003ctd\u003e649 ft\u003c\/td\u003e\n\u003ctd\u003e54 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e23150J2-APS\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6630-619\u003c\/td\u003e\n\u003ctd\u003e1 1\/2\u003c\/td\u003e\n\u003ctd\u003e230V 1Ph 2-Wire\u003c\/td\u003e\n\u003ctd\u003ePressure Switch\u003c\/td\u003e\n\u003ctd\u003eSD1-2HP2PS\u003c\/td\u003e\n\u003ctd\u003e582 ft\u003c\/td\u003e\n\u003ctd\u003e829 ft\u003c\/td\u003e\n\u003ctd\u003e64 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e23150J2-APT\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6630-613\u003c\/td\u003e\n\u003ctd\u003e1 1\/2\u003c\/td\u003e\n\u003ctd\u003e230V 1Ph 2-Wire\u003c\/td\u003e\n\u003ctd\u003eTransducer\u003c\/td\u003e\n\u003ctd\u003eSD1-2HP2\u003c\/td\u003e\n\u003ctd\u003e582 ft\u003c\/td\u003e\n\u003ctd\u003e829 ft\u003c\/td\u003e\n\u003ctd\u003e64 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e23150J3-APS\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6630-667\u003c\/td\u003e\n\u003ctd\u003e1 1\/2\u003c\/td\u003e\n\u003ctd\u003e230V 1Ph 3-Wire\u003c\/td\u003e\n\u003ctd\u003ePressure Switch\u003c\/td\u003e\n\u003ctd\u003eSD1-2HP2PS\u003c\/td\u003e\n\u003ctd\u003e582 ft\u003c\/td\u003e\n\u003ctd\u003e829 ft\u003c\/td\u003e\n\u003ctd\u003e63 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e23150J3-APT\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6630-661\u003c\/td\u003e\n\u003ctd\u003e1 1\/2\u003c\/td\u003e\n\u003ctd\u003e230V 1Ph 3-Wire\u003c\/td\u003e\n\u003ctd\u003eTransducer\u003c\/td\u003e\n\u003ctd\u003eSD1-2HP2\u003c\/td\u003e\n\u003ctd\u003e582 ft\u003c\/td\u003e\n\u003ctd\u003e829 ft\u003c\/td\u003e\n\u003ctd\u003e63 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e23150J3Z-APT\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6630-849\u003c\/td\u003e\n\u003ctd\u003e1 1\/2\u003c\/td\u003e\n\u003ctd\u003e230V 3Ph\u003c\/td\u003e\n\u003ctd\u003eTransducer\u003c\/td\u003e\n\u003ctd\u003eSD3-2HP2\u003c\/td\u003e\n\u003ctd\u003e582 ft\u003c\/td\u003e\n\u003ctd\u003e829 ft\u003c\/td\u003e\n\u003ctd\u003e56 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"font-size:12.5px;color:#9B9EA3;margin-top:8px;line-height:1.55\"\u003eHead at 5 GPM is read from the published AutoPAC curve (Pumps by Baker catalog (Sept 2025, rev 3\/26), p. 145), digitized and rounded down. Shut-off head as printed. Drive per the compatibility table on p. 141 (1 1\/2 HP three-phase builds use the SD3-2HP2). Sources: Pumps by Baker catalog (Sept 2025, rev 3\/26), pp. 141-143 and 145; Baker Pumps and Accessories price list, effective 7\/1\/2026.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eShared Specifications\u003c\/div\u003e\n\u003cdiv class=\"gs-lead\"\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eIncluded\u003c\/td\u003e\n\u003ctd\u003ePump end, Baker 4 in motor, AutoDRIVE drive, and pressure switch or transducer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDischarge\u003c\/td\u003e\n\u003ctd\u003e1 1\/4 in NPT (female)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCheck valve\u003c\/td\u003e\n\u003ctd\u003eBuilt in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply\u003c\/td\u003e\n\u003ctd\u003e230V single-phase, 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor\u003c\/td\u003e\n\u003ctd\u003eBaker 4 in submersible motor, matched to the pump end horsepower\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePump diameter\u003c\/td\u003e\n\u003ctd\u003e3 3\/4 in with cable guard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrive enclosure\u003c\/td\u003e\n\u003ctd\u003eNEMA Type 3R steel, 12.25 x 9.25 x 4.68 in, 13 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrive operating temperature\u003c\/td\u003e\n\u003ctd\u003e-4 to 122°F; SD3-5HP2 rated to 104°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrive efficiency\u003c\/td\u003e\n\u003ctd\u003e95%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApp connection\u003c\/td\u003e\n\u003ctd\u003eNone; set up on the drive display\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"font-size:12.5px;color:#9B9EA3;margin-top:8px;line-height:1.55\"\u003eSource: Pumps by Baker catalog (Sept 2025, rev 3\/26), pp. 131-133 and 141-143.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003ePerformance — Will It Do What You Need?\u003c\/div\u003e\n\u003cdiv class=\"gs-lead\"\u003e\n\u003cp\u003e\u003cstrong\u003eTotal head\u003c\/strong\u003e is everything the pump lifts against: the vertical lift from the pumping water level to the discharge, the pressure you set on the drive (2.31 ft for every PSI), and friction in the drop pipe. The drive slows the pump when demand falls, so the curve below is the most the pump delivers at full speed.\u003c\/p\u003e\n\u003cp style=\"margin-bottom:4px\"\u003e\u003cstrong\u003eTotal head in feet, by flow in GPM, at full speed\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eHP (stages)\u003c\/th\u003e\n\u003cth\u003e0\u003c\/th\u003e\n\u003cth\u003e2\u003c\/th\u003e\n\u003cth\u003e4\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003e5\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e6\u003c\/th\u003e\n\u003cth\u003e8\u003c\/th\u003e\n\u003cth\u003e10\u003c\/th\u003e\n\u003cth\u003e12\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e1\/2 HP (13)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e361\u003c\/td\u003e\n\u003ctd\u003e322\u003c\/td\u003e\n\u003ctd\u003e275\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e251\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e223\u003c\/td\u003e\n\u003ctd\u003e162\u003c\/td\u003e\n\u003ctd\u003e93\u003c\/td\u003e\n\u003ctd\u003e19\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e3\/4 HP (18)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e514\u003c\/td\u003e\n\u003ctd\u003e464\u003c\/td\u003e\n\u003ctd\u003e401\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e363\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e324\u003c\/td\u003e\n\u003ctd\u003e234\u003c\/td\u003e\n\u003ctd\u003e133\u003c\/td\u003e\n\u003ctd\u003e32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e1 HP (23)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e651\u003c\/td\u003e\n\u003ctd\u003e582\u003c\/td\u003e\n\u003ctd\u003e492\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e443\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e392\u003c\/td\u003e\n\u003ctd\u003e275\u003c\/td\u003e\n\u003ctd\u003e159\u003c\/td\u003e\n\u003ctd\u003e28\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e1 1\/2 HP (30)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e832\u003c\/td\u003e\n\u003ctd\u003e748\u003c\/td\u003e\n\u003ctd\u003e649\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e582\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e510\u003c\/td\u003e\n\u003ctd\u003e357\u003c\/td\u003e\n\u003ctd\u003e202\u003c\/td\u003e\n\u003ctd\u003e44\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"font-size:12.5px;color:#9B9EA3;margin-top:6px;line-height:1.55\"\u003eDigitized from the published AutoPAC curve in the Pumps by Baker catalog (Sept 2025, rev 3\/26), p. 145, and rounded down. Rated flow (5 GPM) in bold. Zero flow is the shut-off point, a ceiling rather than a working point; — marks flows past the end of that curve.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBest operating range:\u003c\/strong\u003e the published curve shades the most efficient operating range; the catalog prints no figures for it. The curve is in the image gallery.\u003c\/p\u003e\n\u003cdiv style=\"display:flex;flex-wrap:wrap;gap:10px;margin:22px 0 4px\"\u003e\n\u003ca href=\"\/pages\/submersible-well-pump-sizing-calculator\" style=\"flex:1 1 200px;text-align:center;display:block;background:#B3122A;color:#ffffff;font-family:Arial Black,Arial,sans-serif;font-size:12px;text-transform:uppercase;letter-spacing:1.2px;padding:11px 18px;text-decoration:none\"\u003eSubmersible Calculator\u003c\/a\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eBefore You Buy — The Limits That Decide the Fit\u003c\/div\u003e\n\u003cdiv class=\"gs-lead\"\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply\u003c\/td\u003e\n\u003ctd\u003e230V single-phase for every build, from a circuit breaker sized per the table below\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure transducer\u003c\/td\u003e\n\u003ctd\u003eMust be installed upright and vertical (manufacturer note)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrive location\u003c\/td\u003e\n\u003ctd\u003eNEMA 3R enclosure, outdoors or indoors; rated to 122°F (104°F for SD3-5HP2); derate above 5500 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor cooling\u003c\/td\u003e\n\u003ctd\u003e1.0 ft\/sec of water flow past the motor at 95°F; motor rated to 95°F water\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWell size\u003c\/td\u003e\n\u003ctd\u003e4 in casing and larger\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePairing\u003c\/td\u003e\n\u003ctd\u003eOne pump and one drive per well\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"margin:14px 0 4px\"\u003e\u003cstrong\u003eBreaker sizing by motor HP (manufacturer recommendation)\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSupply\u003c\/th\u003e\n\u003cth\u003eMotor HP\u003c\/th\u003e\n\u003cth\u003eInput Current\u003c\/th\u003e\n\u003cth\u003eFuse \/ Breaker\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e230V\u003c\/td\u003e\n\u003ctd\u003e1\/2\u003c\/td\u003e\n\u003ctd\u003e6 A\u003c\/td\u003e\n\u003ctd\u003e10 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e230V\u003c\/td\u003e\n\u003ctd\u003e3\/4\u003c\/td\u003e\n\u003ctd\u003e9 A\u003c\/td\u003e\n\u003ctd\u003e15 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e230V\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003ctd\u003e14 A\u003c\/td\u003e\n\u003ctd\u003e20 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e230V\u003c\/td\u003e\n\u003ctd\u003e1 1\/2\u003c\/td\u003e\n\u003ctd\u003e18 A\u003c\/td\u003e\n\u003ctd\u003e25 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e230V\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e28 A\u003c\/td\u003e\n\u003ctd\u003e35 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e230V\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e20 A\u003c\/td\u003e\n\u003ctd\u003e25 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e230V\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003ctd\u003e30 A\u003c\/td\u003e\n\u003ctd\u003e40 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e230V\u003c\/td\u003e\n\u003ctd\u003e5\u003c\/td\u003e\n\u003ctd\u003e42 A\u003c\/td\u003e\n\u003ctd\u003e55 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"font-size:12.5px;color:#9B9EA3;margin-top:8px;line-height:1.55\"\u003eSource: Pumps by Baker catalog (Sept 2025, rev 3\/26), p. 131.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eMaterials of Construction (Pump)\u003c\/div\u003e\n\u003cdiv class=\"gs-lead\"\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eDischarge\u003c\/td\u003e\n\u003ctd\u003e300 series stainless steel, easy-wrench design with built-in safety eye; threads into the shell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCheck valve\u003c\/td\u003e\n\u003ctd\u003eBaker Diamond Design, easy-out for service\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDischarge bearing\u003c\/td\u003e\n\u003ctd\u003eRubber around the stainless steel shaft; self-lubricating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiffusers\u003c\/td\u003e\n\u003ctd\u003ePolycarbonate, corrosion and abrasion resistant, built for sand handling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eImpellers\u003c\/td\u003e\n\u003ctd\u003eGlass bead acetal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShaft\u003c\/td\u003e\n\u003ctd\u003e7\/16 in 300 series stainless steel, hex drive, each one measured for straightness\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShell\u003c\/td\u003e\n\u003ctd\u003eHeavy stainless steel, threaded at both ends for field service\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable guard\u003c\/td\u003e\n\u003ctd\u003eStainless steel; angled top keeps the leads in place\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor bracket\u003c\/td\u003e\n\u003ctd\u003eStainless steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"font-size:12.5px;color:#9B9EA3;margin-top:8px;line-height:1.55\"\u003eSource: Pumps by Baker catalog (Sept 2025, rev 3\/26), pp. 51-52.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eService Parts\u003c\/div\u003e\n\u003cdiv class=\"gs-lead\"\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003ePart\u003c\/th\u003e\n\u003cth\u003ePart No.\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutoDRIVE pressure transducer with 10 ft wire\u003c\/td\u003e\n\u003ctd\u003e6619-028\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutoDRIVE pressure switch with wire\u003c\/td\u003e\n\u003ctd\u003e6619-029\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutoDRIVE keypad\u003c\/td\u003e\n\u003ctd\u003e6619-030\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"font-size:12.5px;color:#9B9EA3;margin-top:8px;line-height:1.55\"\u003eSource: Pumps by Baker catalog (Sept 2025, rev 3\/26), pp. 142-143.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"gs-contact\"\u003eFor engineering-led sizing and selection support or a factory submittal, email \u003ca href=\"mailto:sales@watermainsupply.com\"\u003esales@watermainsupply.com\u003c\/a\u003e or call \u003ca href=\"tel:18885104036\"\u003e1-888.510.4036\u003c\/a\u003e.\u003cbr\u003e© Watermain Supply — A division of E4 Industrial LLC\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch5\u003eData Sheet\u003c\/h5\u003e\n\u003cdiv class=\"gs\"\u003e\n\u003cdiv class=\"gs-dl\"\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0264\/1913\/4527\/files\/AutoPac_Guide.pdf?v=1772502299\" target=\"_blank\" rel=\"noopener\"\u003ePumps by Baker AutoPac Guide\u003c\/a\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch5\u003eVideos\u003c\/h5\u003e\n\u003cdiv class=\"gs\"\u003e\u003cdiv class=\"gs-sec\" style=\"margin-top:6px\"\u003e\n\u003cp style=\"font-size:13px;color:#9B9EA3\"\u003eProduct videos are being added to this listing. For a walkthrough in the meantime, email sales@watermainsupply.com.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003c!-- \/TABS --\u003e","brand":"A.Y. McDonald","offers":[{"title":"1\/2 HP - 4 in Motor \/ 230V 1Ph 2-Wire \/ Switch - 23050J2-APS - 251 ft at 5 GPM","offer_id":46602926325935,"sku":"6630-583","price":2098.74,"currency_code":"USD","in_stock":true},{"title":"1\/2 HP - 4 in Motor \/ 230V 1Ph 2-Wire \/ Transducer - 23050J2-APT - 251 ft at 5 GPM","offer_id":46602926457007,"sku":"6630-577","price":2277.11,"currency_code":"USD","in_stock":true},{"title":"1\/2 HP - 4 in Motor \/ 230V 1Ph 3-Wire \/ Switch - 23050J3-APS - 251 ft at 5 GPM","offer_id":46602926588079,"sku":"6630-631","price":2012.35,"currency_code":"USD","in_stock":true},{"title":"1\/2 HP - 4 in Motor \/ 230V 1Ph 3-Wire \/ Transducer - 23050J3-APT - 251 ft at 5 GPM","offer_id":46602926719151,"sku":"6630-625","price":2191.76,"currency_code":"USD","in_stock":true},{"title":"3\/4 HP - 4 in Motor \/ 230V 1Ph 2-Wire \/ Switch - 23075J2-APS - 363 ft at 5 GPM","offer_id":46602926358703,"sku":"6630-595","price":2398.26,"currency_code":"USD","in_stock":true},{"title":"3\/4 HP - 4 in Motor \/ 230V 1Ph 2-Wire \/ Transducer - 23075J2-APT - 363 ft at 5 GPM","offer_id":46602926489775,"sku":"6630-589","price":2576.63,"currency_code":"USD","in_stock":true},{"title":"3\/4 HP - 4 in Motor \/ 230V 1Ph 3-Wire \/ Switch - 23075J3-APS - 363 ft at 5 GPM","offer_id":46602926620847,"sku":"6630-643","price":2282.74,"currency_code":"USD","in_stock":true},{"title":"3\/4 HP - 4 in Motor \/ 230V 1Ph 3-Wire \/ Transducer - 23075J3-APT - 363 ft at 5 GPM","offer_id":46602926751919,"sku":"6630-637","price":2461.64,"currency_code":"USD","in_stock":true},{"title":"1 HP - 4 in Motor \/ 230V 1Ph 2-Wire \/ Switch - 23100J2-APS - 443 ft at 5 GPM","offer_id":46602926391471,"sku":"6630-607","price":2767.83,"currency_code":"USD","in_stock":true},{"title":"1 HP - 4 in Motor \/ 230V 1Ph 2-Wire \/ Transducer - 23100J2-APT - 443 ft at 5 GPM","offer_id":46602926522543,"sku":"6630-601","price":2947.25,"currency_code":"USD","in_stock":true},{"title":"1 HP - 4 in Motor \/ 230V 1Ph 3-Wire \/ Switch - 23100J3-APS - 443 ft at 5 GPM","offer_id":46602926653615,"sku":"6630-655","price":2627.79,"currency_code":"USD","in_stock":true},{"title":"1 HP - 4 in Motor \/ 230V 1Ph 3-Wire \/ Transducer - 23100J3-APT - 443 ft at 5 GPM","offer_id":46602926784687,"sku":"6630-649","price":2805.67,"currency_code":"USD","in_stock":true},{"title":"1 1\/2 HP - 4 in Motor \/ 230V 1Ph 2-Wire \/ Switch - 23150J2-APS - 582 ft at 5 GPM","offer_id":46602926424239,"sku":"6630-619","price":3011.65,"currency_code":"USD","in_stock":true},{"title":"1 1\/2 HP - 4 in Motor \/ 230V 1Ph 2-Wire \/ Transducer - 23150J2-APT - 582 ft at 5 GPM","offer_id":46602926555311,"sku":"6630-613","price":3190.54,"currency_code":"USD","in_stock":true},{"title":"1 1\/2 HP - 4 in Motor \/ 230V 1Ph 3-Wire \/ Switch - 23150J3-APS - 582 ft at 5 GPM","offer_id":46602926686383,"sku":"6630-667","price":2827.64,"currency_code":"USD","in_stock":true},{"title":"1 1\/2 HP - 4 in Motor \/ 230V 1Ph 3-Wire \/ Transducer - 23150J3-APT - 582 ft at 5 GPM","offer_id":46602926817455,"sku":"6630-661","price":3006.54,"currency_code":"USD","in_stock":true},{"title":"1 1\/2 HP - 4 in Motor \/ 230V 3Ph \/ Transducer - 23150J3Z-APT - 582 ft at 5 GPM","offer_id":46602926850223,"sku":"6630-849","price":3265.17,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0264\/1913\/4527\/files\/AutoPac_9cfb87e5-0b80-4a42-95a8-72dd888ad3b5.png?v=1772502598"},{"product_id":"baker-autopac-v-7-gpm-23000-series","title":"A.Y. McDonald AutoPAC V - 7 GPM 23000 Constant Pressure Pump","description":"\u003c!-- TABS --\u003e\n\u003ch5\u003eDescription\u003c\/h5\u003e\n\u003cdiv class=\"gs\"\u003e\n\u003cdiv class=\"gs-head\"\u003e\n\u003cdiv class=\"gs-eyebrow\"\u003eA.Y. McDonald · Constant Pressure Pump System\u003c\/div\u003e\n\u003cdiv class=\"gs-title\"\u003eAutoPAC V - 7 GPM, 23000 Series\u003c\/div\u003e\n\u003cdiv class=\"gs-sub\"\u003eBaker domestic stainless steel 4 in submersible pump, motor and AutoDRIVE constant pressure drive, 1\/2 to 2 HP, 20 builds.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"gs-badges\"\u003e\n\u003cdiv class=\"gs-badge\" style=\"background:#B3122A;color:#FFFFFF;border-color:#B3122A\"\u003e211-620 ft at 7 GPM\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003e1\/2-2 HP\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003e230V Single-Phase Supply\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003eAutoDRIVE Constant Pressure VFD\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003ePressure Switch or Transducer Control\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003e896 ft Max Head (Shut-off)\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003e1 1\/4 in NPT Discharge\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003eNEMA 3R Drive Enclosure\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003e41-61 lb Weight\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background:#FFFFFF;border:1px solid #C7CBD1;border-top:3px solid #B3122A;padding:12px 16px 12px;margin:16px 0 4px;font-size:13.5px;line-height:1.55;color:#4A4A4F\"\u003e\n\u003cdiv style=\"font-family:Arial Black,Arial,sans-serif;font-size:11px;letter-spacing:1.2px;text-transform:uppercase;color:#B3122A;margin-bottom:8px\"\u003eWhat Ships and What It Needs to Run\u003c\/div\u003e\n\u003cp style=\"margin:0 0 6px\"\u003e\u003cstrong style=\"color:#B3122A\"\u003eIncluded:\u003c\/strong\u003e the pump end and Baker 4 in motor, assembled, with the AutoDRIVE constant pressure drive matched to the motor, and the pressure switch (APS models) or pressure transducer with 10 ft wire (APT models). The drive model for each build is in the Models table.\u003c\/p\u003e\n\u003cp style=\"margin:0 0 6px\"\u003e\u003cstrong style=\"color:#B3122A\"\u003ePower:\u003c\/strong\u003e 230V single-phase supply from a circuit breaker for every build; the three-phase builds take single-phase power and the drive makes three-phase for the motor. Breaker sizes are under Before You Buy.\u003c\/p\u003e\n\u003cp style=\"margin:0\"\u003e\u003cstrong style=\"color:#B3122A\"\u003eSized at install:\u003c\/strong\u003e drop cable, splice kit and the pressure relief valve shown in the manufacturer’s installation diagram.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eOverview\u003c\/div\u003e\n\u003cdiv class=\"gs-lead\"\u003e\n\u003cp\u003eThe AutoPAC is Baker’s constant pressure well package: a 23000 Series 4 in submersible pump, a Baker motor of the same horsepower, and the AutoDRIVE variable frequency drive. The drive holds a set pressure by changing the pump speed, which allows a smaller pressure tank and a quick, simple installation; setup takes 5 steps or less on the drive’s backlit display.\u003c\/p\u003e\n\u003cp\u003eThis listing is the \u003cstrong\u003eV - 7 GPM\u003c\/strong\u003e class: 1\/2 to 2 HP, with pressure switch and transducer control. The AutoDRIVE is American made and housed in a NEMA 3R steel enclosure rated for outdoor use.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background:#E1E3E6;border-left:3px solid #B8BDC4;padding:8px 14px;font-size:11.5px;color:#4A4A4F;margin-top:14px;line-height:1.5\"\u003eGenuine A.Y. McDonald equipment, factory-new in original packaging — sold and supported by Watermain Supply, an independent industrial supplier. Watermain Supply is an Authorized Stocking A.Y. McDonald and Baker Water Systems Distributor.\u003c\/div\u003e\n\u003cdiv style=\"background:#fff;border-left:5px solid #B3122A;padding:15px 18px;margin-top:12px\"\u003e\n\u003cdiv style=\"font-family:Arial Black,Arial,sans-serif;font-size:15px;color:#B3122A;text-transform:uppercase;letter-spacing:1px;margin-bottom:6px\"\u003eA.Y. McDonald Warranty\u003c\/div\u003e\n\u003cp style=\"margin:0;font-size:13.5px;color:#4A4A4F;line-height:1.55\"\u003ePump and motor: covered for \u003cstrong\u003e5 years from the date of manufacture in potable water applications\u003c\/strong\u003e, and 3 years from the date of manufacture in other applications, under A.Y. McDonald’s published terms for Baker submersible motors and assembled submersible pumps. The AutoDRIVE and pressure control fall under A.Y. McDonald’s standard limited warranty: 2 years from the date of manufacture or 1 year from installation, whichever comes first.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eRoom to Grow\u003c\/div\u003e\n\u003cdiv class=\"gs-lead\"\u003e\n\u003cp\u003eOne pump and one drive per well. Need more head later? Step up in horsepower within the V - 7 GPM class; the drive model changes with the motor (see the Models table). Need more flow? Move to a higher flow class of the AutoPAC 23000 Series; every class uses the same 1 1\/4 in NPT discharge.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eModels \u0026amp; Ratings (60 Hz)\u003c\/div\u003e\n\u003cdiv class=\"gs-lead\"\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003cth\u003ePart No.\u003c\/th\u003e\n\u003cth\u003eHP\u003c\/th\u003e\n\u003cth\u003eMotor\u003c\/th\u003e\n\u003cth\u003eControl\u003c\/th\u003e\n\u003cth\u003eAutoDRIVE\u003c\/th\u003e\n\u003cth\u003eHead at 7 GPM\u003c\/th\u003e\n\u003cth\u003eShut-off Head\u003c\/th\u003e\n\u003cth\u003eWeight\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e23050V2-APS\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6630-584\u003c\/td\u003e\n\u003ctd\u003e1\/2\u003c\/td\u003e\n\u003ctd\u003e230V 1Ph 2-Wire\u003c\/td\u003e\n\u003ctd\u003ePressure Switch\u003c\/td\u003e\n\u003ctd\u003eSD1-2HP2PS\u003c\/td\u003e\n\u003ctd\u003e211 ft\u003c\/td\u003e\n\u003ctd\u003e305 ft\u003c\/td\u003e\n\u003ctd\u003e43 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e23050V2-APT\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6630-578\u003c\/td\u003e\n\u003ctd\u003e1\/2\u003c\/td\u003e\n\u003ctd\u003e230V 1Ph 2-Wire\u003c\/td\u003e\n\u003ctd\u003eTransducer\u003c\/td\u003e\n\u003ctd\u003eSD1-2HP2\u003c\/td\u003e\n\u003ctd\u003e211 ft\u003c\/td\u003e\n\u003ctd\u003e305 ft\u003c\/td\u003e\n\u003ctd\u003e43 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e23050V3-APS\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6630-632\u003c\/td\u003e\n\u003ctd\u003e1\/2\u003c\/td\u003e\n\u003ctd\u003e230V 1Ph 3-Wire\u003c\/td\u003e\n\u003ctd\u003ePressure Switch\u003c\/td\u003e\n\u003ctd\u003eSD1-2HP2PS\u003c\/td\u003e\n\u003ctd\u003e211 ft\u003c\/td\u003e\n\u003ctd\u003e305 ft\u003c\/td\u003e\n\u003ctd\u003e41 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e23050V3-APT\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6630-626\u003c\/td\u003e\n\u003ctd\u003e1\/2\u003c\/td\u003e\n\u003ctd\u003e230V 1Ph 3-Wire\u003c\/td\u003e\n\u003ctd\u003eTransducer\u003c\/td\u003e\n\u003ctd\u003eSD1-2HP2\u003c\/td\u003e\n\u003ctd\u003e211 ft\u003c\/td\u003e\n\u003ctd\u003e305 ft\u003c\/td\u003e\n\u003ctd\u003e41 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e23075V2-APS\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6630-596\u003c\/td\u003e\n\u003ctd\u003e3\/4\u003c\/td\u003e\n\u003ctd\u003e230V 1Ph 2-Wire\u003c\/td\u003e\n\u003ctd\u003ePressure Switch\u003c\/td\u003e\n\u003ctd\u003eSD1-2HP2PS\u003c\/td\u003e\n\u003ctd\u003e293 ft\u003c\/td\u003e\n\u003ctd\u003e416 ft\u003c\/td\u003e\n\u003ctd\u003e46 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e23075V2-APT\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6630-590\u003c\/td\u003e\n\u003ctd\u003e3\/4\u003c\/td\u003e\n\u003ctd\u003e230V 1Ph 2-Wire\u003c\/td\u003e\n\u003ctd\u003eTransducer\u003c\/td\u003e\n\u003ctd\u003eSD1-2HP2\u003c\/td\u003e\n\u003ctd\u003e293 ft\u003c\/td\u003e\n\u003ctd\u003e416 ft\u003c\/td\u003e\n\u003ctd\u003e46 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e23075V3-APS\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6630-644\u003c\/td\u003e\n\u003ctd\u003e3\/4\u003c\/td\u003e\n\u003ctd\u003e230V 1Ph 3-Wire\u003c\/td\u003e\n\u003ctd\u003ePressure Switch\u003c\/td\u003e\n\u003ctd\u003eSD1-2HP2PS\u003c\/td\u003e\n\u003ctd\u003e293 ft\u003c\/td\u003e\n\u003ctd\u003e416 ft\u003c\/td\u003e\n\u003ctd\u003e43 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e23075V3-APT\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6630-638\u003c\/td\u003e\n\u003ctd\u003e3\/4\u003c\/td\u003e\n\u003ctd\u003e230V 1Ph 3-Wire\u003c\/td\u003e\n\u003ctd\u003eTransducer\u003c\/td\u003e\n\u003ctd\u003eSD1-2HP2\u003c\/td\u003e\n\u003ctd\u003e293 ft\u003c\/td\u003e\n\u003ctd\u003e416 ft\u003c\/td\u003e\n\u003ctd\u003e43 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e23100V2-APS\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6630-608\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003ctd\u003e230V 1Ph 2-Wire\u003c\/td\u003e\n\u003ctd\u003ePressure Switch\u003c\/td\u003e\n\u003ctd\u003eSD1-2HP2PS\u003c\/td\u003e\n\u003ctd\u003e382 ft\u003c\/td\u003e\n\u003ctd\u003e548 ft\u003c\/td\u003e\n\u003ctd\u003e52 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e23100V2-APT\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6630-602\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003ctd\u003e230V 1Ph 2-Wire\u003c\/td\u003e\n\u003ctd\u003eTransducer\u003c\/td\u003e\n\u003ctd\u003eSD1-2HP2\u003c\/td\u003e\n\u003ctd\u003e382 ft\u003c\/td\u003e\n\u003ctd\u003e548 ft\u003c\/td\u003e\n\u003ctd\u003e52 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e23100V3-APS\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6630-656\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003ctd\u003e230V 1Ph 3-Wire\u003c\/td\u003e\n\u003ctd\u003ePressure Switch\u003c\/td\u003e\n\u003ctd\u003eSD1-2HP2PS\u003c\/td\u003e\n\u003ctd\u003e382 ft\u003c\/td\u003e\n\u003ctd\u003e548 ft\u003c\/td\u003e\n\u003ctd\u003e51 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e23100V3-APT\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6630-650\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003ctd\u003e230V 1Ph 3-Wire\u003c\/td\u003e\n\u003ctd\u003eTransducer\u003c\/td\u003e\n\u003ctd\u003eSD1-2HP2\u003c\/td\u003e\n\u003ctd\u003e382 ft\u003c\/td\u003e\n\u003ctd\u003e548 ft\u003c\/td\u003e\n\u003ctd\u003e51 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e23150V2-APS\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6630-620\u003c\/td\u003e\n\u003ctd\u003e1 1\/2\u003c\/td\u003e\n\u003ctd\u003e230V 1Ph 2-Wire\u003c\/td\u003e\n\u003ctd\u003ePressure Switch\u003c\/td\u003e\n\u003ctd\u003eSD1-2HP2PS\u003c\/td\u003e\n\u003ctd\u003e483 ft\u003c\/td\u003e\n\u003ctd\u003e695 ft\u003c\/td\u003e\n\u003ctd\u003e59 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e23150V2-APT\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6630-614\u003c\/td\u003e\n\u003ctd\u003e1 1\/2\u003c\/td\u003e\n\u003ctd\u003e230V 1Ph 2-Wire\u003c\/td\u003e\n\u003ctd\u003eTransducer\u003c\/td\u003e\n\u003ctd\u003eSD1-2HP2\u003c\/td\u003e\n\u003ctd\u003e483 ft\u003c\/td\u003e\n\u003ctd\u003e695 ft\u003c\/td\u003e\n\u003ctd\u003e59 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e23150V3-APS\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6630-668\u003c\/td\u003e\n\u003ctd\u003e1 1\/2\u003c\/td\u003e\n\u003ctd\u003e230V 1Ph 3-Wire\u003c\/td\u003e\n\u003ctd\u003ePressure Switch\u003c\/td\u003e\n\u003ctd\u003eSD1-2HP2PS\u003c\/td\u003e\n\u003ctd\u003e483 ft\u003c\/td\u003e\n\u003ctd\u003e695 ft\u003c\/td\u003e\n\u003ctd\u003e58 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e23150V3-APT\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6630-662\u003c\/td\u003e\n\u003ctd\u003e1 1\/2\u003c\/td\u003e\n\u003ctd\u003e230V 1Ph 3-Wire\u003c\/td\u003e\n\u003ctd\u003eTransducer\u003c\/td\u003e\n\u003ctd\u003eSD1-2HP2\u003c\/td\u003e\n\u003ctd\u003e483 ft\u003c\/td\u003e\n\u003ctd\u003e695 ft\u003c\/td\u003e\n\u003ctd\u003e58 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e23150V3Z-APT\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6630-850\u003c\/td\u003e\n\u003ctd\u003e1 1\/2\u003c\/td\u003e\n\u003ctd\u003e230V 3Ph\u003c\/td\u003e\n\u003ctd\u003eTransducer\u003c\/td\u003e\n\u003ctd\u003eSD3-2HP2\u003c\/td\u003e\n\u003ctd\u003e483 ft\u003c\/td\u003e\n\u003ctd\u003e695 ft\u003c\/td\u003e\n\u003ctd\u003e51 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e23200V3-APS\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6630-678\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e230V 1Ph 3-Wire\u003c\/td\u003e\n\u003ctd\u003ePressure Switch\u003c\/td\u003e\n\u003ctd\u003eSD1-2HP2PS\u003c\/td\u003e\n\u003ctd\u003e620 ft\u003c\/td\u003e\n\u003ctd\u003e896 ft\u003c\/td\u003e\n\u003ctd\u003e61 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e23200V3-APT\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6630-673\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e230V 1Ph 3-Wire\u003c\/td\u003e\n\u003ctd\u003eTransducer\u003c\/td\u003e\n\u003ctd\u003eSD1-2HP2\u003c\/td\u003e\n\u003ctd\u003e620 ft\u003c\/td\u003e\n\u003ctd\u003e896 ft\u003c\/td\u003e\n\u003ctd\u003e61 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e23200V3Z-APT\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6630-683\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e230V 3Ph\u003c\/td\u003e\n\u003ctd\u003eTransducer\u003c\/td\u003e\n\u003ctd\u003eSD3-2HP2\u003c\/td\u003e\n\u003ctd\u003e620 ft\u003c\/td\u003e\n\u003ctd\u003e896 ft\u003c\/td\u003e\n\u003ctd\u003e59 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"font-size:12.5px;color:#9B9EA3;margin-top:8px;line-height:1.55\"\u003eHead at 7 GPM is read from the published AutoPAC curve (Pumps by Baker catalog (Sept 2025, rev 3\/26), p. 147), digitized and rounded down. Shut-off head as printed. Drive per the compatibility table on p. 141 (1 1\/2 HP three-phase builds use the SD3-2HP2). Sources: Pumps by Baker catalog (Sept 2025, rev 3\/26), pp. 141-143 and 147; Baker Pumps and Accessories price list, effective 7\/1\/2026.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eShared Specifications\u003c\/div\u003e\n\u003cdiv class=\"gs-lead\"\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eIncluded\u003c\/td\u003e\n\u003ctd\u003ePump end, Baker 4 in motor, AutoDRIVE drive, and pressure switch or transducer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDischarge\u003c\/td\u003e\n\u003ctd\u003e1 1\/4 in NPT (female)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCheck valve\u003c\/td\u003e\n\u003ctd\u003eBuilt in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply\u003c\/td\u003e\n\u003ctd\u003e230V single-phase, 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor\u003c\/td\u003e\n\u003ctd\u003eBaker 4 in submersible motor, matched to the pump end horsepower\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePump diameter\u003c\/td\u003e\n\u003ctd\u003e3 3\/4 in with cable guard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrive enclosure\u003c\/td\u003e\n\u003ctd\u003eNEMA Type 3R steel, 12.25 x 9.25 x 4.68 in, 13 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrive operating temperature\u003c\/td\u003e\n\u003ctd\u003e-4 to 122°F; SD3-5HP2 rated to 104°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrive efficiency\u003c\/td\u003e\n\u003ctd\u003e95%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApp connection\u003c\/td\u003e\n\u003ctd\u003eNone; set up on the drive display\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"font-size:12.5px;color:#9B9EA3;margin-top:8px;line-height:1.55\"\u003eSource: Pumps by Baker catalog (Sept 2025, rev 3\/26), pp. 131-133 and 141-143.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003ePerformance — Will It Do What You Need?\u003c\/div\u003e\n\u003cdiv class=\"gs-lead\"\u003e\n\u003cp\u003e\u003cstrong\u003eTotal head\u003c\/strong\u003e is everything the pump lifts against: the vertical lift from the pumping water level to the discharge, the pressure you set on the drive (2.31 ft for every PSI), and friction in the drop pipe. The drive slows the pump when demand falls, so the curve below is the most the pump delivers at full speed.\u003c\/p\u003e\n\u003cp style=\"margin-bottom:4px\"\u003e\u003cstrong\u003eTotal head in feet, by flow in GPM, at full speed\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eHP (stages)\u003c\/th\u003e\n\u003cth\u003e0\u003c\/th\u003e\n\u003cth\u003e2\u003c\/th\u003e\n\u003cth\u003e4\u003c\/th\u003e\n\u003cth\u003e6\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003e7\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e8\u003c\/th\u003e\n\u003cth\u003e10\u003c\/th\u003e\n\u003cth\u003e12\u003c\/th\u003e\n\u003cth\u003e14\u003c\/th\u003e\n\u003cth\u003e16\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e1\/2 HP (9)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e303\u003c\/td\u003e\n\u003ctd\u003e280\u003c\/td\u003e\n\u003ctd\u003e254\u003c\/td\u003e\n\u003ctd\u003e228\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e211\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e195\u003c\/td\u003e\n\u003ctd\u003e157\u003c\/td\u003e\n\u003ctd\u003e111\u003c\/td\u003e\n\u003ctd\u003e65\u003c\/td\u003e\n\u003ctd\u003e14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e3\/4 HP (12)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e415\u003c\/td\u003e\n\u003ctd\u003e387\u003c\/td\u003e\n\u003ctd\u003e351\u003c\/td\u003e\n\u003ctd\u003e314\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e293\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e270\u003c\/td\u003e\n\u003ctd\u003e220\u003c\/td\u003e\n\u003ctd\u003e163\u003c\/td\u003e\n\u003ctd\u003e101\u003c\/td\u003e\n\u003ctd\u003e26\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e1 HP (16)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e549\u003c\/td\u003e\n\u003ctd\u003e508\u003c\/td\u003e\n\u003ctd\u003e462\u003c\/td\u003e\n\u003ctd\u003e409\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e382\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e352\u003c\/td\u003e\n\u003ctd\u003e284\u003c\/td\u003e\n\u003ctd\u003e210\u003c\/td\u003e\n\u003ctd\u003e119\u003c\/td\u003e\n\u003ctd\u003e27\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e1 1\/2 HP (21)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e695\u003c\/td\u003e\n\u003ctd\u003e639\u003c\/td\u003e\n\u003ctd\u003e581\u003c\/td\u003e\n\u003ctd\u003e519\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e483\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e443\u003c\/td\u003e\n\u003ctd\u003e364\u003c\/td\u003e\n\u003ctd\u003e275\u003c\/td\u003e\n\u003ctd\u003e166\u003c\/td\u003e\n\u003ctd\u003e44\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e2 HP (26)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e896\u003c\/td\u003e\n\u003ctd\u003e833\u003c\/td\u003e\n\u003ctd\u003e754\u003c\/td\u003e\n\u003ctd\u003e668\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e620\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e571\u003c\/td\u003e\n\u003ctd\u003e456\u003c\/td\u003e\n\u003ctd\u003e337\u003c\/td\u003e\n\u003ctd\u003e198\u003c\/td\u003e\n\u003ctd\u003e59\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"font-size:12.5px;color:#9B9EA3;margin-top:6px;line-height:1.55\"\u003eDigitized from the published AutoPAC curve in the Pumps by Baker catalog (Sept 2025, rev 3\/26), p. 147, and rounded down. Rated flow (7 GPM) in bold. Zero flow is the shut-off point, a ceiling rather than a working point; — marks flows past the end of that curve.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBest operating range:\u003c\/strong\u003e the published curve shades the most efficient operating range; the catalog prints no figures for it. The curve is in the image gallery.\u003c\/p\u003e\n\u003cdiv style=\"display:flex;flex-wrap:wrap;gap:10px;margin:22px 0 4px\"\u003e\n\u003ca href=\"\/pages\/submersible-well-pump-sizing-calculator\" style=\"flex:1 1 200px;text-align:center;display:block;background:#B3122A;color:#ffffff;font-family:Arial Black,Arial,sans-serif;font-size:12px;text-transform:uppercase;letter-spacing:1.2px;padding:11px 18px;text-decoration:none\"\u003eSubmersible Calculator\u003c\/a\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eBefore You Buy — The Limits That Decide the Fit\u003c\/div\u003e\n\u003cdiv class=\"gs-lead\"\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply\u003c\/td\u003e\n\u003ctd\u003e230V single-phase for every build, from a circuit breaker sized per the table below\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure transducer\u003c\/td\u003e\n\u003ctd\u003eMust be installed upright and vertical (manufacturer note)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrive location\u003c\/td\u003e\n\u003ctd\u003eNEMA 3R enclosure, outdoors or indoors; rated to 122°F (104°F for SD3-5HP2); derate above 5500 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor cooling\u003c\/td\u003e\n\u003ctd\u003e1.0 ft\/sec of water flow past the motor at 95°F; motor rated to 95°F water\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWell size\u003c\/td\u003e\n\u003ctd\u003e4 in casing and larger\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePairing\u003c\/td\u003e\n\u003ctd\u003eOne pump and one drive per well\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"margin:14px 0 4px\"\u003e\u003cstrong\u003eBreaker sizing by motor HP (manufacturer recommendation)\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSupply\u003c\/th\u003e\n\u003cth\u003eMotor HP\u003c\/th\u003e\n\u003cth\u003eInput Current\u003c\/th\u003e\n\u003cth\u003eFuse \/ Breaker\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e230V\u003c\/td\u003e\n\u003ctd\u003e1\/2\u003c\/td\u003e\n\u003ctd\u003e6 A\u003c\/td\u003e\n\u003ctd\u003e10 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e230V\u003c\/td\u003e\n\u003ctd\u003e3\/4\u003c\/td\u003e\n\u003ctd\u003e9 A\u003c\/td\u003e\n\u003ctd\u003e15 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e230V\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003ctd\u003e14 A\u003c\/td\u003e\n\u003ctd\u003e20 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e230V\u003c\/td\u003e\n\u003ctd\u003e1 1\/2\u003c\/td\u003e\n\u003ctd\u003e18 A\u003c\/td\u003e\n\u003ctd\u003e25 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e230V\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e28 A\u003c\/td\u003e\n\u003ctd\u003e35 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e230V\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e20 A\u003c\/td\u003e\n\u003ctd\u003e25 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e230V\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003ctd\u003e30 A\u003c\/td\u003e\n\u003ctd\u003e40 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e230V\u003c\/td\u003e\n\u003ctd\u003e5\u003c\/td\u003e\n\u003ctd\u003e42 A\u003c\/td\u003e\n\u003ctd\u003e55 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"font-size:12.5px;color:#9B9EA3;margin-top:8px;line-height:1.55\"\u003eSource: Pumps by Baker catalog (Sept 2025, rev 3\/26), p. 131.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eMaterials of Construction (Pump)\u003c\/div\u003e\n\u003cdiv class=\"gs-lead\"\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eDischarge\u003c\/td\u003e\n\u003ctd\u003e300 series stainless steel, easy-wrench design with built-in safety eye; threads into the shell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCheck valve\u003c\/td\u003e\n\u003ctd\u003eBaker Diamond Design, easy-out for service\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDischarge bearing\u003c\/td\u003e\n\u003ctd\u003eRubber around the stainless steel shaft; self-lubricating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiffusers\u003c\/td\u003e\n\u003ctd\u003ePolycarbonate, corrosion and abrasion resistant, built for sand handling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eImpellers\u003c\/td\u003e\n\u003ctd\u003eGlass bead acetal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShaft\u003c\/td\u003e\n\u003ctd\u003e7\/16 in 300 series stainless steel, hex drive, each one measured for straightness\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShell\u003c\/td\u003e\n\u003ctd\u003eHeavy stainless steel, threaded at both ends for field service\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable guard\u003c\/td\u003e\n\u003ctd\u003eStainless steel; angled top keeps the leads in place\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor bracket\u003c\/td\u003e\n\u003ctd\u003eStainless steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"font-size:12.5px;color:#9B9EA3;margin-top:8px;line-height:1.55\"\u003eSource: Pumps by Baker catalog (Sept 2025, rev 3\/26), pp. 51-52.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eService Parts\u003c\/div\u003e\n\u003cdiv class=\"gs-lead\"\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003ePart\u003c\/th\u003e\n\u003cth\u003ePart No.\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutoDRIVE pressure transducer with 10 ft wire\u003c\/td\u003e\n\u003ctd\u003e6619-028\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutoDRIVE pressure switch with wire\u003c\/td\u003e\n\u003ctd\u003e6619-029\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutoDRIVE keypad\u003c\/td\u003e\n\u003ctd\u003e6619-030\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"font-size:12.5px;color:#9B9EA3;margin-top:8px;line-height:1.55\"\u003eSource: Pumps by Baker catalog (Sept 2025, rev 3\/26), pp. 142-143.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"gs-contact\"\u003eFor engineering-led sizing and selection support or a factory submittal, email \u003ca href=\"mailto:sales@watermainsupply.com\"\u003esales@watermainsupply.com\u003c\/a\u003e or call \u003ca href=\"tel:18885104036\"\u003e1-888.510.4036\u003c\/a\u003e.\u003cbr\u003e© Watermain Supply — A division of E4 Industrial LLC\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch5\u003eData Sheet\u003c\/h5\u003e\n\u003cdiv class=\"gs\"\u003e\n\u003cdiv class=\"gs-dl\"\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0264\/1913\/4527\/files\/AutoPac_Guide.pdf?v=1772502299\" target=\"_blank\" rel=\"noopener\"\u003ePumps by Baker AutoPac Guide\u003c\/a\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch5\u003eVideos\u003c\/h5\u003e\n\u003cdiv class=\"gs\"\u003e\u003cdiv class=\"gs-sec\" style=\"margin-top:6px\"\u003e\n\u003cp style=\"font-size:13px;color:#9B9EA3\"\u003eProduct videos are being added to this listing. For a walkthrough in the meantime, email sales@watermainsupply.com.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003c!-- \/TABS --\u003e","brand":"A.Y. McDonald","offers":[{"title":"1\/2 HP - 4 in Motor \/ 230V 1Ph 2-Wire \/ Switch - 23050V2-APS - 211 ft at 7 GPM","offer_id":46602926882991,"sku":"6630-584","price":1946.42,"currency_code":"USD","in_stock":true},{"title":"1\/2 HP - 4 in Motor \/ 230V 1Ph 2-Wire \/ Transducer - 23050V2-APT - 211 ft at 7 GPM","offer_id":46602927014063,"sku":"6630-578","price":2124.8,"currency_code":"USD","in_stock":true},{"title":"1\/2 HP - 4 in Motor \/ 230V 1Ph 3-Wire \/ Switch - 23050V3-APS - 211 ft at 7 GPM","offer_id":46602927145135,"sku":"6630-632","price":1738.95,"currency_code":"USD","in_stock":true},{"title":"1\/2 HP - 4 in Motor \/ 230V 1Ph 3-Wire \/ Transducer - 23050V3-APT - 211 ft at 7 GPM","offer_id":46602927308975,"sku":"6630-626","price":2038.93,"currency_code":"USD","in_stock":true},{"title":"3\/4 HP - 4 in Motor \/ 230V 1Ph 2-Wire \/ Switch - 23075V2-APS - 293 ft at 7 GPM","offer_id":46602926915759,"sku":"6630-596","price":2284.78,"currency_code":"USD","in_stock":true},{"title":"3\/4 HP - 4 in Motor \/ 230V 1Ph 2-Wire \/ Transducer - 23075V2-APT - 293 ft at 7 GPM","offer_id":46602927046831,"sku":"6630-590","price":2301.68,"currency_code":"USD","in_stock":true},{"title":"3\/4 HP - 4 in Motor \/ 230V 1Ph 3-Wire \/ Switch - 23075V3-APS - 293 ft at 7 GPM","offer_id":46602927177903,"sku":"6630-644","price":2169.77,"currency_code":"USD","in_stock":true},{"title":"3\/4 HP - 4 in Motor \/ 230V 1Ph 3-Wire \/ Transducer - 23075V3-APT - 293 ft at 7 GPM","offer_id":46602927341743,"sku":"6630-638","price":2347.65,"currency_code":"USD","in_stock":true},{"title":"1 HP - 4 in Motor \/ 230V 1Ph 2-Wire \/ Switch - 23100V2-APS - 382 ft at 7 GPM","offer_id":46602926948527,"sku":"6630-608","price":2508.69,"currency_code":"USD","in_stock":true},{"title":"1 HP - 4 in Motor \/ 230V 1Ph 2-Wire \/ Transducer - 23100V2-APT - 382 ft at 7 GPM","offer_id":46602927079599,"sku":"6630-602","price":2686.57,"currency_code":"USD","in_stock":true},{"title":"1 HP - 4 in Motor \/ 230V 1Ph 3-Wire \/ Switch - 23100V3-APS - 382 ft at 7 GPM","offer_id":46602927210671,"sku":"6630-656","price":2367.11,"currency_code":"USD","in_stock":true},{"title":"1 HP - 4 in Motor \/ 230V 1Ph 3-Wire \/ Transducer - 23100V3-APT - 382 ft at 7 GPM","offer_id":46602927374511,"sku":"6630-650","price":2545.5,"currency_code":"USD","in_stock":true},{"title":"1 1\/2 HP - 4 in Motor \/ 230V 1Ph 2-Wire \/ Switch - 23150V2-APS - 483 ft at 7 GPM","offer_id":46602926981295,"sku":"6630-620","price":2864.44,"currency_code":"USD","in_stock":true},{"title":"1 1\/2 HP - 4 in Motor \/ 230V 1Ph 2-Wire \/ Transducer - 23150V2-APT - 483 ft at 7 GPM","offer_id":46602927112367,"sku":"6630-614","price":3044.36,"currency_code":"USD","in_stock":true},{"title":"1 1\/2 HP - 4 in Motor \/ 230V 1Ph 3-Wire \/ Switch - 23150V3-APS - 483 ft at 7 GPM","offer_id":46602927243439,"sku":"6630-668","price":2681.97,"currency_code":"USD","in_stock":true},{"title":"1 1\/2 HP - 4 in Motor \/ 230V 1Ph 3-Wire \/ Transducer - 23150V3-APT - 483 ft at 7 GPM","offer_id":46602927407279,"sku":"6630-662","price":2860.35,"currency_code":"USD","in_stock":true},{"title":"1 1\/2 HP - 4 in Motor \/ 230V 3Ph \/ Transducer - 23150V3Z-APT - 483 ft at 7 GPM","offer_id":46602927472815,"sku":"6630-850","price":3119.49,"currency_code":"USD","in_stock":true},{"title":"2 HP - 4 in Motor \/ 230V 1Ph 3-Wire \/ Switch - 23200V3-APS - 620 ft at 7 GPM","offer_id":46602927276207,"sku":"6630-678","price":3083.71,"currency_code":"USD","in_stock":true},{"title":"2 HP - 4 in Motor \/ 230V 1Ph 3-Wire \/ Transducer - 23200V3-APT - 620 ft at 7 GPM","offer_id":46602927440047,"sku":"6630-673","price":3262.11,"currency_code":"USD","in_stock":true},{"title":"2 HP - 4 in Motor \/ 230V 3Ph \/ Transducer - 23200V3Z-APT - 620 ft at 7 GPM","offer_id":46602927505583,"sku":"6630-683","price":3480.35,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0264\/1913\/4527\/files\/AutoPac_012ba96d-b092-4150-b058-3e539d6fae2e.png?v=1772502599"},{"product_id":"baker-autopac-k-10-gpm-23000-series","title":"A.Y. McDonald AutoPAC K - 10 GPM 23000 Constant Pressure Pump","description":"\u003c!-- TABS --\u003e\n\u003ch5\u003eDescription\u003c\/h5\u003e\n\u003cdiv class=\"gs\"\u003e\n\u003cdiv class=\"gs-head\"\u003e\n\u003cdiv class=\"gs-eyebrow\"\u003eA.Y. McDonald · Constant Pressure Pump System\u003c\/div\u003e\n\u003cdiv class=\"gs-title\"\u003eAutoPAC K - 10 GPM, 23000 Series\u003c\/div\u003e\n\u003cdiv class=\"gs-sub\"\u003eBaker domestic stainless steel 4 in submersible pump, motor and AutoDRIVE constant pressure drive, 1\/2 to 5 HP, 22 builds.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"gs-badges\"\u003e\n\u003cdiv class=\"gs-badge\" style=\"background:#B3122A;color:#FFFFFF;border-color:#B3122A\"\u003e171-864 ft at 10 GPM\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003e1\/2-5 HP\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003e230V Single-Phase Supply\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003eAutoDRIVE Constant Pressure VFD\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003ePressure Switch or Transducer Control\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003e1331 ft Max Head (Shut-off)\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003e1 1\/4 in NPT Discharge\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003eNEMA 3R Drive Enclosure\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003e40-83 lb Weight\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background:#FFFFFF;border:1px solid #C7CBD1;border-top:3px solid #B3122A;padding:12px 16px 12px;margin:16px 0 4px;font-size:13.5px;line-height:1.55;color:#4A4A4F\"\u003e\n\u003cdiv style=\"font-family:Arial Black,Arial,sans-serif;font-size:11px;letter-spacing:1.2px;text-transform:uppercase;color:#B3122A;margin-bottom:8px\"\u003eWhat Ships and What It Needs to Run\u003c\/div\u003e\n\u003cp style=\"margin:0 0 6px\"\u003e\u003cstrong style=\"color:#B3122A\"\u003eIncluded:\u003c\/strong\u003e the pump end and Baker 4 in motor, assembled, with the AutoDRIVE constant pressure drive matched to the motor, and the pressure switch (APS models) or pressure transducer with 10 ft wire (APT models). The drive model for each build is in the Models table.\u003c\/p\u003e\n\u003cp style=\"margin:0 0 6px\"\u003e\u003cstrong style=\"color:#B3122A\"\u003ePower:\u003c\/strong\u003e 230V single-phase supply from a circuit breaker for every build; the three-phase builds take single-phase power and the drive makes three-phase for the motor. Breaker sizes are under Before You Buy.\u003c\/p\u003e\n\u003cp style=\"margin:0\"\u003e\u003cstrong style=\"color:#B3122A\"\u003eSized at install:\u003c\/strong\u003e drop cable, splice kit and the pressure relief valve shown in the manufacturer’s installation diagram.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eOverview\u003c\/div\u003e\n\u003cdiv class=\"gs-lead\"\u003e\n\u003cp\u003eThe AutoPAC is Baker’s constant pressure well package: a 23000 Series 4 in submersible pump, a Baker motor of the same horsepower, and the AutoDRIVE variable frequency drive. The drive holds a set pressure by changing the pump speed, which allows a smaller pressure tank and a quick, simple installation; setup takes 5 steps or less on the drive’s backlit display.\u003c\/p\u003e\n\u003cp\u003eThis listing is the \u003cstrong\u003eK - 10 GPM\u003c\/strong\u003e class: 1\/2 to 5 HP, with pressure switch and transducer control. The AutoDRIVE is American made and housed in a NEMA 3R steel enclosure rated for outdoor use.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background:#E1E3E6;border-left:3px solid #B8BDC4;padding:8px 14px;font-size:11.5px;color:#4A4A4F;margin-top:14px;line-height:1.5\"\u003eGenuine A.Y. McDonald equipment, factory-new in original packaging — sold and supported by Watermain Supply, an independent industrial supplier. Watermain Supply is an Authorized Stocking A.Y. McDonald and Baker Water Systems Distributor.\u003c\/div\u003e\n\u003cdiv style=\"background:#fff;border-left:5px solid #B3122A;padding:15px 18px;margin-top:12px\"\u003e\n\u003cdiv style=\"font-family:Arial Black,Arial,sans-serif;font-size:15px;color:#B3122A;text-transform:uppercase;letter-spacing:1px;margin-bottom:6px\"\u003eA.Y. McDonald Warranty\u003c\/div\u003e\n\u003cp style=\"margin:0;font-size:13.5px;color:#4A4A4F;line-height:1.55\"\u003ePump and motor: covered for \u003cstrong\u003e5 years from the date of manufacture in potable water applications\u003c\/strong\u003e, and 3 years from the date of manufacture in other applications, under A.Y. McDonald’s published terms for Baker submersible motors and assembled submersible pumps. The AutoDRIVE and pressure control fall under A.Y. McDonald’s standard limited warranty: 2 years from the date of manufacture or 1 year from installation, whichever comes first.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eRoom to Grow\u003c\/div\u003e\n\u003cdiv class=\"gs-lead\"\u003e\n\u003cp\u003eOne pump and one drive per well. Need more head later? Step up in horsepower within the K - 10 GPM class; the drive model changes with the motor (see the Models table). Need more flow? Move to a higher flow class of the AutoPAC 23000 Series; every class uses the same 1 1\/4 in NPT discharge.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eModels \u0026amp; Ratings (60 Hz)\u003c\/div\u003e\n\u003cdiv class=\"gs-lead\"\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003cth\u003ePart No.\u003c\/th\u003e\n\u003cth\u003eHP\u003c\/th\u003e\n\u003cth\u003eMotor\u003c\/th\u003e\n\u003cth\u003eControl\u003c\/th\u003e\n\u003cth\u003eAutoDRIVE\u003c\/th\u003e\n\u003cth\u003eHead at 10 GPM\u003c\/th\u003e\n\u003cth\u003eShut-off Head\u003c\/th\u003e\n\u003cth\u003eWeight\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e23050K2-APS\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6630-585\u003c\/td\u003e\n\u003ctd\u003e1\/2\u003c\/td\u003e\n\u003ctd\u003e230V 1Ph 2-Wire\u003c\/td\u003e\n\u003ctd\u003ePressure Switch\u003c\/td\u003e\n\u003ctd\u003eSD1-2HP2PS\u003c\/td\u003e\n\u003ctd\u003e171 ft\u003c\/td\u003e\n\u003ctd\u003e259 ft\u003c\/td\u003e\n\u003ctd\u003e42 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e23050K2-APT\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6630-579\u003c\/td\u003e\n\u003ctd\u003e1\/2\u003c\/td\u003e\n\u003ctd\u003e230V 1Ph 2-Wire\u003c\/td\u003e\n\u003ctd\u003eTransducer\u003c\/td\u003e\n\u003ctd\u003eSD1-2HP2\u003c\/td\u003e\n\u003ctd\u003e171 ft\u003c\/td\u003e\n\u003ctd\u003e259 ft\u003c\/td\u003e\n\u003ctd\u003e42 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e23050K3-APS\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6630-633\u003c\/td\u003e\n\u003ctd\u003e1\/2\u003c\/td\u003e\n\u003ctd\u003e230V 1Ph 3-Wire\u003c\/td\u003e\n\u003ctd\u003ePressure Switch\u003c\/td\u003e\n\u003ctd\u003eSD1-2HP2PS\u003c\/td\u003e\n\u003ctd\u003e171 ft\u003c\/td\u003e\n\u003ctd\u003e259 ft\u003c\/td\u003e\n\u003ctd\u003e40 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e23050K3-APT\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6630-627\u003c\/td\u003e\n\u003ctd\u003e1\/2\u003c\/td\u003e\n\u003ctd\u003e230V 1Ph 3-Wire\u003c\/td\u003e\n\u003ctd\u003eTransducer\u003c\/td\u003e\n\u003ctd\u003eSD1-2HP2\u003c\/td\u003e\n\u003ctd\u003e171 ft\u003c\/td\u003e\n\u003ctd\u003e259 ft\u003c\/td\u003e\n\u003ctd\u003e40 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e23075K2-APS\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6630-597\u003c\/td\u003e\n\u003ctd\u003e3\/4\u003c\/td\u003e\n\u003ctd\u003e230V 1Ph 2-Wire\u003c\/td\u003e\n\u003ctd\u003ePressure Switch\u003c\/td\u003e\n\u003ctd\u003eSD1-2HP2PS\u003c\/td\u003e\n\u003ctd\u003e221 ft\u003c\/td\u003e\n\u003ctd\u003e333 ft\u003c\/td\u003e\n\u003ctd\u003e49 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e23075K2-APT\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6630-591\u003c\/td\u003e\n\u003ctd\u003e3\/4\u003c\/td\u003e\n\u003ctd\u003e230V 1Ph 2-Wire\u003c\/td\u003e\n\u003ctd\u003eTransducer\u003c\/td\u003e\n\u003ctd\u003eSD1-2HP2\u003c\/td\u003e\n\u003ctd\u003e221 ft\u003c\/td\u003e\n\u003ctd\u003e333 ft\u003c\/td\u003e\n\u003ctd\u003e45 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e23075K3-APS\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6630-645\u003c\/td\u003e\n\u003ctd\u003e3\/4\u003c\/td\u003e\n\u003ctd\u003e230V 1Ph 3-Wire\u003c\/td\u003e\n\u003ctd\u003ePressure Switch\u003c\/td\u003e\n\u003ctd\u003eSD1-2HP2PS\u003c\/td\u003e\n\u003ctd\u003e221 ft\u003c\/td\u003e\n\u003ctd\u003e333 ft\u003c\/td\u003e\n\u003ctd\u003e42 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e23075K3-APT\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6630-639\u003c\/td\u003e\n\u003ctd\u003e3\/4\u003c\/td\u003e\n\u003ctd\u003e230V 1Ph 3-Wire\u003c\/td\u003e\n\u003ctd\u003eTransducer\u003c\/td\u003e\n\u003ctd\u003eSD1-2HP2\u003c\/td\u003e\n\u003ctd\u003e221 ft\u003c\/td\u003e\n\u003ctd\u003e333 ft\u003c\/td\u003e\n\u003ctd\u003e42 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e23100K2-APS\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6630-609\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003ctd\u003e230V 1Ph 2-Wire\u003c\/td\u003e\n\u003ctd\u003ePressure Switch\u003c\/td\u003e\n\u003ctd\u003eSD1-2HP2PS\u003c\/td\u003e\n\u003ctd\u003e307 ft\u003c\/td\u003e\n\u003ctd\u003e448 ft\u003c\/td\u003e\n\u003ctd\u003e50 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e23100K2-APT\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6630-603\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003ctd\u003e230V 1Ph 2-Wire\u003c\/td\u003e\n\u003ctd\u003eTransducer\u003c\/td\u003e\n\u003ctd\u003eSD1-2HP2\u003c\/td\u003e\n\u003ctd\u003e307 ft\u003c\/td\u003e\n\u003ctd\u003e448 ft\u003c\/td\u003e\n\u003ctd\u003e50 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e23100K3-APS\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6630-657\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003ctd\u003e230V 1Ph 3-Wire\u003c\/td\u003e\n\u003ctd\u003ePressure Switch\u003c\/td\u003e\n\u003ctd\u003eSD1-2HP2PS\u003c\/td\u003e\n\u003ctd\u003e307 ft\u003c\/td\u003e\n\u003ctd\u003e448 ft\u003c\/td\u003e\n\u003ctd\u003e49 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e23100K3-APT\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6630-651\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003ctd\u003e230V 1Ph 3-Wire\u003c\/td\u003e\n\u003ctd\u003eTransducer\u003c\/td\u003e\n\u003ctd\u003eSD1-2HP2\u003c\/td\u003e\n\u003ctd\u003e307 ft\u003c\/td\u003e\n\u003ctd\u003e448 ft\u003c\/td\u003e\n\u003ctd\u003e49 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e23150K2-APS\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6630-621\u003c\/td\u003e\n\u003ctd\u003e1 1\/2\u003c\/td\u003e\n\u003ctd\u003e230V 1Ph 2-Wire\u003c\/td\u003e\n\u003ctd\u003ePressure Switch\u003c\/td\u003e\n\u003ctd\u003eSD1-2HP2PS\u003c\/td\u003e\n\u003ctd\u003e392 ft\u003c\/td\u003e\n\u003ctd\u003e591 ft\u003c\/td\u003e\n\u003ctd\u003e58 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e23150K2-APT\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6630-615\u003c\/td\u003e\n\u003ctd\u003e1 1\/2\u003c\/td\u003e\n\u003ctd\u003e230V 1Ph 2-Wire\u003c\/td\u003e\n\u003ctd\u003eTransducer\u003c\/td\u003e\n\u003ctd\u003eSD1-2HP2\u003c\/td\u003e\n\u003ctd\u003e392 ft\u003c\/td\u003e\n\u003ctd\u003e591 ft\u003c\/td\u003e\n\u003ctd\u003e58 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e23150K3-APS\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6630-669\u003c\/td\u003e\n\u003ctd\u003e1 1\/2\u003c\/td\u003e\n\u003ctd\u003e230V 1Ph 3-Wire\u003c\/td\u003e\n\u003ctd\u003ePressure Switch\u003c\/td\u003e\n\u003ctd\u003eSD1-2HP2PS\u003c\/td\u003e\n\u003ctd\u003e392 ft\u003c\/td\u003e\n\u003ctd\u003e591 ft\u003c\/td\u003e\n\u003ctd\u003e57 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e23150K3-APT\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6630-663\u003c\/td\u003e\n\u003ctd\u003e1 1\/2\u003c\/td\u003e\n\u003ctd\u003e230V 1Ph 3-Wire\u003c\/td\u003e\n\u003ctd\u003eTransducer\u003c\/td\u003e\n\u003ctd\u003eSD1-2HP2\u003c\/td\u003e\n\u003ctd\u003e392 ft\u003c\/td\u003e\n\u003ctd\u003e591 ft\u003c\/td\u003e\n\u003ctd\u003e57 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e23150K3Z-APT\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6630-851\u003c\/td\u003e\n\u003ctd\u003e1 1\/2\u003c\/td\u003e\n\u003ctd\u003e230V 3Ph\u003c\/td\u003e\n\u003ctd\u003eTransducer\u003c\/td\u003e\n\u003ctd\u003eSD3-2HP2\u003c\/td\u003e\n\u003ctd\u003e392 ft\u003c\/td\u003e\n\u003ctd\u003e591 ft\u003c\/td\u003e\n\u003ctd\u003e50 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e23200K3-APS\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6630-679\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e230V 1Ph 3-Wire\u003c\/td\u003e\n\u003ctd\u003ePressure Switch\u003c\/td\u003e\n\u003ctd\u003eSD1-2HP2PS\u003c\/td\u003e\n\u003ctd\u003e486 ft\u003c\/td\u003e\n\u003ctd\u003e758 ft\u003c\/td\u003e\n\u003ctd\u003e59 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e23200K3-APT\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6630-674\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e230V 1Ph 3-Wire\u003c\/td\u003e\n\u003ctd\u003eTransducer\u003c\/td\u003e\n\u003ctd\u003eSD1-2HP2\u003c\/td\u003e\n\u003ctd\u003e486 ft\u003c\/td\u003e\n\u003ctd\u003e758 ft\u003c\/td\u003e\n\u003ctd\u003e59 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e23200K3Z-APT\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6630-684\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e230V 3Ph\u003c\/td\u003e\n\u003ctd\u003eTransducer\u003c\/td\u003e\n\u003ctd\u003eSD3-2HP2\u003c\/td\u003e\n\u003ctd\u003e486 ft\u003c\/td\u003e\n\u003ctd\u003e758 ft\u003c\/td\u003e\n\u003ctd\u003e57 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e23300K3Z-APT\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6630-688\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003ctd\u003e230V 3Ph\u003c\/td\u003e\n\u003ctd\u003eTransducer\u003c\/td\u003e\n\u003ctd\u003eSD3-3HP2\u003c\/td\u003e\n\u003ctd\u003e667 ft\u003c\/td\u003e\n\u003ctd\u003e1042 ft\u003c\/td\u003e\n\u003ctd\u003e70 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e23500K3Z-APT\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6630-692\u003c\/td\u003e\n\u003ctd\u003e5\u003c\/td\u003e\n\u003ctd\u003e230V 3Ph\u003c\/td\u003e\n\u003ctd\u003eTransducer\u003c\/td\u003e\n\u003ctd\u003eSD3-5HP2\u003c\/td\u003e\n\u003ctd\u003e864 ft\u003c\/td\u003e\n\u003ctd\u003e1331 ft\u003c\/td\u003e\n\u003ctd\u003e83 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"font-size:12.5px;color:#9B9EA3;margin-top:8px;line-height:1.55\"\u003eHead at 10 GPM is read from the published AutoPAC curve (Pumps by Baker catalog (Sept 2025, rev 3\/26), p. 149), digitized and rounded down. Shut-off head as printed. Drive per the compatibility table on p. 141 (1 1\/2 HP three-phase builds use the SD3-2HP2). Sources: Pumps by Baker catalog (Sept 2025, rev 3\/26), pp. 141-143 and 149; Baker Pumps and Accessories price list, effective 7\/1\/2026.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eShared Specifications\u003c\/div\u003e\n\u003cdiv class=\"gs-lead\"\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eIncluded\u003c\/td\u003e\n\u003ctd\u003ePump end, Baker 4 in motor, AutoDRIVE drive, and pressure switch or transducer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDischarge\u003c\/td\u003e\n\u003ctd\u003e1 1\/4 in NPT (female)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCheck valve\u003c\/td\u003e\n\u003ctd\u003eBuilt in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply\u003c\/td\u003e\n\u003ctd\u003e230V single-phase, 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor\u003c\/td\u003e\n\u003ctd\u003eBaker 4 in submersible motor, matched to the pump end horsepower\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePump diameter\u003c\/td\u003e\n\u003ctd\u003e3 3\/4 in with cable guard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrive enclosure\u003c\/td\u003e\n\u003ctd\u003eNEMA Type 3R steel, 12.25 x 9.25 x 4.68 in, 13 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrive operating temperature\u003c\/td\u003e\n\u003ctd\u003e-4 to 122°F; SD3-5HP2 rated to 104°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrive efficiency\u003c\/td\u003e\n\u003ctd\u003e95%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApp connection\u003c\/td\u003e\n\u003ctd\u003eNone; set up on the drive display\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"font-size:12.5px;color:#9B9EA3;margin-top:8px;line-height:1.55\"\u003eSource: Pumps by Baker catalog (Sept 2025, rev 3\/26), pp. 131-133 and 141-143.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003ePerformance — Will It Do What You Need?\u003c\/div\u003e\n\u003cdiv class=\"gs-lead\"\u003e\n\u003cp\u003e\u003cstrong\u003eTotal head\u003c\/strong\u003e is everything the pump lifts against: the vertical lift from the pumping water level to the discharge, the pressure you set on the drive (2.31 ft for every PSI), and friction in the drop pipe. The drive slows the pump when demand falls, so the curve below is the most the pump delivers at full speed.\u003c\/p\u003e\n\u003cp style=\"margin-bottom:4px\"\u003e\u003cstrong\u003eTotal head in feet, by flow in GPM, at full speed\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eHP (stages)\u003c\/th\u003e\n\u003cth\u003e0\u003c\/th\u003e\n\u003cth\u003e2\u003c\/th\u003e\n\u003cth\u003e4\u003c\/th\u003e\n\u003cth\u003e6\u003c\/th\u003e\n\u003cth\u003e8\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003e10\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e12\u003c\/th\u003e\n\u003cth\u003e14\u003c\/th\u003e\n\u003cth\u003e16\u003c\/th\u003e\n\u003cth\u003e18\u003c\/th\u003e\n\u003cth\u003e20\u003c\/th\u003e\n\u003cth\u003e21\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e1\/2 HP (7)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e257\u003c\/td\u003e\n\u003ctd\u003e247\u003c\/td\u003e\n\u003ctd\u003e233\u003c\/td\u003e\n\u003ctd\u003e217\u003c\/td\u003e\n\u003ctd\u003e197\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e171\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e143\u003c\/td\u003e\n\u003ctd\u003e115\u003c\/td\u003e\n\u003ctd\u003e87\u003c\/td\u003e\n\u003ctd\u003e57\u003c\/td\u003e\n\u003ctd\u003e26\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e3\/4 HP (9)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e343\u003c\/td\u003e\n\u003ctd\u003e329\u003c\/td\u003e\n\u003ctd\u003e304\u003c\/td\u003e\n\u003ctd\u003e278\u003c\/td\u003e\n\u003ctd\u003e250\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e221\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e192\u003c\/td\u003e\n\u003ctd\u003e160\u003c\/td\u003e\n\u003ctd\u003e122\u003c\/td\u003e\n\u003ctd\u003e81\u003c\/td\u003e\n\u003ctd\u003e38\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e1 HP (12)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e441\u003c\/td\u003e\n\u003ctd\u003e419\u003c\/td\u003e\n\u003ctd\u003e394\u003c\/td\u003e\n\u003ctd\u003e367\u003c\/td\u003e\n\u003ctd\u003e339\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e307\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e268\u003c\/td\u003e\n\u003ctd\u003e222\u003c\/td\u003e\n\u003ctd\u003e167\u003c\/td\u003e\n\u003ctd\u003e111\u003c\/td\u003e\n\u003ctd\u003e50\u003c\/td\u003e\n\u003ctd\u003e15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e1 1\/2 HP (16)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e602\u003c\/td\u003e\n\u003ctd\u003e565\u003c\/td\u003e\n\u003ctd\u003e526\u003c\/td\u003e\n\u003ctd\u003e483\u003c\/td\u003e\n\u003ctd\u003e439\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e392\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e336\u003c\/td\u003e\n\u003ctd\u003e277\u003c\/td\u003e\n\u003ctd\u003e209\u003c\/td\u003e\n\u003ctd\u003e134\u003c\/td\u003e\n\u003ctd\u003e53\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e2 HP (20)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e762\u003c\/td\u003e\n\u003ctd\u003e728\u003c\/td\u003e\n\u003ctd\u003e672\u003c\/td\u003e\n\u003ctd\u003e614\u003c\/td\u003e\n\u003ctd\u003e553\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e486\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e414\u003c\/td\u003e\n\u003ctd\u003e335\u003c\/td\u003e\n\u003ctd\u003e257\u003c\/td\u003e\n\u003ctd\u003e167\u003c\/td\u003e\n\u003ctd\u003e48\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e3 HP (26)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1043\u003c\/td\u003e\n\u003ctd\u003e974\u003c\/td\u003e\n\u003ctd\u003e904\u003c\/td\u003e\n\u003ctd\u003e827\u003c\/td\u003e\n\u003ctd\u003e752\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e667\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e569\u003c\/td\u003e\n\u003ctd\u003e470\u003c\/td\u003e\n\u003ctd\u003e358\u003c\/td\u003e\n\u003ctd\u003e242\u003c\/td\u003e\n\u003ctd\u003e113\u003c\/td\u003e\n\u003ctd\u003e43\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e5 HP (33)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1335\u003c\/td\u003e\n\u003ctd\u003e1255\u003c\/td\u003e\n\u003ctd\u003e1166\u003c\/td\u003e\n\u003ctd\u003e1068\u003c\/td\u003e\n\u003ctd\u003e968\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e864\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e738\u003c\/td\u003e\n\u003ctd\u003e605\u003c\/td\u003e\n\u003ctd\u003e454\u003c\/td\u003e\n\u003ctd\u003e301\u003c\/td\u003e\n\u003ctd\u003e124\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"font-size:12.5px;color:#9B9EA3;margin-top:6px;line-height:1.55\"\u003eDigitized from the published AutoPAC curve in the Pumps by Baker catalog (Sept 2025, rev 3\/26), p. 149, and rounded down. Rated flow (10 GPM) in bold. Zero flow is the shut-off point, a ceiling rather than a working point; — marks flows past the end of that curve.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBest operating range:\u003c\/strong\u003e the published curve shades the most efficient operating range; the catalog prints no figures for it. The curve is in the image gallery.\u003c\/p\u003e\n\u003cdiv style=\"display:flex;flex-wrap:wrap;gap:10px;margin:22px 0 4px\"\u003e\n\u003ca href=\"\/pages\/submersible-well-pump-sizing-calculator\" style=\"flex:1 1 200px;text-align:center;display:block;background:#B3122A;color:#ffffff;font-family:Arial Black,Arial,sans-serif;font-size:12px;text-transform:uppercase;letter-spacing:1.2px;padding:11px 18px;text-decoration:none\"\u003eSubmersible Calculator\u003c\/a\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eBefore You Buy — The Limits That Decide the Fit\u003c\/div\u003e\n\u003cdiv class=\"gs-lead\"\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply\u003c\/td\u003e\n\u003ctd\u003e230V single-phase for every build, from a circuit breaker sized per the table below\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure transducer\u003c\/td\u003e\n\u003ctd\u003eMust be installed upright and vertical (manufacturer note)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrive location\u003c\/td\u003e\n\u003ctd\u003eNEMA 3R enclosure, outdoors or indoors; rated to 122°F (104°F for SD3-5HP2); derate above 5500 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor cooling\u003c\/td\u003e\n\u003ctd\u003e1.0 ft\/sec of water flow past the motor at 95°F; motor rated to 95°F water\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWell size\u003c\/td\u003e\n\u003ctd\u003e4 in casing and larger\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePairing\u003c\/td\u003e\n\u003ctd\u003eOne pump and one drive per well\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"margin:14px 0 4px\"\u003e\u003cstrong\u003eBreaker sizing by motor HP (manufacturer recommendation)\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSupply\u003c\/th\u003e\n\u003cth\u003eMotor HP\u003c\/th\u003e\n\u003cth\u003eInput Current\u003c\/th\u003e\n\u003cth\u003eFuse \/ Breaker\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e230V\u003c\/td\u003e\n\u003ctd\u003e1\/2\u003c\/td\u003e\n\u003ctd\u003e6 A\u003c\/td\u003e\n\u003ctd\u003e10 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e230V\u003c\/td\u003e\n\u003ctd\u003e3\/4\u003c\/td\u003e\n\u003ctd\u003e9 A\u003c\/td\u003e\n\u003ctd\u003e15 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e230V\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003ctd\u003e14 A\u003c\/td\u003e\n\u003ctd\u003e20 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e230V\u003c\/td\u003e\n\u003ctd\u003e1 1\/2\u003c\/td\u003e\n\u003ctd\u003e18 A\u003c\/td\u003e\n\u003ctd\u003e25 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e230V\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e28 A\u003c\/td\u003e\n\u003ctd\u003e35 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e230V\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e20 A\u003c\/td\u003e\n\u003ctd\u003e25 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e230V\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003ctd\u003e30 A\u003c\/td\u003e\n\u003ctd\u003e40 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e230V\u003c\/td\u003e\n\u003ctd\u003e5\u003c\/td\u003e\n\u003ctd\u003e42 A\u003c\/td\u003e\n\u003ctd\u003e55 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"font-size:12.5px;color:#9B9EA3;margin-top:8px;line-height:1.55\"\u003eSource: Pumps by Baker catalog (Sept 2025, rev 3\/26), p. 131.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eMaterials of Construction (Pump)\u003c\/div\u003e\n\u003cdiv class=\"gs-lead\"\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eDischarge\u003c\/td\u003e\n\u003ctd\u003e300 series stainless steel, easy-wrench design with built-in safety eye; threads into the shell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCheck valve\u003c\/td\u003e\n\u003ctd\u003eBaker Diamond Design, easy-out for service\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDischarge bearing\u003c\/td\u003e\n\u003ctd\u003eRubber around the stainless steel shaft; self-lubricating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiffusers\u003c\/td\u003e\n\u003ctd\u003ePolycarbonate, corrosion and abrasion resistant, built for sand handling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eImpellers\u003c\/td\u003e\n\u003ctd\u003eGlass bead acetal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShaft\u003c\/td\u003e\n\u003ctd\u003e7\/16 in 300 series stainless steel, hex drive, each one measured for straightness\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShell\u003c\/td\u003e\n\u003ctd\u003eHeavy stainless steel, threaded at both ends for field service\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable guard\u003c\/td\u003e\n\u003ctd\u003eStainless steel; angled top keeps the leads in place\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor bracket\u003c\/td\u003e\n\u003ctd\u003eStainless steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"font-size:12.5px;color:#9B9EA3;margin-top:8px;line-height:1.55\"\u003eSource: Pumps by Baker catalog (Sept 2025, rev 3\/26), pp. 51-52.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eService Parts\u003c\/div\u003e\n\u003cdiv class=\"gs-lead\"\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003ePart\u003c\/th\u003e\n\u003cth\u003ePart No.\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutoDRIVE pressure transducer with 10 ft wire\u003c\/td\u003e\n\u003ctd\u003e6619-028\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutoDRIVE pressure switch with wire\u003c\/td\u003e\n\u003ctd\u003e6619-029\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutoDRIVE keypad\u003c\/td\u003e\n\u003ctd\u003e6619-030\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"font-size:12.5px;color:#9B9EA3;margin-top:8px;line-height:1.55\"\u003eSource: Pumps by Baker catalog (Sept 2025, rev 3\/26), pp. 142-143.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"gs-contact\"\u003eFor engineering-led sizing and selection support or a factory submittal, email \u003ca href=\"mailto:sales@watermainsupply.com\"\u003esales@watermainsupply.com\u003c\/a\u003e or call \u003ca href=\"tel:18885104036\"\u003e1-888.510.4036\u003c\/a\u003e.\u003cbr\u003e© Watermain Supply — A division of E4 Industrial LLC\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch5\u003eData Sheet\u003c\/h5\u003e\n\u003cdiv class=\"gs\"\u003e\n\u003cdiv class=\"gs-dl\"\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0264\/1913\/4527\/files\/AutoPac_Guide.pdf?v=1772502299\" target=\"_blank\" rel=\"noopener\"\u003ePumps by Baker AutoPac Guide\u003c\/a\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch5\u003eVideos\u003c\/h5\u003e\n\u003cdiv class=\"gs\"\u003e\u003cdiv class=\"gs-sec\" style=\"margin-top:6px\"\u003e\n\u003cp style=\"font-size:13px;color:#9B9EA3\"\u003eProduct videos are being added to this listing. For a walkthrough in the meantime, email sales@watermainsupply.com.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003c!-- \/TABS --\u003e","brand":"A.Y. McDonald","offers":[{"title":"1\/2 HP - 4 in Motor \/ 230V 1Ph 2-Wire \/ Switch - 23050K2-APS - 171 ft at 10 GPM","offer_id":46602927538351,"sku":"6630-585","price":1894.8,"currency_code":"USD","in_stock":true},{"title":"1\/2 HP - 4 in Motor \/ 230V 1Ph 2-Wire \/ Transducer - 23050K2-APT - 171 ft at 10 GPM","offer_id":46602927669423,"sku":"6630-579","price":2073.68,"currency_code":"USD","in_stock":true},{"title":"1\/2 HP - 4 in Motor \/ 230V 1Ph 3-Wire \/ Switch - 23050K3-APS - 171 ft at 10 GPM","offer_id":46602927800495,"sku":"6630-633","price":1808.41,"currency_code":"USD","in_stock":true},{"title":"1\/2 HP - 4 in Motor \/ 230V 1Ph 3-Wire \/ Transducer - 23050K3-APT - 171 ft at 10 GPM","offer_id":46602927964335,"sku":"6630-627","price":1986.8,"currency_code":"USD","in_stock":true},{"title":"3\/4 HP - 4 in Motor \/ 230V 1Ph 2-Wire \/ Switch - 23075K2-APS - 221 ft at 10 GPM","offer_id":46602927571119,"sku":"6630-597","price":2127.35,"currency_code":"USD","in_stock":true},{"title":"3\/4 HP - 4 in Motor \/ 230V 1Ph 2-Wire \/ Transducer - 23075K2-APT - 221 ft at 10 GPM","offer_id":46602927702191,"sku":"6630-591","price":2305.74,"currency_code":"USD","in_stock":true},{"title":"3\/4 HP - 4 in Motor \/ 230V 1Ph 3-Wire \/ Switch - 23075K3-APS - 221 ft at 10 GPM","offer_id":46602927833263,"sku":"6630-645","price":2011.83,"currency_code":"USD","in_stock":true},{"title":"3\/4 HP - 4 in Motor \/ 230V 1Ph 3-Wire \/ Transducer - 23075K3-APT - 221 ft at 10 GPM","offer_id":46602927997103,"sku":"6630-639","price":2191.25,"currency_code":"USD","in_stock":true},{"title":"1 HP - 4 in Motor \/ 230V 1Ph 2-Wire \/ Switch - 23100K2-APS - 307 ft at 10 GPM","offer_id":46602927603887,"sku":"6630-609","price":2225.49,"currency_code":"USD","in_stock":true},{"title":"1 HP - 4 in Motor \/ 230V 1Ph 2-Wire \/ Transducer - 23100K2-APT - 307 ft at 10 GPM","offer_id":46602927734959,"sku":"6630-603","price":2403.37,"currency_code":"USD","in_stock":true},{"title":"1 HP - 4 in Motor \/ 230V 1Ph 3-Wire \/ Switch - 23100K3-APS - 307 ft at 10 GPM","offer_id":46602927866031,"sku":"6630-657","price":2083.4,"currency_code":"USD","in_stock":true},{"title":"1 HP - 4 in Motor \/ 230V 1Ph 3-Wire \/ Transducer - 23100K3-APT - 307 ft at 10 GPM","offer_id":46602928029871,"sku":"6630-651","price":2262.29,"currency_code":"USD","in_stock":true},{"title":"1 1\/2 HP - 4 in Motor \/ 230V 1Ph 2-Wire \/ Switch - 23150K2-APS - 392 ft at 10 GPM","offer_id":46602927636655,"sku":"6630-621","price":2742.8,"currency_code":"USD","in_stock":true},{"title":"1 1\/2 HP - 4 in Motor \/ 230V 1Ph 2-Wire \/ Transducer - 23150K2-APT - 392 ft at 10 GPM","offer_id":46602927767727,"sku":"6630-615","price":2921.68,"currency_code":"USD","in_stock":true},{"title":"1 1\/2 HP - 4 in Motor \/ 230V 1Ph 3-Wire \/ Switch - 23150K3-APS - 392 ft at 10 GPM","offer_id":46602927898799,"sku":"6630-669","price":2559.8,"currency_code":"USD","in_stock":true},{"title":"1 1\/2 HP - 4 in Motor \/ 230V 1Ph 3-Wire \/ Transducer - 23150K3-APT - 392 ft at 10 GPM","offer_id":46602928062639,"sku":"6630-663","price":2738.71,"currency_code":"USD","in_stock":true},{"title":"1 1\/2 HP - 4 in Motor \/ 230V 3Ph \/ Transducer - 23150K3Z-APT - 392 ft at 10 GPM","offer_id":46602928128175,"sku":"6630-851","price":2959.98,"currency_code":"USD","in_stock":true},{"title":"2 HP - 4 in Motor \/ 230V 1Ph 3-Wire \/ Switch - 23200K3-APS - 486 ft at 10 GPM","offer_id":46602927931567,"sku":"6630-679","price":2929.86,"currency_code":"USD","in_stock":true},{"title":"2 HP - 4 in Motor \/ 230V 1Ph 3-Wire \/ Transducer - 23200K3-APT - 486 ft at 10 GPM","offer_id":46602928095407,"sku":"6630-674","price":3108.77,"currency_code":"USD","in_stock":true},{"title":"2 HP - 4 in Motor \/ 230V 3Ph \/ Transducer - 23200K3Z-APT - 486 ft at 10 GPM","offer_id":46602928160943,"sku":"6630-684","price":3326.5,"currency_code":"USD","in_stock":true},{"title":"3 HP - 4 in Motor \/ 230V 3Ph \/ Transducer - 23300K3Z-APT - 667 ft at 10 GPM","offer_id":46602928193711,"sku":"6630-688","price":4173.44,"currency_code":"USD","in_stock":true},{"title":"5 HP - 4 in Motor \/ 230V 3Ph \/ Transducer - 23500K3Z-APT - 864 ft at 10 GPM","offer_id":46602928226479,"sku":"6630-692","price":5797.89,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0264\/1913\/4527\/files\/AutoPac_ae64625d-1bd6-47ca-ab28-28f27bf5f568.png?v=1772502600"},{"product_id":"baker-autopac-l-15-gpm-23000-series","title":"A.Y. McDonald AutoPAC L - 15 GPM 23000 Constant Pressure Pump","description":"\u003c!-- TABS --\u003e\n\u003ch5\u003eDescription\u003c\/h5\u003e\n\u003cdiv class=\"gs\"\u003e\n\u003cdiv class=\"gs-head\"\u003e\n\u003cdiv class=\"gs-eyebrow\"\u003eA.Y. McDonald · Constant Pressure Pump System\u003c\/div\u003e\n\u003cdiv class=\"gs-title\"\u003eAutoPAC L - 15 GPM, 23000 Series\u003c\/div\u003e\n\u003cdiv class=\"gs-sub\"\u003eBaker domestic stainless steel 4 in submersible pump, motor and AutoDRIVE constant pressure drive, 1\/2 to 5 HP, 23 builds.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"gs-badges\"\u003e\n\u003cdiv class=\"gs-badge\" style=\"background:#B3122A;color:#FFFFFF;border-color:#B3122A\"\u003e121-771 ft at 15 GPM\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003e1\/2-5 HP\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003e230V Single-Phase Supply\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003eAutoDRIVE Constant Pressure VFD\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003ePressure Switch or Transducer Control\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003e1051 ft Max Head (Shut-off)\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003e1 1\/4 in NPT Discharge\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003eNEMA 3R Drive Enclosure\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003e40-85 lb Weight\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background:#FFFFFF;border:1px solid #C7CBD1;border-top:3px solid #B3122A;padding:12px 16px 12px;margin:16px 0 4px;font-size:13.5px;line-height:1.55;color:#4A4A4F\"\u003e\n\u003cdiv style=\"font-family:Arial Black,Arial,sans-serif;font-size:11px;letter-spacing:1.2px;text-transform:uppercase;color:#B3122A;margin-bottom:8px\"\u003eWhat Ships and What It Needs to Run\u003c\/div\u003e\n\u003cp style=\"margin:0 0 6px\"\u003e\u003cstrong style=\"color:#B3122A\"\u003eIncluded:\u003c\/strong\u003e the pump end and Baker 4 in motor, assembled, with the AutoDRIVE constant pressure drive matched to the motor, and the pressure switch (APS models) or pressure transducer with 10 ft wire (APT models). The drive model for each build is in the Models table.\u003c\/p\u003e\n\u003cp style=\"margin:0 0 6px\"\u003e\u003cstrong style=\"color:#B3122A\"\u003ePower:\u003c\/strong\u003e 230V single-phase supply from a circuit breaker for every build; the three-phase builds take single-phase power and the drive makes three-phase for the motor. Breaker sizes are under Before You Buy.\u003c\/p\u003e\n\u003cp style=\"margin:0\"\u003e\u003cstrong style=\"color:#B3122A\"\u003eSized at install:\u003c\/strong\u003e drop cable, splice kit and the pressure relief valve shown in the manufacturer’s installation diagram.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eOverview\u003c\/div\u003e\n\u003cdiv class=\"gs-lead\"\u003e\n\u003cp\u003eThe AutoPAC is Baker’s constant pressure well package: a 23000 Series 4 in submersible pump, a Baker motor of the same horsepower, and the AutoDRIVE variable frequency drive. The drive holds a set pressure by changing the pump speed, which allows a smaller pressure tank and a quick, simple installation; setup takes 5 steps or less on the drive’s backlit display.\u003c\/p\u003e\n\u003cp\u003eThis listing is the \u003cstrong\u003eL - 15 GPM\u003c\/strong\u003e class: 1\/2 to 5 HP, with pressure switch and transducer control. The AutoDRIVE is American made and housed in a NEMA 3R steel enclosure rated for outdoor use.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background:#E1E3E6;border-left:3px solid #B8BDC4;padding:8px 14px;font-size:11.5px;color:#4A4A4F;margin-top:14px;line-height:1.5\"\u003eGenuine A.Y. McDonald equipment, factory-new in original packaging — sold and supported by Watermain Supply, an independent industrial supplier. Watermain Supply is an Authorized Stocking A.Y. McDonald and Baker Water Systems Distributor.\u003c\/div\u003e\n\u003cdiv style=\"background:#fff;border-left:5px solid #B3122A;padding:15px 18px;margin-top:12px\"\u003e\n\u003cdiv style=\"font-family:Arial Black,Arial,sans-serif;font-size:15px;color:#B3122A;text-transform:uppercase;letter-spacing:1px;margin-bottom:6px\"\u003eA.Y. McDonald Warranty\u003c\/div\u003e\n\u003cp style=\"margin:0;font-size:13.5px;color:#4A4A4F;line-height:1.55\"\u003ePump and motor: covered for \u003cstrong\u003e5 years from the date of manufacture in potable water applications\u003c\/strong\u003e, and 3 years from the date of manufacture in other applications, under A.Y. McDonald’s published terms for Baker submersible motors and assembled submersible pumps. The AutoDRIVE and pressure control fall under A.Y. McDonald’s standard limited warranty: 2 years from the date of manufacture or 1 year from installation, whichever comes first.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eRoom to Grow\u003c\/div\u003e\n\u003cdiv class=\"gs-lead\"\u003e\n\u003cp\u003eOne pump and one drive per well. Need more head later? Step up in horsepower within the L - 15 GPM class; the drive model changes with the motor (see the Models table). Need more flow? Move to a higher flow class of the AutoPAC 23000 Series; every class uses the same 1 1\/4 in NPT discharge.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eModels \u0026amp; Ratings (60 Hz)\u003c\/div\u003e\n\u003cdiv class=\"gs-lead\"\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003cth\u003ePart No.\u003c\/th\u003e\n\u003cth\u003eHP\u003c\/th\u003e\n\u003cth\u003eMotor\u003c\/th\u003e\n\u003cth\u003eControl\u003c\/th\u003e\n\u003cth\u003eAutoDRIVE\u003c\/th\u003e\n\u003cth\u003eHead at 15 GPM\u003c\/th\u003e\n\u003cth\u003eShut-off Head\u003c\/th\u003e\n\u003cth\u003eWeight\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e23050L2-APS\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6630-586\u003c\/td\u003e\n\u003ctd\u003e1\/2\u003c\/td\u003e\n\u003ctd\u003e230V 1Ph 2-Wire\u003c\/td\u003e\n\u003ctd\u003ePressure Switch\u003c\/td\u003e\n\u003ctd\u003eSD1-2HP2PS\u003c\/td\u003e\n\u003ctd\u003e121 ft\u003c\/td\u003e\n\u003ctd\u003e173 ft\u003c\/td\u003e\n\u003ctd\u003e42 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e23050L2-APT\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6630-580\u003c\/td\u003e\n\u003ctd\u003e1\/2\u003c\/td\u003e\n\u003ctd\u003e230V 1Ph 2-Wire\u003c\/td\u003e\n\u003ctd\u003eTransducer\u003c\/td\u003e\n\u003ctd\u003eSD1-2HP2\u003c\/td\u003e\n\u003ctd\u003e121 ft\u003c\/td\u003e\n\u003ctd\u003e173 ft\u003c\/td\u003e\n\u003ctd\u003e42 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e23050L3-APS\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6630-634\u003c\/td\u003e\n\u003ctd\u003e1\/2\u003c\/td\u003e\n\u003ctd\u003e230V 1Ph 3-Wire\u003c\/td\u003e\n\u003ctd\u003ePressure Switch\u003c\/td\u003e\n\u003ctd\u003eSD1-2HP2PS\u003c\/td\u003e\n\u003ctd\u003e121 ft\u003c\/td\u003e\n\u003ctd\u003e173 ft\u003c\/td\u003e\n\u003ctd\u003e40 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e23050L3-APT\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6630-628\u003c\/td\u003e\n\u003ctd\u003e1\/2\u003c\/td\u003e\n\u003ctd\u003e230V 1Ph 3-Wire\u003c\/td\u003e\n\u003ctd\u003eTransducer\u003c\/td\u003e\n\u003ctd\u003eSD1-2HP2\u003c\/td\u003e\n\u003ctd\u003e121 ft\u003c\/td\u003e\n\u003ctd\u003e173 ft\u003c\/td\u003e\n\u003ctd\u003e40 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e23075L2-APS\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6630-598\u003c\/td\u003e\n\u003ctd\u003e3\/4\u003c\/td\u003e\n\u003ctd\u003e230V 1Ph 2-Wire\u003c\/td\u003e\n\u003ctd\u003ePressure Switch\u003c\/td\u003e\n\u003ctd\u003eSD1-2HP2PS\u003c\/td\u003e\n\u003ctd\u003e168 ft\u003c\/td\u003e\n\u003ctd\u003e233 ft\u003c\/td\u003e\n\u003ctd\u003e45 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e23075L2-APT\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6630-592\u003c\/td\u003e\n\u003ctd\u003e3\/4\u003c\/td\u003e\n\u003ctd\u003e230V 1Ph 2-Wire\u003c\/td\u003e\n\u003ctd\u003eTransducer\u003c\/td\u003e\n\u003ctd\u003eSD1-2HP2\u003c\/td\u003e\n\u003ctd\u003e168 ft\u003c\/td\u003e\n\u003ctd\u003e233 ft\u003c\/td\u003e\n\u003ctd\u003e45 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e23075L3-APS\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6630-646\u003c\/td\u003e\n\u003ctd\u003e3\/4\u003c\/td\u003e\n\u003ctd\u003e230V 1Ph 3-Wire\u003c\/td\u003e\n\u003ctd\u003ePressure Switch\u003c\/td\u003e\n\u003ctd\u003eSD1-2HP2PS\u003c\/td\u003e\n\u003ctd\u003e168 ft\u003c\/td\u003e\n\u003ctd\u003e233 ft\u003c\/td\u003e\n\u003ctd\u003e42 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e23075L3-APT\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6630-640\u003c\/td\u003e\n\u003ctd\u003e3\/4\u003c\/td\u003e\n\u003ctd\u003e230V 1Ph 3-Wire\u003c\/td\u003e\n\u003ctd\u003eTransducer\u003c\/td\u003e\n\u003ctd\u003eSD1-2HP2\u003c\/td\u003e\n\u003ctd\u003e168 ft\u003c\/td\u003e\n\u003ctd\u003e233 ft\u003c\/td\u003e\n\u003ctd\u003e42 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e23100L2-APS\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6630-610\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003ctd\u003e230V 1Ph 2-Wire\u003c\/td\u003e\n\u003ctd\u003ePressure Switch\u003c\/td\u003e\n\u003ctd\u003eSD1-2HP2PS\u003c\/td\u003e\n\u003ctd\u003e207 ft\u003c\/td\u003e\n\u003ctd\u003e291 ft\u003c\/td\u003e\n\u003ctd\u003e50 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e23100L2-APT\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6630-604\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003ctd\u003e230V 1Ph 2-Wire\u003c\/td\u003e\n\u003ctd\u003eTransducer\u003c\/td\u003e\n\u003ctd\u003eSD1-2HP2\u003c\/td\u003e\n\u003ctd\u003e207 ft\u003c\/td\u003e\n\u003ctd\u003e291 ft\u003c\/td\u003e\n\u003ctd\u003e50 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e23100L3-APS\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6630-658\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003ctd\u003e230V 1Ph 3-Wire\u003c\/td\u003e\n\u003ctd\u003ePressure Switch\u003c\/td\u003e\n\u003ctd\u003eSD1-2HP2PS\u003c\/td\u003e\n\u003ctd\u003e207 ft\u003c\/td\u003e\n\u003ctd\u003e291 ft\u003c\/td\u003e\n\u003ctd\u003e49 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e23100L3-APT\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6630-652\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003ctd\u003e230V 1Ph 3-Wire\u003c\/td\u003e\n\u003ctd\u003eTransducer\u003c\/td\u003e\n\u003ctd\u003eSD1-2HP2\u003c\/td\u003e\n\u003ctd\u003e207 ft\u003c\/td\u003e\n\u003ctd\u003e291 ft\u003c\/td\u003e\n\u003ctd\u003e49 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e23100L3Z-APT\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6630-885\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003ctd\u003e230V 3Ph\u003c\/td\u003e\n\u003ctd\u003eTransducer\u003c\/td\u003e\n\u003ctd\u003eSD3-2HP2\u003c\/td\u003e\n\u003ctd\u003e207 ft\u003c\/td\u003e\n\u003ctd\u003e291 ft\u003c\/td\u003e\n\u003ctd\u003e50 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e23150L2-APS\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6630-622\u003c\/td\u003e\n\u003ctd\u003e1 1\/2\u003c\/td\u003e\n\u003ctd\u003e230V 1Ph 2-Wire\u003c\/td\u003e\n\u003ctd\u003ePressure Switch\u003c\/td\u003e\n\u003ctd\u003eSD1-2HP2PS\u003c\/td\u003e\n\u003ctd\u003e277 ft\u003c\/td\u003e\n\u003ctd\u003e383 ft\u003c\/td\u003e\n\u003ctd\u003e57 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e23150L2-APT\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6630-616\u003c\/td\u003e\n\u003ctd\u003e1 1\/2\u003c\/td\u003e\n\u003ctd\u003e230V 1Ph 2-Wire\u003c\/td\u003e\n\u003ctd\u003eTransducer\u003c\/td\u003e\n\u003ctd\u003eSD1-2HP2\u003c\/td\u003e\n\u003ctd\u003e277 ft\u003c\/td\u003e\n\u003ctd\u003e383 ft\u003c\/td\u003e\n\u003ctd\u003e57 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e23150L3-APS\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6630-670\u003c\/td\u003e\n\u003ctd\u003e1 1\/2\u003c\/td\u003e\n\u003ctd\u003e230V 1Ph 3-Wire\u003c\/td\u003e\n\u003ctd\u003ePressure Switch\u003c\/td\u003e\n\u003ctd\u003eSD1-2HP2PS\u003c\/td\u003e\n\u003ctd\u003e277 ft\u003c\/td\u003e\n\u003ctd\u003e383 ft\u003c\/td\u003e\n\u003ctd\u003e56 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e23150L3-APT\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6630-664\u003c\/td\u003e\n\u003ctd\u003e1 1\/2\u003c\/td\u003e\n\u003ctd\u003e230V 1Ph 3-Wire\u003c\/td\u003e\n\u003ctd\u003eTransducer\u003c\/td\u003e\n\u003ctd\u003eSD1-2HP2\u003c\/td\u003e\n\u003ctd\u003e277 ft\u003c\/td\u003e\n\u003ctd\u003e383 ft\u003c\/td\u003e\n\u003ctd\u003e56 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e23150L3Z-APT\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6630-852\u003c\/td\u003e\n\u003ctd\u003e1 1\/2\u003c\/td\u003e\n\u003ctd\u003e230V 3Ph\u003c\/td\u003e\n\u003ctd\u003eTransducer\u003c\/td\u003e\n\u003ctd\u003eSD3-2HP2\u003c\/td\u003e\n\u003ctd\u003e277 ft\u003c\/td\u003e\n\u003ctd\u003e383 ft\u003c\/td\u003e\n\u003ctd\u003e49 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e23200L3-APS\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6630-680\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e230V 1Ph 3-Wire\u003c\/td\u003e\n\u003ctd\u003ePressure Switch\u003c\/td\u003e\n\u003ctd\u003eSD1-2HP2PS\u003c\/td\u003e\n\u003ctd\u003e363 ft\u003c\/td\u003e\n\u003ctd\u003e505 ft\u003c\/td\u003e\n\u003ctd\u003e58 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e23200L3-APT\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6630-675\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e230V 1Ph 3-Wire\u003c\/td\u003e\n\u003ctd\u003eTransducer\u003c\/td\u003e\n\u003ctd\u003eSD1-2HP2\u003c\/td\u003e\n\u003ctd\u003e363 ft\u003c\/td\u003e\n\u003ctd\u003e505 ft\u003c\/td\u003e\n\u003ctd\u003e58 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e23200L3Z-APT\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6630-685\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e230V 3Ph\u003c\/td\u003e\n\u003ctd\u003eTransducer\u003c\/td\u003e\n\u003ctd\u003eSD3-2HP2\u003c\/td\u003e\n\u003ctd\u003e363 ft\u003c\/td\u003e\n\u003ctd\u003e505 ft\u003c\/td\u003e\n\u003ctd\u003e56 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e23300L3Z-APT\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6630-689\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003ctd\u003e230V 3Ph\u003c\/td\u003e\n\u003ctd\u003eTransducer\u003c\/td\u003e\n\u003ctd\u003eSD3-3HP2\u003c\/td\u003e\n\u003ctd\u003e484 ft\u003c\/td\u003e\n\u003ctd\u003e660 ft\u003c\/td\u003e\n\u003ctd\u003e69 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e23500L3Z-APT\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6630-693\u003c\/td\u003e\n\u003ctd\u003e5\u003c\/td\u003e\n\u003ctd\u003e230V 3Ph\u003c\/td\u003e\n\u003ctd\u003eTransducer\u003c\/td\u003e\n\u003ctd\u003eSD3-5HP2\u003c\/td\u003e\n\u003ctd\u003e771 ft\u003c\/td\u003e\n\u003ctd\u003e1051 ft\u003c\/td\u003e\n\u003ctd\u003e85 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"font-size:12.5px;color:#9B9EA3;margin-top:8px;line-height:1.55\"\u003eHead at 15 GPM is read from the published AutoPAC curve (Pumps by Baker catalog (Sept 2025, rev 3\/26), p. 151), digitized and rounded down. Shut-off head as printed. Drive per the compatibility table on p. 141 (1 1\/2 HP three-phase builds use the SD3-2HP2). Sources: Pumps by Baker catalog (Sept 2025, rev 3\/26), pp. 141-143 and 151; Baker Pumps and Accessories price list, effective 7\/1\/2026.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eShared Specifications\u003c\/div\u003e\n\u003cdiv class=\"gs-lead\"\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eIncluded\u003c\/td\u003e\n\u003ctd\u003ePump end, Baker 4 in motor, AutoDRIVE drive, and pressure switch or transducer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDischarge\u003c\/td\u003e\n\u003ctd\u003e1 1\/4 in NPT (female)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCheck valve\u003c\/td\u003e\n\u003ctd\u003eBuilt in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply\u003c\/td\u003e\n\u003ctd\u003e230V single-phase, 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor\u003c\/td\u003e\n\u003ctd\u003eBaker 4 in submersible motor, matched to the pump end horsepower\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePump diameter\u003c\/td\u003e\n\u003ctd\u003e3 3\/4 in with cable guard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrive enclosure\u003c\/td\u003e\n\u003ctd\u003eNEMA Type 3R steel, 12.25 x 9.25 x 4.68 in, 13 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrive operating temperature\u003c\/td\u003e\n\u003ctd\u003e-4 to 122°F; SD3-5HP2 rated to 104°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrive efficiency\u003c\/td\u003e\n\u003ctd\u003e95%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApp connection\u003c\/td\u003e\n\u003ctd\u003eNone; set up on the drive display\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"font-size:12.5px;color:#9B9EA3;margin-top:8px;line-height:1.55\"\u003eSource: Pumps by Baker catalog (Sept 2025, rev 3\/26), pp. 131-133 and 141-143.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003ePerformance — Will It Do What You Need?\u003c\/div\u003e\n\u003cdiv class=\"gs-lead\"\u003e\n\u003cp\u003e\u003cstrong\u003eTotal head\u003c\/strong\u003e is everything the pump lifts against: the vertical lift from the pumping water level to the discharge, the pressure you set on the drive (2.31 ft for every PSI), and friction in the drop pipe. The drive slows the pump when demand falls, so the curve below is the most the pump delivers at full speed.\u003c\/p\u003e\n\u003cp style=\"margin-bottom:4px\"\u003e\u003cstrong\u003eTotal head in feet, by flow in GPM, at full speed\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eHP (stages)\u003c\/th\u003e\n\u003cth\u003e0\u003c\/th\u003e\n\u003cth\u003e5\u003c\/th\u003e\n\u003cth\u003e10\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003e15\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e20\u003c\/th\u003e\n\u003cth\u003e25\u003c\/th\u003e\n\u003cth\u003e30\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e1\/2 HP (6)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e184\u003c\/td\u003e\n\u003ctd\u003e166\u003c\/td\u003e\n\u003ctd\u003e143\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e121\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e94\u003c\/td\u003e\n\u003ctd\u003e52\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e3\/4 HP (8)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e235\u003c\/td\u003e\n\u003ctd\u003e220\u003c\/td\u003e\n\u003ctd\u003e199\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e168\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e130\u003c\/td\u003e\n\u003ctd\u003e69\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e1 HP (10)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e296\u003c\/td\u003e\n\u003ctd\u003e280\u003c\/td\u003e\n\u003ctd\u003e246\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e207\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e162\u003c\/td\u003e\n\u003ctd\u003e89\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e1 1\/2 HP (13)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e381\u003c\/td\u003e\n\u003ctd\u003e362\u003c\/td\u003e\n\u003ctd\u003e325\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e277\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e210\u003c\/td\u003e\n\u003ctd\u003e120\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e2 HP (17)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e501\u003c\/td\u003e\n\u003ctd\u003e475\u003c\/td\u003e\n\u003ctd\u003e429\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e363\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e271\u003c\/td\u003e\n\u003ctd\u003e148\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e3 HP (23)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e663\u003c\/td\u003e\n\u003ctd\u003e620\u003c\/td\u003e\n\u003ctd\u003e562\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e484\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e364\u003c\/td\u003e\n\u003ctd\u003e223\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e5 HP (35)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1051\u003c\/td\u003e\n\u003ctd\u003e984\u003c\/td\u003e\n\u003ctd\u003e897\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e771\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e574\u003c\/td\u003e\n\u003ctd\u003e329\u003c\/td\u003e\n\u003ctd\u003e35\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"font-size:12.5px;color:#9B9EA3;margin-top:6px;line-height:1.55\"\u003eDigitized from the published AutoPAC curve in the Pumps by Baker catalog (Sept 2025, rev 3\/26), p. 151, and rounded down. Rated flow (15 GPM) in bold. Zero flow is the shut-off point, a ceiling rather than a working point; — marks flows past the end of that curve.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBest operating range:\u003c\/strong\u003e the published curve shades the most efficient operating range; the catalog prints no figures for it. The curve is in the image gallery.\u003c\/p\u003e\n\u003cdiv style=\"display:flex;flex-wrap:wrap;gap:10px;margin:22px 0 4px\"\u003e\n\u003ca href=\"\/pages\/submersible-well-pump-sizing-calculator\" style=\"flex:1 1 200px;text-align:center;display:block;background:#B3122A;color:#ffffff;font-family:Arial Black,Arial,sans-serif;font-size:12px;text-transform:uppercase;letter-spacing:1.2px;padding:11px 18px;text-decoration:none\"\u003eSubmersible Calculator\u003c\/a\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eBefore You Buy — The Limits That Decide the Fit\u003c\/div\u003e\n\u003cdiv class=\"gs-lead\"\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply\u003c\/td\u003e\n\u003ctd\u003e230V single-phase for every build, from a circuit breaker sized per the table below\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure transducer\u003c\/td\u003e\n\u003ctd\u003eMust be installed upright and vertical (manufacturer note)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrive location\u003c\/td\u003e\n\u003ctd\u003eNEMA 3R enclosure, outdoors or indoors; rated to 122°F (104°F for SD3-5HP2); derate above 5500 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor cooling\u003c\/td\u003e\n\u003ctd\u003e1.0 ft\/sec of water flow past the motor at 95°F; motor rated to 95°F water\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWell size\u003c\/td\u003e\n\u003ctd\u003e4 in casing and larger\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePairing\u003c\/td\u003e\n\u003ctd\u003eOne pump and one drive per well\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"margin:14px 0 4px\"\u003e\u003cstrong\u003eBreaker sizing by motor HP (manufacturer recommendation)\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSupply\u003c\/th\u003e\n\u003cth\u003eMotor HP\u003c\/th\u003e\n\u003cth\u003eInput Current\u003c\/th\u003e\n\u003cth\u003eFuse \/ Breaker\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e230V\u003c\/td\u003e\n\u003ctd\u003e1\/2\u003c\/td\u003e\n\u003ctd\u003e6 A\u003c\/td\u003e\n\u003ctd\u003e10 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e230V\u003c\/td\u003e\n\u003ctd\u003e3\/4\u003c\/td\u003e\n\u003ctd\u003e9 A\u003c\/td\u003e\n\u003ctd\u003e15 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e230V\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003ctd\u003e14 A\u003c\/td\u003e\n\u003ctd\u003e20 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e230V\u003c\/td\u003e\n\u003ctd\u003e1 1\/2\u003c\/td\u003e\n\u003ctd\u003e18 A\u003c\/td\u003e\n\u003ctd\u003e25 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e230V\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e28 A\u003c\/td\u003e\n\u003ctd\u003e35 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e230V\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e20 A\u003c\/td\u003e\n\u003ctd\u003e25 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e230V\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003ctd\u003e30 A\u003c\/td\u003e\n\u003ctd\u003e40 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e230V\u003c\/td\u003e\n\u003ctd\u003e5\u003c\/td\u003e\n\u003ctd\u003e42 A\u003c\/td\u003e\n\u003ctd\u003e55 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"font-size:12.5px;color:#9B9EA3;margin-top:8px;line-height:1.55\"\u003eSource: Pumps by Baker catalog (Sept 2025, rev 3\/26), p. 131.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eMaterials of Construction (Pump)\u003c\/div\u003e\n\u003cdiv class=\"gs-lead\"\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eDischarge\u003c\/td\u003e\n\u003ctd\u003e300 series stainless steel, easy-wrench design with built-in safety eye; threads into the shell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCheck valve\u003c\/td\u003e\n\u003ctd\u003eBaker Diamond Design, easy-out for service\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDischarge bearing\u003c\/td\u003e\n\u003ctd\u003eRubber around the stainless steel shaft; self-lubricating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiffusers\u003c\/td\u003e\n\u003ctd\u003ePolycarbonate, corrosion and abrasion resistant, built for sand handling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eImpellers\u003c\/td\u003e\n\u003ctd\u003eGlass bead acetal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShaft\u003c\/td\u003e\n\u003ctd\u003e7\/16 in 300 series stainless steel, hex drive, each one measured for straightness\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShell\u003c\/td\u003e\n\u003ctd\u003eHeavy stainless steel, threaded at both ends for field service\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable guard\u003c\/td\u003e\n\u003ctd\u003eStainless steel; angled top keeps the leads in place\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor bracket\u003c\/td\u003e\n\u003ctd\u003eStainless steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"font-size:12.5px;color:#9B9EA3;margin-top:8px;line-height:1.55\"\u003eSource: Pumps by Baker catalog (Sept 2025, rev 3\/26), pp. 51-52.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eService Parts\u003c\/div\u003e\n\u003cdiv class=\"gs-lead\"\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003ePart\u003c\/th\u003e\n\u003cth\u003ePart No.\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutoDRIVE pressure transducer with 10 ft wire\u003c\/td\u003e\n\u003ctd\u003e6619-028\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutoDRIVE pressure switch with wire\u003c\/td\u003e\n\u003ctd\u003e6619-029\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutoDRIVE keypad\u003c\/td\u003e\n\u003ctd\u003e6619-030\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"font-size:12.5px;color:#9B9EA3;margin-top:8px;line-height:1.55\"\u003eSource: Pumps by Baker catalog (Sept 2025, rev 3\/26), pp. 142-143.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"gs-contact\"\u003eFor engineering-led sizing and selection support or a factory submittal, email \u003ca href=\"mailto:sales@watermainsupply.com\"\u003esales@watermainsupply.com\u003c\/a\u003e or call \u003ca href=\"tel:18885104036\"\u003e1-888.510.4036\u003c\/a\u003e.\u003cbr\u003e© Watermain Supply — A division of E4 Industrial LLC\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch5\u003eData Sheet\u003c\/h5\u003e\n\u003cdiv class=\"gs\"\u003e\n\u003cdiv class=\"gs-dl\"\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0264\/1913\/4527\/files\/AutoPac_Guide.pdf?v=1772502299\" target=\"_blank\" rel=\"noopener\"\u003ePumps by Baker AutoPac Guide\u003c\/a\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch5\u003eVideos\u003c\/h5\u003e\n\u003cdiv class=\"gs\"\u003e\u003cdiv class=\"gs-sec\" style=\"margin-top:6px\"\u003e\n\u003cp style=\"font-size:13px;color:#9B9EA3\"\u003eProduct videos are being added to this listing. For a walkthrough in the meantime, email sales@watermainsupply.com.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003c!-- \/TABS --\u003e","brand":"A.Y. McDonald","offers":[{"title":"1\/2 HP - 4 in Motor \/ 230V 1Ph 2-Wire \/ Switch - 23050L2-APS - 121 ft at 15 GPM","offer_id":46602928259247,"sku":"6630-586","price":2099.76,"currency_code":"USD","in_stock":true},{"title":"1\/2 HP - 4 in Motor \/ 230V 1Ph 2-Wire \/ Transducer - 23050L2-APT - 121 ft at 15 GPM","offer_id":46602928390319,"sku":"6630-580","price":2278.14,"currency_code":"USD","in_stock":true},{"title":"1\/2 HP - 4 in Motor \/ 230V 1Ph 3-Wire \/ Switch - 23050L3-APS - 121 ft at 15 GPM","offer_id":46602928521391,"sku":"6630-634","price":2013.37,"currency_code":"USD","in_stock":true},{"title":"1\/2 HP - 4 in Motor \/ 230V 1Ph 3-Wire \/ Transducer - 23050L3-APT - 121 ft at 15 GPM","offer_id":46602928685231,"sku":"6630-628","price":2192.78,"currency_code":"USD","in_stock":true},{"title":"3\/4 HP - 4 in Motor \/ 230V 1Ph 2-Wire \/ Switch - 23075L2-APS - 168 ft at 15 GPM","offer_id":46602928292015,"sku":"6630-598","price":2267.4,"currency_code":"USD","in_stock":true},{"title":"3\/4 HP - 4 in Motor \/ 230V 1Ph 2-Wire \/ Transducer - 23075L2-APT - 168 ft at 15 GPM","offer_id":46602928423087,"sku":"6630-592","price":2446.3,"currency_code":"USD","in_stock":true},{"title":"3\/4 HP - 4 in Motor \/ 230V 1Ph 3-Wire \/ Switch - 23075L3-APS - 168 ft at 15 GPM","offer_id":46602928554159,"sku":"6630-646","price":2152.41,"currency_code":"USD","in_stock":true},{"title":"3\/4 HP - 4 in Motor \/ 230V 1Ph 3-Wire \/ Transducer - 23075L3-APT - 168 ft at 15 GPM","offer_id":46602928717999,"sku":"6630-640","price":2330.27,"currency_code":"USD","in_stock":true},{"title":"1 HP - 4 in Motor \/ 230V 1Ph 2-Wire \/ Switch - 23100L2-APS - 207 ft at 15 GPM","offer_id":46602928324783,"sku":"6630-610","price":2374.23,"currency_code":"USD","in_stock":true},{"title":"1 HP - 4 in Motor \/ 230V 1Ph 2-Wire \/ Transducer - 23100L2-APT - 207 ft at 15 GPM","offer_id":46602928455855,"sku":"6630-604","price":2553.64,"currency_code":"USD","in_stock":true},{"title":"1 HP - 4 in Motor \/ 230V 1Ph 3-Wire \/ Switch - 23100L3-APS - 207 ft at 15 GPM","offer_id":46602928586927,"sku":"6630-658","price":2233.67,"currency_code":"USD","in_stock":true},{"title":"1 HP - 4 in Motor \/ 230V 1Ph 3-Wire \/ Transducer - 23100L3-APT - 207 ft at 15 GPM","offer_id":46602928750767,"sku":"6630-652","price":2412.06,"currency_code":"USD","in_stock":true},{"title":"1 HP - 4 in Motor \/ 230V 3Ph \/ Transducer - 23100L3Z-APT - 207 ft at 15 GPM","offer_id":46602928849071,"sku":"6630-885","price":2714.65,"currency_code":"USD","in_stock":true},{"title":"1 1\/2 HP - 4 in Motor \/ 230V 1Ph 2-Wire \/ Switch - 23150L2-APS - 277 ft at 15 GPM","offer_id":46602928357551,"sku":"6630-622","price":2530.68,"currency_code":"USD","in_stock":true},{"title":"1 1\/2 HP - 4 in Motor \/ 230V 1Ph 2-Wire \/ Transducer - 23150L2-APT - 277 ft at 15 GPM","offer_id":46602928488623,"sku":"6630-616","price":2709.05,"currency_code":"USD","in_stock":true},{"title":"1 1\/2 HP - 4 in Motor \/ 230V 1Ph 3-Wire \/ Switch - 23150L3-APS - 277 ft at 15 GPM","offer_id":46602928619695,"sku":"6630-670","price":2347.7,"currency_code":"USD","in_stock":true},{"title":"1 1\/2 HP - 4 in Motor \/ 230V 1Ph 3-Wire \/ Transducer - 23150L3-APT - 277 ft at 15 GPM","offer_id":46602928783535,"sku":"6630-664","price":2525.56,"currency_code":"USD","in_stock":true},{"title":"1 1\/2 HP - 4 in Motor \/ 230V 3Ph \/ Transducer - 23150L3Z-APT - 277 ft at 15 GPM","offer_id":46602928881839,"sku":"6630-852","price":2746.84,"currency_code":"USD","in_stock":true},{"title":"2 HP - 4 in Motor \/ 230V 1Ph 3-Wire \/ Switch - 23200L3-APS - 363 ft at 15 GPM","offer_id":46602928652463,"sku":"6630-680","price":2549.59,"currency_code":"USD","in_stock":true},{"title":"2 HP - 4 in Motor \/ 230V 1Ph 3-Wire \/ Transducer - 23200L3-APT - 363 ft at 15 GPM","offer_id":46602928816303,"sku":"6630-675","price":2728.48,"currency_code":"USD","in_stock":true},{"title":"2 HP - 4 in Motor \/ 230V 3Ph \/ Transducer - 23200L3Z-APT - 363 ft at 15 GPM","offer_id":46602928914607,"sku":"6630-685","price":2946.74,"currency_code":"USD","in_stock":true},{"title":"3 HP - 4 in Motor \/ 230V 3Ph \/ Transducer - 23300L3Z-APT - 484 ft at 15 GPM","offer_id":46602928947375,"sku":"6630-689","price":3656.18,"currency_code":"USD","in_stock":true},{"title":"5 HP - 4 in Motor \/ 230V 3Ph \/ Transducer - 23500L3Z-APT - 771 ft at 15 GPM","offer_id":46602928980143,"sku":"6630-693","price":5760.08,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0264\/1913\/4527\/files\/AutoPac_81c033b5-532b-466f-ac5e-25a5c7e7b071.png?v=1772502602"},{"product_id":"baker-autopac-p-20-gpm-23000-series","title":"A.Y. McDonald AutoPAC P - 20 GPM 23000 Constant Pressure Pump","description":"\u003c!-- TABS --\u003e\n\u003ch5\u003eDescription\u003c\/h5\u003e\n\u003cdiv class=\"gs\"\u003e\n\u003cdiv class=\"gs-head\"\u003e\n\u003cdiv class=\"gs-eyebrow\"\u003eA.Y. McDonald · Constant Pressure Pump System\u003c\/div\u003e\n\u003cdiv class=\"gs-title\"\u003eAutoPAC P - 20 GPM, 23000 Series\u003c\/div\u003e\n\u003cdiv class=\"gs-sub\"\u003eBaker domestic stainless steel 4 in submersible pump, motor and AutoDRIVE constant pressure drive, 1\/2 to 5 HP, 23 builds.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"gs-badges\"\u003e\n\u003cdiv class=\"gs-badge\" style=\"background:#B3122A;color:#FFFFFF;border-color:#B3122A\"\u003e93-644 ft at 20 GPM\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003e1\/2-5 HP\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003e230V Single-Phase Supply\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003eAutoDRIVE Constant Pressure VFD\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003ePressure Switch or Transducer Control\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003e958 ft Max Head (Shut-off)\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003e1 1\/4 in NPT Discharge\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003eNEMA 3R Drive Enclosure\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003e39-84 lb Weight\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background:#FFFFFF;border:1px solid #C7CBD1;border-top:3px solid #B3122A;padding:12px 16px 12px;margin:16px 0 4px;font-size:13.5px;line-height:1.55;color:#4A4A4F\"\u003e\n\u003cdiv style=\"font-family:Arial Black,Arial,sans-serif;font-size:11px;letter-spacing:1.2px;text-transform:uppercase;color:#B3122A;margin-bottom:8px\"\u003eWhat Ships and What It Needs to Run\u003c\/div\u003e\n\u003cp style=\"margin:0 0 6px\"\u003e\u003cstrong style=\"color:#B3122A\"\u003eIncluded:\u003c\/strong\u003e the pump end and Baker 4 in motor, assembled, with the AutoDRIVE constant pressure drive matched to the motor, and the pressure switch (APS models) or pressure transducer with 10 ft wire (APT models). The drive model for each build is in the Models table.\u003c\/p\u003e\n\u003cp style=\"margin:0 0 6px\"\u003e\u003cstrong style=\"color:#B3122A\"\u003ePower:\u003c\/strong\u003e 230V single-phase supply from a circuit breaker for every build; the three-phase builds take single-phase power and the drive makes three-phase for the motor. Breaker sizes are under Before You Buy.\u003c\/p\u003e\n\u003cp style=\"margin:0\"\u003e\u003cstrong style=\"color:#B3122A\"\u003eSized at install:\u003c\/strong\u003e drop cable, splice kit and the pressure relief valve shown in the manufacturer’s installation diagram.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eOverview\u003c\/div\u003e\n\u003cdiv class=\"gs-lead\"\u003e\n\u003cp\u003eThe AutoPAC is Baker’s constant pressure well package: a 23000 Series 4 in submersible pump, a Baker motor of the same horsepower, and the AutoDRIVE variable frequency drive. The drive holds a set pressure by changing the pump speed, which allows a smaller pressure tank and a quick, simple installation; setup takes 5 steps or less on the drive’s backlit display.\u003c\/p\u003e\n\u003cp\u003eThis listing is the \u003cstrong\u003eP - 20 GPM\u003c\/strong\u003e class: 1\/2 to 5 HP, with pressure switch and transducer control. The AutoDRIVE is American made and housed in a NEMA 3R steel enclosure rated for outdoor use.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background:#E1E3E6;border-left:3px solid #B8BDC4;padding:8px 14px;font-size:11.5px;color:#4A4A4F;margin-top:14px;line-height:1.5\"\u003eGenuine A.Y. McDonald equipment, factory-new in original packaging — sold and supported by Watermain Supply, an independent industrial supplier. Watermain Supply is an Authorized Stocking A.Y. McDonald and Baker Water Systems Distributor.\u003c\/div\u003e\n\u003cdiv style=\"background:#fff;border-left:5px solid #B3122A;padding:15px 18px;margin-top:12px\"\u003e\n\u003cdiv style=\"font-family:Arial Black,Arial,sans-serif;font-size:15px;color:#B3122A;text-transform:uppercase;letter-spacing:1px;margin-bottom:6px\"\u003eA.Y. McDonald Warranty\u003c\/div\u003e\n\u003cp style=\"margin:0;font-size:13.5px;color:#4A4A4F;line-height:1.55\"\u003ePump and motor: covered for \u003cstrong\u003e5 years from the date of manufacture in potable water applications\u003c\/strong\u003e, and 3 years from the date of manufacture in other applications, under A.Y. McDonald’s published terms for Baker submersible motors and assembled submersible pumps. The AutoDRIVE and pressure control fall under A.Y. McDonald’s standard limited warranty: 2 years from the date of manufacture or 1 year from installation, whichever comes first.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eRoom to Grow\u003c\/div\u003e\n\u003cdiv class=\"gs-lead\"\u003e\n\u003cp\u003eOne pump and one drive per well. Need more head later? Step up in horsepower within the P - 20 GPM class; the drive model changes with the motor (see the Models table). Need more flow? Move to a higher flow class of the AutoPAC 23000 Series; every class uses the same 1 1\/4 in NPT discharge.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eModels \u0026amp; Ratings (60 Hz)\u003c\/div\u003e\n\u003cdiv class=\"gs-lead\"\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003cth\u003ePart No.\u003c\/th\u003e\n\u003cth\u003eHP\u003c\/th\u003e\n\u003cth\u003eMotor\u003c\/th\u003e\n\u003cth\u003eControl\u003c\/th\u003e\n\u003cth\u003eAutoDRIVE\u003c\/th\u003e\n\u003cth\u003eHead at 20 GPM\u003c\/th\u003e\n\u003cth\u003eShut-off Head\u003c\/th\u003e\n\u003cth\u003eWeight\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e23050P2-APS\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6630-587\u003c\/td\u003e\n\u003ctd\u003e1\/2\u003c\/td\u003e\n\u003ctd\u003e230V 1Ph 2-Wire\u003c\/td\u003e\n\u003ctd\u003ePressure Switch\u003c\/td\u003e\n\u003ctd\u003eSD1-2HP2PS\u003c\/td\u003e\n\u003ctd\u003e93 ft\u003c\/td\u003e\n\u003ctd\u003e146 ft\u003c\/td\u003e\n\u003ctd\u003e41 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e23050P2-APT\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6630-581\u003c\/td\u003e\n\u003ctd\u003e1\/2\u003c\/td\u003e\n\u003ctd\u003e230V 1Ph 2-Wire\u003c\/td\u003e\n\u003ctd\u003eTransducer\u003c\/td\u003e\n\u003ctd\u003eSD1-2HP2\u003c\/td\u003e\n\u003ctd\u003e93 ft\u003c\/td\u003e\n\u003ctd\u003e146 ft\u003c\/td\u003e\n\u003ctd\u003e41 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e23050P3-APS\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6630-635\u003c\/td\u003e\n\u003ctd\u003e1\/2\u003c\/td\u003e\n\u003ctd\u003e230V 1Ph 3-Wire\u003c\/td\u003e\n\u003ctd\u003ePressure Switch\u003c\/td\u003e\n\u003ctd\u003eSD1-2HP2PS\u003c\/td\u003e\n\u003ctd\u003e93 ft\u003c\/td\u003e\n\u003ctd\u003e146 ft\u003c\/td\u003e\n\u003ctd\u003e39 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e23050P3-APT\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6630-629\u003c\/td\u003e\n\u003ctd\u003e1\/2\u003c\/td\u003e\n\u003ctd\u003e230V 1Ph 3-Wire\u003c\/td\u003e\n\u003ctd\u003eTransducer\u003c\/td\u003e\n\u003ctd\u003eSD1-2HP2\u003c\/td\u003e\n\u003ctd\u003e93 ft\u003c\/td\u003e\n\u003ctd\u003e146 ft\u003c\/td\u003e\n\u003ctd\u003e39 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e23075P2-APS\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6630-599\u003c\/td\u003e\n\u003ctd\u003e3\/4\u003c\/td\u003e\n\u003ctd\u003e230V 1Ph 2-Wire\u003c\/td\u003e\n\u003ctd\u003ePressure Switch\u003c\/td\u003e\n\u003ctd\u003eSD1-2HP2PS\u003c\/td\u003e\n\u003ctd\u003e136 ft\u003c\/td\u003e\n\u003ctd\u003e203 ft\u003c\/td\u003e\n\u003ctd\u003e44 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e23075P2-APT\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6630-593\u003c\/td\u003e\n\u003ctd\u003e3\/4\u003c\/td\u003e\n\u003ctd\u003e230V 1Ph 2-Wire\u003c\/td\u003e\n\u003ctd\u003eTransducer\u003c\/td\u003e\n\u003ctd\u003eSD1-2HP2\u003c\/td\u003e\n\u003ctd\u003e136 ft\u003c\/td\u003e\n\u003ctd\u003e203 ft\u003c\/td\u003e\n\u003ctd\u003e44 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e23075P3-APS\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6630-647\u003c\/td\u003e\n\u003ctd\u003e3\/4\u003c\/td\u003e\n\u003ctd\u003e230V 1Ph 3-Wire\u003c\/td\u003e\n\u003ctd\u003ePressure Switch\u003c\/td\u003e\n\u003ctd\u003eSD1-2HP2PS\u003c\/td\u003e\n\u003ctd\u003e136 ft\u003c\/td\u003e\n\u003ctd\u003e203 ft\u003c\/td\u003e\n\u003ctd\u003e41 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e23075P3-APT\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6630-641\u003c\/td\u003e\n\u003ctd\u003e3\/4\u003c\/td\u003e\n\u003ctd\u003e230V 1Ph 3-Wire\u003c\/td\u003e\n\u003ctd\u003eTransducer\u003c\/td\u003e\n\u003ctd\u003eSD1-2HP2\u003c\/td\u003e\n\u003ctd\u003e136 ft\u003c\/td\u003e\n\u003ctd\u003e203 ft\u003c\/td\u003e\n\u003ctd\u003e41 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e23100P2-APS\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6630-611\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003ctd\u003e230V 1Ph 2-Wire\u003c\/td\u003e\n\u003ctd\u003ePressure Switch\u003c\/td\u003e\n\u003ctd\u003eSD1-2HP2PS\u003c\/td\u003e\n\u003ctd\u003e166 ft\u003c\/td\u003e\n\u003ctd\u003e261 ft\u003c\/td\u003e\n\u003ctd\u003e50 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e23100P2-APT\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6630-605\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003ctd\u003e230V 1Ph 2-Wire\u003c\/td\u003e\n\u003ctd\u003eTransducer\u003c\/td\u003e\n\u003ctd\u003eSD1-2HP2\u003c\/td\u003e\n\u003ctd\u003e166 ft\u003c\/td\u003e\n\u003ctd\u003e261 ft\u003c\/td\u003e\n\u003ctd\u003e50 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e23100P3-APS\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6630-659\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003ctd\u003e230V 1Ph 3-Wire\u003c\/td\u003e\n\u003ctd\u003ePressure Switch\u003c\/td\u003e\n\u003ctd\u003eSD1-2HP2PS\u003c\/td\u003e\n\u003ctd\u003e166 ft\u003c\/td\u003e\n\u003ctd\u003e261 ft\u003c\/td\u003e\n\u003ctd\u003e49 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e23100P3-APT\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6630-653\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003ctd\u003e230V 1Ph 3-Wire\u003c\/td\u003e\n\u003ctd\u003eTransducer\u003c\/td\u003e\n\u003ctd\u003eSD1-2HP2\u003c\/td\u003e\n\u003ctd\u003e166 ft\u003c\/td\u003e\n\u003ctd\u003e261 ft\u003c\/td\u003e\n\u003ctd\u003e49 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e23100P3Z-APT\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6630-886\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003ctd\u003e230V 3Ph\u003c\/td\u003e\n\u003ctd\u003eTransducer\u003c\/td\u003e\n\u003ctd\u003eSD3-2HP2\u003c\/td\u003e\n\u003ctd\u003e166 ft\u003c\/td\u003e\n\u003ctd\u003e261 ft\u003c\/td\u003e\n\u003ctd\u003e50 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e23150P2-APS\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6630-623\u003c\/td\u003e\n\u003ctd\u003e1 1\/2\u003c\/td\u003e\n\u003ctd\u003e230V 1Ph 2-Wire\u003c\/td\u003e\n\u003ctd\u003ePressure Switch\u003c\/td\u003e\n\u003ctd\u003eSD1-2HP2PS\u003c\/td\u003e\n\u003ctd\u003e235 ft\u003c\/td\u003e\n\u003ctd\u003e358 ft\u003c\/td\u003e\n\u003ctd\u003e56 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e23150P2-APT\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6630-617\u003c\/td\u003e\n\u003ctd\u003e1 1\/2\u003c\/td\u003e\n\u003ctd\u003e230V 1Ph 2-Wire\u003c\/td\u003e\n\u003ctd\u003eTransducer\u003c\/td\u003e\n\u003ctd\u003eSD1-2HP2\u003c\/td\u003e\n\u003ctd\u003e235 ft\u003c\/td\u003e\n\u003ctd\u003e358 ft\u003c\/td\u003e\n\u003ctd\u003e56 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e23150P3-APS\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6630-671\u003c\/td\u003e\n\u003ctd\u003e1 1\/2\u003c\/td\u003e\n\u003ctd\u003e230V 1Ph 3-Wire\u003c\/td\u003e\n\u003ctd\u003ePressure Switch\u003c\/td\u003e\n\u003ctd\u003eSD1-2HP2PS\u003c\/td\u003e\n\u003ctd\u003e235 ft\u003c\/td\u003e\n\u003ctd\u003e358 ft\u003c\/td\u003e\n\u003ctd\u003e55 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e23150P3-APT\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6630-665\u003c\/td\u003e\n\u003ctd\u003e1 1\/2\u003c\/td\u003e\n\u003ctd\u003e230V 1Ph 3-Wire\u003c\/td\u003e\n\u003ctd\u003eTransducer\u003c\/td\u003e\n\u003ctd\u003eSD1-2HP2\u003c\/td\u003e\n\u003ctd\u003e235 ft\u003c\/td\u003e\n\u003ctd\u003e358 ft\u003c\/td\u003e\n\u003ctd\u003e55 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e23150P3Z-APT\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6630-853\u003c\/td\u003e\n\u003ctd\u003e1 1\/2\u003c\/td\u003e\n\u003ctd\u003e230V 3Ph\u003c\/td\u003e\n\u003ctd\u003eTransducer\u003c\/td\u003e\n\u003ctd\u003eSD3-2HP2\u003c\/td\u003e\n\u003ctd\u003e235 ft\u003c\/td\u003e\n\u003ctd\u003e358 ft\u003c\/td\u003e\n\u003ctd\u003e48 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e23200P3-APS\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6630-681\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e230V 1Ph 3-Wire\u003c\/td\u003e\n\u003ctd\u003ePressure Switch\u003c\/td\u003e\n\u003ctd\u003eSD1-2HP2PS\u003c\/td\u003e\n\u003ctd\u003e302 ft\u003c\/td\u003e\n\u003ctd\u003e462 ft\u003c\/td\u003e\n\u003ctd\u003e56 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e23200P3-APT\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6630-676\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e230V 1Ph 3-Wire\u003c\/td\u003e\n\u003ctd\u003eTransducer\u003c\/td\u003e\n\u003ctd\u003eSD1-2HP2\u003c\/td\u003e\n\u003ctd\u003e302 ft\u003c\/td\u003e\n\u003ctd\u003e462 ft\u003c\/td\u003e\n\u003ctd\u003e56 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e23200P3Z-APT\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6630-686\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e230V 3Ph\u003c\/td\u003e\n\u003ctd\u003eTransducer\u003c\/td\u003e\n\u003ctd\u003eSD3-2HP2\u003c\/td\u003e\n\u003ctd\u003e302 ft\u003c\/td\u003e\n\u003ctd\u003e462 ft\u003c\/td\u003e\n\u003ctd\u003e54 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e23300P3Z-APT\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6630-690\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003ctd\u003e230V 3Ph\u003c\/td\u003e\n\u003ctd\u003eTransducer\u003c\/td\u003e\n\u003ctd\u003eSD3-3HP2\u003c\/td\u003e\n\u003ctd\u003e394 ft\u003c\/td\u003e\n\u003ctd\u003e602 ft\u003c\/td\u003e\n\u003ctd\u003e68 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e23500P3Z-APT\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6630-694\u003c\/td\u003e\n\u003ctd\u003e5\u003c\/td\u003e\n\u003ctd\u003e230V 3Ph\u003c\/td\u003e\n\u003ctd\u003eTransducer\u003c\/td\u003e\n\u003ctd\u003eSD3-5HP2\u003c\/td\u003e\n\u003ctd\u003e644 ft\u003c\/td\u003e\n\u003ctd\u003e958 ft\u003c\/td\u003e\n\u003ctd\u003e84 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"font-size:12.5px;color:#9B9EA3;margin-top:8px;line-height:1.55\"\u003eHead at 20 GPM is read from the published AutoPAC curve (Pumps by Baker catalog (Sept 2025, rev 3\/26), p. 153), digitized and rounded down. Shut-off head as printed. Drive per the compatibility table on p. 141 (1 1\/2 HP three-phase builds use the SD3-2HP2). Sources: Pumps by Baker catalog (Sept 2025, rev 3\/26), pp. 141-143 and 153; Baker Pumps and Accessories price list, effective 7\/1\/2026.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eShared Specifications\u003c\/div\u003e\n\u003cdiv class=\"gs-lead\"\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eIncluded\u003c\/td\u003e\n\u003ctd\u003ePump end, Baker 4 in motor, AutoDRIVE drive, and pressure switch or transducer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDischarge\u003c\/td\u003e\n\u003ctd\u003e1 1\/4 in NPT (female)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCheck valve\u003c\/td\u003e\n\u003ctd\u003eBuilt in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply\u003c\/td\u003e\n\u003ctd\u003e230V single-phase, 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor\u003c\/td\u003e\n\u003ctd\u003eBaker 4 in submersible motor, matched to the pump end horsepower\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePump diameter\u003c\/td\u003e\n\u003ctd\u003e3 3\/4 in with cable guard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrive enclosure\u003c\/td\u003e\n\u003ctd\u003eNEMA Type 3R steel, 12.25 x 9.25 x 4.68 in, 13 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrive operating temperature\u003c\/td\u003e\n\u003ctd\u003e-4 to 122°F; SD3-5HP2 rated to 104°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrive efficiency\u003c\/td\u003e\n\u003ctd\u003e95%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApp connection\u003c\/td\u003e\n\u003ctd\u003eNone; set up on the drive display\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"font-size:12.5px;color:#9B9EA3;margin-top:8px;line-height:1.55\"\u003eSource: Pumps by Baker catalog (Sept 2025, rev 3\/26), pp. 131-133 and 141-143.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003ePerformance — Will It Do What You Need?\u003c\/div\u003e\n\u003cdiv class=\"gs-lead\"\u003e\n\u003cp\u003e\u003cstrong\u003eTotal head\u003c\/strong\u003e is everything the pump lifts against: the vertical lift from the pumping water level to the discharge, the pressure you set on the drive (2.31 ft for every PSI), and friction in the drop pipe. The drive slows the pump when demand falls, so the curve below is the most the pump delivers at full speed.\u003c\/p\u003e\n\u003cp style=\"margin-bottom:4px\"\u003e\u003cstrong\u003eTotal head in feet, by flow in GPM, at full speed\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eHP (stages)\u003c\/th\u003e\n\u003cth\u003e0\u003c\/th\u003e\n\u003cth\u003e5\u003c\/th\u003e\n\u003cth\u003e10\u003c\/th\u003e\n\u003cth\u003e15\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003e20\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e25\u003c\/th\u003e\n\u003cth\u003e30\u003c\/th\u003e\n\u003cth\u003e35\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e1\/2 HP (5)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e152\u003c\/td\u003e\n\u003ctd\u003e141\u003c\/td\u003e\n\u003ctd\u003e128\u003c\/td\u003e\n\u003ctd\u003e112\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e93\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e72\u003c\/td\u003e\n\u003ctd\u003e43\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e3\/4 HP (7)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e210\u003c\/td\u003e\n\u003ctd\u003e196\u003c\/td\u003e\n\u003ctd\u003e179\u003c\/td\u003e\n\u003ctd\u003e161\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e136\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e103\u003c\/td\u003e\n\u003ctd\u003e62\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e1 HP (9)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e259\u003c\/td\u003e\n\u003ctd\u003e248\u003c\/td\u003e\n\u003ctd\u003e230\u003c\/td\u003e\n\u003ctd\u003e205\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e166\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e122\u003c\/td\u003e\n\u003ctd\u003e73\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e1 1\/2 HP (12)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e359\u003c\/td\u003e\n\u003ctd\u003e346\u003c\/td\u003e\n\u003ctd\u003e324\u003c\/td\u003e\n\u003ctd\u003e286\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e235\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e173\u003c\/td\u003e\n\u003ctd\u003e100\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e2 HP (14)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e459\u003c\/td\u003e\n\u003ctd\u003e437\u003c\/td\u003e\n\u003ctd\u003e406\u003c\/td\u003e\n\u003ctd\u003e360\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e302\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e237\u003c\/td\u003e\n\u003ctd\u003e144\u003c\/td\u003e\n\u003ctd\u003e41\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e3 HP (20)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e600\u003c\/td\u003e\n\u003ctd\u003e573\u003c\/td\u003e\n\u003ctd\u003e527\u003c\/td\u003e\n\u003ctd\u003e465\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e394\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e299\u003c\/td\u003e\n\u003ctd\u003e180\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e5 HP (32)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e959\u003c\/td\u003e\n\u003ctd\u003e903\u003c\/td\u003e\n\u003ctd\u003e841\u003c\/td\u003e\n\u003ctd\u003e765\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e644\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e477\u003c\/td\u003e\n\u003ctd\u003e281\u003c\/td\u003e\n\u003ctd\u003e41\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"font-size:12.5px;color:#9B9EA3;margin-top:6px;line-height:1.55\"\u003eDigitized from the published AutoPAC curve in the Pumps by Baker catalog (Sept 2025, rev 3\/26), p. 153, and rounded down. Rated flow (20 GPM) in bold. Zero flow is the shut-off point, a ceiling rather than a working point; — marks flows past the end of that curve.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBest operating range:\u003c\/strong\u003e the published curve shades the most efficient operating range; the catalog prints no figures for it. The curve is in the image gallery.\u003c\/p\u003e\n\u003cdiv style=\"display:flex;flex-wrap:wrap;gap:10px;margin:22px 0 4px\"\u003e\n\u003ca href=\"\/pages\/submersible-well-pump-sizing-calculator\" style=\"flex:1 1 200px;text-align:center;display:block;background:#B3122A;color:#ffffff;font-family:Arial Black,Arial,sans-serif;font-size:12px;text-transform:uppercase;letter-spacing:1.2px;padding:11px 18px;text-decoration:none\"\u003eSubmersible Calculator\u003c\/a\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eBefore You Buy — The Limits That Decide the Fit\u003c\/div\u003e\n\u003cdiv class=\"gs-lead\"\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply\u003c\/td\u003e\n\u003ctd\u003e230V single-phase for every build, from a circuit breaker sized per the table below\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure transducer\u003c\/td\u003e\n\u003ctd\u003eMust be installed upright and vertical (manufacturer note)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrive location\u003c\/td\u003e\n\u003ctd\u003eNEMA 3R enclosure, outdoors or indoors; rated to 122°F (104°F for SD3-5HP2); derate above 5500 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor cooling\u003c\/td\u003e\n\u003ctd\u003e1.0 ft\/sec of water flow past the motor at 95°F; motor rated to 95°F water\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWell size\u003c\/td\u003e\n\u003ctd\u003e4 in casing and larger\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePairing\u003c\/td\u003e\n\u003ctd\u003eOne pump and one drive per well\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"margin:14px 0 4px\"\u003e\u003cstrong\u003eBreaker sizing by motor HP (manufacturer recommendation)\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSupply\u003c\/th\u003e\n\u003cth\u003eMotor HP\u003c\/th\u003e\n\u003cth\u003eInput Current\u003c\/th\u003e\n\u003cth\u003eFuse \/ Breaker\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e230V\u003c\/td\u003e\n\u003ctd\u003e1\/2\u003c\/td\u003e\n\u003ctd\u003e6 A\u003c\/td\u003e\n\u003ctd\u003e10 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e230V\u003c\/td\u003e\n\u003ctd\u003e3\/4\u003c\/td\u003e\n\u003ctd\u003e9 A\u003c\/td\u003e\n\u003ctd\u003e15 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e230V\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003ctd\u003e14 A\u003c\/td\u003e\n\u003ctd\u003e20 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e230V\u003c\/td\u003e\n\u003ctd\u003e1 1\/2\u003c\/td\u003e\n\u003ctd\u003e18 A\u003c\/td\u003e\n\u003ctd\u003e25 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e230V\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e28 A\u003c\/td\u003e\n\u003ctd\u003e35 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e230V\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e20 A\u003c\/td\u003e\n\u003ctd\u003e25 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e230V\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003ctd\u003e30 A\u003c\/td\u003e\n\u003ctd\u003e40 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e230V\u003c\/td\u003e\n\u003ctd\u003e5\u003c\/td\u003e\n\u003ctd\u003e42 A\u003c\/td\u003e\n\u003ctd\u003e55 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"font-size:12.5px;color:#9B9EA3;margin-top:8px;line-height:1.55\"\u003eSource: Pumps by Baker catalog (Sept 2025, rev 3\/26), p. 131.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eMaterials of Construction (Pump)\u003c\/div\u003e\n\u003cdiv class=\"gs-lead\"\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eDischarge\u003c\/td\u003e\n\u003ctd\u003e300 series stainless steel, easy-wrench design with built-in safety eye; threads into the shell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCheck valve\u003c\/td\u003e\n\u003ctd\u003eBaker Diamond Design, easy-out for service\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDischarge bearing\u003c\/td\u003e\n\u003ctd\u003eRubber around the stainless steel shaft; self-lubricating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiffusers\u003c\/td\u003e\n\u003ctd\u003ePolycarbonate, corrosion and abrasion resistant, built for sand handling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eImpellers\u003c\/td\u003e\n\u003ctd\u003eGlass bead acetal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShaft\u003c\/td\u003e\n\u003ctd\u003e7\/16 in 300 series stainless steel, hex drive, each one measured for straightness\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShell\u003c\/td\u003e\n\u003ctd\u003eHeavy stainless steel, threaded at both ends for field service\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable guard\u003c\/td\u003e\n\u003ctd\u003eStainless steel; angled top keeps the leads in place\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor bracket\u003c\/td\u003e\n\u003ctd\u003eStainless steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"font-size:12.5px;color:#9B9EA3;margin-top:8px;line-height:1.55\"\u003eSource: Pumps by Baker catalog (Sept 2025, rev 3\/26), pp. 51-52.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eService Parts\u003c\/div\u003e\n\u003cdiv class=\"gs-lead\"\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003ePart\u003c\/th\u003e\n\u003cth\u003ePart No.\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutoDRIVE pressure transducer with 10 ft wire\u003c\/td\u003e\n\u003ctd\u003e6619-028\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutoDRIVE pressure switch with wire\u003c\/td\u003e\n\u003ctd\u003e6619-029\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutoDRIVE keypad\u003c\/td\u003e\n\u003ctd\u003e6619-030\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"font-size:12.5px;color:#9B9EA3;margin-top:8px;line-height:1.55\"\u003eSource: Pumps by Baker catalog (Sept 2025, rev 3\/26), pp. 142-143.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"gs-contact\"\u003eFor engineering-led sizing and selection support or a factory submittal, email \u003ca href=\"mailto:sales@watermainsupply.com\"\u003esales@watermainsupply.com\u003c\/a\u003e or call \u003ca href=\"tel:18885104036\"\u003e1-888.510.4036\u003c\/a\u003e.\u003cbr\u003e© Watermain Supply — A division of E4 Industrial LLC\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch5\u003eData Sheet\u003c\/h5\u003e\n\u003cdiv class=\"gs\"\u003e\n\u003cdiv class=\"gs-dl\"\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0264\/1913\/4527\/files\/AutoPac_Guide.pdf?v=1772502299\" target=\"_blank\" rel=\"noopener\"\u003ePumps by Baker AutoPac Guide\u003c\/a\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch5\u003eVideos\u003c\/h5\u003e\n\u003cdiv class=\"gs\"\u003e\u003cdiv class=\"gs-sec\" style=\"margin-top:6px\"\u003e\n\u003cp style=\"font-size:13px;color:#9B9EA3\"\u003eProduct videos are being added to this listing. For a walkthrough in the meantime, email sales@watermainsupply.com.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003c!-- \/TABS --\u003e","brand":"A.Y. McDonald","offers":[{"title":"1\/2 HP - 4 in Motor \/ 230V 1Ph 2-Wire \/ Switch - 23050P2-APS - 93 ft at 20 GPM","offer_id":46602929012911,"sku":"6630-587","price":2082.89,"currency_code":"USD","in_stock":true},{"title":"1\/2 HP - 4 in Motor \/ 230V 1Ph 2-Wire \/ Transducer - 23050P2-APT - 93 ft at 20 GPM","offer_id":46602929143983,"sku":"6630-581","price":2261.77,"currency_code":"USD","in_stock":true},{"title":"1\/2 HP - 4 in Motor \/ 230V 1Ph 3-Wire \/ Switch - 23050P3-APS - 93 ft at 20 GPM","offer_id":46602929275055,"sku":"6630-635","price":1997.53,"currency_code":"USD","in_stock":true},{"title":"1\/2 HP - 4 in Motor \/ 230V 1Ph 3-Wire \/ Transducer - 23050P3-APT - 93 ft at 20 GPM","offer_id":46602929438895,"sku":"6630-629","price":2175.91,"currency_code":"USD","in_stock":true},{"title":"3\/4 HP - 4 in Motor \/ 230V 1Ph 2-Wire \/ Switch - 23075P2-APS - 136 ft at 20 GPM","offer_id":46602929045679,"sku":"6630-599","price":2287.85,"currency_code":"USD","in_stock":true},{"title":"3\/4 HP - 4 in Motor \/ 230V 1Ph 2-Wire \/ Transducer - 23075P2-APT - 136 ft at 20 GPM","offer_id":46602929176751,"sku":"6630-593","price":2465.71,"currency_code":"USD","in_stock":true},{"title":"3\/4 HP - 4 in Motor \/ 230V 1Ph 3-Wire \/ Switch - 23075P3-APS - 136 ft at 20 GPM","offer_id":46602929307823,"sku":"6630-647","price":2172.33,"currency_code":"USD","in_stock":true},{"title":"3\/4 HP - 4 in Motor \/ 230V 1Ph 3-Wire \/ Transducer - 23075P3-APT - 136 ft at 20 GPM","offer_id":46602929471663,"sku":"6630-641","price":2351.23,"currency_code":"USD","in_stock":true},{"title":"1 HP - 4 in Motor \/ 230V 1Ph 2-Wire \/ Switch - 23100P2-APS - 166 ft at 20 GPM","offer_id":46602929078447,"sku":"6630-611","price":2359.41,"currency_code":"USD","in_stock":true},{"title":"1 HP - 4 in Motor \/ 230V 1Ph 2-Wire \/ Transducer - 23100P2-APT - 166 ft at 20 GPM","offer_id":46602929209519,"sku":"6630-605","price":2537.79,"currency_code":"USD","in_stock":true},{"title":"1 HP - 4 in Motor \/ 230V 1Ph 3-Wire \/ Switch - 23100P3-APS - 166 ft at 20 GPM","offer_id":46602929340591,"sku":"6630-659","price":2218.33,"currency_code":"USD","in_stock":true},{"title":"1 HP - 4 in Motor \/ 230V 1Ph 3-Wire \/ Transducer - 23100P3-APT - 166 ft at 20 GPM","offer_id":46602929504431,"sku":"6630-653","price":2397.74,"currency_code":"USD","in_stock":true},{"title":"1 HP - 4 in Motor \/ 230V 3Ph \/ Transducer - 23100P3Z-APT - 166 ft at 20 GPM","offer_id":46602929602735,"sku":"6630-886","price":2664.56,"currency_code":"USD","in_stock":true},{"title":"1 1\/2 HP - 4 in Motor \/ 230V 1Ph 2-Wire \/ Switch - 23150P2-APS - 235 ft at 20 GPM","offer_id":46602929111215,"sku":"6630-623","price":2551.13,"currency_code":"USD","in_stock":true},{"title":"1 1\/2 HP - 4 in Motor \/ 230V 1Ph 2-Wire \/ Transducer - 23150P2-APT - 235 ft at 20 GPM","offer_id":46602929242287,"sku":"6630-617","price":2729.5,"currency_code":"USD","in_stock":true},{"title":"1 1\/2 HP - 4 in Motor \/ 230V 1Ph 3-Wire \/ Switch - 23150P3-APS - 235 ft at 20 GPM","offer_id":46602929373359,"sku":"6630-671","price":2367.11,"currency_code":"USD","in_stock":true},{"title":"1 1\/2 HP - 4 in Motor \/ 230V 1Ph 3-Wire \/ Transducer - 23150P3-APT - 235 ft at 20 GPM","offer_id":46602929537199,"sku":"6630-665","price":2545.5,"currency_code":"USD","in_stock":true},{"title":"1 1\/2 HP - 4 in Motor \/ 230V 3Ph \/ Transducer - 23150P3Z-APT - 235 ft at 20 GPM","offer_id":46602929635503,"sku":"6630-853","price":2767.8,"currency_code":"USD","in_stock":true},{"title":"2 HP - 4 in Motor \/ 230V 1Ph 3-Wire \/ Switch - 23200P3-APS - 302 ft at 20 GPM","offer_id":46602929406127,"sku":"6630-681","price":2769.37,"currency_code":"USD","in_stock":true},{"title":"2 HP - 4 in Motor \/ 230V 1Ph 3-Wire \/ Transducer - 23200P3-APT - 302 ft at 20 GPM","offer_id":46602929569967,"sku":"6630-676","price":2948.78,"currency_code":"USD","in_stock":true},{"title":"2 HP - 4 in Motor \/ 230V 3Ph \/ Transducer - 23200P3Z-APT - 302 ft at 20 GPM","offer_id":46602929668271,"sku":"6630-686","price":3166.51,"currency_code":"USD","in_stock":true},{"title":"3 HP - 4 in Motor \/ 230V 3Ph \/ Transducer - 23300P3Z-APT - 394 ft at 20 GPM","offer_id":46602929701039,"sku":"6630-690","price":3913.28,"currency_code":"USD","in_stock":true},{"title":"5 HP - 4 in Motor \/ 230V 3Ph \/ Transducer - 23500P3Z-APT - 644 ft at 20 GPM","offer_id":46602929733807,"sku":"6630-694","price":5446.75,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0264\/1913\/4527\/files\/AutoPac_1209e2d8-4660-4888-bae9-4eae329e2f32.png?v=1772502604"},{"product_id":"baker-autopac-m-25-gpm-23000-series","title":"A.Y. McDonald AutoPAC M - 25 GPM 23000 Constant Pressure Pump","description":"\u003c!-- TABS --\u003e\n\u003ch5\u003eDescription\u003c\/h5\u003e\n\u003cdiv class=\"gs\"\u003e\n\u003cdiv class=\"gs-head\"\u003e\n\u003cdiv class=\"gs-eyebrow\"\u003eA.Y. McDonald · Constant Pressure Pump System\u003c\/div\u003e\n\u003cdiv class=\"gs-title\"\u003eAutoPAC M - 25 GPM, 23000 Series\u003c\/div\u003e\n\u003cdiv class=\"gs-sub\"\u003eBaker domestic stainless steel 4 in submersible pump, motor and AutoDRIVE constant pressure drive, 1\/2 to 5 HP, 23 builds.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"gs-badges\"\u003e\n\u003cdiv class=\"gs-badge\" style=\"background:#B3122A;color:#FFFFFF;border-color:#B3122A\"\u003e64-480 ft at 25 GPM\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003e1\/2-5 HP\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003e230V Single-Phase Supply\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003eAutoDRIVE Constant Pressure VFD\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003ePressure Switch or Transducer Control\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003e796 ft Max Head (Shut-off)\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003e1 1\/4 in NPT Discharge\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003eNEMA 3R Drive Enclosure\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003e39-80 lb Weight\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background:#FFFFFF;border:1px solid #C7CBD1;border-top:3px solid #B3122A;padding:12px 16px 12px;margin:16px 0 4px;font-size:13.5px;line-height:1.55;color:#4A4A4F\"\u003e\n\u003cdiv style=\"font-family:Arial Black,Arial,sans-serif;font-size:11px;letter-spacing:1.2px;text-transform:uppercase;color:#B3122A;margin-bottom:8px\"\u003eWhat Ships and What It Needs to Run\u003c\/div\u003e\n\u003cp style=\"margin:0 0 6px\"\u003e\u003cstrong style=\"color:#B3122A\"\u003eIncluded:\u003c\/strong\u003e the pump end and Baker 4 in motor, assembled, with the AutoDRIVE constant pressure drive matched to the motor, and the pressure switch (APS models) or pressure transducer with 10 ft wire (APT models). The drive model for each build is in the Models table.\u003c\/p\u003e\n\u003cp style=\"margin:0 0 6px\"\u003e\u003cstrong style=\"color:#B3122A\"\u003ePower:\u003c\/strong\u003e 230V single-phase supply from a circuit breaker for every build; the three-phase builds take single-phase power and the drive makes three-phase for the motor. Breaker sizes are under Before You Buy.\u003c\/p\u003e\n\u003cp style=\"margin:0\"\u003e\u003cstrong style=\"color:#B3122A\"\u003eSized at install:\u003c\/strong\u003e drop cable, splice kit and the pressure relief valve shown in the manufacturer’s installation diagram.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eOverview\u003c\/div\u003e\n\u003cdiv class=\"gs-lead\"\u003e\n\u003cp\u003eThe AutoPAC is Baker’s constant pressure well package: a 23000 Series 4 in submersible pump, a Baker motor of the same horsepower, and the AutoDRIVE variable frequency drive. The drive holds a set pressure by changing the pump speed, which allows a smaller pressure tank and a quick, simple installation; setup takes 5 steps or less on the drive’s backlit display.\u003c\/p\u003e\n\u003cp\u003eThis listing is the \u003cstrong\u003eM - 25 GPM\u003c\/strong\u003e class: 1\/2 to 5 HP, with pressure switch and transducer control. The AutoDRIVE is American made and housed in a NEMA 3R steel enclosure rated for outdoor use.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background:#E1E3E6;border-left:3px solid #B8BDC4;padding:8px 14px;font-size:11.5px;color:#4A4A4F;margin-top:14px;line-height:1.5\"\u003eGenuine A.Y. McDonald equipment, factory-new in original packaging — sold and supported by Watermain Supply, an independent industrial supplier. Watermain Supply is an Authorized Stocking A.Y. McDonald and Baker Water Systems Distributor.\u003c\/div\u003e\n\u003cdiv style=\"background:#fff;border-left:5px solid #B3122A;padding:15px 18px;margin-top:12px\"\u003e\n\u003cdiv style=\"font-family:Arial Black,Arial,sans-serif;font-size:15px;color:#B3122A;text-transform:uppercase;letter-spacing:1px;margin-bottom:6px\"\u003eA.Y. McDonald Warranty\u003c\/div\u003e\n\u003cp style=\"margin:0;font-size:13.5px;color:#4A4A4F;line-height:1.55\"\u003ePump and motor: covered for \u003cstrong\u003e5 years from the date of manufacture in potable water applications\u003c\/strong\u003e, and 3 years from the date of manufacture in other applications, under A.Y. McDonald’s published terms for Baker submersible motors and assembled submersible pumps. The AutoDRIVE and pressure control fall under A.Y. McDonald’s standard limited warranty: 2 years from the date of manufacture or 1 year from installation, whichever comes first.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eRoom to Grow\u003c\/div\u003e\n\u003cdiv class=\"gs-lead\"\u003e\n\u003cp\u003eOne pump and one drive per well. Need more head later? Step up in horsepower within the M - 25 GPM class; the drive model changes with the motor (see the Models table). Need more flow? Move to a higher flow class of the AutoPAC 23000 Series; every class uses the same 1 1\/4 in NPT discharge.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eModels \u0026amp; Ratings (60 Hz)\u003c\/div\u003e\n\u003cdiv class=\"gs-lead\"\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003cth\u003ePart No.\u003c\/th\u003e\n\u003cth\u003eHP\u003c\/th\u003e\n\u003cth\u003eMotor\u003c\/th\u003e\n\u003cth\u003eControl\u003c\/th\u003e\n\u003cth\u003eAutoDRIVE\u003c\/th\u003e\n\u003cth\u003eHead at 25 GPM\u003c\/th\u003e\n\u003cth\u003eShut-off Head\u003c\/th\u003e\n\u003cth\u003eWeight\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e23050M2-APS\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6630-588\u003c\/td\u003e\n\u003ctd\u003e1\/2\u003c\/td\u003e\n\u003ctd\u003e230V 1Ph 2-Wire\u003c\/td\u003e\n\u003ctd\u003ePressure Switch\u003c\/td\u003e\n\u003ctd\u003eSD1-2HP2PS\u003c\/td\u003e\n\u003ctd\u003e64 ft\u003c\/td\u003e\n\u003ctd\u003e122 ft\u003c\/td\u003e\n\u003ctd\u003e41 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e23050M2-APT\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6630-582\u003c\/td\u003e\n\u003ctd\u003e1\/2\u003c\/td\u003e\n\u003ctd\u003e230V 1Ph 2-Wire\u003c\/td\u003e\n\u003ctd\u003eTransducer\u003c\/td\u003e\n\u003ctd\u003eSD1-2HP2\u003c\/td\u003e\n\u003ctd\u003e64 ft\u003c\/td\u003e\n\u003ctd\u003e122 ft\u003c\/td\u003e\n\u003ctd\u003e41 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e23050M3-APS\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6630-636\u003c\/td\u003e\n\u003ctd\u003e1\/2\u003c\/td\u003e\n\u003ctd\u003e230V 1Ph 3-Wire\u003c\/td\u003e\n\u003ctd\u003ePressure Switch\u003c\/td\u003e\n\u003ctd\u003eSD1-2HP2PS\u003c\/td\u003e\n\u003ctd\u003e64 ft\u003c\/td\u003e\n\u003ctd\u003e122 ft\u003c\/td\u003e\n\u003ctd\u003e39 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e23050M3-APT\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6630-630\u003c\/td\u003e\n\u003ctd\u003e1\/2\u003c\/td\u003e\n\u003ctd\u003e230V 1Ph 3-Wire\u003c\/td\u003e\n\u003ctd\u003eTransducer\u003c\/td\u003e\n\u003ctd\u003eSD1-2HP2\u003c\/td\u003e\n\u003ctd\u003e64 ft\u003c\/td\u003e\n\u003ctd\u003e122 ft\u003c\/td\u003e\n\u003ctd\u003e39 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e23075M2-APS\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6630-600\u003c\/td\u003e\n\u003ctd\u003e3\/4\u003c\/td\u003e\n\u003ctd\u003e230V 1Ph 2-Wire\u003c\/td\u003e\n\u003ctd\u003ePressure Switch\u003c\/td\u003e\n\u003ctd\u003eSD1-2HP2PS\u003c\/td\u003e\n\u003ctd\u003e85 ft\u003c\/td\u003e\n\u003ctd\u003e152 ft\u003c\/td\u003e\n\u003ctd\u003e43 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e23075M2-APT\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6630-594\u003c\/td\u003e\n\u003ctd\u003e3\/4\u003c\/td\u003e\n\u003ctd\u003e230V 1Ph 2-Wire\u003c\/td\u003e\n\u003ctd\u003eTransducer\u003c\/td\u003e\n\u003ctd\u003eSD1-2HP2\u003c\/td\u003e\n\u003ctd\u003e85 ft\u003c\/td\u003e\n\u003ctd\u003e152 ft\u003c\/td\u003e\n\u003ctd\u003e43 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e23075M3-APS\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6630-648\u003c\/td\u003e\n\u003ctd\u003e3\/4\u003c\/td\u003e\n\u003ctd\u003e230V 1Ph 3-Wire\u003c\/td\u003e\n\u003ctd\u003ePressure Switch\u003c\/td\u003e\n\u003ctd\u003eSD1-2HP2PS\u003c\/td\u003e\n\u003ctd\u003e85 ft\u003c\/td\u003e\n\u003ctd\u003e152 ft\u003c\/td\u003e\n\u003ctd\u003e40 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e23075M3-APT\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6630-642\u003c\/td\u003e\n\u003ctd\u003e3\/4\u003c\/td\u003e\n\u003ctd\u003e230V 1Ph 3-Wire\u003c\/td\u003e\n\u003ctd\u003eTransducer\u003c\/td\u003e\n\u003ctd\u003eSD1-2HP2\u003c\/td\u003e\n\u003ctd\u003e85 ft\u003c\/td\u003e\n\u003ctd\u003e152 ft\u003c\/td\u003e\n\u003ctd\u003e40 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e23100M2-APS\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6630-612\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003ctd\u003e230V 1Ph 2-Wire\u003c\/td\u003e\n\u003ctd\u003ePressure Switch\u003c\/td\u003e\n\u003ctd\u003eSD1-2HP2PS\u003c\/td\u003e\n\u003ctd\u003e127 ft\u003c\/td\u003e\n\u003ctd\u003e219 ft\u003c\/td\u003e\n\u003ctd\u003e49 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e23100M2-APT\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6630-606\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003ctd\u003e230V 1Ph 2-Wire\u003c\/td\u003e\n\u003ctd\u003eTransducer\u003c\/td\u003e\n\u003ctd\u003eSD1-2HP2\u003c\/td\u003e\n\u003ctd\u003e127 ft\u003c\/td\u003e\n\u003ctd\u003e219 ft\u003c\/td\u003e\n\u003ctd\u003e49 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e23100M3-APS\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6630-660\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003ctd\u003e230V 1Ph 3-Wire\u003c\/td\u003e\n\u003ctd\u003ePressure Switch\u003c\/td\u003e\n\u003ctd\u003eSD1-2HP2PS\u003c\/td\u003e\n\u003ctd\u003e127 ft\u003c\/td\u003e\n\u003ctd\u003e219 ft\u003c\/td\u003e\n\u003ctd\u003e48 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e23100M3-APT\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6630-654\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003ctd\u003e230V 1Ph 3-Wire\u003c\/td\u003e\n\u003ctd\u003eTransducer\u003c\/td\u003e\n\u003ctd\u003eSD1-2HP2\u003c\/td\u003e\n\u003ctd\u003e127 ft\u003c\/td\u003e\n\u003ctd\u003e219 ft\u003c\/td\u003e\n\u003ctd\u003e48 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e23100M3Z-APT\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6630-887\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003ctd\u003e230V 3Ph\u003c\/td\u003e\n\u003ctd\u003eTransducer\u003c\/td\u003e\n\u003ctd\u003eSD3-2HP2\u003c\/td\u003e\n\u003ctd\u003e127 ft\u003c\/td\u003e\n\u003ctd\u003e219 ft\u003c\/td\u003e\n\u003ctd\u003e50 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e23150M2-APS\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6630-624\u003c\/td\u003e\n\u003ctd\u003e1 1\/2\u003c\/td\u003e\n\u003ctd\u003e230V 1Ph 2-Wire\u003c\/td\u003e\n\u003ctd\u003ePressure Switch\u003c\/td\u003e\n\u003ctd\u003eSD1-2HP2PS\u003c\/td\u003e\n\u003ctd\u003e176 ft\u003c\/td\u003e\n\u003ctd\u003e282 ft\u003c\/td\u003e\n\u003ctd\u003e55 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e23150M2-APT\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6630-618\u003c\/td\u003e\n\u003ctd\u003e1 1\/2\u003c\/td\u003e\n\u003ctd\u003e230V 1Ph 2-Wire\u003c\/td\u003e\n\u003ctd\u003eTransducer\u003c\/td\u003e\n\u003ctd\u003eSD1-2HP2\u003c\/td\u003e\n\u003ctd\u003e176 ft\u003c\/td\u003e\n\u003ctd\u003e282 ft\u003c\/td\u003e\n\u003ctd\u003e55 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e23150M3-APS\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6630-672\u003c\/td\u003e\n\u003ctd\u003e1 1\/2\u003c\/td\u003e\n\u003ctd\u003e230V 1Ph 3-Wire\u003c\/td\u003e\n\u003ctd\u003ePressure Switch\u003c\/td\u003e\n\u003ctd\u003eSD1-2HP2PS\u003c\/td\u003e\n\u003ctd\u003e176 ft\u003c\/td\u003e\n\u003ctd\u003e282 ft\u003c\/td\u003e\n\u003ctd\u003e54 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e23150M3-APT\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6630-666\u003c\/td\u003e\n\u003ctd\u003e1 1\/2\u003c\/td\u003e\n\u003ctd\u003e230V 1Ph 3-Wire\u003c\/td\u003e\n\u003ctd\u003eTransducer\u003c\/td\u003e\n\u003ctd\u003eSD1-2HP2\u003c\/td\u003e\n\u003ctd\u003e176 ft\u003c\/td\u003e\n\u003ctd\u003e282 ft\u003c\/td\u003e\n\u003ctd\u003e54 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e23150M3Z-APT\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6630-854\u003c\/td\u003e\n\u003ctd\u003e1 1\/2\u003c\/td\u003e\n\u003ctd\u003e230V 3Ph\u003c\/td\u003e\n\u003ctd\u003eTransducer\u003c\/td\u003e\n\u003ctd\u003eSD3-2HP2\u003c\/td\u003e\n\u003ctd\u003e176 ft\u003c\/td\u003e\n\u003ctd\u003e282 ft\u003c\/td\u003e\n\u003ctd\u003e47 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e23200M3-APS\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6630-682\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e230V 1Ph 3-Wire\u003c\/td\u003e\n\u003ctd\u003ePressure Switch\u003c\/td\u003e\n\u003ctd\u003eSD1-2HP2PS\u003c\/td\u003e\n\u003ctd\u003e220 ft\u003c\/td\u003e\n\u003ctd\u003e374 ft\u003c\/td\u003e\n\u003ctd\u003e56 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e23200M3-APT\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6630-677\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e230V 1Ph 3-Wire\u003c\/td\u003e\n\u003ctd\u003eTransducer\u003c\/td\u003e\n\u003ctd\u003eSD1-2HP2\u003c\/td\u003e\n\u003ctd\u003e220 ft\u003c\/td\u003e\n\u003ctd\u003e374 ft\u003c\/td\u003e\n\u003ctd\u003e56 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e23200M3Z-APT\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6630-687\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e230V 3Ph\u003c\/td\u003e\n\u003ctd\u003eTransducer\u003c\/td\u003e\n\u003ctd\u003eSD3-2HP2\u003c\/td\u003e\n\u003ctd\u003e220 ft\u003c\/td\u003e\n\u003ctd\u003e374 ft\u003c\/td\u003e\n\u003ctd\u003e54 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e23300M3Z-APT\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6630-691\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003ctd\u003e230V 3Ph\u003c\/td\u003e\n\u003ctd\u003eTransducer\u003c\/td\u003e\n\u003ctd\u003eSD3-3HP2\u003c\/td\u003e\n\u003ctd\u003e303 ft\u003c\/td\u003e\n\u003ctd\u003e507 ft\u003c\/td\u003e\n\u003ctd\u003e65 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e23500M3Z-APT\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6630-695\u003c\/td\u003e\n\u003ctd\u003e5\u003c\/td\u003e\n\u003ctd\u003e230V 3Ph\u003c\/td\u003e\n\u003ctd\u003eTransducer\u003c\/td\u003e\n\u003ctd\u003eSD3-5HP2\u003c\/td\u003e\n\u003ctd\u003e480 ft\u003c\/td\u003e\n\u003ctd\u003e796 ft\u003c\/td\u003e\n\u003ctd\u003e80 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"font-size:12.5px;color:#9B9EA3;margin-top:8px;line-height:1.55\"\u003eHead at 25 GPM is read from the published AutoPAC curve (Pumps by Baker catalog (Sept 2025, rev 3\/26), p. 155), digitized and rounded down. Shut-off head as printed. Drive per the compatibility table on p. 141 (1 1\/2 HP three-phase builds use the SD3-2HP2). Sources: Pumps by Baker catalog (Sept 2025, rev 3\/26), pp. 141-143 and 155; Baker Pumps and Accessories price list, effective 7\/1\/2026.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eShared Specifications\u003c\/div\u003e\n\u003cdiv class=\"gs-lead\"\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eIncluded\u003c\/td\u003e\n\u003ctd\u003ePump end, Baker 4 in motor, AutoDRIVE drive, and pressure switch or transducer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDischarge\u003c\/td\u003e\n\u003ctd\u003e1 1\/4 in NPT (female)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCheck valve\u003c\/td\u003e\n\u003ctd\u003eBuilt in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply\u003c\/td\u003e\n\u003ctd\u003e230V single-phase, 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor\u003c\/td\u003e\n\u003ctd\u003eBaker 4 in submersible motor, matched to the pump end horsepower\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePump diameter\u003c\/td\u003e\n\u003ctd\u003e3 3\/4 in with cable guard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrive enclosure\u003c\/td\u003e\n\u003ctd\u003eNEMA Type 3R steel, 12.25 x 9.25 x 4.68 in, 13 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrive operating temperature\u003c\/td\u003e\n\u003ctd\u003e-4 to 122°F; SD3-5HP2 rated to 104°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrive efficiency\u003c\/td\u003e\n\u003ctd\u003e95%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApp connection\u003c\/td\u003e\n\u003ctd\u003eNone; set up on the drive display\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"font-size:12.5px;color:#9B9EA3;margin-top:8px;line-height:1.55\"\u003eSource: Pumps by Baker catalog (Sept 2025, rev 3\/26), pp. 131-133 and 141-143.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003ePerformance — Will It Do What You Need?\u003c\/div\u003e\n\u003cdiv class=\"gs-lead\"\u003e\n\u003cp\u003e\u003cstrong\u003eTotal head\u003c\/strong\u003e is everything the pump lifts against: the vertical lift from the pumping water level to the discharge, the pressure you set on the drive (2.31 ft for every PSI), and friction in the drop pipe. The drive slows the pump when demand falls, so the curve below is the most the pump delivers at full speed.\u003c\/p\u003e\n\u003cp style=\"margin-bottom:4px\"\u003e\u003cstrong\u003eTotal head in feet, by flow in GPM, at full speed\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eHP (stages)\u003c\/th\u003e\n\u003cth\u003e0\u003c\/th\u003e\n\u003cth\u003e5\u003c\/th\u003e\n\u003cth\u003e10\u003c\/th\u003e\n\u003cth\u003e15\u003c\/th\u003e\n\u003cth\u003e20\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003e25\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e30\u003c\/th\u003e\n\u003cth\u003e35\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e1\/2 HP (4)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e121\u003c\/td\u003e\n\u003ctd\u003e113\u003c\/td\u003e\n\u003ctd\u003e104\u003c\/td\u003e\n\u003ctd\u003e93\u003c\/td\u003e\n\u003ctd\u003e80\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e64\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e46\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e3\/4 HP (5)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e151\u003c\/td\u003e\n\u003ctd\u003e143\u003c\/td\u003e\n\u003ctd\u003e133\u003c\/td\u003e\n\u003ctd\u003e122\u003c\/td\u003e\n\u003ctd\u003e107\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e85\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e61\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e1 HP (7)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e221\u003c\/td\u003e\n\u003ctd\u003e210\u003c\/td\u003e\n\u003ctd\u003e192\u003c\/td\u003e\n\u003ctd\u003e172\u003c\/td\u003e\n\u003ctd\u003e150\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e127\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e97\u003c\/td\u003e\n\u003ctd\u003e54\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e1 1\/2 HP (9)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e281\u003c\/td\u003e\n\u003ctd\u003e267\u003c\/td\u003e\n\u003ctd\u003e250\u003c\/td\u003e\n\u003ctd\u003e228\u003c\/td\u003e\n\u003ctd\u003e204\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e176\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e140\u003c\/td\u003e\n\u003ctd\u003e84\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e2 HP (12)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e375\u003c\/td\u003e\n\u003ctd\u003e355\u003c\/td\u003e\n\u003ctd\u003e329\u003c\/td\u003e\n\u003ctd\u003e299\u003c\/td\u003e\n\u003ctd\u003e263\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e220\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e163\u003c\/td\u003e\n\u003ctd\u003e97\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e3 HP (16)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e515\u003c\/td\u003e\n\u003ctd\u003e486\u003c\/td\u003e\n\u003ctd\u003e452\u003c\/td\u003e\n\u003ctd\u003e410\u003c\/td\u003e\n\u003ctd\u003e362\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e303\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e226\u003c\/td\u003e\n\u003ctd\u003e136\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e5 HP (25)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e801\u003c\/td\u003e\n\u003ctd\u003e761\u003c\/td\u003e\n\u003ctd\u003e709\u003c\/td\u003e\n\u003ctd\u003e650\u003c\/td\u003e\n\u003ctd\u003e576\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e480\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e366\u003c\/td\u003e\n\u003ctd\u003e235\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"font-size:12.5px;color:#9B9EA3;margin-top:6px;line-height:1.55\"\u003eDigitized from the published AutoPAC curve in the Pumps by Baker catalog (Sept 2025, rev 3\/26), p. 155, and rounded down. Rated flow (25 GPM) in bold. Zero flow is the shut-off point, a ceiling rather than a working point; — marks flows past the end of that curve.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBest operating range:\u003c\/strong\u003e the published curve shades the most efficient operating range; the catalog prints no figures for it. The curve is in the image gallery.\u003c\/p\u003e\n\u003cdiv style=\"display:flex;flex-wrap:wrap;gap:10px;margin:22px 0 4px\"\u003e\n\u003ca href=\"\/pages\/submersible-well-pump-sizing-calculator\" style=\"flex:1 1 200px;text-align:center;display:block;background:#B3122A;color:#ffffff;font-family:Arial Black,Arial,sans-serif;font-size:12px;text-transform:uppercase;letter-spacing:1.2px;padding:11px 18px;text-decoration:none\"\u003eSubmersible Calculator\u003c\/a\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eBefore You Buy — The Limits That Decide the Fit\u003c\/div\u003e\n\u003cdiv class=\"gs-lead\"\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply\u003c\/td\u003e\n\u003ctd\u003e230V single-phase for every build, from a circuit breaker sized per the table below\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure transducer\u003c\/td\u003e\n\u003ctd\u003eMust be installed upright and vertical (manufacturer note)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrive location\u003c\/td\u003e\n\u003ctd\u003eNEMA 3R enclosure, outdoors or indoors; rated to 122°F (104°F for SD3-5HP2); derate above 5500 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor cooling\u003c\/td\u003e\n\u003ctd\u003e1.0 ft\/sec of water flow past the motor at 95°F; motor rated to 95°F water\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWell size\u003c\/td\u003e\n\u003ctd\u003e4 in casing and larger\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePairing\u003c\/td\u003e\n\u003ctd\u003eOne pump and one drive per well\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"margin:14px 0 4px\"\u003e\u003cstrong\u003eBreaker sizing by motor HP (manufacturer recommendation)\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSupply\u003c\/th\u003e\n\u003cth\u003eMotor HP\u003c\/th\u003e\n\u003cth\u003eInput Current\u003c\/th\u003e\n\u003cth\u003eFuse \/ Breaker\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e230V\u003c\/td\u003e\n\u003ctd\u003e1\/2\u003c\/td\u003e\n\u003ctd\u003e6 A\u003c\/td\u003e\n\u003ctd\u003e10 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e230V\u003c\/td\u003e\n\u003ctd\u003e3\/4\u003c\/td\u003e\n\u003ctd\u003e9 A\u003c\/td\u003e\n\u003ctd\u003e15 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e230V\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003ctd\u003e14 A\u003c\/td\u003e\n\u003ctd\u003e20 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e230V\u003c\/td\u003e\n\u003ctd\u003e1 1\/2\u003c\/td\u003e\n\u003ctd\u003e18 A\u003c\/td\u003e\n\u003ctd\u003e25 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e230V\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e28 A\u003c\/td\u003e\n\u003ctd\u003e35 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e230V\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e20 A\u003c\/td\u003e\n\u003ctd\u003e25 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e230V\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003ctd\u003e30 A\u003c\/td\u003e\n\u003ctd\u003e40 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e230V\u003c\/td\u003e\n\u003ctd\u003e5\u003c\/td\u003e\n\u003ctd\u003e42 A\u003c\/td\u003e\n\u003ctd\u003e55 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"font-size:12.5px;color:#9B9EA3;margin-top:8px;line-height:1.55\"\u003eSource: Pumps by Baker catalog (Sept 2025, rev 3\/26), p. 131.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eMaterials of Construction (Pump)\u003c\/div\u003e\n\u003cdiv class=\"gs-lead\"\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eDischarge\u003c\/td\u003e\n\u003ctd\u003e300 series stainless steel, easy-wrench design with built-in safety eye; threads into the shell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCheck valve\u003c\/td\u003e\n\u003ctd\u003eBaker Diamond Design, easy-out for service\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDischarge bearing\u003c\/td\u003e\n\u003ctd\u003eRubber around the stainless steel shaft; self-lubricating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiffusers\u003c\/td\u003e\n\u003ctd\u003ePolycarbonate, corrosion and abrasion resistant, built for sand handling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eImpellers\u003c\/td\u003e\n\u003ctd\u003eGlass bead acetal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShaft\u003c\/td\u003e\n\u003ctd\u003e7\/16 in 300 series stainless steel, hex drive, each one measured for straightness\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShell\u003c\/td\u003e\n\u003ctd\u003eHeavy stainless steel, threaded at both ends for field service\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable guard\u003c\/td\u003e\n\u003ctd\u003eStainless steel; angled top keeps the leads in place\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor bracket\u003c\/td\u003e\n\u003ctd\u003eStainless steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"font-size:12.5px;color:#9B9EA3;margin-top:8px;line-height:1.55\"\u003eSource: Pumps by Baker catalog (Sept 2025, rev 3\/26), pp. 51-52.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eService Parts\u003c\/div\u003e\n\u003cdiv class=\"gs-lead\"\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003ePart\u003c\/th\u003e\n\u003cth\u003ePart No.\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutoDRIVE pressure transducer with 10 ft wire\u003c\/td\u003e\n\u003ctd\u003e6619-028\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutoDRIVE pressure switch with wire\u003c\/td\u003e\n\u003ctd\u003e6619-029\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutoDRIVE keypad\u003c\/td\u003e\n\u003ctd\u003e6619-030\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"font-size:12.5px;color:#9B9EA3;margin-top:8px;line-height:1.55\"\u003eSource: Pumps by Baker catalog (Sept 2025, rev 3\/26), pp. 142-143.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"gs-contact\"\u003eFor engineering-led sizing and selection support or a factory submittal, email \u003ca href=\"mailto:sales@watermainsupply.com\"\u003esales@watermainsupply.com\u003c\/a\u003e or call \u003ca href=\"tel:18885104036\"\u003e1-888.510.4036\u003c\/a\u003e.\u003cbr\u003e© Watermain Supply — A division of E4 Industrial LLC\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch5\u003eData Sheet\u003c\/h5\u003e\n\u003cdiv class=\"gs\"\u003e\n\u003cdiv class=\"gs-dl\"\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0264\/1913\/4527\/files\/AutoPac_Guide.pdf?v=1772502299\" target=\"_blank\" rel=\"noopener\"\u003ePumps by Baker AutoPac Guide\u003c\/a\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch5\u003eVideos\u003c\/h5\u003e\n\u003cdiv class=\"gs\"\u003e\u003cdiv class=\"gs-sec\" style=\"margin-top:6px\"\u003e\n\u003cp style=\"font-size:13px;color:#9B9EA3\"\u003eProduct videos are being added to this listing. For a walkthrough in the meantime, email sales@watermainsupply.com.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003c!-- \/TABS --\u003e","brand":"A.Y. McDonald","offers":[{"title":"1\/2 HP - 4 in Motor \/ 230V 1Ph 2-Wire \/ Switch - 23050M2-APS - 64 ft at 25 GPM","offer_id":46602929766575,"sku":"6630-588","price":2009.79,"currency_code":"USD","in_stock":true},{"title":"1\/2 HP - 4 in Motor \/ 230V 1Ph 2-Wire \/ Transducer - 23050M2-APT - 64 ft at 25 GPM","offer_id":46602929897647,"sku":"6630-582","price":2188.69,"currency_code":"USD","in_stock":true},{"title":"1\/2 HP - 4 in Motor \/ 230V 1Ph 3-Wire \/ Switch - 23050M3-APS - 64 ft at 25 GPM","offer_id":46602930028719,"sku":"6630-636","price":1923.92,"currency_code":"USD","in_stock":true},{"title":"1\/2 HP - 4 in Motor \/ 230V 1Ph 3-Wire \/ Transducer - 23050M3-APT - 64 ft at 25 GPM","offer_id":46602930192559,"sku":"6630-630","price":2102.83,"currency_code":"USD","in_stock":true},{"title":"3\/4 HP - 4 in Motor \/ 230V 1Ph 2-Wire \/ Switch - 23075M2-APS - 85 ft at 25 GPM","offer_id":46602929799343,"sku":"6630-600","price":2209.64,"currency_code":"USD","in_stock":true},{"title":"3\/4 HP - 4 in Motor \/ 230V 1Ph 2-Wire \/ Transducer - 23075M2-APT - 85 ft at 25 GPM","offer_id":46602929930415,"sku":"6630-594","price":2388.03,"currency_code":"USD","in_stock":true},{"title":"3\/4 HP - 4 in Motor \/ 230V 1Ph 3-Wire \/ Switch - 23075M3-APS - 85 ft at 25 GPM","offer_id":46602930061487,"sku":"6630-648","price":2094.65,"currency_code":"USD","in_stock":true},{"title":"3\/4 HP - 4 in Motor \/ 230V 1Ph 3-Wire \/ Transducer - 23075M3-APT - 85 ft at 25 GPM","offer_id":46602930225327,"sku":"6630-642","price":2273.53,"currency_code":"USD","in_stock":true},{"title":"1 HP - 4 in Motor \/ 230V 1Ph 2-Wire \/ Switch - 23100M2-APS - 127 ft at 25 GPM","offer_id":46602929832111,"sku":"6630-612","price":2263.82,"currency_code":"USD","in_stock":true},{"title":"1 HP - 4 in Motor \/ 230V 1Ph 2-Wire \/ Transducer - 23100M2-APT - 127 ft at 25 GPM","offer_id":46602929963183,"sku":"6630-606","price":2441.7,"currency_code":"USD","in_stock":true},{"title":"1 HP - 4 in Motor \/ 230V 1Ph 3-Wire \/ Switch - 23100M3-APS - 127 ft at 25 GPM","offer_id":46602930094255,"sku":"6630-660","price":2122.24,"currency_code":"USD","in_stock":true},{"title":"1 HP - 4 in Motor \/ 230V 1Ph 3-Wire \/ Transducer - 23100M3-APT - 127 ft at 25 GPM","offer_id":46602930258095,"sku":"6630-654","price":2301.65,"currency_code":"USD","in_stock":true},{"title":"1 HP - 4 in Motor \/ 230V 3Ph \/ Transducer - 23100M3Z-APT - 127 ft at 25 GPM","offer_id":46602930356399,"sku":"6630-887","price":2568.45,"currency_code":"USD","in_stock":true},{"title":"1 1\/2 HP - 4 in Motor \/ 230V 1Ph 2-Wire \/ Switch - 23150M2-APS - 176 ft at 25 GPM","offer_id":46602929864879,"sku":"6630-624","price":2611.43,"currency_code":"USD","in_stock":true},{"title":"1 1\/2 HP - 4 in Motor \/ 230V 1Ph 2-Wire \/ Transducer - 23150M2-APT - 176 ft at 25 GPM","offer_id":46602929995951,"sku":"6630-618","price":2790.33,"currency_code":"USD","in_stock":true},{"title":"1 1\/2 HP - 4 in Motor \/ 230V 1Ph 3-Wire \/ Switch - 23150M3-APS - 176 ft at 25 GPM","offer_id":46602930127023,"sku":"6630-672","price":2427.94,"currency_code":"USD","in_stock":true},{"title":"1 1\/2 HP - 4 in Motor \/ 230V 1Ph 3-Wire \/ Transducer - 23150M3-APT - 176 ft at 25 GPM","offer_id":46602930290863,"sku":"6630-666","price":2606.32,"currency_code":"USD","in_stock":true},{"title":"1 1\/2 HP - 4 in Motor \/ 230V 3Ph \/ Transducer - 23150M3Z-APT - 176 ft at 25 GPM","offer_id":46602930389167,"sku":"6630-854","price":2827.59,"currency_code":"USD","in_stock":true},{"title":"2 HP - 4 in Motor \/ 230V 1Ph 3-Wire \/ Switch - 23200M3-APS - 220 ft at 25 GPM","offer_id":46602930159791,"sku":"6630-682","price":2673.28,"currency_code":"USD","in_stock":true},{"title":"2 HP - 4 in Motor \/ 230V 1Ph 3-Wire \/ Transducer - 23200M3-APT - 220 ft at 25 GPM","offer_id":46602930323631,"sku":"6630-677","price":2852.69,"currency_code":"USD","in_stock":true},{"title":"2 HP - 4 in Motor \/ 230V 3Ph \/ Transducer - 23200M3Z-APT - 220 ft at 25 GPM","offer_id":46602930421935,"sku":"6630-687","price":3069.91,"currency_code":"USD","in_stock":true},{"title":"3 HP - 4 in Motor \/ 230V 3Ph \/ Transducer - 23300M3Z-APT - 303 ft at 25 GPM","offer_id":46602930454703,"sku":"6630-691","price":3843.25,"currency_code":"USD","in_stock":true},{"title":"5 HP - 4 in Motor \/ 230V 3Ph \/ Transducer - 23500M3Z-APT - 480 ft at 25 GPM","offer_id":46602930487471,"sku":"6630-695","price":5316.42,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0264\/1913\/4527\/files\/AutoPac_20d7061b-51d8-4330-b3c2-321ee38530b1.png?v=1772502605"},{"product_id":"baker-autopac-j-5-gpm-24000-series","title":"A.Y. McDonald AutoPAC J - 5 GPM 24000 Constant Pressure Pump","description":"\u003c!-- TABS --\u003e\n\u003ch5\u003eDescription\u003c\/h5\u003e\n\u003cdiv class=\"gs\"\u003e\n\u003cdiv class=\"gs-head\"\u003e\n\u003cdiv class=\"gs-eyebrow\"\u003eA.Y. McDonald · Constant Pressure Pump System\u003c\/div\u003e\n\u003cdiv class=\"gs-title\"\u003eAutoPAC J - 5 GPM, 24000 Series\u003c\/div\u003e\n\u003cdiv class=\"gs-sub\"\u003eBaker stainless steel 4 in submersible pump, motor and AutoDRIVE constant pressure drive, 1\/2 to 1 1\/2 HP, 17 builds.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"gs-badges\"\u003e\n\u003cdiv class=\"gs-badge\" style=\"background:#B3122A;color:#FFFFFF;border-color:#B3122A\"\u003e217-508 ft at 5 GPM\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003e1\/2-1 1\/2 HP\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003e230V Single-Phase Supply\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003eAutoDRIVE Constant Pressure VFD\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003ePressure Switch or Transducer Control\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003e822 ft Max Head (Shut-off)\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003e1 1\/4 in NPT Discharge\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003eNEMA 3R Drive Enclosure\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003eDrinking Water ANSI\/NSF 61\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003e41-62 lb Weight\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background:#FFFFFF;border:1px solid #C7CBD1;border-top:3px solid #B3122A;padding:12px 16px 12px;margin:16px 0 4px;font-size:13.5px;line-height:1.55;color:#4A4A4F\"\u003e\n\u003cdiv style=\"font-family:Arial Black,Arial,sans-serif;font-size:11px;letter-spacing:1.2px;text-transform:uppercase;color:#B3122A;margin-bottom:8px\"\u003eWhat Ships and What It Needs to Run\u003c\/div\u003e\n\u003cp style=\"margin:0 0 6px\"\u003e\u003cstrong style=\"color:#B3122A\"\u003eIncluded:\u003c\/strong\u003e the pump end and Baker 4 in motor, assembled, with the AutoDRIVE constant pressure drive matched to the motor, and the pressure switch (APS models) or pressure transducer with 10 ft wire (APT models). The drive model for each build is in the Models table.\u003c\/p\u003e\n\u003cp style=\"margin:0 0 6px\"\u003e\u003cstrong style=\"color:#B3122A\"\u003ePower:\u003c\/strong\u003e 230V single-phase supply from a circuit breaker for every build; the three-phase builds take single-phase power and the drive makes three-phase for the motor. Breaker sizes are under Before You Buy.\u003c\/p\u003e\n\u003cp style=\"margin:0\"\u003e\u003cstrong style=\"color:#B3122A\"\u003eSized at install:\u003c\/strong\u003e drop cable, splice kit and the pressure relief valve shown in the manufacturer’s installation diagram.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eOverview\u003c\/div\u003e\n\u003cdiv class=\"gs-lead\"\u003e\n\u003cp\u003eThe AutoPAC is Baker’s constant pressure well package: a 24000 Series 4 in submersible pump, a Baker motor of the same horsepower, and the AutoDRIVE variable frequency drive. The drive holds a set pressure by changing the pump speed, which allows a smaller pressure tank and a quick, simple installation; setup takes 5 steps or less on the drive’s backlit display.\u003c\/p\u003e\n\u003cp\u003eThis listing is the \u003cstrong\u003eJ - 5 GPM\u003c\/strong\u003e class: 1\/2 to 1 1\/2 HP, with pressure switch and transducer control. The AutoDRIVE is American made and housed in a NEMA 3R steel enclosure rated for outdoor use.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background:#E1E3E6;border-left:3px solid #B8BDC4;padding:8px 14px;font-size:11.5px;color:#4A4A4F;margin-top:14px;line-height:1.5\"\u003eGenuine A.Y. McDonald equipment, factory-new in original packaging — sold and supported by Watermain Supply, an independent industrial supplier. Watermain Supply is an Authorized Stocking A.Y. McDonald and Baker Water Systems Distributor.\u003c\/div\u003e\n\u003cdiv style=\"background:#fff;border-left:5px solid #B3122A;padding:15px 18px;margin-top:12px\"\u003e\n\u003cdiv style=\"font-family:Arial Black,Arial,sans-serif;font-size:15px;color:#B3122A;text-transform:uppercase;letter-spacing:1px;margin-bottom:6px\"\u003eA.Y. McDonald Warranty\u003c\/div\u003e\n\u003cp style=\"margin:0;font-size:13.5px;color:#4A4A4F;line-height:1.55\"\u003ePump and motor: covered for \u003cstrong\u003e5 years from the date of manufacture in potable water applications\u003c\/strong\u003e, and 3 years from the date of manufacture in other applications, under A.Y. McDonald’s published terms for Baker submersible motors and assembled submersible pumps. The AutoDRIVE and pressure control fall under A.Y. McDonald’s standard limited warranty: 2 years from the date of manufacture or 1 year from installation, whichever comes first.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eRoom to Grow\u003c\/div\u003e\n\u003cdiv class=\"gs-lead\"\u003e\n\u003cp\u003eOne pump and one drive per well. Need more head later? Step up in horsepower within the J - 5 GPM class; the drive model changes with the motor (see the Models table). Need more flow? Move to a higher flow class of the AutoPAC 24000 Series; every class uses the same 1 1\/4 in NPT discharge.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eModels \u0026amp; Ratings (60 Hz)\u003c\/div\u003e\n\u003cdiv class=\"gs-lead\"\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003cth\u003ePart No.\u003c\/th\u003e\n\u003cth\u003eHP\u003c\/th\u003e\n\u003cth\u003eMotor\u003c\/th\u003e\n\u003cth\u003eControl\u003c\/th\u003e\n\u003cth\u003eAutoDRIVE\u003c\/th\u003e\n\u003cth\u003eHead at 5 GPM\u003c\/th\u003e\n\u003cth\u003eShut-off Head\u003c\/th\u003e\n\u003cth\u003eWeight\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e24050J2-APS\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6630-701\u003c\/td\u003e\n\u003ctd\u003e1\/2\u003c\/td\u003e\n\u003ctd\u003e230V 1Ph 2-Wire\u003c\/td\u003e\n\u003ctd\u003ePressure Switch\u003c\/td\u003e\n\u003ctd\u003eSD1-2HP2PS\u003c\/td\u003e\n\u003ctd\u003e217 ft\u003c\/td\u003e\n\u003ctd\u003e376 ft\u003c\/td\u003e\n\u003ctd\u003e43 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e24050J2-APT\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6630-696\u003c\/td\u003e\n\u003ctd\u003e1\/2\u003c\/td\u003e\n\u003ctd\u003e230V 1Ph 2-Wire\u003c\/td\u003e\n\u003ctd\u003eTransducer\u003c\/td\u003e\n\u003ctd\u003eSD1-2HP2\u003c\/td\u003e\n\u003ctd\u003e217 ft\u003c\/td\u003e\n\u003ctd\u003e376 ft\u003c\/td\u003e\n\u003ctd\u003e43 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e24050J3-APS\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6630-745\u003c\/td\u003e\n\u003ctd\u003e1\/2\u003c\/td\u003e\n\u003ctd\u003e230V 1Ph 3-Wire\u003c\/td\u003e\n\u003ctd\u003ePressure Switch\u003c\/td\u003e\n\u003ctd\u003eSD1-2HP2PS\u003c\/td\u003e\n\u003ctd\u003e217 ft\u003c\/td\u003e\n\u003ctd\u003e376 ft\u003c\/td\u003e\n\u003ctd\u003e41 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e24050J3-APT\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6630-740\u003c\/td\u003e\n\u003ctd\u003e1\/2\u003c\/td\u003e\n\u003ctd\u003e230V 1Ph 3-Wire\u003c\/td\u003e\n\u003ctd\u003eTransducer\u003c\/td\u003e\n\u003ctd\u003eSD1-2HP2\u003c\/td\u003e\n\u003ctd\u003e217 ft\u003c\/td\u003e\n\u003ctd\u003e376 ft\u003c\/td\u003e\n\u003ctd\u003e41 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e24075J2-APS\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6630-711\u003c\/td\u003e\n\u003ctd\u003e3\/4\u003c\/td\u003e\n\u003ctd\u003e230V 1Ph 2-Wire\u003c\/td\u003e\n\u003ctd\u003ePressure Switch\u003c\/td\u003e\n\u003ctd\u003eSD1-2HP2PS\u003c\/td\u003e\n\u003ctd\u003e287 ft\u003c\/td\u003e\n\u003ctd\u003e481 ft\u003c\/td\u003e\n\u003ctd\u003e46 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e24075J2-APT\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6630-706\u003c\/td\u003e\n\u003ctd\u003e3\/4\u003c\/td\u003e\n\u003ctd\u003e230V 1Ph 2-Wire\u003c\/td\u003e\n\u003ctd\u003eTransducer\u003c\/td\u003e\n\u003ctd\u003eSD1-2HP2\u003c\/td\u003e\n\u003ctd\u003e287 ft\u003c\/td\u003e\n\u003ctd\u003e481 ft\u003c\/td\u003e\n\u003ctd\u003e46 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e24075J3-APS\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6630-755\u003c\/td\u003e\n\u003ctd\u003e3\/4\u003c\/td\u003e\n\u003ctd\u003e230V 1Ph 3-Wire\u003c\/td\u003e\n\u003ctd\u003ePressure Switch\u003c\/td\u003e\n\u003ctd\u003eSD1-2HP2PS\u003c\/td\u003e\n\u003ctd\u003e287 ft\u003c\/td\u003e\n\u003ctd\u003e481 ft\u003c\/td\u003e\n\u003ctd\u003e46 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e24075J3-APT\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6630-750\u003c\/td\u003e\n\u003ctd\u003e3\/4\u003c\/td\u003e\n\u003ctd\u003e230V 1Ph 3-Wire\u003c\/td\u003e\n\u003ctd\u003eTransducer\u003c\/td\u003e\n\u003ctd\u003eSD1-2HP2\u003c\/td\u003e\n\u003ctd\u003e287 ft\u003c\/td\u003e\n\u003ctd\u003e481 ft\u003c\/td\u003e\n\u003ctd\u003e43 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e24100J2-APS\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6630-722\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003ctd\u003e230V 1Ph 2-Wire\u003c\/td\u003e\n\u003ctd\u003ePressure Switch\u003c\/td\u003e\n\u003ctd\u003eSD1-2HP2PS\u003c\/td\u003e\n\u003ctd\u003e382 ft\u003c\/td\u003e\n\u003ctd\u003e641 ft\u003c\/td\u003e\n\u003ctd\u003e53 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e24100J2-APT\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6630-716\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003ctd\u003e230V 1Ph 2-Wire\u003c\/td\u003e\n\u003ctd\u003eTransducer\u003c\/td\u003e\n\u003ctd\u003eSD1-2HP2\u003c\/td\u003e\n\u003ctd\u003e382 ft\u003c\/td\u003e\n\u003ctd\u003e641 ft\u003c\/td\u003e\n\u003ctd\u003e53 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e24100J3-APS\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6630-766\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003ctd\u003e230V 1Ph 3-Wire\u003c\/td\u003e\n\u003ctd\u003ePressure Switch\u003c\/td\u003e\n\u003ctd\u003eSD1-2HP2PS\u003c\/td\u003e\n\u003ctd\u003e382 ft\u003c\/td\u003e\n\u003ctd\u003e641 ft\u003c\/td\u003e\n\u003ctd\u003e52 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e24100J3-APT\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6630-760\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003ctd\u003e230V 1Ph 3-Wire\u003c\/td\u003e\n\u003ctd\u003eTransducer\u003c\/td\u003e\n\u003ctd\u003eSD1-2HP2\u003c\/td\u003e\n\u003ctd\u003e382 ft\u003c\/td\u003e\n\u003ctd\u003e641 ft\u003c\/td\u003e\n\u003ctd\u003e52 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e24150J2-APS\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6630-734\u003c\/td\u003e\n\u003ctd\u003e1 1\/2\u003c\/td\u003e\n\u003ctd\u003e230V 1Ph 2-Wire\u003c\/td\u003e\n\u003ctd\u003ePressure Switch\u003c\/td\u003e\n\u003ctd\u003eSD1-2HP2PS\u003c\/td\u003e\n\u003ctd\u003e508 ft\u003c\/td\u003e\n\u003ctd\u003e822 ft\u003c\/td\u003e\n\u003ctd\u003e62 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e24150J2-APT\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6630-728\u003c\/td\u003e\n\u003ctd\u003e1 1\/2\u003c\/td\u003e\n\u003ctd\u003e230V 1Ph 2-Wire\u003c\/td\u003e\n\u003ctd\u003eTransducer\u003c\/td\u003e\n\u003ctd\u003eSD1-2HP2\u003c\/td\u003e\n\u003ctd\u003e508 ft\u003c\/td\u003e\n\u003ctd\u003e822 ft\u003c\/td\u003e\n\u003ctd\u003e62 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e24150J3-APS\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6630-778\u003c\/td\u003e\n\u003ctd\u003e1 1\/2\u003c\/td\u003e\n\u003ctd\u003e230V 1Ph 3-Wire\u003c\/td\u003e\n\u003ctd\u003ePressure Switch\u003c\/td\u003e\n\u003ctd\u003eSD1-2HP2PS\u003c\/td\u003e\n\u003ctd\u003e508 ft\u003c\/td\u003e\n\u003ctd\u003e822 ft\u003c\/td\u003e\n\u003ctd\u003e61 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e24150J3-APT\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6630-772\u003c\/td\u003e\n\u003ctd\u003e1 1\/2\u003c\/td\u003e\n\u003ctd\u003e230V 1Ph 3-Wire\u003c\/td\u003e\n\u003ctd\u003eTransducer\u003c\/td\u003e\n\u003ctd\u003eSD1-2HP2\u003c\/td\u003e\n\u003ctd\u003e508 ft\u003c\/td\u003e\n\u003ctd\u003e822 ft\u003c\/td\u003e\n\u003ctd\u003e61 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e24150J3Z-APT\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6630-855\u003c\/td\u003e\n\u003ctd\u003e1 1\/2\u003c\/td\u003e\n\u003ctd\u003e230V 3Ph\u003c\/td\u003e\n\u003ctd\u003eTransducer\u003c\/td\u003e\n\u003ctd\u003eSD3-2HP2\u003c\/td\u003e\n\u003ctd\u003e508 ft\u003c\/td\u003e\n\u003ctd\u003e822 ft\u003c\/td\u003e\n\u003ctd\u003e54 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"font-size:12.5px;color:#9B9EA3;margin-top:8px;line-height:1.55\"\u003eHead at 5 GPM is read from the published AutoPAC curve (Pumps by Baker catalog (Sept 2025, rev 3\/26), p. 146), digitized and rounded down. Shut-off head as printed. Drive per the compatibility table on p. 141 (1 1\/2 HP three-phase builds use the SD3-2HP2). Sources: Pumps by Baker catalog (Sept 2025, rev 3\/26), pp. 141-143 and 146; Baker Pumps and Accessories price list, effective 7\/1\/2026.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eShared Specifications\u003c\/div\u003e\n\u003cdiv class=\"gs-lead\"\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eIncluded\u003c\/td\u003e\n\u003ctd\u003ePump end, Baker 4 in motor, AutoDRIVE drive, and pressure switch or transducer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDischarge\u003c\/td\u003e\n\u003ctd\u003e1 1\/4 in NPT (female)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCheck valve\u003c\/td\u003e\n\u003ctd\u003eBuilt in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply\u003c\/td\u003e\n\u003ctd\u003e230V single-phase, 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor\u003c\/td\u003e\n\u003ctd\u003eBaker 4 in submersible motor, matched to the pump end horsepower\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePump diameter\u003c\/td\u003e\n\u003ctd\u003e3 3\/4 in with cable guard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrive enclosure\u003c\/td\u003e\n\u003ctd\u003eNEMA Type 3R steel, 12.25 x 9.25 x 4.68 in, 13 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrive operating temperature\u003c\/td\u003e\n\u003ctd\u003e-4 to 122°F; SD3-5HP2 rated to 104°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrive efficiency\u003c\/td\u003e\n\u003ctd\u003e95%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertification (pump)\u003c\/td\u003e\n\u003ctd\u003eDrinking Water ANSI\/NSF 61\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApp connection\u003c\/td\u003e\n\u003ctd\u003eNone; set up on the drive display\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"font-size:12.5px;color:#9B9EA3;margin-top:8px;line-height:1.55\"\u003eSource: Pumps by Baker catalog (Sept 2025, rev 3\/26), pp. 131-133 and 141-143.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003ePerformance — Will It Do What You Need?\u003c\/div\u003e\n\u003cdiv class=\"gs-lead\"\u003e\n\u003cp\u003e\u003cstrong\u003eTotal head\u003c\/strong\u003e is everything the pump lifts against: the vertical lift from the pumping water level to the discharge, the pressure you set on the drive (2.31 ft for every PSI), and friction in the drop pipe. The drive slows the pump when demand falls, so the curve below is the most the pump delivers at full speed.\u003c\/p\u003e\n\u003cp style=\"margin-bottom:4px\"\u003e\u003cstrong\u003eTotal head in feet, by flow in GPM, at full speed\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eHP (stages)\u003c\/th\u003e\n\u003cth\u003e0\u003c\/th\u003e\n\u003cth\u003e1\u003c\/th\u003e\n\u003cth\u003e2\u003c\/th\u003e\n\u003cth\u003e3\u003c\/th\u003e\n\u003cth\u003e4\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003e5\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e6\u003c\/th\u003e\n\u003cth\u003e7\u003c\/th\u003e\n\u003cth\u003e8\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e1\/2 HP (12)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e379\u003c\/td\u003e\n\u003ctd\u003e355\u003c\/td\u003e\n\u003ctd\u003e328\u003c\/td\u003e\n\u003ctd\u003e295\u003c\/td\u003e\n\u003ctd\u003e258\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e217\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e171\u003c\/td\u003e\n\u003ctd\u003e120\u003c\/td\u003e\n\u003ctd\u003e65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e3\/4 HP (15)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e484\u003c\/td\u003e\n\u003ctd\u003e460\u003c\/td\u003e\n\u003ctd\u003e430\u003c\/td\u003e\n\u003ctd\u003e391\u003c\/td\u003e\n\u003ctd\u003e343\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e287\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e223\u003c\/td\u003e\n\u003ctd\u003e151\u003c\/td\u003e\n\u003ctd\u003e70\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e1 HP (20)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e642\u003c\/td\u003e\n\u003ctd\u003e612\u003c\/td\u003e\n\u003ctd\u003e571\u003c\/td\u003e\n\u003ctd\u003e519\u003c\/td\u003e\n\u003ctd\u003e456\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e382\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e296\u003c\/td\u003e\n\u003ctd\u003e200\u003c\/td\u003e\n\u003ctd\u003e92\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e1 1\/2 HP (26)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e823\u003c\/td\u003e\n\u003ctd\u003e790\u003c\/td\u003e\n\u003ctd\u003e743\u003c\/td\u003e\n\u003ctd\u003e680\u003c\/td\u003e\n\u003ctd\u003e602\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e508\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e398\u003c\/td\u003e\n\u003ctd\u003e272\u003c\/td\u003e\n\u003ctd\u003e131\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"font-size:12.5px;color:#9B9EA3;margin-top:6px;line-height:1.55\"\u003eDigitized from the published AutoPAC curve in the Pumps by Baker catalog (Sept 2025, rev 3\/26), p. 146, and rounded down. Rated flow (5 GPM) in bold. Zero flow is the shut-off point, a ceiling rather than a working point; — marks flows past the end of that curve.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBest operating range:\u003c\/strong\u003e the published curve shades the most efficient operating range; the catalog prints no figures for it. The curve is in the image gallery.\u003c\/p\u003e\n\u003cdiv style=\"display:flex;flex-wrap:wrap;gap:10px;margin:22px 0 4px\"\u003e\n\u003ca href=\"\/pages\/submersible-well-pump-sizing-calculator\" style=\"flex:1 1 200px;text-align:center;display:block;background:#B3122A;color:#ffffff;font-family:Arial Black,Arial,sans-serif;font-size:12px;text-transform:uppercase;letter-spacing:1.2px;padding:11px 18px;text-decoration:none\"\u003eSubmersible Calculator\u003c\/a\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eBefore You Buy — The Limits That Decide the Fit\u003c\/div\u003e\n\u003cdiv class=\"gs-lead\"\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply\u003c\/td\u003e\n\u003ctd\u003e230V single-phase for every build, from a circuit breaker sized per the table below\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure transducer\u003c\/td\u003e\n\u003ctd\u003eMust be installed upright and vertical (manufacturer note)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrive location\u003c\/td\u003e\n\u003ctd\u003eNEMA 3R enclosure, outdoors or indoors; rated to 122°F (104°F for SD3-5HP2); derate above 5500 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor cooling\u003c\/td\u003e\n\u003ctd\u003e1.0 ft\/sec of water flow past the motor at 95°F; motor rated to 95°F water\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWell size\u003c\/td\u003e\n\u003ctd\u003e4 in casing and larger\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePairing\u003c\/td\u003e\n\u003ctd\u003eOne pump and one drive per well\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"margin:14px 0 4px\"\u003e\u003cstrong\u003eBreaker sizing by motor HP (manufacturer recommendation)\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSupply\u003c\/th\u003e\n\u003cth\u003eMotor HP\u003c\/th\u003e\n\u003cth\u003eInput Current\u003c\/th\u003e\n\u003cth\u003eFuse \/ Breaker\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e230V\u003c\/td\u003e\n\u003ctd\u003e1\/2\u003c\/td\u003e\n\u003ctd\u003e6 A\u003c\/td\u003e\n\u003ctd\u003e10 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e230V\u003c\/td\u003e\n\u003ctd\u003e3\/4\u003c\/td\u003e\n\u003ctd\u003e9 A\u003c\/td\u003e\n\u003ctd\u003e15 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e230V\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003ctd\u003e14 A\u003c\/td\u003e\n\u003ctd\u003e20 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e230V\u003c\/td\u003e\n\u003ctd\u003e1 1\/2\u003c\/td\u003e\n\u003ctd\u003e18 A\u003c\/td\u003e\n\u003ctd\u003e25 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e230V\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e28 A\u003c\/td\u003e\n\u003ctd\u003e35 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e230V\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e20 A\u003c\/td\u003e\n\u003ctd\u003e25 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e230V\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003ctd\u003e30 A\u003c\/td\u003e\n\u003ctd\u003e40 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e230V\u003c\/td\u003e\n\u003ctd\u003e5\u003c\/td\u003e\n\u003ctd\u003e42 A\u003c\/td\u003e\n\u003ctd\u003e55 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"font-size:12.5px;color:#9B9EA3;margin-top:8px;line-height:1.55\"\u003eSource: Pumps by Baker catalog (Sept 2025, rev 3\/26), p. 131.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eMaterials of Construction (Pump)\u003c\/div\u003e\n\u003cdiv class=\"gs-lead\"\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eDischarge head\u003c\/td\u003e\n\u003ctd\u003eStainless steel 304, 1 1\/4 in NPT discharge\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor adapter\u003c\/td\u003e\n\u003ctd\u003eStainless steel 304, NEMA standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCheck valve\u003c\/td\u003e\n\u003ctd\u003eStainless steel 304\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExternal shell\u003c\/td\u003e\n\u003ctd\u003eStainless steel 304, polished\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eImpellers\u003c\/td\u003e\n\u003ctd\u003eNoryl\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiffusers\u003c\/td\u003e\n\u003ctd\u003ePolycarbonate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBearing\u003c\/td\u003e\n\u003ctd\u003ePolyacetal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShaft coupling\u003c\/td\u003e\n\u003ctd\u003eStainless steel 304, NEMA standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStrainer\u003c\/td\u003e\n\u003ctd\u003eThermoplastic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShaft\u003c\/td\u003e\n\u003ctd\u003eStainless steel 304\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable guard\u003c\/td\u003e\n\u003ctd\u003eStainless steel 304\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"font-size:12.5px;color:#9B9EA3;margin-top:8px;line-height:1.55\"\u003eSource: Pumps by Baker catalog (Sept 2025, rev 3\/26), pp. 65-66.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eService Parts\u003c\/div\u003e\n\u003cdiv class=\"gs-lead\"\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003ePart\u003c\/th\u003e\n\u003cth\u003ePart No.\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutoDRIVE pressure transducer with 10 ft wire\u003c\/td\u003e\n\u003ctd\u003e6619-028\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutoDRIVE pressure switch with wire\u003c\/td\u003e\n\u003ctd\u003e6619-029\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutoDRIVE keypad\u003c\/td\u003e\n\u003ctd\u003e6619-030\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"font-size:12.5px;color:#9B9EA3;margin-top:8px;line-height:1.55\"\u003eSource: Pumps by Baker catalog (Sept 2025, rev 3\/26), pp. 142-143.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"gs-contact\"\u003eFor engineering-led sizing and selection support or a factory submittal, email \u003ca href=\"mailto:sales@watermainsupply.com\"\u003esales@watermainsupply.com\u003c\/a\u003e or call \u003ca href=\"tel:18885104036\"\u003e1-888.510.4036\u003c\/a\u003e.\u003cbr\u003e© Watermain Supply — A division of E4 Industrial LLC\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch5\u003eData Sheet\u003c\/h5\u003e\n\u003cdiv class=\"gs\"\u003e\n\u003cdiv class=\"gs-dl\"\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0264\/1913\/4527\/files\/AutoPac_Guide.pdf?v=1772502299\" target=\"_blank\" rel=\"noopener\"\u003ePumps by Baker AutoPac Guide\u003c\/a\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch5\u003eVideos\u003c\/h5\u003e\n\u003cdiv class=\"gs\"\u003e\u003cdiv class=\"gs-sec\" style=\"margin-top:6px\"\u003e\n\u003cp style=\"font-size:13px;color:#9B9EA3\"\u003eProduct videos are being added to this listing. For a walkthrough in the meantime, email sales@watermainsupply.com.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003c!-- \/TABS --\u003e","brand":"A.Y. McDonald","offers":[{"title":"1\/2 HP - 4 in Motor \/ 230V 1Ph 2-Wire \/ Switch - 24050J2-APS - 217 ft at 5 GPM","offer_id":46602930520239,"sku":"6630-701","price":1968.39,"currency_code":"USD","in_stock":true},{"title":"1\/2 HP - 4 in Motor \/ 230V 1Ph 2-Wire \/ Transducer - 24050J2-APT - 217 ft at 5 GPM","offer_id":46602930651311,"sku":"6630-696","price":2146.27,"currency_code":"USD","in_stock":true},{"title":"1\/2 HP - 4 in Motor \/ 230V 1Ph 3-Wire \/ Switch - 24050J3-APS - 217 ft at 5 GPM","offer_id":46602930782383,"sku":"6630-745","price":1881.5,"currency_code":"USD","in_stock":true},{"title":"1\/2 HP - 4 in Motor \/ 230V 1Ph 3-Wire \/ Transducer - 24050J3-APT - 217 ft at 5 GPM","offer_id":46602930913455,"sku":"6630-740","price":2060.9,"currency_code":"USD","in_stock":true},{"title":"3\/4 HP - 4 in Motor \/ 230V 1Ph 2-Wire \/ Switch - 24075J2-APS - 287 ft at 5 GPM","offer_id":46602930553007,"sku":"6630-711","price":2221.4,"currency_code":"USD","in_stock":true},{"title":"3\/4 HP - 4 in Motor \/ 230V 1Ph 2-Wire \/ Transducer - 24075J2-APT - 287 ft at 5 GPM","offer_id":46602930684079,"sku":"6630-706","price":2400.81,"currency_code":"USD","in_stock":true},{"title":"3\/4 HP - 4 in Motor \/ 230V 1Ph 3-Wire \/ Switch - 24075J3-APS - 287 ft at 5 GPM","offer_id":46602930815151,"sku":"6630-755","price":2106.92,"currency_code":"USD","in_stock":true},{"title":"3\/4 HP - 4 in Motor \/ 230V 1Ph 3-Wire \/ Transducer - 24075J3-APT - 287 ft at 5 GPM","offer_id":46602930946223,"sku":"6630-750","price":2286.32,"currency_code":"USD","in_stock":true},{"title":"1 HP - 4 in Motor \/ 230V 1Ph 2-Wire \/ Switch - 24100J2-APS - 382 ft at 5 GPM","offer_id":46602930585775,"sku":"6630-722","price":2521.47,"currency_code":"USD","in_stock":true},{"title":"1 HP - 4 in Motor \/ 230V 1Ph 2-Wire \/ Transducer - 24100J2-APT - 382 ft at 5 GPM","offer_id":46602930716847,"sku":"6630-716","price":2700.38,"currency_code":"USD","in_stock":true},{"title":"1 HP - 4 in Motor \/ 230V 1Ph 3-Wire \/ Switch - 24100J3-APS - 382 ft at 5 GPM","offer_id":46602930847919,"sku":"6630-766","price":2380.41,"currency_code":"USD","in_stock":true},{"title":"1 HP - 4 in Motor \/ 230V 1Ph 3-Wire \/ Transducer - 24100J3-APT - 382 ft at 5 GPM","offer_id":46602930978991,"sku":"6630-760","price":2558.78,"currency_code":"USD","in_stock":true},{"title":"1 1\/2 HP - 4 in Motor \/ 230V 1Ph 2-Wire \/ Switch - 24150J2-APS - 508 ft at 5 GPM","offer_id":46602930618543,"sku":"6630-734","price":2719.28,"currency_code":"USD","in_stock":true},{"title":"1 1\/2 HP - 4 in Motor \/ 230V 1Ph 2-Wire \/ Transducer - 24150J2-APT - 508 ft at 5 GPM","offer_id":46602930749615,"sku":"6630-728","price":2897.67,"currency_code":"USD","in_stock":true},{"title":"1 1\/2 HP - 4 in Motor \/ 230V 1Ph 3-Wire \/ Switch - 24150J3-APS - 508 ft at 5 GPM","offer_id":46602930880687,"sku":"6630-778","price":2535.28,"currency_code":"USD","in_stock":true},{"title":"1 1\/2 HP - 4 in Motor \/ 230V 1Ph 3-Wire \/ Transducer - 24150J3-APT - 508 ft at 5 GPM","offer_id":46602931011759,"sku":"6630-772","price":2713.65,"currency_code":"USD","in_stock":true},{"title":"1 1\/2 HP - 4 in Motor \/ 230V 3Ph \/ Transducer - 24150J3Z-APT - 508 ft at 5 GPM","offer_id":46602931044527,"sku":"6630-855","price":2972.8,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0264\/1913\/4527\/files\/AutoPac_02a782e6-adce-4cd9-beda-77c238ed88bc.png?v=1772502607"},{"product_id":"baker-autopac-v-7-gpm-24000-series","title":"A.Y. McDonald AutoPAC V - 7 GPM 24000 Constant Pressure Pump","description":"\u003c!-- TABS --\u003e\n\u003ch5\u003eDescription\u003c\/h5\u003e\n\u003cdiv class=\"gs\"\u003e\n\u003cdiv class=\"gs-head\"\u003e\n\u003cdiv class=\"gs-eyebrow\"\u003eA.Y. McDonald · Constant Pressure Pump System\u003c\/div\u003e\n\u003cdiv class=\"gs-title\"\u003eAutoPAC V - 7 GPM, 24000 Series\u003c\/div\u003e\n\u003cdiv class=\"gs-sub\"\u003eBaker stainless steel 4 in submersible pump, motor and AutoDRIVE constant pressure drive, 1\/2 to 2 HP, 20 builds.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"gs-badges\"\u003e\n\u003cdiv class=\"gs-badge\" style=\"background:#B3122A;color:#FFFFFF;border-color:#B3122A\"\u003e210-605 ft at 7 GPM\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003e1\/2-2 HP\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003e230V Single-Phase Supply\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003eAutoDRIVE Constant Pressure VFD\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003ePressure Switch or Transducer Control\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003e807 ft Max Head (Shut-off)\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003e1 1\/4 in NPT Discharge\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003eNEMA 3R Drive Enclosure\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003eDrinking Water ANSI\/NSF 61\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003e40-61 lb Weight\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background:#FFFFFF;border:1px solid #C7CBD1;border-top:3px solid #B3122A;padding:12px 16px 12px;margin:16px 0 4px;font-size:13.5px;line-height:1.55;color:#4A4A4F\"\u003e\n\u003cdiv style=\"font-family:Arial Black,Arial,sans-serif;font-size:11px;letter-spacing:1.2px;text-transform:uppercase;color:#B3122A;margin-bottom:8px\"\u003eWhat Ships and What It Needs to Run\u003c\/div\u003e\n\u003cp style=\"margin:0 0 6px\"\u003e\u003cstrong style=\"color:#B3122A\"\u003eIncluded:\u003c\/strong\u003e the pump end and Baker 4 in motor, assembled, with the AutoDRIVE constant pressure drive matched to the motor, and the pressure switch (APS models) or pressure transducer with 10 ft wire (APT models). The drive model for each build is in the Models table.\u003c\/p\u003e\n\u003cp style=\"margin:0 0 6px\"\u003e\u003cstrong style=\"color:#B3122A\"\u003ePower:\u003c\/strong\u003e 230V single-phase supply from a circuit breaker for every build; the three-phase builds take single-phase power and the drive makes three-phase for the motor. Breaker sizes are under Before You Buy.\u003c\/p\u003e\n\u003cp style=\"margin:0\"\u003e\u003cstrong style=\"color:#B3122A\"\u003eSized at install:\u003c\/strong\u003e drop cable, splice kit and the pressure relief valve shown in the manufacturer’s installation diagram.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eOverview\u003c\/div\u003e\n\u003cdiv class=\"gs-lead\"\u003e\n\u003cp\u003eThe AutoPAC is Baker’s constant pressure well package: a 24000 Series 4 in submersible pump, a Baker motor of the same horsepower, and the AutoDRIVE variable frequency drive. The drive holds a set pressure by changing the pump speed, which allows a smaller pressure tank and a quick, simple installation; setup takes 5 steps or less on the drive’s backlit display.\u003c\/p\u003e\n\u003cp\u003eThis listing is the \u003cstrong\u003eV - 7 GPM\u003c\/strong\u003e class: 1\/2 to 2 HP, with pressure switch and transducer control. The AutoDRIVE is American made and housed in a NEMA 3R steel enclosure rated for outdoor use.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background:#E1E3E6;border-left:3px solid #B8BDC4;padding:8px 14px;font-size:11.5px;color:#4A4A4F;margin-top:14px;line-height:1.5\"\u003eGenuine A.Y. McDonald equipment, factory-new in original packaging — sold and supported by Watermain Supply, an independent industrial supplier. Watermain Supply is an Authorized Stocking A.Y. McDonald and Baker Water Systems Distributor.\u003c\/div\u003e\n\u003cdiv style=\"background:#fff;border-left:5px solid #B3122A;padding:15px 18px;margin-top:12px\"\u003e\n\u003cdiv style=\"font-family:Arial Black,Arial,sans-serif;font-size:15px;color:#B3122A;text-transform:uppercase;letter-spacing:1px;margin-bottom:6px\"\u003eA.Y. McDonald Warranty\u003c\/div\u003e\n\u003cp style=\"margin:0;font-size:13.5px;color:#4A4A4F;line-height:1.55\"\u003ePump and motor: covered for \u003cstrong\u003e5 years from the date of manufacture in potable water applications\u003c\/strong\u003e, and 3 years from the date of manufacture in other applications, under A.Y. McDonald’s published terms for Baker submersible motors and assembled submersible pumps. The AutoDRIVE and pressure control fall under A.Y. McDonald’s standard limited warranty: 2 years from the date of manufacture or 1 year from installation, whichever comes first.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eRoom to Grow\u003c\/div\u003e\n\u003cdiv class=\"gs-lead\"\u003e\n\u003cp\u003eOne pump and one drive per well. Need more head later? Step up in horsepower within the V - 7 GPM class; the drive model changes with the motor (see the Models table). Need more flow? Move to a higher flow class of the AutoPAC 24000 Series; every class uses the same 1 1\/4 in NPT discharge.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eModels \u0026amp; Ratings (60 Hz)\u003c\/div\u003e\n\u003cdiv class=\"gs-lead\"\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003cth\u003ePart No.\u003c\/th\u003e\n\u003cth\u003eHP\u003c\/th\u003e\n\u003cth\u003eMotor\u003c\/th\u003e\n\u003cth\u003eControl\u003c\/th\u003e\n\u003cth\u003eAutoDRIVE\u003c\/th\u003e\n\u003cth\u003eHead at 7 GPM\u003c\/th\u003e\n\u003cth\u003eShut-off Head\u003c\/th\u003e\n\u003cth\u003eWeight\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e24050V2-APS\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6630-702\u003c\/td\u003e\n\u003ctd\u003e1\/2\u003c\/td\u003e\n\u003ctd\u003e230V 1Ph 2-Wire\u003c\/td\u003e\n\u003ctd\u003ePressure Switch\u003c\/td\u003e\n\u003ctd\u003eSD1-2HP2PS\u003c\/td\u003e\n\u003ctd\u003e210 ft\u003c\/td\u003e\n\u003ctd\u003e303 ft\u003c\/td\u003e\n\u003ctd\u003e42 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e24050V2-APT\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6630-697\u003c\/td\u003e\n\u003ctd\u003e1\/2\u003c\/td\u003e\n\u003ctd\u003e230V 1Ph 2-Wire\u003c\/td\u003e\n\u003ctd\u003eTransducer\u003c\/td\u003e\n\u003ctd\u003eSD1-2HP2\u003c\/td\u003e\n\u003ctd\u003e210 ft\u003c\/td\u003e\n\u003ctd\u003e303 ft\u003c\/td\u003e\n\u003ctd\u003e42 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e24050V3-APS\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6630-746\u003c\/td\u003e\n\u003ctd\u003e1\/2\u003c\/td\u003e\n\u003ctd\u003e230V 1Ph 3-Wire\u003c\/td\u003e\n\u003ctd\u003ePressure Switch\u003c\/td\u003e\n\u003ctd\u003eSD1-2HP2PS\u003c\/td\u003e\n\u003ctd\u003e210 ft\u003c\/td\u003e\n\u003ctd\u003e303 ft\u003c\/td\u003e\n\u003ctd\u003e40 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e24050V3-APT\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6630-741\u003c\/td\u003e\n\u003ctd\u003e1\/2\u003c\/td\u003e\n\u003ctd\u003e230V 1Ph 3-Wire\u003c\/td\u003e\n\u003ctd\u003eTransducer\u003c\/td\u003e\n\u003ctd\u003eSD1-2HP2\u003c\/td\u003e\n\u003ctd\u003e210 ft\u003c\/td\u003e\n\u003ctd\u003e303 ft\u003c\/td\u003e\n\u003ctd\u003e40 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e24075V2-APS\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6630-712\u003c\/td\u003e\n\u003ctd\u003e3\/4\u003c\/td\u003e\n\u003ctd\u003e230V 1Ph 2-Wire\u003c\/td\u003e\n\u003ctd\u003ePressure Switch\u003c\/td\u003e\n\u003ctd\u003eSD1-2HP2PS\u003c\/td\u003e\n\u003ctd\u003e287 ft\u003c\/td\u003e\n\u003ctd\u003e398 ft\u003c\/td\u003e\n\u003ctd\u003e45 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e24075V2-APT\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6630-707\u003c\/td\u003e\n\u003ctd\u003e3\/4\u003c\/td\u003e\n\u003ctd\u003e230V 1Ph 2-Wire\u003c\/td\u003e\n\u003ctd\u003eTransducer\u003c\/td\u003e\n\u003ctd\u003eSD1-2HP2\u003c\/td\u003e\n\u003ctd\u003e287 ft\u003c\/td\u003e\n\u003ctd\u003e398 ft\u003c\/td\u003e\n\u003ctd\u003e45 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e24075V3-APS\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6630-756\u003c\/td\u003e\n\u003ctd\u003e3\/4\u003c\/td\u003e\n\u003ctd\u003e230V 1Ph 3-Wire\u003c\/td\u003e\n\u003ctd\u003ePressure Switch\u003c\/td\u003e\n\u003ctd\u003eSD1-2HP2PS\u003c\/td\u003e\n\u003ctd\u003e287 ft\u003c\/td\u003e\n\u003ctd\u003e398 ft\u003c\/td\u003e\n\u003ctd\u003e42 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e24075V3-APT\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6630-751\u003c\/td\u003e\n\u003ctd\u003e3\/4\u003c\/td\u003e\n\u003ctd\u003e230V 1Ph 3-Wire\u003c\/td\u003e\n\u003ctd\u003eTransducer\u003c\/td\u003e\n\u003ctd\u003eSD1-2HP2\u003c\/td\u003e\n\u003ctd\u003e287 ft\u003c\/td\u003e\n\u003ctd\u003e398 ft\u003c\/td\u003e\n\u003ctd\u003e42 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e24100V2-APS\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6630-723\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003ctd\u003e230V 1Ph 2-Wire\u003c\/td\u003e\n\u003ctd\u003ePressure Switch\u003c\/td\u003e\n\u003ctd\u003eSD1-2HP2PS\u003c\/td\u003e\n\u003ctd\u003e379 ft\u003c\/td\u003e\n\u003ctd\u003e522 ft\u003c\/td\u003e\n\u003ctd\u003e53 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e24100V2-APT\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6630-717\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003ctd\u003e230V 1Ph 2-Wire\u003c\/td\u003e\n\u003ctd\u003eTransducer\u003c\/td\u003e\n\u003ctd\u003eSD1-2HP2\u003c\/td\u003e\n\u003ctd\u003e379 ft\u003c\/td\u003e\n\u003ctd\u003e522 ft\u003c\/td\u003e\n\u003ctd\u003e53 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e24100V3-APS\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6630-767\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003ctd\u003e230V 1Ph 3-Wire\u003c\/td\u003e\n\u003ctd\u003ePressure Switch\u003c\/td\u003e\n\u003ctd\u003eSD1-2HP2PS\u003c\/td\u003e\n\u003ctd\u003e379 ft\u003c\/td\u003e\n\u003ctd\u003e522 ft\u003c\/td\u003e\n\u003ctd\u003e52 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e24100V3-APT\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6630-761\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003ctd\u003e230V 1Ph 3-Wire\u003c\/td\u003e\n\u003ctd\u003eTransducer\u003c\/td\u003e\n\u003ctd\u003eSD1-2HP2\u003c\/td\u003e\n\u003ctd\u003e379 ft\u003c\/td\u003e\n\u003ctd\u003e522 ft\u003c\/td\u003e\n\u003ctd\u003e52 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e24150V2-APS\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6630-735\u003c\/td\u003e\n\u003ctd\u003e1 1\/2\u003c\/td\u003e\n\u003ctd\u003e230V 1Ph 2-Wire\u003c\/td\u003e\n\u003ctd\u003ePressure Switch\u003c\/td\u003e\n\u003ctd\u003eSD1-2HP2PS\u003c\/td\u003e\n\u003ctd\u003e492 ft\u003c\/td\u003e\n\u003ctd\u003e675 ft\u003c\/td\u003e\n\u003ctd\u003e60 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e24150V2-APT\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6630-729\u003c\/td\u003e\n\u003ctd\u003e1 1\/2\u003c\/td\u003e\n\u003ctd\u003e230V 1Ph 2-Wire\u003c\/td\u003e\n\u003ctd\u003eTransducer\u003c\/td\u003e\n\u003ctd\u003eSD1-2HP2\u003c\/td\u003e\n\u003ctd\u003e492 ft\u003c\/td\u003e\n\u003ctd\u003e675 ft\u003c\/td\u003e\n\u003ctd\u003e60 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e24150V3-APS\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6630-779\u003c\/td\u003e\n\u003ctd\u003e1 1\/2\u003c\/td\u003e\n\u003ctd\u003e230V 1Ph 3-Wire\u003c\/td\u003e\n\u003ctd\u003ePressure Switch\u003c\/td\u003e\n\u003ctd\u003eSD1-2HP2PS\u003c\/td\u003e\n\u003ctd\u003e492 ft\u003c\/td\u003e\n\u003ctd\u003e675 ft\u003c\/td\u003e\n\u003ctd\u003e59 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e24150V3-APT\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6630-773\u003c\/td\u003e\n\u003ctd\u003e1 1\/2\u003c\/td\u003e\n\u003ctd\u003e230V 1Ph 3-Wire\u003c\/td\u003e\n\u003ctd\u003eTransducer\u003c\/td\u003e\n\u003ctd\u003eSD1-2HP2\u003c\/td\u003e\n\u003ctd\u003e492 ft\u003c\/td\u003e\n\u003ctd\u003e675 ft\u003c\/td\u003e\n\u003ctd\u003e59 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e24150V3Z-APT\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6630-856\u003c\/td\u003e\n\u003ctd\u003e1 1\/2\u003c\/td\u003e\n\u003ctd\u003e230V 3Ph\u003c\/td\u003e\n\u003ctd\u003eTransducer\u003c\/td\u003e\n\u003ctd\u003eSD3-2HP2\u003c\/td\u003e\n\u003ctd\u003e492 ft\u003c\/td\u003e\n\u003ctd\u003e675 ft\u003c\/td\u003e\n\u003ctd\u003e52 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e24200V3-APS\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6630-789\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e230V 1Ph 3-Wire\u003c\/td\u003e\n\u003ctd\u003ePressure Switch\u003c\/td\u003e\n\u003ctd\u003eSD1-2HP2PS\u003c\/td\u003e\n\u003ctd\u003e605 ft\u003c\/td\u003e\n\u003ctd\u003e807 ft\u003c\/td\u003e\n\u003ctd\u003e61 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e24200V3-APT\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6630-784\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e230V 1Ph 3-Wire\u003c\/td\u003e\n\u003ctd\u003eTransducer\u003c\/td\u003e\n\u003ctd\u003eSD1-2HP2\u003c\/td\u003e\n\u003ctd\u003e605 ft\u003c\/td\u003e\n\u003ctd\u003e807 ft\u003c\/td\u003e\n\u003ctd\u003e61 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e24200V3Z-APT\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6630-794\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e230V 3Ph\u003c\/td\u003e\n\u003ctd\u003eTransducer\u003c\/td\u003e\n\u003ctd\u003eSD3-2HP2\u003c\/td\u003e\n\u003ctd\u003e605 ft\u003c\/td\u003e\n\u003ctd\u003e807 ft\u003c\/td\u003e\n\u003ctd\u003e59 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"font-size:12.5px;color:#9B9EA3;margin-top:8px;line-height:1.55\"\u003eHead at 7 GPM is read from the published AutoPAC curve (Pumps by Baker catalog (Sept 2025, rev 3\/26), p. 148), digitized and rounded down. Shut-off head as printed. Drive per the compatibility table on p. 141 (1 1\/2 HP three-phase builds use the SD3-2HP2). Sources: Pumps by Baker catalog (Sept 2025, rev 3\/26), pp. 141-143 and 148; Baker Pumps and Accessories price list, effective 7\/1\/2026.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eShared Specifications\u003c\/div\u003e\n\u003cdiv class=\"gs-lead\"\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eIncluded\u003c\/td\u003e\n\u003ctd\u003ePump end, Baker 4 in motor, AutoDRIVE drive, and pressure switch or transducer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDischarge\u003c\/td\u003e\n\u003ctd\u003e1 1\/4 in NPT (female)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCheck valve\u003c\/td\u003e\n\u003ctd\u003eBuilt in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply\u003c\/td\u003e\n\u003ctd\u003e230V single-phase, 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor\u003c\/td\u003e\n\u003ctd\u003eBaker 4 in submersible motor, matched to the pump end horsepower\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePump diameter\u003c\/td\u003e\n\u003ctd\u003e3 3\/4 in with cable guard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrive enclosure\u003c\/td\u003e\n\u003ctd\u003eNEMA Type 3R steel, 12.25 x 9.25 x 4.68 in, 13 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrive operating temperature\u003c\/td\u003e\n\u003ctd\u003e-4 to 122°F; SD3-5HP2 rated to 104°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrive efficiency\u003c\/td\u003e\n\u003ctd\u003e95%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertification (pump)\u003c\/td\u003e\n\u003ctd\u003eDrinking Water ANSI\/NSF 61\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApp connection\u003c\/td\u003e\n\u003ctd\u003eNone; set up on the drive display\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"font-size:12.5px;color:#9B9EA3;margin-top:8px;line-height:1.55\"\u003eSource: Pumps by Baker catalog (Sept 2025, rev 3\/26), pp. 131-133 and 141-143.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003ePerformance — Will It Do What You Need?\u003c\/div\u003e\n\u003cdiv class=\"gs-lead\"\u003e\n\u003cp\u003e\u003cstrong\u003eTotal head\u003c\/strong\u003e is everything the pump lifts against: the vertical lift from the pumping water level to the discharge, the pressure you set on the drive (2.31 ft for every PSI), and friction in the drop pipe. The drive slows the pump when demand falls, so the curve below is the most the pump delivers at full speed.\u003c\/p\u003e\n\u003cp style=\"margin-bottom:4px\"\u003e\u003cstrong\u003eTotal head in feet, by flow in GPM, at full speed\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eHP (stages)\u003c\/th\u003e\n\u003cth\u003e0\u003c\/th\u003e\n\u003cth\u003e2\u003c\/th\u003e\n\u003cth\u003e4\u003c\/th\u003e\n\u003cth\u003e6\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003e7\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e8\u003c\/th\u003e\n\u003cth\u003e10\u003c\/th\u003e\n\u003cth\u003e12\u003c\/th\u003e\n\u003cth\u003e14\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e1\/2 HP (10)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e299\u003c\/td\u003e\n\u003ctd\u003e282\u003c\/td\u003e\n\u003ctd\u003e258\u003c\/td\u003e\n\u003ctd\u003e228\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e210\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e191\u003c\/td\u003e\n\u003ctd\u003e148\u003c\/td\u003e\n\u003ctd\u003e99\u003c\/td\u003e\n\u003ctd\u003e43\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e3\/4 HP (13)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e396\u003c\/td\u003e\n\u003ctd\u003e376\u003c\/td\u003e\n\u003ctd\u003e347\u003c\/td\u003e\n\u003ctd\u003e310\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e287\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e263\u003c\/td\u003e\n\u003ctd\u003e208\u003c\/td\u003e\n\u003ctd\u003e143\u003c\/td\u003e\n\u003ctd\u003e70\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e1 HP (17)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e520\u003c\/td\u003e\n\u003ctd\u003e495\u003c\/td\u003e\n\u003ctd\u003e458\u003c\/td\u003e\n\u003ctd\u003e409\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e379\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e347\u003c\/td\u003e\n\u003ctd\u003e272\u003c\/td\u003e\n\u003ctd\u003e186\u003c\/td\u003e\n\u003ctd\u003e87\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e1 1\/2 HP (22)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e674\u003c\/td\u003e\n\u003ctd\u003e643\u003c\/td\u003e\n\u003ctd\u003e595\u003c\/td\u003e\n\u003ctd\u003e530\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e492\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e450\u003c\/td\u003e\n\u003ctd\u003e354\u003c\/td\u003e\n\u003ctd\u003e242\u003c\/td\u003e\n\u003ctd\u003e114\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e2 HP (27)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e809\u003c\/td\u003e\n\u003ctd\u003e779\u003c\/td\u003e\n\u003ctd\u003e727\u003c\/td\u003e\n\u003ctd\u003e651\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e605\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e554\u003c\/td\u003e\n\u003ctd\u003e436\u003c\/td\u003e\n\u003ctd\u003e298\u003c\/td\u003e\n\u003ctd\u003e141\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"font-size:12.5px;color:#9B9EA3;margin-top:6px;line-height:1.55\"\u003eDigitized from the published AutoPAC curve in the Pumps by Baker catalog (Sept 2025, rev 3\/26), p. 148, and rounded down. Rated flow (7 GPM) in bold. Zero flow is the shut-off point, a ceiling rather than a working point; — marks flows past the end of that curve.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBest operating range:\u003c\/strong\u003e the published curve shades the most efficient operating range; the catalog prints no figures for it. The curve is in the image gallery.\u003c\/p\u003e\n\u003cdiv style=\"display:flex;flex-wrap:wrap;gap:10px;margin:22px 0 4px\"\u003e\n\u003ca href=\"\/pages\/submersible-well-pump-sizing-calculator\" style=\"flex:1 1 200px;text-align:center;display:block;background:#B3122A;color:#ffffff;font-family:Arial Black,Arial,sans-serif;font-size:12px;text-transform:uppercase;letter-spacing:1.2px;padding:11px 18px;text-decoration:none\"\u003eSubmersible Calculator\u003c\/a\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eBefore You Buy — The Limits That Decide the Fit\u003c\/div\u003e\n\u003cdiv class=\"gs-lead\"\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply\u003c\/td\u003e\n\u003ctd\u003e230V single-phase for every build, from a circuit breaker sized per the table below\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure transducer\u003c\/td\u003e\n\u003ctd\u003eMust be installed upright and vertical (manufacturer note)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrive location\u003c\/td\u003e\n\u003ctd\u003eNEMA 3R enclosure, outdoors or indoors; rated to 122°F (104°F for SD3-5HP2); derate above 5500 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor cooling\u003c\/td\u003e\n\u003ctd\u003e1.0 ft\/sec of water flow past the motor at 95°F; motor rated to 95°F water\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWell size\u003c\/td\u003e\n\u003ctd\u003e4 in casing and larger\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePairing\u003c\/td\u003e\n\u003ctd\u003eOne pump and one drive per well\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"margin:14px 0 4px\"\u003e\u003cstrong\u003eBreaker sizing by motor HP (manufacturer recommendation)\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSupply\u003c\/th\u003e\n\u003cth\u003eMotor HP\u003c\/th\u003e\n\u003cth\u003eInput Current\u003c\/th\u003e\n\u003cth\u003eFuse \/ Breaker\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e230V\u003c\/td\u003e\n\u003ctd\u003e1\/2\u003c\/td\u003e\n\u003ctd\u003e6 A\u003c\/td\u003e\n\u003ctd\u003e10 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e230V\u003c\/td\u003e\n\u003ctd\u003e3\/4\u003c\/td\u003e\n\u003ctd\u003e9 A\u003c\/td\u003e\n\u003ctd\u003e15 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e230V\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003ctd\u003e14 A\u003c\/td\u003e\n\u003ctd\u003e20 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e230V\u003c\/td\u003e\n\u003ctd\u003e1 1\/2\u003c\/td\u003e\n\u003ctd\u003e18 A\u003c\/td\u003e\n\u003ctd\u003e25 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e230V\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e28 A\u003c\/td\u003e\n\u003ctd\u003e35 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e230V\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e20 A\u003c\/td\u003e\n\u003ctd\u003e25 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e230V\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003ctd\u003e30 A\u003c\/td\u003e\n\u003ctd\u003e40 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e230V\u003c\/td\u003e\n\u003ctd\u003e5\u003c\/td\u003e\n\u003ctd\u003e42 A\u003c\/td\u003e\n\u003ctd\u003e55 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"font-size:12.5px;color:#9B9EA3;margin-top:8px;line-height:1.55\"\u003eSource: Pumps by Baker catalog (Sept 2025, rev 3\/26), p. 131.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eMaterials of Construction (Pump)\u003c\/div\u003e\n\u003cdiv class=\"gs-lead\"\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eDischarge head\u003c\/td\u003e\n\u003ctd\u003eStainless steel 304, 1 1\/4 in NPT discharge\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor adapter\u003c\/td\u003e\n\u003ctd\u003eStainless steel 304, NEMA standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCheck valve\u003c\/td\u003e\n\u003ctd\u003eStainless steel 304\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExternal shell\u003c\/td\u003e\n\u003ctd\u003eStainless steel 304, polished\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eImpellers\u003c\/td\u003e\n\u003ctd\u003eNoryl\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiffusers\u003c\/td\u003e\n\u003ctd\u003ePolycarbonate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBearing\u003c\/td\u003e\n\u003ctd\u003ePolyacetal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShaft coupling\u003c\/td\u003e\n\u003ctd\u003eStainless steel 304, NEMA standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStrainer\u003c\/td\u003e\n\u003ctd\u003eThermoplastic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShaft\u003c\/td\u003e\n\u003ctd\u003eStainless steel 304\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable guard\u003c\/td\u003e\n\u003ctd\u003eStainless steel 304\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"font-size:12.5px;color:#9B9EA3;margin-top:8px;line-height:1.55\"\u003eSource: Pumps by Baker catalog (Sept 2025, rev 3\/26), pp. 65-66.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eService Parts\u003c\/div\u003e\n\u003cdiv class=\"gs-lead\"\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003ePart\u003c\/th\u003e\n\u003cth\u003ePart No.\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutoDRIVE pressure transducer with 10 ft wire\u003c\/td\u003e\n\u003ctd\u003e6619-028\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutoDRIVE pressure switch with wire\u003c\/td\u003e\n\u003ctd\u003e6619-029\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutoDRIVE keypad\u003c\/td\u003e\n\u003ctd\u003e6619-030\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"font-size:12.5px;color:#9B9EA3;margin-top:8px;line-height:1.55\"\u003eSource: Pumps by Baker catalog (Sept 2025, rev 3\/26), pp. 142-143.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"gs-contact\"\u003eFor engineering-led sizing and selection support or a factory submittal, email \u003ca href=\"mailto:sales@watermainsupply.com\"\u003esales@watermainsupply.com\u003c\/a\u003e or call \u003ca href=\"tel:18885104036\"\u003e1-888.510.4036\u003c\/a\u003e.\u003cbr\u003e© Watermain Supply — A division of E4 Industrial LLC\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch5\u003eData Sheet\u003c\/h5\u003e\n\u003cdiv class=\"gs\"\u003e\n\u003cdiv class=\"gs-dl\"\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0264\/1913\/4527\/files\/AutoPac_Guide.pdf?v=1772502299\" target=\"_blank\" rel=\"noopener\"\u003ePumps by Baker AutoPac Guide\u003c\/a\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch5\u003eVideos\u003c\/h5\u003e\n\u003cdiv class=\"gs\"\u003e\u003cdiv class=\"gs-sec\" style=\"margin-top:6px\"\u003e\n\u003cp style=\"font-size:13px;color:#9B9EA3\"\u003eProduct videos are being added to this listing. For a walkthrough in the meantime, email sales@watermainsupply.com.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003c!-- \/TABS --\u003e","brand":"A.Y. McDonald","offers":[{"title":"1\/2 HP - 4 in Motor \/ 230V 1Ph 2-Wire \/ Switch - 24050V2-APS - 210 ft at 7 GPM","offer_id":46602931077295,"sku":"6630-702","price":1855.94,"currency_code":"USD","in_stock":true},{"title":"1\/2 HP - 4 in Motor \/ 230V 1Ph 2-Wire \/ Transducer - 24050V2-APT - 210 ft at 7 GPM","offer_id":46602931208367,"sku":"6630-697","price":2034.84,"currency_code":"USD","in_stock":true},{"title":"1\/2 HP - 4 in Motor \/ 230V 1Ph 3-Wire \/ Switch - 24050V3-APS - 210 ft at 7 GPM","offer_id":46602931339439,"sku":"6630-746","price":1770.59,"currency_code":"USD","in_stock":true},{"title":"1\/2 HP - 4 in Motor \/ 230V 1Ph 3-Wire \/ Transducer - 24050V3-APT - 210 ft at 7 GPM","offer_id":46602931503279,"sku":"6630-741","price":1948.98,"currency_code":"USD","in_stock":true},{"title":"3\/4 HP - 4 in Motor \/ 230V 1Ph 2-Wire \/ Switch - 24075V2-APS - 287 ft at 7 GPM","offer_id":46602931110063,"sku":"6630-712","price":2138.09,"currency_code":"USD","in_stock":true},{"title":"3\/4 HP - 4 in Motor \/ 230V 1Ph 2-Wire \/ Transducer - 24075V2-APT - 287 ft at 7 GPM","offer_id":46602931241135,"sku":"6630-707","price":2316.47,"currency_code":"USD","in_stock":true},{"title":"3\/4 HP - 4 in Motor \/ 230V 1Ph 3-Wire \/ Switch - 24075V3-APS - 287 ft at 7 GPM","offer_id":46602931372207,"sku":"6630-756","price":2023.08,"currency_code":"USD","in_stock":true},{"title":"3\/4 HP - 4 in Motor \/ 230V 1Ph 3-Wire \/ Transducer - 24075V3-APT - 287 ft at 7 GPM","offer_id":46602931536047,"sku":"6630-751","price":2201.47,"currency_code":"USD","in_stock":true},{"title":"1 HP - 4 in Motor \/ 230V 1Ph 2-Wire \/ Switch - 24100V2-APS - 379 ft at 7 GPM","offer_id":46602931142831,"sku":"6630-723","price":2328.78,"currency_code":"USD","in_stock":true},{"title":"1 HP - 4 in Motor \/ 230V 1Ph 2-Wire \/ Transducer - 24100V2-APT - 379 ft at 7 GPM","offer_id":46602931273903,"sku":"6630-717","price":2507.67,"currency_code":"USD","in_stock":true},{"title":"1 HP - 4 in Motor \/ 230V 1Ph 3-Wire \/ Switch - 24100V3-APS - 379 ft at 7 GPM","offer_id":46602931404975,"sku":"6630-767","price":2188.74,"currency_code":"USD","in_stock":true},{"title":"1 HP - 4 in Motor \/ 230V 1Ph 3-Wire \/ Transducer - 24100V3-APT - 379 ft at 7 GPM","offer_id":46602931568815,"sku":"6630-761","price":2366.6,"currency_code":"USD","in_stock":true},{"title":"1 1\/2 HP - 4 in Motor \/ 230V 1Ph 2-Wire \/ Switch - 24150V2-APS - 492 ft at 7 GPM","offer_id":46602931175599,"sku":"6630-735","price":2611.43,"currency_code":"USD","in_stock":true},{"title":"1 1\/2 HP - 4 in Motor \/ 230V 1Ph 2-Wire \/ Transducer - 24150V2-APT - 492 ft at 7 GPM","offer_id":46602931306671,"sku":"6630-729","price":2790.33,"currency_code":"USD","in_stock":true},{"title":"1 1\/2 HP - 4 in Motor \/ 230V 1Ph 3-Wire \/ Switch - 24150V3-APS - 492 ft at 7 GPM","offer_id":46602931437743,"sku":"6630-779","price":2427.94,"currency_code":"USD","in_stock":true},{"title":"1 1\/2 HP - 4 in Motor \/ 230V 1Ph 3-Wire \/ Transducer - 24150V3-APT - 492 ft at 7 GPM","offer_id":46602931601583,"sku":"6630-773","price":2606.32,"currency_code":"USD","in_stock":true},{"title":"1 1\/2 HP - 4 in Motor \/ 230V 3Ph \/ Transducer - 24150V3Z-APT - 492 ft at 7 GPM","offer_id":46602931667119,"sku":"6630-856","price":2864.44,"currency_code":"USD","in_stock":true},{"title":"2 HP - 4 in Motor \/ 230V 1Ph 3-Wire \/ Switch - 24200V3-APS - 605 ft at 7 GPM","offer_id":46602931470511,"sku":"6630-789","price":2749.44,"currency_code":"USD","in_stock":true},{"title":"2 HP - 4 in Motor \/ 230V 1Ph 3-Wire \/ Transducer - 24200V3-APT - 605 ft at 7 GPM","offer_id":46602931634351,"sku":"6630-784","price":2928.33,"currency_code":"USD","in_stock":true},{"title":"2 HP - 4 in Motor \/ 230V 3Ph \/ Transducer - 24200V3Z-APT - 605 ft at 7 GPM","offer_id":46602931699887,"sku":"6630-794","price":3145.56,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0264\/1913\/4527\/files\/AutoPac_95b9ecff-7f2b-46e2-8fdf-d14e144afc3f.png?v=1772502608"},{"product_id":"baker-autopac-k-10-gpm-24000-series","title":"A.Y. McDonald AutoPAC K - 10 GPM 24000 Constant Pressure Pump","description":"\u003c!-- TABS --\u003e\n\u003ch5\u003eDescription\u003c\/h5\u003e\n\u003cdiv class=\"gs\"\u003e\n\u003cdiv class=\"gs-head\"\u003e\n\u003cdiv class=\"gs-eyebrow\"\u003eA.Y. McDonald · Constant Pressure Pump System\u003c\/div\u003e\n\u003cdiv class=\"gs-title\"\u003eAutoPAC K - 10 GPM, 24000 Series\u003c\/div\u003e\n\u003cdiv class=\"gs-sub\"\u003eBaker stainless steel 4 in submersible pump, motor and AutoDRIVE constant pressure drive, 1\/2 to 5 HP, 22 builds.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"gs-badges\"\u003e\n\u003cdiv class=\"gs-badge\" style=\"background:#B3122A;color:#FFFFFF;border-color:#B3122A\"\u003e160-994 ft at 10 GPM\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003e1\/2-5 HP\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003e230V Single-Phase Supply\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003eAutoDRIVE Constant Pressure VFD\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003ePressure Switch or Transducer Control\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003e1340 ft Max Head (Shut-off)\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003e1 1\/4 in NPT Discharge\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003eNEMA 3R Drive Enclosure\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003eDrinking Water ANSI\/NSF 61\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003e40-90 lb Weight\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background:#FFFFFF;border:1px solid #C7CBD1;border-top:3px solid #B3122A;padding:12px 16px 12px;margin:16px 0 4px;font-size:13.5px;line-height:1.55;color:#4A4A4F\"\u003e\n\u003cdiv style=\"font-family:Arial Black,Arial,sans-serif;font-size:11px;letter-spacing:1.2px;text-transform:uppercase;color:#B3122A;margin-bottom:8px\"\u003eWhat Ships and What It Needs to Run\u003c\/div\u003e\n\u003cp style=\"margin:0 0 6px\"\u003e\u003cstrong style=\"color:#B3122A\"\u003eIncluded:\u003c\/strong\u003e the pump end and Baker 4 in motor, assembled, with the AutoDRIVE constant pressure drive matched to the motor, and the pressure switch (APS models) or pressure transducer with 10 ft wire (APT models). The drive model for each build is in the Models table.\u003c\/p\u003e\n\u003cp style=\"margin:0 0 6px\"\u003e\u003cstrong style=\"color:#B3122A\"\u003ePower:\u003c\/strong\u003e 230V single-phase supply from a circuit breaker for every build; the three-phase builds take single-phase power and the drive makes three-phase for the motor. Breaker sizes are under Before You Buy.\u003c\/p\u003e\n\u003cp style=\"margin:0\"\u003e\u003cstrong style=\"color:#B3122A\"\u003eSized at install:\u003c\/strong\u003e drop cable, splice kit and the pressure relief valve shown in the manufacturer’s installation diagram.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eOverview\u003c\/div\u003e\n\u003cdiv class=\"gs-lead\"\u003e\n\u003cp\u003eThe AutoPAC is Baker’s constant pressure well package: a 24000 Series 4 in submersible pump, a Baker motor of the same horsepower, and the AutoDRIVE variable frequency drive. The drive holds a set pressure by changing the pump speed, which allows a smaller pressure tank and a quick, simple installation; setup takes 5 steps or less on the drive’s backlit display.\u003c\/p\u003e\n\u003cp\u003eThis listing is the \u003cstrong\u003eK - 10 GPM\u003c\/strong\u003e class: 1\/2 to 5 HP, with pressure switch and transducer control. The AutoDRIVE is American made and housed in a NEMA 3R steel enclosure rated for outdoor use.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background:#E1E3E6;border-left:3px solid #B8BDC4;padding:8px 14px;font-size:11.5px;color:#4A4A4F;margin-top:14px;line-height:1.5\"\u003eGenuine A.Y. McDonald equipment, factory-new in original packaging — sold and supported by Watermain Supply, an independent industrial supplier. Watermain Supply is an Authorized Stocking A.Y. McDonald and Baker Water Systems Distributor.\u003c\/div\u003e\n\u003cdiv style=\"background:#fff;border-left:5px solid #B3122A;padding:15px 18px;margin-top:12px\"\u003e\n\u003cdiv style=\"font-family:Arial Black,Arial,sans-serif;font-size:15px;color:#B3122A;text-transform:uppercase;letter-spacing:1px;margin-bottom:6px\"\u003eA.Y. McDonald Warranty\u003c\/div\u003e\n\u003cp style=\"margin:0;font-size:13.5px;color:#4A4A4F;line-height:1.55\"\u003ePump and motor: covered for \u003cstrong\u003e5 years from the date of manufacture in potable water applications\u003c\/strong\u003e, and 3 years from the date of manufacture in other applications, under A.Y. McDonald’s published terms for Baker submersible motors and assembled submersible pumps. The AutoDRIVE and pressure control fall under A.Y. McDonald’s standard limited warranty: 2 years from the date of manufacture or 1 year from installation, whichever comes first.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eRoom to Grow\u003c\/div\u003e\n\u003cdiv class=\"gs-lead\"\u003e\n\u003cp\u003eOne pump and one drive per well. Need more head later? Step up in horsepower within the K - 10 GPM class; the drive model changes with the motor (see the Models table). Need more flow? Move to a higher flow class of the AutoPAC 24000 Series; every class uses the same 1 1\/4 in NPT discharge.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eModels \u0026amp; Ratings (60 Hz)\u003c\/div\u003e\n\u003cdiv class=\"gs-lead\"\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003cth\u003ePart No.\u003c\/th\u003e\n\u003cth\u003eHP\u003c\/th\u003e\n\u003cth\u003eMotor\u003c\/th\u003e\n\u003cth\u003eControl\u003c\/th\u003e\n\u003cth\u003eAutoDRIVE\u003c\/th\u003e\n\u003cth\u003eHead at 10 GPM\u003c\/th\u003e\n\u003cth\u003eShut-off Head\u003c\/th\u003e\n\u003cth\u003eWeight\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e24050K2-APS\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6630-703\u003c\/td\u003e\n\u003ctd\u003e1\/2\u003c\/td\u003e\n\u003ctd\u003e230V 1Ph 2-Wire\u003c\/td\u003e\n\u003ctd\u003ePressure Switch\u003c\/td\u003e\n\u003ctd\u003eSD1-2HP2PS\u003c\/td\u003e\n\u003ctd\u003e160 ft\u003c\/td\u003e\n\u003ctd\u003e220 ft\u003c\/td\u003e\n\u003ctd\u003e42 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e24050K2-APT\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6630-698\u003c\/td\u003e\n\u003ctd\u003e1\/2\u003c\/td\u003e\n\u003ctd\u003e230V 1Ph 2-Wire\u003c\/td\u003e\n\u003ctd\u003eTransducer\u003c\/td\u003e\n\u003ctd\u003eSD1-2HP2\u003c\/td\u003e\n\u003ctd\u003e160 ft\u003c\/td\u003e\n\u003ctd\u003e220 ft\u003c\/td\u003e\n\u003ctd\u003e42 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e24050K3-APS\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6630-747\u003c\/td\u003e\n\u003ctd\u003e1\/2\u003c\/td\u003e\n\u003ctd\u003e230V 1Ph 3-Wire\u003c\/td\u003e\n\u003ctd\u003ePressure Switch\u003c\/td\u003e\n\u003ctd\u003eSD1-2HP2PS\u003c\/td\u003e\n\u003ctd\u003e160 ft\u003c\/td\u003e\n\u003ctd\u003e220 ft\u003c\/td\u003e\n\u003ctd\u003e40 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e24050K3-APT\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6630-742\u003c\/td\u003e\n\u003ctd\u003e1\/2\u003c\/td\u003e\n\u003ctd\u003e230V 1Ph 3-Wire\u003c\/td\u003e\n\u003ctd\u003eTransducer\u003c\/td\u003e\n\u003ctd\u003eSD1-2HP2\u003c\/td\u003e\n\u003ctd\u003e160 ft\u003c\/td\u003e\n\u003ctd\u003e220 ft\u003c\/td\u003e\n\u003ctd\u003e40 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e24075K2-APS\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6630-713\u003c\/td\u003e\n\u003ctd\u003e3\/4\u003c\/td\u003e\n\u003ctd\u003e230V 1Ph 2-Wire\u003c\/td\u003e\n\u003ctd\u003ePressure Switch\u003c\/td\u003e\n\u003ctd\u003eSD1-2HP2PS\u003c\/td\u003e\n\u003ctd\u003e234 ft\u003c\/td\u003e\n\u003ctd\u003e316 ft\u003c\/td\u003e\n\u003ctd\u003e45 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e24075K2-APT\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6630-708\u003c\/td\u003e\n\u003ctd\u003e3\/4\u003c\/td\u003e\n\u003ctd\u003e230V 1Ph 2-Wire\u003c\/td\u003e\n\u003ctd\u003eTransducer\u003c\/td\u003e\n\u003ctd\u003eSD1-2HP2\u003c\/td\u003e\n\u003ctd\u003e234 ft\u003c\/td\u003e\n\u003ctd\u003e316 ft\u003c\/td\u003e\n\u003ctd\u003e45 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e24075K3-APS\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6630-757\u003c\/td\u003e\n\u003ctd\u003e3\/4\u003c\/td\u003e\n\u003ctd\u003e230V 1Ph 3-Wire\u003c\/td\u003e\n\u003ctd\u003ePressure Switch\u003c\/td\u003e\n\u003ctd\u003eSD1-2HP2PS\u003c\/td\u003e\n\u003ctd\u003e234 ft\u003c\/td\u003e\n\u003ctd\u003e316 ft\u003c\/td\u003e\n\u003ctd\u003e42 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e24075K3-APT\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6630-752\u003c\/td\u003e\n\u003ctd\u003e3\/4\u003c\/td\u003e\n\u003ctd\u003e230V 1Ph 3-Wire\u003c\/td\u003e\n\u003ctd\u003eTransducer\u003c\/td\u003e\n\u003ctd\u003eSD1-2HP2\u003c\/td\u003e\n\u003ctd\u003e234 ft\u003c\/td\u003e\n\u003ctd\u003e316 ft\u003c\/td\u003e\n\u003ctd\u003e42 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e24100K2-APS\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6630-724\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003ctd\u003e230V 1Ph 2-Wire\u003c\/td\u003e\n\u003ctd\u003ePressure Switch\u003c\/td\u003e\n\u003ctd\u003eSD1-2HP2PS\u003c\/td\u003e\n\u003ctd\u003e272 ft\u003c\/td\u003e\n\u003ctd\u003e379 ft\u003c\/td\u003e\n\u003ctd\u003e50 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e24100K2-APT\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6630-718\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003ctd\u003e230V 1Ph 2-Wire\u003c\/td\u003e\n\u003ctd\u003eTransducer\u003c\/td\u003e\n\u003ctd\u003eSD1-2HP2\u003c\/td\u003e\n\u003ctd\u003e272 ft\u003c\/td\u003e\n\u003ctd\u003e379 ft\u003c\/td\u003e\n\u003ctd\u003e50 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e24100K3-APS\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6630-768\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003ctd\u003e230V 1Ph 3-Wire\u003c\/td\u003e\n\u003ctd\u003ePressure Switch\u003c\/td\u003e\n\u003ctd\u003eSD1-2HP2PS\u003c\/td\u003e\n\u003ctd\u003e272 ft\u003c\/td\u003e\n\u003ctd\u003e379 ft\u003c\/td\u003e\n\u003ctd\u003e49 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e24100K3-APT\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6630-762\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003ctd\u003e230V 1Ph 3-Wire\u003c\/td\u003e\n\u003ctd\u003eTransducer\u003c\/td\u003e\n\u003ctd\u003eSD1-2HP2\u003c\/td\u003e\n\u003ctd\u003e272 ft\u003c\/td\u003e\n\u003ctd\u003e379 ft\u003c\/td\u003e\n\u003ctd\u003e49 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e24150K2-APS\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6630-736\u003c\/td\u003e\n\u003ctd\u003e1 1\/2\u003c\/td\u003e\n\u003ctd\u003e230V 1Ph 2-Wire\u003c\/td\u003e\n\u003ctd\u003ePressure Switch\u003c\/td\u003e\n\u003ctd\u003eSD1-2HP2PS\u003c\/td\u003e\n\u003ctd\u003e399 ft\u003c\/td\u003e\n\u003ctd\u003e543 ft\u003c\/td\u003e\n\u003ctd\u003e57 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e24150K2-APT\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6630-730\u003c\/td\u003e\n\u003ctd\u003e1 1\/2\u003c\/td\u003e\n\u003ctd\u003e230V 1Ph 2-Wire\u003c\/td\u003e\n\u003ctd\u003eTransducer\u003c\/td\u003e\n\u003ctd\u003eSD1-2HP2\u003c\/td\u003e\n\u003ctd\u003e399 ft\u003c\/td\u003e\n\u003ctd\u003e543 ft\u003c\/td\u003e\n\u003ctd\u003e57 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e24150K3-APS\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6630-780\u003c\/td\u003e\n\u003ctd\u003e1 1\/2\u003c\/td\u003e\n\u003ctd\u003e230V 1Ph 3-Wire\u003c\/td\u003e\n\u003ctd\u003ePressure Switch\u003c\/td\u003e\n\u003ctd\u003eSD1-2HP2PS\u003c\/td\u003e\n\u003ctd\u003e399 ft\u003c\/td\u003e\n\u003ctd\u003e543 ft\u003c\/td\u003e\n\u003ctd\u003e56 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e24150K3-APT\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6630-774\u003c\/td\u003e\n\u003ctd\u003e1 1\/2\u003c\/td\u003e\n\u003ctd\u003e230V 1Ph 3-Wire\u003c\/td\u003e\n\u003ctd\u003eTransducer\u003c\/td\u003e\n\u003ctd\u003eSD1-2HP2\u003c\/td\u003e\n\u003ctd\u003e399 ft\u003c\/td\u003e\n\u003ctd\u003e543 ft\u003c\/td\u003e\n\u003ctd\u003e56 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e24150K3Z-APT\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6630-857\u003c\/td\u003e\n\u003ctd\u003e1 1\/2\u003c\/td\u003e\n\u003ctd\u003e230V 3Ph\u003c\/td\u003e\n\u003ctd\u003eTransducer\u003c\/td\u003e\n\u003ctd\u003eSD3-2HP2\u003c\/td\u003e\n\u003ctd\u003e399 ft\u003c\/td\u003e\n\u003ctd\u003e543 ft\u003c\/td\u003e\n\u003ctd\u003e49 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e24200K3-APS\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6630-790\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e230V 1Ph 3-Wire\u003c\/td\u003e\n\u003ctd\u003ePressure Switch\u003c\/td\u003e\n\u003ctd\u003eSD1-2HP2PS\u003c\/td\u003e\n\u003ctd\u003e470 ft\u003c\/td\u003e\n\u003ctd\u003e639 ft\u003c\/td\u003e\n\u003ctd\u003e57 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e24200K3-APT\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6630-785\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e230V 1Ph 3-Wire\u003c\/td\u003e\n\u003ctd\u003eTransducer\u003c\/td\u003e\n\u003ctd\u003eSD1-2HP2\u003c\/td\u003e\n\u003ctd\u003e470 ft\u003c\/td\u003e\n\u003ctd\u003e639 ft\u003c\/td\u003e\n\u003ctd\u003e57 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e24200K3Z-APT\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6630-795\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e230V 3Ph\u003c\/td\u003e\n\u003ctd\u003eTransducer\u003c\/td\u003e\n\u003ctd\u003eSD3-2HP2\u003c\/td\u003e\n\u003ctd\u003e470 ft\u003c\/td\u003e\n\u003ctd\u003e639 ft\u003c\/td\u003e\n\u003ctd\u003e55 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e24300K3Z-APT\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6630-799\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003ctd\u003e230V 3Ph\u003c\/td\u003e\n\u003ctd\u003eTransducer\u003c\/td\u003e\n\u003ctd\u003eSD3-3HP2\u003c\/td\u003e\n\u003ctd\u003e639 ft\u003c\/td\u003e\n\u003ctd\u003e862 ft\u003c\/td\u003e\n\u003ctd\u003e69 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e24500K3Z-APT\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6630-803\u003c\/td\u003e\n\u003ctd\u003e5\u003c\/td\u003e\n\u003ctd\u003e230V 3Ph\u003c\/td\u003e\n\u003ctd\u003eTransducer\u003c\/td\u003e\n\u003ctd\u003eSD3-5HP2\u003c\/td\u003e\n\u003ctd\u003e994 ft\u003c\/td\u003e\n\u003ctd\u003e1340 ft\u003c\/td\u003e\n\u003ctd\u003e90 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"font-size:12.5px;color:#9B9EA3;margin-top:8px;line-height:1.55\"\u003eHead at 10 GPM is read from the published AutoPAC curve (Pumps by Baker catalog (Sept 2025, rev 3\/26), p. 150), digitized and rounded down. Shut-off head as printed. Drive per the compatibility table on p. 141 (1 1\/2 HP three-phase builds use the SD3-2HP2). Sources: Pumps by Baker catalog (Sept 2025, rev 3\/26), pp. 141-143 and 150; Baker Pumps and Accessories price list, effective 7\/1\/2026.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eShared Specifications\u003c\/div\u003e\n\u003cdiv class=\"gs-lead\"\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eIncluded\u003c\/td\u003e\n\u003ctd\u003ePump end, Baker 4 in motor, AutoDRIVE drive, and pressure switch or transducer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDischarge\u003c\/td\u003e\n\u003ctd\u003e1 1\/4 in NPT (female)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCheck valve\u003c\/td\u003e\n\u003ctd\u003eBuilt in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply\u003c\/td\u003e\n\u003ctd\u003e230V single-phase, 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor\u003c\/td\u003e\n\u003ctd\u003eBaker 4 in submersible motor, matched to the pump end horsepower\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePump diameter\u003c\/td\u003e\n\u003ctd\u003e3 3\/4 in with cable guard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrive enclosure\u003c\/td\u003e\n\u003ctd\u003eNEMA Type 3R steel, 12.25 x 9.25 x 4.68 in, 13 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrive operating temperature\u003c\/td\u003e\n\u003ctd\u003e-4 to 122°F; SD3-5HP2 rated to 104°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrive efficiency\u003c\/td\u003e\n\u003ctd\u003e95%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertification (pump)\u003c\/td\u003e\n\u003ctd\u003eDrinking Water ANSI\/NSF 61\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApp connection\u003c\/td\u003e\n\u003ctd\u003eNone; set up on the drive display\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"font-size:12.5px;color:#9B9EA3;margin-top:8px;line-height:1.55\"\u003eSource: Pumps by Baker catalog (Sept 2025, rev 3\/26), pp. 131-133 and 141-143.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003ePerformance — Will It Do What You Need?\u003c\/div\u003e\n\u003cdiv class=\"gs-lead\"\u003e\n\u003cp\u003e\u003cstrong\u003eTotal head\u003c\/strong\u003e is everything the pump lifts against: the vertical lift from the pumping water level to the discharge, the pressure you set on the drive (2.31 ft for every PSI), and friction in the drop pipe. The drive slows the pump when demand falls, so the curve below is the most the pump delivers at full speed.\u003c\/p\u003e\n\u003cp style=\"margin-bottom:4px\"\u003e\u003cstrong\u003eTotal head in feet, by flow in GPM, at full speed\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eHP (stages)\u003c\/th\u003e\n\u003cth\u003e0\u003c\/th\u003e\n\u003cth\u003e2.5\u003c\/th\u003e\n\u003cth\u003e5\u003c\/th\u003e\n\u003cth\u003e7.5\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003e10\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e12.5\u003c\/th\u003e\n\u003cth\u003e15\u003c\/th\u003e\n\u003cth\u003e17.5\u003c\/th\u003e\n\u003cth\u003e20\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e1\/2 HP (7)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e219\u003c\/td\u003e\n\u003ctd\u003e214\u003c\/td\u003e\n\u003ctd\u003e202\u003c\/td\u003e\n\u003ctd\u003e184\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e160\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e131\u003c\/td\u003e\n\u003ctd\u003e96\u003c\/td\u003e\n\u003ctd\u003e56\u003c\/td\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e3\/4 HP (10)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e317\u003c\/td\u003e\n\u003ctd\u003e309\u003c\/td\u003e\n\u003ctd\u003e293\u003c\/td\u003e\n\u003ctd\u003e267\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e234\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e191\u003c\/td\u003e\n\u003ctd\u003e140\u003c\/td\u003e\n\u003ctd\u003e80\u003c\/td\u003e\n\u003ctd\u003e11\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e1 HP (12)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e380\u003c\/td\u003e\n\u003ctd\u003e367\u003c\/td\u003e\n\u003ctd\u003e345\u003c\/td\u003e\n\u003ctd\u003e314\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e272\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e220\u003c\/td\u003e\n\u003ctd\u003e158\u003c\/td\u003e\n\u003ctd\u003e87\u003c\/td\u003e\n\u003ctd\u003e5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e1 1\/2 HP (17)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e545\u003c\/td\u003e\n\u003ctd\u003e531\u003c\/td\u003e\n\u003ctd\u003e503\u003c\/td\u003e\n\u003ctd\u003e459\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e399\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e325\u003c\/td\u003e\n\u003ctd\u003e234\u003c\/td\u003e\n\u003ctd\u003e129\u003c\/td\u003e\n\u003ctd\u003e7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e2 HP (20)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e638\u003c\/td\u003e\n\u003ctd\u003e624\u003c\/td\u003e\n\u003ctd\u003e591\u003c\/td\u003e\n\u003ctd\u003e539\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e470\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e382\u003c\/td\u003e\n\u003ctd\u003e275\u003c\/td\u003e\n\u003ctd\u003e151\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e3 HP (27)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e862\u003c\/td\u003e\n\u003ctd\u003e837\u003c\/td\u003e\n\u003ctd\u003e798\u003c\/td\u003e\n\u003ctd\u003e733\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e639\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e515\u003c\/td\u003e\n\u003ctd\u003e365\u003c\/td\u003e\n\u003ctd\u003e197\u003c\/td\u003e\n\u003ctd\u003e23\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e5 HP (42)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1341\u003c\/td\u003e\n\u003ctd\u003e1302\u003c\/td\u003e\n\u003ctd\u003e1240\u003c\/td\u003e\n\u003ctd\u003e1140\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e994\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e801\u003c\/td\u003e\n\u003ctd\u003e567\u003c\/td\u003e\n\u003ctd\u003e306\u003c\/td\u003e\n\u003ctd\u003e35\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"font-size:12.5px;color:#9B9EA3;margin-top:6px;line-height:1.55\"\u003eDigitized from the published AutoPAC curve in the Pumps by Baker catalog (Sept 2025, rev 3\/26), p. 150, and rounded down. Rated flow (10 GPM) in bold. Zero flow is the shut-off point, a ceiling rather than a working point; — marks flows past the end of that curve.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBest operating range:\u003c\/strong\u003e the published curve shades the most efficient operating range; the catalog prints no figures for it. The curve is in the image gallery.\u003c\/p\u003e\n\u003cdiv style=\"display:flex;flex-wrap:wrap;gap:10px;margin:22px 0 4px\"\u003e\n\u003ca href=\"\/pages\/submersible-well-pump-sizing-calculator\" style=\"flex:1 1 200px;text-align:center;display:block;background:#B3122A;color:#ffffff;font-family:Arial Black,Arial,sans-serif;font-size:12px;text-transform:uppercase;letter-spacing:1.2px;padding:11px 18px;text-decoration:none\"\u003eSubmersible Calculator\u003c\/a\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eBefore You Buy — The Limits That Decide the Fit\u003c\/div\u003e\n\u003cdiv class=\"gs-lead\"\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply\u003c\/td\u003e\n\u003ctd\u003e230V single-phase for every build, from a circuit breaker sized per the table below\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure transducer\u003c\/td\u003e\n\u003ctd\u003eMust be installed upright and vertical (manufacturer note)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrive location\u003c\/td\u003e\n\u003ctd\u003eNEMA 3R enclosure, outdoors or indoors; rated to 122°F (104°F for SD3-5HP2); derate above 5500 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor cooling\u003c\/td\u003e\n\u003ctd\u003e1.0 ft\/sec of water flow past the motor at 95°F; motor rated to 95°F water\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWell size\u003c\/td\u003e\n\u003ctd\u003e4 in casing and larger\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePairing\u003c\/td\u003e\n\u003ctd\u003eOne pump and one drive per well\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"margin:14px 0 4px\"\u003e\u003cstrong\u003eBreaker sizing by motor HP (manufacturer recommendation)\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSupply\u003c\/th\u003e\n\u003cth\u003eMotor HP\u003c\/th\u003e\n\u003cth\u003eInput Current\u003c\/th\u003e\n\u003cth\u003eFuse \/ Breaker\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e230V\u003c\/td\u003e\n\u003ctd\u003e1\/2\u003c\/td\u003e\n\u003ctd\u003e6 A\u003c\/td\u003e\n\u003ctd\u003e10 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e230V\u003c\/td\u003e\n\u003ctd\u003e3\/4\u003c\/td\u003e\n\u003ctd\u003e9 A\u003c\/td\u003e\n\u003ctd\u003e15 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e230V\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003ctd\u003e14 A\u003c\/td\u003e\n\u003ctd\u003e20 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e230V\u003c\/td\u003e\n\u003ctd\u003e1 1\/2\u003c\/td\u003e\n\u003ctd\u003e18 A\u003c\/td\u003e\n\u003ctd\u003e25 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e230V\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e28 A\u003c\/td\u003e\n\u003ctd\u003e35 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e230V\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e20 A\u003c\/td\u003e\n\u003ctd\u003e25 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e230V\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003ctd\u003e30 A\u003c\/td\u003e\n\u003ctd\u003e40 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e230V\u003c\/td\u003e\n\u003ctd\u003e5\u003c\/td\u003e\n\u003ctd\u003e42 A\u003c\/td\u003e\n\u003ctd\u003e55 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"font-size:12.5px;color:#9B9EA3;margin-top:8px;line-height:1.55\"\u003eSource: Pumps by Baker catalog (Sept 2025, rev 3\/26), p. 131.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eMaterials of Construction (Pump)\u003c\/div\u003e\n\u003cdiv class=\"gs-lead\"\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eDischarge head\u003c\/td\u003e\n\u003ctd\u003eStainless steel 304, 1 1\/4 in NPT discharge\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor adapter\u003c\/td\u003e\n\u003ctd\u003eStainless steel 304, NEMA standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCheck valve\u003c\/td\u003e\n\u003ctd\u003eStainless steel 304\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExternal shell\u003c\/td\u003e\n\u003ctd\u003eStainless steel 304, polished\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eImpellers\u003c\/td\u003e\n\u003ctd\u003eNoryl\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiffusers\u003c\/td\u003e\n\u003ctd\u003ePolycarbonate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBearing\u003c\/td\u003e\n\u003ctd\u003ePolyacetal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShaft coupling\u003c\/td\u003e\n\u003ctd\u003eStainless steel 304, NEMA standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStrainer\u003c\/td\u003e\n\u003ctd\u003eThermoplastic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShaft\u003c\/td\u003e\n\u003ctd\u003eStainless steel 304\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable guard\u003c\/td\u003e\n\u003ctd\u003eStainless steel 304\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"font-size:12.5px;color:#9B9EA3;margin-top:8px;line-height:1.55\"\u003eSource: Pumps by Baker catalog (Sept 2025, rev 3\/26), pp. 65-66.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eService Parts\u003c\/div\u003e\n\u003cdiv class=\"gs-lead\"\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003ePart\u003c\/th\u003e\n\u003cth\u003ePart No.\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutoDRIVE pressure transducer with 10 ft wire\u003c\/td\u003e\n\u003ctd\u003e6619-028\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutoDRIVE pressure switch with wire\u003c\/td\u003e\n\u003ctd\u003e6619-029\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutoDRIVE keypad\u003c\/td\u003e\n\u003ctd\u003e6619-030\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"font-size:12.5px;color:#9B9EA3;margin-top:8px;line-height:1.55\"\u003eSource: Pumps by Baker catalog (Sept 2025, rev 3\/26), pp. 142-143.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"gs-contact\"\u003eFor engineering-led sizing and selection support or a factory submittal, email \u003ca href=\"mailto:sales@watermainsupply.com\"\u003esales@watermainsupply.com\u003c\/a\u003e or call \u003ca href=\"tel:18885104036\"\u003e1-888.510.4036\u003c\/a\u003e.\u003cbr\u003e© Watermain Supply — A division of E4 Industrial LLC\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch5\u003eData Sheet\u003c\/h5\u003e\n\u003cdiv class=\"gs\"\u003e\n\u003cdiv class=\"gs-dl\"\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0264\/1913\/4527\/files\/AutoPac_Guide.pdf?v=1772502299\" target=\"_blank\" rel=\"noopener\"\u003ePumps by Baker AutoPac Guide\u003c\/a\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch5\u003eVideos\u003c\/h5\u003e\n\u003cdiv class=\"gs\"\u003e\u003cdiv class=\"gs-sec\" style=\"margin-top:6px\"\u003e\n\u003cp style=\"font-size:13px;color:#9B9EA3\"\u003eProduct videos are being added to this listing. For a walkthrough in the meantime, email sales@watermainsupply.com.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003c!-- \/TABS --\u003e","brand":"A.Y. McDonald","offers":[{"title":"1\/2 HP - 4 in Motor \/ 230V 1Ph 2-Wire \/ Switch - 24050K2-APS - 160 ft at 10 GPM","offer_id":46602931732655,"sku":"6630-703","price":1816.59,"currency_code":"USD","in_stock":true},{"title":"1\/2 HP - 4 in Motor \/ 230V 1Ph 2-Wire \/ Transducer - 24050K2-APT - 160 ft at 10 GPM","offer_id":46602931863727,"sku":"6630-698","price":1995.49,"currency_code":"USD","in_stock":true},{"title":"1\/2 HP - 4 in Motor \/ 230V 1Ph 3-Wire \/ Switch - 24050K3-APS - 160 ft at 10 GPM","offer_id":46602931994799,"sku":"6630-747","price":1730.72,"currency_code":"USD","in_stock":true},{"title":"1\/2 HP - 4 in Motor \/ 230V 1Ph 3-Wire \/ Transducer - 24050K3-APT - 160 ft at 10 GPM","offer_id":46602932158639,"sku":"6630-742","price":1909.61,"currency_code":"USD","in_stock":true},{"title":"3\/4 HP - 4 in Motor \/ 230V 1Ph 2-Wire \/ Switch - 24075K2-APS - 234 ft at 10 GPM","offer_id":46602931765423,"sku":"6630-713","price":2022.57,"currency_code":"USD","in_stock":true},{"title":"3\/4 HP - 4 in Motor \/ 230V 1Ph 2-Wire \/ Transducer - 24075K2-APT - 234 ft at 10 GPM","offer_id":46602931896495,"sku":"6630-708","price":2200.96,"currency_code":"USD","in_stock":true},{"title":"3\/4 HP - 4 in Motor \/ 230V 1Ph 3-Wire \/ Switch - 24075K3-APS - 234 ft at 10 GPM","offer_id":46602932027567,"sku":"6630-757","price":1907.56,"currency_code":"USD","in_stock":true},{"title":"3\/4 HP - 4 in Motor \/ 230V 1Ph 3-Wire \/ Transducer - 24075K3-APT - 234 ft at 10 GPM","offer_id":46602932191407,"sku":"6630-752","price":2085.44,"currency_code":"USD","in_stock":true},{"title":"1 HP - 4 in Motor \/ 230V 1Ph 2-Wire \/ Switch - 24100K2-APS - 272 ft at 10 GPM","offer_id":46602931798191,"sku":"6630-724","price":2107.41,"currency_code":"USD","in_stock":true},{"title":"1 HP - 4 in Motor \/ 230V 1Ph 2-Wire \/ Transducer - 24100K2-APT - 272 ft at 10 GPM","offer_id":46602931929263,"sku":"6630-718","price":2286.83,"currency_code":"USD","in_stock":true},{"title":"1 HP - 4 in Motor \/ 230V 1Ph 3-Wire \/ Switch - 24100K3-APS - 272 ft at 10 GPM","offer_id":46602932060335,"sku":"6630-768","price":1966.86,"currency_code":"USD","in_stock":true},{"title":"1 HP - 4 in Motor \/ 230V 1Ph 3-Wire \/ Transducer - 24100K3-APT - 272 ft at 10 GPM","offer_id":46602932224175,"sku":"6630-762","price":2145.25,"currency_code":"USD","in_stock":true},{"title":"1 1\/2 HP - 4 in Motor \/ 230V 1Ph 2-Wire \/ Switch - 24150K2-APS - 399 ft at 10 GPM","offer_id":46602931830959,"sku":"6630-736","price":2519.94,"currency_code":"USD","in_stock":true},{"title":"1 1\/2 HP - 4 in Motor \/ 230V 1Ph 2-Wire \/ Transducer - 24150K2-APT - 399 ft at 10 GPM","offer_id":46602931962031,"sku":"6630-730","price":2698.84,"currency_code":"USD","in_stock":true},{"title":"1 1\/2 HP - 4 in Motor \/ 230V 1Ph 3-Wire \/ Switch - 24150K3-APS - 399 ft at 10 GPM","offer_id":46602932093103,"sku":"6630-780","price":2336.45,"currency_code":"USD","in_stock":true},{"title":"1 1\/2 HP - 4 in Motor \/ 230V 1Ph 3-Wire \/ Transducer - 24150K3-APT - 399 ft at 10 GPM","offer_id":46602932256943,"sku":"6630-774","price":2514.83,"currency_code":"USD","in_stock":true},{"title":"1 1\/2 HP - 4 in Motor \/ 230V 3Ph \/ Transducer - 24150K3Z-APT - 399 ft at 10 GPM","offer_id":46602932322479,"sku":"6630-857","price":2737.13,"currency_code":"USD","in_stock":true},{"title":"2 HP - 4 in Motor \/ 230V 1Ph 3-Wire \/ Switch - 24200K3-APS - 470 ft at 10 GPM","offer_id":46602932125871,"sku":"6630-790","price":2632.9,"currency_code":"USD","in_stock":true},{"title":"2 HP - 4 in Motor \/ 230V 1Ph 3-Wire \/ Transducer - 24200K3-APT - 470 ft at 10 GPM","offer_id":46602932289711,"sku":"6630-785","price":2812.81,"currency_code":"USD","in_stock":true},{"title":"2 HP - 4 in Motor \/ 230V 3Ph \/ Transducer - 24200K3Z-APT - 470 ft at 10 GPM","offer_id":46602932355247,"sku":"6630-795","price":3030.05,"currency_code":"USD","in_stock":true},{"title":"3 HP - 4 in Motor \/ 230V 3Ph \/ Transducer - 24300K3Z-APT - 639 ft at 10 GPM","offer_id":46602932388015,"sku":"6630-799","price":3784.98,"currency_code":"USD","in_stock":true},{"title":"5 HP - 4 in Motor \/ 230V 3Ph \/ Transducer - 24500K3Z-APT - 994 ft at 10 GPM","offer_id":46602932420783,"sku":"6630-803","price":5311.31,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0264\/1913\/4527\/files\/AutoPac_666beb17-c7a0-4c4c-b608-a3f8948266d4.png?v=1772502610"},{"product_id":"baker-autopac-l-15-gpm-24000-series","title":"A.Y. McDonald AutoPAC L - 15 GPM 24000 Constant Pressure Pump","description":"\u003c!-- TABS --\u003e\n\u003ch5\u003eDescription\u003c\/h5\u003e\n\u003cdiv class=\"gs\"\u003e\n\u003cdiv class=\"gs-head\"\u003e\n\u003cdiv class=\"gs-eyebrow\"\u003eA.Y. McDonald · Constant Pressure Pump System\u003c\/div\u003e\n\u003cdiv class=\"gs-title\"\u003eAutoPAC L - 15 GPM, 24000 Series\u003c\/div\u003e\n\u003cdiv class=\"gs-sub\"\u003eBaker stainless steel 4 in submersible pump, motor and AutoDRIVE constant pressure drive, 1\/2 to 5 HP, 22 builds.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"gs-badges\"\u003e\n\u003cdiv class=\"gs-badge\" style=\"background:#B3122A;color:#FFFFFF;border-color:#B3122A\"\u003e93-700 ft at 15 GPM\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003e1\/2-5 HP\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003e230V Single-Phase Supply\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003eAutoDRIVE Constant Pressure VFD\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003ePressure Switch or Transducer Control\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003e1084 ft Max Head (Shut-off)\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003e1 1\/4 in NPT Discharge\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003eNEMA 3R Drive Enclosure\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003eDrinking Water ANSI\/NSF 61\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003e39-86 lb Weight\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background:#FFFFFF;border:1px solid #C7CBD1;border-top:3px solid #B3122A;padding:12px 16px 12px;margin:16px 0 4px;font-size:13.5px;line-height:1.55;color:#4A4A4F\"\u003e\n\u003cdiv style=\"font-family:Arial Black,Arial,sans-serif;font-size:11px;letter-spacing:1.2px;text-transform:uppercase;color:#B3122A;margin-bottom:8px\"\u003eWhat Ships and What It Needs to Run\u003c\/div\u003e\n\u003cp style=\"margin:0 0 6px\"\u003e\u003cstrong style=\"color:#B3122A\"\u003eIncluded:\u003c\/strong\u003e the pump end and Baker 4 in motor, assembled, with the AutoDRIVE constant pressure drive matched to the motor, and the pressure switch (APS models) or pressure transducer with 10 ft wire (APT models). The drive model for each build is in the Models table.\u003c\/p\u003e\n\u003cp style=\"margin:0 0 6px\"\u003e\u003cstrong style=\"color:#B3122A\"\u003ePower:\u003c\/strong\u003e 230V single-phase supply from a circuit breaker for every build; the three-phase builds take single-phase power and the drive makes three-phase for the motor. Breaker sizes are under Before You Buy.\u003c\/p\u003e\n\u003cp style=\"margin:0\"\u003e\u003cstrong style=\"color:#B3122A\"\u003eSized at install:\u003c\/strong\u003e drop cable, splice kit and the pressure relief valve shown in the manufacturer’s installation diagram.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eOverview\u003c\/div\u003e\n\u003cdiv class=\"gs-lead\"\u003e\n\u003cp\u003eThe AutoPAC is Baker’s constant pressure well package: a 24000 Series 4 in submersible pump, a Baker motor of the same horsepower, and the AutoDRIVE variable frequency drive. The drive holds a set pressure by changing the pump speed, which allows a smaller pressure tank and a quick, simple installation; setup takes 5 steps or less on the drive’s backlit display.\u003c\/p\u003e\n\u003cp\u003eThis listing is the \u003cstrong\u003eL - 15 GPM\u003c\/strong\u003e class: 1\/2 to 5 HP, with pressure switch and transducer control. The AutoDRIVE is American made and housed in a NEMA 3R steel enclosure rated for outdoor use.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background:#E1E3E6;border-left:3px solid #B8BDC4;padding:8px 14px;font-size:11.5px;color:#4A4A4F;margin-top:14px;line-height:1.5\"\u003eGenuine A.Y. McDonald equipment, factory-new in original packaging — sold and supported by Watermain Supply, an independent industrial supplier. Watermain Supply is an Authorized Stocking A.Y. McDonald and Baker Water Systems Distributor.\u003c\/div\u003e\n\u003cdiv style=\"background:#fff;border-left:5px solid #B3122A;padding:15px 18px;margin-top:12px\"\u003e\n\u003cdiv style=\"font-family:Arial Black,Arial,sans-serif;font-size:15px;color:#B3122A;text-transform:uppercase;letter-spacing:1px;margin-bottom:6px\"\u003eA.Y. McDonald Warranty\u003c\/div\u003e\n\u003cp style=\"margin:0;font-size:13.5px;color:#4A4A4F;line-height:1.55\"\u003ePump and motor: covered for \u003cstrong\u003e5 years from the date of manufacture in potable water applications\u003c\/strong\u003e, and 3 years from the date of manufacture in other applications, under A.Y. McDonald’s published terms for Baker submersible motors and assembled submersible pumps. The AutoDRIVE and pressure control fall under A.Y. McDonald’s standard limited warranty: 2 years from the date of manufacture or 1 year from installation, whichever comes first.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eRoom to Grow\u003c\/div\u003e\n\u003cdiv class=\"gs-lead\"\u003e\n\u003cp\u003eOne pump and one drive per well. Need more head later? Step up in horsepower within the L - 15 GPM class; the drive model changes with the motor (see the Models table). Need more flow? Move to a higher flow class of the AutoPAC 24000 Series; every class uses the same 1 1\/4 in NPT discharge.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eModels \u0026amp; Ratings (60 Hz)\u003c\/div\u003e\n\u003cdiv class=\"gs-lead\"\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003cth\u003ePart No.\u003c\/th\u003e\n\u003cth\u003eHP\u003c\/th\u003e\n\u003cth\u003eMotor\u003c\/th\u003e\n\u003cth\u003eControl\u003c\/th\u003e\n\u003cth\u003eAutoDRIVE\u003c\/th\u003e\n\u003cth\u003eHead at 15 GPM\u003c\/th\u003e\n\u003cth\u003eShut-off Head\u003c\/th\u003e\n\u003cth\u003eWeight\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e24050L2-APS\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6630-704\u003c\/td\u003e\n\u003ctd\u003e1\/2\u003c\/td\u003e\n\u003ctd\u003e230V 1Ph 2-Wire\u003c\/td\u003e\n\u003ctd\u003ePressure Switch\u003c\/td\u003e\n\u003ctd\u003eSD1-2HP2PS\u003c\/td\u003e\n\u003ctd\u003e93 ft\u003c\/td\u003e\n\u003ctd\u003e152 ft\u003c\/td\u003e\n\u003ctd\u003e41 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e24050L2-APT\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6630-699\u003c\/td\u003e\n\u003ctd\u003e1\/2\u003c\/td\u003e\n\u003ctd\u003e230V 1Ph 2-Wire\u003c\/td\u003e\n\u003ctd\u003eTransducer\u003c\/td\u003e\n\u003ctd\u003eSD1-2HP2\u003c\/td\u003e\n\u003ctd\u003e93 ft\u003c\/td\u003e\n\u003ctd\u003e152 ft\u003c\/td\u003e\n\u003ctd\u003e41 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e24050L3-APS\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6630-748\u003c\/td\u003e\n\u003ctd\u003e1\/2\u003c\/td\u003e\n\u003ctd\u003e230V 1Ph 3-Wire\u003c\/td\u003e\n\u003ctd\u003ePressure Switch\u003c\/td\u003e\n\u003ctd\u003eSD1-2HP2PS\u003c\/td\u003e\n\u003ctd\u003e93 ft\u003c\/td\u003e\n\u003ctd\u003e152 ft\u003c\/td\u003e\n\u003ctd\u003e39 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e24050L3-APT\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6630-743\u003c\/td\u003e\n\u003ctd\u003e1\/2\u003c\/td\u003e\n\u003ctd\u003e230V 1Ph 3-Wire\u003c\/td\u003e\n\u003ctd\u003eTransducer\u003c\/td\u003e\n\u003ctd\u003eSD1-2HP2\u003c\/td\u003e\n\u003ctd\u003e93 ft\u003c\/td\u003e\n\u003ctd\u003e152 ft\u003c\/td\u003e\n\u003ctd\u003e39 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e24075L2-APS\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6630-714\u003c\/td\u003e\n\u003ctd\u003e3\/4\u003c\/td\u003e\n\u003ctd\u003e230V 1Ph 2-Wire\u003c\/td\u003e\n\u003ctd\u003ePressure Switch\u003c\/td\u003e\n\u003ctd\u003eSD1-2HP2PS\u003c\/td\u003e\n\u003ctd\u003e132 ft\u003c\/td\u003e\n\u003ctd\u003e211 ft\u003c\/td\u003e\n\u003ctd\u003e44 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e24075L2-APT\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6630-709\u003c\/td\u003e\n\u003ctd\u003e3\/4\u003c\/td\u003e\n\u003ctd\u003e230V 1Ph 2-Wire\u003c\/td\u003e\n\u003ctd\u003eTransducer\u003c\/td\u003e\n\u003ctd\u003eSD1-2HP2\u003c\/td\u003e\n\u003ctd\u003e132 ft\u003c\/td\u003e\n\u003ctd\u003e211 ft\u003c\/td\u003e\n\u003ctd\u003e44 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e24075L3-APS\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6630-758\u003c\/td\u003e\n\u003ctd\u003e3\/4\u003c\/td\u003e\n\u003ctd\u003e230V 1Ph 3-Wire\u003c\/td\u003e\n\u003ctd\u003ePressure Switch\u003c\/td\u003e\n\u003ctd\u003eSD1-2HP2PS\u003c\/td\u003e\n\u003ctd\u003e132 ft\u003c\/td\u003e\n\u003ctd\u003e211 ft\u003c\/td\u003e\n\u003ctd\u003e41 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e24075L3-APT\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6630-753\u003c\/td\u003e\n\u003ctd\u003e3\/4\u003c\/td\u003e\n\u003ctd\u003e230V 1Ph 3-Wire\u003c\/td\u003e\n\u003ctd\u003eTransducer\u003c\/td\u003e\n\u003ctd\u003eSD1-2HP2\u003c\/td\u003e\n\u003ctd\u003e132 ft\u003c\/td\u003e\n\u003ctd\u003e211 ft\u003c\/td\u003e\n\u003ctd\u003e41 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e24100L2-APS\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6630-725\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003ctd\u003e230V 1Ph 2-Wire\u003c\/td\u003e\n\u003ctd\u003ePressure Switch\u003c\/td\u003e\n\u003ctd\u003eSD1-2HP2PS\u003c\/td\u003e\n\u003ctd\u003e190 ft\u003c\/td\u003e\n\u003ctd\u003e299 ft\u003c\/td\u003e\n\u003ctd\u003e50 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e24100L2-APT\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6630-719\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003ctd\u003e230V 1Ph 2-Wire\u003c\/td\u003e\n\u003ctd\u003eTransducer\u003c\/td\u003e\n\u003ctd\u003eSD1-2HP2\u003c\/td\u003e\n\u003ctd\u003e190 ft\u003c\/td\u003e\n\u003ctd\u003e299 ft\u003c\/td\u003e\n\u003ctd\u003e50 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e24100L3-APS\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6630-769\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003ctd\u003e230V 1Ph 3-Wire\u003c\/td\u003e\n\u003ctd\u003ePressure Switch\u003c\/td\u003e\n\u003ctd\u003eSD1-2HP2PS\u003c\/td\u003e\n\u003ctd\u003e190 ft\u003c\/td\u003e\n\u003ctd\u003e299 ft\u003c\/td\u003e\n\u003ctd\u003e49 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e24100L3-APT\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6630-763\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003ctd\u003e230V 1Ph 3-Wire\u003c\/td\u003e\n\u003ctd\u003eTransducer\u003c\/td\u003e\n\u003ctd\u003eSD1-2HP2\u003c\/td\u003e\n\u003ctd\u003e190 ft\u003c\/td\u003e\n\u003ctd\u003e299 ft\u003c\/td\u003e\n\u003ctd\u003e49 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e24150L2-APS\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6630-737\u003c\/td\u003e\n\u003ctd\u003e1 1\/2\u003c\/td\u003e\n\u003ctd\u003e230V 1Ph 2-Wire\u003c\/td\u003e\n\u003ctd\u003ePressure Switch\u003c\/td\u003e\n\u003ctd\u003eSD1-2HP2PS\u003c\/td\u003e\n\u003ctd\u003e232 ft\u003c\/td\u003e\n\u003ctd\u003e367 ft\u003c\/td\u003e\n\u003ctd\u003e56 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e24150L2-APT\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6630-731\u003c\/td\u003e\n\u003ctd\u003e1 1\/2\u003c\/td\u003e\n\u003ctd\u003e230V 1Ph 2-Wire\u003c\/td\u003e\n\u003ctd\u003eTransducer\u003c\/td\u003e\n\u003ctd\u003eSD1-2HP2\u003c\/td\u003e\n\u003ctd\u003e232 ft\u003c\/td\u003e\n\u003ctd\u003e367 ft\u003c\/td\u003e\n\u003ctd\u003e56 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e24150L3-APS\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6630-781\u003c\/td\u003e\n\u003ctd\u003e1 1\/2\u003c\/td\u003e\n\u003ctd\u003e230V 1Ph 3-Wire\u003c\/td\u003e\n\u003ctd\u003ePressure Switch\u003c\/td\u003e\n\u003ctd\u003eSD1-2HP2PS\u003c\/td\u003e\n\u003ctd\u003e232 ft\u003c\/td\u003e\n\u003ctd\u003e367 ft\u003c\/td\u003e\n\u003ctd\u003e55 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e24150L3-APT\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6630-775\u003c\/td\u003e\n\u003ctd\u003e1 1\/2\u003c\/td\u003e\n\u003ctd\u003e230V 1Ph 3-Wire\u003c\/td\u003e\n\u003ctd\u003eTransducer\u003c\/td\u003e\n\u003ctd\u003eSD1-2HP2\u003c\/td\u003e\n\u003ctd\u003e232 ft\u003c\/td\u003e\n\u003ctd\u003e367 ft\u003c\/td\u003e\n\u003ctd\u003e55 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e24150L3Z-APT\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6630-858\u003c\/td\u003e\n\u003ctd\u003e1 1\/2\u003c\/td\u003e\n\u003ctd\u003e230V 3Ph\u003c\/td\u003e\n\u003ctd\u003eTransducer\u003c\/td\u003e\n\u003ctd\u003eSD3-2HP2\u003c\/td\u003e\n\u003ctd\u003e232 ft\u003c\/td\u003e\n\u003ctd\u003e367 ft\u003c\/td\u003e\n\u003ctd\u003e48 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e24200L3-APS\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6630-791\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e230V 1Ph 3-Wire\u003c\/td\u003e\n\u003ctd\u003ePressure Switch\u003c\/td\u003e\n\u003ctd\u003eSD1-2HP2PS\u003c\/td\u003e\n\u003ctd\u003e331 ft\u003c\/td\u003e\n\u003ctd\u003e519 ft\u003c\/td\u003e\n\u003ctd\u003e57 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e24200L3-APT\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6630-786\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e230V 1Ph 3-Wire\u003c\/td\u003e\n\u003ctd\u003eTransducer\u003c\/td\u003e\n\u003ctd\u003eSD1-2HP2\u003c\/td\u003e\n\u003ctd\u003e331 ft\u003c\/td\u003e\n\u003ctd\u003e519 ft\u003c\/td\u003e\n\u003ctd\u003e57 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e24200L3Z-APT\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6630-796\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e230V 3Ph\u003c\/td\u003e\n\u003ctd\u003eTransducer\u003c\/td\u003e\n\u003ctd\u003eSD3-2HP2\u003c\/td\u003e\n\u003ctd\u003e331 ft\u003c\/td\u003e\n\u003ctd\u003e519 ft\u003c\/td\u003e\n\u003ctd\u003e55 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e24300L3Z-APT\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6630-800\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003ctd\u003e230V 3Ph\u003c\/td\u003e\n\u003ctd\u003eTransducer\u003c\/td\u003e\n\u003ctd\u003eSD3-3HP2\u003c\/td\u003e\n\u003ctd\u003e411 ft\u003c\/td\u003e\n\u003ctd\u003e645 ft\u003c\/td\u003e\n\u003ctd\u003e66 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e24500L3Z-APT\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6630-804\u003c\/td\u003e\n\u003ctd\u003e5\u003c\/td\u003e\n\u003ctd\u003e230V 3Ph\u003c\/td\u003e\n\u003ctd\u003eTransducer\u003c\/td\u003e\n\u003ctd\u003eSD3-5HP2\u003c\/td\u003e\n\u003ctd\u003e700 ft\u003c\/td\u003e\n\u003ctd\u003e1084 ft\u003c\/td\u003e\n\u003ctd\u003e86 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"font-size:12.5px;color:#9B9EA3;margin-top:8px;line-height:1.55\"\u003eHead at 15 GPM is read from the published AutoPAC curve (Pumps by Baker catalog (Sept 2025, rev 3\/26), p. 152), digitized and rounded down. Shut-off head as printed. Drive per the compatibility table on p. 141 (1 1\/2 HP three-phase builds use the SD3-2HP2). Sources: Pumps by Baker catalog (Sept 2025, rev 3\/26), pp. 141-143 and 152; Baker Pumps and Accessories price list, effective 7\/1\/2026.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eShared Specifications\u003c\/div\u003e\n\u003cdiv class=\"gs-lead\"\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eIncluded\u003c\/td\u003e\n\u003ctd\u003ePump end, Baker 4 in motor, AutoDRIVE drive, and pressure switch or transducer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDischarge\u003c\/td\u003e\n\u003ctd\u003e1 1\/4 in NPT (female)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCheck valve\u003c\/td\u003e\n\u003ctd\u003eBuilt in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply\u003c\/td\u003e\n\u003ctd\u003e230V single-phase, 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor\u003c\/td\u003e\n\u003ctd\u003eBaker 4 in submersible motor, matched to the pump end horsepower\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePump diameter\u003c\/td\u003e\n\u003ctd\u003e3 3\/4 in with cable guard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrive enclosure\u003c\/td\u003e\n\u003ctd\u003eNEMA Type 3R steel, 12.25 x 9.25 x 4.68 in, 13 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrive operating temperature\u003c\/td\u003e\n\u003ctd\u003e-4 to 122°F; SD3-5HP2 rated to 104°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrive efficiency\u003c\/td\u003e\n\u003ctd\u003e95%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertification (pump)\u003c\/td\u003e\n\u003ctd\u003eDrinking Water ANSI\/NSF 61\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApp connection\u003c\/td\u003e\n\u003ctd\u003eNone; set up on the drive display\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"font-size:12.5px;color:#9B9EA3;margin-top:8px;line-height:1.55\"\u003eSource: Pumps by Baker catalog (Sept 2025, rev 3\/26), pp. 131-133 and 141-143.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003ePerformance — Will It Do What You Need?\u003c\/div\u003e\n\u003cdiv class=\"gs-lead\"\u003e\n\u003cp\u003e\u003cstrong\u003eTotal head\u003c\/strong\u003e is everything the pump lifts against: the vertical lift from the pumping water level to the discharge, the pressure you set on the drive (2.31 ft for every PSI), and friction in the drop pipe. The drive slows the pump when demand falls, so the curve below is the most the pump delivers at full speed.\u003c\/p\u003e\n\u003cp style=\"margin-bottom:4px\"\u003e\u003cstrong\u003eTotal head in feet, by flow in GPM, at full speed\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eHP (stages)\u003c\/th\u003e\n\u003cth\u003e0\u003c\/th\u003e\n\u003cth\u003e2.5\u003c\/th\u003e\n\u003cth\u003e5\u003c\/th\u003e\n\u003cth\u003e7.5\u003c\/th\u003e\n\u003cth\u003e10\u003c\/th\u003e\n\u003cth\u003e12.5\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003e15\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e17.5\u003c\/th\u003e\n\u003cth\u003e20\u003c\/th\u003e\n\u003cth\u003e22.5\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e1\/2 HP (5)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e149\u003c\/td\u003e\n\u003ctd\u003e147\u003c\/td\u003e\n\u003ctd\u003e142\u003c\/td\u003e\n\u003ctd\u003e135\u003c\/td\u003e\n\u003ctd\u003e124\u003c\/td\u003e\n\u003ctd\u003e110\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e93\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e73\u003c\/td\u003e\n\u003ctd\u003e50\u003c\/td\u003e\n\u003ctd\u003e23\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e3\/4 HP (7)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e206\u003c\/td\u003e\n\u003ctd\u003e206\u003c\/td\u003e\n\u003ctd\u003e200\u003c\/td\u003e\n\u003ctd\u003e190\u003c\/td\u003e\n\u003ctd\u003e175\u003c\/td\u003e\n\u003ctd\u003e156\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e132\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e104\u003c\/td\u003e\n\u003ctd\u003e71\u003c\/td\u003e\n\u003ctd\u003e34\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e1 HP (10)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e296\u003c\/td\u003e\n\u003ctd\u003e294\u003c\/td\u003e\n\u003ctd\u003e286\u003c\/td\u003e\n\u003ctd\u003e271\u003c\/td\u003e\n\u003ctd\u003e251\u003c\/td\u003e\n\u003ctd\u003e223\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e190\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e150\u003c\/td\u003e\n\u003ctd\u003e103\u003c\/td\u003e\n\u003ctd\u003e51\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e1 1\/2 HP (12)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e365\u003c\/td\u003e\n\u003ctd\u003e361\u003c\/td\u003e\n\u003ctd\u003e351\u003c\/td\u003e\n\u003ctd\u003e333\u003c\/td\u003e\n\u003ctd\u003e307\u003c\/td\u003e\n\u003ctd\u003e274\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e232\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e183\u003c\/td\u003e\n\u003ctd\u003e126\u003c\/td\u003e\n\u003ctd\u003e62\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e2 HP (17)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e518\u003c\/td\u003e\n\u003ctd\u003e514\u003c\/td\u003e\n\u003ctd\u003e499\u003c\/td\u003e\n\u003ctd\u003e473\u003c\/td\u003e\n\u003ctd\u003e437\u003c\/td\u003e\n\u003ctd\u003e389\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e331\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e261\u003c\/td\u003e\n\u003ctd\u003e181\u003c\/td\u003e\n\u003ctd\u003e89\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e3 HP (21)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e644\u003c\/td\u003e\n\u003ctd\u003e635\u003c\/td\u003e\n\u003ctd\u003e615\u003c\/td\u003e\n\u003ctd\u003e583\u003c\/td\u003e\n\u003ctd\u003e539\u003c\/td\u003e\n\u003ctd\u003e482\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e411\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e326\u003c\/td\u003e\n\u003ctd\u003e226\u003c\/td\u003e\n\u003ctd\u003e110\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e5 HP (35)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1084\u003c\/td\u003e\n\u003ctd\u003e1062\u003c\/td\u003e\n\u003ctd\u003e1026\u003c\/td\u003e\n\u003ctd\u003e974\u003c\/td\u003e\n\u003ctd\u003e904\u003c\/td\u003e\n\u003ctd\u003e814\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e700\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e559\u003c\/td\u003e\n\u003ctd\u003e389\u003c\/td\u003e\n\u003ctd\u003e188\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"font-size:12.5px;color:#9B9EA3;margin-top:6px;line-height:1.55\"\u003eDigitized from the published AutoPAC curve in the Pumps by Baker catalog (Sept 2025, rev 3\/26), p. 152, and rounded down. Rated flow (15 GPM) in bold. Zero flow is the shut-off point, a ceiling rather than a working point; — marks flows past the end of that curve.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBest operating range:\u003c\/strong\u003e the published curve shades the most efficient operating range; the catalog prints no figures for it. The curve is in the image gallery.\u003c\/p\u003e\n\u003cdiv style=\"display:flex;flex-wrap:wrap;gap:10px;margin:22px 0 4px\"\u003e\n\u003ca href=\"\/pages\/submersible-well-pump-sizing-calculator\" style=\"flex:1 1 200px;text-align:center;display:block;background:#B3122A;color:#ffffff;font-family:Arial Black,Arial,sans-serif;font-size:12px;text-transform:uppercase;letter-spacing:1.2px;padding:11px 18px;text-decoration:none\"\u003eSubmersible Calculator\u003c\/a\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eBefore You Buy — The Limits That Decide the Fit\u003c\/div\u003e\n\u003cdiv class=\"gs-lead\"\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply\u003c\/td\u003e\n\u003ctd\u003e230V single-phase for every build, from a circuit breaker sized per the table below\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure transducer\u003c\/td\u003e\n\u003ctd\u003eMust be installed upright and vertical (manufacturer note)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrive location\u003c\/td\u003e\n\u003ctd\u003eNEMA 3R enclosure, outdoors or indoors; rated to 122°F (104°F for SD3-5HP2); derate above 5500 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor cooling\u003c\/td\u003e\n\u003ctd\u003e1.0 ft\/sec of water flow past the motor at 95°F; motor rated to 95°F water\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWell size\u003c\/td\u003e\n\u003ctd\u003e4 in casing and larger\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePairing\u003c\/td\u003e\n\u003ctd\u003eOne pump and one drive per well\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"margin:14px 0 4px\"\u003e\u003cstrong\u003eBreaker sizing by motor HP (manufacturer recommendation)\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSupply\u003c\/th\u003e\n\u003cth\u003eMotor HP\u003c\/th\u003e\n\u003cth\u003eInput Current\u003c\/th\u003e\n\u003cth\u003eFuse \/ Breaker\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e230V\u003c\/td\u003e\n\u003ctd\u003e1\/2\u003c\/td\u003e\n\u003ctd\u003e6 A\u003c\/td\u003e\n\u003ctd\u003e10 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e230V\u003c\/td\u003e\n\u003ctd\u003e3\/4\u003c\/td\u003e\n\u003ctd\u003e9 A\u003c\/td\u003e\n\u003ctd\u003e15 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e230V\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003ctd\u003e14 A\u003c\/td\u003e\n\u003ctd\u003e20 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e230V\u003c\/td\u003e\n\u003ctd\u003e1 1\/2\u003c\/td\u003e\n\u003ctd\u003e18 A\u003c\/td\u003e\n\u003ctd\u003e25 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e230V\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e28 A\u003c\/td\u003e\n\u003ctd\u003e35 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e230V\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e20 A\u003c\/td\u003e\n\u003ctd\u003e25 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e230V\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003ctd\u003e30 A\u003c\/td\u003e\n\u003ctd\u003e40 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e230V\u003c\/td\u003e\n\u003ctd\u003e5\u003c\/td\u003e\n\u003ctd\u003e42 A\u003c\/td\u003e\n\u003ctd\u003e55 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"font-size:12.5px;color:#9B9EA3;margin-top:8px;line-height:1.55\"\u003eSource: Pumps by Baker catalog (Sept 2025, rev 3\/26), p. 131.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eMaterials of Construction (Pump)\u003c\/div\u003e\n\u003cdiv class=\"gs-lead\"\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eDischarge head\u003c\/td\u003e\n\u003ctd\u003eStainless steel 304, 1 1\/4 in NPT discharge\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor adapter\u003c\/td\u003e\n\u003ctd\u003eStainless steel 304, NEMA standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCheck valve\u003c\/td\u003e\n\u003ctd\u003eStainless steel 304\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExternal shell\u003c\/td\u003e\n\u003ctd\u003eStainless steel 304, polished\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eImpellers\u003c\/td\u003e\n\u003ctd\u003eNoryl\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiffusers\u003c\/td\u003e\n\u003ctd\u003ePolycarbonate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBearing\u003c\/td\u003e\n\u003ctd\u003ePolyacetal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShaft coupling\u003c\/td\u003e\n\u003ctd\u003eStainless steel 304, NEMA standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStrainer\u003c\/td\u003e\n\u003ctd\u003eThermoplastic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShaft\u003c\/td\u003e\n\u003ctd\u003eStainless steel 304\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable guard\u003c\/td\u003e\n\u003ctd\u003eStainless steel 304\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"font-size:12.5px;color:#9B9EA3;margin-top:8px;line-height:1.55\"\u003eSource: Pumps by Baker catalog (Sept 2025, rev 3\/26), pp. 65-66.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eService Parts\u003c\/div\u003e\n\u003cdiv class=\"gs-lead\"\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003ePart\u003c\/th\u003e\n\u003cth\u003ePart No.\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutoDRIVE pressure transducer with 10 ft wire\u003c\/td\u003e\n\u003ctd\u003e6619-028\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutoDRIVE pressure switch with wire\u003c\/td\u003e\n\u003ctd\u003e6619-029\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutoDRIVE keypad\u003c\/td\u003e\n\u003ctd\u003e6619-030\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"font-size:12.5px;color:#9B9EA3;margin-top:8px;line-height:1.55\"\u003eSource: Pumps by Baker catalog (Sept 2025, rev 3\/26), pp. 142-143.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"gs-contact\"\u003eFor engineering-led sizing and selection support or a factory submittal, email \u003ca href=\"mailto:sales@watermainsupply.com\"\u003esales@watermainsupply.com\u003c\/a\u003e or call \u003ca href=\"tel:18885104036\"\u003e1-888.510.4036\u003c\/a\u003e.\u003cbr\u003e© Watermain Supply — A division of E4 Industrial LLC\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch5\u003eData Sheet\u003c\/h5\u003e\n\u003cdiv class=\"gs\"\u003e\n\u003cdiv class=\"gs-dl\"\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0264\/1913\/4527\/files\/AutoPac_Guide.pdf?v=1772502299\" target=\"_blank\" rel=\"noopener\"\u003ePumps by Baker AutoPac Guide\u003c\/a\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch5\u003eVideos\u003c\/h5\u003e\n\u003cdiv class=\"gs\"\u003e\u003cdiv class=\"gs-sec\" style=\"margin-top:6px\"\u003e\n\u003cp style=\"font-size:13px;color:#9B9EA3\"\u003eProduct videos are being added to this listing. For a walkthrough in the meantime, email sales@watermainsupply.com.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003c!-- \/TABS --\u003e","brand":"A.Y. McDonald","offers":[{"title":"1\/2 HP - 4 in Motor \/ 230V 1Ph 2-Wire \/ Switch - 24050L2-APS - 93 ft at 15 GPM","offer_id":46602932453551,"sku":"6630-704","price":1968.9,"currency_code":"USD","in_stock":true},{"title":"1\/2 HP - 4 in Motor \/ 230V 1Ph 2-Wire \/ Transducer - 24050L2-APT - 93 ft at 15 GPM","offer_id":46602932584623,"sku":"6630-699","price":2146.78,"currency_code":"USD","in_stock":true},{"title":"1\/2 HP - 4 in Motor \/ 230V 1Ph 3-Wire \/ Switch - 24050L3-APS - 93 ft at 15 GPM","offer_id":46602932715695,"sku":"6630-748","price":1882.53,"currency_code":"USD","in_stock":true},{"title":"1\/2 HP - 4 in Motor \/ 230V 1Ph 3-Wire \/ Transducer - 24050L3-APT - 93 ft at 15 GPM","offer_id":46602932879535,"sku":"6630-743","price":2061.41,"currency_code":"USD","in_stock":true},{"title":"3\/4 HP - 4 in Motor \/ 230V 1Ph 2-Wire \/ Switch - 24075L2-APS - 132 ft at 15 GPM","offer_id":46602932486319,"sku":"6630-714","price":2124.8,"currency_code":"USD","in_stock":true},{"title":"3\/4 HP - 4 in Motor \/ 230V 1Ph 2-Wire \/ Transducer - 24075L2-APT - 132 ft at 15 GPM","offer_id":46602932617391,"sku":"6630-709","price":2303.7,"currency_code":"USD","in_stock":true},{"title":"3\/4 HP - 4 in Motor \/ 230V 1Ph 3-Wire \/ Switch - 24075L3-APS - 132 ft at 15 GPM","offer_id":46602932748463,"sku":"6630-758","price":1878.39,"currency_code":"USD","in_stock":true},{"title":"3\/4 HP - 4 in Motor \/ 230V 1Ph 3-Wire \/ Transducer - 24075L3-APT - 132 ft at 15 GPM","offer_id":46602932912303,"sku":"6630-753","price":2188.69,"currency_code":"USD","in_stock":true},{"title":"1 HP - 4 in Motor \/ 230V 1Ph 2-Wire \/ Switch - 24100L2-APS - 190 ft at 15 GPM","offer_id":46602932519087,"sku":"6630-725","price":2218.84,"currency_code":"USD","in_stock":true},{"title":"1 HP - 4 in Motor \/ 230V 1Ph 2-Wire \/ Transducer - 24100L2-APT - 190 ft at 15 GPM","offer_id":46602932650159,"sku":"6630-719","price":2398.26,"currency_code":"USD","in_stock":true},{"title":"1 HP - 4 in Motor \/ 230V 1Ph 3-Wire \/ Switch - 24100L3-APS - 190 ft at 15 GPM","offer_id":46602932781231,"sku":"6630-769","price":2078.8,"currency_code":"USD","in_stock":true},{"title":"1 HP - 4 in Motor \/ 230V 1Ph 3-Wire \/ Transducer - 24100L3-APT - 190 ft at 15 GPM","offer_id":46602932945071,"sku":"6630-763","price":2257.19,"currency_code":"USD","in_stock":true},{"title":"1 1\/2 HP - 4 in Motor \/ 230V 1Ph 2-Wire \/ Switch - 24150L2-APS - 232 ft at 15 GPM","offer_id":46602932551855,"sku":"6630-737","price":2362.0,"currency_code":"USD","in_stock":true},{"title":"1 1\/2 HP - 4 in Motor \/ 230V 1Ph 2-Wire \/ Transducer - 24150L2-APT - 232 ft at 15 GPM","offer_id":46602932682927,"sku":"6630-731","price":2539.88,"currency_code":"USD","in_stock":true},{"title":"1 1\/2 HP - 4 in Motor \/ 230V 1Ph 3-Wire \/ Switch - 24150L3-APS - 232 ft at 15 GPM","offer_id":46602932813999,"sku":"6630-781","price":2178.0,"currency_code":"USD","in_stock":true},{"title":"1 1\/2 HP - 4 in Motor \/ 230V 1Ph 3-Wire \/ Transducer - 24150L3-APT - 232 ft at 15 GPM","offer_id":46602932977839,"sku":"6630-775","price":2355.86,"currency_code":"USD","in_stock":true},{"title":"1 1\/2 HP - 4 in Motor \/ 230V 3Ph \/ Transducer - 24150L3Z-APT - 232 ft at 15 GPM","offer_id":46602933043375,"sku":"6630-858","price":2578.68,"currency_code":"USD","in_stock":true},{"title":"2 HP - 4 in Motor \/ 230V 1Ph 3-Wire \/ Switch - 24200L3-APS - 331 ft at 15 GPM","offer_id":46602932846767,"sku":"6630-791","price":2352.29,"currency_code":"USD","in_stock":true},{"title":"2 HP - 4 in Motor \/ 230V 1Ph 3-Wire \/ Transducer - 24200L3-APT - 331 ft at 15 GPM","offer_id":46602933010607,"sku":"6630-786","price":2531.19,"currency_code":"USD","in_stock":true},{"title":"2 HP - 4 in Motor \/ 230V 3Ph \/ Transducer - 24200L3Z-APT - 331 ft at 15 GPM","offer_id":46602933076143,"sku":"6630-796","price":2748.93,"currency_code":"USD","in_stock":true},{"title":"3 HP - 4 in Motor \/ 230V 3Ph \/ Transducer - 24300L3Z-APT - 411 ft at 15 GPM","offer_id":46602933108911,"sku":"6630-800","price":3402.66,"currency_code":"USD","in_stock":true},{"title":"5 HP - 4 in Motor \/ 230V 3Ph \/ Transducer - 24500L3Z-APT - 700 ft at 15 GPM","offer_id":46602933141679,"sku":"6630-804","price":5285.23,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0264\/1913\/4527\/files\/AutoPac_f897a723-43b9-4be9-913e-f2bf14bf750c.png?v=1772502611"},{"product_id":"baker-autopac-p-20-gpm-24000-series","title":"A.Y. McDonald AutoPAC P - 20 GPM 24000 Constant Pressure Pump","description":"\u003c!-- TABS --\u003e\n\u003ch5\u003eDescription\u003c\/h5\u003e\n\u003cdiv class=\"gs\"\u003e\n\u003cdiv class=\"gs-head\"\u003e\n\u003cdiv class=\"gs-eyebrow\"\u003eA.Y. McDonald · Constant Pressure Pump System\u003c\/div\u003e\n\u003cdiv class=\"gs-title\"\u003eAutoPAC P - 20 GPM, 24000 Series\u003c\/div\u003e\n\u003cdiv class=\"gs-sub\"\u003eBaker stainless steel 4 in submersible pump, motor and AutoDRIVE constant pressure drive, 1\/2 to 5 HP, 22 builds.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"gs-badges\"\u003e\n\u003cdiv class=\"gs-badge\" style=\"background:#B3122A;color:#FFFFFF;border-color:#B3122A\"\u003e91-619 ft at 20 GPM\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003e1\/2-5 HP\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003e230V Single-Phase Supply\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003eAutoDRIVE Constant Pressure VFD\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003ePressure Switch or Transducer Control\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003e925 ft Max Head (Shut-off)\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003e1 1\/4 in NPT Discharge\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003eNEMA 3R Drive Enclosure\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003eDrinking Water ANSI\/NSF 61\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003e39-86 lb Weight\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background:#FFFFFF;border:1px solid #C7CBD1;border-top:3px solid #B3122A;padding:12px 16px 12px;margin:16px 0 4px;font-size:13.5px;line-height:1.55;color:#4A4A4F\"\u003e\n\u003cdiv style=\"font-family:Arial Black,Arial,sans-serif;font-size:11px;letter-spacing:1.2px;text-transform:uppercase;color:#B3122A;margin-bottom:8px\"\u003eWhat Ships and What It Needs to Run\u003c\/div\u003e\n\u003cp style=\"margin:0 0 6px\"\u003e\u003cstrong style=\"color:#B3122A\"\u003eIncluded:\u003c\/strong\u003e the pump end and Baker 4 in motor, assembled, with the AutoDRIVE constant pressure drive matched to the motor, and the pressure switch (APS models) or pressure transducer with 10 ft wire (APT models). The drive model for each build is in the Models table.\u003c\/p\u003e\n\u003cp style=\"margin:0 0 6px\"\u003e\u003cstrong style=\"color:#B3122A\"\u003ePower:\u003c\/strong\u003e 230V single-phase supply from a circuit breaker for every build; the three-phase builds take single-phase power and the drive makes three-phase for the motor. Breaker sizes are under Before You Buy.\u003c\/p\u003e\n\u003cp style=\"margin:0\"\u003e\u003cstrong style=\"color:#B3122A\"\u003eSized at install:\u003c\/strong\u003e drop cable, splice kit and the pressure relief valve shown in the manufacturer’s installation diagram.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eOverview\u003c\/div\u003e\n\u003cdiv class=\"gs-lead\"\u003e\n\u003cp\u003eThe AutoPAC is Baker’s constant pressure well package: a 24000 Series 4 in submersible pump, a Baker motor of the same horsepower, and the AutoDRIVE variable frequency drive. The drive holds a set pressure by changing the pump speed, which allows a smaller pressure tank and a quick, simple installation; setup takes 5 steps or less on the drive’s backlit display.\u003c\/p\u003e\n\u003cp\u003eThis listing is the \u003cstrong\u003eP - 20 GPM\u003c\/strong\u003e class: 1\/2 to 5 HP, with pressure switch and transducer control. The AutoDRIVE is American made and housed in a NEMA 3R steel enclosure rated for outdoor use.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background:#E1E3E6;border-left:3px solid #B8BDC4;padding:8px 14px;font-size:11.5px;color:#4A4A4F;margin-top:14px;line-height:1.5\"\u003eGenuine A.Y. McDonald equipment, factory-new in original packaging — sold and supported by Watermain Supply, an independent industrial supplier. Watermain Supply is an Authorized Stocking A.Y. McDonald and Baker Water Systems Distributor.\u003c\/div\u003e\n\u003cdiv style=\"background:#fff;border-left:5px solid #B3122A;padding:15px 18px;margin-top:12px\"\u003e\n\u003cdiv style=\"font-family:Arial Black,Arial,sans-serif;font-size:15px;color:#B3122A;text-transform:uppercase;letter-spacing:1px;margin-bottom:6px\"\u003eA.Y. McDonald Warranty\u003c\/div\u003e\n\u003cp style=\"margin:0;font-size:13.5px;color:#4A4A4F;line-height:1.55\"\u003ePump and motor: covered for \u003cstrong\u003e5 years from the date of manufacture in potable water applications\u003c\/strong\u003e, and 3 years from the date of manufacture in other applications, under A.Y. McDonald’s published terms for Baker submersible motors and assembled submersible pumps. The AutoDRIVE and pressure control fall under A.Y. McDonald’s standard limited warranty: 2 years from the date of manufacture or 1 year from installation, whichever comes first.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eRoom to Grow\u003c\/div\u003e\n\u003cdiv class=\"gs-lead\"\u003e\n\u003cp\u003eOne pump and one drive per well. Need more head later? Step up in horsepower within the P - 20 GPM class; the drive model changes with the motor (see the Models table). Need more flow? Move to a higher flow class of the AutoPAC 24000 Series; every class uses the same 1 1\/4 in NPT discharge.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eModels \u0026amp; Ratings (60 Hz)\u003c\/div\u003e\n\u003cdiv class=\"gs-lead\"\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003cth\u003ePart No.\u003c\/th\u003e\n\u003cth\u003eHP\u003c\/th\u003e\n\u003cth\u003eMotor\u003c\/th\u003e\n\u003cth\u003eControl\u003c\/th\u003e\n\u003cth\u003eAutoDRIVE\u003c\/th\u003e\n\u003cth\u003eHead at 20 GPM\u003c\/th\u003e\n\u003cth\u003eShut-off Head\u003c\/th\u003e\n\u003cth\u003eWeight\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e24050P2-APS\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6630-705\u003c\/td\u003e\n\u003ctd\u003e1\/2\u003c\/td\u003e\n\u003ctd\u003e230V 1Ph 2-Wire\u003c\/td\u003e\n\u003ctd\u003ePressure Switch\u003c\/td\u003e\n\u003ctd\u003eSD1-2HP2PS\u003c\/td\u003e\n\u003ctd\u003e91 ft\u003c\/td\u003e\n\u003ctd\u003e145 ft\u003c\/td\u003e\n\u003ctd\u003e41 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e24050P2-APT\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6630-700\u003c\/td\u003e\n\u003ctd\u003e1\/2\u003c\/td\u003e\n\u003ctd\u003e230V 1Ph 2-Wire\u003c\/td\u003e\n\u003ctd\u003eTransducer\u003c\/td\u003e\n\u003ctd\u003eSD1-2HP2\u003c\/td\u003e\n\u003ctd\u003e91 ft\u003c\/td\u003e\n\u003ctd\u003e145 ft\u003c\/td\u003e\n\u003ctd\u003e41 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e24050P3-APS\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6630-749\u003c\/td\u003e\n\u003ctd\u003e1\/2\u003c\/td\u003e\n\u003ctd\u003e230V 1Ph 3-Wire\u003c\/td\u003e\n\u003ctd\u003ePressure Switch\u003c\/td\u003e\n\u003ctd\u003eSD1-2HP2PS\u003c\/td\u003e\n\u003ctd\u003e91 ft\u003c\/td\u003e\n\u003ctd\u003e145 ft\u003c\/td\u003e\n\u003ctd\u003e39 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e24050P3-APT\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6630-744\u003c\/td\u003e\n\u003ctd\u003e1\/2\u003c\/td\u003e\n\u003ctd\u003e230V 1Ph 3-Wire\u003c\/td\u003e\n\u003ctd\u003eTransducer\u003c\/td\u003e\n\u003ctd\u003eSD1-2HP2\u003c\/td\u003e\n\u003ctd\u003e91 ft\u003c\/td\u003e\n\u003ctd\u003e145 ft\u003c\/td\u003e\n\u003ctd\u003e39 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e24075P2-APS\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6630-715\u003c\/td\u003e\n\u003ctd\u003e3\/4\u003c\/td\u003e\n\u003ctd\u003e230V 1Ph 2-Wire\u003c\/td\u003e\n\u003ctd\u003ePressure Switch\u003c\/td\u003e\n\u003ctd\u003eSD1-2HP2PS\u003c\/td\u003e\n\u003ctd\u003e120 ft\u003c\/td\u003e\n\u003ctd\u003e182 ft\u003c\/td\u003e\n\u003ctd\u003e43 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e24075P2-APT\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6630-710\u003c\/td\u003e\n\u003ctd\u003e3\/4\u003c\/td\u003e\n\u003ctd\u003e230V 1Ph 2-Wire\u003c\/td\u003e\n\u003ctd\u003eTransducer\u003c\/td\u003e\n\u003ctd\u003eSD1-2HP2\u003c\/td\u003e\n\u003ctd\u003e120 ft\u003c\/td\u003e\n\u003ctd\u003e182 ft\u003c\/td\u003e\n\u003ctd\u003e43 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e24075P3-APS\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6630-759\u003c\/td\u003e\n\u003ctd\u003e3\/4\u003c\/td\u003e\n\u003ctd\u003e230V 1Ph 3-Wire\u003c\/td\u003e\n\u003ctd\u003ePressure Switch\u003c\/td\u003e\n\u003ctd\u003eSD1-2HP2PS\u003c\/td\u003e\n\u003ctd\u003e120 ft\u003c\/td\u003e\n\u003ctd\u003e182 ft\u003c\/td\u003e\n\u003ctd\u003e40 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e24075P3-APT\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6630-754\u003c\/td\u003e\n\u003ctd\u003e3\/4\u003c\/td\u003e\n\u003ctd\u003e230V 1Ph 3-Wire\u003c\/td\u003e\n\u003ctd\u003eTransducer\u003c\/td\u003e\n\u003ctd\u003eSD1-2HP2\u003c\/td\u003e\n\u003ctd\u003e120 ft\u003c\/td\u003e\n\u003ctd\u003e182 ft\u003c\/td\u003e\n\u003ctd\u003e40 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e24100P2-APS\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6630-726\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003ctd\u003e230V 1Ph 2-Wire\u003c\/td\u003e\n\u003ctd\u003ePressure Switch\u003c\/td\u003e\n\u003ctd\u003eSD1-2HP2PS\u003c\/td\u003e\n\u003ctd\u003e160 ft\u003c\/td\u003e\n\u003ctd\u003e243 ft\u003c\/td\u003e\n\u003ctd\u003e49 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e24100P2-APT\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6630-720\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003ctd\u003e230V 1Ph 2-Wire\u003c\/td\u003e\n\u003ctd\u003eTransducer\u003c\/td\u003e\n\u003ctd\u003eSD1-2HP2\u003c\/td\u003e\n\u003ctd\u003e160 ft\u003c\/td\u003e\n\u003ctd\u003e243 ft\u003c\/td\u003e\n\u003ctd\u003e49 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e24100P3-APS\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6630-770\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003ctd\u003e230V 1Ph 3-Wire\u003c\/td\u003e\n\u003ctd\u003ePressure Switch\u003c\/td\u003e\n\u003ctd\u003eSD1-2HP2PS\u003c\/td\u003e\n\u003ctd\u003e160 ft\u003c\/td\u003e\n\u003ctd\u003e243 ft\u003c\/td\u003e\n\u003ctd\u003e48 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e24100P3-APT\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6630-764\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003ctd\u003e230V 1Ph 3-Wire\u003c\/td\u003e\n\u003ctd\u003eTransducer\u003c\/td\u003e\n\u003ctd\u003eSD1-2HP2\u003c\/td\u003e\n\u003ctd\u003e160 ft\u003c\/td\u003e\n\u003ctd\u003e243 ft\u003c\/td\u003e\n\u003ctd\u003e48 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e24150P2-APS\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6630-738\u003c\/td\u003e\n\u003ctd\u003e1 1\/2\u003c\/td\u003e\n\u003ctd\u003e230V 1Ph 2-Wire\u003c\/td\u003e\n\u003ctd\u003ePressure Switch\u003c\/td\u003e\n\u003ctd\u003eSD1-2HP2PS\u003c\/td\u003e\n\u003ctd\u003e228 ft\u003c\/td\u003e\n\u003ctd\u003e339 ft\u003c\/td\u003e\n\u003ctd\u003e56 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e24150P2-APT\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6630-732\u003c\/td\u003e\n\u003ctd\u003e1 1\/2\u003c\/td\u003e\n\u003ctd\u003e230V 1Ph 2-Wire\u003c\/td\u003e\n\u003ctd\u003eTransducer\u003c\/td\u003e\n\u003ctd\u003eSD1-2HP2\u003c\/td\u003e\n\u003ctd\u003e228 ft\u003c\/td\u003e\n\u003ctd\u003e339 ft\u003c\/td\u003e\n\u003ctd\u003e56 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e24150P3-APS\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6630-782\u003c\/td\u003e\n\u003ctd\u003e1 1\/2\u003c\/td\u003e\n\u003ctd\u003e230V 1Ph 3-Wire\u003c\/td\u003e\n\u003ctd\u003ePressure Switch\u003c\/td\u003e\n\u003ctd\u003eSD1-2HP2PS\u003c\/td\u003e\n\u003ctd\u003e228 ft\u003c\/td\u003e\n\u003ctd\u003e339 ft\u003c\/td\u003e\n\u003ctd\u003e55 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e24150P3-APT\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6630-776\u003c\/td\u003e\n\u003ctd\u003e1 1\/2\u003c\/td\u003e\n\u003ctd\u003e230V 1Ph 3-Wire\u003c\/td\u003e\n\u003ctd\u003eTransducer\u003c\/td\u003e\n\u003ctd\u003eSD1-2HP2\u003c\/td\u003e\n\u003ctd\u003e228 ft\u003c\/td\u003e\n\u003ctd\u003e339 ft\u003c\/td\u003e\n\u003ctd\u003e55 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e24150P3Z-APT\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6630-859\u003c\/td\u003e\n\u003ctd\u003e1 1\/2\u003c\/td\u003e\n\u003ctd\u003e230V 3Ph\u003c\/td\u003e\n\u003ctd\u003eTransducer\u003c\/td\u003e\n\u003ctd\u003eSD3-2HP2\u003c\/td\u003e\n\u003ctd\u003e228 ft\u003c\/td\u003e\n\u003ctd\u003e339 ft\u003c\/td\u003e\n\u003ctd\u003e48 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e24200P3-APS\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6630-792\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e230V 1Ph 3-Wire\u003c\/td\u003e\n\u003ctd\u003ePressure Switch\u003c\/td\u003e\n\u003ctd\u003eSD1-2HP2PS\u003c\/td\u003e\n\u003ctd\u003e290 ft\u003c\/td\u003e\n\u003ctd\u003e432 ft\u003c\/td\u003e\n\u003ctd\u003e56 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e24200P3-APT\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6630-787\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e230V 1Ph 3-Wire\u003c\/td\u003e\n\u003ctd\u003eTransducer\u003c\/td\u003e\n\u003ctd\u003eSD1-2HP2\u003c\/td\u003e\n\u003ctd\u003e290 ft\u003c\/td\u003e\n\u003ctd\u003e432 ft\u003c\/td\u003e\n\u003ctd\u003e56 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e24200P3Z-APT\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6630-797\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e230V 3Ph\u003c\/td\u003e\n\u003ctd\u003eTransducer\u003c\/td\u003e\n\u003ctd\u003eSD3-2HP2\u003c\/td\u003e\n\u003ctd\u003e290 ft\u003c\/td\u003e\n\u003ctd\u003e432 ft\u003c\/td\u003e\n\u003ctd\u003e54 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e24300P3Z-APT\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6630-801\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003ctd\u003e230V 3Ph\u003c\/td\u003e\n\u003ctd\u003eTransducer\u003c\/td\u003e\n\u003ctd\u003eSD3-3HP2\u003c\/td\u003e\n\u003ctd\u003e393 ft\u003c\/td\u003e\n\u003ctd\u003e586 ft\u003c\/td\u003e\n\u003ctd\u003e67 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e24500P3Z-APT\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6630-805\u003c\/td\u003e\n\u003ctd\u003e5\u003c\/td\u003e\n\u003ctd\u003e230V 3Ph\u003c\/td\u003e\n\u003ctd\u003eTransducer\u003c\/td\u003e\n\u003ctd\u003eSD3-5HP2\u003c\/td\u003e\n\u003ctd\u003e619 ft\u003c\/td\u003e\n\u003ctd\u003e925 ft\u003c\/td\u003e\n\u003ctd\u003e86 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"font-size:12.5px;color:#9B9EA3;margin-top:8px;line-height:1.55\"\u003eHead at 20 GPM is read from the published AutoPAC curve (Pumps by Baker catalog (Sept 2025, rev 3\/26), p. 154), digitized and rounded down. Shut-off head as printed. Drive per the compatibility table on p. 141 (1 1\/2 HP three-phase builds use the SD3-2HP2). Sources: Pumps by Baker catalog (Sept 2025, rev 3\/26), pp. 141-143 and 154; Baker Pumps and Accessories price list, effective 7\/1\/2026.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eShared Specifications\u003c\/div\u003e\n\u003cdiv class=\"gs-lead\"\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eIncluded\u003c\/td\u003e\n\u003ctd\u003ePump end, Baker 4 in motor, AutoDRIVE drive, and pressure switch or transducer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDischarge\u003c\/td\u003e\n\u003ctd\u003e1 1\/4 in NPT (female)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCheck valve\u003c\/td\u003e\n\u003ctd\u003eBuilt in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply\u003c\/td\u003e\n\u003ctd\u003e230V single-phase, 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor\u003c\/td\u003e\n\u003ctd\u003eBaker 4 in submersible motor, matched to the pump end horsepower\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePump diameter\u003c\/td\u003e\n\u003ctd\u003e3 3\/4 in with cable guard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrive enclosure\u003c\/td\u003e\n\u003ctd\u003eNEMA Type 3R steel, 12.25 x 9.25 x 4.68 in, 13 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrive operating temperature\u003c\/td\u003e\n\u003ctd\u003e-4 to 122°F; SD3-5HP2 rated to 104°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrive efficiency\u003c\/td\u003e\n\u003ctd\u003e95%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertification (pump)\u003c\/td\u003e\n\u003ctd\u003eDrinking Water ANSI\/NSF 61\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApp connection\u003c\/td\u003e\n\u003ctd\u003eNone; set up on the drive display\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"font-size:12.5px;color:#9B9EA3;margin-top:8px;line-height:1.55\"\u003eSource: Pumps by Baker catalog (Sept 2025, rev 3\/26), pp. 131-133 and 141-143.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003ePerformance — Will It Do What You Need?\u003c\/div\u003e\n\u003cdiv class=\"gs-lead\"\u003e\n\u003cp\u003e\u003cstrong\u003eTotal head\u003c\/strong\u003e is everything the pump lifts against: the vertical lift from the pumping water level to the discharge, the pressure you set on the drive (2.31 ft for every PSI), and friction in the drop pipe. The drive slows the pump when demand falls, so the curve below is the most the pump delivers at full speed.\u003c\/p\u003e\n\u003cp style=\"margin-bottom:4px\"\u003e\u003cstrong\u003eTotal head in feet, by flow in GPM, at full speed\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eHP (stages)\u003c\/th\u003e\n\u003cth\u003e0\u003c\/th\u003e\n\u003cth\u003e5\u003c\/th\u003e\n\u003cth\u003e10\u003c\/th\u003e\n\u003cth\u003e15\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003e20\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e25\u003c\/th\u003e\n\u003cth\u003e30\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e1\/2 HP (5)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e146\u003c\/td\u003e\n\u003ctd\u003e141\u003c\/td\u003e\n\u003ctd\u003e130\u003c\/td\u003e\n\u003ctd\u003e114\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e91\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e63\u003c\/td\u003e\n\u003ctd\u003e28\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e3\/4 HP (6)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e183\u003c\/td\u003e\n\u003ctd\u003e178\u003c\/td\u003e\n\u003ctd\u003e166\u003c\/td\u003e\n\u003ctd\u003e147\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e120\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e87\u003c\/td\u003e\n\u003ctd\u003e47\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e1 HP (8)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e244\u003c\/td\u003e\n\u003ctd\u003e237\u003c\/td\u003e\n\u003ctd\u003e221\u003c\/td\u003e\n\u003ctd\u003e195\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e160\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e116\u003c\/td\u003e\n\u003ctd\u003e62\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e1 1\/2 HP (11)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e340\u003c\/td\u003e\n\u003ctd\u003e322\u003c\/td\u003e\n\u003ctd\u003e300\u003c\/td\u003e\n\u003ctd\u003e270\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e228\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e169\u003c\/td\u003e\n\u003ctd\u003e90\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e2 HP (14)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e433\u003c\/td\u003e\n\u003ctd\u003e410\u003c\/td\u003e\n\u003ctd\u003e382\u003c\/td\u003e\n\u003ctd\u003e344\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e290\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e215\u003c\/td\u003e\n\u003ctd\u003e114\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e3 HP (19)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e586\u003c\/td\u003e\n\u003ctd\u003e556\u003c\/td\u003e\n\u003ctd\u003e518\u003c\/td\u003e\n\u003ctd\u003e466\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e393\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e291\u003c\/td\u003e\n\u003ctd\u003e154\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e5 HP (30)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e924\u003c\/td\u003e\n\u003ctd\u003e877\u003c\/td\u003e\n\u003ctd\u003e817\u003c\/td\u003e\n\u003ctd\u003e735\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e619\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e459\u003c\/td\u003e\n\u003ctd\u003e243\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"font-size:12.5px;color:#9B9EA3;margin-top:6px;line-height:1.55\"\u003eDigitized from the published AutoPAC curve in the Pumps by Baker catalog (Sept 2025, rev 3\/26), p. 154, and rounded down. Rated flow (20 GPM) in bold. Zero flow is the shut-off point, a ceiling rather than a working point; — marks flows past the end of that curve.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBest operating range:\u003c\/strong\u003e the published curve shades the most efficient operating range; the catalog prints no figures for it. The curve is in the image gallery.\u003c\/p\u003e\n\u003cdiv style=\"display:flex;flex-wrap:wrap;gap:10px;margin:22px 0 4px\"\u003e\n\u003ca href=\"\/pages\/submersible-well-pump-sizing-calculator\" style=\"flex:1 1 200px;text-align:center;display:block;background:#B3122A;color:#ffffff;font-family:Arial Black,Arial,sans-serif;font-size:12px;text-transform:uppercase;letter-spacing:1.2px;padding:11px 18px;text-decoration:none\"\u003eSubmersible Calculator\u003c\/a\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eBefore You Buy — The Limits That Decide the Fit\u003c\/div\u003e\n\u003cdiv class=\"gs-lead\"\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply\u003c\/td\u003e\n\u003ctd\u003e230V single-phase for every build, from a circuit breaker sized per the table below\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure transducer\u003c\/td\u003e\n\u003ctd\u003eMust be installed upright and vertical (manufacturer note)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrive location\u003c\/td\u003e\n\u003ctd\u003eNEMA 3R enclosure, outdoors or indoors; rated to 122°F (104°F for SD3-5HP2); derate above 5500 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor cooling\u003c\/td\u003e\n\u003ctd\u003e1.0 ft\/sec of water flow past the motor at 95°F; motor rated to 95°F water\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWell size\u003c\/td\u003e\n\u003ctd\u003e4 in casing and larger\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePairing\u003c\/td\u003e\n\u003ctd\u003eOne pump and one drive per well\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"margin:14px 0 4px\"\u003e\u003cstrong\u003eBreaker sizing by motor HP (manufacturer recommendation)\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSupply\u003c\/th\u003e\n\u003cth\u003eMotor HP\u003c\/th\u003e\n\u003cth\u003eInput Current\u003c\/th\u003e\n\u003cth\u003eFuse \/ Breaker\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e230V\u003c\/td\u003e\n\u003ctd\u003e1\/2\u003c\/td\u003e\n\u003ctd\u003e6 A\u003c\/td\u003e\n\u003ctd\u003e10 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e230V\u003c\/td\u003e\n\u003ctd\u003e3\/4\u003c\/td\u003e\n\u003ctd\u003e9 A\u003c\/td\u003e\n\u003ctd\u003e15 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e230V\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003ctd\u003e14 A\u003c\/td\u003e\n\u003ctd\u003e20 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e230V\u003c\/td\u003e\n\u003ctd\u003e1 1\/2\u003c\/td\u003e\n\u003ctd\u003e18 A\u003c\/td\u003e\n\u003ctd\u003e25 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e230V\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e28 A\u003c\/td\u003e\n\u003ctd\u003e35 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e230V\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e20 A\u003c\/td\u003e\n\u003ctd\u003e25 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e230V\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003ctd\u003e30 A\u003c\/td\u003e\n\u003ctd\u003e40 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e230V\u003c\/td\u003e\n\u003ctd\u003e5\u003c\/td\u003e\n\u003ctd\u003e42 A\u003c\/td\u003e\n\u003ctd\u003e55 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"font-size:12.5px;color:#9B9EA3;margin-top:8px;line-height:1.55\"\u003eSource: Pumps by Baker catalog (Sept 2025, rev 3\/26), p. 131.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eMaterials of Construction (Pump)\u003c\/div\u003e\n\u003cdiv class=\"gs-lead\"\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eDischarge head\u003c\/td\u003e\n\u003ctd\u003eStainless steel 304, 1 1\/4 in NPT discharge\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor adapter\u003c\/td\u003e\n\u003ctd\u003eStainless steel 304, NEMA standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCheck valve\u003c\/td\u003e\n\u003ctd\u003eStainless steel 304\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExternal shell\u003c\/td\u003e\n\u003ctd\u003eStainless steel 304, polished\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eImpellers\u003c\/td\u003e\n\u003ctd\u003eNoryl\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiffusers\u003c\/td\u003e\n\u003ctd\u003ePolycarbonate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBearing\u003c\/td\u003e\n\u003ctd\u003ePolyacetal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShaft coupling\u003c\/td\u003e\n\u003ctd\u003eStainless steel 304, NEMA standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStrainer\u003c\/td\u003e\n\u003ctd\u003eThermoplastic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShaft\u003c\/td\u003e\n\u003ctd\u003eStainless steel 304\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable guard\u003c\/td\u003e\n\u003ctd\u003eStainless steel 304\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"font-size:12.5px;color:#9B9EA3;margin-top:8px;line-height:1.55\"\u003eSource: Pumps by Baker catalog (Sept 2025, rev 3\/26), pp. 65-66.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eService Parts\u003c\/div\u003e\n\u003cdiv class=\"gs-lead\"\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003ePart\u003c\/th\u003e\n\u003cth\u003ePart No.\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutoDRIVE pressure transducer with 10 ft wire\u003c\/td\u003e\n\u003ctd\u003e6619-028\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutoDRIVE pressure switch with wire\u003c\/td\u003e\n\u003ctd\u003e6619-029\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutoDRIVE keypad\u003c\/td\u003e\n\u003ctd\u003e6619-030\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"font-size:12.5px;color:#9B9EA3;margin-top:8px;line-height:1.55\"\u003eSource: Pumps by Baker catalog (Sept 2025, rev 3\/26), pp. 142-143.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"gs-contact\"\u003eFor engineering-led sizing and selection support or a factory submittal, email \u003ca href=\"mailto:sales@watermainsupply.com\"\u003esales@watermainsupply.com\u003c\/a\u003e or call \u003ca href=\"tel:18885104036\"\u003e1-888.510.4036\u003c\/a\u003e.\u003cbr\u003e© Watermain Supply — A division of E4 Industrial LLC\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch5\u003eData Sheet\u003c\/h5\u003e\n\u003cdiv class=\"gs\"\u003e\n\u003cdiv class=\"gs-dl\"\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0264\/1913\/4527\/files\/AutoPac_Guide.pdf?v=1772502299\" target=\"_blank\" rel=\"noopener\"\u003ePumps by Baker AutoPac Guide\u003c\/a\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch5\u003eVideos\u003c\/h5\u003e\n\u003cdiv class=\"gs\"\u003e\u003cdiv class=\"gs-sec\" style=\"margin-top:6px\"\u003e\n\u003cp style=\"font-size:13px;color:#9B9EA3\"\u003eProduct videos are being added to this listing. For a walkthrough in the meantime, email sales@watermainsupply.com.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003c!-- \/TABS --\u003e","brand":"A.Y. McDonald","offers":[{"title":"1\/2 HP - 4 in Motor \/ 230V 1Ph 2-Wire \/ Switch - 24050P2-APS - 91 ft at 20 GPM","offer_id":46602933174447,"sku":"6630-705","price":1955.61,"currency_code":"USD","in_stock":true},{"title":"1\/2 HP - 4 in Motor \/ 230V 1Ph 2-Wire \/ Transducer - 24050P2-APT - 91 ft at 20 GPM","offer_id":46602933305519,"sku":"6630-700","price":2134.0,"currency_code":"USD","in_stock":true},{"title":"1\/2 HP - 4 in Motor \/ 230V 1Ph 3-Wire \/ Switch - 24050P3-APS - 91 ft at 20 GPM","offer_id":46602933436591,"sku":"6630-749","price":1869.23,"currency_code":"USD","in_stock":true},{"title":"1\/2 HP - 4 in Motor \/ 230V 1Ph 3-Wire \/ Transducer - 24050P3-APT - 91 ft at 20 GPM","offer_id":46602933600431,"sku":"6630-744","price":2048.14,"currency_code":"USD","in_stock":true},{"title":"3\/4 HP - 4 in Motor \/ 230V 1Ph 2-Wire \/ Switch - 24075P2-APS - 120 ft at 20 GPM","offer_id":46602933207215,"sku":"6630-715","price":2140.14,"currency_code":"USD","in_stock":true},{"title":"3\/4 HP - 4 in Motor \/ 230V 1Ph 2-Wire \/ Transducer - 24075P2-APT - 120 ft at 20 GPM","offer_id":46602933338287,"sku":"6630-710","price":2318.0,"currency_code":"USD","in_stock":true},{"title":"3\/4 HP - 4 in Motor \/ 230V 1Ph 3-Wire \/ Switch - 24075P3-APS - 120 ft at 20 GPM","offer_id":46602933469359,"sku":"6630-759","price":2024.62,"currency_code":"USD","in_stock":true},{"title":"3\/4 HP - 4 in Motor \/ 230V 1Ph 3-Wire \/ Transducer - 24075P3-APT - 120 ft at 20 GPM","offer_id":46602933633199,"sku":"6630-754","price":2203.01,"currency_code":"USD","in_stock":true},{"title":"1 HP - 4 in Motor \/ 230V 1Ph 2-Wire \/ Switch - 24100P2-APS - 160 ft at 20 GPM","offer_id":46602933239983,"sku":"6630-726","price":2207.61,"currency_code":"USD","in_stock":true},{"title":"1 HP - 4 in Motor \/ 230V 1Ph 2-Wire \/ Transducer - 24100P2-APT - 160 ft at 20 GPM","offer_id":46602933371055,"sku":"6630-720","price":2385.98,"currency_code":"USD","in_stock":true},{"title":"1 HP - 4 in Motor \/ 230V 1Ph 3-Wire \/ Switch - 24100P3-APS - 160 ft at 20 GPM","offer_id":46602933502127,"sku":"6630-770","price":2066.53,"currency_code":"USD","in_stock":true},{"title":"1 HP - 4 in Motor \/ 230V 1Ph 3-Wire \/ Transducer - 24100P3-APT - 160 ft at 20 GPM","offer_id":46602933665967,"sku":"6630-764","price":2245.43,"currency_code":"USD","in_stock":true},{"title":"1 1\/2 HP - 4 in Motor \/ 230V 1Ph 2-Wire \/ Switch - 24150P2-APS - 228 ft at 20 GPM","offer_id":46602933272751,"sku":"6630-738","price":2377.34,"currency_code":"USD","in_stock":true},{"title":"1 1\/2 HP - 4 in Motor \/ 230V 1Ph 2-Wire \/ Transducer - 24150P2-APT - 228 ft at 20 GPM","offer_id":46602933403823,"sku":"6630-732","price":2555.71,"currency_code":"USD","in_stock":true},{"title":"1 1\/2 HP - 4 in Motor \/ 230V 1Ph 3-Wire \/ Switch - 24150P3-APS - 228 ft at 20 GPM","offer_id":46602933534895,"sku":"6630-782","price":2193.34,"currency_code":"USD","in_stock":true},{"title":"1 1\/2 HP - 4 in Motor \/ 230V 1Ph 3-Wire \/ Transducer - 24150P3-APT - 228 ft at 20 GPM","offer_id":46602933698735,"sku":"6630-776","price":2371.2,"currency_code":"USD","in_stock":true},{"title":"1 1\/2 HP - 4 in Motor \/ 230V 3Ph \/ Transducer - 24150P3Z-APT - 228 ft at 20 GPM","offer_id":46602933764271,"sku":"6630-859","price":2593.5,"currency_code":"USD","in_stock":true},{"title":"2 HP - 4 in Motor \/ 230V 1Ph 3-Wire \/ Switch - 24200P3-APS - 290 ft at 20 GPM","offer_id":46602933567663,"sku":"6630-792","price":2515.85,"currency_code":"USD","in_stock":true},{"title":"2 HP - 4 in Motor \/ 230V 1Ph 3-Wire \/ Transducer - 24200P3-APT - 290 ft at 20 GPM","offer_id":46602933731503,"sku":"6630-787","price":2694.75,"currency_code":"USD","in_stock":true},{"title":"2 HP - 4 in Motor \/ 230V 3Ph \/ Transducer - 24200P3Z-APT - 290 ft at 20 GPM","offer_id":46602933797039,"sku":"6630-797","price":2912.99,"currency_code":"USD","in_stock":true},{"title":"3 HP - 4 in Motor \/ 230V 3Ph \/ Transducer - 24300P3Z-APT - 393 ft at 20 GPM","offer_id":46602933829807,"sku":"6630-801","price":3592.8,"currency_code":"USD","in_stock":true},{"title":"5 HP - 4 in Motor \/ 230V 3Ph \/ Transducer - 24500P3Z-APT - 619 ft at 20 GPM","offer_id":46602933862575,"sku":"6630-805","price":5051.65,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0264\/1913\/4527\/files\/AutoPac_e845f0d5-0fe5-4980-a8ab-8ecfc3fadd56.png?v=1772502613"},{"product_id":"baker-autopac-m-25-gpm-24000-series","title":"A.Y. McDonald AutoPAC M - 25 GPM 24000 Constant Pressure Pump","description":"\u003c!-- TABS --\u003e\n\u003ch5\u003eDescription\u003c\/h5\u003e\n\u003cdiv class=\"gs\"\u003e\n\u003cdiv class=\"gs-head\"\u003e\n\u003cdiv class=\"gs-eyebrow\"\u003eA.Y. McDonald · Constant Pressure Pump System\u003c\/div\u003e\n\u003cdiv class=\"gs-title\"\u003eAutoPAC M - 25 GPM, 24000 Series\u003c\/div\u003e\n\u003cdiv class=\"gs-sub\"\u003eBaker stainless steel 4 in submersible pump, motor and AutoDRIVE constant pressure drive, 1 to 5 HP, 14 builds.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"gs-badges\"\u003e\n\u003cdiv class=\"gs-badge\" style=\"background:#B3122A;color:#FFFFFF;border-color:#B3122A\"\u003e134-502 ft at 25 GPM\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003e1-5 HP\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003e230V Single-Phase Supply\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003eAutoDRIVE Constant Pressure VFD\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003ePressure Switch or Transducer Control\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003e762 ft Max Head (Shut-off)\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003e1 1\/4 in NPT Discharge\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003eNEMA 3R Drive Enclosure\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003eDrinking Water ANSI\/NSF 61\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003e47-86 lb Weight\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background:#FFFFFF;border:1px solid #C7CBD1;border-top:3px solid #B3122A;padding:12px 16px 12px;margin:16px 0 4px;font-size:13.5px;line-height:1.55;color:#4A4A4F\"\u003e\n\u003cdiv style=\"font-family:Arial Black,Arial,sans-serif;font-size:11px;letter-spacing:1.2px;text-transform:uppercase;color:#B3122A;margin-bottom:8px\"\u003eWhat Ships and What It Needs to Run\u003c\/div\u003e\n\u003cp style=\"margin:0 0 6px\"\u003e\u003cstrong style=\"color:#B3122A\"\u003eIncluded:\u003c\/strong\u003e the pump end and Baker 4 in motor, assembled, with the AutoDRIVE constant pressure drive matched to the motor, and the pressure switch (APS models) or pressure transducer with 10 ft wire (APT models). The drive model for each build is in the Models table.\u003c\/p\u003e\n\u003cp style=\"margin:0 0 6px\"\u003e\u003cstrong style=\"color:#B3122A\"\u003ePower:\u003c\/strong\u003e 230V single-phase supply from a circuit breaker for every build; the three-phase builds take single-phase power and the drive makes three-phase for the motor. Breaker sizes are under Before You Buy.\u003c\/p\u003e\n\u003cp style=\"margin:0\"\u003e\u003cstrong style=\"color:#B3122A\"\u003eSized at install:\u003c\/strong\u003e drop cable, splice kit and the pressure relief valve shown in the manufacturer’s installation diagram.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eOverview\u003c\/div\u003e\n\u003cdiv class=\"gs-lead\"\u003e\n\u003cp\u003eThe AutoPAC is Baker’s constant pressure well package: a 24000 Series 4 in submersible pump, a Baker motor of the same horsepower, and the AutoDRIVE variable frequency drive. The drive holds a set pressure by changing the pump speed, which allows a smaller pressure tank and a quick, simple installation; setup takes 5 steps or less on the drive’s backlit display.\u003c\/p\u003e\n\u003cp\u003eThis listing is the \u003cstrong\u003eM - 25 GPM\u003c\/strong\u003e class: 1 to 5 HP, with pressure switch and transducer control. The AutoDRIVE is American made and housed in a NEMA 3R steel enclosure rated for outdoor use.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background:#E1E3E6;border-left:3px solid #B8BDC4;padding:8px 14px;font-size:11.5px;color:#4A4A4F;margin-top:14px;line-height:1.5\"\u003eGenuine A.Y. McDonald equipment, factory-new in original packaging — sold and supported by Watermain Supply, an independent industrial supplier. Watermain Supply is an Authorized Stocking A.Y. McDonald and Baker Water Systems Distributor.\u003c\/div\u003e\n\u003cdiv style=\"background:#fff;border-left:5px solid #B3122A;padding:15px 18px;margin-top:12px\"\u003e\n\u003cdiv style=\"font-family:Arial Black,Arial,sans-serif;font-size:15px;color:#B3122A;text-transform:uppercase;letter-spacing:1px;margin-bottom:6px\"\u003eA.Y. McDonald Warranty\u003c\/div\u003e\n\u003cp style=\"margin:0;font-size:13.5px;color:#4A4A4F;line-height:1.55\"\u003ePump and motor: covered for \u003cstrong\u003e5 years from the date of manufacture in potable water applications\u003c\/strong\u003e, and 3 years from the date of manufacture in other applications, under A.Y. McDonald’s published terms for Baker submersible motors and assembled submersible pumps. The AutoDRIVE and pressure control fall under A.Y. McDonald’s standard limited warranty: 2 years from the date of manufacture or 1 year from installation, whichever comes first.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eRoom to Grow\u003c\/div\u003e\n\u003cdiv class=\"gs-lead\"\u003e\n\u003cp\u003eOne pump and one drive per well. Need more head later? Step up in horsepower within the M - 25 GPM class; the drive model changes with the motor (see the Models table). Need more flow? Move to a higher flow class of the AutoPAC 24000 Series; every class uses the same 1 1\/4 in NPT discharge.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eModels \u0026amp; Ratings (60 Hz)\u003c\/div\u003e\n\u003cdiv class=\"gs-lead\"\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003cth\u003ePart No.\u003c\/th\u003e\n\u003cth\u003eHP\u003c\/th\u003e\n\u003cth\u003eMotor\u003c\/th\u003e\n\u003cth\u003eControl\u003c\/th\u003e\n\u003cth\u003eAutoDRIVE\u003c\/th\u003e\n\u003cth\u003eHead at 25 GPM\u003c\/th\u003e\n\u003cth\u003eShut-off Head\u003c\/th\u003e\n\u003cth\u003eWeight\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e24100M2-APS\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6630-727\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003ctd\u003e230V 1Ph 2-Wire\u003c\/td\u003e\n\u003ctd\u003ePressure Switch\u003c\/td\u003e\n\u003ctd\u003eSD1-2HP2PS\u003c\/td\u003e\n\u003ctd\u003e134 ft\u003c\/td\u003e\n\u003ctd\u003e205 ft\u003c\/td\u003e\n\u003ctd\u003e49 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e24100M2-APT\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6630-721\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003ctd\u003e230V 1Ph 2-Wire\u003c\/td\u003e\n\u003ctd\u003eTransducer\u003c\/td\u003e\n\u003ctd\u003eSD1-2HP2\u003c\/td\u003e\n\u003ctd\u003e134 ft\u003c\/td\u003e\n\u003ctd\u003e205 ft\u003c\/td\u003e\n\u003ctd\u003e49 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e24100M3-APS\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6630-771\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003ctd\u003e230V 1Ph 3-Wire\u003c\/td\u003e\n\u003ctd\u003ePressure Switch\u003c\/td\u003e\n\u003ctd\u003eSD1-2HP2PS\u003c\/td\u003e\n\u003ctd\u003e134 ft\u003c\/td\u003e\n\u003ctd\u003e205 ft\u003c\/td\u003e\n\u003ctd\u003e48 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e24100M3-APT\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6630-765\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003ctd\u003e230V 1Ph 3-Wire\u003c\/td\u003e\n\u003ctd\u003eTransducer\u003c\/td\u003e\n\u003ctd\u003eSD1-2HP2\u003c\/td\u003e\n\u003ctd\u003e134 ft\u003c\/td\u003e\n\u003ctd\u003e205 ft\u003c\/td\u003e\n\u003ctd\u003e49 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e24150M2-APS\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6630-739\u003c\/td\u003e\n\u003ctd\u003e1 1\/2\u003c\/td\u003e\n\u003ctd\u003e230V 1Ph 2-Wire\u003c\/td\u003e\n\u003ctd\u003ePressure Switch\u003c\/td\u003e\n\u003ctd\u003eSD1-2HP2PS\u003c\/td\u003e\n\u003ctd\u003e172 ft\u003c\/td\u003e\n\u003ctd\u003e264 ft\u003c\/td\u003e\n\u003ctd\u003e55 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e24150M2-APT\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6630-733\u003c\/td\u003e\n\u003ctd\u003e1 1\/2\u003c\/td\u003e\n\u003ctd\u003e230V 1Ph 2-Wire\u003c\/td\u003e\n\u003ctd\u003eTransducer\u003c\/td\u003e\n\u003ctd\u003eSD1-2HP2\u003c\/td\u003e\n\u003ctd\u003e172 ft\u003c\/td\u003e\n\u003ctd\u003e264 ft\u003c\/td\u003e\n\u003ctd\u003e55 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e24150M3-APS\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6630-783\u003c\/td\u003e\n\u003ctd\u003e1 1\/2\u003c\/td\u003e\n\u003ctd\u003e230V 1Ph 3-Wire\u003c\/td\u003e\n\u003ctd\u003ePressure Switch\u003c\/td\u003e\n\u003ctd\u003eSD1-2HP2PS\u003c\/td\u003e\n\u003ctd\u003e172 ft\u003c\/td\u003e\n\u003ctd\u003e264 ft\u003c\/td\u003e\n\u003ctd\u003e54 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e24150M3-APT\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6630-777\u003c\/td\u003e\n\u003ctd\u003e1 1\/2\u003c\/td\u003e\n\u003ctd\u003e230V 1Ph 3-Wire\u003c\/td\u003e\n\u003ctd\u003eTransducer\u003c\/td\u003e\n\u003ctd\u003eSD1-2HP2\u003c\/td\u003e\n\u003ctd\u003e172 ft\u003c\/td\u003e\n\u003ctd\u003e264 ft\u003c\/td\u003e\n\u003ctd\u003e54 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e24150M3Z-APT\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6630-860\u003c\/td\u003e\n\u003ctd\u003e1 1\/2\u003c\/td\u003e\n\u003ctd\u003e230V 3Ph\u003c\/td\u003e\n\u003ctd\u003eTransducer\u003c\/td\u003e\n\u003ctd\u003eSD3-2HP2\u003c\/td\u003e\n\u003ctd\u003e172 ft\u003c\/td\u003e\n\u003ctd\u003e264 ft\u003c\/td\u003e\n\u003ctd\u003e47 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e24200M3-APS\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6630-793\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e230V 1Ph 3-Wire\u003c\/td\u003e\n\u003ctd\u003ePressure Switch\u003c\/td\u003e\n\u003ctd\u003eSD1-2HP2PS\u003c\/td\u003e\n\u003ctd\u003e213 ft\u003c\/td\u003e\n\u003ctd\u003e324 ft\u003c\/td\u003e\n\u003ctd\u003e55 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e24200M3-APT\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6630-788\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e230V 1Ph 3-Wire\u003c\/td\u003e\n\u003ctd\u003eTransducer\u003c\/td\u003e\n\u003ctd\u003eSD1-2HP2\u003c\/td\u003e\n\u003ctd\u003e213 ft\u003c\/td\u003e\n\u003ctd\u003e324 ft\u003c\/td\u003e\n\u003ctd\u003e55 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e24200M3Z-APT\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6630-798\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e230V 3Ph\u003c\/td\u003e\n\u003ctd\u003eTransducer\u003c\/td\u003e\n\u003ctd\u003eSD3-2HP2\u003c\/td\u003e\n\u003ctd\u003e213 ft\u003c\/td\u003e\n\u003ctd\u003e324 ft\u003c\/td\u003e\n\u003ctd\u003e53 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e24300M3Z-APT\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6630-802\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003ctd\u003e230V 3Ph\u003c\/td\u003e\n\u003ctd\u003eTransducer\u003c\/td\u003e\n\u003ctd\u003eSD3-3HP2\u003c\/td\u003e\n\u003ctd\u003e290 ft\u003c\/td\u003e\n\u003ctd\u003e438 ft\u003c\/td\u003e\n\u003ctd\u003e66 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e24500M3Z-APT\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6630-806\u003c\/td\u003e\n\u003ctd\u003e5\u003c\/td\u003e\n\u003ctd\u003e230V 3Ph\u003c\/td\u003e\n\u003ctd\u003eTransducer\u003c\/td\u003e\n\u003ctd\u003eSD3-5HP2\u003c\/td\u003e\n\u003ctd\u003e502 ft\u003c\/td\u003e\n\u003ctd\u003e762 ft\u003c\/td\u003e\n\u003ctd\u003e86 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"font-size:12.5px;color:#9B9EA3;margin-top:8px;line-height:1.55\"\u003eHead at 25 GPM is read from the published AutoPAC curve (Pumps by Baker catalog (Sept 2025, rev 3\/26), p. 156), digitized and rounded down. Shut-off head as printed. Drive per the compatibility table on p. 141 (1 1\/2 HP three-phase builds use the SD3-2HP2). Sources: Pumps by Baker catalog (Sept 2025, rev 3\/26), pp. 141-143 and 156; Baker Pumps and Accessories price list, effective 7\/1\/2026.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eShared Specifications\u003c\/div\u003e\n\u003cdiv class=\"gs-lead\"\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eIncluded\u003c\/td\u003e\n\u003ctd\u003ePump end, Baker 4 in motor, AutoDRIVE drive, and pressure switch or transducer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDischarge\u003c\/td\u003e\n\u003ctd\u003e1 1\/4 in NPT (female)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCheck valve\u003c\/td\u003e\n\u003ctd\u003eBuilt in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply\u003c\/td\u003e\n\u003ctd\u003e230V single-phase, 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor\u003c\/td\u003e\n\u003ctd\u003eBaker 4 in submersible motor, matched to the pump end horsepower\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePump diameter\u003c\/td\u003e\n\u003ctd\u003e3 3\/4 in with cable guard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrive enclosure\u003c\/td\u003e\n\u003ctd\u003eNEMA Type 3R steel, 12.25 x 9.25 x 4.68 in, 13 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrive operating temperature\u003c\/td\u003e\n\u003ctd\u003e-4 to 122°F; SD3-5HP2 rated to 104°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrive efficiency\u003c\/td\u003e\n\u003ctd\u003e95%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertification (pump)\u003c\/td\u003e\n\u003ctd\u003eDrinking Water ANSI\/NSF 61\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApp connection\u003c\/td\u003e\n\u003ctd\u003eNone; set up on the drive display\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"font-size:12.5px;color:#9B9EA3;margin-top:8px;line-height:1.55\"\u003eSource: Pumps by Baker catalog (Sept 2025, rev 3\/26), pp. 131-133 and 141-143.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003ePerformance — Will It Do What You Need?\u003c\/div\u003e\n\u003cdiv class=\"gs-lead\"\u003e\n\u003cp\u003e\u003cstrong\u003eTotal head\u003c\/strong\u003e is everything the pump lifts against: the vertical lift from the pumping water level to the discharge, the pressure you set on the drive (2.31 ft for every PSI), and friction in the drop pipe. The drive slows the pump when demand falls, so the curve below is the most the pump delivers at full speed.\u003c\/p\u003e\n\u003cp style=\"margin-bottom:4px\"\u003e\u003cstrong\u003eTotal head in feet, by flow in GPM, at full speed\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eHP (stages)\u003c\/th\u003e\n\u003cth\u003e0\u003c\/th\u003e\n\u003cth\u003e5\u003c\/th\u003e\n\u003cth\u003e10\u003c\/th\u003e\n\u003cth\u003e15\u003c\/th\u003e\n\u003cth\u003e20\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003e25\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e30\u003c\/th\u003e\n\u003cth\u003e35\u003c\/th\u003e\n\u003cth\u003e38.5\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e1 HP (7)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e206\u003c\/td\u003e\n\u003ctd\u003e205\u003c\/td\u003e\n\u003ctd\u003e197\u003c\/td\u003e\n\u003ctd\u003e182\u003c\/td\u003e\n\u003ctd\u003e161\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e134\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100\u003c\/td\u003e\n\u003ctd\u003e59\u003c\/td\u003e\n\u003ctd\u003e26\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e1 1\/2 HP (9)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e266\u003c\/td\u003e\n\u003ctd\u003e259\u003c\/td\u003e\n\u003ctd\u003e251\u003c\/td\u003e\n\u003ctd\u003e235\u003c\/td\u003e\n\u003ctd\u003e209\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e172\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e127\u003c\/td\u003e\n\u003ctd\u003e75\u003c\/td\u003e\n\u003ctd\u003e40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e2 HP (11)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e325\u003c\/td\u003e\n\u003ctd\u003e314\u003c\/td\u003e\n\u003ctd\u003e301\u003c\/td\u003e\n\u003ctd\u003e283\u003c\/td\u003e\n\u003ctd\u003e254\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e213\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e154\u003c\/td\u003e\n\u003ctd\u003e73\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e3 HP (15)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e440\u003c\/td\u003e\n\u003ctd\u003e432\u003c\/td\u003e\n\u003ctd\u003e416\u003c\/td\u003e\n\u003ctd\u003e390\u003c\/td\u003e\n\u003ctd\u003e349\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e290\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e209\u003c\/td\u003e\n\u003ctd\u003e103\u003c\/td\u003e\n\u003ctd\u003e13\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e5 HP (26)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e764\u003c\/td\u003e\n\u003ctd\u003e744\u003c\/td\u003e\n\u003ctd\u003e719\u003c\/td\u003e\n\u003ctd\u003e677\u003c\/td\u003e\n\u003ctd\u003e607\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e502\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e359\u003c\/td\u003e\n\u003ctd\u003e177\u003c\/td\u003e\n\u003ctd\u003e28\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"font-size:12.5px;color:#9B9EA3;margin-top:6px;line-height:1.55\"\u003eDigitized from the published AutoPAC curve in the Pumps by Baker catalog (Sept 2025, rev 3\/26), p. 156, and rounded down. Rated flow (25 GPM) in bold. Zero flow is the shut-off point, a ceiling rather than a working point; — marks flows past the end of that curve.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBest operating range:\u003c\/strong\u003e the published curve shades the most efficient operating range; the catalog prints no figures for it. The curve is in the image gallery.\u003c\/p\u003e\n\u003cdiv style=\"display:flex;flex-wrap:wrap;gap:10px;margin:22px 0 4px\"\u003e\n\u003ca href=\"\/pages\/submersible-well-pump-sizing-calculator\" style=\"flex:1 1 200px;text-align:center;display:block;background:#B3122A;color:#ffffff;font-family:Arial Black,Arial,sans-serif;font-size:12px;text-transform:uppercase;letter-spacing:1.2px;padding:11px 18px;text-decoration:none\"\u003eSubmersible Calculator\u003c\/a\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eBefore You Buy — The Limits That Decide the Fit\u003c\/div\u003e\n\u003cdiv class=\"gs-lead\"\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply\u003c\/td\u003e\n\u003ctd\u003e230V single-phase for every build, from a circuit breaker sized per the table below\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure transducer\u003c\/td\u003e\n\u003ctd\u003eMust be installed upright and vertical (manufacturer note)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrive location\u003c\/td\u003e\n\u003ctd\u003eNEMA 3R enclosure, outdoors or indoors; rated to 122°F (104°F for SD3-5HP2); derate above 5500 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor cooling\u003c\/td\u003e\n\u003ctd\u003e1.0 ft\/sec of water flow past the motor at 95°F; motor rated to 95°F water\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWell size\u003c\/td\u003e\n\u003ctd\u003e4 in casing and larger\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePairing\u003c\/td\u003e\n\u003ctd\u003eOne pump and one drive per well\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"margin:14px 0 4px\"\u003e\u003cstrong\u003eBreaker sizing by motor HP (manufacturer recommendation)\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSupply\u003c\/th\u003e\n\u003cth\u003eMotor HP\u003c\/th\u003e\n\u003cth\u003eInput Current\u003c\/th\u003e\n\u003cth\u003eFuse \/ Breaker\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e230V\u003c\/td\u003e\n\u003ctd\u003e1\/2\u003c\/td\u003e\n\u003ctd\u003e6 A\u003c\/td\u003e\n\u003ctd\u003e10 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e230V\u003c\/td\u003e\n\u003ctd\u003e3\/4\u003c\/td\u003e\n\u003ctd\u003e9 A\u003c\/td\u003e\n\u003ctd\u003e15 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e230V\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003ctd\u003e14 A\u003c\/td\u003e\n\u003ctd\u003e20 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e230V\u003c\/td\u003e\n\u003ctd\u003e1 1\/2\u003c\/td\u003e\n\u003ctd\u003e18 A\u003c\/td\u003e\n\u003ctd\u003e25 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e230V\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e28 A\u003c\/td\u003e\n\u003ctd\u003e35 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e230V\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e20 A\u003c\/td\u003e\n\u003ctd\u003e25 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e230V\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003ctd\u003e30 A\u003c\/td\u003e\n\u003ctd\u003e40 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e230V\u003c\/td\u003e\n\u003ctd\u003e5\u003c\/td\u003e\n\u003ctd\u003e42 A\u003c\/td\u003e\n\u003ctd\u003e55 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"font-size:12.5px;color:#9B9EA3;margin-top:8px;line-height:1.55\"\u003eSource: Pumps by Baker catalog (Sept 2025, rev 3\/26), p. 131.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eMaterials of Construction (Pump)\u003c\/div\u003e\n\u003cdiv class=\"gs-lead\"\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eDischarge head\u003c\/td\u003e\n\u003ctd\u003eStainless steel 304, 1 1\/4 in NPT discharge\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor adapter\u003c\/td\u003e\n\u003ctd\u003eStainless steel 304, NEMA standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCheck valve\u003c\/td\u003e\n\u003ctd\u003eStainless steel 304\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExternal shell\u003c\/td\u003e\n\u003ctd\u003eStainless steel 304, polished\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eImpellers\u003c\/td\u003e\n\u003ctd\u003eNoryl\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiffusers\u003c\/td\u003e\n\u003ctd\u003ePolycarbonate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBearing\u003c\/td\u003e\n\u003ctd\u003ePolyacetal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShaft coupling\u003c\/td\u003e\n\u003ctd\u003eStainless steel 304, NEMA standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStrainer\u003c\/td\u003e\n\u003ctd\u003eThermoplastic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShaft\u003c\/td\u003e\n\u003ctd\u003eStainless steel 304\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable guard\u003c\/td\u003e\n\u003ctd\u003eStainless steel 304\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"font-size:12.5px;color:#9B9EA3;margin-top:8px;line-height:1.55\"\u003eSource: Pumps by Baker catalog (Sept 2025, rev 3\/26), pp. 65-66.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eService Parts\u003c\/div\u003e\n\u003cdiv class=\"gs-lead\"\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003ePart\u003c\/th\u003e\n\u003cth\u003ePart No.\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutoDRIVE pressure transducer with 10 ft wire\u003c\/td\u003e\n\u003ctd\u003e6619-028\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutoDRIVE pressure switch with wire\u003c\/td\u003e\n\u003ctd\u003e6619-029\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutoDRIVE keypad\u003c\/td\u003e\n\u003ctd\u003e6619-030\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"font-size:12.5px;color:#9B9EA3;margin-top:8px;line-height:1.55\"\u003eSource: Pumps by Baker catalog (Sept 2025, rev 3\/26), pp. 142-143.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"gs-contact\"\u003eFor engineering-led sizing and selection support or a factory submittal, email \u003ca href=\"mailto:sales@watermainsupply.com\"\u003esales@watermainsupply.com\u003c\/a\u003e or call \u003ca href=\"tel:18885104036\"\u003e1-888.510.4036\u003c\/a\u003e.\u003cbr\u003e© Watermain Supply — A division of E4 Industrial LLC\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch5\u003eData Sheet\u003c\/h5\u003e\n\u003cdiv class=\"gs\"\u003e\n\u003cdiv class=\"gs-dl\"\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0264\/1913\/4527\/files\/AutoPac_Guide.pdf?v=1772502299\" target=\"_blank\" rel=\"noopener\"\u003ePumps by Baker AutoPac Guide\u003c\/a\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch5\u003eVideos\u003c\/h5\u003e\n\u003cdiv class=\"gs\"\u003e\u003cdiv class=\"gs-sec\" style=\"margin-top:6px\"\u003e\n\u003cp style=\"font-size:13px;color:#9B9EA3\"\u003eProduct videos are being added to this listing. For a walkthrough in the meantime, email sales@watermainsupply.com.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003c!-- \/TABS --\u003e","brand":"A.Y. McDonald","offers":[{"title":"1 HP - 4 in Motor \/ 230V 1Ph 2-Wire \/ Switch - 24100M2-APS - 134 ft at 25 GPM","offer_id":46602933895343,"sku":"6630-727","price":2136.05,"currency_code":"USD","in_stock":true},{"title":"1 HP - 4 in Motor \/ 230V 1Ph 2-Wire \/ Transducer - 24100M2-APT - 134 ft at 25 GPM","offer_id":46602933960879,"sku":"6630-721","price":2314.93,"currency_code":"USD","in_stock":true},{"title":"1 HP - 4 in Motor \/ 230V 1Ph 3-Wire \/ Switch - 24100M3-APS - 134 ft at 25 GPM","offer_id":46602934026415,"sku":"6630-771","price":1995.49,"currency_code":"USD","in_stock":true},{"title":"1 HP - 4 in Motor \/ 230V 1Ph 3-Wire \/ Transducer - 24100M3-APT - 134 ft at 25 GPM","offer_id":46602934124719,"sku":"6630-765","price":2173.86,"currency_code":"USD","in_stock":true},{"title":"1 1\/2 HP - 4 in Motor \/ 230V 1Ph 2-Wire \/ Switch - 24150M2-APS - 172 ft at 25 GPM","offer_id":46602933928111,"sku":"6630-739","price":2422.83,"currency_code":"USD","in_stock":true},{"title":"1 1\/2 HP - 4 in Motor \/ 230V 1Ph 2-Wire \/ Transducer - 24150M2-APT - 172 ft at 25 GPM","offer_id":46602933993647,"sku":"6630-733","price":2601.22,"currency_code":"USD","in_stock":true},{"title":"1 1\/2 HP - 4 in Motor \/ 230V 1Ph 3-Wire \/ Switch - 24150M3-APS - 172 ft at 25 GPM","offer_id":46602934059183,"sku":"6630-783","price":2239.34,"currency_code":"USD","in_stock":true},{"title":"1 1\/2 HP - 4 in Motor \/ 230V 1Ph 3-Wire \/ Transducer - 24150M3-APT - 172 ft at 25 GPM","offer_id":46602934157487,"sku":"6630-777","price":2418.23,"currency_code":"USD","in_stock":true},{"title":"1 1\/2 HP - 4 in Motor \/ 230V 3Ph \/ Transducer - 24150M3Z-APT - 172 ft at 25 GPM","offer_id":46602934223023,"sku":"6630-860","price":2640.02,"currency_code":"USD","in_stock":true},{"title":"2 HP - 4 in Motor \/ 230V 1Ph 3-Wire \/ Switch - 24200M3-APS - 213 ft at 25 GPM","offer_id":46602934091951,"sku":"6630-793","price":2444.3,"currency_code":"USD","in_stock":true},{"title":"2 HP - 4 in Motor \/ 230V 1Ph 3-Wire \/ Transducer - 24200M3-APT - 213 ft at 25 GPM","offer_id":46602934190255,"sku":"6630-788","price":2622.68,"currency_code":"USD","in_stock":true},{"title":"2 HP - 4 in Motor \/ 230V 3Ph \/ Transducer - 24200M3Z-APT - 213 ft at 25 GPM","offer_id":46602934255791,"sku":"6630-798","price":2839.91,"currency_code":"USD","in_stock":true},{"title":"3 HP - 4 in Motor \/ 230V 3Ph \/ Transducer - 24300M3Z-APT - 290 ft at 25 GPM","offer_id":46602934288559,"sku":"6630-802","price":3539.64,"currency_code":"USD","in_stock":true},{"title":"5 HP - 4 in Motor \/ 230V 3Ph \/ Transducer - 24500M3Z-APT - 502 ft at 25 GPM","offer_id":46602934321327,"sku":"6630-806","price":4957.1,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0264\/1913\/4527\/files\/AutoPac_8ffd9ee7-8741-490f-b44e-6b969cdfb50d.png?v=1772502615"},{"product_id":"baker-autopac-r-35-gpm-24000-series","title":"A.Y. McDonald AutoPAC R - 35 GPM 24000 Constant Pressure Pump","description":"\u003c!-- TABS --\u003e\n\u003ch5\u003eDescription\u003c\/h5\u003e\n\u003cdiv class=\"gs\"\u003e\n\u003cdiv class=\"gs-head\"\u003e\n\u003cdiv class=\"gs-eyebrow\"\u003eA.Y. McDonald · Constant Pressure Pump System\u003c\/div\u003e\n\u003cdiv class=\"gs-title\"\u003eAutoPAC R - 35 GPM, 24000 Series High Flow\u003c\/div\u003e\n\u003cdiv class=\"gs-sub\"\u003eBaker stainless steel 4 in submersible pump, motor and AutoDRIVE constant pressure drive, 1 to 5 HP, 15 builds.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"gs-badges\"\u003e\n\u003cdiv class=\"gs-badge\" style=\"background:#B3122A;color:#FFFFFF;border-color:#B3122A\"\u003e109-434 ft at 35 GPM\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003e1-5 HP\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003e230V Single-Phase Supply\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003eAutoDRIVE Constant Pressure VFD\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003ePressure Switch or Transducer Control\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003e656 ft Max Head (Shut-off)\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003e2 in NPT Discharge\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003eNEMA 3R Drive Enclosure\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003eDrinking Water ANSI\/NSF 61\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003e48-83 lb Weight\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background:#FFFFFF;border:1px solid #C7CBD1;border-top:3px solid #B3122A;padding:12px 16px 12px;margin:16px 0 4px;font-size:13.5px;line-height:1.55;color:#4A4A4F\"\u003e\n\u003cdiv style=\"font-family:Arial Black,Arial,sans-serif;font-size:11px;letter-spacing:1.2px;text-transform:uppercase;color:#B3122A;margin-bottom:8px\"\u003eWhat Ships and What It Needs to Run\u003c\/div\u003e\n\u003cp style=\"margin:0 0 6px\"\u003e\u003cstrong style=\"color:#B3122A\"\u003eIncluded:\u003c\/strong\u003e the pump end and Baker 4 in motor, assembled, with the AutoDRIVE constant pressure drive matched to the motor, and the pressure switch (APS models) or pressure transducer with 10 ft wire (APT models). The drive model for each build is in the Models table.\u003c\/p\u003e\n\u003cp style=\"margin:0 0 6px\"\u003e\u003cstrong style=\"color:#B3122A\"\u003ePower:\u003c\/strong\u003e 230V single-phase supply from a circuit breaker for every build; the three-phase builds take single-phase power and the drive makes three-phase for the motor. Breaker sizes are under Before You Buy.\u003c\/p\u003e\n\u003cp style=\"margin:0\"\u003e\u003cstrong style=\"color:#B3122A\"\u003eSized at install:\u003c\/strong\u003e drop cable, splice kit and the pressure relief valve shown in the manufacturer’s installation diagram.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eOverview\u003c\/div\u003e\n\u003cdiv class=\"gs-lead\"\u003e\n\u003cp\u003eThe AutoPAC is Baker’s constant pressure well package: a 24000 Series High Flow 4 in submersible pump, a Baker motor of the same horsepower, and the AutoDRIVE variable frequency drive. The drive holds a set pressure by changing the pump speed, which allows a smaller pressure tank and a quick, simple installation; setup takes 5 steps or less on the drive’s backlit display.\u003c\/p\u003e\n\u003cp\u003eThis listing is the \u003cstrong\u003eR - 35 GPM\u003c\/strong\u003e class: 1 to 5 HP, with pressure switch and transducer control. The AutoDRIVE is American made and housed in a NEMA 3R steel enclosure rated for outdoor use.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background:#E1E3E6;border-left:3px solid #B8BDC4;padding:8px 14px;font-size:11.5px;color:#4A4A4F;margin-top:14px;line-height:1.5\"\u003eGenuine A.Y. McDonald equipment, factory-new in original packaging — sold and supported by Watermain Supply, an independent industrial supplier. Watermain Supply is an Authorized Stocking A.Y. McDonald and Baker Water Systems Distributor.\u003c\/div\u003e\n\u003cdiv style=\"background:#fff;border-left:5px solid #B3122A;padding:15px 18px;margin-top:12px\"\u003e\n\u003cdiv style=\"font-family:Arial Black,Arial,sans-serif;font-size:15px;color:#B3122A;text-transform:uppercase;letter-spacing:1px;margin-bottom:6px\"\u003eA.Y. McDonald Warranty\u003c\/div\u003e\n\u003cp style=\"margin:0;font-size:13.5px;color:#4A4A4F;line-height:1.55\"\u003ePump and motor: covered for \u003cstrong\u003e3 years from the date of manufacture\u003c\/strong\u003e under A.Y. McDonald’s published terms for Baker submersible motors and assembled submersible pumps with pump ends up to 80 GPM. The AutoDRIVE and pressure control fall under A.Y. McDonald’s standard limited warranty: 2 years from the date of manufacture or 1 year from installation, whichever comes first.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eRoom to Grow\u003c\/div\u003e\n\u003cdiv class=\"gs-lead\"\u003e\n\u003cp\u003eOne pump and one drive per well. Need more head later? Step up in horsepower within the R - 35 GPM class; the drive model changes with the motor (see the Models table). Need more flow? Move to a higher flow class of the AutoPAC 24000 Series; every class uses the same 2 in NPT discharge.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eModels \u0026amp; Ratings (60 Hz)\u003c\/div\u003e\n\u003cdiv class=\"gs-lead\"\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003cth\u003ePart No.\u003c\/th\u003e\n\u003cth\u003eHP\u003c\/th\u003e\n\u003cth\u003eMotor\u003c\/th\u003e\n\u003cth\u003eControl\u003c\/th\u003e\n\u003cth\u003eAutoDRIVE\u003c\/th\u003e\n\u003cth\u003eHead at 35 GPM\u003c\/th\u003e\n\u003cth\u003eShut-off Head\u003c\/th\u003e\n\u003cth\u003eWeight\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e24100R2-APS\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6630-808\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003ctd\u003e230V 1Ph 2-Wire\u003c\/td\u003e\n\u003ctd\u003ePressure Switch\u003c\/td\u003e\n\u003ctd\u003eSD1-2HP2PS\u003c\/td\u003e\n\u003ctd\u003e109 ft\u003c\/td\u003e\n\u003ctd\u003e170 ft\u003c\/td\u003e\n\u003ctd\u003e50 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e24100R2-APT\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6630-807\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003ctd\u003e230V 1Ph 2-Wire\u003c\/td\u003e\n\u003ctd\u003eTransducer\u003c\/td\u003e\n\u003ctd\u003eSD1-2HP2\u003c\/td\u003e\n\u003ctd\u003e109 ft\u003c\/td\u003e\n\u003ctd\u003e170 ft\u003c\/td\u003e\n\u003ctd\u003e50 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e24100R3-APS\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6630-818\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003ctd\u003e230V 1Ph 3-Wire\u003c\/td\u003e\n\u003ctd\u003ePressure Switch\u003c\/td\u003e\n\u003ctd\u003eSD1-2HP2PS\u003c\/td\u003e\n\u003ctd\u003e109 ft\u003c\/td\u003e\n\u003ctd\u003e170 ft\u003c\/td\u003e\n\u003ctd\u003e49 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e24100R3-APT\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6630-817\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003ctd\u003e230V 1Ph 3-Wire\u003c\/td\u003e\n\u003ctd\u003eTransducer\u003c\/td\u003e\n\u003ctd\u003eSD1-2HP2\u003c\/td\u003e\n\u003ctd\u003e109 ft\u003c\/td\u003e\n\u003ctd\u003e170 ft\u003c\/td\u003e\n\u003ctd\u003e49 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e24100R3Z-APT\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6630-888\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003ctd\u003e230V 3Ph\u003c\/td\u003e\n\u003ctd\u003eTransducer\u003c\/td\u003e\n\u003ctd\u003eSD3-2HP2\u003c\/td\u003e\n\u003ctd\u003e109 ft\u003c\/td\u003e\n\u003ctd\u003e170 ft\u003c\/td\u003e\n\u003ctd\u003e50 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e24150R2-APS\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6630-813\u003c\/td\u003e\n\u003ctd\u003e1 1\/2\u003c\/td\u003e\n\u003ctd\u003e230V 1Ph 2-Wire\u003c\/td\u003e\n\u003ctd\u003ePressure Switch\u003c\/td\u003e\n\u003ctd\u003eSD1-2HP2PS\u003c\/td\u003e\n\u003ctd\u003e149 ft\u003c\/td\u003e\n\u003ctd\u003e230 ft\u003c\/td\u003e\n\u003ctd\u003e56 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e24150R2-APT\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6630-809\u003c\/td\u003e\n\u003ctd\u003e1 1\/2\u003c\/td\u003e\n\u003ctd\u003e230V 1Ph 2-Wire\u003c\/td\u003e\n\u003ctd\u003eTransducer\u003c\/td\u003e\n\u003ctd\u003eSD1-2HP2\u003c\/td\u003e\n\u003ctd\u003e149 ft\u003c\/td\u003e\n\u003ctd\u003e230 ft\u003c\/td\u003e\n\u003ctd\u003e56 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e24150R3-APS\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6630-823\u003c\/td\u003e\n\u003ctd\u003e1 1\/2\u003c\/td\u003e\n\u003ctd\u003e230V 1Ph 3-Wire\u003c\/td\u003e\n\u003ctd\u003ePressure Switch\u003c\/td\u003e\n\u003ctd\u003eSD1-2HP2PS\u003c\/td\u003e\n\u003ctd\u003e149 ft\u003c\/td\u003e\n\u003ctd\u003e230 ft\u003c\/td\u003e\n\u003ctd\u003e55 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e24150R3-APT\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6630-819\u003c\/td\u003e\n\u003ctd\u003e1 1\/2\u003c\/td\u003e\n\u003ctd\u003e230V 1Ph 3-Wire\u003c\/td\u003e\n\u003ctd\u003eTransducer\u003c\/td\u003e\n\u003ctd\u003eSD1-2HP2\u003c\/td\u003e\n\u003ctd\u003e149 ft\u003c\/td\u003e\n\u003ctd\u003e230 ft\u003c\/td\u003e\n\u003ctd\u003e55 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e24150R3Z-APT\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6630-861\u003c\/td\u003e\n\u003ctd\u003e1 1\/2\u003c\/td\u003e\n\u003ctd\u003e230V 3Ph\u003c\/td\u003e\n\u003ctd\u003eTransducer\u003c\/td\u003e\n\u003ctd\u003eSD3-2HP2\u003c\/td\u003e\n\u003ctd\u003e149 ft\u003c\/td\u003e\n\u003ctd\u003e230 ft\u003c\/td\u003e\n\u003ctd\u003e48 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e24200R3-APS\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6630-831\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e230V 1Ph 3-Wire\u003c\/td\u003e\n\u003ctd\u003ePressure Switch\u003c\/td\u003e\n\u003ctd\u003eSD1-2HP2PS\u003c\/td\u003e\n\u003ctd\u003e190 ft\u003c\/td\u003e\n\u003ctd\u003e298 ft\u003c\/td\u003e\n\u003ctd\u003e56 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e24200R3-APT\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6630-827\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e230V 1Ph 3-Wire\u003c\/td\u003e\n\u003ctd\u003eTransducer\u003c\/td\u003e\n\u003ctd\u003eSD1-2HP2\u003c\/td\u003e\n\u003ctd\u003e190 ft\u003c\/td\u003e\n\u003ctd\u003e298 ft\u003c\/td\u003e\n\u003ctd\u003e56 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e24200R3Z-APT\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6630-835\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e230V 3Ph\u003c\/td\u003e\n\u003ctd\u003eTransducer\u003c\/td\u003e\n\u003ctd\u003eSD3-2HP2\u003c\/td\u003e\n\u003ctd\u003e190 ft\u003c\/td\u003e\n\u003ctd\u003e298 ft\u003c\/td\u003e\n\u003ctd\u003e54 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e24300R3Z-APT\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6630-839\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003ctd\u003e230V 3Ph\u003c\/td\u003e\n\u003ctd\u003eTransducer\u003c\/td\u003e\n\u003ctd\u003eSD3-3HP2\u003c\/td\u003e\n\u003ctd\u003e274 ft\u003c\/td\u003e\n\u003ctd\u003e420 ft\u003c\/td\u003e\n\u003ctd\u003e67 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e24500R3Z-APT\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6630-844\u003c\/td\u003e\n\u003ctd\u003e5\u003c\/td\u003e\n\u003ctd\u003e230V 3Ph\u003c\/td\u003e\n\u003ctd\u003eTransducer\u003c\/td\u003e\n\u003ctd\u003eSD3-5HP2\u003c\/td\u003e\n\u003ctd\u003e434 ft\u003c\/td\u003e\n\u003ctd\u003e656 ft\u003c\/td\u003e\n\u003ctd\u003e83 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"font-size:12.5px;color:#9B9EA3;margin-top:8px;line-height:1.55\"\u003eHead at 35 GPM is read from the published AutoPAC curve (Pumps by Baker catalog (Sept 2025, rev 3\/26), p. 157), digitized and rounded down. Shut-off head as printed. Drive per the compatibility table on p. 141 (1 1\/2 HP three-phase builds use the SD3-2HP2). Sources: Pumps by Baker catalog (Sept 2025, rev 3\/26), pp. 141-143 and 157; Baker Pumps and Accessories price list, effective 7\/1\/2026.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eShared Specifications\u003c\/div\u003e\n\u003cdiv class=\"gs-lead\"\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eIncluded\u003c\/td\u003e\n\u003ctd\u003ePump end, Baker 4 in motor, AutoDRIVE drive, and pressure switch or transducer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDischarge\u003c\/td\u003e\n\u003ctd\u003e2 in NPT (female)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCheck valve\u003c\/td\u003e\n\u003ctd\u003eBuilt in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply\u003c\/td\u003e\n\u003ctd\u003e230V single-phase, 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor\u003c\/td\u003e\n\u003ctd\u003eBaker 4 in submersible motor, matched to the pump end horsepower\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrive enclosure\u003c\/td\u003e\n\u003ctd\u003eNEMA Type 3R steel, 12.25 x 9.25 x 4.68 in, 13 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrive operating temperature\u003c\/td\u003e\n\u003ctd\u003e-4 to 122°F; SD3-5HP2 rated to 104°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrive efficiency\u003c\/td\u003e\n\u003ctd\u003e95%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePump energy index (PEI)\u003c\/td\u003e\n\u003ctd\u003e0.81\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertification (pump)\u003c\/td\u003e\n\u003ctd\u003eDrinking Water ANSI\/NSF 61\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApp connection\u003c\/td\u003e\n\u003ctd\u003eNone; set up on the drive display\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"font-size:12.5px;color:#9B9EA3;margin-top:8px;line-height:1.55\"\u003eSource: Pumps by Baker catalog (Sept 2025, rev 3\/26), pp. 131-133 and 141-143.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003ePerformance — Will It Do What You Need?\u003c\/div\u003e\n\u003cdiv class=\"gs-lead\"\u003e\n\u003cp\u003e\u003cstrong\u003eTotal head\u003c\/strong\u003e is everything the pump lifts against: the vertical lift from the pumping water level to the discharge, the pressure you set on the drive (2.31 ft for every PSI), and friction in the drop pipe. The drive slows the pump when demand falls, so the curve below is the most the pump delivers at full speed.\u003c\/p\u003e\n\u003cp style=\"margin-bottom:4px\"\u003e\u003cstrong\u003eTotal head in feet, by flow in GPM, at full speed\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eHP (stages)\u003c\/th\u003e\n\u003cth\u003e0\u003c\/th\u003e\n\u003cth\u003e5\u003c\/th\u003e\n\u003cth\u003e10\u003c\/th\u003e\n\u003cth\u003e15\u003c\/th\u003e\n\u003cth\u003e20\u003c\/th\u003e\n\u003cth\u003e25\u003c\/th\u003e\n\u003cth\u003e30\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003e35\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e40\u003c\/th\u003e\n\u003cth\u003e45\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e1 HP (6)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e179\u003c\/td\u003e\n\u003ctd\u003e174\u003c\/td\u003e\n\u003ctd\u003e168\u003c\/td\u003e\n\u003ctd\u003e162\u003c\/td\u003e\n\u003ctd\u003e154\u003c\/td\u003e\n\u003ctd\u003e143\u003c\/td\u003e\n\u003ctd\u003e128\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e109\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e88\u003c\/td\u003e\n\u003ctd\u003e61\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e1 1\/2 HP (8)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e240\u003c\/td\u003e\n\u003ctd\u003e231\u003c\/td\u003e\n\u003ctd\u003e222\u003c\/td\u003e\n\u003ctd\u003e213\u003c\/td\u003e\n\u003ctd\u003e203\u003c\/td\u003e\n\u003ctd\u003e188\u003c\/td\u003e\n\u003ctd\u003e169\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e149\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e117\u003c\/td\u003e\n\u003ctd\u003e79\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e2 HP (10)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e304\u003c\/td\u003e\n\u003ctd\u003e290\u003c\/td\u003e\n\u003ctd\u003e276\u003c\/td\u003e\n\u003ctd\u003e262\u003c\/td\u003e\n\u003ctd\u003e248\u003c\/td\u003e\n\u003ctd\u003e230\u003c\/td\u003e\n\u003ctd\u003e211\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e190\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e154\u003c\/td\u003e\n\u003ctd\u003e102\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e3 HP (14)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e432\u003c\/td\u003e\n\u003ctd\u003e412\u003c\/td\u003e\n\u003ctd\u003e393\u003c\/td\u003e\n\u003ctd\u003e374\u003c\/td\u003e\n\u003ctd\u003e355\u003c\/td\u003e\n\u003ctd\u003e331\u003c\/td\u003e\n\u003ctd\u003e304\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e274\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e233\u003c\/td\u003e\n\u003ctd\u003e167\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e5 HP (22)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e667\u003c\/td\u003e\n\u003ctd\u003e644\u003c\/td\u003e\n\u003ctd\u003e618\u003c\/td\u003e\n\u003ctd\u003e592\u003c\/td\u003e\n\u003ctd\u003e564\u003c\/td\u003e\n\u003ctd\u003e524\u003c\/td\u003e\n\u003ctd\u003e481\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e434\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e363\u003c\/td\u003e\n\u003ctd\u003e272\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"font-size:12.5px;color:#9B9EA3;margin-top:6px;line-height:1.55\"\u003eDigitized from the published AutoPAC curve in the Pumps by Baker catalog (Sept 2025, rev 3\/26), p. 157, and rounded down. Rated flow (35 GPM) in bold. Zero flow is the shut-off point, a ceiling rather than a working point; — marks flows past the end of that curve.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBest operating range:\u003c\/strong\u003e the published curve shades the most efficient operating range; the catalog prints no figures for it. The curve is in the image gallery.\u003c\/p\u003e\n\u003cdiv style=\"display:flex;flex-wrap:wrap;gap:10px;margin:22px 0 4px\"\u003e\n\u003ca href=\"\/pages\/submersible-well-pump-sizing-calculator\" style=\"flex:1 1 200px;text-align:center;display:block;background:#B3122A;color:#ffffff;font-family:Arial Black,Arial,sans-serif;font-size:12px;text-transform:uppercase;letter-spacing:1.2px;padding:11px 18px;text-decoration:none\"\u003eSubmersible Calculator\u003c\/a\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eBefore You Buy — The Limits That Decide the Fit\u003c\/div\u003e\n\u003cdiv class=\"gs-lead\"\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply\u003c\/td\u003e\n\u003ctd\u003e230V single-phase for every build, from a circuit breaker sized per the table below\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure transducer\u003c\/td\u003e\n\u003ctd\u003eMust be installed upright and vertical (manufacturer note)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrive location\u003c\/td\u003e\n\u003ctd\u003eNEMA 3R enclosure, outdoors or indoors; rated to 122°F (104°F for SD3-5HP2); derate above 5500 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor cooling\u003c\/td\u003e\n\u003ctd\u003e1.0 ft\/sec of water flow past the motor at 95°F; motor rated to 95°F water\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWell size\u003c\/td\u003e\n\u003ctd\u003e4 in casing and larger\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePairing\u003c\/td\u003e\n\u003ctd\u003eOne pump and one drive per well\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"margin:14px 0 4px\"\u003e\u003cstrong\u003eBreaker sizing by motor HP (manufacturer recommendation)\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSupply\u003c\/th\u003e\n\u003cth\u003eMotor HP\u003c\/th\u003e\n\u003cth\u003eInput Current\u003c\/th\u003e\n\u003cth\u003eFuse \/ Breaker\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e230V\u003c\/td\u003e\n\u003ctd\u003e1\/2\u003c\/td\u003e\n\u003ctd\u003e6 A\u003c\/td\u003e\n\u003ctd\u003e10 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e230V\u003c\/td\u003e\n\u003ctd\u003e3\/4\u003c\/td\u003e\n\u003ctd\u003e9 A\u003c\/td\u003e\n\u003ctd\u003e15 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e230V\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003ctd\u003e14 A\u003c\/td\u003e\n\u003ctd\u003e20 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e230V\u003c\/td\u003e\n\u003ctd\u003e1 1\/2\u003c\/td\u003e\n\u003ctd\u003e18 A\u003c\/td\u003e\n\u003ctd\u003e25 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e230V\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e28 A\u003c\/td\u003e\n\u003ctd\u003e35 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e230V\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e20 A\u003c\/td\u003e\n\u003ctd\u003e25 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e230V\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003ctd\u003e30 A\u003c\/td\u003e\n\u003ctd\u003e40 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e230V\u003c\/td\u003e\n\u003ctd\u003e5\u003c\/td\u003e\n\u003ctd\u003e42 A\u003c\/td\u003e\n\u003ctd\u003e55 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"font-size:12.5px;color:#9B9EA3;margin-top:8px;line-height:1.55\"\u003eSource: Pumps by Baker catalog (Sept 2025, rev 3\/26), p. 131.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eMaterials of Construction (Pump)\u003c\/div\u003e\n\u003cdiv class=\"gs-lead\"\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eDischarge head\u003c\/td\u003e\n\u003ctd\u003eStainless steel 304, 2 in NPT discharge\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor adapter\u003c\/td\u003e\n\u003ctd\u003eStainless steel 304, NEMA standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCheck valve\u003c\/td\u003e\n\u003ctd\u003eStainless steel 304\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExternal shell\u003c\/td\u003e\n\u003ctd\u003eStainless steel 304, polished\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eImpellers\u003c\/td\u003e\n\u003ctd\u003eNoryl\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiffusers\u003c\/td\u003e\n\u003ctd\u003ePolycarbonate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBearing\u003c\/td\u003e\n\u003ctd\u003ePolyacetal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShaft coupling\u003c\/td\u003e\n\u003ctd\u003eStainless steel 304, NEMA standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStrainer\u003c\/td\u003e\n\u003ctd\u003eStainless steel 304\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShaft\u003c\/td\u003e\n\u003ctd\u003eStainless steel 304\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable guard\u003c\/td\u003e\n\u003ctd\u003eStainless steel 304\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"font-size:12.5px;color:#9B9EA3;margin-top:8px;line-height:1.55\"\u003eSource: Pumps by Baker catalog (Sept 2025, rev 3\/26), pp. 79-80.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eService Parts\u003c\/div\u003e\n\u003cdiv class=\"gs-lead\"\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003ePart\u003c\/th\u003e\n\u003cth\u003ePart No.\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutoDRIVE pressure transducer with 10 ft wire\u003c\/td\u003e\n\u003ctd\u003e6619-028\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutoDRIVE pressure switch with wire\u003c\/td\u003e\n\u003ctd\u003e6619-029\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutoDRIVE keypad\u003c\/td\u003e\n\u003ctd\u003e6619-030\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"font-size:12.5px;color:#9B9EA3;margin-top:8px;line-height:1.55\"\u003eSource: Pumps by Baker catalog (Sept 2025, rev 3\/26), pp. 142-143.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"gs-contact\"\u003eFor engineering-led sizing and selection support or a factory submittal, email \u003ca href=\"mailto:sales@watermainsupply.com\"\u003esales@watermainsupply.com\u003c\/a\u003e or call \u003ca href=\"tel:18885104036\"\u003e1-888.510.4036\u003c\/a\u003e.\u003cbr\u003e© Watermain Supply — A division of E4 Industrial LLC\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch5\u003eData Sheet\u003c\/h5\u003e\n\u003cdiv class=\"gs\"\u003e\n\u003cdiv class=\"gs-dl\"\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0264\/1913\/4527\/files\/AutoPac_Guide.pdf?v=1772502299\" target=\"_blank\" rel=\"noopener\"\u003ePumps by Baker AutoPac Guide\u003c\/a\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch5\u003eVideos\u003c\/h5\u003e\n\u003cdiv class=\"gs\"\u003e\u003cdiv class=\"gs-sec\" style=\"margin-top:6px\"\u003e\n\u003cp style=\"font-size:13px;color:#9B9EA3\"\u003eProduct videos are being added to this listing. For a walkthrough in the meantime, email sales@watermainsupply.com.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003c!-- \/TABS --\u003e","brand":"A.Y. McDonald","offers":[{"title":"1 HP - 4 in Motor \/ 230V 1Ph 2-Wire \/ Switch - 24100R2-APS - 109 ft at 35 GPM","offer_id":46602934354095,"sku":"6630-808","price":2527.56,"currency_code":"USD","in_stock":true},{"title":"1 HP - 4 in Motor \/ 230V 1Ph 2-Wire \/ Transducer - 24100R2-APT - 109 ft at 35 GPM","offer_id":46602934419631,"sku":"6630-807","price":2706.47,"currency_code":"USD","in_stock":true},{"title":"1 HP - 4 in Motor \/ 230V 1Ph 3-Wire \/ Switch - 24100R3-APS - 109 ft at 35 GPM","offer_id":46602934485167,"sku":"6630-818","price":2428.92,"currency_code":"USD","in_stock":true},{"title":"1 HP - 4 in Motor \/ 230V 1Ph 3-Wire \/ Transducer - 24100R3-APT - 109 ft at 35 GPM","offer_id":46602934583471,"sku":"6630-817","price":2608.33,"currency_code":"USD","in_stock":true},{"title":"1 HP - 4 in Motor \/ 230V 3Ph \/ Transducer - 24100R3Z-APT - 109 ft at 35 GPM","offer_id":46602934681775,"sku":"6630-888","price":2875.64,"currency_code":"USD","in_stock":true},{"title":"1 1\/2 HP - 4 in Motor \/ 230V 1Ph 2-Wire \/ Switch - 24150R2-APS - 149 ft at 35 GPM","offer_id":46602934386863,"sku":"6630-813","price":2700.89,"currency_code":"USD","in_stock":true},{"title":"1 1\/2 HP - 4 in Motor \/ 230V 1Ph 2-Wire \/ Transducer - 24150R2-APT - 149 ft at 35 GPM","offer_id":46602934452399,"sku":"6630-809","price":2879.26,"currency_code":"USD","in_stock":true},{"title":"1 1\/2 HP - 4 in Motor \/ 230V 1Ph 3-Wire \/ Switch - 24150R3-APS - 149 ft at 35 GPM","offer_id":46602934517935,"sku":"6630-823","price":2516.87,"currency_code":"USD","in_stock":true},{"title":"1 1\/2 HP - 4 in Motor \/ 230V 1Ph 3-Wire \/ Transducer - 24150R3-APT - 149 ft at 35 GPM","offer_id":46602934616239,"sku":"6630-819","price":2695.77,"currency_code":"USD","in_stock":true},{"title":"1 1\/2 HP - 4 in Motor \/ 230V 3Ph \/ Transducer - 24150R3Z-APT - 149 ft at 35 GPM","offer_id":46602934714543,"sku":"6630-861","price":2917.05,"currency_code":"USD","in_stock":true},{"title":"2 HP - 4 in Motor \/ 230V 1Ph 3-Wire \/ Switch - 24200R3-APS - 190 ft at 35 GPM","offer_id":46602934550703,"sku":"6630-831","price":2763.23,"currency_code":"USD","in_stock":true},{"title":"2 HP - 4 in Motor \/ 230V 1Ph 3-Wire \/ Transducer - 24200R3-APT - 190 ft at 35 GPM","offer_id":46602934649007,"sku":"6630-827","price":2941.11,"currency_code":"USD","in_stock":true},{"title":"2 HP - 4 in Motor \/ 230V 3Ph \/ Transducer - 24200R3Z-APT - 190 ft at 35 GPM","offer_id":46602934747311,"sku":"6630-835","price":3158.86,"currency_code":"USD","in_stock":true},{"title":"3 HP - 4 in Motor \/ 230V 3Ph \/ Transducer - 24300R3Z-APT - 274 ft at 35 GPM","offer_id":46602934780079,"sku":"6630-839","price":3905.1,"currency_code":"USD","in_stock":true},{"title":"5 HP - 4 in Motor \/ 230V 3Ph \/ Transducer - 24500R3Z-APT - 434 ft at 35 GPM","offer_id":46602934812847,"sku":"6630-844","price":5569.94,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0264\/1913\/4527\/files\/AutoPac_651f413e-f10c-4e78-9075-1422c2570d18.png?v=1772502616"},{"product_id":"baker-autopac-g-40-gpm-24000-series","title":"A.Y. McDonald AutoPAC G - 40 GPM 24000 Constant Pressure Pump","description":"\u003c!-- TABS --\u003e\n\u003ch5\u003eDescription\u003c\/h5\u003e\n\u003cdiv class=\"gs\"\u003e\n\u003cdiv class=\"gs-head\"\u003e\n\u003cdiv class=\"gs-eyebrow\"\u003eA.Y. McDonald · Constant Pressure Pump System\u003c\/div\u003e\n\u003cdiv class=\"gs-title\"\u003eAutoPAC G - 40 GPM, 24000 Series High Flow\u003c\/div\u003e\n\u003cdiv class=\"gs-sub\"\u003eBaker stainless steel 4 in submersible pump, motor and AutoDRIVE constant pressure drive, 1 1\/2 to 5 HP, 10 builds.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"gs-badges\"\u003e\n\u003cdiv class=\"gs-badge\" style=\"background:#B3122A;color:#FFFFFF;border-color:#B3122A\"\u003e109-334 ft at 40 GPM\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003e1 1\/2-5 HP\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003e230V Single-Phase Supply\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003eAutoDRIVE Constant Pressure VFD\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003ePressure Switch or Transducer Control\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003e423 ft Max Head (Shut-off)\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003e2 in NPT Discharge\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003eNEMA 3R Drive Enclosure\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003eDrinking Water ANSI\/NSF 61\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003e46-78 lb Weight\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background:#FFFFFF;border:1px solid #C7CBD1;border-top:3px solid #B3122A;padding:12px 16px 12px;margin:16px 0 4px;font-size:13.5px;line-height:1.55;color:#4A4A4F\"\u003e\n\u003cdiv style=\"font-family:Arial Black,Arial,sans-serif;font-size:11px;letter-spacing:1.2px;text-transform:uppercase;color:#B3122A;margin-bottom:8px\"\u003eWhat Ships and What It Needs to Run\u003c\/div\u003e\n\u003cp style=\"margin:0 0 6px\"\u003e\u003cstrong style=\"color:#B3122A\"\u003eIncluded:\u003c\/strong\u003e the pump end and Baker 4 in motor, assembled, with the AutoDRIVE constant pressure drive matched to the motor, and the pressure switch (APS models) or pressure transducer with 10 ft wire (APT models). The drive model for each build is in the Models table.\u003c\/p\u003e\n\u003cp style=\"margin:0 0 6px\"\u003e\u003cstrong style=\"color:#B3122A\"\u003ePower:\u003c\/strong\u003e 230V single-phase supply from a circuit breaker for every build; the three-phase builds take single-phase power and the drive makes three-phase for the motor. Breaker sizes are under Before You Buy.\u003c\/p\u003e\n\u003cp style=\"margin:0\"\u003e\u003cstrong style=\"color:#B3122A\"\u003eSized at install:\u003c\/strong\u003e drop cable, splice kit and the pressure relief valve shown in the manufacturer’s installation diagram.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eOverview\u003c\/div\u003e\n\u003cdiv class=\"gs-lead\"\u003e\n\u003cp\u003eThe AutoPAC is Baker’s constant pressure well package: a 24000 Series High Flow 4 in submersible pump, a Baker motor of the same horsepower, and the AutoDRIVE variable frequency drive. The drive holds a set pressure by changing the pump speed, which allows a smaller pressure tank and a quick, simple installation; setup takes 5 steps or less on the drive’s backlit display.\u003c\/p\u003e\n\u003cp\u003eThis listing is the \u003cstrong\u003eG - 40 GPM\u003c\/strong\u003e class: 1 1\/2 to 5 HP, with pressure switch and transducer control. The AutoDRIVE is American made and housed in a NEMA 3R steel enclosure rated for outdoor use.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background:#E1E3E6;border-left:3px solid #B8BDC4;padding:8px 14px;font-size:11.5px;color:#4A4A4F;margin-top:14px;line-height:1.5\"\u003eGenuine A.Y. McDonald equipment, factory-new in original packaging — sold and supported by Watermain Supply, an independent industrial supplier. Watermain Supply is an Authorized Stocking A.Y. McDonald and Baker Water Systems Distributor.\u003c\/div\u003e\n\u003cdiv style=\"background:#fff;border-left:5px solid #B3122A;padding:15px 18px;margin-top:12px\"\u003e\n\u003cdiv style=\"font-family:Arial Black,Arial,sans-serif;font-size:15px;color:#B3122A;text-transform:uppercase;letter-spacing:1px;margin-bottom:6px\"\u003eA.Y. McDonald Warranty\u003c\/div\u003e\n\u003cp style=\"margin:0;font-size:13.5px;color:#4A4A4F;line-height:1.55\"\u003ePump and motor: covered for \u003cstrong\u003e3 years from the date of manufacture\u003c\/strong\u003e under A.Y. McDonald’s published terms for Baker submersible motors and assembled submersible pumps with pump ends up to 80 GPM. The AutoDRIVE and pressure control fall under A.Y. McDonald’s standard limited warranty: 2 years from the date of manufacture or 1 year from installation, whichever comes first.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eRoom to Grow\u003c\/div\u003e\n\u003cdiv class=\"gs-lead\"\u003e\n\u003cp\u003eOne pump and one drive per well. Need more head later? Step up in horsepower within the G - 40 GPM class; the drive model changes with the motor (see the Models table). Need more flow? Move to a higher flow class of the AutoPAC 24000 Series; every class uses the same 2 in NPT discharge.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eModels \u0026amp; Ratings (60 Hz)\u003c\/div\u003e\n\u003cdiv class=\"gs-lead\"\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003cth\u003ePart No.\u003c\/th\u003e\n\u003cth\u003eHP\u003c\/th\u003e\n\u003cth\u003eMotor\u003c\/th\u003e\n\u003cth\u003eControl\u003c\/th\u003e\n\u003cth\u003eAutoDRIVE\u003c\/th\u003e\n\u003cth\u003eHead at 40 GPM\u003c\/th\u003e\n\u003cth\u003eShut-off Head\u003c\/th\u003e\n\u003cth\u003eWeight\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e24150G2-APS\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6630-814\u003c\/td\u003e\n\u003ctd\u003e1 1\/2\u003c\/td\u003e\n\u003ctd\u003e230V 1Ph 2-Wire\u003c\/td\u003e\n\u003ctd\u003ePressure Switch\u003c\/td\u003e\n\u003ctd\u003eSD1-2HP2PS\u003c\/td\u003e\n\u003ctd\u003e109 ft\u003c\/td\u003e\n\u003ctd\u003e151 ft\u003c\/td\u003e\n\u003ctd\u003e54 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e24150G2-APT\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6630-810\u003c\/td\u003e\n\u003ctd\u003e1 1\/2\u003c\/td\u003e\n\u003ctd\u003e230V 1Ph 2-Wire\u003c\/td\u003e\n\u003ctd\u003eTransducer\u003c\/td\u003e\n\u003ctd\u003eSD1-2HP2\u003c\/td\u003e\n\u003ctd\u003e109 ft\u003c\/td\u003e\n\u003ctd\u003e151 ft\u003c\/td\u003e\n\u003ctd\u003e54 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e24150G3-APS\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6630-824\u003c\/td\u003e\n\u003ctd\u003e1 1\/2\u003c\/td\u003e\n\u003ctd\u003e230V 1Ph 3-Wire\u003c\/td\u003e\n\u003ctd\u003ePressure Switch\u003c\/td\u003e\n\u003ctd\u003eSD1-2HP2PS\u003c\/td\u003e\n\u003ctd\u003e109 ft\u003c\/td\u003e\n\u003ctd\u003e151 ft\u003c\/td\u003e\n\u003ctd\u003e53 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e24150G3-APT\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6630-820\u003c\/td\u003e\n\u003ctd\u003e1 1\/2\u003c\/td\u003e\n\u003ctd\u003e230V 1Ph 3-Wire\u003c\/td\u003e\n\u003ctd\u003eTransducer\u003c\/td\u003e\n\u003ctd\u003eSD1-2HP2\u003c\/td\u003e\n\u003ctd\u003e109 ft\u003c\/td\u003e\n\u003ctd\u003e151 ft\u003c\/td\u003e\n\u003ctd\u003e53 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e24150G3Z-APT\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6630-862\u003c\/td\u003e\n\u003ctd\u003e1 1\/2\u003c\/td\u003e\n\u003ctd\u003e230V 3Ph\u003c\/td\u003e\n\u003ctd\u003eTransducer\u003c\/td\u003e\n\u003ctd\u003eSD3-2HP2\u003c\/td\u003e\n\u003ctd\u003e109 ft\u003c\/td\u003e\n\u003ctd\u003e151 ft\u003c\/td\u003e\n\u003ctd\u003e46 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e24200G3-APS\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6630-832\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e230V 1Ph 3-Wire\u003c\/td\u003e\n\u003ctd\u003ePressure Switch\u003c\/td\u003e\n\u003ctd\u003eSD1-2HP2PS\u003c\/td\u003e\n\u003ctd\u003e129 ft\u003c\/td\u003e\n\u003ctd\u003e180 ft\u003c\/td\u003e\n\u003ctd\u003e54 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e24200G3-APT\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6630-828\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e230V 1Ph 3-Wire\u003c\/td\u003e\n\u003ctd\u003eTransducer\u003c\/td\u003e\n\u003ctd\u003eSD1-2HP2\u003c\/td\u003e\n\u003ctd\u003e129 ft\u003c\/td\u003e\n\u003ctd\u003e180 ft\u003c\/td\u003e\n\u003ctd\u003e54 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e24200G3Z-APT\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6630-836\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e230V 3Ph\u003c\/td\u003e\n\u003ctd\u003eTransducer\u003c\/td\u003e\n\u003ctd\u003eSD3-2HP2\u003c\/td\u003e\n\u003ctd\u003e129 ft\u003c\/td\u003e\n\u003ctd\u003e180 ft\u003c\/td\u003e\n\u003ctd\u003e52 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e24300G3Z-APT\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6630-840\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003ctd\u003e230V 3Ph\u003c\/td\u003e\n\u003ctd\u003eTransducer\u003c\/td\u003e\n\u003ctd\u003eSD3-3HP2\u003c\/td\u003e\n\u003ctd\u003e188 ft\u003c\/td\u003e\n\u003ctd\u003e243 ft\u003c\/td\u003e\n\u003ctd\u003e63 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e24500G3Z-APT\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6630-845\u003c\/td\u003e\n\u003ctd\u003e5\u003c\/td\u003e\n\u003ctd\u003e230V 3Ph\u003c\/td\u003e\n\u003ctd\u003eTransducer\u003c\/td\u003e\n\u003ctd\u003eSD3-5HP2\u003c\/td\u003e\n\u003ctd\u003e334 ft\u003c\/td\u003e\n\u003ctd\u003e423 ft\u003c\/td\u003e\n\u003ctd\u003e78 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"font-size:12.5px;color:#9B9EA3;margin-top:8px;line-height:1.55\"\u003eHead at 40 GPM is read from the published AutoPAC curve (Pumps by Baker catalog (Sept 2025, rev 3\/26), p. 158), digitized and rounded down. Shut-off head as printed. Drive per the compatibility table on p. 141 (1 1\/2 HP three-phase builds use the SD3-2HP2). Sources: Pumps by Baker catalog (Sept 2025, rev 3\/26), pp. 141-143 and 158; Baker Pumps and Accessories price list, effective 7\/1\/2026.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eShared Specifications\u003c\/div\u003e\n\u003cdiv class=\"gs-lead\"\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eIncluded\u003c\/td\u003e\n\u003ctd\u003ePump end, Baker 4 in motor, AutoDRIVE drive, and pressure switch or transducer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDischarge\u003c\/td\u003e\n\u003ctd\u003e2 in NPT (female)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCheck valve\u003c\/td\u003e\n\u003ctd\u003eBuilt in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply\u003c\/td\u003e\n\u003ctd\u003e230V single-phase, 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor\u003c\/td\u003e\n\u003ctd\u003eBaker 4 in submersible motor, matched to the pump end horsepower\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrive enclosure\u003c\/td\u003e\n\u003ctd\u003eNEMA Type 3R steel, 12.25 x 9.25 x 4.68 in, 13 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrive operating temperature\u003c\/td\u003e\n\u003ctd\u003e-4 to 122°F; SD3-5HP2 rated to 104°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrive efficiency\u003c\/td\u003e\n\u003ctd\u003e95%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePump energy index (PEI)\u003c\/td\u003e\n\u003ctd\u003e0.97\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertification (pump)\u003c\/td\u003e\n\u003ctd\u003eDrinking Water ANSI\/NSF 61\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApp connection\u003c\/td\u003e\n\u003ctd\u003eNone; set up on the drive display\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"font-size:12.5px;color:#9B9EA3;margin-top:8px;line-height:1.55\"\u003eSource: Pumps by Baker catalog (Sept 2025, rev 3\/26), pp. 131-133 and 141-143.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003ePerformance — Will It Do What You Need?\u003c\/div\u003e\n\u003cdiv class=\"gs-lead\"\u003e\n\u003cp\u003e\u003cstrong\u003eTotal head\u003c\/strong\u003e is everything the pump lifts against: the vertical lift from the pumping water level to the discharge, the pressure you set on the drive (2.31 ft for every PSI), and friction in the drop pipe. The drive slows the pump when demand falls, so the curve below is the most the pump delivers at full speed.\u003c\/p\u003e\n\u003cp style=\"margin-bottom:4px\"\u003e\u003cstrong\u003eTotal head in feet, by flow in GPM, at full speed\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eHP (stages)\u003c\/th\u003e\n\u003cth\u003e0\u003c\/th\u003e\n\u003cth\u003e10\u003c\/th\u003e\n\u003cth\u003e20\u003c\/th\u003e\n\u003cth\u003e30\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003e40\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e50\u003c\/th\u003e\n\u003cth\u003e60\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e1 1\/2 HP (5)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e149\u003c\/td\u003e\n\u003ctd\u003e142\u003c\/td\u003e\n\u003ctd\u003e134\u003c\/td\u003e\n\u003ctd\u003e122\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e109\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e90\u003c\/td\u003e\n\u003ctd\u003e65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e2 HP (6)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e183\u003c\/td\u003e\n\u003ctd\u003e174\u003c\/td\u003e\n\u003ctd\u003e164\u003c\/td\u003e\n\u003ctd\u003e148\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e129\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e106\u003c\/td\u003e\n\u003ctd\u003e77\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e3 HP (8)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e248\u003c\/td\u003e\n\u003ctd\u003e242\u003c\/td\u003e\n\u003ctd\u003e231\u003c\/td\u003e\n\u003ctd\u003e213\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e188\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e156\u003c\/td\u003e\n\u003ctd\u003e111\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e5 HP (14)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e428\u003c\/td\u003e\n\u003ctd\u003e415\u003c\/td\u003e\n\u003ctd\u003e395\u003c\/td\u003e\n\u003ctd\u003e368\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e334\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e286\u003c\/td\u003e\n\u003ctd\u003e218\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"font-size:12.5px;color:#9B9EA3;margin-top:6px;line-height:1.55\"\u003eDigitized from the published AutoPAC curve in the Pumps by Baker catalog (Sept 2025, rev 3\/26), p. 158, and rounded down. Rated flow (40 GPM) in bold. Zero flow is the shut-off point, a ceiling rather than a working point; — marks flows past the end of that curve.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBest operating range:\u003c\/strong\u003e the published curve shades the most efficient operating range; the catalog prints no figures for it. The curve is in the image gallery.\u003c\/p\u003e\n\u003cdiv style=\"display:flex;flex-wrap:wrap;gap:10px;margin:22px 0 4px\"\u003e\n\u003ca href=\"\/pages\/submersible-well-pump-sizing-calculator\" style=\"flex:1 1 200px;text-align:center;display:block;background:#B3122A;color:#ffffff;font-family:Arial Black,Arial,sans-serif;font-size:12px;text-transform:uppercase;letter-spacing:1.2px;padding:11px 18px;text-decoration:none\"\u003eSubmersible Calculator\u003c\/a\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eBefore You Buy — The Limits That Decide the Fit\u003c\/div\u003e\n\u003cdiv class=\"gs-lead\"\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply\u003c\/td\u003e\n\u003ctd\u003e230V single-phase for every build, from a circuit breaker sized per the table below\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure transducer\u003c\/td\u003e\n\u003ctd\u003eMust be installed upright and vertical (manufacturer note)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrive location\u003c\/td\u003e\n\u003ctd\u003eNEMA 3R enclosure, outdoors or indoors; rated to 122°F (104°F for SD3-5HP2); derate above 5500 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor cooling\u003c\/td\u003e\n\u003ctd\u003e1.0 ft\/sec of water flow past the motor at 95°F; motor rated to 95°F water\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWell size\u003c\/td\u003e\n\u003ctd\u003e4 in casing and larger\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePairing\u003c\/td\u003e\n\u003ctd\u003eOne pump and one drive per well\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"margin:14px 0 4px\"\u003e\u003cstrong\u003eBreaker sizing by motor HP (manufacturer recommendation)\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSupply\u003c\/th\u003e\n\u003cth\u003eMotor HP\u003c\/th\u003e\n\u003cth\u003eInput Current\u003c\/th\u003e\n\u003cth\u003eFuse \/ Breaker\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e230V\u003c\/td\u003e\n\u003ctd\u003e1\/2\u003c\/td\u003e\n\u003ctd\u003e6 A\u003c\/td\u003e\n\u003ctd\u003e10 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e230V\u003c\/td\u003e\n\u003ctd\u003e3\/4\u003c\/td\u003e\n\u003ctd\u003e9 A\u003c\/td\u003e\n\u003ctd\u003e15 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e230V\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003ctd\u003e14 A\u003c\/td\u003e\n\u003ctd\u003e20 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e230V\u003c\/td\u003e\n\u003ctd\u003e1 1\/2\u003c\/td\u003e\n\u003ctd\u003e18 A\u003c\/td\u003e\n\u003ctd\u003e25 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e230V\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e28 A\u003c\/td\u003e\n\u003ctd\u003e35 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e230V\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e20 A\u003c\/td\u003e\n\u003ctd\u003e25 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e230V\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003ctd\u003e30 A\u003c\/td\u003e\n\u003ctd\u003e40 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e230V\u003c\/td\u003e\n\u003ctd\u003e5\u003c\/td\u003e\n\u003ctd\u003e42 A\u003c\/td\u003e\n\u003ctd\u003e55 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"font-size:12.5px;color:#9B9EA3;margin-top:8px;line-height:1.55\"\u003eSource: Pumps by Baker catalog (Sept 2025, rev 3\/26), p. 131.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eMaterials of Construction (Pump)\u003c\/div\u003e\n\u003cdiv class=\"gs-lead\"\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eDischarge head\u003c\/td\u003e\n\u003ctd\u003eStainless steel 304, 2 in NPT discharge\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor adapter\u003c\/td\u003e\n\u003ctd\u003eStainless steel 304, NEMA standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCheck valve\u003c\/td\u003e\n\u003ctd\u003eStainless steel 304\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExternal shell\u003c\/td\u003e\n\u003ctd\u003eStainless steel 304, polished\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eImpellers\u003c\/td\u003e\n\u003ctd\u003eNoryl\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiffusers\u003c\/td\u003e\n\u003ctd\u003ePolycarbonate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBearing\u003c\/td\u003e\n\u003ctd\u003ePolyacetal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShaft coupling\u003c\/td\u003e\n\u003ctd\u003eStainless steel 304, NEMA standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStrainer\u003c\/td\u003e\n\u003ctd\u003eStainless steel 304\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShaft\u003c\/td\u003e\n\u003ctd\u003eStainless steel 304\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable guard\u003c\/td\u003e\n\u003ctd\u003eStainless steel 304\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"font-size:12.5px;color:#9B9EA3;margin-top:8px;line-height:1.55\"\u003eSource: Pumps by Baker catalog (Sept 2025, rev 3\/26), pp. 79-80.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eService Parts\u003c\/div\u003e\n\u003cdiv class=\"gs-lead\"\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003ePart\u003c\/th\u003e\n\u003cth\u003ePart No.\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutoDRIVE pressure transducer with 10 ft wire\u003c\/td\u003e\n\u003ctd\u003e6619-028\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutoDRIVE pressure switch with wire\u003c\/td\u003e\n\u003ctd\u003e6619-029\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutoDRIVE keypad\u003c\/td\u003e\n\u003ctd\u003e6619-030\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"font-size:12.5px;color:#9B9EA3;margin-top:8px;line-height:1.55\"\u003eSource: Pumps by Baker catalog (Sept 2025, rev 3\/26), pp. 142-143.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"gs-contact\"\u003eFor engineering-led sizing and selection support or a factory submittal, email \u003ca href=\"mailto:sales@watermainsupply.com\"\u003esales@watermainsupply.com\u003c\/a\u003e or call \u003ca href=\"tel:18885104036\"\u003e1-888.510.4036\u003c\/a\u003e.\u003cbr\u003e© Watermain Supply — A division of E4 Industrial LLC\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch5\u003eData Sheet\u003c\/h5\u003e\n\u003cdiv class=\"gs\"\u003e\n\u003cdiv class=\"gs-dl\"\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0264\/1913\/4527\/files\/AutoPac_Guide.pdf?v=1772502299\" target=\"_blank\" rel=\"noopener\"\u003ePumps by Baker AutoPac Guide\u003c\/a\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch5\u003eVideos\u003c\/h5\u003e\n\u003cdiv class=\"gs\"\u003e\u003cdiv class=\"gs-sec\" style=\"margin-top:6px\"\u003e\n\u003cp style=\"font-size:13px;color:#9B9EA3\"\u003eProduct videos are being added to this listing. For a walkthrough in the meantime, email sales@watermainsupply.com.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003c!-- \/TABS --\u003e","brand":"A.Y. McDonald","offers":[{"title":"1 1\/2 HP - 4 in Motor \/ 230V 1Ph 2-Wire \/ Switch - 24150G2-APS - 109 ft at 40 GPM","offer_id":46602934845615,"sku":"6630-814","price":2865.46,"currency_code":"USD","in_stock":true},{"title":"1 1\/2 HP - 4 in Motor \/ 230V 1Ph 2-Wire \/ Transducer - 24150G2-APT - 109 ft at 40 GPM","offer_id":46602934878383,"sku":"6630-810","price":3044.87,"currency_code":"USD","in_stock":true},{"title":"1 1\/2 HP - 4 in Motor \/ 230V 1Ph 3-Wire \/ Switch - 24150G3-APS - 109 ft at 40 GPM","offer_id":46602934911151,"sku":"6630-824","price":2682.48,"currency_code":"USD","in_stock":true},{"title":"1 1\/2 HP - 4 in Motor \/ 230V 1Ph 3-Wire \/ Transducer - 24150G3-APT - 109 ft at 40 GPM","offer_id":46602934976687,"sku":"6630-820","price":2860.86,"currency_code":"USD","in_stock":true},{"title":"1 1\/2 HP - 4 in Motor \/ 230V 3Ph \/ Transducer - 24150G3Z-APT - 109 ft at 40 GPM","offer_id":46602935042223,"sku":"6630-862","price":3083.16,"currency_code":"USD","in_stock":true},{"title":"2 HP - 4 in Motor \/ 230V 1Ph 3-Wire \/ Switch - 24200G3-APS - 129 ft at 40 GPM","offer_id":46602934943919,"sku":"6630-832","price":2889.49,"currency_code":"USD","in_stock":true},{"title":"2 HP - 4 in Motor \/ 230V 1Ph 3-Wire \/ Transducer - 24200G3-APT - 129 ft at 40 GPM","offer_id":46602935009455,"sku":"6630-828","price":3068.38,"currency_code":"USD","in_stock":true},{"title":"2 HP - 4 in Motor \/ 230V 3Ph \/ Transducer - 24200G3Z-APT - 129 ft at 40 GPM","offer_id":46602935074991,"sku":"6630-836","price":3286.12,"currency_code":"USD","in_stock":true},{"title":"3 HP - 4 in Motor \/ 230V 3Ph \/ Transducer - 24300G3Z-APT - 188 ft at 40 GPM","offer_id":46602935107759,"sku":"6630-840","price":4079.4,"currency_code":"USD","in_stock":true},{"title":"5 HP - 4 in Motor \/ 230V 3Ph \/ Transducer - 24500G3Z-APT - 334 ft at 40 GPM","offer_id":46602935140527,"sku":"6630-845","price":5821.41,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0264\/1913\/4527\/files\/AutoPac_28e4ed68-f0f2-4cef-8a19-73392b35da28.png?v=1772502618"},{"product_id":"baker-autopac-s-55-gpm-24000-series","title":"A.Y. McDonald AutoPAC S - 55 GPM 24000 Constant Pressure Pump","description":"\u003c!-- TABS --\u003e\n\u003ch5\u003eDescription\u003c\/h5\u003e\n\u003cdiv class=\"gs\"\u003e\n\u003cdiv class=\"gs-head\"\u003e\n\u003cdiv class=\"gs-eyebrow\"\u003eA.Y. McDonald · Constant Pressure Pump System\u003c\/div\u003e\n\u003cdiv class=\"gs-title\"\u003eAutoPAC S - 55 GPM, 24000 Series High Flow\u003c\/div\u003e\n\u003cdiv class=\"gs-sub\"\u003eBaker stainless steel 4 in submersible pump, motor and AutoDRIVE constant pressure drive, 1 1\/2 to 5 HP, 10 builds.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"gs-badges\"\u003e\n\u003cdiv class=\"gs-badge\" style=\"background:#B3122A;color:#FFFFFF;border-color:#B3122A\"\u003e78-250 ft at 55 GPM\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003e1 1\/2-5 HP\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003e230V Single-Phase Supply\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003eAutoDRIVE Constant Pressure VFD\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003ePressure Switch or Transducer Control\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003e420 ft Max Head (Shut-off)\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003e2 in NPT Discharge\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003eNEMA 3R Drive Enclosure\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003eDrinking Water ANSI\/NSF 61\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003e49-85 lb Weight\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background:#FFFFFF;border:1px solid #C7CBD1;border-top:3px solid #B3122A;padding:12px 16px 12px;margin:16px 0 4px;font-size:13.5px;line-height:1.55;color:#4A4A4F\"\u003e\n\u003cdiv style=\"font-family:Arial Black,Arial,sans-serif;font-size:11px;letter-spacing:1.2px;text-transform:uppercase;color:#B3122A;margin-bottom:8px\"\u003eWhat Ships and What It Needs to Run\u003c\/div\u003e\n\u003cp style=\"margin:0 0 6px\"\u003e\u003cstrong style=\"color:#B3122A\"\u003eIncluded:\u003c\/strong\u003e the pump end and Baker 4 in motor, assembled, with the AutoDRIVE constant pressure drive matched to the motor, and the pressure switch (APS models) or pressure transducer with 10 ft wire (APT models). The drive model for each build is in the Models table.\u003c\/p\u003e\n\u003cp style=\"margin:0 0 6px\"\u003e\u003cstrong style=\"color:#B3122A\"\u003ePower:\u003c\/strong\u003e 230V single-phase supply from a circuit breaker for every build; the three-phase builds take single-phase power and the drive makes three-phase for the motor. Breaker sizes are under Before You Buy.\u003c\/p\u003e\n\u003cp style=\"margin:0\"\u003e\u003cstrong style=\"color:#B3122A\"\u003eSized at install:\u003c\/strong\u003e drop cable, splice kit and the pressure relief valve shown in the manufacturer’s installation diagram.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eOverview\u003c\/div\u003e\n\u003cdiv class=\"gs-lead\"\u003e\n\u003cp\u003eThe AutoPAC is Baker’s constant pressure well package: a 24000 Series High Flow 4 in submersible pump, a Baker motor of the same horsepower, and the AutoDRIVE variable frequency drive. The drive holds a set pressure by changing the pump speed, which allows a smaller pressure tank and a quick, simple installation; setup takes 5 steps or less on the drive’s backlit display.\u003c\/p\u003e\n\u003cp\u003eThis listing is the \u003cstrong\u003eS - 55 GPM\u003c\/strong\u003e class: 1 1\/2 to 5 HP, with pressure switch and transducer control. The AutoDRIVE is American made and housed in a NEMA 3R steel enclosure rated for outdoor use.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background:#E1E3E6;border-left:3px solid #B8BDC4;padding:8px 14px;font-size:11.5px;color:#4A4A4F;margin-top:14px;line-height:1.5\"\u003eGenuine A.Y. McDonald equipment, factory-new in original packaging — sold and supported by Watermain Supply, an independent industrial supplier. Watermain Supply is an Authorized Stocking A.Y. McDonald and Baker Water Systems Distributor.\u003c\/div\u003e\n\u003cdiv style=\"background:#fff;border-left:5px solid #B3122A;padding:15px 18px;margin-top:12px\"\u003e\n\u003cdiv style=\"font-family:Arial Black,Arial,sans-serif;font-size:15px;color:#B3122A;text-transform:uppercase;letter-spacing:1px;margin-bottom:6px\"\u003eA.Y. McDonald Warranty\u003c\/div\u003e\n\u003cp style=\"margin:0;font-size:13.5px;color:#4A4A4F;line-height:1.55\"\u003ePump and motor: covered for \u003cstrong\u003e3 years from the date of manufacture\u003c\/strong\u003e under A.Y. McDonald’s published terms for Baker submersible motors and assembled submersible pumps with pump ends up to 80 GPM. The AutoDRIVE and pressure control fall under A.Y. McDonald’s standard limited warranty: 2 years from the date of manufacture or 1 year from installation, whichever comes first.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eRoom to Grow\u003c\/div\u003e\n\u003cdiv class=\"gs-lead\"\u003e\n\u003cp\u003eOne pump and one drive per well. Need more head later? Step up in horsepower within the S - 55 GPM class; the drive model changes with the motor (see the Models table). Need more flow? Move to a higher flow class of the AutoPAC 24000 Series; every class uses the same 2 in NPT discharge.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eModels \u0026amp; Ratings (60 Hz)\u003c\/div\u003e\n\u003cdiv class=\"gs-lead\"\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003cth\u003ePart No.\u003c\/th\u003e\n\u003cth\u003eHP\u003c\/th\u003e\n\u003cth\u003eMotor\u003c\/th\u003e\n\u003cth\u003eControl\u003c\/th\u003e\n\u003cth\u003eAutoDRIVE\u003c\/th\u003e\n\u003cth\u003eHead at 55 GPM\u003c\/th\u003e\n\u003cth\u003eShut-off Head\u003c\/th\u003e\n\u003cth\u003eWeight\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e24150S2-APS\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6630-815\u003c\/td\u003e\n\u003ctd\u003e1 1\/2\u003c\/td\u003e\n\u003ctd\u003e230V 1Ph 2-Wire\u003c\/td\u003e\n\u003ctd\u003ePressure Switch\u003c\/td\u003e\n\u003ctd\u003eSD1-2HP2PS\u003c\/td\u003e\n\u003ctd\u003e78 ft\u003c\/td\u003e\n\u003ctd\u003e138 ft\u003c\/td\u003e\n\u003ctd\u003e57 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e24150S2-APT\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6630-811\u003c\/td\u003e\n\u003ctd\u003e1 1\/2\u003c\/td\u003e\n\u003ctd\u003e230V 1Ph 2-Wire\u003c\/td\u003e\n\u003ctd\u003eTransducer\u003c\/td\u003e\n\u003ctd\u003eSD1-2HP2\u003c\/td\u003e\n\u003ctd\u003e78 ft\u003c\/td\u003e\n\u003ctd\u003e138 ft\u003c\/td\u003e\n\u003ctd\u003e57 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e24150S3-APS\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6630-825\u003c\/td\u003e\n\u003ctd\u003e1 1\/2\u003c\/td\u003e\n\u003ctd\u003e230V 1Ph 3-Wire\u003c\/td\u003e\n\u003ctd\u003ePressure Switch\u003c\/td\u003e\n\u003ctd\u003eSD1-2HP2PS\u003c\/td\u003e\n\u003ctd\u003e78 ft\u003c\/td\u003e\n\u003ctd\u003e138 ft\u003c\/td\u003e\n\u003ctd\u003e56 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e24150S3-APT\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6630-821\u003c\/td\u003e\n\u003ctd\u003e1 1\/2\u003c\/td\u003e\n\u003ctd\u003e230V 1Ph 3-Wire\u003c\/td\u003e\n\u003ctd\u003eTransducer\u003c\/td\u003e\n\u003ctd\u003eSD1-2HP2\u003c\/td\u003e\n\u003ctd\u003e78 ft\u003c\/td\u003e\n\u003ctd\u003e138 ft\u003c\/td\u003e\n\u003ctd\u003e56 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e24150S3Z-APT\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6630-863\u003c\/td\u003e\n\u003ctd\u003e1 1\/2\u003c\/td\u003e\n\u003ctd\u003e230V 3Ph\u003c\/td\u003e\n\u003ctd\u003eTransducer\u003c\/td\u003e\n\u003ctd\u003eSD3-2HP2\u003c\/td\u003e\n\u003ctd\u003e78 ft\u003c\/td\u003e\n\u003ctd\u003e138 ft\u003c\/td\u003e\n\u003ctd\u003e49 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e24200S3-APS\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6630-833\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e230V 1Ph 3-Wire\u003c\/td\u003e\n\u003ctd\u003ePressure Switch\u003c\/td\u003e\n\u003ctd\u003eSD1-2HP2PS\u003c\/td\u003e\n\u003ctd\u003e110 ft\u003c\/td\u003e\n\u003ctd\u003e194 ft\u003c\/td\u003e\n\u003ctd\u003e58 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e24200S3-APT\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6630-829\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e230V 1Ph 3-Wire\u003c\/td\u003e\n\u003ctd\u003eTransducer\u003c\/td\u003e\n\u003ctd\u003eSD1-2HP2\u003c\/td\u003e\n\u003ctd\u003e110 ft\u003c\/td\u003e\n\u003ctd\u003e194 ft\u003c\/td\u003e\n\u003ctd\u003e58 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e24200S3Z-APT\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6630-837\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e230V 3Ph\u003c\/td\u003e\n\u003ctd\u003eTransducer\u003c\/td\u003e\n\u003ctd\u003eSD3-2HP2\u003c\/td\u003e\n\u003ctd\u003e110 ft\u003c\/td\u003e\n\u003ctd\u003e194 ft\u003c\/td\u003e\n\u003ctd\u003e56 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e24300S3Z-APT\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6630-841\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003ctd\u003e230V 3Ph\u003c\/td\u003e\n\u003ctd\u003eTransducer\u003c\/td\u003e\n\u003ctd\u003eSD3-3HP2\u003c\/td\u003e\n\u003ctd\u003e143 ft\u003c\/td\u003e\n\u003ctd\u003e249 ft\u003c\/td\u003e\n\u003ctd\u003e67 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e24500S3Z-APT\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6630-846\u003c\/td\u003e\n\u003ctd\u003e5\u003c\/td\u003e\n\u003ctd\u003e230V 3Ph\u003c\/td\u003e\n\u003ctd\u003eTransducer\u003c\/td\u003e\n\u003ctd\u003eSD3-5HP2\u003c\/td\u003e\n\u003ctd\u003e250 ft\u003c\/td\u003e\n\u003ctd\u003e420 ft\u003c\/td\u003e\n\u003ctd\u003e85 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"font-size:12.5px;color:#9B9EA3;margin-top:8px;line-height:1.55\"\u003eHead at 55 GPM is read from the published AutoPAC curve (Pumps by Baker catalog (Sept 2025, rev 3\/26), p. 159), digitized, interpolated in a straight line between the digitized points at 50 and 60 GPM, and rounded down. Shut-off head as printed. Drive per the compatibility table on p. 141 (1 1\/2 HP three-phase builds use the SD3-2HP2). Sources: Pumps by Baker catalog (Sept 2025, rev 3\/26), pp. 141-143 and 159; Baker Pumps and Accessories price list, effective 7\/1\/2026.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eShared Specifications\u003c\/div\u003e\n\u003cdiv class=\"gs-lead\"\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eIncluded\u003c\/td\u003e\n\u003ctd\u003ePump end, Baker 4 in motor, AutoDRIVE drive, and pressure switch or transducer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDischarge\u003c\/td\u003e\n\u003ctd\u003e2 in NPT (female)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCheck valve\u003c\/td\u003e\n\u003ctd\u003eBuilt in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply\u003c\/td\u003e\n\u003ctd\u003e230V single-phase, 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor\u003c\/td\u003e\n\u003ctd\u003eBaker 4 in submersible motor, matched to the pump end horsepower\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrive enclosure\u003c\/td\u003e\n\u003ctd\u003eNEMA Type 3R steel, 12.25 x 9.25 x 4.68 in, 13 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrive operating temperature\u003c\/td\u003e\n\u003ctd\u003e-4 to 122°F; SD3-5HP2 rated to 104°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrive efficiency\u003c\/td\u003e\n\u003ctd\u003e95%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePump energy index (PEI)\u003c\/td\u003e\n\u003ctd\u003e0.95\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertification (pump)\u003c\/td\u003e\n\u003ctd\u003eDrinking Water ANSI\/NSF 61\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApp connection\u003c\/td\u003e\n\u003ctd\u003eNone; set up on the drive display\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"font-size:12.5px;color:#9B9EA3;margin-top:8px;line-height:1.55\"\u003eSource: Pumps by Baker catalog (Sept 2025, rev 3\/26), pp. 131-133 and 141-143.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003ePerformance — Will It Do What You Need?\u003c\/div\u003e\n\u003cdiv class=\"gs-lead\"\u003e\n\u003cp\u003e\u003cstrong\u003eTotal head\u003c\/strong\u003e is everything the pump lifts against: the vertical lift from the pumping water level to the discharge, the pressure you set on the drive (2.31 ft for every PSI), and friction in the drop pipe. The drive slows the pump when demand falls, so the curve below is the most the pump delivers at full speed.\u003c\/p\u003e\n\u003cp style=\"margin-bottom:4px\"\u003e\u003cstrong\u003eTotal head in feet, by flow in GPM, at full speed\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eHP (stages)\u003c\/th\u003e\n\u003cth\u003e0\u003c\/th\u003e\n\u003cth\u003e10\u003c\/th\u003e\n\u003cth\u003e20\u003c\/th\u003e\n\u003cth\u003e30\u003c\/th\u003e\n\u003cth\u003e40\u003c\/th\u003e\n\u003cth\u003e50\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003e55*\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e60\u003c\/th\u003e\n\u003cth\u003e70\u003c\/th\u003e\n\u003cth\u003e80\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e1 1\/2 HP (5)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e137\u003c\/td\u003e\n\u003ctd\u003e131\u003c\/td\u003e\n\u003ctd\u003e124\u003c\/td\u003e\n\u003ctd\u003e114\u003c\/td\u003e\n\u003ctd\u003e103\u003c\/td\u003e\n\u003ctd\u003e87\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e78\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e68\u003c\/td\u003e\n\u003ctd\u003e45\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e2 HP (7)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e195\u003c\/td\u003e\n\u003ctd\u003e188\u003c\/td\u003e\n\u003ctd\u003e178\u003c\/td\u003e\n\u003ctd\u003e163\u003c\/td\u003e\n\u003ctd\u003e145\u003c\/td\u003e\n\u003ctd\u003e123\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e110\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e97\u003c\/td\u003e\n\u003ctd\u003e65\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e3 HP (9)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e253\u003c\/td\u003e\n\u003ctd\u003e243\u003c\/td\u003e\n\u003ctd\u003e228\u003c\/td\u003e\n\u003ctd\u003e208\u003c\/td\u003e\n\u003ctd\u003e186\u003c\/td\u003e\n\u003ctd\u003e158\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e143\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e128\u003c\/td\u003e\n\u003ctd\u003e92\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e5 HP (15)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e421\u003c\/td\u003e\n\u003ctd\u003e402\u003c\/td\u003e\n\u003ctd\u003e378\u003c\/td\u003e\n\u003ctd\u003e349\u003c\/td\u003e\n\u003ctd\u003e315\u003c\/td\u003e\n\u003ctd\u003e275\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e250\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e225\u003c\/td\u003e\n\u003ctd\u003e160\u003c\/td\u003e\n\u003ctd\u003e66\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"font-size:12.5px;color:#9B9EA3;margin-top:6px;line-height:1.55\"\u003eDigitized from the published AutoPAC curve in the Pumps by Baker catalog (Sept 2025, rev 3\/26), p. 159, and rounded down. *Rated flow (55 GPM) is interpolated in a straight line between the neighbouring digitized points. Rated flow (55 GPM) in bold. Zero flow is the shut-off point, a ceiling rather than a working point; — marks flows past the end of that curve.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBest operating range:\u003c\/strong\u003e the published curve shades the most efficient operating range; the catalog prints no figures for it. The curve is in the image gallery.\u003c\/p\u003e\n\u003cdiv style=\"display:flex;flex-wrap:wrap;gap:10px;margin:22px 0 4px\"\u003e\n\u003ca href=\"\/pages\/submersible-well-pump-sizing-calculator\" style=\"flex:1 1 200px;text-align:center;display:block;background:#B3122A;color:#ffffff;font-family:Arial Black,Arial,sans-serif;font-size:12px;text-transform:uppercase;letter-spacing:1.2px;padding:11px 18px;text-decoration:none\"\u003eSubmersible Calculator\u003c\/a\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eBefore You Buy — The Limits That Decide the Fit\u003c\/div\u003e\n\u003cdiv class=\"gs-lead\"\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply\u003c\/td\u003e\n\u003ctd\u003e230V single-phase for every build, from a circuit breaker sized per the table below\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure transducer\u003c\/td\u003e\n\u003ctd\u003eMust be installed upright and vertical (manufacturer note)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrive location\u003c\/td\u003e\n\u003ctd\u003eNEMA 3R enclosure, outdoors or indoors; rated to 122°F (104°F for SD3-5HP2); derate above 5500 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor cooling\u003c\/td\u003e\n\u003ctd\u003e1.0 ft\/sec of water flow past the motor at 95°F; motor rated to 95°F water\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWell size\u003c\/td\u003e\n\u003ctd\u003e4 in casing and larger\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePairing\u003c\/td\u003e\n\u003ctd\u003eOne pump and one drive per well\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"margin:14px 0 4px\"\u003e\u003cstrong\u003eBreaker sizing by motor HP (manufacturer recommendation)\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSupply\u003c\/th\u003e\n\u003cth\u003eMotor HP\u003c\/th\u003e\n\u003cth\u003eInput Current\u003c\/th\u003e\n\u003cth\u003eFuse \/ Breaker\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e230V\u003c\/td\u003e\n\u003ctd\u003e1\/2\u003c\/td\u003e\n\u003ctd\u003e6 A\u003c\/td\u003e\n\u003ctd\u003e10 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e230V\u003c\/td\u003e\n\u003ctd\u003e3\/4\u003c\/td\u003e\n\u003ctd\u003e9 A\u003c\/td\u003e\n\u003ctd\u003e15 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e230V\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003ctd\u003e14 A\u003c\/td\u003e\n\u003ctd\u003e20 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e230V\u003c\/td\u003e\n\u003ctd\u003e1 1\/2\u003c\/td\u003e\n\u003ctd\u003e18 A\u003c\/td\u003e\n\u003ctd\u003e25 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e230V\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e28 A\u003c\/td\u003e\n\u003ctd\u003e35 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e230V\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e20 A\u003c\/td\u003e\n\u003ctd\u003e25 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e230V\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003ctd\u003e30 A\u003c\/td\u003e\n\u003ctd\u003e40 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e230V\u003c\/td\u003e\n\u003ctd\u003e5\u003c\/td\u003e\n\u003ctd\u003e42 A\u003c\/td\u003e\n\u003ctd\u003e55 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"font-size:12.5px;color:#9B9EA3;margin-top:8px;line-height:1.55\"\u003eSource: Pumps by Baker catalog (Sept 2025, rev 3\/26), p. 131.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eMaterials of Construction (Pump)\u003c\/div\u003e\n\u003cdiv class=\"gs-lead\"\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eDischarge head\u003c\/td\u003e\n\u003ctd\u003eStainless steel 304, 2 in NPT discharge\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor adapter\u003c\/td\u003e\n\u003ctd\u003eStainless steel 304, NEMA standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCheck valve\u003c\/td\u003e\n\u003ctd\u003eStainless steel 304\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExternal shell\u003c\/td\u003e\n\u003ctd\u003eStainless steel 304, polished\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eImpellers\u003c\/td\u003e\n\u003ctd\u003eNoryl\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiffusers\u003c\/td\u003e\n\u003ctd\u003ePolycarbonate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBearing\u003c\/td\u003e\n\u003ctd\u003ePolyacetal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShaft coupling\u003c\/td\u003e\n\u003ctd\u003eStainless steel 304, NEMA standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStrainer\u003c\/td\u003e\n\u003ctd\u003eStainless steel 304\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShaft\u003c\/td\u003e\n\u003ctd\u003eStainless steel 304\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable guard\u003c\/td\u003e\n\u003ctd\u003eStainless steel 304\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"font-size:12.5px;color:#9B9EA3;margin-top:8px;line-height:1.55\"\u003eSource: Pumps by Baker catalog (Sept 2025, rev 3\/26), pp. 79-80.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eService Parts\u003c\/div\u003e\n\u003cdiv class=\"gs-lead\"\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003ePart\u003c\/th\u003e\n\u003cth\u003ePart No.\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutoDRIVE pressure transducer with 10 ft wire\u003c\/td\u003e\n\u003ctd\u003e6619-028\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutoDRIVE pressure switch with wire\u003c\/td\u003e\n\u003ctd\u003e6619-029\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutoDRIVE keypad\u003c\/td\u003e\n\u003ctd\u003e6619-030\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"font-size:12.5px;color:#9B9EA3;margin-top:8px;line-height:1.55\"\u003eSource: Pumps by Baker catalog (Sept 2025, rev 3\/26), pp. 142-143.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"gs-contact\"\u003eFor engineering-led sizing and selection support or a factory submittal, email \u003ca href=\"mailto:sales@watermainsupply.com\"\u003esales@watermainsupply.com\u003c\/a\u003e or call \u003ca href=\"tel:18885104036\"\u003e1-888.510.4036\u003c\/a\u003e.\u003cbr\u003e© Watermain Supply — A division of E4 Industrial LLC\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch5\u003eData Sheet\u003c\/h5\u003e\n\u003cdiv class=\"gs\"\u003e\n\u003cdiv class=\"gs-dl\"\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0264\/1913\/4527\/files\/AutoPac_Guide.pdf?v=1772502299\" target=\"_blank\" rel=\"noopener\"\u003ePumps by Baker AutoPac Guide\u003c\/a\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch5\u003eVideos\u003c\/h5\u003e\n\u003cdiv class=\"gs\"\u003e\u003cdiv class=\"gs-sec\" style=\"margin-top:6px\"\u003e\n\u003cp style=\"font-size:13px;color:#9B9EA3\"\u003eProduct videos are being added to this listing. For a walkthrough in the meantime, email sales@watermainsupply.com.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003c!-- \/TABS --\u003e","brand":"A.Y. McDonald","offers":[{"title":"1 1\/2 HP - 4 in Motor \/ 230V 1Ph 2-Wire \/ Switch - 24150S2-APS - 78 ft at 55 GPM","offer_id":46602935173295,"sku":"6630-815","price":2982.0,"currency_code":"USD","in_stock":true},{"title":"1 1\/2 HP - 4 in Motor \/ 230V 1Ph 2-Wire \/ Transducer - 24150S2-APT - 78 ft at 55 GPM","offer_id":46602935206063,"sku":"6630-811","price":3161.41,"currency_code":"USD","in_stock":true},{"title":"1 1\/2 HP - 4 in Motor \/ 230V 1Ph 3-Wire \/ Switch - 24150S3-APS - 78 ft at 55 GPM","offer_id":46602935238831,"sku":"6630-825","price":2799.02,"currency_code":"USD","in_stock":true},{"title":"1 1\/2 HP - 4 in Motor \/ 230V 1Ph 3-Wire \/ Transducer - 24150S3-APT - 78 ft at 55 GPM","offer_id":46602935304367,"sku":"6630-821","price":2976.89,"currency_code":"USD","in_stock":true},{"title":"1 1\/2 HP - 4 in Motor \/ 230V 3Ph \/ Transducer - 24150S3Z-APT - 78 ft at 55 GPM","offer_id":46602935369903,"sku":"6630-863","price":3198.68,"currency_code":"USD","in_stock":true},{"title":"2 HP - 4 in Motor \/ 230V 1Ph 3-Wire \/ Switch - 24200S3-APS - 110 ft at 55 GPM","offer_id":46602935271599,"sku":"6630-833","price":3093.43,"currency_code":"USD","in_stock":true},{"title":"2 HP - 4 in Motor \/ 230V 1Ph 3-Wire \/ Transducer - 24200S3-APT - 110 ft at 55 GPM","offer_id":46602935337135,"sku":"6630-829","price":3271.8,"currency_code":"USD","in_stock":true},{"title":"2 HP - 4 in Motor \/ 230V 3Ph \/ Transducer - 24200S3Z-APT - 110 ft at 55 GPM","offer_id":46602935402671,"sku":"6630-837","price":3489.04,"currency_code":"USD","in_stock":true},{"title":"3 HP - 4 in Motor \/ 230V 3Ph \/ Transducer - 24300S3Z-APT - 143 ft at 55 GPM","offer_id":46602935435439,"sku":"6630-841","price":4058.44,"currency_code":"USD","in_stock":true},{"title":"5 HP - 4 in Motor \/ 230V 3Ph \/ Transducer - 24500S3Z-APT - 250 ft at 55 GPM","offer_id":46602935468207,"sku":"6630-846","price":5707.94,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0264\/1913\/4527\/files\/AutoPac_be87381d-8646-4857-b170-9655606ae005.png?v=1772502619"},{"product_id":"baker-autopac-q-60-gpm-24000-series","title":"A.Y. McDonald AutoPAC Q - 60 GPM 24000 Constant Pressure Pump","description":"\u003c!-- TABS --\u003e\n\u003ch5\u003eDescription\u003c\/h5\u003e\n\u003cdiv class=\"gs\"\u003e\n\u003cdiv class=\"gs-head\"\u003e\n\u003cdiv class=\"gs-eyebrow\"\u003eA.Y. McDonald · Constant Pressure Pump System\u003c\/div\u003e\n\u003cdiv class=\"gs-title\"\u003eAutoPAC Q - 60 GPM, 24000 Series High Flow\u003c\/div\u003e\n\u003cdiv class=\"gs-sub\"\u003eBaker stainless steel 4 in submersible pump, motor and AutoDRIVE constant pressure drive, 1 1\/2 to 5 HP, 10 builds.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"gs-badges\"\u003e\n\u003cdiv class=\"gs-badge\" style=\"background:#B3122A;color:#FFFFFF;border-color:#B3122A\"\u003e71-226 ft at 60 GPM\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003e1 1\/2-5 HP\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003e230V Single-Phase Supply\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003eAutoDRIVE Constant Pressure VFD\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003ePressure Switch or Transducer Control\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003e328 ft Max Head (Shut-off)\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003e2 in NPT Discharge\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003eNEMA 3R Drive Enclosure\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003eDrinking Water ANSI\/NSF 61\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003e48-81 lb Weight\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background:#FFFFFF;border:1px solid #C7CBD1;border-top:3px solid #B3122A;padding:12px 16px 12px;margin:16px 0 4px;font-size:13.5px;line-height:1.55;color:#4A4A4F\"\u003e\n\u003cdiv style=\"font-family:Arial Black,Arial,sans-serif;font-size:11px;letter-spacing:1.2px;text-transform:uppercase;color:#B3122A;margin-bottom:8px\"\u003eWhat Ships and What It Needs to Run\u003c\/div\u003e\n\u003cp style=\"margin:0 0 6px\"\u003e\u003cstrong style=\"color:#B3122A\"\u003eIncluded:\u003c\/strong\u003e the pump end and Baker 4 in motor, assembled, with the AutoDRIVE constant pressure drive matched to the motor, and the pressure switch (APS models) or pressure transducer with 10 ft wire (APT models). The drive model for each build is in the Models table.\u003c\/p\u003e\n\u003cp style=\"margin:0 0 6px\"\u003e\u003cstrong style=\"color:#B3122A\"\u003ePower:\u003c\/strong\u003e 230V single-phase supply from a circuit breaker for every build; the three-phase builds take single-phase power and the drive makes three-phase for the motor. Breaker sizes are under Before You Buy.\u003c\/p\u003e\n\u003cp style=\"margin:0\"\u003e\u003cstrong style=\"color:#B3122A\"\u003eSized at install:\u003c\/strong\u003e drop cable, splice kit and the pressure relief valve shown in the manufacturer’s installation diagram.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eOverview\u003c\/div\u003e\n\u003cdiv class=\"gs-lead\"\u003e\n\u003cp\u003eThe AutoPAC is Baker’s constant pressure well package: a 24000 Series High Flow 4 in submersible pump, a Baker motor of the same horsepower, and the AutoDRIVE variable frequency drive. The drive holds a set pressure by changing the pump speed, which allows a smaller pressure tank and a quick, simple installation; setup takes 5 steps or less on the drive’s backlit display.\u003c\/p\u003e\n\u003cp\u003eThis listing is the \u003cstrong\u003eQ - 60 GPM\u003c\/strong\u003e class: 1 1\/2 to 5 HP, with pressure switch and transducer control. The AutoDRIVE is American made and housed in a NEMA 3R steel enclosure rated for outdoor use.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background:#E1E3E6;border-left:3px solid #B8BDC4;padding:8px 14px;font-size:11.5px;color:#4A4A4F;margin-top:14px;line-height:1.5\"\u003eGenuine A.Y. McDonald equipment, factory-new in original packaging — sold and supported by Watermain Supply, an independent industrial supplier. Watermain Supply is an Authorized Stocking A.Y. McDonald and Baker Water Systems Distributor.\u003c\/div\u003e\n\u003cdiv style=\"background:#fff;border-left:5px solid #B3122A;padding:15px 18px;margin-top:12px\"\u003e\n\u003cdiv style=\"font-family:Arial Black,Arial,sans-serif;font-size:15px;color:#B3122A;text-transform:uppercase;letter-spacing:1px;margin-bottom:6px\"\u003eA.Y. McDonald Warranty\u003c\/div\u003e\n\u003cp style=\"margin:0;font-size:13.5px;color:#4A4A4F;line-height:1.55\"\u003ePump and motor: covered for \u003cstrong\u003e3 years from the date of manufacture\u003c\/strong\u003e under A.Y. McDonald’s published terms for Baker submersible motors and assembled submersible pumps with pump ends up to 80 GPM. The AutoDRIVE and pressure control fall under A.Y. McDonald’s standard limited warranty: 2 years from the date of manufacture or 1 year from installation, whichever comes first.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eRoom to Grow\u003c\/div\u003e\n\u003cdiv class=\"gs-lead\"\u003e\n\u003cp\u003eOne pump and one drive per well. Need more head later? Step up in horsepower within the Q - 60 GPM class; the drive model changes with the motor (see the Models table). Need more flow? Move to a higher flow class of the AutoPAC 24000 Series; every class uses the same 2 in NPT discharge.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eModels \u0026amp; Ratings (60 Hz)\u003c\/div\u003e\n\u003cdiv class=\"gs-lead\"\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003cth\u003ePart No.\u003c\/th\u003e\n\u003cth\u003eHP\u003c\/th\u003e\n\u003cth\u003eMotor\u003c\/th\u003e\n\u003cth\u003eControl\u003c\/th\u003e\n\u003cth\u003eAutoDRIVE\u003c\/th\u003e\n\u003cth\u003eHead at 60 GPM\u003c\/th\u003e\n\u003cth\u003eShut-off Head\u003c\/th\u003e\n\u003cth\u003eWeight\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e24150Q2-APS\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6630-816\u003c\/td\u003e\n\u003ctd\u003e1 1\/2\u003c\/td\u003e\n\u003ctd\u003e230V 1Ph 2-Wire\u003c\/td\u003e\n\u003ctd\u003ePressure Switch\u003c\/td\u003e\n\u003ctd\u003eSD1-2HP2PS\u003c\/td\u003e\n\u003ctd\u003e71 ft\u003c\/td\u003e\n\u003ctd\u003e118 ft\u003c\/td\u003e\n\u003ctd\u003e56 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e24150Q2-APT\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6630-812\u003c\/td\u003e\n\u003ctd\u003e1 1\/2\u003c\/td\u003e\n\u003ctd\u003e230V 1Ph 2-Wire\u003c\/td\u003e\n\u003ctd\u003eTransducer\u003c\/td\u003e\n\u003ctd\u003eSD1-2HP2\u003c\/td\u003e\n\u003ctd\u003e71 ft\u003c\/td\u003e\n\u003ctd\u003e118 ft\u003c\/td\u003e\n\u003ctd\u003e56 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e24150Q3-APS\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6630-826\u003c\/td\u003e\n\u003ctd\u003e1 1\/2\u003c\/td\u003e\n\u003ctd\u003e230V 1Ph 3-Wire\u003c\/td\u003e\n\u003ctd\u003ePressure Switch\u003c\/td\u003e\n\u003ctd\u003eSD1-2HP2PS\u003c\/td\u003e\n\u003ctd\u003e71 ft\u003c\/td\u003e\n\u003ctd\u003e118 ft\u003c\/td\u003e\n\u003ctd\u003e55 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e24150Q3-APT\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6630-822\u003c\/td\u003e\n\u003ctd\u003e1 1\/2\u003c\/td\u003e\n\u003ctd\u003e230V 1Ph 3-Wire\u003c\/td\u003e\n\u003ctd\u003eTransducer\u003c\/td\u003e\n\u003ctd\u003eSD1-2HP2\u003c\/td\u003e\n\u003ctd\u003e71 ft\u003c\/td\u003e\n\u003ctd\u003e118 ft\u003c\/td\u003e\n\u003ctd\u003e55 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e24150Q3Z-APT\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6630-864\u003c\/td\u003e\n\u003ctd\u003e1 1\/2\u003c\/td\u003e\n\u003ctd\u003e230V 3Ph\u003c\/td\u003e\n\u003ctd\u003eTransducer\u003c\/td\u003e\n\u003ctd\u003eSD3-2HP2\u003c\/td\u003e\n\u003ctd\u003e71 ft\u003c\/td\u003e\n\u003ctd\u003e118 ft\u003c\/td\u003e\n\u003ctd\u003e48 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e24200Q3-APS\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6630-834\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e230V 1Ph 3-Wire\u003c\/td\u003e\n\u003ctd\u003ePressure Switch\u003c\/td\u003e\n\u003ctd\u003eSD1-2HP2PS\u003c\/td\u003e\n\u003ctd\u003e94 ft\u003c\/td\u003e\n\u003ctd\u003e150 ft\u003c\/td\u003e\n\u003ctd\u003e56 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e24200Q3-APT\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6630-830\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e230V 1Ph 3-Wire\u003c\/td\u003e\n\u003ctd\u003eTransducer\u003c\/td\u003e\n\u003ctd\u003eSD1-2HP2\u003c\/td\u003e\n\u003ctd\u003e94 ft\u003c\/td\u003e\n\u003ctd\u003e150 ft\u003c\/td\u003e\n\u003ctd\u003e56 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e24200Q3Z-APT\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6630-838\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e230V 3Ph\u003c\/td\u003e\n\u003ctd\u003eTransducer\u003c\/td\u003e\n\u003ctd\u003eSD3-2HP2\u003c\/td\u003e\n\u003ctd\u003e94 ft\u003c\/td\u003e\n\u003ctd\u003e150 ft\u003c\/td\u003e\n\u003ctd\u003e54 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e24300Q3Z-APT\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6630-842\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003ctd\u003e230V 3Ph\u003c\/td\u003e\n\u003ctd\u003eTransducer\u003c\/td\u003e\n\u003ctd\u003eSD3-3HP2\u003c\/td\u003e\n\u003ctd\u003e136 ft\u003c\/td\u003e\n\u003ctd\u003e210 ft\u003c\/td\u003e\n\u003ctd\u003e66 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e24500Q3Z-APT\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6630-847\u003c\/td\u003e\n\u003ctd\u003e5\u003c\/td\u003e\n\u003ctd\u003e230V 3Ph\u003c\/td\u003e\n\u003ctd\u003eTransducer\u003c\/td\u003e\n\u003ctd\u003eSD3-5HP2\u003c\/td\u003e\n\u003ctd\u003e226 ft\u003c\/td\u003e\n\u003ctd\u003e328 ft\u003c\/td\u003e\n\u003ctd\u003e81 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"font-size:12.5px;color:#9B9EA3;margin-top:8px;line-height:1.55\"\u003eHead at 60 GPM is read from the published AutoPAC curve (Pumps by Baker catalog (Sept 2025, rev 3\/26), p. 160), digitized and rounded down. Shut-off head as printed. Drive per the compatibility table on p. 141 (1 1\/2 HP three-phase builds use the SD3-2HP2). Sources: Pumps by Baker catalog (Sept 2025, rev 3\/26), pp. 141-143 and 160; Baker Pumps and Accessories price list, effective 7\/1\/2026.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eShared Specifications\u003c\/div\u003e\n\u003cdiv class=\"gs-lead\"\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eIncluded\u003c\/td\u003e\n\u003ctd\u003ePump end, Baker 4 in motor, AutoDRIVE drive, and pressure switch or transducer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDischarge\u003c\/td\u003e\n\u003ctd\u003e2 in NPT (female)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCheck valve\u003c\/td\u003e\n\u003ctd\u003eBuilt in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply\u003c\/td\u003e\n\u003ctd\u003e230V single-phase, 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor\u003c\/td\u003e\n\u003ctd\u003eBaker 4 in submersible motor, matched to the pump end horsepower\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrive enclosure\u003c\/td\u003e\n\u003ctd\u003eNEMA Type 3R steel, 12.25 x 9.25 x 4.68 in, 13 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrive operating temperature\u003c\/td\u003e\n\u003ctd\u003e-4 to 122°F; SD3-5HP2 rated to 104°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrive efficiency\u003c\/td\u003e\n\u003ctd\u003e95%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePump energy index (PEI)\u003c\/td\u003e\n\u003ctd\u003e0.96\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertification (pump)\u003c\/td\u003e\n\u003ctd\u003eDrinking Water ANSI\/NSF 61\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApp connection\u003c\/td\u003e\n\u003ctd\u003eNone; set up on the drive display\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"font-size:12.5px;color:#9B9EA3;margin-top:8px;line-height:1.55\"\u003eSource: Pumps by Baker catalog (Sept 2025, rev 3\/26), pp. 131-133 and 141-143.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003ePerformance — Will It Do What You Need?\u003c\/div\u003e\n\u003cdiv class=\"gs-lead\"\u003e\n\u003cp\u003e\u003cstrong\u003eTotal head\u003c\/strong\u003e is everything the pump lifts against: the vertical lift from the pumping water level to the discharge, the pressure you set on the drive (2.31 ft for every PSI), and friction in the drop pipe. The drive slows the pump when demand falls, so the curve below is the most the pump delivers at full speed.\u003c\/p\u003e\n\u003cp style=\"margin-bottom:4px\"\u003e\u003cstrong\u003eTotal head in feet, by flow in GPM, at full speed\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eHP (stages)\u003c\/th\u003e\n\u003cth\u003e0\u003c\/th\u003e\n\u003cth\u003e10\u003c\/th\u003e\n\u003cth\u003e20\u003c\/th\u003e\n\u003cth\u003e30\u003c\/th\u003e\n\u003cth\u003e40\u003c\/th\u003e\n\u003cth\u003e50\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003e60\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e70\u003c\/th\u003e\n\u003cth\u003e80\u003c\/th\u003e\n\u003cth\u003e90\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e1 1\/2 HP (4)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e117\u003c\/td\u003e\n\u003ctd\u003e113\u003c\/td\u003e\n\u003ctd\u003e109\u003c\/td\u003e\n\u003ctd\u003e103\u003c\/td\u003e\n\u003ctd\u003e95\u003c\/td\u003e\n\u003ctd\u003e84\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e71\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e56\u003c\/td\u003e\n\u003ctd\u003e40\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e2 HP (5)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e149\u003c\/td\u003e\n\u003ctd\u003e144\u003c\/td\u003e\n\u003ctd\u003e137\u003c\/td\u003e\n\u003ctd\u003e129\u003c\/td\u003e\n\u003ctd\u003e119\u003c\/td\u003e\n\u003ctd\u003e108\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e94\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e77\u003c\/td\u003e\n\u003ctd\u003e56\u003c\/td\u003e\n\u003ctd\u003e29\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e3 HP (7)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e209\u003c\/td\u003e\n\u003ctd\u003e204\u003c\/td\u003e\n\u003ctd\u003e196\u003c\/td\u003e\n\u003ctd\u003e185\u003c\/td\u003e\n\u003ctd\u003e172\u003c\/td\u003e\n\u003ctd\u003e155\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e136\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e113\u003c\/td\u003e\n\u003ctd\u003e85\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e5 HP (11)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e330\u003c\/td\u003e\n\u003ctd\u003e319\u003c\/td\u003e\n\u003ctd\u003e307\u003c\/td\u003e\n\u003ctd\u003e292\u003c\/td\u003e\n\u003ctd\u003e273\u003c\/td\u003e\n\u003ctd\u003e251\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e226\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e193\u003c\/td\u003e\n\u003ctd\u003e150\u003c\/td\u003e\n\u003ctd\u003e78\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"font-size:12.5px;color:#9B9EA3;margin-top:6px;line-height:1.55\"\u003eDigitized from the published AutoPAC curve in the Pumps by Baker catalog (Sept 2025, rev 3\/26), p. 160, and rounded down. Rated flow (60 GPM) in bold. Zero flow is the shut-off point, a ceiling rather than a working point; — marks flows past the end of that curve.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBest operating range:\u003c\/strong\u003e the published curve shades the most efficient operating range; the catalog prints no figures for it. The curve is in the image gallery.\u003c\/p\u003e\n\u003cdiv style=\"display:flex;flex-wrap:wrap;gap:10px;margin:22px 0 4px\"\u003e\n\u003ca href=\"\/pages\/submersible-well-pump-sizing-calculator\" style=\"flex:1 1 200px;text-align:center;display:block;background:#B3122A;color:#ffffff;font-family:Arial Black,Arial,sans-serif;font-size:12px;text-transform:uppercase;letter-spacing:1.2px;padding:11px 18px;text-decoration:none\"\u003eSubmersible Calculator\u003c\/a\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eBefore You Buy — The Limits That Decide the Fit\u003c\/div\u003e\n\u003cdiv class=\"gs-lead\"\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply\u003c\/td\u003e\n\u003ctd\u003e230V single-phase for every build, from a circuit breaker sized per the table below\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure transducer\u003c\/td\u003e\n\u003ctd\u003eMust be installed upright and vertical (manufacturer note)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrive location\u003c\/td\u003e\n\u003ctd\u003eNEMA 3R enclosure, outdoors or indoors; rated to 122°F (104°F for SD3-5HP2); derate above 5500 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor cooling\u003c\/td\u003e\n\u003ctd\u003e1.0 ft\/sec of water flow past the motor at 95°F; motor rated to 95°F water\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWell size\u003c\/td\u003e\n\u003ctd\u003e4 in casing and larger\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePairing\u003c\/td\u003e\n\u003ctd\u003eOne pump and one drive per well\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"margin:14px 0 4px\"\u003e\u003cstrong\u003eBreaker sizing by motor HP (manufacturer recommendation)\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSupply\u003c\/th\u003e\n\u003cth\u003eMotor HP\u003c\/th\u003e\n\u003cth\u003eInput Current\u003c\/th\u003e\n\u003cth\u003eFuse \/ Breaker\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e230V\u003c\/td\u003e\n\u003ctd\u003e1\/2\u003c\/td\u003e\n\u003ctd\u003e6 A\u003c\/td\u003e\n\u003ctd\u003e10 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e230V\u003c\/td\u003e\n\u003ctd\u003e3\/4\u003c\/td\u003e\n\u003ctd\u003e9 A\u003c\/td\u003e\n\u003ctd\u003e15 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e230V\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003ctd\u003e14 A\u003c\/td\u003e\n\u003ctd\u003e20 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e230V\u003c\/td\u003e\n\u003ctd\u003e1 1\/2\u003c\/td\u003e\n\u003ctd\u003e18 A\u003c\/td\u003e\n\u003ctd\u003e25 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e230V\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e28 A\u003c\/td\u003e\n\u003ctd\u003e35 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e230V\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e20 A\u003c\/td\u003e\n\u003ctd\u003e25 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e230V\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003ctd\u003e30 A\u003c\/td\u003e\n\u003ctd\u003e40 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e230V\u003c\/td\u003e\n\u003ctd\u003e5\u003c\/td\u003e\n\u003ctd\u003e42 A\u003c\/td\u003e\n\u003ctd\u003e55 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"font-size:12.5px;color:#9B9EA3;margin-top:8px;line-height:1.55\"\u003eSource: Pumps by Baker catalog (Sept 2025, rev 3\/26), p. 131.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eMaterials of Construction (Pump)\u003c\/div\u003e\n\u003cdiv class=\"gs-lead\"\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eDischarge head\u003c\/td\u003e\n\u003ctd\u003eStainless steel 304, 2 in NPT discharge\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor adapter\u003c\/td\u003e\n\u003ctd\u003eStainless steel 304, NEMA standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCheck valve\u003c\/td\u003e\n\u003ctd\u003eStainless steel 304\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExternal shell\u003c\/td\u003e\n\u003ctd\u003eStainless steel 304, polished\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eImpellers\u003c\/td\u003e\n\u003ctd\u003eNoryl\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiffusers\u003c\/td\u003e\n\u003ctd\u003ePolycarbonate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBearing\u003c\/td\u003e\n\u003ctd\u003ePolyacetal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShaft coupling\u003c\/td\u003e\n\u003ctd\u003eStainless steel 304, NEMA standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStrainer\u003c\/td\u003e\n\u003ctd\u003eStainless steel 304\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShaft\u003c\/td\u003e\n\u003ctd\u003eStainless steel 304\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable guard\u003c\/td\u003e\n\u003ctd\u003eStainless steel 304\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"font-size:12.5px;color:#9B9EA3;margin-top:8px;line-height:1.55\"\u003eSource: Pumps by Baker catalog (Sept 2025, rev 3\/26), pp. 79-80.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eService Parts\u003c\/div\u003e\n\u003cdiv class=\"gs-lead\"\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003ePart\u003c\/th\u003e\n\u003cth\u003ePart No.\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutoDRIVE pressure transducer with 10 ft wire\u003c\/td\u003e\n\u003ctd\u003e6619-028\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutoDRIVE pressure switch with wire\u003c\/td\u003e\n\u003ctd\u003e6619-029\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutoDRIVE keypad\u003c\/td\u003e\n\u003ctd\u003e6619-030\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"font-size:12.5px;color:#9B9EA3;margin-top:8px;line-height:1.55\"\u003eSource: Pumps by Baker catalog (Sept 2025, rev 3\/26), pp. 142-143.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"gs-contact\"\u003eFor engineering-led sizing and selection support or a factory submittal, email \u003ca href=\"mailto:sales@watermainsupply.com\"\u003esales@watermainsupply.com\u003c\/a\u003e or call \u003ca href=\"tel:18885104036\"\u003e1-888.510.4036\u003c\/a\u003e.\u003cbr\u003e© Watermain Supply — A division of E4 Industrial LLC\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch5\u003eData Sheet\u003c\/h5\u003e\n\u003cdiv class=\"gs\"\u003e\n\u003cdiv class=\"gs-dl\"\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0264\/1913\/4527\/files\/AutoPac_Guide.pdf?v=1772502299\" target=\"_blank\" rel=\"noopener\"\u003ePumps by Baker AutoPac Guide\u003c\/a\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch5\u003eVideos\u003c\/h5\u003e\n\u003cdiv class=\"gs\"\u003e\u003cdiv class=\"gs-sec\" style=\"margin-top:6px\"\u003e\n\u003cp style=\"font-size:13px;color:#9B9EA3\"\u003eProduct videos are being added to this listing. For a walkthrough in the meantime, email sales@watermainsupply.com.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003c!-- \/TABS --\u003e","brand":"A.Y. McDonald","offers":[{"title":"1 1\/2 HP - 4 in Motor \/ 230V 1Ph 2-Wire \/ Switch - 24150Q2-APS - 71 ft at 60 GPM","offer_id":46602935500975,"sku":"6630-816","price":2793.91,"currency_code":"USD","in_stock":true},{"title":"1 1\/2 HP - 4 in Motor \/ 230V 1Ph 2-Wire \/ Transducer - 24150Q2-APT - 71 ft at 60 GPM","offer_id":46602935533743,"sku":"6630-812","price":2972.8,"currency_code":"USD","in_stock":true},{"title":"1 1\/2 HP - 4 in Motor \/ 230V 1Ph 3-Wire \/ Switch - 24150Q3-APS - 71 ft at 60 GPM","offer_id":46602935566511,"sku":"6630-826","price":2610.41,"currency_code":"USD","in_stock":true},{"title":"1 1\/2 HP - 4 in Motor \/ 230V 1Ph 3-Wire \/ Transducer - 24150Q3-APT - 71 ft at 60 GPM","offer_id":46602935632047,"sku":"6630-822","price":2789.31,"currency_code":"USD","in_stock":true},{"title":"1 1\/2 HP - 4 in Motor \/ 230V 3Ph \/ Transducer - 24150Q3Z-APT - 71 ft at 60 GPM","offer_id":46602935697583,"sku":"6630-864","price":3010.59,"currency_code":"USD","in_stock":true},{"title":"2 HP - 4 in Motor \/ 230V 1Ph 3-Wire \/ Switch - 24200Q3-APS - 94 ft at 60 GPM","offer_id":46602935599279,"sku":"6630-834","price":2766.3,"currency_code":"USD","in_stock":true},{"title":"2 HP - 4 in Motor \/ 230V 1Ph 3-Wire \/ Transducer - 24200Q3-APT - 94 ft at 60 GPM","offer_id":46602935664815,"sku":"6630-830","price":2945.71,"currency_code":"USD","in_stock":true},{"title":"2 HP - 4 in Motor \/ 230V 3Ph \/ Transducer - 24200Q3Z-APT - 94 ft at 60 GPM","offer_id":46602935730351,"sku":"6630-838","price":3162.95,"currency_code":"USD","in_stock":true},{"title":"3 HP - 4 in Motor \/ 230V 3Ph \/ Transducer - 24300Q3Z-APT - 136 ft at 60 GPM","offer_id":46602935763119,"sku":"6630-842","price":3964.9,"currency_code":"USD","in_stock":true},{"title":"5 HP - 4 in Motor \/ 230V 3Ph \/ Transducer - 24500Q3Z-APT - 226 ft at 60 GPM","offer_id":46602935795887,"sku":"6630-847","price":5572.5,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0264\/1913\/4527\/files\/AutoPac_dc966b58-6f1b-4552-bdb2-1596972df843.png?v=1772502621"},{"product_id":"baker-autopac-t-80-gpm-24000-series","title":"A.Y. McDonald AutoPAC T - 80 GPM 24000 Constant Pressure Pump","description":"\u003c!-- TABS --\u003e\n\u003ch5\u003eDescription\u003c\/h5\u003e\n\u003cdiv class=\"gs\"\u003e\n\u003cdiv class=\"gs-head\"\u003e\n\u003cdiv class=\"gs-eyebrow\"\u003eA.Y. McDonald · Constant Pressure Pump System\u003c\/div\u003e\n\u003cdiv class=\"gs-title\"\u003eAutoPAC T - 80 GPM, 24000 Series High Flow\u003c\/div\u003e\n\u003cdiv class=\"gs-sub\"\u003eBaker stainless steel 4 in submersible pump, motor and AutoDRIVE constant pressure drive, 3 to 5 HP, 2 builds.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"gs-badges\"\u003e\n\u003cdiv class=\"gs-badge\" style=\"background:#B3122A;color:#FFFFFF;border-color:#B3122A\"\u003e93-178 ft at 80 GPM\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003e3-5 HP\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003e230V Single-Phase Supply\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003eAutoDRIVE Constant Pressure VFD\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003eTransducer Control\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003e263 ft Max Head (Shut-off)\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003e2 in NPT Discharge\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003eNEMA 3R Drive Enclosure\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003eDrinking Water ANSI\/NSF 61\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003e64-80 lb Weight\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background:#FFFFFF;border:1px solid #C7CBD1;border-top:3px solid #B3122A;padding:12px 16px 12px;margin:16px 0 4px;font-size:13.5px;line-height:1.55;color:#4A4A4F\"\u003e\n\u003cdiv style=\"font-family:Arial Black,Arial,sans-serif;font-size:11px;letter-spacing:1.2px;text-transform:uppercase;color:#B3122A;margin-bottom:8px\"\u003eWhat Ships and What It Needs to Run\u003c\/div\u003e\n\u003cp style=\"margin:0 0 6px\"\u003e\u003cstrong style=\"color:#B3122A\"\u003eIncluded:\u003c\/strong\u003e the pump end and Baker 4 in motor, assembled, with the AutoDRIVE constant pressure drive matched to the motor, and the pressure switch (APS models) or pressure transducer with 10 ft wire (APT models). The drive model for each build is in the Models table.\u003c\/p\u003e\n\u003cp style=\"margin:0 0 6px\"\u003e\u003cstrong style=\"color:#B3122A\"\u003ePower:\u003c\/strong\u003e 230V single-phase supply from a circuit breaker for every build; the three-phase builds take single-phase power and the drive makes three-phase for the motor. Breaker sizes are under Before You Buy.\u003c\/p\u003e\n\u003cp style=\"margin:0\"\u003e\u003cstrong style=\"color:#B3122A\"\u003eSized at install:\u003c\/strong\u003e drop cable, splice kit and the pressure relief valve shown in the manufacturer’s installation diagram.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eOverview\u003c\/div\u003e\n\u003cdiv class=\"gs-lead\"\u003e\n\u003cp\u003eThe AutoPAC is Baker’s constant pressure well package: a 24000 Series High Flow 4 in submersible pump, a Baker motor of the same horsepower, and the AutoDRIVE variable frequency drive. The drive holds a set pressure by changing the pump speed, which allows a smaller pressure tank and a quick, simple installation; setup takes 5 steps or less on the drive’s backlit display.\u003c\/p\u003e\n\u003cp\u003eThis listing is the \u003cstrong\u003eT - 80 GPM\u003c\/strong\u003e class: 3 to 5 HP, with transducer control. The AutoDRIVE is American made and housed in a NEMA 3R steel enclosure rated for outdoor use.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background:#E1E3E6;border-left:3px solid #B8BDC4;padding:8px 14px;font-size:11.5px;color:#4A4A4F;margin-top:14px;line-height:1.5\"\u003eGenuine A.Y. McDonald equipment, factory-new in original packaging — sold and supported by Watermain Supply, an independent industrial supplier. Watermain Supply is an Authorized Stocking A.Y. McDonald and Baker Water Systems Distributor.\u003c\/div\u003e\n\u003cdiv style=\"background:#fff;border-left:5px solid #B3122A;padding:15px 18px;margin-top:12px\"\u003e\n\u003cdiv style=\"font-family:Arial Black,Arial,sans-serif;font-size:15px;color:#B3122A;text-transform:uppercase;letter-spacing:1px;margin-bottom:6px\"\u003eA.Y. McDonald Warranty\u003c\/div\u003e\n\u003cp style=\"margin:0;font-size:13.5px;color:#4A4A4F;line-height:1.55\"\u003ePump and motor: covered for \u003cstrong\u003e3 years from the date of manufacture\u003c\/strong\u003e under A.Y. McDonald’s published terms for Baker submersible motors and assembled submersible pumps with pump ends up to 80 GPM. The AutoDRIVE and pressure control fall under A.Y. McDonald’s standard limited warranty: 2 years from the date of manufacture or 1 year from installation, whichever comes first.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eRoom to Grow\u003c\/div\u003e\n\u003cdiv class=\"gs-lead\"\u003e\n\u003cp\u003eOne pump and one drive per well. Need more head later? Step up in horsepower within the T - 80 GPM class; the drive model changes with the motor (see the Models table). Need more flow? Move to a higher flow class of the AutoPAC 24000 Series; every class uses the same 2 in NPT discharge.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eModels \u0026amp; Ratings (60 Hz)\u003c\/div\u003e\n\u003cdiv class=\"gs-lead\"\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003cth\u003ePart No.\u003c\/th\u003e\n\u003cth\u003eHP\u003c\/th\u003e\n\u003cth\u003eMotor\u003c\/th\u003e\n\u003cth\u003eControl\u003c\/th\u003e\n\u003cth\u003eAutoDRIVE\u003c\/th\u003e\n\u003cth\u003eHead at 80 GPM\u003c\/th\u003e\n\u003cth\u003eShut-off Head\u003c\/th\u003e\n\u003cth\u003eWeight\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e24300T3Z-APT\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6630-843\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003ctd\u003e230V 3Ph\u003c\/td\u003e\n\u003ctd\u003eTransducer\u003c\/td\u003e\n\u003ctd\u003eSD3-3HP2\u003c\/td\u003e\n\u003ctd\u003e93 ft\u003c\/td\u003e\n\u003ctd\u003e143 ft\u003c\/td\u003e\n\u003ctd\u003e64 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e24500T3Z-APT\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6630-848\u003c\/td\u003e\n\u003ctd\u003e5\u003c\/td\u003e\n\u003ctd\u003e230V 3Ph\u003c\/td\u003e\n\u003ctd\u003eTransducer\u003c\/td\u003e\n\u003ctd\u003eSD3-5HP2\u003c\/td\u003e\n\u003ctd\u003e178 ft\u003c\/td\u003e\n\u003ctd\u003e263 ft\u003c\/td\u003e\n\u003ctd\u003e80 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"font-size:12.5px;color:#9B9EA3;margin-top:8px;line-height:1.55\"\u003eHead at 80 GPM is read from the published AutoPAC curve (Pumps by Baker catalog (Sept 2025, rev 3\/26), p. 161), digitized, interpolated in a straight line between the digitized points at 75 and 87.5 GPM, and rounded down. Shut-off head as printed. Drive per the compatibility table on p. 141 (1 1\/2 HP three-phase builds use the SD3-2HP2). Sources: Pumps by Baker catalog (Sept 2025, rev 3\/26), pp. 141-143 and 161; Baker Pumps and Accessories price list, effective 7\/1\/2026.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eShared Specifications\u003c\/div\u003e\n\u003cdiv class=\"gs-lead\"\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eIncluded\u003c\/td\u003e\n\u003ctd\u003ePump end, Baker 4 in motor, AutoDRIVE drive, and pressure switch or transducer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDischarge\u003c\/td\u003e\n\u003ctd\u003e2 in NPT (female)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCheck valve\u003c\/td\u003e\n\u003ctd\u003eBuilt in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply\u003c\/td\u003e\n\u003ctd\u003e230V single-phase, 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor\u003c\/td\u003e\n\u003ctd\u003eBaker 4 in submersible motor, matched to the pump end horsepower\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrive enclosure\u003c\/td\u003e\n\u003ctd\u003eNEMA Type 3R steel, 12.25 x 9.25 x 4.68 in, 13 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrive operating temperature\u003c\/td\u003e\n\u003ctd\u003e-4 to 122°F; SD3-5HP2 rated to 104°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrive efficiency\u003c\/td\u003e\n\u003ctd\u003e95%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePump energy index (PEI)\u003c\/td\u003e\n\u003ctd\u003e1.00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertification (pump)\u003c\/td\u003e\n\u003ctd\u003eDrinking Water ANSI\/NSF 61\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApp connection\u003c\/td\u003e\n\u003ctd\u003eNone; set up on the drive display\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"font-size:12.5px;color:#9B9EA3;margin-top:8px;line-height:1.55\"\u003eSource: Pumps by Baker catalog (Sept 2025, rev 3\/26), pp. 131-133 and 141-143.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003ePerformance — Will It Do What You Need?\u003c\/div\u003e\n\u003cdiv class=\"gs-lead\"\u003e\n\u003cp\u003e\u003cstrong\u003eTotal head\u003c\/strong\u003e is everything the pump lifts against: the vertical lift from the pumping water level to the discharge, the pressure you set on the drive (2.31 ft for every PSI), and friction in the drop pipe. The drive slows the pump when demand falls, so the curve below is the most the pump delivers at full speed.\u003c\/p\u003e\n\u003cp style=\"margin-bottom:4px\"\u003e\u003cstrong\u003eTotal head in feet, by flow in GPM, at full speed\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eHP (stages)\u003c\/th\u003e\n\u003cth\u003e0\u003c\/th\u003e\n\u003cth\u003e12.5\u003c\/th\u003e\n\u003cth\u003e25\u003c\/th\u003e\n\u003cth\u003e37.5\u003c\/th\u003e\n\u003cth\u003e50\u003c\/th\u003e\n\u003cth\u003e62.5\u003c\/th\u003e\n\u003cth\u003e75\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003e80*\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e87.5\u003c\/th\u003e\n\u003cth\u003e100\u003c\/th\u003e\n\u003cth\u003e112.5\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e3 HP (5)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e146\u003c\/td\u003e\n\u003ctd\u003e138\u003c\/td\u003e\n\u003ctd\u003e130\u003c\/td\u003e\n\u003ctd\u003e122\u003c\/td\u003e\n\u003ctd\u003e114\u003c\/td\u003e\n\u003ctd\u003e105\u003c\/td\u003e\n\u003ctd\u003e97\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e93\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e88\u003c\/td\u003e\n\u003ctd\u003e77\u003c\/td\u003e\n\u003ctd\u003e66\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e5 HP (9)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e265\u003c\/td\u003e\n\u003ctd\u003e259\u003c\/td\u003e\n\u003ctd\u003e252\u003c\/td\u003e\n\u003ctd\u003e242\u003c\/td\u003e\n\u003ctd\u003e225\u003c\/td\u003e\n\u003ctd\u003e207\u003c\/td\u003e\n\u003ctd\u003e187\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e178\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e164\u003c\/td\u003e\n\u003ctd\u003e139\u003c\/td\u003e\n\u003ctd\u003e114\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"font-size:12.5px;color:#9B9EA3;margin-top:6px;line-height:1.55\"\u003eDigitized from the published AutoPAC curve in the Pumps by Baker catalog (Sept 2025, rev 3\/26), p. 161, and rounded down. *Rated flow (80 GPM) is interpolated in a straight line between the neighbouring digitized points. Rated flow (80 GPM) in bold. Zero flow is the shut-off point, a ceiling rather than a working point; — marks flows past the end of that curve.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBest operating range:\u003c\/strong\u003e the published curve shades the most efficient operating range; the catalog prints no figures for it. The curve is in the image gallery.\u003c\/p\u003e\n\u003cdiv style=\"display:flex;flex-wrap:wrap;gap:10px;margin:22px 0 4px\"\u003e\n\u003ca href=\"\/pages\/submersible-well-pump-sizing-calculator\" style=\"flex:1 1 200px;text-align:center;display:block;background:#B3122A;color:#ffffff;font-family:Arial Black,Arial,sans-serif;font-size:12px;text-transform:uppercase;letter-spacing:1.2px;padding:11px 18px;text-decoration:none\"\u003eSubmersible Calculator\u003c\/a\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eBefore You Buy — The Limits That Decide the Fit\u003c\/div\u003e\n\u003cdiv class=\"gs-lead\"\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply\u003c\/td\u003e\n\u003ctd\u003e230V single-phase for every build, from a circuit breaker sized per the table below\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure transducer\u003c\/td\u003e\n\u003ctd\u003eMust be installed upright and vertical (manufacturer note)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrive location\u003c\/td\u003e\n\u003ctd\u003eNEMA 3R enclosure, outdoors or indoors; rated to 122°F (104°F for SD3-5HP2); derate above 5500 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor cooling\u003c\/td\u003e\n\u003ctd\u003e1.0 ft\/sec of water flow past the motor at 95°F; motor rated to 95°F water\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWell size\u003c\/td\u003e\n\u003ctd\u003e4 in casing and larger\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePairing\u003c\/td\u003e\n\u003ctd\u003eOne pump and one drive per well\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"margin:14px 0 4px\"\u003e\u003cstrong\u003eBreaker sizing by motor HP (manufacturer recommendation)\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSupply\u003c\/th\u003e\n\u003cth\u003eMotor HP\u003c\/th\u003e\n\u003cth\u003eInput Current\u003c\/th\u003e\n\u003cth\u003eFuse \/ Breaker\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e230V\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e20 A\u003c\/td\u003e\n\u003ctd\u003e25 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e230V\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003ctd\u003e30 A\u003c\/td\u003e\n\u003ctd\u003e40 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e230V\u003c\/td\u003e\n\u003ctd\u003e5\u003c\/td\u003e\n\u003ctd\u003e42 A\u003c\/td\u003e\n\u003ctd\u003e55 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"font-size:12.5px;color:#9B9EA3;margin-top:8px;line-height:1.55\"\u003eSource: Pumps by Baker catalog (Sept 2025, rev 3\/26), p. 131.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eMaterials of Construction (Pump)\u003c\/div\u003e\n\u003cdiv class=\"gs-lead\"\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eDischarge head\u003c\/td\u003e\n\u003ctd\u003eStainless steel 304, 2 in NPT discharge\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor adapter\u003c\/td\u003e\n\u003ctd\u003eStainless steel 304, NEMA standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCheck valve\u003c\/td\u003e\n\u003ctd\u003eStainless steel 304\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExternal shell\u003c\/td\u003e\n\u003ctd\u003eStainless steel 304, polished\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eImpellers\u003c\/td\u003e\n\u003ctd\u003eNoryl\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiffusers\u003c\/td\u003e\n\u003ctd\u003ePolycarbonate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBearing\u003c\/td\u003e\n\u003ctd\u003ePolyacetal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShaft coupling\u003c\/td\u003e\n\u003ctd\u003eStainless steel 304, NEMA standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStrainer\u003c\/td\u003e\n\u003ctd\u003eStainless steel 304\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShaft\u003c\/td\u003e\n\u003ctd\u003eStainless steel 304\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable guard\u003c\/td\u003e\n\u003ctd\u003eStainless steel 304\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"font-size:12.5px;color:#9B9EA3;margin-top:8px;line-height:1.55\"\u003eSource: Pumps by Baker catalog (Sept 2025, rev 3\/26), pp. 79-80.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eService Parts\u003c\/div\u003e\n\u003cdiv class=\"gs-lead\"\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003ePart\u003c\/th\u003e\n\u003cth\u003ePart No.\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutoDRIVE pressure transducer with 10 ft wire\u003c\/td\u003e\n\u003ctd\u003e6619-028\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutoDRIVE pressure switch with wire\u003c\/td\u003e\n\u003ctd\u003e6619-029\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutoDRIVE keypad\u003c\/td\u003e\n\u003ctd\u003e6619-030\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"font-size:12.5px;color:#9B9EA3;margin-top:8px;line-height:1.55\"\u003eSource: Pumps by Baker catalog (Sept 2025, rev 3\/26), pp. 142-143.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"gs-contact\"\u003eFor engineering-led sizing and selection support or a factory submittal, email \u003ca href=\"mailto:sales@watermainsupply.com\"\u003esales@watermainsupply.com\u003c\/a\u003e or call \u003ca href=\"tel:18885104036\"\u003e1-888.510.4036\u003c\/a\u003e.\u003cbr\u003e© Watermain Supply — A division of E4 Industrial LLC\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch5\u003eData Sheet\u003c\/h5\u003e\n\u003cdiv class=\"gs\"\u003e\n\u003cdiv class=\"gs-dl\"\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0264\/1913\/4527\/files\/AutoPac_Guide.pdf?v=1772502299\" target=\"_blank\" rel=\"noopener\"\u003ePumps by Baker AutoPac Guide\u003c\/a\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch5\u003eVideos\u003c\/h5\u003e\n\u003cdiv class=\"gs\"\u003e\u003cdiv class=\"gs-sec\" style=\"margin-top:6px\"\u003e\n\u003cp style=\"font-size:13px;color:#9B9EA3\"\u003eProduct videos are being added to this listing. For a walkthrough in the meantime, email sales@watermainsupply.com.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003c!-- \/TABS --\u003e","brand":"A.Y. McDonald","offers":[{"title":"3 HP - 4 in Motor \/ 230V 3Ph \/ Transducer - 24300T3Z-APT - 93 ft at 80 GPM","offer_id":46602935828655,"sku":"6630-843","price":3905.1,"currency_code":"USD","in_stock":true},{"title":"5 HP - 4 in Motor \/ 230V 3Ph \/ Transducer - 24500T3Z-APT - 178 ft at 80 GPM","offer_id":46602935861423,"sku":"6630-848","price":5537.23,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0264\/1913\/4527\/files\/AutoPac_6087be45-8f65-4249-b462-e5aa81b8b671.png?v=1772502622"},{"product_id":"grundfos-5-sqe-submersible-well-pump","title":"Grundfos 5 SQE Submersible Well Pump","description":"\u003c!-- TABS --\u003e\n\u003ch5\u003eDescription\u003c\/h5\u003e\n\u003cdiv class=\"gs\"\u003e\n\n\u003cdiv class=\"gs-head\"\u003e\n\u003cdiv class=\"gs-eyebrow\"\u003eGrundfos · 3 in Submersible Well Pump\u003c\/div\u003e\n\u003cdiv class=\"gs-title\"\u003e5 SQE\u003c\/div\u003e\n\u003cdiv class=\"gs-sub\"\u003eNominal 5 GPM 3 in constant-pressure submersible well pump with a permanent-magnet motor and built-in protection: 9 models from 1\/2 to 1-1\/2 HP, 86-450 ft of head at 5 GPM, 1 in NPT discharge. Runs on a CU 302 for constant pressure.\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"gs-badges\"\u003e\n\u003cdiv class=\"gs-badge\" style=\"background:#B3122A;color:#FFFFFF;border-color:#B3122A\"\u003e5 GPM Rated Flow\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003e1\/2 to 1-1\/2 HP\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003e86-450 ft at 5 GPM\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003e1.5-8 GPM Flow Range\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003eConstant Pressure with CU 302\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003e3 in Min. Well\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003e1 in NPT Discharge\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003e115V or 230V 1Ph\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003eDry-Run, Voltage and Overload Protection\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003e2.9 in Dia x 29.1-38.0 in L\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003e11-16 lb Ship Weight\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eOverview\u003c\/div\u003e\n\u003cdiv class=\"gs-lead\"\u003e\n\u003cp\u003eThe Grundfos 5 SQE is a 3 in stainless steel well pump with a variable-speed permanent-magnet \"Smart Motor\". Paired with a \u003ca href=\"\/products\/grundfos-cu-302-constant-pressure-control\"\u003eGrundfos CU 302 Constant Pressure Control\u003c\/a\u003e, it holds the pressure you set, from a trickle at one tap to full flow, instead of cycling between a pressure switch's cut-in and cut-out. The CU 302 talks to the pump over the power leads, so no extra wires go down the well, and it pairs with the Grundfos GO and HOME apps by Bluetooth.\u003c\/p\u003e\n\u003cp\u003eIt is rated at 5 GPM, with 9 models from 1\/2 to 1-1\/2 HP for deeper settings. The pump fits a 3 in or larger well and suits household supply, light commercial service, irrigation and tank filling or emptying.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eConstant pressure.\u003c\/strong\u003e The CU 302 changes pump speed, 3,000 to 10,700 rpm, to hold its setpoint (factory 50 PSI, adjustable 20 to 100 PSI in 5 PSI steps). It works with a 2 gal diaphragm tank instead of a large pressure tank.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBuilt-in protection.\u003c\/strong\u003e Dry-run, over- and undervoltage (cuts out below 150 V and above 315 V and restarts by itself), overload, locked-rotor and over-temperature protection are built into the motor. No protection relay or motor starter needed.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSoft start, no start limit.\u003c\/strong\u003e The motor ramps up in about 3 seconds and has no limit on starts or stops per hour.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSand-tolerant hydraulics.\u003c\/strong\u003e Floating impellers each run on their own tungsten carbide \/ ceramic bearing; a top bearing protects pump and motor against upthrust at start-up.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall it any way up.\u003c\/strong\u003e Vertical, horizontal or anywhere between, with a built-in spring check valve; use a flow sleeve when horizontal.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"background:#FFFFFF;border:1px solid #C7CBD1;border-top:3px solid #B3122A;padding:12px 16px 12px;margin:16px 0 4px;font-size:13.5px;line-height:1.55;color:#4A4A4F\"\u003e\n\u003cdiv style=\"font-family:Arial Black,Arial,sans-serif;font-size:11px;letter-spacing:1.2px;text-transform:uppercase;color:#B3122A;margin-bottom:8px\"\u003eWhat Ships and What It Needs to Run\u003c\/div\u003e\n\u003cp style=\"margin:0 0 6px\"\u003e\u003cstrong style=\"color:#B3122A\"\u003eIncluded:\u003c\/strong\u003e the pump and its 3 in SQE motor, assembled, with a built-in check valve, plus a 5 ft, 14 AWG motor cable with plug that you press onto the motor socket and secure with four screws. The controller is \u003cstrong\u003enot\u003c\/strong\u003e in the box.\u003c\/p\u003e\n\u003cp style=\"margin:0 0 6px\"\u003e\u003cstrong style=\"color:#B3122A\"\u003eFor constant pressure: CU 302 and a pressure sensor, ordered separately.\u003c\/strong\u003e Use the \u003ca href=\"\/products\/grundfos-cu-302-constant-pressure-control\"\u003eGrundfos CU 302 Constant Pressure Control\u003c\/a\u003e, sold with or without its 0-120 PSI pressure sensor, plus a 2 gal diaphragm tank. Variable speed needs the CU 302.\u003c\/p\u003e\n\u003cp style=\"margin:0 0 6px\"\u003e\u003cstrong style=\"color:#B3122A\"\u003eWithout a controller:\u003c\/strong\u003e Grundfos states the motor can be connected directly to the main breaker and started by a pressure switch rated for the pump's current; it then runs at full speed, like an SQ, with no constant pressure.\u003c\/p\u003e\n\u003cp style=\"margin:0 0 6px\"\u003e\u003cstrong style=\"color:#B3122A\"\u003eNever connect:\u003c\/strong\u003e a capacitor, a conventional control box or an external frequency drive.\u003c\/p\u003e\n\u003cp style=\"margin:0\"\u003e\u003cstrong style=\"color:#B3122A\"\u003eDrop cable and splice kit:\u003c\/strong\u003e sized to your setting depth (cable table under Models \u0026amp; Performance) and ordered separately. A replacement motor cable is on our \u003ca href=\"\/products\/grundfos-sq-sqe-pump-accessories\"\u003eGrundfos SQ and SQE Pump Accessories\u003c\/a\u003e listing; you do not need one for a new pump.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"background:#E1E3E6;border-left:3px solid #B8BDC4;padding:8px 14px;font-size:11.5px;color:#4A4A4F;margin-top:14px;line-height:1.5\"\u003eGenuine Grundfos equipment, factory-new in original packaging — sold and supported by Watermain Supply, an independent industrial supplier.\u003c\/div\u003e\n\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eWarranty\u003c\/div\u003e\n\u003cdiv class=\"gs-lead\"\u003e\u003cp\u003e24 months from date of installation, but not more than 30 months from date of manufacture. In Grundfos's words, products are “warranted to the original user only to be free of defects in material and workmanship”; the full terms are in the installation and operating instructions on the Data Sheet tab.\u003c\/p\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eSpecifications\u003c\/div\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated flow\u003c\/td\u003e\n\u003ctd\u003e5 GPM nominal; working range 1.5-8 GPM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHorsepower\u003c\/td\u003e\n\u003ctd\u003e1\/2 to 1-1\/2 HP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply\u003c\/td\u003e\n\u003ctd\u003e1 x 100-115 V (1\/2 HP only) or 1 x 200-240 V, 60 Hz; 2-wire plus ground\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor\u003c\/td\u003e\n\u003ctd\u003eMSE 3 permanent-magnet motor with built-in electronics, 3,000 to 10,700 rpm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl\u003c\/td\u003e\n\u003ctd\u003eCU 302 over the power leads (GENIbus); Bluetooth to Grundfos GO and the Grundfos HOME app\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection\u003c\/td\u003e\n\u003ctd\u003eDry run, overvoltage and undervoltage (cuts out below 150 V and above 315 V), overload, locked rotor, over-temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStarting\u003c\/td\u003e\n\u003ctd\u003eSoft start, run-up maximum 3 seconds; no limit on starts or stops per hour\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor cable\u003c\/td\u003e\n\u003ctd\u003e3-wire, 14 AWG XLPE, 5 ft, with plug\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDischarge\u003c\/td\u003e\n\u003ctd\u003e1 in NPT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWell diameter\u003c\/td\u003e\n\u003ctd\u003e3 in minimum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSetting depth\u003c\/td\u003e\n\u003ctd\u003eUp to 500 ft below the static water level; at least 20 in below the pumping water level\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePumped liquid\u003c\/td\u003e\n\u003ctd\u003eClean water, pH 5 to 9, up to 86°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGenerator\u003c\/td\u003e\n\u003ctd\u003eOutput at least the motor input power (P1) plus 50% recommended, never less than P1 plus 10%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"font-size:12.5px;color:#9B9EA3;margin-top:8px;line-height:1.55\"\u003eSource: Grundfos SQ, SQE, SmartFlo and SP data booklet (North America, 60 Hz), technical data.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eModels \u0026amp; Performance — Will It Do What You Need?\u003c\/div\u003e\n\u003cp style=\"font-size:13.5px;margin-bottom:10px\"\u003ePick a model whose head at your flow covers the pumping water level, the pressure you need at the surface (2.31 ft per PSI) and pipe friction. Then check the set-pressure table for what it delivers at your depth.\u003c\/p\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003cth\u003eHP\u003c\/th\u003e\n\u003cth\u003e0 GPM (Shut-off)\u003c\/th\u003e\n\u003cth\u003e1.5 GPM\u003c\/th\u003e\n\u003cth\u003e3.7 GPM\u003c\/th\u003e\n\u003cth\u003e5 GPM (Rated)\u003c\/th\u003e\n\u003cth\u003e7.4 GPM (Max)\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e5 SQE05-90\u003c\/td\u003e\n\u003ctd\u003e1\/2\u003c\/td\u003e\n\u003ctd\u003e153\u003c\/td\u003e\n\u003ctd\u003e147\u003c\/td\u003e\n\u003ctd\u003e121\u003c\/td\u003e\n\u003ctd\u003e86\u003c\/td\u003e\n\u003ctd\u003e46\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5 SQE05-140\u003c\/td\u003e\n\u003ctd\u003e1\/2\u003c\/td\u003e\n\u003ctd\u003e230\u003c\/td\u003e\n\u003ctd\u003e222\u003c\/td\u003e\n\u003ctd\u003e185\u003c\/td\u003e\n\u003ctd\u003e131\u003c\/td\u003e\n\u003ctd\u003e77\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5 SQE05-180\u003c\/td\u003e\n\u003ctd\u003e1\/2\u003c\/td\u003e\n\u003ctd\u003e309\u003c\/td\u003e\n\u003ctd\u003e298\u003c\/td\u003e\n\u003ctd\u003e249\u003c\/td\u003e\n\u003ctd\u003e177\u003c\/td\u003e\n\u003ctd\u003e108\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5 SQE07-230\u003c\/td\u003e\n\u003ctd\u003e3\/4\u003c\/td\u003e\n\u003ctd\u003e387\u003c\/td\u003e\n\u003ctd\u003e374\u003c\/td\u003e\n\u003ctd\u003e314\u003c\/td\u003e\n\u003ctd\u003e222\u003c\/td\u003e\n\u003ctd\u003e138\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5 SQE07-270\u003c\/td\u003e\n\u003ctd\u003e3\/4\u003c\/td\u003e\n\u003ctd\u003e465\u003c\/td\u003e\n\u003ctd\u003e450\u003c\/td\u003e\n\u003ctd\u003e379\u003c\/td\u003e\n\u003ctd\u003e270\u003c\/td\u003e\n\u003ctd\u003e169\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5 SQE07-320\u003c\/td\u003e\n\u003ctd\u003e3\/4\u003c\/td\u003e\n\u003ctd\u003e543\u003c\/td\u003e\n\u003ctd\u003e526\u003c\/td\u003e\n\u003ctd\u003e443\u003c\/td\u003e\n\u003ctd\u003e315\u003c\/td\u003e\n\u003ctd\u003e200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5 SQE10-360\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003ctd\u003e621\u003c\/td\u003e\n\u003ctd\u003e601\u003c\/td\u003e\n\u003ctd\u003e508\u003c\/td\u003e\n\u003ctd\u003e360\u003c\/td\u003e\n\u003ctd\u003e230\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5 SQE10-410\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003ctd\u003e700\u003c\/td\u003e\n\u003ctd\u003e678\u003c\/td\u003e\n\u003ctd\u003e572\u003c\/td\u003e\n\u003ctd\u003e405\u003c\/td\u003e\n\u003ctd\u003e260\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5 SQE15-450\u003c\/td\u003e\n\u003ctd\u003e1-1\/2\u003c\/td\u003e\n\u003ctd\u003e777\u003c\/td\u003e\n\u003ctd\u003e753\u003c\/td\u003e\n\u003ctd\u003e636\u003c\/td\u003e\n\u003ctd\u003e450\u003c\/td\u003e\n\u003ctd\u003e291\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"font-size:12.5px;color:#9B9EA3;margin-top:8px;line-height:1.55\"\u003eTotal head in feet. The shut-off and flow columns are read from the Grundfos 60 Hz curves for the 5 SQ, SQE (SQ and SQE share one curve, the SQE at its 10,700 rpm top speed), digitized from the published curve charts in the Grundfos SQ, SQE, SmartFlo and SP data booklet, at the nearest published point and rounded down. The (Rated) column is the head Grundfos prints at 5 GPM in its system sizing matrix, verbatim; the number in the model name is a nominal figure and reads lower on some models. On the 5 SQ, the published curve reads above the sizing-matrix head at 5 GPM (about 51 ft on the median model); both are shown as published, and we check your duty point against the curve before you order. 1 ft of head = 0.433 PSI. Full curves are in the product images and on the Data Sheet tab.\u003c\/p\u003e\n\u003cp style=\"font-size:13.5px;margin-bottom:10px;margin-top:18px\"\u003e\u003cstrong\u003eWhat It Delivers at Your Set Pressure\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdetails open style=\"margin:8px 0;border-top:3px solid #B3122A;padding:0 4px 6px\"\u003e\u003csummary style=\"cursor:pointer;padding:8px 0;font-weight:bold;color:#4A4A4F\"\u003eOutput at 50 and 60 PSI · 1\/2 to 3\/4 HP · 6 models · depths 20 to 400 ft\u003c\/summary\u003e\n\u003cp\u003e\u003cstrong\u003eGPM at 50 PSI\u003c\/strong\u003e (CU 302 factory setpoint), by depth to water\u003c\/p\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003cth\u003e20 ft\u003c\/th\u003e\n\u003cth\u003e80 ft\u003c\/th\u003e\n\u003cth\u003e120 ft\u003c\/th\u003e\n\u003cth\u003e180 ft\u003c\/th\u003e\n\u003cth\u003e240 ft\u003c\/th\u003e\n\u003cth\u003e280 ft\u003c\/th\u003e\n\u003cth\u003e400 ft\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e5 SQE05-90\u003c\/td\u003e\n\u003ctd\u003e2.8\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5 SQE05-140\u003c\/td\u003e\n\u003ctd\u003e5.7\u003c\/td\u003e\n\u003ctd\u003e3.3\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5 SQE05-180\u003c\/td\u003e\n\u003ctd\u003e6.8\u003c\/td\u003e\n\u003ctd\u003e5.4\u003c\/td\u003e\n\u003ctd\u003e4.3\u003c\/td\u003e\n\u003ctd\u003e1.7\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5 SQE07-230*\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e6\u003c\/td\u003e\n\u003ctd\u003e5.5\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5 SQE07-270\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e7\u003c\/td\u003e\n\u003ctd\u003e6.4\u003c\/td\u003e\n\u003ctd\u003e5.4\u003c\/td\u003e\n\u003ctd\u003e4.3\u003c\/td\u003e\n\u003ctd\u003e3.4\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5 SQE07-320\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e7.5\u003c\/td\u003e\n\u003ctd\u003e7\u003c\/td\u003e\n\u003ctd\u003e6.2\u003c\/td\u003e\n\u003ctd\u003e5.4\u003c\/td\u003e\n\u003ctd\u003e4.7\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp\u003e\u003cstrong\u003eGPM at 60 PSI\u003c\/strong\u003e (setpoint), by depth to water\u003c\/p\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003cth\u003e20 ft\u003c\/th\u003e\n\u003cth\u003e80 ft\u003c\/th\u003e\n\u003cth\u003e120 ft\u003c\/th\u003e\n\u003cth\u003e180 ft\u003c\/th\u003e\n\u003cth\u003e240 ft\u003c\/th\u003e\n\u003cth\u003e280 ft\u003c\/th\u003e\n\u003cth\u003e400 ft\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e5 SQE05-90\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5 SQE05-140\u003c\/td\u003e\n\u003ctd\u003e4.9\u003c\/td\u003e\n\u003ctd\u003e1.8\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5 SQE05-180\u003c\/td\u003e\n\u003ctd\u003e6.4\u003c\/td\u003e\n\u003ctd\u003e4.8\u003c\/td\u003e\n\u003ctd\u003e3.5\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5 SQE07-230*\u003c\/td\u003e\n\u003ctd\u003e7\u003c\/td\u003e\n\u003ctd\u003e5.5\u003c\/td\u003e\n\u003ctd\u003e5\u003c\/td\u003e\n\u003ctd\u003e3.5\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5 SQE07-270\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e6.6\u003c\/td\u003e\n\u003ctd\u003e6\u003c\/td\u003e\n\u003ctd\u003e5\u003c\/td\u003e\n\u003ctd\u003e3.8\u003c\/td\u003e\n\u003ctd\u003e2.7\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5 SQE07-320\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e7.2\u003c\/td\u003e\n\u003ctd\u003e6.7\u003c\/td\u003e\n\u003ctd\u003e5.9\u003c\/td\u003e\n\u003ctd\u003e5\u003c\/td\u003e\n\u003ctd\u003e4.3\u003c\/td\u003e\n\u003ctd\u003e0.9\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails style=\"margin:8px 0;border-top:3px solid #B3122A;padding:0 4px 6px\"\u003e\u003csummary style=\"cursor:pointer;padding:8px 0;font-weight:bold;color:#4A4A4F\"\u003eOutput at 50 and 60 PSI · 1 to 1-1\/2 HP · 3 models · depths 100 to 600 ft\u003c\/summary\u003e\n\u003cp\u003e\u003cstrong\u003eGPM at 50 PSI\u003c\/strong\u003e (CU 302 factory setpoint), by depth to water\u003c\/p\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003cth\u003e100 ft\u003c\/th\u003e\n\u003cth\u003e140 ft\u003c\/th\u003e\n\u003cth\u003e200 ft\u003c\/th\u003e\n\u003cth\u003e260 ft\u003c\/th\u003e\n\u003cth\u003e300 ft\u003c\/th\u003e\n\u003cth\u003e400 ft\u003c\/th\u003e\n\u003cth\u003e600 ft\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e5 SQE10-360\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e7.1\u003c\/td\u003e\n\u003ctd\u003e6.5\u003c\/td\u003e\n\u003ctd\u003e5.8\u003c\/td\u003e\n\u003ctd\u003e5.3\u003c\/td\u003e\n\u003ctd\u003e3.7\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5 SQE10-410\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e7.5\u003c\/td\u003e\n\u003ctd\u003e6.9\u003c\/td\u003e\n\u003ctd\u003e6.3\u003c\/td\u003e\n\u003ctd\u003e5.9\u003c\/td\u003e\n\u003ctd\u003e4.7\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5 SQE15-450\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e7.2\u003c\/td\u003e\n\u003ctd\u003e6.7\u003c\/td\u003e\n\u003ctd\u003e6.3\u003c\/td\u003e\n\u003ctd\u003e5.3\u003c\/td\u003e\n\u003ctd\u003e2.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp\u003e\u003cstrong\u003eGPM at 60 PSI\u003c\/strong\u003e (setpoint), by depth to water\u003c\/p\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003cth\u003e100 ft\u003c\/th\u003e\n\u003cth\u003e140 ft\u003c\/th\u003e\n\u003cth\u003e200 ft\u003c\/th\u003e\n\u003cth\u003e260 ft\u003c\/th\u003e\n\u003cth\u003e300 ft\u003c\/th\u003e\n\u003cth\u003e400 ft\u003c\/th\u003e\n\u003cth\u003e600 ft\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e5 SQE10-360\u003c\/td\u003e\n\u003ctd\u003e7.4\u003c\/td\u003e\n\u003ctd\u003e6.9\u003c\/td\u003e\n\u003ctd\u003e6.3\u003c\/td\u003e\n\u003ctd\u003e5.5\u003c\/td\u003e\n\u003ctd\u003e5\u003c\/td\u003e\n\u003ctd\u003e3.2\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5 SQE10-410\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e7.3\u003c\/td\u003e\n\u003ctd\u003e6.7\u003c\/td\u003e\n\u003ctd\u003e6\u003c\/td\u003e\n\u003ctd\u003e5.6\u003c\/td\u003e\n\u003ctd\u003e4.4\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5 SQE15-450\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e7\u003c\/td\u003e\n\u003ctd\u003e6.5\u003c\/td\u003e\n\u003ctd\u003e6.1\u003c\/td\u003e\n\u003ctd\u003e5\u003c\/td\u003e\n\u003ctd\u003e1.9\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cp style=\"font-size:12.5px;color:#9B9EA3;margin-top:8px;line-height:1.55\"\u003eFrom the Grundfos 3 in SQ sizing charts (pp. 36-37), verbatim: gallons per minute at the pressure shown and the depth to pumping water level. The SQE runs on the same curve as the SQ at full speed, so each cell is the most the SQE delivers while the CU 302 holds that pressure. Riser and pipe friction are not included. A dash means Grundfos prints no figure: on the shallow side the flow is past the chart range, on the deep side the pump cannot hold that pressure. * 5 SQE07-230: Grundfos's printed chart for this model repeats the 5 SQ07-270 figures and disagrees with the model's own published curve by about 48 ft of head on average, so its row is calculated from the curve instead. Calculated rows are the flow where the published curve meets the depth plus 116 ft or 139 ft, interpolated between published points and rounded down to 0.5 GPM.\u003c\/p\u003e\n\u003cp style=\"font-size:13.5px;margin-bottom:10px;margin-top:18px\"\u003e\u003cstrong\u003eDrop Cable Size\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdetails style=\"margin:8px 0;border-top:3px solid #B3122A;padding:0 4px 6px\"\u003e\u003csummary style=\"cursor:pointer;padding:8px 0;font-weight:bold;color:#4A4A4F\"\u003eDrop cable size by distance · copper, 60 Hz\u003c\/summary\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eVolts\u003c\/th\u003e\n\u003cth\u003eHP\u003c\/th\u003e\n\u003cth\u003eAmps\u003c\/th\u003e\n\u003cth\u003e14 AWG\u003c\/th\u003e\n\u003cth\u003e12 AWG\u003c\/th\u003e\n\u003cth\u003e10 AWG\u003c\/th\u003e\n\u003cth\u003e8 AWG\u003c\/th\u003e\n\u003cth\u003e6 AWG\u003c\/th\u003e\n\u003cth\u003e4 AWG\u003c\/th\u003e\n\u003cth\u003e2 AWG\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e115\u003c\/td\u003e\n\u003ctd\u003e1\/2\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003ctd\u003e140\u003c\/td\u003e\n\u003ctd\u003e220\u003c\/td\u003e\n\u003ctd\u003e360\u003c\/td\u003e\n\u003ctd\u003e550\u003c\/td\u003e\n\u003ctd\u003e880\u003c\/td\u003e\n\u003ctd\u003e1390\u003c\/td\u003e\n\u003ctd\u003e2260\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e230\u003c\/td\u003e\n\u003ctd\u003e1\/2\u003c\/td\u003e\n\u003ctd\u003e5.2\u003c\/td\u003e\n\u003ctd\u003e640\u003c\/td\u003e\n\u003ctd\u003e1000\u003c\/td\u003e\n\u003ctd\u003e1660\u003c\/td\u003e\n\u003ctd\u003e2250\u003c\/td\u003e\n\u003ctd\u003e4060\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e230\u003c\/td\u003e\n\u003ctd\u003e3\/4\u003c\/td\u003e\n\u003ctd\u003e8.4\u003c\/td\u003e\n\u003ctd\u003e400\u003c\/td\u003e\n\u003ctd\u003e620\u003c\/td\u003e\n\u003ctd\u003e1030\u003c\/td\u003e\n\u003ctd\u003e1580\u003c\/td\u003e\n\u003ctd\u003e2510\u003c\/td\u003e\n\u003ctd\u003e3970\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e230\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003ctd\u003e11.2\u003c\/td\u003e\n\u003ctd\u003e300\u003c\/td\u003e\n\u003ctd\u003e460\u003c\/td\u003e\n\u003ctd\u003e770\u003c\/td\u003e\n\u003ctd\u003e1190\u003c\/td\u003e\n\u003ctd\u003e1890\u003c\/td\u003e\n\u003ctd\u003e2980\u003c\/td\u003e\n\u003ctd\u003e4850\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e230\u003c\/td\u003e\n\u003ctd\u003e1-1\/2\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003ctd\u003e280\u003c\/td\u003e\n\u003ctd\u003e430\u003c\/td\u003e\n\u003ctd\u003e720\u003c\/td\u003e\n\u003ctd\u003e1110\u003c\/td\u003e\n\u003ctd\u003e1760\u003c\/td\u003e\n\u003ctd\u003e2780\u003c\/td\u003e\n\u003ctd\u003e4530\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"font-size:12.5px;color:#9B9EA3;margin-top:8px;line-height:1.55\"\u003eMaximum length in feet from the motor to the service entrance, copper wire, 9% voltage drop, from the Grundfos SQ, SQE installation and operating instructions and data booklet. A dash means not listed.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdiv style=\"display:flex;flex-wrap:wrap;gap:10px;margin:22px 0 4px\"\u003e\n\u003ca href=\"\/pages\/submersible-well-pump-sizing-calculator\" style=\"flex:1 1 200px;text-align:center;display:block;background:#B3122A;color:#ffffff;font-family:Arial Black,Arial,sans-serif;font-size:12px;text-transform:uppercase;letter-spacing:1.2px;padding:11px 18px;text-decoration:none\"\u003eSubmersible Calculator\u003c\/a\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eBefore You Buy — The Limits That Decide the Fit\u003c\/div\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eCheck\u003c\/th\u003e\n\u003cth\u003eWhat to confirm\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eWell size\u003c\/td\u003e\n\u003ctd\u003e3 in or larger casing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWater\u003c\/td\u003e\n\u003ctd\u003eClean water, pH 5 to 9, up to 86°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSetting\u003c\/td\u003e\n\u003ctd\u003eNo deeper than 500 ft below the static water level, and at least 20 in below the pumping water level\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower\u003c\/td\u003e\n\u003ctd\u003e1\/2 HP models come in 115 V or 230 V versions (different part numbers, not field-convertible); 3\/4 HP and up are 230 V only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWiring\u003c\/td\u003e\n\u003ctd\u003eCU 302 for constant pressure; or a pressure switch rated for the pump's current. Never a capacitor, control box or external drive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHorizontal install\u003c\/td\u003e\n\u003ctd\u003eUse the SQ\/SQE flow sleeve (on our \u003ca href=\"\/products\/grundfos-sq-sqe-pump-accessories\"\u003eGrundfos SQ and SQE Pump Accessories\u003c\/a\u003e listing) to keep water moving past the motor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGenerator\u003c\/td\u003e\n\u003ctd\u003eAt least the motor input power plus 50% (minimum plus 10%)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eMaterials of Construction\u003c\/div\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003ePart\u003c\/th\u003e\n\u003cth\u003eMaterial\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePump sleeve, outlet chamber, cable guard\u003c\/td\u003e\n\u003ctd\u003eAISI 304 stainless steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eImpellers, chambers, guide vanes, valve casing\u003c\/td\u003e\n\u003ctd\u003ePolyamide (30% glass-fibre reinforced)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eImpeller bearings\u003c\/td\u003e\n\u003ctd\u003eTungsten carbide \/ ceramic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShaft\u003c\/td\u003e\n\u003ctd\u003eAISI 304 stainless steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eValve seat, seals\u003c\/td\u003e\n\u003ctd\u003eNBR rubber\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor stator, rotor, top cover\u003c\/td\u003e\n\u003ctd\u003eAISI 304 stainless steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor bearings\u003c\/td\u003e\n\u003ctd\u003eSilicon carbide \/ tungsten carbide (coated); carbon thrust bearing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"font-size:12.5px;color:#9B9EA3;margin-top:8px;line-height:1.55\"\u003eSource: Grundfos SQ, SQE, SmartFlo and SP data booklet, construction.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"gs-contact\"\u003eFor engineering-led sizing and selection support or a factory submittal, email \u003ca href=\"mailto:sales@watermainsupply.com\"\u003esales@watermainsupply.com\u003c\/a\u003e or call \u003ca href=\"tel:18885104036\"\u003e1-888.510.4036\u003c\/a\u003e.\u003cbr\u003e© Watermain Supply — A division of E4 Industrial LLC\u003c\/div\u003e\n\n\u003c\/div\u003e\n\u003ch5\u003eData Sheet\u003c\/h5\u003e\u003cdiv class=\"gs\"\u003e\u003cdiv class=\"gs-dl\"\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0264\/1913\/4527\/files\/SQ_SQE_us.pdf?v=1788826864\" target=\"_blank\" rel=\"noopener\"\u003eSQ, SQE Installation and Operating Instructions\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0264\/1913\/4527\/files\/SQE_Brochure_2.pdf?v=1788826864\" target=\"_blank\" rel=\"noopener\"\u003eGrundfos SQE Constant Pressure Groundwater System Brochure\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0264\/1913\/4527\/files\/SQ_SQE_Brochure.pdf?v=1788826865\" target=\"_blank\" rel=\"noopener\"\u003eGrundfos SQ\/SQE Range Brochure\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0264\/1913\/4527\/files\/SQ_Performance_Curves.pdf?v=1788826864\" target=\"_blank\" rel=\"noopener\"\u003e3 in SQ Sizing Guide — Curves and Sizing Charts\u003c\/a\u003e\n\u003c\/div\u003e\u003c\/div\u003e\u003ch5\u003eVideos\u003c\/h5\u003e\u003cdiv class=\"gs\"\u003e\u003cdiv class=\"gs-sec\" style=\"margin-top:6px\"\u003e\n\u003cdiv style=\"display:grid;grid-template-columns:repeat(auto-fit,minmax(300px,1fr));gap:20px\"\u003e\n\u003cdiv\u003e\n\u003cdiv style=\"position:relative;width:100%;padding-top:56.25%;background:#4A4A4F\"\u003e\u003ciframe src=\"https:\/\/www.youtube.com\/embed\/_Kn3OVDRZOE?si=3DToNwIsKFSrV9Bt\" title=\"SQ and SQE: Constant Pressure Pump Overview\" loading=\"lazy\" frameborder=\"0\" style=\"position:absolute;top:0;left:0;width:100%;height:100%;border:0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share\" referrerpolicy=\"strict-origin-when-cross-origin\" allowfullscreen\u003e\u003c\/iframe\u003e\u003c\/div\u003e\n\u003cp style=\"font-family:Arial,Helvetica,sans-serif;font-size:13px;line-height:1.45;color:#4A4A4F;margin:8px 0 0\"\u003eSQ and SQE: Constant Pressure Pump Overview \u003cspan style=\"color:#9B9EA3\"\u003e(4:02)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cdiv style=\"position:relative;width:100%;padding-top:56.25%;background:#4A4A4F\"\u003e\u003ciframe src=\"https:\/\/www.youtube.com\/embed\/lHPdSndKQqs?si=tktPTsRHA2Z-H07V\" title=\"Installing a Grundfos SQE Constant Pressure System\" loading=\"lazy\" frameborder=\"0\" style=\"position:absolute;top:0;left:0;width:100%;height:100%;border:0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share\" referrerpolicy=\"strict-origin-when-cross-origin\" allowfullscreen\u003e\u003c\/iframe\u003e\u003c\/div\u003e\n\u003cp style=\"font-family:Arial,Helvetica,sans-serif;font-size:13px;line-height:1.45;color:#4A4A4F;margin:8px 0 0\"\u003eInstalling a Grundfos SQE Constant Pressure System \u003cspan style=\"color:#9B9EA3\"\u003e(5:22)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cdiv style=\"position:relative;width:100%;padding-top:56.25%;background:#4A4A4F\"\u003e\u003ciframe src=\"https:\/\/www.youtube.com\/embed\/U4gomM0GLr0?si=CP3NowIBbbzTzjEP\" title=\"Grundfos SQE Pump Restores Clean Water to a California Family\" loading=\"lazy\" frameborder=\"0\" style=\"position:absolute;top:0;left:0;width:100%;height:100%;border:0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share\" referrerpolicy=\"strict-origin-when-cross-origin\" allowfullscreen\u003e\u003c\/iframe\u003e\u003c\/div\u003e\n\u003cp style=\"font-family:Arial,Helvetica,sans-serif;font-size:13px;line-height:1.45;color:#4A4A4F;margin:8px 0 0\"\u003eGrundfos SQE Pump Restores Clean Water to a California Family \u003cspan style=\"color:#9B9EA3\"\u003e(6:42)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp style=\"font-family:Arial,Helvetica,sans-serif;font-size:12px;color:#9B9EA3;margin:16px 0 0\"\u003eVideos produced by Grundfos and hosted on YouTube.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/div\u003e\u003ch5\u003eGrundfos HOME App\u003c\/h5\u003e\u003cdiv class=\"gs\"\u003e\u003cdiv class=\"gs-sec\" style=\"margin-top:6px\"\u003e\n\u003cdiv class=\"gs-h\"\u003eSet Up \u0026amp; Monitor From Your Phone\u003c\/div\u003e\n\u003cdiv class=\"gs-lead\"\u003e\u003cp\u003eThe free Grundfos HOME app gives you full control of your water system from an iOS or Android phone. Pair an SQE with a CU 302 control unit and the app reports pump information around the clock, sends alert notifications on important events so you can act before the water goes off, and carries a built-in watering calendar with an internal clock so irrigation routines run to schedule without a timer. Installer details are stored in the app, so whoever set the system up is one tap away.\u003c\/p\u003e\u003c\/div\u003e\n\u003cdiv style=\"margin-top:16px\"\u003e\n\u003ca href=\"https:\/\/apps.apple.com\/us\/app\/grundfos-home\/id1592451846\" target=\"_blank\" rel=\"noopener\" style=\"display:inline-block;background:#B3122A;color:#fff!important;font-family:Arial Black,Arial,sans-serif;font-size:13px;letter-spacing:1px;text-transform:uppercase;text-decoration:none;padding:12px 24px;border-radius:999px;margin:0 10px 10px 0\"\u003eDownload for iOS\u003c\/a\u003e\u003ca href=\"https:\/\/play.google.com\/store\/apps\/details?id=com.grundfos.home\u0026amp;pcampaignid=web_share\" target=\"_blank\" rel=\"noopener\" style=\"display:inline-block;background:#4A4A4F;color:#fff!important;font-family:Arial Black,Arial,sans-serif;font-size:13px;letter-spacing:1px;text-transform:uppercase;text-decoration:none;padding:12px 24px;border-radius:999px;margin:0 10px 10px 0\"\u003eDownload for Android\u003c\/a\u003e\n\u003c\/div\u003e\n\u003cp style=\"font-size:12px;color:#9B9EA3;margin-top:14px;line-height:1.6\"\u003eGrundfos HOME is a free app from Grundfos Holding A\/S. It connects through the CU 302 control unit, which is required and is sold separately, and Bluetooth must be enabled on the CU 302 operating panel before pairing. Installers and service technicians use a separate free Grundfos app, Grundfos GO, as the commissioning and diagnostic tool; ask us for the link if you need it.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/div\u003e\u003c!-- \/TABS --\u003e","brand":"Grundfos","offers":[{"title":"1\/2 HP - 3 in Motor \/ 115V 1Ph 2-Wire \/ 5 SQE05-90 - 86 ft at 5 GPM","offer_id":47457479164079,"sku":"96160206","price":1407.49,"currency_code":"USD","in_stock":true},{"title":"1\/2 HP - 3 in Motor \/ 115V 1Ph 2-Wire \/ 5 SQE05-140 - 131 ft at 5 GPM","offer_id":47457479196847,"sku":"96160207","price":1430.68,"currency_code":"USD","in_stock":true},{"title":"1\/2 HP - 3 in Motor \/ 115V 1Ph 2-Wire \/ 5 SQE05-180 - 177 ft at 5 GPM","offer_id":47457479229615,"sku":"96160208","price":1458.25,"currency_code":"USD","in_stock":true},{"title":"1\/2 HP - 3 in Motor \/ 230V 1Ph 2-Wire \/ 5 SQE05-90 - 86 ft at 5 GPM","offer_id":47457479262383,"sku":"96160173","price":1407.49,"currency_code":"USD","in_stock":true},{"title":"1\/2 HP - 3 in Motor \/ 230V 1Ph 2-Wire \/ 5 SQE05-140 - 131 ft at 5 GPM","offer_id":47457479295151,"sku":"96160174","price":1430.68,"currency_code":"USD","in_stock":true},{"title":"1\/2 HP - 3 in Motor \/ 230V 1Ph 2-Wire \/ 5 SQE05-180 - 177 ft at 5 GPM","offer_id":47457479327919,"sku":"96160175","price":1458.25,"currency_code":"USD","in_stock":true},{"title":"3\/4 HP - 3 in Motor \/ 230V 1Ph 2-Wire \/ 5 SQE07-230 - 222 ft at 5 GPM","offer_id":47457479360687,"sku":"96160176","price":1737.75,"currency_code":"USD","in_stock":true},{"title":"3\/4 HP - 3 in Motor \/ 230V 1Ph 2-Wire \/ 5 SQE07-270 - 270 ft at 5 GPM","offer_id":47457479393455,"sku":"96160177","price":1768.45,"currency_code":"USD","in_stock":true},{"title":"3\/4 HP - 3 in Motor \/ 230V 1Ph 2-Wire \/ 5 SQE07-320 - 315 ft at 5 GPM","offer_id":47457479426223,"sku":"96160178","price":1797.28,"currency_code":"USD","in_stock":true},{"title":"1 HP - 3 in Motor \/ 230V 1Ph 2-Wire \/ 5 SQE10-360 - 360 ft at 5 GPM","offer_id":47457479458991,"sku":"96160179","price":2041.05,"currency_code":"USD","in_stock":true},{"title":"1 HP - 3 in Motor \/ 230V 1Ph 2-Wire \/ 5 SQE10-410 - 405 ft at 5 GPM","offer_id":47457479491759,"sku":"96160180","price":2129.41,"currency_code":"USD","in_stock":true},{"title":"1-1\/2 HP - 3 in Motor \/ 230V 1Ph 2-Wire \/ 5 SQE15-450 - 450 ft at 5 GPM","offer_id":47457479524527,"sku":"96160181","price":2153.85,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0264\/1913\/4527\/files\/Grundfos_SQE_Submersible_Pump.webp?v=1788826893"},{"product_id":"grundfos-10-sqe-submersible-well-pump","title":"Grundfos 10 SQE Submersible Well Pump","description":"\u003c!-- TABS --\u003e\n\u003ch5\u003eDescription\u003c\/h5\u003e\n\u003cdiv class=\"gs\"\u003e\n\n\u003cdiv class=\"gs-head\"\u003e\n\u003cdiv class=\"gs-eyebrow\"\u003eGrundfos · 3 in Submersible Well Pump\u003c\/div\u003e\n\u003cdiv class=\"gs-title\"\u003e10 SQE\u003c\/div\u003e\n\u003cdiv class=\"gs-sub\"\u003eNominal 10 GPM 3 in constant-pressure submersible well pump with a permanent-magnet motor and built-in protection: 7 models from 1\/2 to 1-1\/2 HP, 105-434 ft of head at 10 GPM, 1-1\/4 in NPT discharge. Runs on a CU 302 for constant pressure.\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"gs-badges\"\u003e\n\u003cdiv class=\"gs-badge\" style=\"background:#B3122A;color:#FFFFFF;border-color:#B3122A\"\u003e10 GPM Rated Flow\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003e1\/2 to 1-1\/2 HP\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003e105-434 ft at 10 GPM\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003e3-15 GPM Flow Range\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003eConstant Pressure with CU 302\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003e3 in Min. Well\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003e1-1\/4 in NPT Discharge\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003e115V or 230V 1Ph\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003eDry-Run, Voltage and Overload Protection\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003e2.9 in Dia x 29.1-37.0 in L\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003e11-16 lb Ship Weight\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eOverview\u003c\/div\u003e\n\u003cdiv class=\"gs-lead\"\u003e\n\u003cp\u003eThe Grundfos 10 SQE is a 3 in stainless steel well pump with a variable-speed permanent-magnet \"Smart Motor\". Paired with a \u003ca href=\"\/products\/grundfos-cu-302-constant-pressure-control\"\u003eGrundfos CU 302 Constant Pressure Control\u003c\/a\u003e, it holds the pressure you set, from a trickle at one tap to full flow, instead of cycling between a pressure switch's cut-in and cut-out. The CU 302 talks to the pump over the power leads, so no extra wires go down the well, and it pairs with the Grundfos GO and HOME apps by Bluetooth.\u003c\/p\u003e\n\u003cp\u003eIt is rated at 10 GPM, with 7 models from 1\/2 to 1-1\/2 HP for deeper settings. The pump fits a 3 in or larger well and suits household supply, light commercial service, irrigation and tank filling or emptying.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eConstant pressure.\u003c\/strong\u003e The CU 302 changes pump speed, 3,000 to 10,700 rpm, to hold its setpoint (factory 50 PSI, adjustable 20 to 100 PSI in 5 PSI steps). It works with a 2 gal diaphragm tank instead of a large pressure tank.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBuilt-in protection.\u003c\/strong\u003e Dry-run, over- and undervoltage (cuts out below 150 V and above 315 V and restarts by itself), overload, locked-rotor and over-temperature protection are built into the motor. No protection relay or motor starter needed.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSoft start, no start limit.\u003c\/strong\u003e The motor ramps up in about 3 seconds and has no limit on starts or stops per hour.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSand-tolerant hydraulics.\u003c\/strong\u003e Floating impellers each run on their own tungsten carbide \/ ceramic bearing; a top bearing protects pump and motor against upthrust at start-up.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall it any way up.\u003c\/strong\u003e Vertical, horizontal or anywhere between, with a built-in spring check valve; use a flow sleeve when horizontal.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"background:#FFFFFF;border:1px solid #C7CBD1;border-top:3px solid #B3122A;padding:12px 16px 12px;margin:16px 0 4px;font-size:13.5px;line-height:1.55;color:#4A4A4F\"\u003e\n\u003cdiv style=\"font-family:Arial Black,Arial,sans-serif;font-size:11px;letter-spacing:1.2px;text-transform:uppercase;color:#B3122A;margin-bottom:8px\"\u003eWhat Ships and What It Needs to Run\u003c\/div\u003e\n\u003cp style=\"margin:0 0 6px\"\u003e\u003cstrong style=\"color:#B3122A\"\u003eIncluded:\u003c\/strong\u003e the pump and its 3 in SQE motor, assembled, with a built-in check valve, plus a 5 ft, 14 AWG motor cable with plug that you press onto the motor socket and secure with four screws. The controller is \u003cstrong\u003enot\u003c\/strong\u003e in the box.\u003c\/p\u003e\n\u003cp style=\"margin:0 0 6px\"\u003e\u003cstrong style=\"color:#B3122A\"\u003eFor constant pressure: CU 302 and a pressure sensor, ordered separately.\u003c\/strong\u003e Use the \u003ca href=\"\/products\/grundfos-cu-302-constant-pressure-control\"\u003eGrundfos CU 302 Constant Pressure Control\u003c\/a\u003e, sold with or without its 0-120 PSI pressure sensor, plus a 2 gal diaphragm tank. Variable speed needs the CU 302.\u003c\/p\u003e\n\u003cp style=\"margin:0 0 6px\"\u003e\u003cstrong style=\"color:#B3122A\"\u003eWithout a controller:\u003c\/strong\u003e Grundfos states the motor can be connected directly to the main breaker and started by a pressure switch rated for the pump's current; it then runs at full speed, like an SQ, with no constant pressure.\u003c\/p\u003e\n\u003cp style=\"margin:0 0 6px\"\u003e\u003cstrong style=\"color:#B3122A\"\u003eNever connect:\u003c\/strong\u003e a capacitor, a conventional control box or an external frequency drive.\u003c\/p\u003e\n\u003cp style=\"margin:0\"\u003e\u003cstrong style=\"color:#B3122A\"\u003eDrop cable and splice kit:\u003c\/strong\u003e sized to your setting depth (cable table under Models \u0026amp; Performance) and ordered separately. A replacement motor cable is on our \u003ca href=\"\/products\/grundfos-sq-sqe-pump-accessories\"\u003eGrundfos SQ and SQE Pump Accessories\u003c\/a\u003e listing; you do not need one for a new pump.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"background:#E1E3E6;border-left:3px solid #B8BDC4;padding:8px 14px;font-size:11.5px;color:#4A4A4F;margin-top:14px;line-height:1.5\"\u003eGenuine Grundfos equipment, factory-new in original packaging — sold and supported by Watermain Supply, an independent industrial supplier.\u003c\/div\u003e\n\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eWarranty\u003c\/div\u003e\n\u003cdiv class=\"gs-lead\"\u003e\u003cp\u003e24 months from date of installation, but not more than 30 months from date of manufacture. In Grundfos's words, products are “warranted to the original user only to be free of defects in material and workmanship”; the full terms are in the installation and operating instructions on the Data Sheet tab.\u003c\/p\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eSpecifications\u003c\/div\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated flow\u003c\/td\u003e\n\u003ctd\u003e10 GPM nominal; working range 3-15 GPM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHorsepower\u003c\/td\u003e\n\u003ctd\u003e1\/2 to 1-1\/2 HP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply\u003c\/td\u003e\n\u003ctd\u003e1 x 100-115 V (1\/2 HP only) or 1 x 200-240 V, 60 Hz; 2-wire plus ground\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor\u003c\/td\u003e\n\u003ctd\u003eMSE 3 permanent-magnet motor with built-in electronics, 3,000 to 10,700 rpm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl\u003c\/td\u003e\n\u003ctd\u003eCU 302 over the power leads (GENIbus); Bluetooth to Grundfos GO and the Grundfos HOME app\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection\u003c\/td\u003e\n\u003ctd\u003eDry run, overvoltage and undervoltage (cuts out below 150 V and above 315 V), overload, locked rotor, over-temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStarting\u003c\/td\u003e\n\u003ctd\u003eSoft start, run-up maximum 3 seconds; no limit on starts or stops per hour\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor cable\u003c\/td\u003e\n\u003ctd\u003e3-wire, 14 AWG XLPE, 5 ft, with plug\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDischarge\u003c\/td\u003e\n\u003ctd\u003e1-1\/4 in NPT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWell diameter\u003c\/td\u003e\n\u003ctd\u003e3 in minimum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSetting depth\u003c\/td\u003e\n\u003ctd\u003eUp to 500 ft below the static water level; at least 20 in below the pumping water level\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePumped liquid\u003c\/td\u003e\n\u003ctd\u003eClean water, pH 5 to 9, up to 86°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGenerator\u003c\/td\u003e\n\u003ctd\u003eOutput at least the motor input power (P1) plus 50% recommended, never less than P1 plus 10%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"font-size:12.5px;color:#9B9EA3;margin-top:8px;line-height:1.55\"\u003eSource: Grundfos SQ, SQE, SmartFlo and SP data booklet (North America, 60 Hz), technical data.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eModels \u0026amp; Performance — Will It Do What You Need?\u003c\/div\u003e\n\u003cp style=\"font-size:13.5px;margin-bottom:10px\"\u003ePick a model whose head at your flow covers the pumping water level, the pressure you need at the surface (2.31 ft per PSI) and pipe friction. Then check the set-pressure table for what it delivers at your depth.\u003c\/p\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003cth\u003eHP\u003c\/th\u003e\n\u003cth\u003e0 GPM (Shut-off)\u003c\/th\u003e\n\u003cth\u003e3 GPM\u003c\/th\u003e\n\u003cth\u003e7.5 GPM\u003c\/th\u003e\n\u003cth\u003e10 GPM (Rated)\u003c\/th\u003e\n\u003cth\u003e14.9 GPM (Max)\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e10 SQE05-110\u003c\/td\u003e\n\u003ctd\u003e1\/2\u003c\/td\u003e\n\u003ctd\u003e147\u003c\/td\u003e\n\u003ctd\u003e141\u003c\/td\u003e\n\u003ctd\u003e125\u003c\/td\u003e\n\u003ctd\u003e105\u003c\/td\u003e\n\u003ctd\u003e29\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e10 SQE05-160\u003c\/td\u003e\n\u003ctd\u003e1\/2\u003c\/td\u003e\n\u003ctd\u003e224\u003c\/td\u003e\n\u003ctd\u003e214\u003c\/td\u003e\n\u003ctd\u003e192\u003c\/td\u003e\n\u003ctd\u003e164\u003c\/td\u003e\n\u003ctd\u003e56\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e10 SQE07-200\u003c\/td\u003e\n\u003ctd\u003e3\/4\u003c\/td\u003e\n\u003ctd\u003e290\u003c\/td\u003e\n\u003ctd\u003e283\u003c\/td\u003e\n\u003ctd\u003e251\u003c\/td\u003e\n\u003ctd\u003e215\u003c\/td\u003e\n\u003ctd\u003e82\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e10 SQE07-240\u003c\/td\u003e\n\u003ctd\u003e3\/4\u003c\/td\u003e\n\u003ctd\u003e358\u003c\/td\u003e\n\u003ctd\u003e352\u003c\/td\u003e\n\u003ctd\u003e311\u003c\/td\u003e\n\u003ctd\u003e267\u003c\/td\u003e\n\u003ctd\u003e110\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e10 SQE10-290\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003ctd\u003e434\u003c\/td\u003e\n\u003ctd\u003e428\u003c\/td\u003e\n\u003ctd\u003e380\u003c\/td\u003e\n\u003ctd\u003e328\u003c\/td\u003e\n\u003ctd\u003e135\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e10 SQE15-330\u003c\/td\u003e\n\u003ctd\u003e1-1\/2\u003c\/td\u003e\n\u003ctd\u003e509\u003c\/td\u003e\n\u003ctd\u003e503\u003c\/td\u003e\n\u003ctd\u003e449\u003c\/td\u003e\n\u003ctd\u003e390\u003c\/td\u003e\n\u003ctd\u003e161\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e10 SQE15-370\u003c\/td\u003e\n\u003ctd\u003e1-1\/2\u003c\/td\u003e\n\u003ctd\u003e565\u003c\/td\u003e\n\u003ctd\u003e558\u003c\/td\u003e\n\u003ctd\u003e498\u003c\/td\u003e\n\u003ctd\u003e434\u003c\/td\u003e\n\u003ctd\u003e178\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"font-size:12.5px;color:#9B9EA3;margin-top:8px;line-height:1.55\"\u003eTotal head in feet. The shut-off and flow columns are read from the Grundfos 60 Hz curves for the 10 SQ, SQE (SQ and SQE share one curve, the SQE at its 10,700 rpm top speed), digitized from the published curve charts in the Grundfos SQ, SQE, SmartFlo and SP data booklet, at the nearest published point and rounded down. The (Rated) column is the head Grundfos prints at 10 GPM in its system sizing matrix, verbatim; the number in the model name is a nominal figure and reads lower on some models. 1 ft of head = 0.433 PSI. Full curves are in the product images and on the Data Sheet tab.\u003c\/p\u003e\n\u003cp style=\"font-size:13.5px;margin-bottom:10px;margin-top:18px\"\u003e\u003cstrong\u003eWhat It Delivers at Your Set Pressure\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdetails open style=\"margin:8px 0;border-top:3px solid #B3122A;padding:0 4px 6px\"\u003e\u003csummary style=\"cursor:pointer;padding:8px 0;font-weight:bold;color:#4A4A4F\"\u003eOutput at 50 and 60 PSI · 1\/2 to 1 HP · 4 models · depths 20 to 300 ft\u003c\/summary\u003e\n\u003cp\u003e\u003cstrong\u003eGPM at 50 PSI\u003c\/strong\u003e (CU 302 factory setpoint), by depth to water\u003c\/p\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003cth\u003e20 ft\u003c\/th\u003e\n\u003cth\u003e60 ft\u003c\/th\u003e\n\u003cth\u003e120 ft\u003c\/th\u003e\n\u003cth\u003e160 ft\u003c\/th\u003e\n\u003cth\u003e200 ft\u003c\/th\u003e\n\u003cth\u003e260 ft\u003c\/th\u003e\n\u003cth\u003e300 ft\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e10 SQE05-160\u003c\/td\u003e\n\u003ctd\u003e11.8\u003c\/td\u003e\n\u003ctd\u003e9\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e10 SQE07-200\u003c\/td\u003e\n\u003ctd\u003e13.5\u003c\/td\u003e\n\u003ctd\u003e11.9\u003c\/td\u003e\n\u003ctd\u003e8.8\u003c\/td\u003e\n\u003ctd\u003e4.4\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e10 SQE07-240\u003c\/td\u003e\n\u003ctd\u003e14.4\u003c\/td\u003e\n\u003ctd\u003e13.3\u003c\/td\u003e\n\u003ctd\u003e11.4\u003c\/td\u003e\n\u003ctd\u003e9.6\u003c\/td\u003e\n\u003ctd\u003e7.2\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e10 SQE10-290\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e14.2\u003c\/td\u003e\n\u003ctd\u003e12.9\u003c\/td\u003e\n\u003ctd\u003e11.8\u003c\/td\u003e\n\u003ctd\u003e10.5\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003ctd\u003e5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp\u003e\u003cstrong\u003eGPM at 60 PSI\u003c\/strong\u003e (setpoint), by depth to water\u003c\/p\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003cth\u003e20 ft\u003c\/th\u003e\n\u003cth\u003e60 ft\u003c\/th\u003e\n\u003cth\u003e120 ft\u003c\/th\u003e\n\u003cth\u003e160 ft\u003c\/th\u003e\n\u003cth\u003e200 ft\u003c\/th\u003e\n\u003cth\u003e260 ft\u003c\/th\u003e\n\u003cth\u003e300 ft\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e10 SQE05-160\u003c\/td\u003e\n\u003ctd\u003e10.5\u003c\/td\u003e\n\u003ctd\u003e6.2\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e10 SQE07-200\u003c\/td\u003e\n\u003ctd\u003e12.6\u003c\/td\u003e\n\u003ctd\u003e10.9\u003c\/td\u003e\n\u003ctd\u003e6.7\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e10 SQE07-240\u003c\/td\u003e\n\u003ctd\u003e13.8\u003c\/td\u003e\n\u003ctd\u003e12.6\u003c\/td\u003e\n\u003ctd\u003e10.5\u003c\/td\u003e\n\u003ctd\u003e8.4\u003c\/td\u003e\n\u003ctd\u003e5.3\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e10 SQE10-290\u003c\/td\u003e\n\u003ctd\u003e14.5\u003c\/td\u003e\n\u003ctd\u003e13.7\u003c\/td\u003e\n\u003ctd\u003e12.2\u003c\/td\u003e\n\u003ctd\u003e11\u003c\/td\u003e\n\u003ctd\u003e9.6\u003c\/td\u003e\n\u003ctd\u003e6.4\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails style=\"margin:8px 0;border-top:3px solid #B3122A;padding:0 4px 6px\"\u003e\u003csummary style=\"cursor:pointer;padding:8px 0;font-weight:bold;color:#4A4A4F\"\u003eOutput at 50 and 60 PSI · 1-1\/2 HP · 2 models · depths 40 to 400 ft\u003c\/summary\u003e\n\u003cp\u003e\u003cstrong\u003eGPM at 50 PSI\u003c\/strong\u003e (CU 302 factory setpoint), by depth to water\u003c\/p\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003cth\u003e40 ft\u003c\/th\u003e\n\u003cth\u003e80 ft\u003c\/th\u003e\n\u003cth\u003e140 ft\u003c\/th\u003e\n\u003cth\u003e200 ft\u003c\/th\u003e\n\u003cth\u003e240 ft\u003c\/th\u003e\n\u003cth\u003e280 ft\u003c\/th\u003e\n\u003cth\u003e400 ft\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e10 SQE15-330\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e14.4\u003c\/td\u003e\n\u003ctd\u003e13.3\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003ctd\u003e11.1\u003c\/td\u003e\n\u003ctd\u003e9.9\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e10 SQE15-370*\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e14.5\u003c\/td\u003e\n\u003ctd\u003e13.5\u003c\/td\u003e\n\u003ctd\u003e12.5\u003c\/td\u003e\n\u003ctd\u003e11.5\u003c\/td\u003e\n\u003ctd\u003e10.5\u003c\/td\u003e\n\u003ctd\u003e6.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp\u003e\u003cstrong\u003eGPM at 60 PSI\u003c\/strong\u003e (setpoint), by depth to water\u003c\/p\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003cth\u003e40 ft\u003c\/th\u003e\n\u003cth\u003e80 ft\u003c\/th\u003e\n\u003cth\u003e140 ft\u003c\/th\u003e\n\u003cth\u003e200 ft\u003c\/th\u003e\n\u003cth\u003e240 ft\u003c\/th\u003e\n\u003cth\u003e280 ft\u003c\/th\u003e\n\u003cth\u003e400 ft\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e10 SQE15-330\u003c\/td\u003e\n\u003ctd\u003e14.7\u003c\/td\u003e\n\u003ctd\u003e14\u003c\/td\u003e\n\u003ctd\u003e12.9\u003c\/td\u003e\n\u003ctd\u003e11.4\u003c\/td\u003e\n\u003ctd\u003e10.5\u003c\/td\u003e\n\u003ctd\u003e9\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e10 SQE15-370*\u003c\/td\u003e\n\u003ctd\u003e14.5\u003c\/td\u003e\n\u003ctd\u003e14\u003c\/td\u003e\n\u003ctd\u003e13\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003ctd\u003e11\u003c\/td\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003ctd\u003e5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cp style=\"font-size:12.5px;color:#9B9EA3;margin-top:8px;line-height:1.55\"\u003eFrom the Grundfos 3 in SQ sizing charts (pp. 38-39), verbatim: gallons per minute at the pressure shown and the depth to pumping water level. The SQE runs on the same curve as the SQ at full speed, so each cell is the most the SQE delivers while the CU 302 holds that pressure. Riser and pipe friction are not included. A dash means Grundfos prints no figure: on the shallow side the flow is past the chart range, on the deep side the pump cannot hold that pressure. Not shown: 10 SQE05-110, which Grundfos charts below 50 PSI at every depth; use them on a lower setpoint or for transfer duty. * 10 SQE15-370: Grundfos prints no sizing chart for this model, so its row is calculated, not printed: the flow where the published curve meets the depth plus 116 ft (50 PSI) or 139 ft (60 PSI), interpolated between published points and rounded down to 0.5 GPM.\u003c\/p\u003e\n\u003cp style=\"font-size:13.5px;margin-bottom:10px;margin-top:18px\"\u003e\u003cstrong\u003eDrop Cable Size\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdetails style=\"margin:8px 0;border-top:3px solid #B3122A;padding:0 4px 6px\"\u003e\u003csummary style=\"cursor:pointer;padding:8px 0;font-weight:bold;color:#4A4A4F\"\u003eDrop cable size by distance · copper, 60 Hz\u003c\/summary\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eVolts\u003c\/th\u003e\n\u003cth\u003eHP\u003c\/th\u003e\n\u003cth\u003eAmps\u003c\/th\u003e\n\u003cth\u003e14 AWG\u003c\/th\u003e\n\u003cth\u003e12 AWG\u003c\/th\u003e\n\u003cth\u003e10 AWG\u003c\/th\u003e\n\u003cth\u003e8 AWG\u003c\/th\u003e\n\u003cth\u003e6 AWG\u003c\/th\u003e\n\u003cth\u003e4 AWG\u003c\/th\u003e\n\u003cth\u003e2 AWG\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e115\u003c\/td\u003e\n\u003ctd\u003e1\/2\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003ctd\u003e140\u003c\/td\u003e\n\u003ctd\u003e220\u003c\/td\u003e\n\u003ctd\u003e360\u003c\/td\u003e\n\u003ctd\u003e550\u003c\/td\u003e\n\u003ctd\u003e880\u003c\/td\u003e\n\u003ctd\u003e1390\u003c\/td\u003e\n\u003ctd\u003e2260\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e230\u003c\/td\u003e\n\u003ctd\u003e1\/2\u003c\/td\u003e\n\u003ctd\u003e5.2\u003c\/td\u003e\n\u003ctd\u003e640\u003c\/td\u003e\n\u003ctd\u003e1000\u003c\/td\u003e\n\u003ctd\u003e1660\u003c\/td\u003e\n\u003ctd\u003e2250\u003c\/td\u003e\n\u003ctd\u003e4060\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e230\u003c\/td\u003e\n\u003ctd\u003e3\/4\u003c\/td\u003e\n\u003ctd\u003e8.4\u003c\/td\u003e\n\u003ctd\u003e400\u003c\/td\u003e\n\u003ctd\u003e620\u003c\/td\u003e\n\u003ctd\u003e1030\u003c\/td\u003e\n\u003ctd\u003e1580\u003c\/td\u003e\n\u003ctd\u003e2510\u003c\/td\u003e\n\u003ctd\u003e3970\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e230\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003ctd\u003e11.2\u003c\/td\u003e\n\u003ctd\u003e300\u003c\/td\u003e\n\u003ctd\u003e460\u003c\/td\u003e\n\u003ctd\u003e770\u003c\/td\u003e\n\u003ctd\u003e1190\u003c\/td\u003e\n\u003ctd\u003e1890\u003c\/td\u003e\n\u003ctd\u003e2980\u003c\/td\u003e\n\u003ctd\u003e4850\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e230\u003c\/td\u003e\n\u003ctd\u003e1-1\/2\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003ctd\u003e280\u003c\/td\u003e\n\u003ctd\u003e430\u003c\/td\u003e\n\u003ctd\u003e720\u003c\/td\u003e\n\u003ctd\u003e1110\u003c\/td\u003e\n\u003ctd\u003e1760\u003c\/td\u003e\n\u003ctd\u003e2780\u003c\/td\u003e\n\u003ctd\u003e4530\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"font-size:12.5px;color:#9B9EA3;margin-top:8px;line-height:1.55\"\u003eMaximum length in feet from the motor to the service entrance, copper wire, 9% voltage drop, from the Grundfos SQ, SQE installation and operating instructions and data booklet. A dash means not listed.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdiv style=\"display:flex;flex-wrap:wrap;gap:10px;margin:22px 0 4px\"\u003e\n\u003ca href=\"\/pages\/submersible-well-pump-sizing-calculator\" style=\"flex:1 1 200px;text-align:center;display:block;background:#B3122A;color:#ffffff;font-family:Arial Black,Arial,sans-serif;font-size:12px;text-transform:uppercase;letter-spacing:1.2px;padding:11px 18px;text-decoration:none\"\u003eSubmersible Calculator\u003c\/a\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eBefore You Buy — The Limits That Decide the Fit\u003c\/div\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eCheck\u003c\/th\u003e\n\u003cth\u003eWhat to confirm\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eWell size\u003c\/td\u003e\n\u003ctd\u003e3 in or larger casing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWater\u003c\/td\u003e\n\u003ctd\u003eClean water, pH 5 to 9, up to 86°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSetting\u003c\/td\u003e\n\u003ctd\u003eNo deeper than 500 ft below the static water level, and at least 20 in below the pumping water level\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower\u003c\/td\u003e\n\u003ctd\u003e1\/2 HP models come in 115 V or 230 V versions (different part numbers, not field-convertible); 3\/4 HP and up are 230 V only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWiring\u003c\/td\u003e\n\u003ctd\u003eCU 302 for constant pressure; or a pressure switch rated for the pump's current. Never a capacitor, control box or external drive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHorizontal install\u003c\/td\u003e\n\u003ctd\u003eUse the SQ\/SQE flow sleeve (on our \u003ca href=\"\/products\/grundfos-sq-sqe-pump-accessories\"\u003eGrundfos SQ and SQE Pump Accessories\u003c\/a\u003e listing) to keep water moving past the motor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGenerator\u003c\/td\u003e\n\u003ctd\u003eAt least the motor input power plus 50% (minimum plus 10%)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eMaterials of Construction\u003c\/div\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003ePart\u003c\/th\u003e\n\u003cth\u003eMaterial\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePump sleeve, outlet chamber, cable guard\u003c\/td\u003e\n\u003ctd\u003eAISI 304 stainless steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eImpellers, chambers, guide vanes, valve casing\u003c\/td\u003e\n\u003ctd\u003ePolyamide (30% glass-fibre reinforced)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eImpeller bearings\u003c\/td\u003e\n\u003ctd\u003eTungsten carbide \/ ceramic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShaft\u003c\/td\u003e\n\u003ctd\u003eAISI 304 stainless steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eValve seat, seals\u003c\/td\u003e\n\u003ctd\u003eNBR rubber\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor stator, rotor, top cover\u003c\/td\u003e\n\u003ctd\u003eAISI 304 stainless steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor bearings\u003c\/td\u003e\n\u003ctd\u003eSilicon carbide \/ tungsten carbide (coated); carbon thrust bearing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"font-size:12.5px;color:#9B9EA3;margin-top:8px;line-height:1.55\"\u003eSource: Grundfos SQ, SQE, SmartFlo and SP data booklet, construction.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"gs-contact\"\u003eFor engineering-led sizing and selection support or a factory submittal, email \u003ca href=\"mailto:sales@watermainsupply.com\"\u003esales@watermainsupply.com\u003c\/a\u003e or call \u003ca href=\"tel:18885104036\"\u003e1-888.510.4036\u003c\/a\u003e.\u003cbr\u003e© Watermain Supply — A division of E4 Industrial LLC\u003c\/div\u003e\n\n\u003c\/div\u003e\n\u003ch5\u003eData Sheet\u003c\/h5\u003e\u003cdiv class=\"gs\"\u003e\u003cdiv class=\"gs-dl\"\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0264\/1913\/4527\/files\/SQ_SQE_us.pdf?v=1788826864\" target=\"_blank\" rel=\"noopener\"\u003eSQ, SQE Installation and Operating Instructions\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0264\/1913\/4527\/files\/SQE_Brochure_2.pdf?v=1788826864\" target=\"_blank\" rel=\"noopener\"\u003eGrundfos SQE Constant Pressure Groundwater System Brochure\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0264\/1913\/4527\/files\/SQ_SQE_Brochure.pdf?v=1788826865\" target=\"_blank\" rel=\"noopener\"\u003eGrundfos SQ\/SQE Range Brochure\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0264\/1913\/4527\/files\/SQ_Performance_Curves.pdf?v=1788826864\" target=\"_blank\" rel=\"noopener\"\u003e3 in SQ Sizing Guide — Curves and Sizing Charts\u003c\/a\u003e\n\u003c\/div\u003e\u003c\/div\u003e\u003ch5\u003eVideos\u003c\/h5\u003e\u003cdiv class=\"gs\"\u003e\u003cdiv class=\"gs-sec\" style=\"margin-top:6px\"\u003e\n\u003cdiv style=\"display:grid;grid-template-columns:repeat(auto-fit,minmax(300px,1fr));gap:20px\"\u003e\n\u003cdiv\u003e\n\u003cdiv style=\"position:relative;width:100%;padding-top:56.25%;background:#4A4A4F\"\u003e\u003ciframe src=\"https:\/\/www.youtube.com\/embed\/_Kn3OVDRZOE?si=3DToNwIsKFSrV9Bt\" title=\"SQ and SQE: Constant Pressure Pump Overview\" loading=\"lazy\" frameborder=\"0\" style=\"position:absolute;top:0;left:0;width:100%;height:100%;border:0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share\" referrerpolicy=\"strict-origin-when-cross-origin\" allowfullscreen\u003e\u003c\/iframe\u003e\u003c\/div\u003e\n\u003cp style=\"font-family:Arial,Helvetica,sans-serif;font-size:13px;line-height:1.45;color:#4A4A4F;margin:8px 0 0\"\u003eSQ and SQE: Constant Pressure Pump Overview \u003cspan style=\"color:#9B9EA3\"\u003e(4:02)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cdiv style=\"position:relative;width:100%;padding-top:56.25%;background:#4A4A4F\"\u003e\u003ciframe src=\"https:\/\/www.youtube.com\/embed\/lHPdSndKQqs?si=tktPTsRHA2Z-H07V\" title=\"Installing a Grundfos SQE Constant Pressure System\" loading=\"lazy\" frameborder=\"0\" style=\"position:absolute;top:0;left:0;width:100%;height:100%;border:0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share\" referrerpolicy=\"strict-origin-when-cross-origin\" allowfullscreen\u003e\u003c\/iframe\u003e\u003c\/div\u003e\n\u003cp style=\"font-family:Arial,Helvetica,sans-serif;font-size:13px;line-height:1.45;color:#4A4A4F;margin:8px 0 0\"\u003eInstalling a Grundfos SQE Constant Pressure System \u003cspan style=\"color:#9B9EA3\"\u003e(5:22)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cdiv style=\"position:relative;width:100%;padding-top:56.25%;background:#4A4A4F\"\u003e\u003ciframe src=\"https:\/\/www.youtube.com\/embed\/U4gomM0GLr0?si=CP3NowIBbbzTzjEP\" title=\"Grundfos SQE Pump Restores Clean Water to a California Family\" loading=\"lazy\" frameborder=\"0\" style=\"position:absolute;top:0;left:0;width:100%;height:100%;border:0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share\" referrerpolicy=\"strict-origin-when-cross-origin\" allowfullscreen\u003e\u003c\/iframe\u003e\u003c\/div\u003e\n\u003cp style=\"font-family:Arial,Helvetica,sans-serif;font-size:13px;line-height:1.45;color:#4A4A4F;margin:8px 0 0\"\u003eGrundfos SQE Pump Restores Clean Water to a California Family \u003cspan style=\"color:#9B9EA3\"\u003e(6:42)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp style=\"font-family:Arial,Helvetica,sans-serif;font-size:12px;color:#9B9EA3;margin:16px 0 0\"\u003eVideos produced by Grundfos and hosted on YouTube.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/div\u003e\u003ch5\u003eGrundfos HOME App\u003c\/h5\u003e\u003cdiv class=\"gs\"\u003e\u003cdiv class=\"gs-sec\" style=\"margin-top:6px\"\u003e\n\u003cdiv class=\"gs-h\"\u003eSet Up \u0026amp; Monitor From Your Phone\u003c\/div\u003e\n\u003cdiv class=\"gs-lead\"\u003e\u003cp\u003eThe free Grundfos HOME app gives you full control of your water system from an iOS or Android phone. Pair an SQE with a CU 302 control unit and the app reports pump information around the clock, sends alert notifications on important events so you can act before the water goes off, and carries a built-in watering calendar with an internal clock so irrigation routines run to schedule without a timer. Installer details are stored in the app, so whoever set the system up is one tap away.\u003c\/p\u003e\u003c\/div\u003e\n\u003cdiv style=\"margin-top:16px\"\u003e\n\u003ca href=\"https:\/\/apps.apple.com\/us\/app\/grundfos-home\/id1592451846\" target=\"_blank\" rel=\"noopener\" style=\"display:inline-block;background:#B3122A;color:#fff!important;font-family:Arial Black,Arial,sans-serif;font-size:13px;letter-spacing:1px;text-transform:uppercase;text-decoration:none;padding:12px 24px;border-radius:999px;margin:0 10px 10px 0\"\u003eDownload for iOS\u003c\/a\u003e\u003ca href=\"https:\/\/play.google.com\/store\/apps\/details?id=com.grundfos.home\u0026amp;pcampaignid=web_share\" target=\"_blank\" rel=\"noopener\" style=\"display:inline-block;background:#4A4A4F;color:#fff!important;font-family:Arial Black,Arial,sans-serif;font-size:13px;letter-spacing:1px;text-transform:uppercase;text-decoration:none;padding:12px 24px;border-radius:999px;margin:0 10px 10px 0\"\u003eDownload for Android\u003c\/a\u003e\n\u003c\/div\u003e\n\u003cp style=\"font-size:12px;color:#9B9EA3;margin-top:14px;line-height:1.6\"\u003eGrundfos HOME is a free app from Grundfos Holding A\/S. It connects through the CU 302 control unit, which is required and is sold separately, and Bluetooth must be enabled on the CU 302 operating panel before pairing. Installers and service technicians use a separate free Grundfos app, Grundfos GO, as the commissioning and diagnostic tool; ask us for the link if you need it.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/div\u003e\u003c!-- \/TABS --\u003e","brand":"Grundfos","offers":[{"title":"1\/2 HP - 3 in Motor \/ 115V 1Ph 2-Wire \/ 10 SQE05-110 - 105 ft at 10 GPM","offer_id":47457479557295,"sku":"96160209","price":1292.81,"currency_code":"USD","in_stock":true},{"title":"1\/2 HP - 3 in Motor \/ 115V 1Ph 2-Wire \/ 10 SQE05-160 - 164 ft at 10 GPM","offer_id":47457479590063,"sku":"96160210","price":1297.2,"currency_code":"USD","in_stock":true},{"title":"1\/2 HP - 3 in Motor \/ 230V 1Ph 2-Wire \/ 10 SQE05-110 - 105 ft at 10 GPM","offer_id":47457479622831,"sku":"96160182","price":1292.81,"currency_code":"USD","in_stock":true},{"title":"1\/2 HP - 3 in Motor \/ 230V 1Ph 2-Wire \/ 10 SQE05-160 - 164 ft at 10 GPM","offer_id":47457479655599,"sku":"96160183","price":1297.2,"currency_code":"USD","in_stock":true},{"title":"3\/4 HP - 3 in Motor \/ 230V 1Ph 2-Wire \/ 10 SQE07-200 - 215 ft at 10 GPM","offer_id":47457479688367,"sku":"96160184","price":1544.11,"currency_code":"USD","in_stock":true},{"title":"3\/4 HP - 3 in Motor \/ 230V 1Ph 2-Wire \/ 10 SQE07-240 - 267 ft at 10 GPM","offer_id":47457479721135,"sku":"96160185","price":1619.31,"currency_code":"USD","in_stock":true},{"title":"1 HP - 3 in Motor \/ 230V 1Ph 2-Wire \/ 10 SQE10-290 - 328 ft at 10 GPM","offer_id":47457479753903,"sku":"96160186","price":1774.09,"currency_code":"USD","in_stock":true},{"title":"1-1\/2 HP - 3 in Motor \/ 230V 1Ph 2-Wire \/ 10 SQE15-330 - 390 ft at 10 GPM","offer_id":47457479786671,"sku":"96160187","price":1813.57,"currency_code":"USD","in_stock":true},{"title":"1-1\/2 HP - 3 in Motor \/ 230V 1Ph 2-Wire \/ 10 SQE15-370 - 434 ft at 10 GPM","offer_id":47457479819439,"sku":"93001328","price":1883.13,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0264\/1913\/4527\/files\/Grundfos_SQE_Submersible_Pump.webp?v=1788826893"},{"product_id":"grundfos-15-sqe-submersible-well-pump","title":"Grundfos 15 SQE Submersible Well Pump","description":"\u003c!-- TABS --\u003e\n\u003ch5\u003eDescription\u003c\/h5\u003e\n\u003cdiv class=\"gs\"\u003e\n\n\u003cdiv class=\"gs-head\"\u003e\n\u003cdiv class=\"gs-eyebrow\"\u003eGrundfos · 3 in Submersible Well Pump\u003c\/div\u003e\n\u003cdiv class=\"gs-title\"\u003e15 SQE\u003c\/div\u003e\n\u003cdiv class=\"gs-sub\"\u003eNominal 15 GPM 3 in constant-pressure submersible well pump with a permanent-magnet motor and built-in protection: 8 models from 1\/2 to 1-1\/2 HP, 75-355 ft of head at 15 GPM, 1-1\/4 in NPT discharge. Runs on a CU 302 for constant pressure.\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"gs-badges\"\u003e\n\u003cdiv class=\"gs-badge\" style=\"background:#B3122A;color:#FFFFFF;border-color:#B3122A\"\u003e15 GPM Rated Flow\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003e1\/2 to 1-1\/2 HP\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003e75-355 ft at 15 GPM\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003e4-20 GPM Flow Range\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003eConstant Pressure with CU 302\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003e3 in Min. Well\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003e1-1\/4 in NPT Discharge\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003e115V or 230V 1Ph\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003eDry-Run, Voltage and Overload Protection\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003e2.9 in Dia x 29.1-37.0 in L\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003e11-16 lb Ship Weight\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eOverview\u003c\/div\u003e\n\u003cdiv class=\"gs-lead\"\u003e\n\u003cp\u003eThe Grundfos 15 SQE is a 3 in stainless steel well pump with a variable-speed permanent-magnet \"Smart Motor\". Paired with a \u003ca href=\"\/products\/grundfos-cu-302-constant-pressure-control\"\u003eGrundfos CU 302 Constant Pressure Control\u003c\/a\u003e, it holds the pressure you set, from a trickle at one tap to full flow, instead of cycling between a pressure switch's cut-in and cut-out. The CU 302 talks to the pump over the power leads, so no extra wires go down the well, and it pairs with the Grundfos GO and HOME apps by Bluetooth.\u003c\/p\u003e\n\u003cp\u003eIt is rated at 15 GPM, with 8 models from 1\/2 to 1-1\/2 HP for deeper settings. The pump fits a 3 in or larger well and suits household supply, light commercial service, irrigation and tank filling or emptying.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eConstant pressure.\u003c\/strong\u003e The CU 302 changes pump speed, 3,000 to 10,700 rpm, to hold its setpoint (factory 50 PSI, adjustable 20 to 100 PSI in 5 PSI steps). It works with a 2 gal diaphragm tank instead of a large pressure tank.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBuilt-in protection.\u003c\/strong\u003e Dry-run, over- and undervoltage (cuts out below 150 V and above 315 V and restarts by itself), overload, locked-rotor and over-temperature protection are built into the motor. No protection relay or motor starter needed.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSoft start, no start limit.\u003c\/strong\u003e The motor ramps up in about 3 seconds and has no limit on starts or stops per hour.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSand-tolerant hydraulics.\u003c\/strong\u003e Floating impellers each run on their own tungsten carbide \/ ceramic bearing; a top bearing protects pump and motor against upthrust at start-up.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall it any way up.\u003c\/strong\u003e Vertical, horizontal or anywhere between, with a built-in spring check valve; use a flow sleeve when horizontal.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"background:#FFFFFF;border:1px solid #C7CBD1;border-top:3px solid #B3122A;padding:12px 16px 12px;margin:16px 0 4px;font-size:13.5px;line-height:1.55;color:#4A4A4F\"\u003e\n\u003cdiv style=\"font-family:Arial Black,Arial,sans-serif;font-size:11px;letter-spacing:1.2px;text-transform:uppercase;color:#B3122A;margin-bottom:8px\"\u003eWhat Ships and What It Needs to Run\u003c\/div\u003e\n\u003cp style=\"margin:0 0 6px\"\u003e\u003cstrong style=\"color:#B3122A\"\u003eIncluded:\u003c\/strong\u003e the pump and its 3 in SQE motor, assembled, with a built-in check valve, plus a 5 ft, 14 AWG motor cable with plug that you press onto the motor socket and secure with four screws. The controller is \u003cstrong\u003enot\u003c\/strong\u003e in the box.\u003c\/p\u003e\n\u003cp style=\"margin:0 0 6px\"\u003e\u003cstrong style=\"color:#B3122A\"\u003eFor constant pressure: CU 302 and a pressure sensor, ordered separately.\u003c\/strong\u003e Use the \u003ca href=\"\/products\/grundfos-cu-302-constant-pressure-control\"\u003eGrundfos CU 302 Constant Pressure Control\u003c\/a\u003e, sold with or without its 0-120 PSI pressure sensor, plus a 2 gal diaphragm tank. Variable speed needs the CU 302.\u003c\/p\u003e\n\u003cp style=\"margin:0 0 6px\"\u003e\u003cstrong style=\"color:#B3122A\"\u003eWithout a controller:\u003c\/strong\u003e Grundfos states the motor can be connected directly to the main breaker and started by a pressure switch rated for the pump's current; it then runs at full speed, like an SQ, with no constant pressure.\u003c\/p\u003e\n\u003cp style=\"margin:0 0 6px\"\u003e\u003cstrong style=\"color:#B3122A\"\u003eNever connect:\u003c\/strong\u003e a capacitor, a conventional control box or an external frequency drive.\u003c\/p\u003e\n\u003cp style=\"margin:0\"\u003e\u003cstrong style=\"color:#B3122A\"\u003eDrop cable and splice kit:\u003c\/strong\u003e sized to your setting depth (cable table under Models \u0026amp; Performance) and ordered separately. A replacement motor cable is on our \u003ca href=\"\/products\/grundfos-sq-sqe-pump-accessories\"\u003eGrundfos SQ and SQE Pump Accessories\u003c\/a\u003e listing; you do not need one for a new pump.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"background:#E1E3E6;border-left:3px solid #B8BDC4;padding:8px 14px;font-size:11.5px;color:#4A4A4F;margin-top:14px;line-height:1.5\"\u003eGenuine Grundfos equipment, factory-new in original packaging — sold and supported by Watermain Supply, an independent industrial supplier.\u003c\/div\u003e\n\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eWarranty\u003c\/div\u003e\n\u003cdiv class=\"gs-lead\"\u003e\u003cp\u003e24 months from date of installation, but not more than 30 months from date of manufacture. In Grundfos's words, products are “warranted to the original user only to be free of defects in material and workmanship”; the full terms are in the installation and operating instructions on the Data Sheet tab.\u003c\/p\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eSpecifications\u003c\/div\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated flow\u003c\/td\u003e\n\u003ctd\u003e15 GPM nominal; working range 4-20 GPM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHorsepower\u003c\/td\u003e\n\u003ctd\u003e1\/2 to 1-1\/2 HP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply\u003c\/td\u003e\n\u003ctd\u003e1 x 100-115 V (1\/2 HP only) or 1 x 200-240 V, 60 Hz; 2-wire plus ground\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor\u003c\/td\u003e\n\u003ctd\u003eMSE 3 permanent-magnet motor with built-in electronics, 3,000 to 10,700 rpm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl\u003c\/td\u003e\n\u003ctd\u003eCU 302 over the power leads (GENIbus); Bluetooth to Grundfos GO and the Grundfos HOME app\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection\u003c\/td\u003e\n\u003ctd\u003eDry run, overvoltage and undervoltage (cuts out below 150 V and above 315 V), overload, locked rotor, over-temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStarting\u003c\/td\u003e\n\u003ctd\u003eSoft start, run-up maximum 3 seconds; no limit on starts or stops per hour\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor cable\u003c\/td\u003e\n\u003ctd\u003e3-wire, 14 AWG XLPE, 5 ft, with plug\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDischarge\u003c\/td\u003e\n\u003ctd\u003e1-1\/4 in NPT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWell diameter\u003c\/td\u003e\n\u003ctd\u003e3 in minimum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSetting depth\u003c\/td\u003e\n\u003ctd\u003eUp to 500 ft below the static water level; at least 20 in below the pumping water level\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePumped liquid\u003c\/td\u003e\n\u003ctd\u003eClean water, pH 5 to 9, up to 86°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGenerator\u003c\/td\u003e\n\u003ctd\u003eOutput at least the motor input power (P1) plus 50% recommended, never less than P1 plus 10%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"font-size:12.5px;color:#9B9EA3;margin-top:8px;line-height:1.55\"\u003eSource: Grundfos SQ, SQE, SmartFlo and SP data booklet (North America, 60 Hz), technical data.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eModels \u0026amp; Performance — Will It Do What You Need?\u003c\/div\u003e\n\u003cp style=\"font-size:13.5px;margin-bottom:10px\"\u003ePick a model whose head at your flow covers the pumping water level, the pressure you need at the surface (2.31 ft per PSI) and pipe friction. Then check the set-pressure table for what it delivers at your depth.\u003c\/p\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003cth\u003eHP\u003c\/th\u003e\n\u003cth\u003e0 GPM (Shut-off)\u003c\/th\u003e\n\u003cth\u003e3.9 GPM\u003c\/th\u003e\n\u003cth\u003e9.7 GPM\u003c\/th\u003e\n\u003cth\u003e15 GPM (Rated)\u003c\/th\u003e\n\u003cth\u003e19.3 GPM (Max)\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e15 SQE05-70\u003c\/td\u003e\n\u003ctd\u003e1\/2\u003c\/td\u003e\n\u003ctd\u003e117\u003c\/td\u003e\n\u003ctd\u003e114\u003c\/td\u003e\n\u003ctd\u003e104\u003c\/td\u003e\n\u003ctd\u003e75\u003c\/td\u003e\n\u003ctd\u003e43\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e15 SQE05-110\u003c\/td\u003e\n\u003ctd\u003e1\/2\u003c\/td\u003e\n\u003ctd\u003e183\u003c\/td\u003e\n\u003ctd\u003e179\u003c\/td\u003e\n\u003ctd\u003e164\u003c\/td\u003e\n\u003ctd\u003e123\u003c\/td\u003e\n\u003ctd\u003e68\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e15 SQE07-150\u003c\/td\u003e\n\u003ctd\u003e3\/4\u003c\/td\u003e\n\u003ctd\u003e242\u003c\/td\u003e\n\u003ctd\u003e237\u003c\/td\u003e\n\u003ctd\u003e216\u003c\/td\u003e\n\u003ctd\u003e164\u003c\/td\u003e\n\u003ctd\u003e94\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e15 SQE07-180\u003c\/td\u003e\n\u003ctd\u003e3\/4\u003c\/td\u003e\n\u003ctd\u003e300\u003c\/td\u003e\n\u003ctd\u003e296\u003c\/td\u003e\n\u003ctd\u003e269\u003c\/td\u003e\n\u003ctd\u003e205\u003c\/td\u003e\n\u003ctd\u003e118\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e15 SQE10-220\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003ctd\u003e361\u003c\/td\u003e\n\u003ctd\u003e355\u003c\/td\u003e\n\u003ctd\u003e323\u003c\/td\u003e\n\u003ctd\u003e246\u003c\/td\u003e\n\u003ctd\u003e141\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e15 SQE10-250\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003ctd\u003e421\u003c\/td\u003e\n\u003ctd\u003e415\u003c\/td\u003e\n\u003ctd\u003e376\u003c\/td\u003e\n\u003ctd\u003e287\u003c\/td\u003e\n\u003ctd\u003e164\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e15 SQE15-290\u003c\/td\u003e\n\u003ctd\u003e1-1\/2\u003c\/td\u003e\n\u003ctd\u003e481\u003c\/td\u003e\n\u003ctd\u003e474\u003c\/td\u003e\n\u003ctd\u003e430\u003c\/td\u003e\n\u003ctd\u003e328\u003c\/td\u003e\n\u003ctd\u003e186\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e15 SQE15-330\u003c\/td\u003e\n\u003ctd\u003e1-1\/2\u003c\/td\u003e\n\u003ctd\u003e525\u003c\/td\u003e\n\u003ctd\u003e517\u003c\/td\u003e\n\u003ctd\u003e470\u003c\/td\u003e\n\u003ctd\u003e355\u003c\/td\u003e\n\u003ctd\u003e203\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"font-size:12.5px;color:#9B9EA3;margin-top:8px;line-height:1.55\"\u003eTotal head in feet. The shut-off and flow columns are read from the Grundfos 60 Hz curves for the 15 SQ, SQE (SQ and SQE share one curve, the SQE at its 10,700 rpm top speed), digitized from the published curve charts in the Grundfos SQ, SQE, SmartFlo and SP data booklet, at the nearest published point and rounded down. The (Rated) column is the head Grundfos prints at 15 GPM in its system sizing matrix, verbatim; the number in the model name is a nominal figure and reads lower on some models. 1 ft of head = 0.433 PSI. Full curves are in the product images and on the Data Sheet tab.\u003c\/p\u003e\n\u003cp style=\"font-size:13.5px;margin-bottom:10px;margin-top:18px\"\u003e\u003cstrong\u003eWhat It Delivers at Your Set Pressure\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdetails open style=\"margin:8px 0;border-top:3px solid #B3122A;padding:0 4px 6px\"\u003e\u003csummary style=\"cursor:pointer;padding:8px 0;font-weight:bold;color:#4A4A4F\"\u003eOutput at 50 and 60 PSI · 1\/2 to 1 HP · 5 models · depths 20 to 300 ft\u003c\/summary\u003e\n\u003cp\u003e\u003cstrong\u003eGPM at 50 PSI\u003c\/strong\u003e (CU 302 factory setpoint), by depth to water\u003c\/p\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003cth\u003e20 ft\u003c\/th\u003e\n\u003cth\u003e60 ft\u003c\/th\u003e\n\u003cth\u003e120 ft\u003c\/th\u003e\n\u003cth\u003e160 ft\u003c\/th\u003e\n\u003cth\u003e200 ft\u003c\/th\u003e\n\u003cth\u003e260 ft\u003c\/th\u003e\n\u003cth\u003e300 ft\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e15 SQE05-110\u003c\/td\u003e\n\u003ctd\u003e13.8\u003c\/td\u003e\n\u003ctd\u003e6.2\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e15 SQE07-150\u003c\/td\u003e\n\u003ctd\u003e17\u003c\/td\u003e\n\u003ctd\u003e14.1\u003c\/td\u003e\n\u003ctd\u003e4.8\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e15 SQE07-180\u003c\/td\u003e\n\u003ctd\u003e18.7\u003c\/td\u003e\n\u003ctd\u003e16.8\u003c\/td\u003e\n\u003ctd\u003e12.8\u003c\/td\u003e\n\u003ctd\u003e9\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e15 SQE10-220\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e18.1\u003c\/td\u003e\n\u003ctd\u003e15.7\u003c\/td\u003e\n\u003ctd\u003e13.4\u003c\/td\u003e\n\u003ctd\u003e10.3\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e15 SQE10-250\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e19\u003c\/td\u003e\n\u003ctd\u003e17.2\u003c\/td\u003e\n\u003ctd\u003e15.6\u003c\/td\u003e\n\u003ctd\u003e13.7\u003c\/td\u003e\n\u003ctd\u003e9.7\u003c\/td\u003e\n\u003ctd\u003e4.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp\u003e\u003cstrong\u003eGPM at 60 PSI\u003c\/strong\u003e (setpoint), by depth to water\u003c\/p\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003cth\u003e20 ft\u003c\/th\u003e\n\u003cth\u003e60 ft\u003c\/th\u003e\n\u003cth\u003e120 ft\u003c\/th\u003e\n\u003cth\u003e160 ft\u003c\/th\u003e\n\u003cth\u003e200 ft\u003c\/th\u003e\n\u003cth\u003e260 ft\u003c\/th\u003e\n\u003cth\u003e300 ft\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e15 SQE05-110\u003c\/td\u003e\n\u003ctd\u003e10.4\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e15 SQE07-150\u003c\/td\u003e\n\u003ctd\u003e15.4\u003c\/td\u003e\n\u003ctd\u003e11.9\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e15 SQE07-180\u003c\/td\u003e\n\u003ctd\u003e17.7\u003c\/td\u003e\n\u003ctd\u003e15.5\u003c\/td\u003e\n\u003ctd\u003e10.7\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e15 SQE10-220\u003c\/td\u003e\n\u003ctd\u003e18.9\u003c\/td\u003e\n\u003ctd\u003e17.3\u003c\/td\u003e\n\u003ctd\u003e14.4\u003c\/td\u003e\n\u003ctd\u003e11.9\u003c\/td\u003e\n\u003ctd\u003e7.7\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e15 SQE10-250\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e18.5\u003c\/td\u003e\n\u003ctd\u003e16.3\u003c\/td\u003e\n\u003ctd\u003e14.6\u003c\/td\u003e\n\u003ctd\u003e12.4\u003c\/td\u003e\n\u003ctd\u003e7.4\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails style=\"margin:8px 0;border-top:3px solid #B3122A;padding:0 4px 6px\"\u003e\u003csummary style=\"cursor:pointer;padding:8px 0;font-weight:bold;color:#4A4A4F\"\u003eOutput at 50 and 60 PSI · 1-1\/2 HP · 2 models · depths 60 to 400 ft\u003c\/summary\u003e\n\u003cp\u003e\u003cstrong\u003eGPM at 50 PSI\u003c\/strong\u003e (CU 302 factory setpoint), by depth to water\u003c\/p\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003cth\u003e60 ft\u003c\/th\u003e\n\u003cth\u003e100 ft\u003c\/th\u003e\n\u003cth\u003e160 ft\u003c\/th\u003e\n\u003cth\u003e200 ft\u003c\/th\u003e\n\u003cth\u003e240 ft\u003c\/th\u003e\n\u003cth\u003e300 ft\u003c\/th\u003e\n\u003cth\u003e400 ft\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e15 SQE15-290\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e18.7\u003c\/td\u003e\n\u003ctd\u003e17\u003c\/td\u003e\n\u003ctd\u003e15.6\u003c\/td\u003e\n\u003ctd\u003e14\u003c\/td\u003e\n\u003ctd\u003e10.9\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e15 SQE15-330*\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e19\u003c\/td\u003e\n\u003ctd\u003e17.5\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003ctd\u003e15\u003c\/td\u003e\n\u003ctd\u003e12.5\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp\u003e\u003cstrong\u003eGPM at 60 PSI\u003c\/strong\u003e (setpoint), by depth to water\u003c\/p\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003cth\u003e60 ft\u003c\/th\u003e\n\u003cth\u003e100 ft\u003c\/th\u003e\n\u003cth\u003e160 ft\u003c\/th\u003e\n\u003cth\u003e200 ft\u003c\/th\u003e\n\u003cth\u003e240 ft\u003c\/th\u003e\n\u003cth\u003e300 ft\u003c\/th\u003e\n\u003cth\u003e400 ft\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e15 SQE15-290\u003c\/td\u003e\n\u003ctd\u003e19.2\u003c\/td\u003e\n\u003ctd\u003e18.2\u003c\/td\u003e\n\u003ctd\u003e16.2\u003c\/td\u003e\n\u003ctd\u003e14.8\u003c\/td\u003e\n\u003ctd\u003e12.8\u003c\/td\u003e\n\u003ctd\u003e9.1\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e15 SQE15-330*\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e18.5\u003c\/td\u003e\n\u003ctd\u003e16.5\u003c\/td\u003e\n\u003ctd\u003e15.5\u003c\/td\u003e\n\u003ctd\u003e14\u003c\/td\u003e\n\u003ctd\u003e11.5\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cp style=\"font-size:12.5px;color:#9B9EA3;margin-top:8px;line-height:1.55\"\u003eFrom the Grundfos 3 in SQ sizing charts (pp. 40-41), verbatim: gallons per minute at the pressure shown and the depth to pumping water level. The SQE runs on the same curve as the SQ at full speed, so each cell is the most the SQE delivers while the CU 302 holds that pressure. Riser and pipe friction are not included. A dash means Grundfos prints no figure: on the shallow side the flow is past the chart range, on the deep side the pump cannot hold that pressure. Not shown: 15 SQE05-70, which Grundfos charts below 50 PSI at every depth; use them on a lower setpoint or for transfer duty. * 15 SQE15-330: Grundfos prints no sizing chart for this model, so its row is calculated, not printed: the flow where the published curve meets the depth plus 116 ft (50 PSI) or 139 ft (60 PSI), interpolated between published points and rounded down to 0.5 GPM.\u003c\/p\u003e\n\u003cp style=\"font-size:13.5px;margin-bottom:10px;margin-top:18px\"\u003e\u003cstrong\u003eDrop Cable Size\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdetails style=\"margin:8px 0;border-top:3px solid #B3122A;padding:0 4px 6px\"\u003e\u003csummary style=\"cursor:pointer;padding:8px 0;font-weight:bold;color:#4A4A4F\"\u003eDrop cable size by distance · copper, 60 Hz\u003c\/summary\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eVolts\u003c\/th\u003e\n\u003cth\u003eHP\u003c\/th\u003e\n\u003cth\u003eAmps\u003c\/th\u003e\n\u003cth\u003e14 AWG\u003c\/th\u003e\n\u003cth\u003e12 AWG\u003c\/th\u003e\n\u003cth\u003e10 AWG\u003c\/th\u003e\n\u003cth\u003e8 AWG\u003c\/th\u003e\n\u003cth\u003e6 AWG\u003c\/th\u003e\n\u003cth\u003e4 AWG\u003c\/th\u003e\n\u003cth\u003e2 AWG\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e115\u003c\/td\u003e\n\u003ctd\u003e1\/2\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003ctd\u003e140\u003c\/td\u003e\n\u003ctd\u003e220\u003c\/td\u003e\n\u003ctd\u003e360\u003c\/td\u003e\n\u003ctd\u003e550\u003c\/td\u003e\n\u003ctd\u003e880\u003c\/td\u003e\n\u003ctd\u003e1390\u003c\/td\u003e\n\u003ctd\u003e2260\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e230\u003c\/td\u003e\n\u003ctd\u003e1\/2\u003c\/td\u003e\n\u003ctd\u003e5.2\u003c\/td\u003e\n\u003ctd\u003e640\u003c\/td\u003e\n\u003ctd\u003e1000\u003c\/td\u003e\n\u003ctd\u003e1660\u003c\/td\u003e\n\u003ctd\u003e2250\u003c\/td\u003e\n\u003ctd\u003e4060\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e230\u003c\/td\u003e\n\u003ctd\u003e3\/4\u003c\/td\u003e\n\u003ctd\u003e8.4\u003c\/td\u003e\n\u003ctd\u003e400\u003c\/td\u003e\n\u003ctd\u003e620\u003c\/td\u003e\n\u003ctd\u003e1030\u003c\/td\u003e\n\u003ctd\u003e1580\u003c\/td\u003e\n\u003ctd\u003e2510\u003c\/td\u003e\n\u003ctd\u003e3970\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e230\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003ctd\u003e11.2\u003c\/td\u003e\n\u003ctd\u003e300\u003c\/td\u003e\n\u003ctd\u003e460\u003c\/td\u003e\n\u003ctd\u003e770\u003c\/td\u003e\n\u003ctd\u003e1190\u003c\/td\u003e\n\u003ctd\u003e1890\u003c\/td\u003e\n\u003ctd\u003e2980\u003c\/td\u003e\n\u003ctd\u003e4850\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e230\u003c\/td\u003e\n\u003ctd\u003e1-1\/2\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003ctd\u003e280\u003c\/td\u003e\n\u003ctd\u003e430\u003c\/td\u003e\n\u003ctd\u003e720\u003c\/td\u003e\n\u003ctd\u003e1110\u003c\/td\u003e\n\u003ctd\u003e1760\u003c\/td\u003e\n\u003ctd\u003e2780\u003c\/td\u003e\n\u003ctd\u003e4530\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"font-size:12.5px;color:#9B9EA3;margin-top:8px;line-height:1.55\"\u003eMaximum length in feet from the motor to the service entrance, copper wire, 9% voltage drop, from the Grundfos SQ, SQE installation and operating instructions and data booklet. A dash means not listed.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdiv style=\"display:flex;flex-wrap:wrap;gap:10px;margin:22px 0 4px\"\u003e\n\u003ca href=\"\/pages\/submersible-well-pump-sizing-calculator\" style=\"flex:1 1 200px;text-align:center;display:block;background:#B3122A;color:#ffffff;font-family:Arial Black,Arial,sans-serif;font-size:12px;text-transform:uppercase;letter-spacing:1.2px;padding:11px 18px;text-decoration:none\"\u003eSubmersible Calculator\u003c\/a\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eBefore You Buy — The Limits That Decide the Fit\u003c\/div\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eCheck\u003c\/th\u003e\n\u003cth\u003eWhat to confirm\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eWell size\u003c\/td\u003e\n\u003ctd\u003e3 in or larger casing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWater\u003c\/td\u003e\n\u003ctd\u003eClean water, pH 5 to 9, up to 86°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSetting\u003c\/td\u003e\n\u003ctd\u003eNo deeper than 500 ft below the static water level, and at least 20 in below the pumping water level\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower\u003c\/td\u003e\n\u003ctd\u003e1\/2 HP models come in 115 V or 230 V versions (different part numbers, not field-convertible); 3\/4 HP and up are 230 V only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWiring\u003c\/td\u003e\n\u003ctd\u003eCU 302 for constant pressure; or a pressure switch rated for the pump's current. Never a capacitor, control box or external drive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHorizontal install\u003c\/td\u003e\n\u003ctd\u003eUse the SQ\/SQE flow sleeve (on our \u003ca href=\"\/products\/grundfos-sq-sqe-pump-accessories\"\u003eGrundfos SQ and SQE Pump Accessories\u003c\/a\u003e listing) to keep water moving past the motor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGenerator\u003c\/td\u003e\n\u003ctd\u003eAt least the motor input power plus 50% (minimum plus 10%)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eMaterials of Construction\u003c\/div\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003ePart\u003c\/th\u003e\n\u003cth\u003eMaterial\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePump sleeve, outlet chamber, cable guard\u003c\/td\u003e\n\u003ctd\u003eAISI 304 stainless steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eImpellers, chambers, guide vanes, valve casing\u003c\/td\u003e\n\u003ctd\u003ePolyamide (30% glass-fibre reinforced)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eImpeller bearings\u003c\/td\u003e\n\u003ctd\u003eTungsten carbide \/ ceramic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShaft\u003c\/td\u003e\n\u003ctd\u003eAISI 304 stainless steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eValve seat, seals\u003c\/td\u003e\n\u003ctd\u003eNBR rubber\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor stator, rotor, top cover\u003c\/td\u003e\n\u003ctd\u003eAISI 304 stainless steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor bearings\u003c\/td\u003e\n\u003ctd\u003eSilicon carbide \/ tungsten carbide (coated); carbon thrust bearing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"font-size:12.5px;color:#9B9EA3;margin-top:8px;line-height:1.55\"\u003eSource: Grundfos SQ, SQE, SmartFlo and SP data booklet, construction.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"gs-contact\"\u003eFor engineering-led sizing and selection support or a factory submittal, email \u003ca href=\"mailto:sales@watermainsupply.com\"\u003esales@watermainsupply.com\u003c\/a\u003e or call \u003ca href=\"tel:18885104036\"\u003e1-888.510.4036\u003c\/a\u003e.\u003cbr\u003e© Watermain Supply — A division of E4 Industrial LLC\u003c\/div\u003e\n\n\u003c\/div\u003e\n\u003ch5\u003eData Sheet\u003c\/h5\u003e\u003cdiv class=\"gs\"\u003e\u003cdiv class=\"gs-dl\"\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0264\/1913\/4527\/files\/SQ_SQE_us.pdf?v=1788826864\" target=\"_blank\" rel=\"noopener\"\u003eSQ, SQE Installation and Operating Instructions\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0264\/1913\/4527\/files\/SQE_Brochure_2.pdf?v=1788826864\" target=\"_blank\" rel=\"noopener\"\u003eGrundfos SQE Constant Pressure Groundwater System Brochure\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0264\/1913\/4527\/files\/SQ_SQE_Brochure.pdf?v=1788826865\" target=\"_blank\" rel=\"noopener\"\u003eGrundfos SQ\/SQE Range Brochure\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0264\/1913\/4527\/files\/SQ_Performance_Curves.pdf?v=1788826864\" target=\"_blank\" rel=\"noopener\"\u003e3 in SQ Sizing Guide — Curves and Sizing Charts\u003c\/a\u003e\n\u003c\/div\u003e\u003c\/div\u003e\u003ch5\u003eVideos\u003c\/h5\u003e\u003cdiv class=\"gs\"\u003e\u003cdiv class=\"gs-sec\" style=\"margin-top:6px\"\u003e\n\u003cdiv style=\"display:grid;grid-template-columns:repeat(auto-fit,minmax(300px,1fr));gap:20px\"\u003e\n\u003cdiv\u003e\n\u003cdiv style=\"position:relative;width:100%;padding-top:56.25%;background:#4A4A4F\"\u003e\u003ciframe src=\"https:\/\/www.youtube.com\/embed\/_Kn3OVDRZOE?si=3DToNwIsKFSrV9Bt\" title=\"SQ and SQE: Constant Pressure Pump Overview\" loading=\"lazy\" frameborder=\"0\" style=\"position:absolute;top:0;left:0;width:100%;height:100%;border:0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share\" referrerpolicy=\"strict-origin-when-cross-origin\" allowfullscreen\u003e\u003c\/iframe\u003e\u003c\/div\u003e\n\u003cp style=\"font-family:Arial,Helvetica,sans-serif;font-size:13px;line-height:1.45;color:#4A4A4F;margin:8px 0 0\"\u003eSQ and SQE: Constant Pressure Pump Overview \u003cspan style=\"color:#9B9EA3\"\u003e(4:02)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cdiv style=\"position:relative;width:100%;padding-top:56.25%;background:#4A4A4F\"\u003e\u003ciframe src=\"https:\/\/www.youtube.com\/embed\/lHPdSndKQqs?si=tktPTsRHA2Z-H07V\" title=\"Installing a Grundfos SQE Constant Pressure System\" loading=\"lazy\" frameborder=\"0\" style=\"position:absolute;top:0;left:0;width:100%;height:100%;border:0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share\" referrerpolicy=\"strict-origin-when-cross-origin\" allowfullscreen\u003e\u003c\/iframe\u003e\u003c\/div\u003e\n\u003cp style=\"font-family:Arial,Helvetica,sans-serif;font-size:13px;line-height:1.45;color:#4A4A4F;margin:8px 0 0\"\u003eInstalling a Grundfos SQE Constant Pressure System \u003cspan style=\"color:#9B9EA3\"\u003e(5:22)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cdiv style=\"position:relative;width:100%;padding-top:56.25%;background:#4A4A4F\"\u003e\u003ciframe src=\"https:\/\/www.youtube.com\/embed\/U4gomM0GLr0?si=CP3NowIBbbzTzjEP\" title=\"Grundfos SQE Pump Restores Clean Water to a California Family\" loading=\"lazy\" frameborder=\"0\" style=\"position:absolute;top:0;left:0;width:100%;height:100%;border:0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share\" referrerpolicy=\"strict-origin-when-cross-origin\" allowfullscreen\u003e\u003c\/iframe\u003e\u003c\/div\u003e\n\u003cp style=\"font-family:Arial,Helvetica,sans-serif;font-size:13px;line-height:1.45;color:#4A4A4F;margin:8px 0 0\"\u003eGrundfos SQE Pump Restores Clean Water to a California Family \u003cspan style=\"color:#9B9EA3\"\u003e(6:42)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp style=\"font-family:Arial,Helvetica,sans-serif;font-size:12px;color:#9B9EA3;margin:16px 0 0\"\u003eVideos produced by Grundfos and hosted on YouTube.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/div\u003e\u003ch5\u003eGrundfos HOME App\u003c\/h5\u003e\u003cdiv class=\"gs\"\u003e\u003cdiv class=\"gs-sec\" style=\"margin-top:6px\"\u003e\n\u003cdiv class=\"gs-h\"\u003eSet Up \u0026amp; Monitor From Your Phone\u003c\/div\u003e\n\u003cdiv class=\"gs-lead\"\u003e\u003cp\u003eThe free Grundfos HOME app gives you full control of your water system from an iOS or Android phone. Pair an SQE with a CU 302 control unit and the app reports pump information around the clock, sends alert notifications on important events so you can act before the water goes off, and carries a built-in watering calendar with an internal clock so irrigation routines run to schedule without a timer. Installer details are stored in the app, so whoever set the system up is one tap away.\u003c\/p\u003e\u003c\/div\u003e\n\u003cdiv style=\"margin-top:16px\"\u003e\n\u003ca href=\"https:\/\/apps.apple.com\/us\/app\/grundfos-home\/id1592451846\" target=\"_blank\" rel=\"noopener\" style=\"display:inline-block;background:#B3122A;color:#fff!important;font-family:Arial Black,Arial,sans-serif;font-size:13px;letter-spacing:1px;text-transform:uppercase;text-decoration:none;padding:12px 24px;border-radius:999px;margin:0 10px 10px 0\"\u003eDownload for iOS\u003c\/a\u003e\u003ca href=\"https:\/\/play.google.com\/store\/apps\/details?id=com.grundfos.home\u0026amp;pcampaignid=web_share\" target=\"_blank\" rel=\"noopener\" style=\"display:inline-block;background:#4A4A4F;color:#fff!important;font-family:Arial Black,Arial,sans-serif;font-size:13px;letter-spacing:1px;text-transform:uppercase;text-decoration:none;padding:12px 24px;border-radius:999px;margin:0 10px 10px 0\"\u003eDownload for Android\u003c\/a\u003e\n\u003c\/div\u003e\n\u003cp style=\"font-size:12px;color:#9B9EA3;margin-top:14px;line-height:1.6\"\u003eGrundfos HOME is a free app from Grundfos Holding A\/S. It connects through the CU 302 control unit, which is required and is sold separately, and Bluetooth must be enabled on the CU 302 operating panel before pairing. Installers and service technicians use a separate free Grundfos app, Grundfos GO, as the commissioning and diagnostic tool; ask us for the link if you need it.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/div\u003e\u003c!-- \/TABS --\u003e","brand":"Grundfos","offers":[{"title":"1\/2 HP - 3 in Motor \/ 115V 1Ph 2-Wire \/ 15 SQE05-70 - 75 ft at 15 GPM","offer_id":47457479852207,"sku":"96160211","price":1292.81,"currency_code":"USD","in_stock":true},{"title":"1\/2 HP - 3 in Motor \/ 115V 1Ph 2-Wire \/ 15 SQE05-110 - 123 ft at 15 GPM","offer_id":47457479884975,"sku":"96160212","price":1297.2,"currency_code":"USD","in_stock":true},{"title":"1\/2 HP - 3 in Motor \/ 230V 1Ph 2-Wire \/ 15 SQE05-70 - 75 ft at 15 GPM","offer_id":47457479917743,"sku":"96160189","price":1292.81,"currency_code":"USD","in_stock":true},{"title":"1\/2 HP - 3 in Motor \/ 230V 1Ph 2-Wire \/ 15 SQE05-110 - 123 ft at 15 GPM","offer_id":47457479950511,"sku":"96160190","price":1297.2,"currency_code":"USD","in_stock":true},{"title":"3\/4 HP - 3 in Motor \/ 230V 1Ph 2-Wire \/ 15 SQE07-150 - 164 ft at 15 GPM","offer_id":47457479983279,"sku":"96160191","price":1524.68,"currency_code":"USD","in_stock":true},{"title":"3\/4 HP - 3 in Motor \/ 230V 1Ph 2-Wire \/ 15 SQE07-180 - 205 ft at 15 GPM","offer_id":47457480016047,"sku":"96160192","price":1606.15,"currency_code":"USD","in_stock":true},{"title":"1 HP - 3 in Motor \/ 230V 1Ph 2-Wire \/ 15 SQE10-220 - 246 ft at 15 GPM","offer_id":47457480048815,"sku":"96160193","price":1688.24,"currency_code":"USD","in_stock":true},{"title":"1 HP - 3 in Motor \/ 230V 1Ph 2-Wire \/ 15 SQE10-250 - 287 ft at 15 GPM","offer_id":47457480081583,"sku":"96160194","price":1712.68,"currency_code":"USD","in_stock":true},{"title":"1-1\/2 HP - 3 in Motor \/ 230V 1Ph 2-Wire \/ 15 SQE15-290 - 328 ft at 15 GPM","offer_id":47457480114351,"sku":"96160195","price":1930.76,"currency_code":"USD","in_stock":true},{"title":"1-1\/2 HP - 3 in Motor \/ 230V 1Ph 2-Wire \/ 15 SQE15-330 - 355 ft at 15 GPM","offer_id":47457480147119,"sku":"93001434","price":2027.89,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0264\/1913\/4527\/files\/Grundfos_SQE_Submersible_Pump.webp?v=1788826893"},{"product_id":"grundfos-22-sqe-submersible-well-pump","title":"Grundfos 22 SQE Submersible Well Pump","description":"\u003c!-- TABS --\u003e\n\u003ch5\u003eDescription\u003c\/h5\u003e\n\u003cdiv class=\"gs\"\u003e\n\n\u003cdiv class=\"gs-head\"\u003e\n\u003cdiv class=\"gs-eyebrow\"\u003eGrundfos · 3 in Submersible Well Pump\u003c\/div\u003e\n\u003cdiv class=\"gs-title\"\u003e22 SQE\u003c\/div\u003e\n\u003cdiv class=\"gs-sub\"\u003eNominal 22 GPM 3 in constant-pressure submersible well pump with a permanent-magnet motor and built-in protection: 6 models from 1\/2 to 1-1\/2 HP, 36-240 ft of head at 22 GPM, 1-1\/2 in NPT discharge. Runs on a CU 302 for constant pressure.\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"gs-badges\"\u003e\n\u003cdiv class=\"gs-badge\" style=\"background:#B3122A;color:#FFFFFF;border-color:#B3122A\"\u003e22 GPM Rated Flow\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003e1\/2 to 1-1\/2 HP\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003e36-240 ft at 22 GPM\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003e7-33 GPM Flow Range\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003eConstant Pressure with CU 302\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003e3 in Min. Well\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003e1-1\/2 in NPT Discharge\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003e115V or 230V 1Ph\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003eDry-Run, Voltage and Overload Protection\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003e2.9 in Dia x 29.1-36.9 in L\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003e11-16 lb Ship Weight\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eOverview\u003c\/div\u003e\n\u003cdiv class=\"gs-lead\"\u003e\n\u003cp\u003eThe Grundfos 22 SQE is a 3 in stainless steel well pump with a variable-speed permanent-magnet \"Smart Motor\". Paired with a \u003ca href=\"\/products\/grundfos-cu-302-constant-pressure-control\"\u003eGrundfos CU 302 Constant Pressure Control\u003c\/a\u003e, it holds the pressure you set, from a trickle at one tap to full flow, instead of cycling between a pressure switch's cut-in and cut-out. The CU 302 talks to the pump over the power leads, so no extra wires go down the well, and it pairs with the Grundfos GO and HOME apps by Bluetooth.\u003c\/p\u003e\n\u003cp\u003eIt is rated at 22 GPM, with 6 models from 1\/2 to 1-1\/2 HP for deeper settings. The pump fits a 3 in or larger well and suits household supply, light commercial service, irrigation and tank filling or emptying.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eConstant pressure.\u003c\/strong\u003e The CU 302 changes pump speed, 3,000 to 10,700 rpm, to hold its setpoint (factory 50 PSI, adjustable 20 to 100 PSI in 5 PSI steps). It works with a 2 gal diaphragm tank instead of a large pressure tank.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBuilt-in protection.\u003c\/strong\u003e Dry-run, over- and undervoltage (cuts out below 150 V and above 315 V and restarts by itself), overload, locked-rotor and over-temperature protection are built into the motor. No protection relay or motor starter needed.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSoft start, no start limit.\u003c\/strong\u003e The motor ramps up in about 3 seconds and has no limit on starts or stops per hour.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSand-tolerant hydraulics.\u003c\/strong\u003e Floating impellers each run on their own tungsten carbide \/ ceramic bearing; a top bearing protects pump and motor against upthrust at start-up.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall it any way up.\u003c\/strong\u003e Vertical, horizontal or anywhere between, with a built-in spring check valve; use a flow sleeve when horizontal.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"background:#FFFFFF;border:1px solid #C7CBD1;border-top:3px solid #B3122A;padding:12px 16px 12px;margin:16px 0 4px;font-size:13.5px;line-height:1.55;color:#4A4A4F\"\u003e\n\u003cdiv style=\"font-family:Arial Black,Arial,sans-serif;font-size:11px;letter-spacing:1.2px;text-transform:uppercase;color:#B3122A;margin-bottom:8px\"\u003eWhat Ships and What It Needs to Run\u003c\/div\u003e\n\u003cp style=\"margin:0 0 6px\"\u003e\u003cstrong style=\"color:#B3122A\"\u003eIncluded:\u003c\/strong\u003e the pump and its 3 in SQE motor, assembled, with a built-in check valve, plus a 5 ft, 14 AWG motor cable with plug that you press onto the motor socket and secure with four screws. The controller is \u003cstrong\u003enot\u003c\/strong\u003e in the box.\u003c\/p\u003e\n\u003cp style=\"margin:0 0 6px\"\u003e\u003cstrong style=\"color:#B3122A\"\u003eFor constant pressure: CU 302 and a pressure sensor, ordered separately.\u003c\/strong\u003e Use the \u003ca href=\"\/products\/grundfos-cu-302-constant-pressure-control\"\u003eGrundfos CU 302 Constant Pressure Control\u003c\/a\u003e, sold with or without its 0-120 PSI pressure sensor, plus a 2 gal diaphragm tank. Variable speed needs the CU 302.\u003c\/p\u003e\n\u003cp style=\"margin:0 0 6px\"\u003e\u003cstrong style=\"color:#B3122A\"\u003eWithout a controller:\u003c\/strong\u003e Grundfos states the motor can be connected directly to the main breaker and started by a pressure switch rated for the pump's current; it then runs at full speed, like an SQ, with no constant pressure.\u003c\/p\u003e\n\u003cp style=\"margin:0 0 6px\"\u003e\u003cstrong style=\"color:#B3122A\"\u003eNever connect:\u003c\/strong\u003e a capacitor, a conventional control box or an external frequency drive.\u003c\/p\u003e\n\u003cp style=\"margin:0\"\u003e\u003cstrong style=\"color:#B3122A\"\u003eDrop cable and splice kit:\u003c\/strong\u003e sized to your setting depth (cable table under Models \u0026amp; Performance) and ordered separately. A replacement motor cable is on our \u003ca href=\"\/products\/grundfos-sq-sqe-pump-accessories\"\u003eGrundfos SQ and SQE Pump Accessories\u003c\/a\u003e listing; you do not need one for a new pump.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"background:#E1E3E6;border-left:3px solid #B8BDC4;padding:8px 14px;font-size:11.5px;color:#4A4A4F;margin-top:14px;line-height:1.5\"\u003eGenuine Grundfos equipment, factory-new in original packaging — sold and supported by Watermain Supply, an independent industrial supplier.\u003c\/div\u003e\n\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eWarranty\u003c\/div\u003e\n\u003cdiv class=\"gs-lead\"\u003e\u003cp\u003e24 months from date of installation, but not more than 30 months from date of manufacture. In Grundfos's words, products are “warranted to the original user only to be free of defects in material and workmanship”; the full terms are in the installation and operating instructions on the Data Sheet tab.\u003c\/p\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eSpecifications\u003c\/div\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated flow\u003c\/td\u003e\n\u003ctd\u003e22 GPM nominal; working range 7-33 GPM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHorsepower\u003c\/td\u003e\n\u003ctd\u003e1\/2 to 1-1\/2 HP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply\u003c\/td\u003e\n\u003ctd\u003e1 x 100-115 V (1\/2 HP only) or 1 x 200-240 V, 60 Hz; 2-wire plus ground\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor\u003c\/td\u003e\n\u003ctd\u003eMSE 3 permanent-magnet motor with built-in electronics, 3,000 to 10,700 rpm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl\u003c\/td\u003e\n\u003ctd\u003eCU 302 over the power leads (GENIbus); Bluetooth to Grundfos GO and the Grundfos HOME app\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection\u003c\/td\u003e\n\u003ctd\u003eDry run, overvoltage and undervoltage (cuts out below 150 V and above 315 V), overload, locked rotor, over-temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStarting\u003c\/td\u003e\n\u003ctd\u003eSoft start, run-up maximum 3 seconds; no limit on starts or stops per hour\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor cable\u003c\/td\u003e\n\u003ctd\u003e3-wire, 14 AWG XLPE, 5 ft, with plug\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDischarge\u003c\/td\u003e\n\u003ctd\u003e1-1\/2 in NPT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWell diameter\u003c\/td\u003e\n\u003ctd\u003e3 in minimum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSetting depth\u003c\/td\u003e\n\u003ctd\u003eUp to 500 ft below the static water level; at least 20 in below the pumping water level\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePumped liquid\u003c\/td\u003e\n\u003ctd\u003eClean water, pH 5 to 9, up to 86°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGenerator\u003c\/td\u003e\n\u003ctd\u003eOutput at least the motor input power (P1) plus 50% recommended, never less than P1 plus 10%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"font-size:12.5px;color:#9B9EA3;margin-top:8px;line-height:1.55\"\u003eSource: Grundfos SQ, SQE, SmartFlo and SP data booklet (North America, 60 Hz), technical data.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eModels \u0026amp; Performance — Will It Do What You Need?\u003c\/div\u003e\n\u003cp style=\"font-size:13.5px;margin-bottom:10px\"\u003ePick a model whose head at your flow covers the pumping water level, the pressure you need at the surface (2.31 ft per PSI) and pipe friction. Then check the set-pressure table for what it delivers at your depth.\u003c\/p\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003cth\u003eHP\u003c\/th\u003e\n\u003cth\u003e0 GPM (Shut-off)\u003c\/th\u003e\n\u003cth\u003e6.5 GPM\u003c\/th\u003e\n\u003cth\u003e16.2 GPM\u003c\/th\u003e\n\u003cth\u003e22 GPM (Rated)\u003c\/th\u003e\n\u003cth\u003e32.4 GPM (Max)\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e22 SQE05-40\u003c\/td\u003e\n\u003ctd\u003e1\/2\u003c\/td\u003e\n\u003ctd\u003e60\u003c\/td\u003e\n\u003ctd\u003e55\u003c\/td\u003e\n\u003ctd\u003e46\u003c\/td\u003e\n\u003ctd\u003e36\u003c\/td\u003e\n\u003ctd\u003e0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e22 SQE05-80\u003c\/td\u003e\n\u003ctd\u003e1\/2\u003c\/td\u003e\n\u003ctd\u003e119\u003c\/td\u003e\n\u003ctd\u003e110\u003c\/td\u003e\n\u003ctd\u003e95\u003c\/td\u003e\n\u003ctd\u003e77\u003c\/td\u003e\n\u003ctd\u003e21\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e22 SQE07-120\u003c\/td\u003e\n\u003ctd\u003e3\/4\u003c\/td\u003e\n\u003ctd\u003e176\u003c\/td\u003e\n\u003ctd\u003e165\u003c\/td\u003e\n\u003ctd\u003e143\u003c\/td\u003e\n\u003ctd\u003e117\u003c\/td\u003e\n\u003ctd\u003e42\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e22 SQE10-160\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003ctd\u003e233\u003c\/td\u003e\n\u003ctd\u003e220\u003c\/td\u003e\n\u003ctd\u003e191\u003c\/td\u003e\n\u003ctd\u003e159\u003c\/td\u003e\n\u003ctd\u003e62\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e22 SQE10-190\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003ctd\u003e291\u003c\/td\u003e\n\u003ctd\u003e274\u003c\/td\u003e\n\u003ctd\u003e240\u003c\/td\u003e\n\u003ctd\u003e200\u003c\/td\u003e\n\u003ctd\u003e82\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e22 SQE15-220\u003c\/td\u003e\n\u003ctd\u003e1-1\/2\u003c\/td\u003e\n\u003ctd\u003e348\u003c\/td\u003e\n\u003ctd\u003e329\u003c\/td\u003e\n\u003ctd\u003e288\u003c\/td\u003e\n\u003ctd\u003e240\u003c\/td\u003e\n\u003ctd\u003e102\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"font-size:12.5px;color:#9B9EA3;margin-top:8px;line-height:1.55\"\u003eTotal head in feet. The shut-off and flow columns are read from the Grundfos 60 Hz curves for the 22 SQ, SQE (SQ and SQE share one curve, the SQE at its 10,700 rpm top speed), digitized from the published curve charts in the Grundfos SQ, SQE, SmartFlo and SP data booklet, at the nearest published point and rounded down. The (Rated) column is the head Grundfos prints at 22 GPM in its system sizing matrix, verbatim; the number in the model name is a nominal figure and reads lower on some models. 1 ft of head = 0.433 PSI. Full curves are in the product images and on the Data Sheet tab.\u003c\/p\u003e\n\u003cp style=\"font-size:13.5px;margin-bottom:10px;margin-top:18px\"\u003e\u003cstrong\u003eWhat It Delivers at Your Set Pressure\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdetails open style=\"margin:8px 0;border-top:3px solid #B3122A;padding:0 4px 6px\"\u003e\u003csummary style=\"cursor:pointer;padding:8px 0;font-weight:bold;color:#4A4A4F\"\u003eOutput at 50 and 60 PSI · 3\/4 HP · 1 model · depths 20 to 40 ft\u003c\/summary\u003e\n\u003cp\u003e\u003cstrong\u003eGPM at 50 PSI\u003c\/strong\u003e (CU 302 factory setpoint), by depth to water\u003c\/p\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003cth\u003e20 ft\u003c\/th\u003e\n\u003cth\u003e40 ft\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e22 SQE07-120\u003c\/td\u003e\n\u003ctd\u003e18.4\u003c\/td\u003e\n\u003ctd\u003e11.9\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp\u003e\u003cstrong\u003eGPM at 60 PSI\u003c\/strong\u003e (setpoint), by depth to water\u003c\/p\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003cth\u003e20 ft\u003c\/th\u003e\n\u003cth\u003e40 ft\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e22 SQE07-120\u003c\/td\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails style=\"margin:8px 0;border-top:3px solid #B3122A;padding:0 4px 6px\"\u003e\u003csummary style=\"cursor:pointer;padding:8px 0;font-weight:bold;color:#4A4A4F\"\u003eOutput at 50 and 60 PSI · 1 to 1-1\/2 HP · 3 models · depths 20 to 200 ft\u003c\/summary\u003e\n\u003cp\u003e\u003cstrong\u003eGPM at 50 PSI\u003c\/strong\u003e (CU 302 factory setpoint), by depth to water\u003c\/p\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003cth\u003e20 ft\u003c\/th\u003e\n\u003cth\u003e60 ft\u003c\/th\u003e\n\u003cth\u003e80 ft\u003c\/th\u003e\n\u003cth\u003e100 ft\u003c\/th\u003e\n\u003cth\u003e140 ft\u003c\/th\u003e\n\u003cth\u003e180 ft\u003c\/th\u003e\n\u003cth\u003e200 ft\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e22 SQE10-160\u003c\/td\u003e\n\u003ctd\u003e25.3\u003c\/td\u003e\n\u003ctd\u003e19.5\u003c\/td\u003e\n\u003ctd\u003e15.6\u003c\/td\u003e\n\u003ctd\u003e8.9\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e22 SQE10-190\u003c\/td\u003e\n\u003ctd\u003e28.3\u003c\/td\u003e\n\u003ctd\u003e24.8\u003c\/td\u003e\n\u003ctd\u003e22.7\u003c\/td\u003e\n\u003ctd\u003e20.1\u003c\/td\u003e\n\u003ctd\u003e12.8\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e22 SQE15-220\u003c\/td\u003e\n\u003ctd\u003e30.2\u003c\/td\u003e\n\u003ctd\u003e27.7\u003c\/td\u003e\n\u003ctd\u003e26.2\u003c\/td\u003e\n\u003ctd\u003e24.7\u003c\/td\u003e\n\u003ctd\u003e20.4\u003c\/td\u003e\n\u003ctd\u003e15.1\u003c\/td\u003e\n\u003ctd\u003e10.8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp\u003e\u003cstrong\u003eGPM at 60 PSI\u003c\/strong\u003e (setpoint), by depth to water\u003c\/p\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003cth\u003e20 ft\u003c\/th\u003e\n\u003cth\u003e60 ft\u003c\/th\u003e\n\u003cth\u003e80 ft\u003c\/th\u003e\n\u003cth\u003e100 ft\u003c\/th\u003e\n\u003cth\u003e140 ft\u003c\/th\u003e\n\u003cth\u003e180 ft\u003c\/th\u003e\n\u003cth\u003e200 ft\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e22 SQE10-160\u003c\/td\u003e\n\u003ctd\u003e22.2\u003c\/td\u003e\n\u003ctd\u003e14\u003c\/td\u003e\n\u003ctd\u003e7.6\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e22 SQE10-190\u003c\/td\u003e\n\u003ctd\u003e26.5\u003c\/td\u003e\n\u003ctd\u003e22.2\u003c\/td\u003e\n\u003ctd\u003e19.5\u003c\/td\u003e\n\u003ctd\u003e16.6\u003c\/td\u003e\n\u003ctd\u003e5.8\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e22 SQE15-220\u003c\/td\u003e\n\u003ctd\u003e28.7\u003c\/td\u003e\n\u003ctd\u003e26\u003c\/td\u003e\n\u003ctd\u003e24.2\u003c\/td\u003e\n\u003ctd\u003e22.3\u003c\/td\u003e\n\u003ctd\u003e17.9\u003c\/td\u003e\n\u003ctd\u003e9.5\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cp style=\"font-size:12.5px;color:#9B9EA3;margin-top:8px;line-height:1.55\"\u003eFrom the Grundfos 3 in SQ sizing charts (pp. 42-43), verbatim: gallons per minute at the pressure shown and the depth to pumping water level. The SQE runs on the same curve as the SQ at full speed, so each cell is the most the SQE delivers while the CU 302 holds that pressure. Riser and pipe friction are not included. A dash means Grundfos prints no figure: on the shallow side the flow is past the chart range, on the deep side the pump cannot hold that pressure. Not shown: 22 SQE05-40, 22 SQE05-80, which Grundfos charts below 50 PSI at every depth; use them on a lower setpoint or for transfer duty.\u003c\/p\u003e\n\u003cp style=\"font-size:13.5px;margin-bottom:10px;margin-top:18px\"\u003e\u003cstrong\u003eDrop Cable Size\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdetails style=\"margin:8px 0;border-top:3px solid #B3122A;padding:0 4px 6px\"\u003e\u003csummary style=\"cursor:pointer;padding:8px 0;font-weight:bold;color:#4A4A4F\"\u003eDrop cable size by distance · copper, 60 Hz\u003c\/summary\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eVolts\u003c\/th\u003e\n\u003cth\u003eHP\u003c\/th\u003e\n\u003cth\u003eAmps\u003c\/th\u003e\n\u003cth\u003e14 AWG\u003c\/th\u003e\n\u003cth\u003e12 AWG\u003c\/th\u003e\n\u003cth\u003e10 AWG\u003c\/th\u003e\n\u003cth\u003e8 AWG\u003c\/th\u003e\n\u003cth\u003e6 AWG\u003c\/th\u003e\n\u003cth\u003e4 AWG\u003c\/th\u003e\n\u003cth\u003e2 AWG\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e115\u003c\/td\u003e\n\u003ctd\u003e1\/2\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003ctd\u003e140\u003c\/td\u003e\n\u003ctd\u003e220\u003c\/td\u003e\n\u003ctd\u003e360\u003c\/td\u003e\n\u003ctd\u003e550\u003c\/td\u003e\n\u003ctd\u003e880\u003c\/td\u003e\n\u003ctd\u003e1390\u003c\/td\u003e\n\u003ctd\u003e2260\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e230\u003c\/td\u003e\n\u003ctd\u003e1\/2\u003c\/td\u003e\n\u003ctd\u003e5.2\u003c\/td\u003e\n\u003ctd\u003e640\u003c\/td\u003e\n\u003ctd\u003e1000\u003c\/td\u003e\n\u003ctd\u003e1660\u003c\/td\u003e\n\u003ctd\u003e2250\u003c\/td\u003e\n\u003ctd\u003e4060\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e230\u003c\/td\u003e\n\u003ctd\u003e3\/4\u003c\/td\u003e\n\u003ctd\u003e8.4\u003c\/td\u003e\n\u003ctd\u003e400\u003c\/td\u003e\n\u003ctd\u003e620\u003c\/td\u003e\n\u003ctd\u003e1030\u003c\/td\u003e\n\u003ctd\u003e1580\u003c\/td\u003e\n\u003ctd\u003e2510\u003c\/td\u003e\n\u003ctd\u003e3970\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e230\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003ctd\u003e11.2\u003c\/td\u003e\n\u003ctd\u003e300\u003c\/td\u003e\n\u003ctd\u003e460\u003c\/td\u003e\n\u003ctd\u003e770\u003c\/td\u003e\n\u003ctd\u003e1190\u003c\/td\u003e\n\u003ctd\u003e1890\u003c\/td\u003e\n\u003ctd\u003e2980\u003c\/td\u003e\n\u003ctd\u003e4850\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e230\u003c\/td\u003e\n\u003ctd\u003e1-1\/2\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003ctd\u003e280\u003c\/td\u003e\n\u003ctd\u003e430\u003c\/td\u003e\n\u003ctd\u003e720\u003c\/td\u003e\n\u003ctd\u003e1110\u003c\/td\u003e\n\u003ctd\u003e1760\u003c\/td\u003e\n\u003ctd\u003e2780\u003c\/td\u003e\n\u003ctd\u003e4530\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"font-size:12.5px;color:#9B9EA3;margin-top:8px;line-height:1.55\"\u003eMaximum length in feet from the motor to the service entrance, copper wire, 9% voltage drop, from the Grundfos SQ, SQE installation and operating instructions and data booklet. A dash means not listed.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdiv style=\"display:flex;flex-wrap:wrap;gap:10px;margin:22px 0 4px\"\u003e\n\u003ca href=\"\/pages\/submersible-well-pump-sizing-calculator\" style=\"flex:1 1 200px;text-align:center;display:block;background:#B3122A;color:#ffffff;font-family:Arial Black,Arial,sans-serif;font-size:12px;text-transform:uppercase;letter-spacing:1.2px;padding:11px 18px;text-decoration:none\"\u003eSubmersible Calculator\u003c\/a\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eBefore You Buy — The Limits That Decide the Fit\u003c\/div\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eCheck\u003c\/th\u003e\n\u003cth\u003eWhat to confirm\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eWell size\u003c\/td\u003e\n\u003ctd\u003e3 in or larger casing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWater\u003c\/td\u003e\n\u003ctd\u003eClean water, pH 5 to 9, up to 86°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSetting\u003c\/td\u003e\n\u003ctd\u003eNo deeper than 500 ft below the static water level, and at least 20 in below the pumping water level\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower\u003c\/td\u003e\n\u003ctd\u003e1\/2 HP models come in 115 V or 230 V versions (different part numbers, not field-convertible); 3\/4 HP and up are 230 V only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWiring\u003c\/td\u003e\n\u003ctd\u003eCU 302 for constant pressure; or a pressure switch rated for the pump's current. Never a capacitor, control box or external drive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHorizontal install\u003c\/td\u003e\n\u003ctd\u003eUse the SQ\/SQE flow sleeve (on our \u003ca href=\"\/products\/grundfos-sq-sqe-pump-accessories\"\u003eGrundfos SQ and SQE Pump Accessories\u003c\/a\u003e listing) to keep water moving past the motor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGenerator\u003c\/td\u003e\n\u003ctd\u003eAt least the motor input power plus 50% (minimum plus 10%)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eMaterials of Construction\u003c\/div\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003ePart\u003c\/th\u003e\n\u003cth\u003eMaterial\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePump sleeve, outlet chamber, cable guard\u003c\/td\u003e\n\u003ctd\u003eAISI 304 stainless steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eImpellers, chambers, guide vanes, valve casing\u003c\/td\u003e\n\u003ctd\u003ePolyamide (30% glass-fibre reinforced)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eImpeller bearings\u003c\/td\u003e\n\u003ctd\u003eTungsten carbide \/ ceramic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShaft\u003c\/td\u003e\n\u003ctd\u003eAISI 304 stainless steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eValve seat, seals\u003c\/td\u003e\n\u003ctd\u003eNBR rubber\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor stator, rotor, top cover\u003c\/td\u003e\n\u003ctd\u003eAISI 304 stainless steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor bearings\u003c\/td\u003e\n\u003ctd\u003eSilicon carbide \/ tungsten carbide (coated); carbon thrust bearing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"font-size:12.5px;color:#9B9EA3;margin-top:8px;line-height:1.55\"\u003eSource: Grundfos SQ, SQE, SmartFlo and SP data booklet, construction.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"gs-contact\"\u003eFor engineering-led sizing and selection support or a factory submittal, email \u003ca href=\"mailto:sales@watermainsupply.com\"\u003esales@watermainsupply.com\u003c\/a\u003e or call \u003ca href=\"tel:18885104036\"\u003e1-888.510.4036\u003c\/a\u003e.\u003cbr\u003e© Watermain Supply — A division of E4 Industrial LLC\u003c\/div\u003e\n\n\u003c\/div\u003e\n\u003ch5\u003eData Sheet\u003c\/h5\u003e\u003cdiv class=\"gs\"\u003e\u003cdiv class=\"gs-dl\"\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0264\/1913\/4527\/files\/SQ_SQE_us.pdf?v=1788826864\" target=\"_blank\" rel=\"noopener\"\u003eSQ, SQE Installation and Operating Instructions\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0264\/1913\/4527\/files\/SQE_Brochure_2.pdf?v=1788826864\" target=\"_blank\" rel=\"noopener\"\u003eGrundfos SQE Constant Pressure Groundwater System Brochure\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0264\/1913\/4527\/files\/SQ_SQE_Brochure.pdf?v=1788826865\" target=\"_blank\" rel=\"noopener\"\u003eGrundfos SQ\/SQE Range Brochure\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0264\/1913\/4527\/files\/SQ_Performance_Curves.pdf?v=1788826864\" target=\"_blank\" rel=\"noopener\"\u003e3 in SQ Sizing Guide — Curves and Sizing Charts\u003c\/a\u003e\n\u003c\/div\u003e\u003c\/div\u003e\u003ch5\u003eVideos\u003c\/h5\u003e\u003cdiv class=\"gs\"\u003e\u003cdiv class=\"gs-sec\" style=\"margin-top:6px\"\u003e\n\u003cdiv style=\"display:grid;grid-template-columns:repeat(auto-fit,minmax(300px,1fr));gap:20px\"\u003e\n\u003cdiv\u003e\n\u003cdiv style=\"position:relative;width:100%;padding-top:56.25%;background:#4A4A4F\"\u003e\u003ciframe src=\"https:\/\/www.youtube.com\/embed\/_Kn3OVDRZOE?si=3DToNwIsKFSrV9Bt\" title=\"SQ and SQE: Constant Pressure Pump Overview\" loading=\"lazy\" frameborder=\"0\" style=\"position:absolute;top:0;left:0;width:100%;height:100%;border:0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share\" referrerpolicy=\"strict-origin-when-cross-origin\" allowfullscreen\u003e\u003c\/iframe\u003e\u003c\/div\u003e\n\u003cp style=\"font-family:Arial,Helvetica,sans-serif;font-size:13px;line-height:1.45;color:#4A4A4F;margin:8px 0 0\"\u003eSQ and SQE: Constant Pressure Pump Overview \u003cspan style=\"color:#9B9EA3\"\u003e(4:02)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cdiv style=\"position:relative;width:100%;padding-top:56.25%;background:#4A4A4F\"\u003e\u003ciframe src=\"https:\/\/www.youtube.com\/embed\/lHPdSndKQqs?si=tktPTsRHA2Z-H07V\" title=\"Installing a Grundfos SQE Constant Pressure System\" loading=\"lazy\" frameborder=\"0\" style=\"position:absolute;top:0;left:0;width:100%;height:100%;border:0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share\" referrerpolicy=\"strict-origin-when-cross-origin\" allowfullscreen\u003e\u003c\/iframe\u003e\u003c\/div\u003e\n\u003cp style=\"font-family:Arial,Helvetica,sans-serif;font-size:13px;line-height:1.45;color:#4A4A4F;margin:8px 0 0\"\u003eInstalling a Grundfos SQE Constant Pressure System \u003cspan style=\"color:#9B9EA3\"\u003e(5:22)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cdiv style=\"position:relative;width:100%;padding-top:56.25%;background:#4A4A4F\"\u003e\u003ciframe src=\"https:\/\/www.youtube.com\/embed\/U4gomM0GLr0?si=CP3NowIBbbzTzjEP\" title=\"Grundfos SQE Pump Restores Clean Water to a California Family\" loading=\"lazy\" frameborder=\"0\" style=\"position:absolute;top:0;left:0;width:100%;height:100%;border:0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share\" referrerpolicy=\"strict-origin-when-cross-origin\" allowfullscreen\u003e\u003c\/iframe\u003e\u003c\/div\u003e\n\u003cp style=\"font-family:Arial,Helvetica,sans-serif;font-size:13px;line-height:1.45;color:#4A4A4F;margin:8px 0 0\"\u003eGrundfos SQE Pump Restores Clean Water to a California Family \u003cspan style=\"color:#9B9EA3\"\u003e(6:42)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp style=\"font-family:Arial,Helvetica,sans-serif;font-size:12px;color:#9B9EA3;margin:16px 0 0\"\u003eVideos produced by Grundfos and hosted on YouTube.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/div\u003e\u003ch5\u003eGrundfos HOME App\u003c\/h5\u003e\u003cdiv class=\"gs\"\u003e\u003cdiv class=\"gs-sec\" style=\"margin-top:6px\"\u003e\n\u003cdiv class=\"gs-h\"\u003eSet Up \u0026amp; Monitor From Your Phone\u003c\/div\u003e\n\u003cdiv class=\"gs-lead\"\u003e\u003cp\u003eThe free Grundfos HOME app gives you full control of your water system from an iOS or Android phone. Pair an SQE with a CU 302 control unit and the app reports pump information around the clock, sends alert notifications on important events so you can act before the water goes off, and carries a built-in watering calendar with an internal clock so irrigation routines run to schedule without a timer. Installer details are stored in the app, so whoever set the system up is one tap away.\u003c\/p\u003e\u003c\/div\u003e\n\u003cdiv style=\"margin-top:16px\"\u003e\n\u003ca href=\"https:\/\/apps.apple.com\/us\/app\/grundfos-home\/id1592451846\" target=\"_blank\" rel=\"noopener\" style=\"display:inline-block;background:#B3122A;color:#fff!important;font-family:Arial Black,Arial,sans-serif;font-size:13px;letter-spacing:1px;text-transform:uppercase;text-decoration:none;padding:12px 24px;border-radius:999px;margin:0 10px 10px 0\"\u003eDownload for iOS\u003c\/a\u003e\u003ca href=\"https:\/\/play.google.com\/store\/apps\/details?id=com.grundfos.home\u0026amp;pcampaignid=web_share\" target=\"_blank\" rel=\"noopener\" style=\"display:inline-block;background:#4A4A4F;color:#fff!important;font-family:Arial Black,Arial,sans-serif;font-size:13px;letter-spacing:1px;text-transform:uppercase;text-decoration:none;padding:12px 24px;border-radius:999px;margin:0 10px 10px 0\"\u003eDownload for Android\u003c\/a\u003e\n\u003c\/div\u003e\n\u003cp style=\"font-size:12px;color:#9B9EA3;margin-top:14px;line-height:1.6\"\u003eGrundfos HOME is a free app from Grundfos Holding A\/S. It connects through the CU 302 control unit, which is required and is sold separately, and Bluetooth must be enabled on the CU 302 operating panel before pairing. Installers and service technicians use a separate free Grundfos app, Grundfos GO, as the commissioning and diagnostic tool; ask us for the link if you need it.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/div\u003e\u003c!-- \/TABS --\u003e","brand":"Grundfos","offers":[{"title":"1\/2 HP - 3 in Motor \/ 115V 1Ph 2-Wire \/ 22 SQE05-40 - 36 ft at 22 GPM","offer_id":47457480179887,"sku":"96160213","price":1275.27,"currency_code":"USD","in_stock":true},{"title":"1\/2 HP - 3 in Motor \/ 115V 1Ph 2-Wire \/ 22 SQE05-80 - 77 ft at 22 GPM","offer_id":47457480212655,"sku":"96160214","price":1334.8,"currency_code":"USD","in_stock":true},{"title":"1\/2 HP - 3 in Motor \/ 230V 1Ph 2-Wire \/ 22 SQE05-40 - 36 ft at 22 GPM","offer_id":47457480245423,"sku":"96160196","price":1275.27,"currency_code":"USD","in_stock":true},{"title":"1\/2 HP - 3 in Motor \/ 230V 1Ph 2-Wire \/ 22 SQE05-80 - 77 ft at 22 GPM","offer_id":47457480278191,"sku":"96160197","price":1334.8,"currency_code":"USD","in_stock":true},{"title":"3\/4 HP - 3 in Motor \/ 230V 1Ph 2-Wire \/ 22 SQE07-120 - 117 ft at 22 GPM","offer_id":47457480310959,"sku":"96160198","price":1524.68,"currency_code":"USD","in_stock":true},{"title":"1 HP - 3 in Motor \/ 230V 1Ph 2-Wire \/ 22 SQE10-160 - 159 ft at 22 GPM","offer_id":47457480343727,"sku":"96160199","price":1665.68,"currency_code":"USD","in_stock":true},{"title":"1 HP - 3 in Motor \/ 230V 1Ph 2-Wire \/ 22 SQE10-190 - 200 ft at 22 GPM","offer_id":47457480376495,"sku":"96160200","price":1740.88,"currency_code":"USD","in_stock":true},{"title":"1-1\/2 HP - 3 in Motor \/ 230V 1Ph 2-Wire \/ 22 SQE15-220 - 240 ft at 22 GPM","offer_id":47457480409263,"sku":"96160201","price":2041.05,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0264\/1913\/4527\/files\/Grundfos_SQE_Submersible_Pump.webp?v=1788826893"},{"product_id":"grundfos-30-sqe-submersible-well-pump","title":"Grundfos 30 SQE Submersible Well Pump","description":"\u003c!-- TABS --\u003e\n\u003ch5\u003eDescription\u003c\/h5\u003e\n\u003cdiv class=\"gs\"\u003e\n\n\u003cdiv class=\"gs-head\"\u003e\n\u003cdiv class=\"gs-eyebrow\"\u003eGrundfos · 3 in Submersible Well Pump\u003c\/div\u003e\n\u003cdiv class=\"gs-title\"\u003e30 SQE\u003c\/div\u003e\n\u003cdiv class=\"gs-sub\"\u003eNominal 30 GPM 3 in constant-pressure submersible well pump with a permanent-magnet motor and built-in protection: 4 models from 1\/2 to 1-1\/2 HP, 33-176 ft of head at 30 GPM, 1-1\/2 in NPT discharge. Runs on a CU 302 for constant pressure.\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"gs-badges\"\u003e\n\u003cdiv class=\"gs-badge\" style=\"background:#B3122A;color:#FFFFFF;border-color:#B3122A\"\u003e30 GPM Rated Flow\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003e1\/2 to 1-1\/2 HP\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003e33-176 ft at 30 GPM\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003e8-42 GPM Flow Range\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003eConstant Pressure with CU 302\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003e3 in Min. Well\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003e1-1\/2 in NPT Discharge\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003e115V or 230V 1Ph\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003eDry-Run, Voltage and Overload Protection\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003e2.9 in Dia x 29.1-33.7 in L\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003e11-15 lb Ship Weight\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eOverview\u003c\/div\u003e\n\u003cdiv class=\"gs-lead\"\u003e\n\u003cp\u003eThe Grundfos 30 SQE is a 3 in stainless steel well pump with a variable-speed permanent-magnet \"Smart Motor\". Paired with a \u003ca href=\"\/products\/grundfos-cu-302-constant-pressure-control\"\u003eGrundfos CU 302 Constant Pressure Control\u003c\/a\u003e, it holds the pressure you set, from a trickle at one tap to full flow, instead of cycling between a pressure switch's cut-in and cut-out. The CU 302 talks to the pump over the power leads, so no extra wires go down the well, and it pairs with the Grundfos GO and HOME apps by Bluetooth.\u003c\/p\u003e\n\u003cp\u003eIt is rated at 30 GPM, with 4 models from 1\/2 to 1-1\/2 HP for deeper settings. The pump fits a 3 in or larger well and suits household supply, light commercial service, irrigation and tank filling or emptying.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eConstant pressure.\u003c\/strong\u003e The CU 302 changes pump speed, 3,000 to 10,700 rpm, to hold its setpoint (factory 50 PSI, adjustable 20 to 100 PSI in 5 PSI steps). It works with a 2 gal diaphragm tank instead of a large pressure tank.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBuilt-in protection.\u003c\/strong\u003e Dry-run, over- and undervoltage (cuts out below 150 V and above 315 V and restarts by itself), overload, locked-rotor and over-temperature protection are built into the motor. No protection relay or motor starter needed.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSoft start, no start limit.\u003c\/strong\u003e The motor ramps up in about 3 seconds and has no limit on starts or stops per hour.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSand-tolerant hydraulics.\u003c\/strong\u003e Floating impellers each run on their own tungsten carbide \/ ceramic bearing; a top bearing protects pump and motor against upthrust at start-up.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall it any way up.\u003c\/strong\u003e Vertical, horizontal or anywhere between, with a built-in spring check valve; use a flow sleeve when horizontal.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"background:#FFFFFF;border:1px solid #C7CBD1;border-top:3px solid #B3122A;padding:12px 16px 12px;margin:16px 0 4px;font-size:13.5px;line-height:1.55;color:#4A4A4F\"\u003e\n\u003cdiv style=\"font-family:Arial Black,Arial,sans-serif;font-size:11px;letter-spacing:1.2px;text-transform:uppercase;color:#B3122A;margin-bottom:8px\"\u003eWhat Ships and What It Needs to Run\u003c\/div\u003e\n\u003cp style=\"margin:0 0 6px\"\u003e\u003cstrong style=\"color:#B3122A\"\u003eIncluded:\u003c\/strong\u003e the pump and its 3 in SQE motor, assembled, with a built-in check valve, plus a 5 ft, 14 AWG motor cable with plug that you press onto the motor socket and secure with four screws. The controller is \u003cstrong\u003enot\u003c\/strong\u003e in the box.\u003c\/p\u003e\n\u003cp style=\"margin:0 0 6px\"\u003e\u003cstrong style=\"color:#B3122A\"\u003eFor constant pressure: CU 302 and a pressure sensor, ordered separately.\u003c\/strong\u003e Use the \u003ca href=\"\/products\/grundfos-cu-302-constant-pressure-control\"\u003eGrundfos CU 302 Constant Pressure Control\u003c\/a\u003e, sold with or without its 0-120 PSI pressure sensor, plus a 2 gal diaphragm tank. Variable speed needs the CU 302.\u003c\/p\u003e\n\u003cp style=\"margin:0 0 6px\"\u003e\u003cstrong style=\"color:#B3122A\"\u003eWithout a controller:\u003c\/strong\u003e Grundfos states the motor can be connected directly to the main breaker and started by a pressure switch rated for the pump's current; it then runs at full speed, like an SQ, with no constant pressure.\u003c\/p\u003e\n\u003cp style=\"margin:0 0 6px\"\u003e\u003cstrong style=\"color:#B3122A\"\u003eNever connect:\u003c\/strong\u003e a capacitor, a conventional control box or an external frequency drive.\u003c\/p\u003e\n\u003cp style=\"margin:0\"\u003e\u003cstrong style=\"color:#B3122A\"\u003eDrop cable and splice kit:\u003c\/strong\u003e sized to your setting depth (cable table under Models \u0026amp; Performance) and ordered separately. A replacement motor cable is on our \u003ca href=\"\/products\/grundfos-sq-sqe-pump-accessories\"\u003eGrundfos SQ and SQE Pump Accessories\u003c\/a\u003e listing; you do not need one for a new pump.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"background:#E1E3E6;border-left:3px solid #B8BDC4;padding:8px 14px;font-size:11.5px;color:#4A4A4F;margin-top:14px;line-height:1.5\"\u003eGenuine Grundfos equipment, factory-new in original packaging — sold and supported by Watermain Supply, an independent industrial supplier.\u003c\/div\u003e\n\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eWarranty\u003c\/div\u003e\n\u003cdiv class=\"gs-lead\"\u003e\u003cp\u003e24 months from date of installation, but not more than 30 months from date of manufacture. In Grundfos's words, products are “warranted to the original user only to be free of defects in material and workmanship”; the full terms are in the installation and operating instructions on the Data Sheet tab.\u003c\/p\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eSpecifications\u003c\/div\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated flow\u003c\/td\u003e\n\u003ctd\u003e30 GPM nominal; working range 8-42 GPM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHorsepower\u003c\/td\u003e\n\u003ctd\u003e1\/2 to 1-1\/2 HP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply\u003c\/td\u003e\n\u003ctd\u003e1 x 100-115 V (1\/2 HP only) or 1 x 200-240 V, 60 Hz; 2-wire plus ground\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor\u003c\/td\u003e\n\u003ctd\u003eMSE 3 permanent-magnet motor with built-in electronics, 3,000 to 10,700 rpm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl\u003c\/td\u003e\n\u003ctd\u003eCU 302 over the power leads (GENIbus); Bluetooth to Grundfos GO and the Grundfos HOME app\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection\u003c\/td\u003e\n\u003ctd\u003eDry run, overvoltage and undervoltage (cuts out below 150 V and above 315 V), overload, locked rotor, over-temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStarting\u003c\/td\u003e\n\u003ctd\u003eSoft start, run-up maximum 3 seconds; no limit on starts or stops per hour\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor cable\u003c\/td\u003e\n\u003ctd\u003e3-wire, 14 AWG XLPE, 5 ft, with plug\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDischarge\u003c\/td\u003e\n\u003ctd\u003e1-1\/2 in NPT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWell diameter\u003c\/td\u003e\n\u003ctd\u003e3 in minimum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSetting depth\u003c\/td\u003e\n\u003ctd\u003eUp to 500 ft below the static water level; at least 20 in below the pumping water level\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePumped liquid\u003c\/td\u003e\n\u003ctd\u003eClean water, pH 5 to 9, up to 86°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGenerator\u003c\/td\u003e\n\u003ctd\u003eOutput at least the motor input power (P1) plus 50% recommended, never less than P1 plus 10%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"font-size:12.5px;color:#9B9EA3;margin-top:8px;line-height:1.55\"\u003eSource: Grundfos SQ, SQE, SmartFlo and SP data booklet (North America, 60 Hz), technical data.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eModels \u0026amp; Performance — Will It Do What You Need?\u003c\/div\u003e\n\u003cp style=\"font-size:13.5px;margin-bottom:10px\"\u003ePick a model whose head at your flow covers the pumping water level, the pressure you need at the surface (2.31 ft per PSI) and pipe friction. Then check the set-pressure table for what it delivers at your depth.\u003c\/p\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003cth\u003eHP\u003c\/th\u003e\n\u003cth\u003e0 GPM (Shut-off)\u003c\/th\u003e\n\u003cth\u003e7.9 GPM\u003c\/th\u003e\n\u003cth\u003e19.7 GPM\u003c\/th\u003e\n\u003cth\u003e30 GPM (Rated)\u003c\/th\u003e\n\u003cth\u003e39.4 GPM (Max)\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e30 SQE05-40\u003c\/td\u003e\n\u003ctd\u003e1\/2\u003c\/td\u003e\n\u003ctd\u003e67\u003c\/td\u003e\n\u003ctd\u003e63\u003c\/td\u003e\n\u003ctd\u003e50\u003c\/td\u003e\n\u003ctd\u003e33\u003c\/td\u003e\n\u003ctd\u003e5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e30 SQE07-90\u003c\/td\u003e\n\u003ctd\u003e3\/4\u003c\/td\u003e\n\u003ctd\u003e138\u003c\/td\u003e\n\u003ctd\u003e130\u003c\/td\u003e\n\u003ctd\u003e110\u003c\/td\u003e\n\u003ctd\u003e82\u003c\/td\u003e\n\u003ctd\u003e33\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e30 SQE10-130\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003ctd\u003e208\u003c\/td\u003e\n\u003ctd\u003e196\u003c\/td\u003e\n\u003ctd\u003e170\u003c\/td\u003e\n\u003ctd\u003e126\u003c\/td\u003e\n\u003ctd\u003e61\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e30 SQE15-170\u003c\/td\u003e\n\u003ctd\u003e1-1\/2\u003c\/td\u003e\n\u003ctd\u003e266\u003c\/td\u003e\n\u003ctd\u003e253\u003c\/td\u003e\n\u003ctd\u003e225\u003c\/td\u003e\n\u003ctd\u003e176\u003c\/td\u003e\n\u003ctd\u003e91\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"font-size:12.5px;color:#9B9EA3;margin-top:8px;line-height:1.55\"\u003eTotal head in feet. The shut-off and flow columns are read from the Grundfos 60 Hz curves for the 30 SQ, SQE (SQ and SQE share one curve, the SQE at its 10,700 rpm top speed), digitized from the published curve charts in the Grundfos SQ, SQE, SmartFlo and SP data booklet, at the nearest published point and rounded down. The (Rated) column is the head Grundfos prints at 30 GPM in its system sizing matrix, verbatim; the number in the model name is a nominal figure and reads lower on some models. 1 ft of head = 0.433 PSI. Full curves are in the product images and on the Data Sheet tab.\u003c\/p\u003e\n\u003cp style=\"font-size:13.5px;margin-bottom:10px;margin-top:18px\"\u003e\u003cstrong\u003eWhat It Delivers at Your Set Pressure\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdetails open style=\"margin:8px 0;border-top:3px solid #B3122A;padding:0 4px 6px\"\u003e\u003csummary style=\"cursor:pointer;padding:8px 0;font-weight:bold;color:#4A4A4F\"\u003eOutput at 50 and 60 PSI · 1 to 1-1\/2 HP · 2 models · depths 20 to 140 ft\u003c\/summary\u003e\n\u003cp\u003e\u003cstrong\u003eGPM at 50 PSI\u003c\/strong\u003e (CU 302 factory setpoint), by depth to water\u003c\/p\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003cth\u003e20 ft\u003c\/th\u003e\n\u003cth\u003e40 ft\u003c\/th\u003e\n\u003cth\u003e60 ft\u003c\/th\u003e\n\u003cth\u003e80 ft\u003c\/th\u003e\n\u003cth\u003e100 ft\u003c\/th\u003e\n\u003cth\u003e120 ft\u003c\/th\u003e\n\u003cth\u003e140 ft\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e30 SQE10-130\u003c\/td\u003e\n\u003ctd\u003e28.9\u003c\/td\u003e\n\u003ctd\u003e24.6\u003c\/td\u003e\n\u003ctd\u003e18.7\u003c\/td\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e30 SQE15-170*\u003c\/td\u003e\n\u003ctd\u003e35\u003c\/td\u003e\n\u003ctd\u003e32.5\u003c\/td\u003e\n\u003ctd\u003e30\u003c\/td\u003e\n\u003ctd\u003e26.5\u003c\/td\u003e\n\u003ctd\u003e22\u003c\/td\u003e\n\u003ctd\u003e16.5\u003c\/td\u003e\n\u003ctd\u003e6.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp\u003e\u003cstrong\u003eGPM at 60 PSI\u003c\/strong\u003e (setpoint), by depth to water\u003c\/p\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003cth\u003e20 ft\u003c\/th\u003e\n\u003cth\u003e40 ft\u003c\/th\u003e\n\u003cth\u003e60 ft\u003c\/th\u003e\n\u003cth\u003e80 ft\u003c\/th\u003e\n\u003cth\u003e100 ft\u003c\/th\u003e\n\u003cth\u003e120 ft\u003c\/th\u003e\n\u003cth\u003e140 ft\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e30 SQE10-130\u003c\/td\u003e\n\u003ctd\u003e23.7\u003c\/td\u003e\n\u003ctd\u003e17.8\u003c\/td\u003e\n\u003ctd\u003e7.6\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e30 SQE15-170*\u003c\/td\u003e\n\u003ctd\u003e32\u003c\/td\u003e\n\u003ctd\u003e29.5\u003c\/td\u003e\n\u003ctd\u003e26\u003c\/td\u003e\n\u003ctd\u003e21.5\u003c\/td\u003e\n\u003ctd\u003e15.5\u003c\/td\u003e\n\u003ctd\u003e5\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cp style=\"font-size:12.5px;color:#9B9EA3;margin-top:8px;line-height:1.55\"\u003eFrom the Grundfos 3 in SQ sizing charts (pp. 44), verbatim: gallons per minute at the pressure shown and the depth to pumping water level. The SQE runs on the same curve as the SQ at full speed, so each cell is the most the SQE delivers while the CU 302 holds that pressure. Riser and pipe friction are not included. A dash means Grundfos prints no figure: on the shallow side the flow is past the chart range, on the deep side the pump cannot hold that pressure. Not shown: 30 SQE05-40, 30 SQE07-90, which Grundfos charts below 50 PSI at every depth; use them on a lower setpoint or for transfer duty. * 30 SQE15-170: Grundfos prints no sizing chart for this model, so its row is calculated, not printed: the flow where the published curve meets the depth plus 116 ft (50 PSI) or 139 ft (60 PSI), interpolated between published points and rounded down to 0.5 GPM.\u003c\/p\u003e\n\u003cp style=\"font-size:13.5px;margin-bottom:10px;margin-top:18px\"\u003e\u003cstrong\u003eDrop Cable Size\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdetails style=\"margin:8px 0;border-top:3px solid #B3122A;padding:0 4px 6px\"\u003e\u003csummary style=\"cursor:pointer;padding:8px 0;font-weight:bold;color:#4A4A4F\"\u003eDrop cable size by distance · copper, 60 Hz\u003c\/summary\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eVolts\u003c\/th\u003e\n\u003cth\u003eHP\u003c\/th\u003e\n\u003cth\u003eAmps\u003c\/th\u003e\n\u003cth\u003e14 AWG\u003c\/th\u003e\n\u003cth\u003e12 AWG\u003c\/th\u003e\n\u003cth\u003e10 AWG\u003c\/th\u003e\n\u003cth\u003e8 AWG\u003c\/th\u003e\n\u003cth\u003e6 AWG\u003c\/th\u003e\n\u003cth\u003e4 AWG\u003c\/th\u003e\n\u003cth\u003e2 AWG\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e115\u003c\/td\u003e\n\u003ctd\u003e1\/2\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003ctd\u003e140\u003c\/td\u003e\n\u003ctd\u003e220\u003c\/td\u003e\n\u003ctd\u003e360\u003c\/td\u003e\n\u003ctd\u003e550\u003c\/td\u003e\n\u003ctd\u003e880\u003c\/td\u003e\n\u003ctd\u003e1390\u003c\/td\u003e\n\u003ctd\u003e2260\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e230\u003c\/td\u003e\n\u003ctd\u003e1\/2\u003c\/td\u003e\n\u003ctd\u003e5.2\u003c\/td\u003e\n\u003ctd\u003e640\u003c\/td\u003e\n\u003ctd\u003e1000\u003c\/td\u003e\n\u003ctd\u003e1660\u003c\/td\u003e\n\u003ctd\u003e2250\u003c\/td\u003e\n\u003ctd\u003e4060\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e230\u003c\/td\u003e\n\u003ctd\u003e3\/4\u003c\/td\u003e\n\u003ctd\u003e8.4\u003c\/td\u003e\n\u003ctd\u003e400\u003c\/td\u003e\n\u003ctd\u003e620\u003c\/td\u003e\n\u003ctd\u003e1030\u003c\/td\u003e\n\u003ctd\u003e1580\u003c\/td\u003e\n\u003ctd\u003e2510\u003c\/td\u003e\n\u003ctd\u003e3970\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e230\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003ctd\u003e11.2\u003c\/td\u003e\n\u003ctd\u003e300\u003c\/td\u003e\n\u003ctd\u003e460\u003c\/td\u003e\n\u003ctd\u003e770\u003c\/td\u003e\n\u003ctd\u003e1190\u003c\/td\u003e\n\u003ctd\u003e1890\u003c\/td\u003e\n\u003ctd\u003e2980\u003c\/td\u003e\n\u003ctd\u003e4850\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e230\u003c\/td\u003e\n\u003ctd\u003e1-1\/2\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003ctd\u003e280\u003c\/td\u003e\n\u003ctd\u003e430\u003c\/td\u003e\n\u003ctd\u003e720\u003c\/td\u003e\n\u003ctd\u003e1110\u003c\/td\u003e\n\u003ctd\u003e1760\u003c\/td\u003e\n\u003ctd\u003e2780\u003c\/td\u003e\n\u003ctd\u003e4530\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"font-size:12.5px;color:#9B9EA3;margin-top:8px;line-height:1.55\"\u003eMaximum length in feet from the motor to the service entrance, copper wire, 9% voltage drop, from the Grundfos SQ, SQE installation and operating instructions and data booklet. A dash means not listed.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdiv style=\"display:flex;flex-wrap:wrap;gap:10px;margin:22px 0 4px\"\u003e\n\u003ca href=\"\/pages\/submersible-well-pump-sizing-calculator\" style=\"flex:1 1 200px;text-align:center;display:block;background:#B3122A;color:#ffffff;font-family:Arial Black,Arial,sans-serif;font-size:12px;text-transform:uppercase;letter-spacing:1.2px;padding:11px 18px;text-decoration:none\"\u003eSubmersible Calculator\u003c\/a\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eBefore You Buy — The Limits That Decide the Fit\u003c\/div\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eCheck\u003c\/th\u003e\n\u003cth\u003eWhat to confirm\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eWell size\u003c\/td\u003e\n\u003ctd\u003e3 in or larger casing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWater\u003c\/td\u003e\n\u003ctd\u003eClean water, pH 5 to 9, up to 86°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSetting\u003c\/td\u003e\n\u003ctd\u003eNo deeper than 500 ft below the static water level, and at least 20 in below the pumping water level\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower\u003c\/td\u003e\n\u003ctd\u003e1\/2 HP models come in 115 V or 230 V versions (different part numbers, not field-convertible); 3\/4 HP and up are 230 V only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWiring\u003c\/td\u003e\n\u003ctd\u003eCU 302 for constant pressure; or a pressure switch rated for the pump's current. Never a capacitor, control box or external drive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHorizontal install\u003c\/td\u003e\n\u003ctd\u003eUse the SQ\/SQE flow sleeve (on our \u003ca href=\"\/products\/grundfos-sq-sqe-pump-accessories\"\u003eGrundfos SQ and SQE Pump Accessories\u003c\/a\u003e listing) to keep water moving past the motor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGenerator\u003c\/td\u003e\n\u003ctd\u003eAt least the motor input power plus 50% (minimum plus 10%)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eMaterials of Construction\u003c\/div\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003ePart\u003c\/th\u003e\n\u003cth\u003eMaterial\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePump sleeve, outlet chamber, cable guard\u003c\/td\u003e\n\u003ctd\u003eAISI 304 stainless steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eImpellers, chambers, guide vanes, valve casing\u003c\/td\u003e\n\u003ctd\u003ePolyamide (30% glass-fibre reinforced)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eImpeller bearings\u003c\/td\u003e\n\u003ctd\u003eTungsten carbide \/ ceramic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShaft\u003c\/td\u003e\n\u003ctd\u003eAISI 304 stainless steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eValve seat, seals\u003c\/td\u003e\n\u003ctd\u003eNBR rubber\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor stator, rotor, top cover\u003c\/td\u003e\n\u003ctd\u003eAISI 304 stainless steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor bearings\u003c\/td\u003e\n\u003ctd\u003eSilicon carbide \/ tungsten carbide (coated); carbon thrust bearing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"font-size:12.5px;color:#9B9EA3;margin-top:8px;line-height:1.55\"\u003eSource: Grundfos SQ, SQE, SmartFlo and SP data booklet, construction.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"gs-contact\"\u003eFor engineering-led sizing and selection support or a factory submittal, email \u003ca href=\"mailto:sales@watermainsupply.com\"\u003esales@watermainsupply.com\u003c\/a\u003e or call \u003ca href=\"tel:18885104036\"\u003e1-888.510.4036\u003c\/a\u003e.\u003cbr\u003e© Watermain Supply — A division of E4 Industrial LLC\u003c\/div\u003e\n\n\u003c\/div\u003e\n\u003ch5\u003eData Sheet\u003c\/h5\u003e\u003cdiv class=\"gs\"\u003e\u003cdiv class=\"gs-dl\"\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0264\/1913\/4527\/files\/SQ_SQE_us.pdf?v=1788826864\" target=\"_blank\" rel=\"noopener\"\u003eSQ, SQE Installation and Operating Instructions\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0264\/1913\/4527\/files\/SQE_Brochure_2.pdf?v=1788826864\" target=\"_blank\" rel=\"noopener\"\u003eGrundfos SQE Constant Pressure Groundwater System Brochure\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0264\/1913\/4527\/files\/SQ_SQE_Brochure.pdf?v=1788826865\" target=\"_blank\" rel=\"noopener\"\u003eGrundfos SQ\/SQE Range Brochure\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0264\/1913\/4527\/files\/SQ_Performance_Curves.pdf?v=1788826864\" target=\"_blank\" rel=\"noopener\"\u003e3 in SQ Sizing Guide — Curves and Sizing Charts\u003c\/a\u003e\n\u003c\/div\u003e\u003c\/div\u003e\u003ch5\u003eVideos\u003c\/h5\u003e\u003cdiv class=\"gs\"\u003e\u003cdiv class=\"gs-sec\" style=\"margin-top:6px\"\u003e\n\u003cdiv style=\"display:grid;grid-template-columns:repeat(auto-fit,minmax(300px,1fr));gap:20px\"\u003e\n\u003cdiv\u003e\n\u003cdiv style=\"position:relative;width:100%;padding-top:56.25%;background:#4A4A4F\"\u003e\u003ciframe src=\"https:\/\/www.youtube.com\/embed\/_Kn3OVDRZOE?si=3DToNwIsKFSrV9Bt\" title=\"SQ and SQE: Constant Pressure Pump Overview\" loading=\"lazy\" frameborder=\"0\" style=\"position:absolute;top:0;left:0;width:100%;height:100%;border:0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share\" referrerpolicy=\"strict-origin-when-cross-origin\" allowfullscreen\u003e\u003c\/iframe\u003e\u003c\/div\u003e\n\u003cp style=\"font-family:Arial,Helvetica,sans-serif;font-size:13px;line-height:1.45;color:#4A4A4F;margin:8px 0 0\"\u003eSQ and SQE: Constant Pressure Pump Overview \u003cspan style=\"color:#9B9EA3\"\u003e(4:02)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cdiv style=\"position:relative;width:100%;padding-top:56.25%;background:#4A4A4F\"\u003e\u003ciframe src=\"https:\/\/www.youtube.com\/embed\/lHPdSndKQqs?si=tktPTsRHA2Z-H07V\" title=\"Installing a Grundfos SQE Constant Pressure System\" loading=\"lazy\" frameborder=\"0\" style=\"position:absolute;top:0;left:0;width:100%;height:100%;border:0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share\" referrerpolicy=\"strict-origin-when-cross-origin\" allowfullscreen\u003e\u003c\/iframe\u003e\u003c\/div\u003e\n\u003cp style=\"font-family:Arial,Helvetica,sans-serif;font-size:13px;line-height:1.45;color:#4A4A4F;margin:8px 0 0\"\u003eInstalling a Grundfos SQE Constant Pressure System \u003cspan style=\"color:#9B9EA3\"\u003e(5:22)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cdiv style=\"position:relative;width:100%;padding-top:56.25%;background:#4A4A4F\"\u003e\u003ciframe src=\"https:\/\/www.youtube.com\/embed\/U4gomM0GLr0?si=CP3NowIBbbzTzjEP\" title=\"Grundfos SQE Pump Restores Clean Water to a California Family\" loading=\"lazy\" frameborder=\"0\" style=\"position:absolute;top:0;left:0;width:100%;height:100%;border:0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share\" referrerpolicy=\"strict-origin-when-cross-origin\" allowfullscreen\u003e\u003c\/iframe\u003e\u003c\/div\u003e\n\u003cp style=\"font-family:Arial,Helvetica,sans-serif;font-size:13px;line-height:1.45;color:#4A4A4F;margin:8px 0 0\"\u003eGrundfos SQE Pump Restores Clean Water to a California Family \u003cspan style=\"color:#9B9EA3\"\u003e(6:42)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp style=\"font-family:Arial,Helvetica,sans-serif;font-size:12px;color:#9B9EA3;margin:16px 0 0\"\u003eVideos produced by Grundfos and hosted on YouTube.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/div\u003e\u003ch5\u003eGrundfos HOME App\u003c\/h5\u003e\u003cdiv class=\"gs\"\u003e\u003cdiv class=\"gs-sec\" style=\"margin-top:6px\"\u003e\n\u003cdiv class=\"gs-h\"\u003eSet Up \u0026amp; Monitor From Your Phone\u003c\/div\u003e\n\u003cdiv class=\"gs-lead\"\u003e\u003cp\u003eThe free Grundfos HOME app gives you full control of your water system from an iOS or Android phone. Pair an SQE with a CU 302 control unit and the app reports pump information around the clock, sends alert notifications on important events so you can act before the water goes off, and carries a built-in watering calendar with an internal clock so irrigation routines run to schedule without a timer. Installer details are stored in the app, so whoever set the system up is one tap away.\u003c\/p\u003e\u003c\/div\u003e\n\u003cdiv style=\"margin-top:16px\"\u003e\n\u003ca href=\"https:\/\/apps.apple.com\/us\/app\/grundfos-home\/id1592451846\" target=\"_blank\" rel=\"noopener\" style=\"display:inline-block;background:#B3122A;color:#fff!important;font-family:Arial Black,Arial,sans-serif;font-size:13px;letter-spacing:1px;text-transform:uppercase;text-decoration:none;padding:12px 24px;border-radius:999px;margin:0 10px 10px 0\"\u003eDownload for iOS\u003c\/a\u003e\u003ca href=\"https:\/\/play.google.com\/store\/apps\/details?id=com.grundfos.home\u0026amp;pcampaignid=web_share\" target=\"_blank\" rel=\"noopener\" style=\"display:inline-block;background:#4A4A4F;color:#fff!important;font-family:Arial Black,Arial,sans-serif;font-size:13px;letter-spacing:1px;text-transform:uppercase;text-decoration:none;padding:12px 24px;border-radius:999px;margin:0 10px 10px 0\"\u003eDownload for Android\u003c\/a\u003e\n\u003c\/div\u003e\n\u003cp style=\"font-size:12px;color:#9B9EA3;margin-top:14px;line-height:1.6\"\u003eGrundfos HOME is a free app from Grundfos Holding A\/S. It connects through the CU 302 control unit, which is required and is sold separately, and Bluetooth must be enabled on the CU 302 operating panel before pairing. Installers and service technicians use a separate free Grundfos app, Grundfos GO, as the commissioning and diagnostic tool; ask us for the link if you need it.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/div\u003e\u003c!-- \/TABS --\u003e","brand":"Grundfos","offers":[{"title":"1\/2 HP - 3 in Motor \/ 115V 1Ph 2-Wire \/ 30 SQE05-40 - 33 ft at 30 GPM","offer_id":47457480442031,"sku":"96160215","price":1458.25,"currency_code":"USD","in_stock":true},{"title":"1\/2 HP - 3 in Motor \/ 230V 1Ph 2-Wire \/ 30 SQE05-40 - 33 ft at 30 GPM","offer_id":47457480474799,"sku":"96160202","price":1458.25,"currency_code":"USD","in_stock":true},{"title":"3\/4 HP - 3 in Motor \/ 230V 1Ph 2-Wire \/ 30 SQE07-90 - 82 ft at 30 GPM","offer_id":47457480507567,"sku":"96160203","price":1777.23,"currency_code":"USD","in_stock":true},{"title":"1 HP - 3 in Motor \/ 230V 1Ph 2-Wire \/ 30 SQE10-130 - 126 ft at 30 GPM","offer_id":47457480540335,"sku":"96160204","price":2016.61,"currency_code":"USD","in_stock":true},{"title":"1-1\/2 HP - 3 in Motor \/ 230V 1Ph 2-Wire \/ 30 SQE15-170 - 176 ft at 30 GPM","offer_id":47457480573103,"sku":"93001562","price":2099.96,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0264\/1913\/4527\/files\/Grundfos_SQE_Submersible_Pump.webp?v=1788826893"},{"product_id":"grundfos-cu-302-constant-pressure-control","title":"Grundfos CU 302 Constant Pressure Control","description":"\u003c!-- TABS --\u003e\u003ch5\u003eDescription\u003c\/h5\u003e\u003cdiv class=\"gs\"\u003e\n\u003cdiv class=\"gs-head\"\u003e\n\u003cdiv class=\"gs-eyebrow\"\u003eGRUNDFOS · CONSTANT PRESSURE CONTROL UNIT\u003c\/div\u003e\n\u003cdiv class=\"gs-title\"\u003eCU 302\u003c\/div\u003e\n\u003cdiv class=\"gs-sub\"\u003eControl and communication unit for Grundfos SQE submersible pumps. Talks to the pump over the existing power leads — no extra wires down the well — and varies pump speed to hold a constant pressure from a trickle to full flow. Pre-set for constant pressure, 20 to 100 PSI, with a 50 PSI factory setpoint.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"gs-badges\"\u003e\n\u003cdiv class=\"gs-badge\"\u003eConstant Pressure 20-100 PSI\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003e50 PSI Factory Setpoint\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003e90-240 VAC, 12.5 A\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003eType 1 \/ Type 3R UL\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003eBluetooth to Grundfos GO\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003ePower Line Communication\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eOverview\u003c\/div\u003e\n\u003cdiv class=\"gs-lead\"\u003e\n\u003cp\u003eCU 302 is a control and communication unit specially developed for the SQE submersible pumps in constant-pressure applications. It is intended for controlling and monitoring SQE pumps using power line communication, so the control unit communicates with the pump via the power cable and nothing additional is run down the borehole.\u003c\/p\u003e\n\u003cp\u003eThe controller operates according to the water pressure measured by a pressure sensor in the installation. When water is consumed, the system detects flow together with pressure change; the controller starts the pump, and pump performance and water flow are controlled by changing the pump speed. The system maintains a constant pressure within the maximum pump performance in spite of varying water consumption.\u003c\/p\u003e\n\u003cp\u003eThe factory setup is constant pressure over 2 to 5 bar (20 to 100 PSI) with a setpoint of 3 bar (50 PSI), CIO 1 configured for an analog sensor and CIO 2 for digital outputs; when the pump is running the output changes contact position. Input signals can be analog sensors or digital switches, and the controller can be used in a range of other applications by changing its configuration: level control filling, level control emptying, pressure control on a digital or an analog input, pump out, and pump monitoring.\u003c\/p\u003e\n\u003cp\u003eOperating indication sits on the front of the controller — power on, pump running, and the Grundfos Eye showing pump status — alongside alarm and warning indication. CU 302 reports dry running and service-needed conditions including no contact to the pump, overvoltage, overtemperature and overload. In a constant-pressure installation it works with a 2 gal (8 litre) diaphragm tank rather than a conventional pressure tank, because the pump follows demand instead of cycling between two switch settings.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"background:#FFFFFF;border:1px solid #C7CBD1;border-top:3px solid #B3122A;padding:12px 16px 12px;margin:16px 0 4px;font-size:13.5px;line-height:1.55;color:#4A4A4F\"\u003e\n\u003cdiv style=\"font-family:Arial Black,Arial,sans-serif;font-size:11px;letter-spacing:1.2px;text-transform:uppercase;color:#B3122A;margin-bottom:8px\"\u003eWhat Ships and What It Needs to Run\u003c\/div\u003e\n\u003cp style=\"margin:0 0 6px\"\u003e\u003cstrong style=\"color:#B3122A\"\u003eIncluded:\u003c\/strong\u003e the CU 302 controller with its quick guide and cable-gland accessories; the \"With Pressure Sensor\" version adds the 0-120 PSI pressure sensor.\u003c\/p\u003e\n\u003cp style=\"margin:0 0 6px\"\u003e\u003cstrong style=\"color:#B3122A\"\u003eRequired:\u003c\/strong\u003e a \u003ca href=\"\/products\/grundfos-10-sqe-submersible-well-pump\"\u003eGrundfos SQE pump\u003c\/a\u003e (the CU 302 runs SQE pumps only, over the power leads), a 2 gal diaphragm tank, and a 90-240 VAC supply. Bought without the sensor, it needs the \u003ca href=\"\/products\/grundfos-sq-sqe-pump-accessories\"\u003epressure transducer (0-120 PSI, 92506685)\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp style=\"margin:0\"\u003e\u003cstrong style=\"color:#B3122A\"\u003eSetup:\u003c\/strong\u003e factory setpoint 50 PSI, adjustable 20 to 100 PSI in 5 PSI steps at the keypad, or with Grundfos GO and the Grundfos HOME app.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background:#E1E3E6;border-left:3px solid #B8BDC4;padding:8px 14px;font-size:11.5px;color:#4A4A4F;margin-top:14px;line-height:1.5\"\u003eGenuine Grundfos equipment, factory-new in original packaging — sold and supported by Watermain Supply, an independent industrial supplier.\u003c\/div\u003e\n\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eWarranty\u003c\/div\u003e\n\u003cdiv class=\"gs-lead\"\u003e\u003cp\u003e24 months from date of installation, but not more than 30 months from date of manufacture. In Grundfos's words, products are “warranted to the original user only to be free of defects in material and workmanship”; the full terms are in the installation and operating instructions on the Data Sheet tab.\u003c\/p\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eModels \u0026amp; Configurations\u003c\/div\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eConfiguration\u003c\/th\u003e\n\u003cth\u003ePressure sensor\u003c\/th\u003e\n\u003cth\u003eUnits\u003c\/th\u003e\n\u003cth\u003eApproval\u003c\/th\u003e\n\u003cth\u003ePart No.\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eCU 302 UL, complete\u003c\/td\u003e\n\u003ctd\u003eNot included\u003c\/td\u003e\n\u003ctd\u003ePSI\u003c\/td\u003e\n\u003ctd\u003eUL\u003c\/td\u003e\n\u003ctd\u003e92799799\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCU 302 UL with PSI sensor\u003c\/td\u003e\n\u003ctd\u003eIncluded\u003c\/td\u003e\n\u003ctd\u003ePSI\u003c\/td\u003e\n\u003ctd\u003eUL\u003c\/td\u003e\n\u003ctd\u003e92817764\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"font-size:12.5px;color:#9B9EA3;margin-top:8px;line-height:1.55\"\u003eBoth variants are the North American UL build reading in PSI. Grundfos also lists bar-reading CE variants — 92799797 without sensor and 92817763 with sensor — which are the CE-market builds and are not the ones to order in North America. A constant-pressure installation needs a sensor: order the with-sensor part number, or the without-sensor part number plus a transducer.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eKey Features\u003c\/div\u003e\n\u003cdiv class=\"gs-lead\"\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePre-set for constant pressure\u003c\/strong\u003e — out of the box it holds a setpoint over 20 to 100 PSI, and it also supports level control, pressure control, pump out and pump monitoring by changing the configuration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower line communication\u003c\/strong\u003e — GENIbus to the SQE over the two existing power leads, so no signal cable runs down the well.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConfigurable input and output\u003c\/strong\u003e — two CIO channels taking analog sensors or digital switches; analog in 0-10 V, 0-5 V, 0.5-3.5 V, 0-20 mA or 4-20 mA, analog out 0-10 V, 0-20 mA or 4-20 mA.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManual and automatic control\u003c\/strong\u003e of the pump from the front panel, with a STOP button and keypad lockout.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrundfos Eye status indicator\u003c\/strong\u003e plus alarm and warning indication, including dry running and no contact to the pump.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBluetooth pairing with Grundfos GO\u003c\/strong\u003e for setpoint, control mode, sensor range, scheduling, the installation log and live metrics.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOut-of-range sensor detection\u003c\/strong\u003e — a warning or alarm is raised when the input signal falls under or over the configured range, so a failed transducer shows up as a fault rather than a wrong pressure.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eField-updatable software\u003c\/strong\u003e and a replaceable battery.\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eSpecifications\u003c\/div\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply voltage\u003c\/td\u003e\n\u003ctd\u003e90-240 VAC -10 % \/ +6 %, PE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency\u003c\/td\u003e\n\u003ctd\u003e50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated current\u003c\/td\u003e\n\u003ctd\u003eMaximum 12.5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMains fuses \/ backup fuse\u003c\/td\u003e\n\u003ctd\u003eMaximum 16 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower consumption\u003c\/td\u003e\n\u003ctd\u003eMaximum 25 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOvervoltage category\u003c\/td\u003e\n\u003ctd\u003eIII\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eField wiring\u003c\/td\u003e\n\u003ctd\u003eMinimum 20 AWG rated 140 °F or higher. Copper, copper-clad aluminum or aluminum conductors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog input\u003c\/td\u003e\n\u003ctd\u003e0-10 V, 0-5 V or 0.5-3.5 V at 100 k\u0026amp;ohm; load; 0-20 mA or 4-20 mA at maximum 2 V drop. Under-range and over-range raise a warning or alarm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog output\u003c\/td\u003e\n\u003ctd\u003e0-10 V at maximum 20 mA; 0-20 mA or 4-20 mA into 500 \u0026amp;ohm; or less\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDefault control mode\u003c\/td\u003e\n\u003ctd\u003eConstant pressure, 2-5 bar (20-100 PSI), setpoint 3 bar (50 PSI)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOther control modes\u003c\/td\u003e\n\u003ctd\u003eLevel control filling, level control emptying, pressure control on digital input, pressure control on analog input, pump out, pump monitoring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure sensor range\u003c\/td\u003e\n\u003ctd\u003e0-6 bar (0-120 PSI) analog\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransceiver\u003c\/td\u003e\n\u003ctd\u003eRS-485\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtocol\u003c\/td\u003e\n\u003ctd\u003eGENIbus over the pump power cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWireless\u003c\/td\u003e\n\u003ctd\u003eBluetooth to the Grundfos GO app\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure class\u003c\/td\u003e\n\u003ctd\u003eType 1 \/ Type 3R on the UL version (IP55 on the CE version)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient temperature, operating\u003c\/td\u003e\n\u003ctd\u003e-4 °F to +122 °F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient temperature, storage\u003c\/td\u003e\n\u003ctd\u003e-22 °F to +140 °F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative air humidity\u003c\/td\u003e\n\u003ctd\u003e5-95 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e9.1 in high x 6.3 in wide x 3.8 in deep\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e2.69 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMarking\u003c\/td\u003e\n\u003ctd\u003eUL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRadio noise\u003c\/td\u003e\n\u003ctd\u003eTested to EN 55014 and EN 55014-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eApplications\u003c\/div\u003e\n\u003cdiv class=\"gs-lead\"\u003e\n\u003cul\u003e\n\u003cli\u003eConstant-pressure residential water supply from a well, with an SQE pump and a 2 gal diaphragm tank\u003c\/li\u003e\n\u003cli\u003eConstant-pressure irrigation\u003c\/li\u003e\n\u003cli\u003eMaintaining a constant water table\u003c\/li\u003e\n\u003cli\u003eEmptying or filling a tank, and pumping from one tank to another, using level control\u003c\/li\u003e\n\u003cli\u003ePump monitoring where speed control is not wanted\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCU 302 controls Grundfos SQE pumps only. It will not control an SQ, which has no communication, and it must not be used with any pump outside the SQE range.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eOrdering Information\u003c\/div\u003e\n\u003cdiv class=\"gs-lead\"\u003e\n\u003cp\u003e\u003cstrong\u003eOrder by part number.\u003c\/strong\u003e CU 302 UL, complete, without sensor — 92799799. CU 302 UL with PSI sensor — 92817764.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRelated parts.\u003c\/strong\u003e CU 302 pressure transducer, 0-120 PSI, 1\/2 in NPT — 92506685. SQ, SQE cable kit, 14 AWG 5 ft NSF, motor model C — 97778332. SP, SQ, SQE wrench — 99588350. SQ, SQE flow sleeve, complete — 98148594.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat the installation needs.\u003c\/strong\u003e An SQE pump, a CU 302, a pressure sensor, a 2 gal diaphragm tank and a mains switch. The SQE pump is not included with the controller.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"gs-note\"\u003e\n\u003cb\u003eBefore You Order\u003c\/b\u003eCU 302 is for SQE pumps only — it cannot control an SQ, and an SQE without a CU 302 runs at fixed maximum speed like an SQ. Decide whether you need the sensor: 92817764 ships with the PSI transducer, 92799799 does not, and constant-pressure operation requires one. The controller is a Type 1 \/ Type 3R enclosure, so it mounts indoors or in a protected location, not in the weather. Wire it with minimum 20 AWG conductors rated 140 °F or higher, on a circuit protected at 16 A or less. Electrical connection should be carried out by a licensed electrician in accordance with local regulations.\u003c\/div\u003e\n\u003cdiv class=\"gs-contact\"\u003eFor engineering-led sizing and selection support or a factory submittal, email \u003ca href=\"mailto:sales@watermainsupply.com\"\u003esales@watermainsupply.com\u003c\/a\u003e or call \u003ca href=\"tel:18885104036\"\u003e1-888.510.4036\u003c\/a\u003e.\u003cbr\u003e© Watermain Supply — A division of E4 Industrial LLC\u003c\/div\u003e\n\u003c\/div\u003e\u003ch5\u003eData Sheet\u003c\/h5\u003e\u003cdiv class=\"gs\"\u003e\u003cdiv class=\"gs-dl\"\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0264\/1913\/4527\/files\/CU302_Brochure.pdf?v=1788826864\" target=\"_blank\" rel=\"noopener\"\u003eCU 302 Control Unit Brochure\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0264\/1913\/4527\/files\/CU302_installation_and_operation.pdf?v=1788826865\" target=\"_blank\" rel=\"noopener\"\u003eCU 302 Installation and Operating Instructions\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0264\/1913\/4527\/files\/CU302_Electrical_Diagram_and_Installation.pdf?v=1788826865\" target=\"_blank\" rel=\"noopener\"\u003eCU 302 Electrical Diagram and Installation\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0264\/1913\/4527\/files\/SQE_Brochure_2.pdf?v=1788826864\" target=\"_blank\" rel=\"noopener\"\u003eGrundfos SQE Constant Pressure Groundwater System Brochure\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0264\/1913\/4527\/files\/SQ_SQE_us.pdf?v=1788826864\" target=\"_blank\" rel=\"noopener\"\u003eSQ, SQE Installation and Operating Instructions\u003c\/a\u003e\n\u003c\/div\u003e\u003c\/div\u003e\u003ch5\u003eVideos\u003c\/h5\u003e\u003cdiv class=\"gs\"\u003e\u003cdiv class=\"gs-sec\" style=\"margin-top:6px\"\u003e\n\u003cdiv style=\"display:grid;grid-template-columns:repeat(auto-fit,minmax(300px,1fr));gap:20px\"\u003e\n\u003cdiv\u003e\n\u003cdiv style=\"position:relative;width:100%;padding-top:56.25%;background:#4A4A4F\"\u003e\u003ciframe src=\"https:\/\/www.youtube.com\/embed\/_Kn3OVDRZOE?si=3DToNwIsKFSrV9Bt\" title=\"SQ and SQE: Constant Pressure Pump Overview\" loading=\"lazy\" frameborder=\"0\" style=\"position:absolute;top:0;left:0;width:100%;height:100%;border:0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share\" referrerpolicy=\"strict-origin-when-cross-origin\" allowfullscreen\u003e\u003c\/iframe\u003e\u003c\/div\u003e\n\u003cp style=\"font-family:Arial,Helvetica,sans-serif;font-size:13px;line-height:1.45;color:#4A4A4F;margin:8px 0 0\"\u003eSQ and SQE: Constant Pressure Pump Overview \u003cspan style=\"color:#9B9EA3\"\u003e(4:02)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cdiv style=\"position:relative;width:100%;padding-top:56.25%;background:#4A4A4F\"\u003e\u003ciframe src=\"https:\/\/www.youtube.com\/embed\/lHPdSndKQqs?si=tktPTsRHA2Z-H07V\" title=\"Installing a Grundfos SQE Constant Pressure System\" loading=\"lazy\" frameborder=\"0\" style=\"position:absolute;top:0;left:0;width:100%;height:100%;border:0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share\" referrerpolicy=\"strict-origin-when-cross-origin\" allowfullscreen\u003e\u003c\/iframe\u003e\u003c\/div\u003e\n\u003cp style=\"font-family:Arial,Helvetica,sans-serif;font-size:13px;line-height:1.45;color:#4A4A4F;margin:8px 0 0\"\u003eInstalling a Grundfos SQE Constant Pressure System \u003cspan style=\"color:#9B9EA3\"\u003e(5:22)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cdiv style=\"position:relative;width:100%;padding-top:56.25%;background:#4A4A4F\"\u003e\u003ciframe src=\"https:\/\/www.youtube.com\/embed\/abz5iQM7O1Q?si=F0T64cB6VilEXJn0\" title=\"Grundfos CU 202 and CU 302 Control Units — Product Animation\" loading=\"lazy\" frameborder=\"0\" style=\"position:absolute;top:0;left:0;width:100%;height:100%;border:0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share\" referrerpolicy=\"strict-origin-when-cross-origin\" allowfullscreen\u003e\u003c\/iframe\u003e\u003c\/div\u003e\n\u003cp style=\"font-family:Arial,Helvetica,sans-serif;font-size:13px;line-height:1.45;color:#4A4A4F;margin:8px 0 0\"\u003eGrundfos CU 202 and CU 302 Control Units — Product Animation \u003cspan style=\"color:#9B9EA3\"\u003e(1:29 · Dutch narration)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp style=\"font-family:Arial,Helvetica,sans-serif;font-size:12px;color:#9B9EA3;margin:16px 0 0\"\u003eVideos produced by Grundfos and hosted on YouTube.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/div\u003e\u003ch5\u003eGrundfos HOME App\u003c\/h5\u003e\u003cdiv class=\"gs\"\u003e\u003cdiv class=\"gs-sec\" style=\"margin-top:6px\"\u003e\n\u003cdiv class=\"gs-h\"\u003eSet Up \u0026amp; Monitor From Your Phone\u003c\/div\u003e\n\u003cdiv class=\"gs-lead\"\u003e\u003cp\u003eThe free Grundfos HOME app gives you full control of your water system from an iOS or Android phone. It reports pump information around the clock, sends alert notifications on important events so you can act before the water goes off, and carries a built-in watering calendar with an internal clock so irrigation routines run to schedule without a timer. Installer details are stored in the app, so whoever set the system up is one tap away.\u003c\/p\u003e\u003c\/div\u003e\n\u003cdiv style=\"margin-top:16px\"\u003e\n\u003ca href=\"https:\/\/apps.apple.com\/us\/app\/grundfos-home\/id1592451846\" target=\"_blank\" rel=\"noopener\" style=\"display:inline-block;background:#B3122A;color:#fff!important;font-family:Arial Black,Arial,sans-serif;font-size:13px;letter-spacing:1px;text-transform:uppercase;text-decoration:none;padding:12px 24px;border-radius:999px;margin:0 10px 10px 0\"\u003eDownload for iOS\u003c\/a\u003e\u003ca href=\"https:\/\/play.google.com\/store\/apps\/details?id=com.grundfos.home\u0026amp;pcampaignid=web_share\" target=\"_blank\" rel=\"noopener\" style=\"display:inline-block;background:#4A4A4F;color:#fff!important;font-family:Arial Black,Arial,sans-serif;font-size:13px;letter-spacing:1px;text-transform:uppercase;text-decoration:none;padding:12px 24px;border-radius:999px;margin:0 10px 10px 0\"\u003eDownload for Android\u003c\/a\u003e\n\u003c\/div\u003e\n\u003cp style=\"font-size:12px;color:#9B9EA3;margin-top:14px;line-height:1.6\"\u003eGrundfos HOME is a free app from Grundfos Holding A\/S. It connects through the CU 302 control unit, which is required and is sold separately, and Bluetooth must be enabled on the CU 302 operating panel before pairing. Installers and service technicians use a separate free Grundfos app, Grundfos GO, as the commissioning and diagnostic tool; ask us for the link if you need it.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/div\u003e\u003c!-- \/TABS --\u003e","brand":"Grundfos","offers":[{"title":"CU 302 UL - Without Pressure Sensor - 92799799","offer_id":47457492992175,"sku":"92799799","price":772.68,"currency_code":"USD","in_stock":true},{"title":"CU 302 UL - With Pressure Sensor - 92817764","offer_id":47457493024943,"sku":"92817764","price":1020.21,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0264\/1913\/4527\/files\/Grundfos_CU302_Controller.webp?v=1788826893"},{"product_id":"grundfos-10s10-15-cue-100-well-pump-package","title":"Grundfos 10S10-15 CUE 100 Constant Pressure Well Pump Package - 1 HP, 309 ft at 10 GPM, 230V 1Ph Input - 93335193","description":"\u003c!-- TABS --\u003e\n\u003ch5\u003eDescription\u003c\/h5\u003e\n\u003cdiv class=\"gs\"\u003e\n\n\u003cdiv class=\"gs-head\"\u003e\n\u003cdiv class=\"gs-eyebrow\"\u003eGrundfos · 4 in Constant Pressure Well Pump Package\u003c\/div\u003e\n\u003cdiv class=\"gs-title\"\u003e10S10-15 CUE 100\u003c\/div\u003e\n\u003cdiv class=\"gs-sub\"\u003eConstant-pressure well water package under one Grundfos order number: a 10S10-15 stainless steel SP pump end, a 1 HP 4 in three-phase motor and a CUE 100 10 drive with its pressure transducer. Runs from 230 V single-phase service.\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"gs-badges\"\u003e\n\u003cdiv class=\"gs-badge\" style=\"background:#B3122A;color:#FFFFFF;border-color:#B3122A\"\u003e10 GPM Rated Flow\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003e309 ft at 10 GPM\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003e1 HP\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003e230V 1Ph In · 3Ph Motor\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003eConstant Pressure · Transducer Included\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003e4 in Min. Well\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003e1-1\/4 in NPT Discharge\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003eNEMA 4X Outdoor Drive\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003e58 lb Ship Weight (Package)\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eOverview\u003c\/div\u003e\n\u003cdiv class=\"gs-lead\"\u003e\n\u003cp\u003eThis package brings together the three Grundfos components of a constant-pressure well system: the 10S10-15 pump end, a 1 HP 4 in three-phase submersible motor and the CUE 100 variable-frequency drive. The drive reads the included pressure transducer and changes pump speed to hold the pressure you set as taps open and close, so the house sees steady pressure instead of a pressure switch's swing.\u003c\/p\u003e\n\u003cp\u003eThe CUE 100 takes 230 V single-phase power and makes three-phase power for the motor, so you get a three-phase pump's smooth, soft-started running on ordinary single-phase service. The drive is NEMA 4X \/ IP66 for outdoor mounting and is set up at its keypad or over Bluetooth with the free UnyConnect app.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSteady pressure.\u003c\/strong\u003e The drive holds the setpoint from one tap to full flow and slows the pump when demand drops.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStainless steel SP hydraulics.\u003c\/strong\u003e AISI 304 impellers, chambers and outer parts, a built-in check valve and a sand-handling bearing design.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDiagnostics at the wellhead.\u003c\/strong\u003e Time- and date-stamped alarms and warnings at the drive and in the app; Modbus, BACnet and Bluetooth connectivity.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"background:#FFFFFF;border:1px solid #C7CBD1;border-top:3px solid #B3122A;padding:12px 16px 12px;margin:16px 0 4px;font-size:13.5px;line-height:1.55;color:#4A4A4F\"\u003e\n\u003cdiv style=\"font-family:Arial Black,Arial,sans-serif;font-size:11px;letter-spacing:1.2px;text-transform:uppercase;color:#B3122A;margin-bottom:8px\"\u003eWhat Ships and What It Needs to Run\u003c\/div\u003e\n\u003cp style=\"margin:0 0 6px\"\u003e\u003cstrong style=\"color:#B3122A\"\u003eIncluded, under order number 93335193:\u003c\/strong\u003e the 10S10-15 SP pump end (9010015), a 1 HP 4 in three-phase MS402 motor (96465627) and the CUE 100 10 drive (93281860) with its pressure transducer. Grundfos lists them as three components of one package.\u003c\/p\u003e\n\u003cp style=\"margin:0 0 6px\"\u003e\u003cstrong style=\"color:#B3122A\"\u003eRequired, ordered separately:\u003c\/strong\u003e a diaphragm pressure tank sized to the CUE 100 instructions, drop pipe, submersible drop cable and splice kit for your setting depth, and a 230 V single-phase supply and breaker for the drive.\u003c\/p\u003e\n\u003cp style=\"margin:0 0 6px\"\u003e\u003cstrong style=\"color:#B3122A\"\u003eNever connect the motor straight to the supply.\u003c\/strong\u003e It is a three-phase motor and runs only from the CUE 100.\u003c\/p\u003e\n\u003cp style=\"margin:0\"\u003e\u003cstrong style=\"color:#B3122A\"\u003eReplacement parts:\u003c\/strong\u003e the drive alone is on our \u003ca href=\"\/products\/grundfos-cue-100-constant-pressure-drive\"\u003eGrundfos CUE 100 Constant Pressure Drive\u003c\/a\u003e listing, the motor on our \u003ca href=\"\/products\/grundfos-ms-4-in-submersible-motor\"\u003eGrundfos MS 4 in motor\u003c\/a\u003e listing and the pump end on our \u003ca href=\"\/products\/grundfos-10s-sp-4-in-submersible-pump-end\"\u003eGrundfos 10S SP pump end\u003c\/a\u003e listing.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"background:#E1E3E6;border-left:3px solid #B8BDC4;padding:8px 14px;font-size:11.5px;color:#4A4A4F;margin-top:14px;line-height:1.5\"\u003eGenuine Grundfos equipment, factory-new in original packaging — sold and supported by Watermain Supply, an independent industrial supplier.\u003c\/div\u003e\n\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eWarranty\u003c\/div\u003e\n\u003cdiv class=\"gs-lead\"\u003e\u003cp\u003e24 months from date of installation, but not more than 30 months from date of manufacture. In Grundfos's words, products are “warranted to the original user only to be free of defects in material and workmanship”; the full terms are in the installation and operating instructions on the Data Sheet tab.\u003c\/p\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eSpecifications\u003c\/div\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage order number\u003c\/td\u003e\n\u003ctd\u003e93335193\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePump end\u003c\/td\u003e\n\u003ctd\u003e10S10-15, 10 GPM rated, AISI 304 stainless steel (9010015)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor\u003c\/td\u003e\n\u003ctd\u003e1 HP, 4 in, three-phase MS402 (96465627)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrive\u003c\/td\u003e\n\u003ctd\u003eCUE 100 10, 6 A max motor service-factor current, NEMA 4X \/ IP66 outdoor (93281860)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrive supply\u003c\/td\u003e\n\u003ctd\u003e230 V, single phase in; three phase out to the motor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure transducer\u003c\/td\u003e\n\u003ctd\u003eIncluded with the drive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDischarge\u003c\/td\u003e\n\u003ctd\u003e1-1\/4 in NPT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum well\u003c\/td\u003e\n\u003ctd\u003e4 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping weight\u003c\/td\u003e\n\u003ctd\u003e58 lb, complete package\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"font-size:12.5px;color:#9B9EA3;margin-top:8px;line-height:1.55\"\u003eSource: Grundfos US groundwater price list, January 2026 (4 in CUE 100 packages and CUE 100 drives).\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eModels \u0026amp; Performance — Will It Do What You Need?\u003c\/div\u003e\n\u003cp style=\"font-size:13.5px;margin-bottom:10px\"\u003eThe first table reads like the curve: the head the pump adds from shut-off to the end of its curve. The second shows what it delivers while the drive holds 40, 50 or 60 PSI at your pumping water level.\u003c\/p\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003cth\u003eHP\u003c\/th\u003e\n\u003cth\u003e0 GPM (Shut-off)\u003c\/th\u003e\n\u003cth\u003e2.7 GPM\u003c\/th\u003e\n\u003cth\u003e6.9 GPM\u003c\/th\u003e\n\u003cth\u003e10 GPM (Rated)\u003c\/th\u003e\n\u003cth\u003e13.7 GPM (Max)\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e10S10-15\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003ctd\u003e421\u003c\/td\u003e\n\u003ctd\u003e410\u003c\/td\u003e\n\u003ctd\u003e358\u003c\/td\u003e\n\u003ctd\u003e309\u003c\/td\u003e\n\u003ctd\u003e145\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"font-size:12.5px;color:#9B9EA3;margin-top:8px;line-height:1.55\"\u003eTotal head in feet. The shut-off and flow columns are read from the Grundfos 60 Hz curve for the 10S10-15, digitized from the published vector curve in the Grundfos SP 10S data sheet (60 Hz), at the nearest published point and rounded down. The (Rated) column is the nominal head Grundfos prints for the 10S10-15 at 10 GPM, verbatim. 1 ft of head = 0.433 PSI. Full curves are in the product images and on the Data Sheet tab.\u003c\/p\u003e\n\u003cp style=\"font-size:13.5px;margin-bottom:10px;margin-top:18px\"\u003e\u003cstrong\u003eWhat It Delivers at Your Set Pressure\u003c\/strong\u003e (GPM by depth to water)\u003c\/p\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSet pressure\u003c\/th\u003e\n\u003cth\u003e20 ft\u003c\/th\u003e\n\u003cth\u003e60 ft\u003c\/th\u003e\n\u003cth\u003e120 ft\u003c\/th\u003e\n\u003cth\u003e160 ft\u003c\/th\u003e\n\u003cth\u003e200 ft\u003c\/th\u003e\n\u003cth\u003e260 ft\u003c\/th\u003e\n\u003cth\u003e300 ft\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e40 PSI\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e13.8\u003c\/td\u003e\n\u003ctd\u003e12.1\u003c\/td\u003e\n\u003ctd\u003e10.9\u003c\/td\u003e\n\u003ctd\u003e9.8\u003c\/td\u003e\n\u003ctd\u003e7.6\u003c\/td\u003e\n\u003ctd\u003e4.6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e50 PSI\u003c\/td\u003e\n\u003ctd\u003e14.1\u003c\/td\u003e\n\u003ctd\u003e13.2\u003c\/td\u003e\n\u003ctd\u003e11.4\u003c\/td\u003e\n\u003ctd\u003e10.3\u003c\/td\u003e\n\u003ctd\u003e9.1\u003c\/td\u003e\n\u003ctd\u003e6.1\u003c\/td\u003e\n\u003ctd\u003e1.7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e60 PSI\u003c\/td\u003e\n\u003ctd\u003e13.6\u003c\/td\u003e\n\u003ctd\u003e12.6\u003c\/td\u003e\n\u003ctd\u003e10.8\u003c\/td\u003e\n\u003ctd\u003e9.6\u003c\/td\u003e\n\u003ctd\u003e8.2\u003c\/td\u003e\n\u003ctd\u003e3.9\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"font-size:12.5px;color:#9B9EA3;margin-top:8px;line-height:1.55\"\u003eGPM by depth to pumping water level, verbatim from the Grundfos 10 gpm easy selection chart for the 10S10-15 (SQ, SQE, SmartFlo and SP data booklet, 60 Hz), at full speed: the most the pump delivers while the CUE 100 holds that pressure; at lower demand the drive slows the pump. Riser and pipe friction are not included. A dash means Grundfos prints no figure: on the shallow side the flow is past the chart range, on the deep side the pump cannot hold that pressure.\u003c\/p\u003e\n\u003cdiv style=\"display:flex;flex-wrap:wrap;gap:10px;margin:22px 0 4px\"\u003e\n\u003ca href=\"\/pages\/submersible-well-pump-sizing-calculator\" style=\"flex:1 1 200px;text-align:center;display:block;background:#B3122A;color:#ffffff;font-family:Arial Black,Arial,sans-serif;font-size:12px;text-transform:uppercase;letter-spacing:1.2px;padding:11px 18px;text-decoration:none\"\u003eSubmersible Calculator\u003c\/a\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eBefore You Buy — The Limits That Decide the Fit\u003c\/div\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eCheck\u003c\/th\u003e\n\u003cth\u003eWhat to confirm\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eWell size\u003c\/td\u003e\n\u003ctd\u003e4 in or larger casing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower\u003c\/td\u003e\n\u003ctd\u003e230 V single-phase supply to the drive; the motor runs only from the drive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWater\u003c\/td\u003e\n\u003ctd\u003eUp to 104°F with at least 0.25 ft\/s flowing past the 4 in motor; drinking water up to 86°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure tank\u003c\/td\u003e\n\u003ctd\u003eA diaphragm tank sized to the CUE 100 instructions, between the well and the first tap\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrive location\u003c\/td\u003e\n\u003ctd\u003eWall-mounted, indoors or outdoors (NEMA 4X); keep within the drop-cable length the CUE 100 instructions allow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSand\u003c\/td\u003e\n\u003ctd\u003eUp to 50 ppm for SP 5S-25S\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eMaterials of Construction\u003c\/div\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003ePart\u003c\/th\u003e\n\u003cth\u003eMaterial\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eImpellers, chambers, strainer, cable guard\u003c\/td\u003e\n\u003ctd\u003eAISI 304 stainless steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePump shaft\u003c\/td\u003e\n\u003ctd\u003eStainless steel, EN 1.4057\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBearings\u003c\/td\u003e\n\u003ctd\u003eNBR elastomer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor\u003c\/td\u003e\n\u003ctd\u003eWater-filled Grundfos MS submersible motor, stainless steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"font-size:12.5px;color:#9B9EA3;margin-top:8px;line-height:1.55\"\u003eSource: Grundfos SP data booklet, standard S construction.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"gs-contact\"\u003eFor engineering-led sizing and selection support or a factory submittal, email \u003ca href=\"mailto:sales@watermainsupply.com\"\u003esales@watermainsupply.com\u003c\/a\u003e or call \u003ca href=\"tel:18885104036\"\u003e1-888.510.4036\u003c\/a\u003e.\u003cbr\u003e© Watermain Supply — A division of E4 Industrial LLC\u003c\/div\u003e\n\n\u003c\/div\u003e\n\u003ch5\u003eData Sheet\u003c\/h5\u003e\u003cdiv class=\"gs\"\u003e\u003cdiv class=\"gs-dl\"\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0264\/1913\/4527\/files\/CUE_100_product_Leaflet_v3_QR.pdf?v=1788919445\" target=\"_blank\" rel=\"noopener\"\u003eCUE 100 Product Leaflet\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0264\/1913\/4527\/files\/93232651_07.2024_CUE_100_online.pdf?v=1788919445\" target=\"_blank\" rel=\"noopener\"\u003eCUE 100 Installation and Operating Instructions\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0264\/1913\/4527\/files\/LSPSL002.pdf?v=1788919444\" target=\"_blank\" rel=\"noopener\"\u003eGrundfos SP Submersible Pumps Data Booklet\u003c\/a\u003e\n\u003c\/div\u003e\u003c\/div\u003e\u003ch5\u003eVideos\u003c\/h5\u003e\u003cdiv class=\"gs\"\u003e\u003cdiv class=\"gs-sec\" style=\"margin-top:6px\"\u003e\u003cdiv style=\"display:grid;grid-template-columns:repeat(auto-fit,minmax(320px,1fr));gap:16px;max-width:900px\"\u003e\n\u003cdiv style=\"position:relative;padding-bottom:56.25%;height:0;overflow:hidden\"\u003e\u003ciframe src=\"https:\/\/www.youtube.com\/embed\/JSZLNfMMIpo\" title=\"Grundfos CUE 100 overview\" style=\"position:absolute;top:0;left:0;width:100%;height:100%;border:0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture\" allowfullscreen\u003e\u003c\/iframe\u003e\u003c\/div\u003e\n\u003cdiv style=\"position:relative;padding-bottom:56.25%;height:0;overflow:hidden\"\u003e\u003ciframe src=\"\" https: title=\"Grundfos CUE 100 setup demonstration\" style=\"position:absolute;top:0;left:0;width:100%;height:100%;border:0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture\" allowfullscreen\u003e\u003c\/iframe\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/div\u003e\u003c\/div\u003e\u003ch5\u003eUnyConnect App\u003c\/h5\u003e\u003cdiv class=\"gs\"\u003e\u003cdiv class=\"gs-sec\" style=\"margin-top:6px\"\u003e\n\u003cdiv class=\"gs-h\"\u003eSet Up At The Drive Or From Your Phone\u003c\/div\u003e\n\u003cdiv class=\"gs-lead\"\u003e\u003cp\u003eThe CUE 100 is set up at the drive keypad, or over Bluetooth with the free UnyConnect app on an iOS or Android phone. UnyConnect reads status and live operating data, sets the pressure setpoint and control parameters, and shows diagnostic alarms. Remote monitoring away from the wellhead requires the appropriate integration.\u003c\/p\u003e\u003c\/div\u003e\n\u003cdiv style=\"margin-top:16px\"\u003e\n\u003ca href=\"https:\/\/apps.apple.com\/us\/app\/unyconnect\/id6443696303\" target=\"_blank\" rel=\"noopener\" style=\"display:inline-block;background:#B3122A;color:#fff!important;font-family:Arial Black,Arial,sans-serif;font-size:13px;letter-spacing:1px;text-transform:uppercase;text-decoration:none;padding:12px 24px;border-radius:999px;margin:0 10px 10px 0\"\u003eDownload for iOS\u003c\/a\u003e\u003ca href=\"https:\/\/play.google.com\/store\/apps\/details?id=com.nastec.unyconnect\u0026amp;pcampaignid=web_share\" target=\"_blank\" rel=\"noopener\" style=\"display:inline-block;background:#4A4A4F;color:#fff!important;font-family:Arial Black,Arial,sans-serif;font-size:13px;letter-spacing:1px;text-transform:uppercase;text-decoration:none;padding:12px 24px;border-radius:999px;margin:0 10px 10px 0\"\u003eDownload for Android\u003c\/a\u003e\n\u003c\/div\u003e\n\u003cp style=\"font-size:12px;color:#9B9EA3;margin-top:12px\"\u003eUnyConnect is a free app for the CUE 100 drive. Bluetooth must be enabled on the CUE 100 before pairing.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/div\u003e\u003c!-- \/TABS --\u003e","brand":"Grundfos","offers":[{"title":"Default Title","offer_id":47465162899631,"sku":"93335193","price":3199.13,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0264\/1913\/4527\/files\/Grundfox_4_in_CUE_100_Sumbersible_pump_motor_controller_package.webp?v=1788919471"},{"product_id":"grundfos-10s15-21-cue-100-well-pump-package","title":"Grundfos 10S15-21 CUE 100 Constant Pressure Well Pump Package - 1-1\/2 HP, 433 ft at 10 GPM, 230V 1Ph Input - 93335949","description":"\u003c!-- TABS --\u003e\n\u003ch5\u003eDescription\u003c\/h5\u003e\n\u003cdiv class=\"gs\"\u003e\n\n\u003cdiv class=\"gs-head\"\u003e\n\u003cdiv class=\"gs-eyebrow\"\u003eGrundfos · 4 in Constant Pressure Well Pump Package\u003c\/div\u003e\n\u003cdiv class=\"gs-title\"\u003e10S15-21 CUE 100\u003c\/div\u003e\n\u003cdiv class=\"gs-sub\"\u003eConstant-pressure well water package under one Grundfos order number: a 10S15-21 stainless steel SP pump end, a 1-1\/2 HP 4 in three-phase motor and a CUE 100 20 drive with its pressure transducer. Runs from 230 V single-phase service.\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"gs-badges\"\u003e\n\u003cdiv class=\"gs-badge\" style=\"background:#B3122A;color:#FFFFFF;border-color:#B3122A\"\u003e10 GPM Rated Flow\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003e433 ft at 10 GPM\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003e1-1\/2 HP\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003e230V 1Ph In · 3Ph Motor\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003eConstant Pressure · Transducer Included\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003e4 in Min. Well\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003e1-1\/4 in NPT Discharge\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003eNEMA 4X Outdoor Drive\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003e64 lb Ship Weight (Package)\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eOverview\u003c\/div\u003e\n\u003cdiv class=\"gs-lead\"\u003e\n\u003cp\u003eThis package brings together the three Grundfos components of a constant-pressure well system: the 10S15-21 pump end, a 1-1\/2 HP 4 in three-phase submersible motor and the CUE 100 variable-frequency drive. The drive reads the included pressure transducer and changes pump speed to hold the pressure you set as taps open and close, so the house sees steady pressure instead of a pressure switch's swing.\u003c\/p\u003e\n\u003cp\u003eThe CUE 100 takes 230 V single-phase power and makes three-phase power for the motor, so you get a three-phase pump's smooth, soft-started running on ordinary single-phase service. The drive is NEMA 4X \/ IP66 for outdoor mounting and is set up at its keypad or over Bluetooth with the free UnyConnect app.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSteady pressure.\u003c\/strong\u003e The drive holds the setpoint from one tap to full flow and slows the pump when demand drops.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStainless steel SP hydraulics.\u003c\/strong\u003e AISI 304 impellers, chambers and outer parts, a built-in check valve and a sand-handling bearing design.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDiagnostics at the wellhead.\u003c\/strong\u003e Time- and date-stamped alarms and warnings at the drive and in the app; Modbus, BACnet and Bluetooth connectivity.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"background:#FFFFFF;border:1px solid #C7CBD1;border-top:3px solid #B3122A;padding:12px 16px 12px;margin:16px 0 4px;font-size:13.5px;line-height:1.55;color:#4A4A4F\"\u003e\n\u003cdiv style=\"font-family:Arial Black,Arial,sans-serif;font-size:11px;letter-spacing:1.2px;text-transform:uppercase;color:#B3122A;margin-bottom:8px\"\u003eWhat Ships and What It Needs to Run\u003c\/div\u003e\n\u003cp style=\"margin:0 0 6px\"\u003e\u003cstrong style=\"color:#B3122A\"\u003eIncluded, under order number 93335949:\u003c\/strong\u003e the 10S15-21 SP pump end (9010021), a 1-1\/2 HP 4 in three-phase MS402 motor (96465629) and the CUE 100 20 drive (92939786) with its pressure transducer. Grundfos lists them as three components of one package.\u003c\/p\u003e\n\u003cp style=\"margin:0 0 6px\"\u003e\u003cstrong style=\"color:#B3122A\"\u003eRequired, ordered separately:\u003c\/strong\u003e a diaphragm pressure tank sized to the CUE 100 instructions, drop pipe, submersible drop cable and splice kit for your setting depth, and a 230 V single-phase supply and breaker for the drive.\u003c\/p\u003e\n\u003cp style=\"margin:0 0 6px\"\u003e\u003cstrong style=\"color:#B3122A\"\u003eNever connect the motor straight to the supply.\u003c\/strong\u003e It is a three-phase motor and runs only from the CUE 100.\u003c\/p\u003e\n\u003cp style=\"margin:0\"\u003e\u003cstrong style=\"color:#B3122A\"\u003eReplacement parts:\u003c\/strong\u003e the drive alone is on our \u003ca href=\"\/products\/grundfos-cue-100-constant-pressure-drive\"\u003eGrundfos CUE 100 Constant Pressure Drive\u003c\/a\u003e listing, the motor on our \u003ca href=\"\/products\/grundfos-ms-4-in-submersible-motor\"\u003eGrundfos MS 4 in motor\u003c\/a\u003e listing and the pump end on our \u003ca href=\"\/products\/grundfos-10s-sp-4-in-submersible-pump-end\"\u003eGrundfos 10S SP pump end\u003c\/a\u003e listing.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"background:#E1E3E6;border-left:3px solid #B8BDC4;padding:8px 14px;font-size:11.5px;color:#4A4A4F;margin-top:14px;line-height:1.5\"\u003eGenuine Grundfos equipment, factory-new in original packaging — sold and supported by Watermain Supply, an independent industrial supplier.\u003c\/div\u003e\n\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eWarranty\u003c\/div\u003e\n\u003cdiv class=\"gs-lead\"\u003e\u003cp\u003e24 months from date of installation, but not more than 30 months from date of manufacture. In Grundfos's words, products are “warranted to the original user only to be free of defects in material and workmanship”; the full terms are in the installation and operating instructions on the Data Sheet tab.\u003c\/p\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eSpecifications\u003c\/div\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage order number\u003c\/td\u003e\n\u003ctd\u003e93335949\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePump end\u003c\/td\u003e\n\u003ctd\u003e10S15-21, 10 GPM rated, AISI 304 stainless steel (9010021)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor\u003c\/td\u003e\n\u003ctd\u003e1-1\/2 HP, 4 in, three-phase MS402 (96465629)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrive\u003c\/td\u003e\n\u003ctd\u003eCUE 100 20, 9.5 A max motor service-factor current, NEMA 4X \/ IP66 outdoor (92939786)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrive supply\u003c\/td\u003e\n\u003ctd\u003e230 V, single phase in; three phase out to the motor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure transducer\u003c\/td\u003e\n\u003ctd\u003eIncluded with the drive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDischarge\u003c\/td\u003e\n\u003ctd\u003e1-1\/4 in NPT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum well\u003c\/td\u003e\n\u003ctd\u003e4 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping weight\u003c\/td\u003e\n\u003ctd\u003e64 lb, complete package\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"font-size:12.5px;color:#9B9EA3;margin-top:8px;line-height:1.55\"\u003eSource: Grundfos US groundwater price list, January 2026 (4 in CUE 100 packages and CUE 100 drives).\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eModels \u0026amp; Performance — Will It Do What You Need?\u003c\/div\u003e\n\u003cp style=\"font-size:13.5px;margin-bottom:10px\"\u003eThe first table reads like the curve: the head the pump adds from shut-off to the end of its curve. The second shows what it delivers while the drive holds 40, 50 or 60 PSI at your pumping water level.\u003c\/p\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003cth\u003eHP\u003c\/th\u003e\n\u003cth\u003e0 GPM (Shut-off)\u003c\/th\u003e\n\u003cth\u003e2.7 GPM\u003c\/th\u003e\n\u003cth\u003e6.9 GPM\u003c\/th\u003e\n\u003cth\u003e10 GPM (Rated)\u003c\/th\u003e\n\u003cth\u003e13.7 GPM (Max)\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e10S15-21\u003c\/td\u003e\n\u003ctd\u003e1-1\/2\u003c\/td\u003e\n\u003ctd\u003e590\u003c\/td\u003e\n\u003ctd\u003e575\u003c\/td\u003e\n\u003ctd\u003e503\u003c\/td\u003e\n\u003ctd\u003e433\u003c\/td\u003e\n\u003ctd\u003e206\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"font-size:12.5px;color:#9B9EA3;margin-top:8px;line-height:1.55\"\u003eTotal head in feet. The shut-off and flow columns are read from the Grundfos 60 Hz curve for the 10S15-21, digitized from the published vector curve in the Grundfos SP 10S data sheet (60 Hz), at the nearest published point and rounded down. The (Rated) column is the nominal head Grundfos prints for the 10S15-21 at 10 GPM, verbatim. 1 ft of head = 0.433 PSI. Full curves are in the product images and on the Data Sheet tab.\u003c\/p\u003e\n\u003cp style=\"font-size:13.5px;margin-bottom:10px;margin-top:18px\"\u003e\u003cstrong\u003eWhat It Delivers at Your Set Pressure\u003c\/strong\u003e (GPM by depth to water)\u003c\/p\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSet pressure\u003c\/th\u003e\n\u003cth\u003e40 ft\u003c\/th\u003e\n\u003cth\u003e100 ft\u003c\/th\u003e\n\u003cth\u003e140 ft\u003c\/th\u003e\n\u003cth\u003e200 ft\u003c\/th\u003e\n\u003cth\u003e260 ft\u003c\/th\u003e\n\u003cth\u003e300 ft\u003c\/th\u003e\n\u003cth\u003e460 ft\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e40 PSI\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e14.1\u003c\/td\u003e\n\u003ctd\u003e13.4\u003c\/td\u003e\n\u003ctd\u003e12.2\u003c\/td\u003e\n\u003ctd\u003e10.9\u003c\/td\u003e\n\u003ctd\u003e10.1\u003c\/td\u003e\n\u003ctd\u003e4.1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e50 PSI\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e13.7\u003c\/td\u003e\n\u003ctd\u003e13\u003c\/td\u003e\n\u003ctd\u003e11.7\u003c\/td\u003e\n\u003ctd\u003e10.4\u003c\/td\u003e\n\u003ctd\u003e9.6\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e60 PSI\u003c\/td\u003e\n\u003ctd\u003e14.2\u003c\/td\u003e\n\u003ctd\u003e13.3\u003c\/td\u003e\n\u003ctd\u003e12.5\u003c\/td\u003e\n\u003ctd\u003e11.2\u003c\/td\u003e\n\u003ctd\u003e9.9\u003c\/td\u003e\n\u003ctd\u003e9.1\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"font-size:12.5px;color:#9B9EA3;margin-top:8px;line-height:1.55\"\u003eGPM by depth to pumping water level, verbatim from the Grundfos 10 gpm easy selection chart for the 10S15-21 (SQ, SQE, SmartFlo and SP data booklet, 60 Hz), at full speed: the most the pump delivers while the CUE 100 holds that pressure; at lower demand the drive slows the pump. Riser and pipe friction are not included. A dash means Grundfos prints no figure: on the shallow side the flow is past the chart range, on the deep side the pump cannot hold that pressure.\u003c\/p\u003e\n\u003cdiv style=\"display:flex;flex-wrap:wrap;gap:10px;margin:22px 0 4px\"\u003e\n\u003ca href=\"\/pages\/submersible-well-pump-sizing-calculator\" style=\"flex:1 1 200px;text-align:center;display:block;background:#B3122A;color:#ffffff;font-family:Arial Black,Arial,sans-serif;font-size:12px;text-transform:uppercase;letter-spacing:1.2px;padding:11px 18px;text-decoration:none\"\u003eSubmersible Calculator\u003c\/a\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eBefore You Buy — The Limits That Decide the Fit\u003c\/div\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eCheck\u003c\/th\u003e\n\u003cth\u003eWhat to confirm\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eWell size\u003c\/td\u003e\n\u003ctd\u003e4 in or larger casing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower\u003c\/td\u003e\n\u003ctd\u003e230 V single-phase supply to the drive; the motor runs only from the drive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWater\u003c\/td\u003e\n\u003ctd\u003eUp to 104°F with at least 0.25 ft\/s flowing past the 4 in motor; drinking water up to 86°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure tank\u003c\/td\u003e\n\u003ctd\u003eA diaphragm tank sized to the CUE 100 instructions, between the well and the first tap\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrive location\u003c\/td\u003e\n\u003ctd\u003eWall-mounted, indoors or outdoors (NEMA 4X); keep within the drop-cable length the CUE 100 instructions allow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSand\u003c\/td\u003e\n\u003ctd\u003eUp to 50 ppm for SP 5S-25S\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eMaterials of Construction\u003c\/div\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003ePart\u003c\/th\u003e\n\u003cth\u003eMaterial\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eImpellers, chambers, strainer, cable guard\u003c\/td\u003e\n\u003ctd\u003eAISI 304 stainless steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePump shaft\u003c\/td\u003e\n\u003ctd\u003eStainless steel, EN 1.4057\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBearings\u003c\/td\u003e\n\u003ctd\u003eNBR elastomer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor\u003c\/td\u003e\n\u003ctd\u003eWater-filled Grundfos MS submersible motor, stainless steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"font-size:12.5px;color:#9B9EA3;margin-top:8px;line-height:1.55\"\u003eSource: Grundfos SP data booklet, standard S construction.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"gs-contact\"\u003eFor engineering-led sizing and selection support or a factory submittal, email \u003ca href=\"mailto:sales@watermainsupply.com\"\u003esales@watermainsupply.com\u003c\/a\u003e or call \u003ca href=\"tel:18885104036\"\u003e1-888.510.4036\u003c\/a\u003e.\u003cbr\u003e© Watermain Supply — A division of E4 Industrial LLC\u003c\/div\u003e\n\n\u003c\/div\u003e\n\u003ch5\u003eData Sheet\u003c\/h5\u003e\u003cdiv class=\"gs\"\u003e\u003cdiv class=\"gs-dl\"\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0264\/1913\/4527\/files\/CUE_100_product_Leaflet_v3_QR.pdf?v=1788919445\" target=\"_blank\" rel=\"noopener\"\u003eCUE 100 Product Leaflet\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0264\/1913\/4527\/files\/93232651_07.2024_CUE_100_online.pdf?v=1788919445\" target=\"_blank\" rel=\"noopener\"\u003eCUE 100 Installation and Operating Instructions\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0264\/1913\/4527\/files\/LSPSL002.pdf?v=1788919444\" target=\"_blank\" rel=\"noopener\"\u003eGrundfos SP Submersible Pumps Data Booklet\u003c\/a\u003e\n\u003c\/div\u003e\u003c\/div\u003e\u003ch5\u003eVideos\u003c\/h5\u003e\u003cdiv class=\"gs\"\u003e\u003cdiv class=\"gs-sec\" style=\"margin-top:6px\"\u003e\u003cdiv style=\"display:grid;grid-template-columns:repeat(auto-fit,minmax(320px,1fr));gap:16px;max-width:900px\"\u003e\n\u003cdiv style=\"position:relative;padding-bottom:56.25%;height:0;overflow:hidden\"\u003e\u003ciframe src=\"https:\/\/www.youtube.com\/embed\/JSZLNfMMIpo\" title=\"Grundfos CUE 100 overview\" style=\"position:absolute;top:0;left:0;width:100%;height:100%;border:0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture\" allowfullscreen\u003e\u003c\/iframe\u003e\u003c\/div\u003e\n\u003cdiv style=\"position:relative;padding-bottom:56.25%;height:0;overflow:hidden\"\u003e\u003ciframe src=\"https:\/\/www.youtube.com\/embed\/s-6jNIZKvAI\" title=\"Grundfos CUE 100 setup demonstration\" style=\"position:absolute;top:0;left:0;width:100%;height:100%;border:0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture\" allowfullscreen\u003e\u003c\/iframe\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/div\u003e\u003c\/div\u003e\u003ch5\u003eUnyConnect App\u003c\/h5\u003e\u003cdiv class=\"gs\"\u003e\u003cdiv class=\"gs-sec\" style=\"margin-top:6px\"\u003e\n\u003cdiv class=\"gs-h\"\u003eSet Up At The Drive Or From Your Phone\u003c\/div\u003e\n\u003cdiv class=\"gs-lead\"\u003e\u003cp\u003eThe CUE 100 is set up at the drive keypad, or over Bluetooth with the free UnyConnect app on an iOS or Android phone. UnyConnect reads status and live operating data, sets the pressure setpoint and control parameters, and shows diagnostic alarms. Remote monitoring away from the wellhead requires the appropriate integration.\u003c\/p\u003e\u003c\/div\u003e\n\u003cdiv style=\"margin-top:16px\"\u003e\n\u003ca href=\"https:\/\/apps.apple.com\/us\/app\/unyconnect\/id6443696303\" target=\"_blank\" rel=\"noopener\" style=\"display:inline-block;background:#B3122A;color:#fff!important;font-family:Arial Black,Arial,sans-serif;font-size:13px;letter-spacing:1px;text-transform:uppercase;text-decoration:none;padding:12px 24px;border-radius:999px;margin:0 10px 10px 0\"\u003eDownload for iOS\u003c\/a\u003e\u003ca href=\"https:\/\/play.google.com\/store\/apps\/details?id=com.nastec.unyconnect\u0026amp;pcampaignid=web_share\" target=\"_blank\" rel=\"noopener\" style=\"display:inline-block;background:#4A4A4F;color:#fff!important;font-family:Arial Black,Arial,sans-serif;font-size:13px;letter-spacing:1px;text-transform:uppercase;text-decoration:none;padding:12px 24px;border-radius:999px;margin:0 10px 10px 0\"\u003eDownload for Android\u003c\/a\u003e\n\u003c\/div\u003e\n\u003cp style=\"font-size:12px;color:#9B9EA3;margin-top:12px\"\u003eUnyConnect is a free app for the CUE 100 drive. Bluetooth must be enabled on the CUE 100 before pairing.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/div\u003e\u003c!-- \/TABS --\u003e","brand":"Grundfos","offers":[{"title":"Default Title","offer_id":47465162932399,"sku":"93335949","price":3921.68,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0264\/1913\/4527\/files\/Grundfox_4_in_CUE_100_Sumbersible_pump_motor_controller_package.webp?v=1788919471"},{"product_id":"grundfos-10s20-27-cue-100-well-pump-package","title":"Grundfos 10S20-27 CUE 100 Constant Pressure Well Pump Package - 2 HP, 554 ft at 10 GPM, 230V 1Ph Input - 93336008","description":"\u003c!-- TABS --\u003e\n\u003ch5\u003eDescription\u003c\/h5\u003e\n\u003cdiv class=\"gs\"\u003e\n\n\u003cdiv class=\"gs-head\"\u003e\n\u003cdiv class=\"gs-eyebrow\"\u003eGrundfos · 4 in Constant Pressure Well Pump Package\u003c\/div\u003e\n\u003cdiv class=\"gs-title\"\u003e10S20-27 CUE 100\u003c\/div\u003e\n\u003cdiv class=\"gs-sub\"\u003eConstant-pressure well water package under one Grundfos order number: a 10S20-27 stainless steel SP pump end, a 2 HP 4 in three-phase motor and a CUE 100 20 drive with its pressure transducer. Runs from 230 V single-phase service.\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"gs-badges\"\u003e\n\u003cdiv class=\"gs-badge\" style=\"background:#B3122A;color:#FFFFFF;border-color:#B3122A\"\u003e10 GPM Rated Flow\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003e554 ft at 10 GPM\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003e2 HP\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003e230V 1Ph In · 3Ph Motor\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003eConstant Pressure · Transducer Included\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003e4 in Min. Well\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003e1-1\/4 in NPT Discharge\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003eNEMA 4X Outdoor Drive\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003e71 lb Ship Weight (Package)\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eOverview\u003c\/div\u003e\n\u003cdiv class=\"gs-lead\"\u003e\n\u003cp\u003eThis package brings together the three Grundfos components of a constant-pressure well system: the 10S20-27 pump end, a 2 HP 4 in three-phase submersible motor and the CUE 100 variable-frequency drive. The drive reads the included pressure transducer and changes pump speed to hold the pressure you set as taps open and close, so the house sees steady pressure instead of a pressure switch's swing.\u003c\/p\u003e\n\u003cp\u003eThe CUE 100 takes 230 V single-phase power and makes three-phase power for the motor, so you get a three-phase pump's smooth, soft-started running on ordinary single-phase service. The drive is NEMA 4X \/ IP66 for outdoor mounting and is set up at its keypad or over Bluetooth with the free UnyConnect app.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSteady pressure.\u003c\/strong\u003e The drive holds the setpoint from one tap to full flow and slows the pump when demand drops.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStainless steel SP hydraulics.\u003c\/strong\u003e AISI 304 impellers, chambers and outer parts, a built-in check valve and a sand-handling bearing design.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDiagnostics at the wellhead.\u003c\/strong\u003e Time- and date-stamped alarms and warnings at the drive and in the app; Modbus, BACnet and Bluetooth connectivity.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"background:#FFFFFF;border:1px solid #C7CBD1;border-top:3px solid #B3122A;padding:12px 16px 12px;margin:16px 0 4px;font-size:13.5px;line-height:1.55;color:#4A4A4F\"\u003e\n\u003cdiv style=\"font-family:Arial Black,Arial,sans-serif;font-size:11px;letter-spacing:1.2px;text-transform:uppercase;color:#B3122A;margin-bottom:8px\"\u003eWhat Ships and What It Needs to Run\u003c\/div\u003e\n\u003cp style=\"margin:0 0 6px\"\u003e\u003cstrong style=\"color:#B3122A\"\u003eIncluded, under order number 93336008:\u003c\/strong\u003e the 10S20-27 SP pump end (9010027), a 2 HP 4 in three-phase MS402 motor (96465630) and the CUE 100 20 drive (92939786) with its pressure transducer. Grundfos lists them as three components of one package.\u003c\/p\u003e\n\u003cp style=\"margin:0 0 6px\"\u003e\u003cstrong style=\"color:#B3122A\"\u003eRequired, ordered separately:\u003c\/strong\u003e a diaphragm pressure tank sized to the CUE 100 instructions, drop pipe, submersible drop cable and splice kit for your setting depth, and a 230 V single-phase supply and breaker for the drive.\u003c\/p\u003e\n\u003cp style=\"margin:0 0 6px\"\u003e\u003cstrong style=\"color:#B3122A\"\u003eNever connect the motor straight to the supply.\u003c\/strong\u003e It is a three-phase motor and runs only from the CUE 100.\u003c\/p\u003e\n\u003cp style=\"margin:0\"\u003e\u003cstrong style=\"color:#B3122A\"\u003eReplacement parts:\u003c\/strong\u003e the drive alone is on our \u003ca href=\"\/products\/grundfos-cue-100-constant-pressure-drive\"\u003eGrundfos CUE 100 Constant Pressure Drive\u003c\/a\u003e listing, the motor on our \u003ca href=\"\/products\/grundfos-ms-4-in-submersible-motor\"\u003eGrundfos MS 4 in motor\u003c\/a\u003e listing and the pump end on our \u003ca href=\"\/products\/grundfos-10s-sp-4-in-submersible-pump-end\"\u003eGrundfos 10S SP pump end\u003c\/a\u003e listing.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"background:#E1E3E6;border-left:3px solid #B8BDC4;padding:8px 14px;font-size:11.5px;color:#4A4A4F;margin-top:14px;line-height:1.5\"\u003eGenuine Grundfos equipment, factory-new in original packaging — sold and supported by Watermain Supply, an independent industrial supplier.\u003c\/div\u003e\n\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eWarranty\u003c\/div\u003e\n\u003cdiv class=\"gs-lead\"\u003e\u003cp\u003e24 months from date of installation, but not more than 30 months from date of manufacture. In Grundfos's words, products are “warranted to the original user only to be free of defects in material and workmanship”; the full terms are in the installation and operating instructions on the Data Sheet tab.\u003c\/p\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eSpecifications\u003c\/div\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage order number\u003c\/td\u003e\n\u003ctd\u003e93336008\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePump end\u003c\/td\u003e\n\u003ctd\u003e10S20-27, 10 GPM rated, AISI 304 stainless steel (9010027)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor\u003c\/td\u003e\n\u003ctd\u003e2 HP, 4 in, three-phase MS402 (96465630)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrive\u003c\/td\u003e\n\u003ctd\u003eCUE 100 20, 9.5 A max motor service-factor current, NEMA 4X \/ IP66 outdoor (92939786)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrive supply\u003c\/td\u003e\n\u003ctd\u003e230 V, single phase in; three phase out to the motor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure transducer\u003c\/td\u003e\n\u003ctd\u003eIncluded with the drive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDischarge\u003c\/td\u003e\n\u003ctd\u003e1-1\/4 in NPT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum well\u003c\/td\u003e\n\u003ctd\u003e4 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping weight\u003c\/td\u003e\n\u003ctd\u003e71 lb, complete package\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"font-size:12.5px;color:#9B9EA3;margin-top:8px;line-height:1.55\"\u003eSource: Grundfos US groundwater price list, January 2026 (4 in CUE 100 packages and CUE 100 drives).\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eModels \u0026amp; Performance — Will It Do What You Need?\u003c\/div\u003e\n\u003cp style=\"font-size:13.5px;margin-bottom:10px\"\u003eThe first table reads like the curve: the head the pump adds from shut-off to the end of its curve. The second shows what it delivers while the drive holds 40, 50 or 60 PSI at your pumping water level.\u003c\/p\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003cth\u003eHP\u003c\/th\u003e\n\u003cth\u003e0 GPM (Shut-off)\u003c\/th\u003e\n\u003cth\u003e2.7 GPM\u003c\/th\u003e\n\u003cth\u003e6.9 GPM\u003c\/th\u003e\n\u003cth\u003e10 GPM (Rated)\u003c\/th\u003e\n\u003cth\u003e13.7 GPM (Max)\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e10S20-27\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e756\u003c\/td\u003e\n\u003ctd\u003e734\u003c\/td\u003e\n\u003ctd\u003e640\u003c\/td\u003e\n\u003ctd\u003e554\u003c\/td\u003e\n\u003ctd\u003e255\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"font-size:12.5px;color:#9B9EA3;margin-top:8px;line-height:1.55\"\u003eTotal head in feet. The shut-off and flow columns are read from the Grundfos 60 Hz curve for the 10S20-27, digitized from the published vector curve in the Grundfos SP 10S data sheet (60 Hz), at the nearest published point and rounded down. The (Rated) column is the nominal head Grundfos prints for the 10S20-27 at 10 GPM, verbatim. 1 ft of head = 0.433 PSI. Full curves are in the product images and on the Data Sheet tab.\u003c\/p\u003e\n\u003cp style=\"font-size:13.5px;margin-bottom:10px;margin-top:18px\"\u003e\u003cstrong\u003eWhat It Delivers at Your Set Pressure\u003c\/strong\u003e (GPM by depth to water)\u003c\/p\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSet pressure\u003c\/th\u003e\n\u003cth\u003e100 ft\u003c\/th\u003e\n\u003cth\u003e140 ft\u003c\/th\u003e\n\u003cth\u003e200 ft\u003c\/th\u003e\n\u003cth\u003e260 ft\u003c\/th\u003e\n\u003cth\u003e300 ft\u003c\/th\u003e\n\u003cth\u003e400 ft\u003c\/th\u003e\n\u003cth\u003e600 ft\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e40 PSI\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e14.2\u003c\/td\u003e\n\u003ctd\u003e13.5\u003c\/td\u003e\n\u003ctd\u003e12.6\u003c\/td\u003e\n\u003ctd\u003e11.9\u003c\/td\u003e\n\u003ctd\u003e10.3\u003c\/td\u003e\n\u003ctd\u003e5.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e50 PSI\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e14\u003c\/td\u003e\n\u003ctd\u003e13.2\u003c\/td\u003e\n\u003ctd\u003e12.2\u003c\/td\u003e\n\u003ctd\u003e11.5\u003c\/td\u003e\n\u003ctd\u003e9.9\u003c\/td\u003e\n\u003ctd\u003e3.8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e60 PSI\u003c\/td\u003e\n\u003ctd\u003e14.1\u003c\/td\u003e\n\u003ctd\u003e13.7\u003c\/td\u003e\n\u003ctd\u003e12.8\u003c\/td\u003e\n\u003ctd\u003e11.8\u003c\/td\u003e\n\u003ctd\u003e11.1\u003c\/td\u003e\n\u003ctd\u003e9.5\u003c\/td\u003e\n\u003ctd\u003e2.1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"font-size:12.5px;color:#9B9EA3;margin-top:8px;line-height:1.55\"\u003eGPM by depth to pumping water level, verbatim from the Grundfos 10 gpm easy selection chart for the 10S20-27 (SQ, SQE, SmartFlo and SP data booklet, 60 Hz), at full speed: the most the pump delivers while the CUE 100 holds that pressure; at lower demand the drive slows the pump. Riser and pipe friction are not included. A dash means Grundfos prints no figure: on the shallow side the flow is past the chart range, on the deep side the pump cannot hold that pressure.\u003c\/p\u003e\n\u003cdiv style=\"display:flex;flex-wrap:wrap;gap:10px;margin:22px 0 4px\"\u003e\n\u003ca href=\"\/pages\/submersible-well-pump-sizing-calculator\" style=\"flex:1 1 200px;text-align:center;display:block;background:#B3122A;color:#ffffff;font-family:Arial Black,Arial,sans-serif;font-size:12px;text-transform:uppercase;letter-spacing:1.2px;padding:11px 18px;text-decoration:none\"\u003eSubmersible Calculator\u003c\/a\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eBefore You Buy — The Limits That Decide the Fit\u003c\/div\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eCheck\u003c\/th\u003e\n\u003cth\u003eWhat to confirm\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eWell size\u003c\/td\u003e\n\u003ctd\u003e4 in or larger casing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower\u003c\/td\u003e\n\u003ctd\u003e230 V single-phase supply to the drive; the motor runs only from the drive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWater\u003c\/td\u003e\n\u003ctd\u003eUp to 104°F with at least 0.25 ft\/s flowing past the 4 in motor; drinking water up to 86°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure tank\u003c\/td\u003e\n\u003ctd\u003eA diaphragm tank sized to the CUE 100 instructions, between the well and the first tap\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrive location\u003c\/td\u003e\n\u003ctd\u003eWall-mounted, indoors or outdoors (NEMA 4X); keep within the drop-cable length the CUE 100 instructions allow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSand\u003c\/td\u003e\n\u003ctd\u003eUp to 50 ppm for SP 5S-25S\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eMaterials of Construction\u003c\/div\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003ePart\u003c\/th\u003e\n\u003cth\u003eMaterial\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eImpellers, chambers, strainer, cable guard\u003c\/td\u003e\n\u003ctd\u003eAISI 304 stainless steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePump shaft\u003c\/td\u003e\n\u003ctd\u003eStainless steel, EN 1.4057\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBearings\u003c\/td\u003e\n\u003ctd\u003eNBR elastomer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor\u003c\/td\u003e\n\u003ctd\u003eWater-filled Grundfos MS submersible motor, stainless steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"font-size:12.5px;color:#9B9EA3;margin-top:8px;line-height:1.55\"\u003eSource: Grundfos SP data booklet, standard S construction.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"gs-contact\"\u003eFor engineering-led sizing and selection support or a factory submittal, email \u003ca href=\"mailto:sales@watermainsupply.com\"\u003esales@watermainsupply.com\u003c\/a\u003e or call \u003ca href=\"tel:18885104036\"\u003e1-888.510.4036\u003c\/a\u003e.\u003cbr\u003e© Watermain Supply — A division of E4 Industrial LLC\u003c\/div\u003e\n\n\u003c\/div\u003e\n\u003ch5\u003eData Sheet\u003c\/h5\u003e\u003cdiv class=\"gs\"\u003e\u003cdiv class=\"gs-dl\"\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0264\/1913\/4527\/files\/CUE_100_product_Leaflet_v3_QR.pdf?v=1788919445\" target=\"_blank\" rel=\"noopener\"\u003eCUE 100 Product Leaflet\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0264\/1913\/4527\/files\/93232651_07.2024_CUE_100_online.pdf?v=1788919445\" target=\"_blank\" rel=\"noopener\"\u003eCUE 100 Installation and Operating Instructions\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0264\/1913\/4527\/files\/LSPSL002.pdf?v=1788919444\" target=\"_blank\" rel=\"noopener\"\u003eGrundfos SP Submersible Pumps Data Booklet\u003c\/a\u003e\n\u003c\/div\u003e\u003c\/div\u003e\u003ch5\u003eVideos\u003c\/h5\u003e\u003cdiv class=\"gs\"\u003e\u003cdiv class=\"gs-sec\" style=\"margin-top:6px\"\u003e\u003cdiv style=\"display:grid;grid-template-columns:repeat(auto-fit,minmax(320px,1fr));gap:16px;max-width:900px\"\u003e\n\u003cdiv style=\"position:relative;padding-bottom:56.25%;height:0;overflow:hidden\"\u003e\u003ciframe src=\"https:\/\/www.youtube.com\/embed\/JSZLNfMMIpo\" title=\"Grundfos CUE 100 overview\" style=\"position:absolute;top:0;left:0;width:100%;height:100%;border:0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture\" allowfullscreen\u003e\u003c\/iframe\u003e\u003c\/div\u003e\n\u003cdiv style=\"position:relative;padding-bottom:56.25%;height:0;overflow:hidden\"\u003e\u003ciframe src=\"https:\/\/www.youtube.com\/embed\/s-6jNIZKvAI\" title=\"Grundfos CUE 100 setup demonstration\" style=\"position:absolute;top:0;left:0;width:100%;height:100%;border:0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture\" allowfullscreen\u003e\u003c\/iframe\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/div\u003e\u003c\/div\u003e\u003ch5\u003eUnyConnect App\u003c\/h5\u003e\u003cdiv class=\"gs\"\u003e\u003cdiv class=\"gs-sec\" style=\"margin-top:6px\"\u003e\n\u003cdiv class=\"gs-h\"\u003eSet Up At The Drive Or From Your Phone\u003c\/div\u003e\n\u003cdiv class=\"gs-lead\"\u003e\u003cp\u003eThe CUE 100 is set up at the drive keypad, or over Bluetooth with the free UnyConnect app on an iOS or Android phone. UnyConnect reads status and live operating data, sets the pressure setpoint and control parameters, and shows diagnostic alarms. Remote monitoring away from the wellhead requires the appropriate integration.\u003c\/p\u003e\u003c\/div\u003e\n\u003cdiv style=\"margin-top:16px\"\u003e\n\u003ca href=\"https:\/\/apps.apple.com\/us\/app\/unyconnect\/id6443696303\" target=\"_blank\" rel=\"noopener\" style=\"display:inline-block;background:#B3122A;color:#fff!important;font-family:Arial Black,Arial,sans-serif;font-size:13px;letter-spacing:1px;text-transform:uppercase;text-decoration:none;padding:12px 24px;border-radius:999px;margin:0 10px 10px 0\"\u003eDownload for iOS\u003c\/a\u003e\u003ca href=\"https:\/\/play.google.com\/store\/apps\/details?id=com.nastec.unyconnect\u0026amp;pcampaignid=web_share\" target=\"_blank\" rel=\"noopener\" style=\"display:inline-block;background:#4A4A4F;color:#fff!important;font-family:Arial Black,Arial,sans-serif;font-size:13px;letter-spacing:1px;text-transform:uppercase;text-decoration:none;padding:12px 24px;border-radius:999px;margin:0 10px 10px 0\"\u003eDownload for Android\u003c\/a\u003e\n\u003c\/div\u003e\n\u003cp style=\"font-size:12px;color:#9B9EA3;margin-top:12px\"\u003eUnyConnect is a free app for the CUE 100 drive. Bluetooth must be enabled on the CUE 100 before pairing.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/div\u003e\u003c!-- \/TABS --\u003e","brand":"Grundfos","offers":[{"title":"Default Title","offer_id":47465162965167,"sku":"93336008","price":4077.09,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0264\/1913\/4527\/files\/Grundfox_4_in_CUE_100_Sumbersible_pump_motor_controller_package.webp?v=1788919471"},{"product_id":"grundfos-10s30-34-cue-100-well-pump-package","title":"Grundfos 10S30-34 CUE 100 Constant Pressure Well Pump Package - 3 HP, 716 ft at 10 GPM, 208-230V 1Ph Input - 93336024","description":"\u003c!-- TABS --\u003e\n\u003ch5\u003eDescription\u003c\/h5\u003e\n\u003cdiv class=\"gs\"\u003e\n\n\u003cdiv class=\"gs-head\"\u003e\n\u003cdiv class=\"gs-eyebrow\"\u003eGrundfos · 4 in Constant Pressure Well Pump Package\u003c\/div\u003e\n\u003cdiv class=\"gs-title\"\u003e10S30-34 CUE 100\u003c\/div\u003e\n\u003cdiv class=\"gs-sub\"\u003eConstant-pressure well water package under one Grundfos order number: a 10S30-34 stainless steel SP pump end, a 3 HP 4 in three-phase motor and a CUE 100 30 drive with its pressure transducer. Runs from 208-230 V single-phase service.\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"gs-badges\"\u003e\n\u003cdiv class=\"gs-badge\" style=\"background:#B3122A;color:#FFFFFF;border-color:#B3122A\"\u003e10 GPM Rated Flow\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003e716 ft at 10 GPM\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003e3 HP\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003e208-230V 1Ph In · 3Ph Motor\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003eConstant Pressure · Transducer Included\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003e4 in Min. Well\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003e1-1\/4 in NPT Discharge\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003eNEMA 4X Outdoor Drive\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003e99 lb Ship Weight (Package)\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eOverview\u003c\/div\u003e\n\u003cdiv class=\"gs-lead\"\u003e\n\u003cp\u003eThis package brings together the three Grundfos components of a constant-pressure well system: the 10S30-34 pump end, a 3 HP 4 in three-phase submersible motor and the CUE 100 variable-frequency drive. The drive reads the included pressure transducer and changes pump speed to hold the pressure you set as taps open and close, so the house sees steady pressure instead of a pressure switch's swing.\u003c\/p\u003e\n\u003cp\u003eThe CUE 100 takes 208-230 V single-phase power and makes three-phase power for the motor, so you get a three-phase pump's smooth, soft-started running on ordinary single-phase service. The drive is NEMA 4X \/ IP66 for outdoor mounting and is set up at its keypad or over Bluetooth with the free UnyConnect app.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSteady pressure.\u003c\/strong\u003e The drive holds the setpoint from one tap to full flow and slows the pump when demand drops.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStainless steel SP hydraulics.\u003c\/strong\u003e AISI 304 impellers, chambers and outer parts, a built-in check valve and a sand-handling bearing design.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDiagnostics at the wellhead.\u003c\/strong\u003e Time- and date-stamped alarms and warnings at the drive and in the app; Modbus, BACnet and Bluetooth connectivity.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"background:#FFFFFF;border:1px solid #C7CBD1;border-top:3px solid #B3122A;padding:12px 16px 12px;margin:16px 0 4px;font-size:13.5px;line-height:1.55;color:#4A4A4F\"\u003e\n\u003cdiv style=\"font-family:Arial Black,Arial,sans-serif;font-size:11px;letter-spacing:1.2px;text-transform:uppercase;color:#B3122A;margin-bottom:8px\"\u003eWhat Ships and What It Needs to Run\u003c\/div\u003e\n\u003cp style=\"margin:0 0 6px\"\u003e\u003cstrong style=\"color:#B3122A\"\u003eIncluded, under order number 93336024:\u003c\/strong\u003e the 10S30-34 SP pump end (9110034), a 3 HP 4 in three-phase MS4000 motor (92959950) and the CUE 100 30 drive (92939800) with its pressure transducer. Grundfos lists them as three components of one package.\u003c\/p\u003e\n\u003cp style=\"margin:0 0 6px\"\u003e\u003cstrong style=\"color:#B3122A\"\u003eRequired, ordered separately:\u003c\/strong\u003e a diaphragm pressure tank sized to the CUE 100 instructions, drop pipe, submersible drop cable and splice kit for your setting depth, and a 208-230 V single-phase supply and breaker for the drive.\u003c\/p\u003e\n\u003cp style=\"margin:0 0 6px\"\u003e\u003cstrong style=\"color:#B3122A\"\u003eNever connect the motor straight to the supply.\u003c\/strong\u003e It is a three-phase motor and runs only from the CUE 100.\u003c\/p\u003e\n\u003cp style=\"margin:0\"\u003e\u003cstrong style=\"color:#B3122A\"\u003eReplacement parts:\u003c\/strong\u003e the drive alone is on our \u003ca href=\"\/products\/grundfos-cue-100-constant-pressure-drive\"\u003eGrundfos CUE 100 Constant Pressure Drive\u003c\/a\u003e listing, the motor on our \u003ca href=\"\/products\/grundfos-ms-4-in-submersible-motor\"\u003eGrundfos MS 4 in motor\u003c\/a\u003e listing and the pump end on our \u003ca href=\"\/products\/grundfos-10s-sp-4-in-submersible-pump-end\"\u003eGrundfos 10S SP pump end\u003c\/a\u003e listing.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"background:#E1E3E6;border-left:3px solid #B8BDC4;padding:8px 14px;font-size:11.5px;color:#4A4A4F;margin-top:14px;line-height:1.5\"\u003eGenuine Grundfos equipment, factory-new in original packaging — sold and supported by Watermain Supply, an independent industrial supplier.\u003c\/div\u003e\n\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eWarranty\u003c\/div\u003e\n\u003cdiv class=\"gs-lead\"\u003e\u003cp\u003e24 months from date of installation, but not more than 30 months from date of manufacture. In Grundfos's words, products are “warranted to the original user only to be free of defects in material and workmanship”; the full terms are in the installation and operating instructions on the Data Sheet tab.\u003c\/p\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eSpecifications\u003c\/div\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage order number\u003c\/td\u003e\n\u003ctd\u003e93336024\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePump end\u003c\/td\u003e\n\u003ctd\u003e10S30-34, 10 GPM rated, AISI 304 stainless steel (9110034)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor\u003c\/td\u003e\n\u003ctd\u003e3 HP, 4 in, three-phase MS4000 (92959950)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrive\u003c\/td\u003e\n\u003ctd\u003eCUE 100 30, 12.5 A max motor service-factor current, NEMA 4X \/ IP66 outdoor (92939800)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrive supply\u003c\/td\u003e\n\u003ctd\u003e208-230 V, single phase in; three phase out to the motor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure transducer\u003c\/td\u003e\n\u003ctd\u003eIncluded with the drive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDischarge\u003c\/td\u003e\n\u003ctd\u003e1-1\/4 in NPT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum well\u003c\/td\u003e\n\u003ctd\u003e4 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping weight\u003c\/td\u003e\n\u003ctd\u003e99 lb, complete package\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"font-size:12.5px;color:#9B9EA3;margin-top:8px;line-height:1.55\"\u003eSource: Grundfos US groundwater price list, January 2026 (4 in CUE 100 packages and CUE 100 drives).\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eModels \u0026amp; Performance — Will It Do What You Need?\u003c\/div\u003e\n\u003cp style=\"font-size:13.5px;margin-bottom:10px\"\u003eThe first table reads like the curve: the head the pump adds from shut-off to the end of its curve. The second shows what it delivers while the drive holds 40, 50 or 60 PSI at your pumping water level.\u003c\/p\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003cth\u003eHP\u003c\/th\u003e\n\u003cth\u003e0 GPM (Shut-off)\u003c\/th\u003e\n\u003cth\u003e2.7 GPM\u003c\/th\u003e\n\u003cth\u003e6.9 GPM\u003c\/th\u003e\n\u003cth\u003e10 GPM (Rated)\u003c\/th\u003e\n\u003cth\u003e13.7 GPM (Max)\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e10S30-34\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003ctd\u003e979\u003c\/td\u003e\n\u003ctd\u003e941\u003c\/td\u003e\n\u003ctd\u003e821\u003c\/td\u003e\n\u003ctd\u003e716\u003c\/td\u003e\n\u003ctd\u003e313\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"font-size:12.5px;color:#9B9EA3;margin-top:8px;line-height:1.55\"\u003eTotal head in feet. The shut-off and flow columns are read from the Grundfos 60 Hz curve for the 10S30-34, digitized from the published vector curve in the Grundfos SP 10S data sheet (60 Hz), at the nearest published point and rounded down. The (Rated) column is the nominal head Grundfos prints for the 10S30-34 at 10 GPM, verbatim. 1 ft of head = 0.433 PSI. Full curves are in the product images and on the Data Sheet tab.\u003c\/p\u003e\n\u003cp style=\"font-size:13.5px;margin-bottom:10px;margin-top:18px\"\u003e\u003cstrong\u003eWhat It Delivers at Your Set Pressure\u003c\/strong\u003e (GPM by depth to water)\u003c\/p\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSet pressure\u003c\/th\u003e\n\u003cth\u003e200 ft\u003c\/th\u003e\n\u003cth\u003e240 ft\u003c\/th\u003e\n\u003cth\u003e280 ft\u003c\/th\u003e\n\u003cth\u003e340 ft\u003c\/th\u003e\n\u003cth\u003e460 ft\u003c\/th\u003e\n\u003cth\u003e600 ft\u003c\/th\u003e\n\u003cth\u003e800 ft\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e40 PSI\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e13.8\u003c\/td\u003e\n\u003ctd\u003e13.5\u003c\/td\u003e\n\u003ctd\u003e12.8\u003c\/td\u003e\n\u003ctd\u003e11.5\u003c\/td\u003e\n\u003ctd\u003e9.7\u003c\/td\u003e\n\u003ctd\u003e5.1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e50 PSI\u003c\/td\u003e\n\u003ctd\u003e14\u003c\/td\u003e\n\u003ctd\u003e13.6\u003c\/td\u003e\n\u003ctd\u003e13.2\u003c\/td\u003e\n\u003ctd\u003e12.6\u003c\/td\u003e\n\u003ctd\u003e11.2\u003c\/td\u003e\n\u003ctd\u003e9.4\u003c\/td\u003e\n\u003ctd\u003e4.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e60 PSI\u003c\/td\u003e\n\u003ctd\u003e13.8\u003c\/td\u003e\n\u003ctd\u003e13.4\u003c\/td\u003e\n\u003ctd\u003e13\u003c\/td\u003e\n\u003ctd\u003e12.3\u003c\/td\u003e\n\u003ctd\u003e10.9\u003c\/td\u003e\n\u003ctd\u003e9\u003c\/td\u003e\n\u003ctd\u003e3.1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"font-size:12.5px;color:#9B9EA3;margin-top:8px;line-height:1.55\"\u003eGPM by depth to pumping water level, verbatim from the Grundfos 10 gpm easy selection chart for the 10S30-34 (SQ, SQE, SmartFlo and SP data booklet, 60 Hz), at full speed: the most the pump delivers while the CUE 100 holds that pressure; at lower demand the drive slows the pump. Riser and pipe friction are not included. A dash means Grundfos prints no figure: on the shallow side the flow is past the chart range, on the deep side the pump cannot hold that pressure.\u003c\/p\u003e\n\u003cdiv style=\"display:flex;flex-wrap:wrap;gap:10px;margin:22px 0 4px\"\u003e\n\u003ca href=\"\/pages\/submersible-well-pump-sizing-calculator\" style=\"flex:1 1 200px;text-align:center;display:block;background:#B3122A;color:#ffffff;font-family:Arial Black,Arial,sans-serif;font-size:12px;text-transform:uppercase;letter-spacing:1.2px;padding:11px 18px;text-decoration:none\"\u003eSubmersible Calculator\u003c\/a\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eBefore You Buy — The Limits That Decide the Fit\u003c\/div\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eCheck\u003c\/th\u003e\n\u003cth\u003eWhat to confirm\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eWell size\u003c\/td\u003e\n\u003ctd\u003e4 in or larger casing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower\u003c\/td\u003e\n\u003ctd\u003e208-230 V single-phase supply to the drive; the motor runs only from the drive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWater\u003c\/td\u003e\n\u003ctd\u003eUp to 104°F with at least 0.25 ft\/s flowing past the 4 in motor; drinking water up to 86°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure tank\u003c\/td\u003e\n\u003ctd\u003eA diaphragm tank sized to the CUE 100 instructions, between the well and the first tap\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrive location\u003c\/td\u003e\n\u003ctd\u003eWall-mounted, indoors or outdoors (NEMA 4X); keep within the drop-cable length the CUE 100 instructions allow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSand\u003c\/td\u003e\n\u003ctd\u003eUp to 50 ppm for SP 5S-25S\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eMaterials of Construction\u003c\/div\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003ePart\u003c\/th\u003e\n\u003cth\u003eMaterial\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eImpellers, chambers, strainer, cable guard\u003c\/td\u003e\n\u003ctd\u003eAISI 304 stainless steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePump shaft\u003c\/td\u003e\n\u003ctd\u003eStainless steel, EN 1.4057\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBearings\u003c\/td\u003e\n\u003ctd\u003eNBR elastomer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor\u003c\/td\u003e\n\u003ctd\u003eWater-filled Grundfos MS submersible motor, stainless steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"font-size:12.5px;color:#9B9EA3;margin-top:8px;line-height:1.55\"\u003eSource: Grundfos SP data booklet, standard S construction.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"gs-contact\"\u003eFor engineering-led sizing and selection support or a factory submittal, email \u003ca href=\"mailto:sales@watermainsupply.com\"\u003esales@watermainsupply.com\u003c\/a\u003e or call \u003ca href=\"tel:18885104036\"\u003e1-888.510.4036\u003c\/a\u003e.\u003cbr\u003e© Watermain Supply — A division of E4 Industrial LLC\u003c\/div\u003e\n\n\u003c\/div\u003e\n\u003ch5\u003eData Sheet\u003c\/h5\u003e\u003cdiv class=\"gs\"\u003e\u003cdiv class=\"gs-dl\"\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0264\/1913\/4527\/files\/CUE_100_product_Leaflet_v3_QR.pdf?v=1788919445\" target=\"_blank\" rel=\"noopener\"\u003eCUE 100 Product Leaflet\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0264\/1913\/4527\/files\/93232651_07.2024_CUE_100_online.pdf?v=1788919445\" target=\"_blank\" rel=\"noopener\"\u003eCUE 100 Installation and Operating Instructions\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0264\/1913\/4527\/files\/LSPSL002.pdf?v=1788919444\" target=\"_blank\" rel=\"noopener\"\u003eGrundfos SP Submersible Pumps Data Booklet\u003c\/a\u003e\n\u003c\/div\u003e\u003c\/div\u003e\u003ch5\u003eVideos\u003c\/h5\u003e\u003cdiv class=\"gs\"\u003e\u003cdiv class=\"gs-sec\" style=\"margin-top:6px\"\u003e\u003cdiv style=\"display:grid;grid-template-columns:repeat(auto-fit,minmax(320px,1fr));gap:16px;max-width:900px\"\u003e\n\u003cdiv style=\"position:relative;padding-bottom:56.25%;height:0;overflow:hidden\"\u003e\u003ciframe src=\"https:\/\/www.youtube.com\/embed\/JSZLNfMMIpo\" title=\"Grundfos CUE 100 overview\" style=\"position:absolute;top:0;left:0;width:100%;height:100%;border:0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture\" allowfullscreen\u003e\u003c\/iframe\u003e\u003c\/div\u003e\n\u003cdiv style=\"position:relative;padding-bottom:56.25%;height:0;overflow:hidden\"\u003e\u003ciframe src=\"https:\/\/www.youtube.com\/embed\/s-6jNIZKvAI\" title=\"Grundfos CUE 100 setup demonstration\" style=\"position:absolute;top:0;left:0;width:100%;height:100%;border:0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture\" allowfullscreen\u003e\u003c\/iframe\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/div\u003e\u003c\/div\u003e\u003ch5\u003eUnyConnect App\u003c\/h5\u003e\u003cdiv class=\"gs\"\u003e\u003cdiv class=\"gs-sec\" style=\"margin-top:6px\"\u003e\n\u003cdiv class=\"gs-h\"\u003eSet Up At The Drive Or From Your Phone\u003c\/div\u003e\n\u003cdiv class=\"gs-lead\"\u003e\u003cp\u003eThe CUE 100 is set up at the drive keypad, or over Bluetooth with the free UnyConnect app on an iOS or Android phone. UnyConnect reads status and live operating data, sets the pressure setpoint and control parameters, and shows diagnostic alarms. Remote monitoring away from the wellhead requires the appropriate integration.\u003c\/p\u003e\u003c\/div\u003e\n\u003cdiv style=\"margin-top:16px\"\u003e\n\u003ca href=\"https:\/\/apps.apple.com\/us\/app\/unyconnect\/id6443696303\" target=\"_blank\" rel=\"noopener\" style=\"display:inline-block;background:#B3122A;color:#fff!important;font-family:Arial Black,Arial,sans-serif;font-size:13px;letter-spacing:1px;text-transform:uppercase;text-decoration:none;padding:12px 24px;border-radius:999px;margin:0 10px 10px 0\"\u003eDownload for iOS\u003c\/a\u003e\u003ca href=\"https:\/\/play.google.com\/store\/apps\/details?id=com.nastec.unyconnect\u0026amp;pcampaignid=web_share\" target=\"_blank\" rel=\"noopener\" style=\"display:inline-block;background:#4A4A4F;color:#fff!important;font-family:Arial Black,Arial,sans-serif;font-size:13px;letter-spacing:1px;text-transform:uppercase;text-decoration:none;padding:12px 24px;border-radius:999px;margin:0 10px 10px 0\"\u003eDownload for Android\u003c\/a\u003e\n\u003c\/div\u003e\n\u003cp style=\"font-size:12px;color:#9B9EA3;margin-top:12px\"\u003eUnyConnect is a free app for the CUE 100 drive. Bluetooth must be enabled on the CUE 100 before pairing.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/div\u003e\u003c!-- \/TABS --\u003e","brand":"Grundfos","offers":[{"title":"Default Title","offer_id":47465162997935,"sku":"93336024","price":6034.8,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0264\/1913\/4527\/files\/Grundfox_4_in_CUE_100_Sumbersible_pump_motor_controller_package.webp?v=1788919471"},{"product_id":"grundfos-16s10-10-cue-100-well-pump-package","title":"Grundfos 16S10-10 CUE 100 Constant Pressure Well Pump Package - 1 HP, 223 ft at 16 GPM, 230V 1Ph Input - 93336025","description":"\u003c!-- TABS --\u003e\n\u003ch5\u003eDescription\u003c\/h5\u003e\n\u003cdiv class=\"gs\"\u003e\n\n\u003cdiv class=\"gs-head\"\u003e\n\u003cdiv class=\"gs-eyebrow\"\u003eGrundfos · 4 in Constant Pressure Well Pump Package\u003c\/div\u003e\n\u003cdiv class=\"gs-title\"\u003e16S10-10 CUE 100\u003c\/div\u003e\n\u003cdiv class=\"gs-sub\"\u003eConstant-pressure well water package under one Grundfos order number: a 16S10-10 stainless steel SP pump end, a 1 HP 4 in three-phase motor and a CUE 100 10 drive with its pressure transducer. Runs from 230 V single-phase service.\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"gs-badges\"\u003e\n\u003cdiv class=\"gs-badge\" style=\"background:#B3122A;color:#FFFFFF;border-color:#B3122A\"\u003e16 GPM Rated Flow\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003e223 ft at 16 GPM\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003e1 HP\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003e230V 1Ph In · 3Ph Motor\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003eConstant Pressure · Transducer Included\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003e4 in Min. Well\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003e1-1\/4 in NPT Discharge\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003eNEMA 4X Outdoor Drive\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003e57 lb Ship Weight (Package)\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eOverview\u003c\/div\u003e\n\u003cdiv class=\"gs-lead\"\u003e\n\u003cp\u003eThis package brings together the three Grundfos components of a constant-pressure well system: the 16S10-10 pump end, a 1 HP 4 in three-phase submersible motor and the CUE 100 variable-frequency drive. The drive reads the included pressure transducer and changes pump speed to hold the pressure you set as taps open and close, so the house sees steady pressure instead of a pressure switch's swing.\u003c\/p\u003e\n\u003cp\u003eThe CUE 100 takes 230 V single-phase power and makes three-phase power for the motor, so you get a three-phase pump's smooth, soft-started running on ordinary single-phase service. The drive is NEMA 4X \/ IP66 for outdoor mounting and is set up at its keypad or over Bluetooth with the free UnyConnect app.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSteady pressure.\u003c\/strong\u003e The drive holds the setpoint from one tap to full flow and slows the pump when demand drops.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStainless steel SP hydraulics.\u003c\/strong\u003e AISI 304 impellers, chambers and outer parts, a built-in check valve and a sand-handling bearing design.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDiagnostics at the wellhead.\u003c\/strong\u003e Time- and date-stamped alarms and warnings at the drive and in the app; Modbus, BACnet and Bluetooth connectivity.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"background:#FFFFFF;border:1px solid #C7CBD1;border-top:3px solid #B3122A;padding:12px 16px 12px;margin:16px 0 4px;font-size:13.5px;line-height:1.55;color:#4A4A4F\"\u003e\n\u003cdiv style=\"font-family:Arial Black,Arial,sans-serif;font-size:11px;letter-spacing:1.2px;text-transform:uppercase;color:#B3122A;margin-bottom:8px\"\u003eWhat Ships and What It Needs to Run\u003c\/div\u003e\n\u003cp style=\"margin:0 0 6px\"\u003e\u003cstrong style=\"color:#B3122A\"\u003eIncluded, under order number 93336025:\u003c\/strong\u003e the 16S10-10 SP pump end (10010010), a 1 HP 4 in three-phase MS402 motor (96465627) and the CUE 100 10 drive (93281860) with its pressure transducer. Grundfos lists them as three components of one package.\u003c\/p\u003e\n\u003cp style=\"margin:0 0 6px\"\u003e\u003cstrong style=\"color:#B3122A\"\u003eRequired, ordered separately:\u003c\/strong\u003e a diaphragm pressure tank sized to the CUE 100 instructions, drop pipe, submersible drop cable and splice kit for your setting depth, and a 230 V single-phase supply and breaker for the drive.\u003c\/p\u003e\n\u003cp style=\"margin:0 0 6px\"\u003e\u003cstrong style=\"color:#B3122A\"\u003eNever connect the motor straight to the supply.\u003c\/strong\u003e It is a three-phase motor and runs only from the CUE 100.\u003c\/p\u003e\n\u003cp style=\"margin:0\"\u003e\u003cstrong style=\"color:#B3122A\"\u003eReplacement parts:\u003c\/strong\u003e the drive alone is on our \u003ca href=\"\/products\/grundfos-cue-100-constant-pressure-drive\"\u003eGrundfos CUE 100 Constant Pressure Drive\u003c\/a\u003e listing, the motor on our \u003ca href=\"\/products\/grundfos-ms-4-in-submersible-motor\"\u003eGrundfos MS 4 in motor\u003c\/a\u003e listing and the pump end on our \u003ca href=\"\/products\/grundfos-16s-sp-4-in-submersible-pump-end\"\u003eGrundfos 16S SP pump end\u003c\/a\u003e listing.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"background:#E1E3E6;border-left:3px solid #B8BDC4;padding:8px 14px;font-size:11.5px;color:#4A4A4F;margin-top:14px;line-height:1.5\"\u003eGenuine Grundfos equipment, factory-new in original packaging — sold and supported by Watermain Supply, an independent industrial supplier.\u003c\/div\u003e\n\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eWarranty\u003c\/div\u003e\n\u003cdiv class=\"gs-lead\"\u003e\u003cp\u003e24 months from date of installation, but not more than 30 months from date of manufacture. In Grundfos's words, products are “warranted to the original user only to be free of defects in material and workmanship”; the full terms are in the installation and operating instructions on the Data Sheet tab.\u003c\/p\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eSpecifications\u003c\/div\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage order number\u003c\/td\u003e\n\u003ctd\u003e93336025\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePump end\u003c\/td\u003e\n\u003ctd\u003e16S10-10, 16 GPM rated, AISI 304 stainless steel (10010010)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor\u003c\/td\u003e\n\u003ctd\u003e1 HP, 4 in, three-phase MS402 (96465627)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrive\u003c\/td\u003e\n\u003ctd\u003eCUE 100 10, 6 A max motor service-factor current, NEMA 4X \/ IP66 outdoor (93281860)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrive supply\u003c\/td\u003e\n\u003ctd\u003e230 V, single phase in; three phase out to the motor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure transducer\u003c\/td\u003e\n\u003ctd\u003eIncluded with the drive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDischarge\u003c\/td\u003e\n\u003ctd\u003e1-1\/4 in NPT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum well\u003c\/td\u003e\n\u003ctd\u003e4 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping weight\u003c\/td\u003e\n\u003ctd\u003e57 lb, complete package\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"font-size:12.5px;color:#9B9EA3;margin-top:8px;line-height:1.55\"\u003eSource: Grundfos US groundwater price list, January 2026 (4 in CUE 100 packages and CUE 100 drives).\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eModels \u0026amp; Performance — Will It Do What You Need?\u003c\/div\u003e\n\u003cp style=\"font-size:13.5px;margin-bottom:10px\"\u003eThe first table reads like the curve: the head the pump adds from shut-off to the end of its curve. The second shows what it delivers while the drive holds 40, 50 or 60 PSI at your pumping water level.\u003c\/p\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003cth\u003eHP\u003c\/th\u003e\n\u003cth\u003e0 GPM (Shut-off)\u003c\/th\u003e\n\u003cth\u003e4.1 GPM\u003c\/th\u003e\n\u003cth\u003e10.3 GPM\u003c\/th\u003e\n\u003cth\u003e16 GPM (Rated)\u003c\/th\u003e\n\u003cth\u003e20.6 GPM (Max)\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e16S10-10\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003ctd\u003e299\u003c\/td\u003e\n\u003ctd\u003e283\u003c\/td\u003e\n\u003ctd\u003e252\u003c\/td\u003e\n\u003ctd\u003e223\u003c\/td\u003e\n\u003ctd\u003e135\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"font-size:12.5px;color:#9B9EA3;margin-top:8px;line-height:1.55\"\u003eTotal head in feet. The shut-off and flow columns are read from the Grundfos 60 Hz curve for the 16S10-10, digitized from the published vector curve in the Grundfos SP 16S data sheet (60 Hz), at the nearest published point and rounded down. The (Rated) column is the nominal head Grundfos prints for the 16S10-10 at 16 GPM, verbatim. 1 ft of head = 0.433 PSI. Full curves are in the product images and on the Data Sheet tab.\u003c\/p\u003e\n\u003cp style=\"font-size:13.5px;margin-bottom:10px;margin-top:18px\"\u003e\u003cstrong\u003eWhat It Delivers at Your Set Pressure\u003c\/strong\u003e (GPM by depth to water)\u003c\/p\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSet pressure\u003c\/th\u003e\n\u003cth\u003e20 ft\u003c\/th\u003e\n\u003cth\u003e60 ft\u003c\/th\u003e\n\u003cth\u003e80 ft\u003c\/th\u003e\n\u003cth\u003e100 ft\u003c\/th\u003e\n\u003cth\u003e140 ft\u003c\/th\u003e\n\u003cth\u003e180 ft\u003c\/th\u003e\n\u003cth\u003e200 ft\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e40 PSI\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e19.1\u003c\/td\u003e\n\u003ctd\u003e18\u003c\/td\u003e\n\u003ctd\u003e16.4\u003c\/td\u003e\n\u003ctd\u003e12.2\u003c\/td\u003e\n\u003ctd\u003e5.9\u003c\/td\u003e\n\u003ctd\u003e2.3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e50 PSI\u003c\/td\u003e\n\u003ctd\u003e20\u003c\/td\u003e\n\u003ctd\u003e17.7\u003c\/td\u003e\n\u003ctd\u003e16.3\u003c\/td\u003e\n\u003ctd\u003e14.2\u003c\/td\u003e\n\u003ctd\u003e8.8\u003c\/td\u003e\n\u003ctd\u003e2.8\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e60 PSI\u003c\/td\u003e\n\u003ctd\u003e18.8\u003c\/td\u003e\n\u003ctd\u003e15.8\u003c\/td\u003e\n\u003ctd\u003e14.1\u003c\/td\u003e\n\u003ctd\u003e11.3\u003c\/td\u003e\n\u003ctd\u003e4.8\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"font-size:12.5px;color:#9B9EA3;margin-top:8px;line-height:1.55\"\u003eGPM by depth to pumping water level, verbatim from the Grundfos 16 gpm easy selection chart for the 16S10-10 (SQ, SQE, SmartFlo and SP data booklet, 60 Hz), at full speed: the most the pump delivers while the CUE 100 holds that pressure; at lower demand the drive slows the pump. Riser and pipe friction are not included. A dash means Grundfos prints no figure: on the shallow side the flow is past the chart range, on the deep side the pump cannot hold that pressure.\u003c\/p\u003e\n\u003cdiv style=\"display:flex;flex-wrap:wrap;gap:10px;margin:22px 0 4px\"\u003e\n\u003ca href=\"\/pages\/submersible-well-pump-sizing-calculator\" style=\"flex:1 1 200px;text-align:center;display:block;background:#B3122A;color:#ffffff;font-family:Arial Black,Arial,sans-serif;font-size:12px;text-transform:uppercase;letter-spacing:1.2px;padding:11px 18px;text-decoration:none\"\u003eSubmersible Calculator\u003c\/a\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eBefore You Buy — The Limits That Decide the Fit\u003c\/div\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eCheck\u003c\/th\u003e\n\u003cth\u003eWhat to confirm\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eWell size\u003c\/td\u003e\n\u003ctd\u003e4 in or larger casing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower\u003c\/td\u003e\n\u003ctd\u003e230 V single-phase supply to the drive; the motor runs only from the drive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWater\u003c\/td\u003e\n\u003ctd\u003eUp to 104°F with at least 0.25 ft\/s flowing past the 4 in motor; drinking water up to 86°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure tank\u003c\/td\u003e\n\u003ctd\u003eA diaphragm tank sized to the CUE 100 instructions, between the well and the first tap\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrive location\u003c\/td\u003e\n\u003ctd\u003eWall-mounted, indoors or outdoors (NEMA 4X); keep within the drop-cable length the CUE 100 instructions allow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSand\u003c\/td\u003e\n\u003ctd\u003eUp to 50 ppm for SP 5S-25S\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eMaterials of Construction\u003c\/div\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003ePart\u003c\/th\u003e\n\u003cth\u003eMaterial\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eImpellers, chambers, strainer, cable guard\u003c\/td\u003e\n\u003ctd\u003eAISI 304 stainless steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePump shaft\u003c\/td\u003e\n\u003ctd\u003eStainless steel, EN 1.4057\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBearings\u003c\/td\u003e\n\u003ctd\u003eNBR elastomer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor\u003c\/td\u003e\n\u003ctd\u003eWater-filled Grundfos MS submersible motor, stainless steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"font-size:12.5px;color:#9B9EA3;margin-top:8px;line-height:1.55\"\u003eSource: Grundfos SP data booklet, standard S construction.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"gs-contact\"\u003eFor engineering-led sizing and selection support or a factory submittal, email \u003ca href=\"mailto:sales@watermainsupply.com\"\u003esales@watermainsupply.com\u003c\/a\u003e or call \u003ca href=\"tel:18885104036\"\u003e1-888.510.4036\u003c\/a\u003e.\u003cbr\u003e© Watermain Supply — A division of E4 Industrial LLC\u003c\/div\u003e\n\n\u003c\/div\u003e\n\u003ch5\u003eData Sheet\u003c\/h5\u003e\u003cdiv class=\"gs\"\u003e\u003cdiv class=\"gs-dl\"\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0264\/1913\/4527\/files\/CUE_100_product_Leaflet_v3_QR.pdf?v=1788919445\" target=\"_blank\" rel=\"noopener\"\u003eCUE 100 Product Leaflet\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0264\/1913\/4527\/files\/93232651_07.2024_CUE_100_online.pdf?v=1788919445\" target=\"_blank\" rel=\"noopener\"\u003eCUE 100 Installation and Operating Instructions\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0264\/1913\/4527\/files\/LSPSL002.pdf?v=1788919444\" target=\"_blank\" rel=\"noopener\"\u003eGrundfos SP Submersible Pumps Data Booklet\u003c\/a\u003e\n\u003c\/div\u003e\u003c\/div\u003e\u003ch5\u003eVideos\u003c\/h5\u003e\u003cdiv class=\"gs\"\u003e\u003cdiv class=\"gs-sec\" style=\"margin-top:6px\"\u003e\u003cdiv style=\"display:grid;grid-template-columns:repeat(auto-fit,minmax(320px,1fr));gap:16px;max-width:900px\"\u003e\n\u003cdiv style=\"position:relative;padding-bottom:56.25%;height:0;overflow:hidden\"\u003e\u003ciframe src=\"https:\/\/www.youtube.com\/embed\/JSZLNfMMIpo\" title=\"Grundfos CUE 100 overview\" style=\"position:absolute;top:0;left:0;width:100%;height:100%;border:0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture\" allowfullscreen\u003e\u003c\/iframe\u003e\u003c\/div\u003e\n\u003cdiv style=\"position:relative;padding-bottom:56.25%;height:0;overflow:hidden\"\u003e\u003ciframe src=\"https:\/\/www.youtube.com\/embed\/s-6jNIZKvAI\" title=\"Grundfos CUE 100 setup demonstration\" style=\"position:absolute;top:0;left:0;width:100%;height:100%;border:0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture\" allowfullscreen\u003e\u003c\/iframe\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/div\u003e\u003c\/div\u003e\u003ch5\u003eUnyConnect App\u003c\/h5\u003e\u003cdiv class=\"gs\"\u003e\u003cdiv class=\"gs-sec\" style=\"margin-top:6px\"\u003e\n\u003cdiv class=\"gs-h\"\u003eSet Up At The Drive Or From Your Phone\u003c\/div\u003e\n\u003cdiv class=\"gs-lead\"\u003e\u003cp\u003eThe CUE 100 is set up at the drive keypad, or over Bluetooth with the free UnyConnect app on an iOS or Android phone. UnyConnect reads status and live operating data, sets the pressure setpoint and control parameters, and shows diagnostic alarms. Remote monitoring away from the wellhead requires the appropriate integration.\u003c\/p\u003e\u003c\/div\u003e\n\u003cdiv style=\"margin-top:16px\"\u003e\n\u003ca href=\"https:\/\/apps.apple.com\/us\/app\/unyconnect\/id6443696303\" target=\"_blank\" rel=\"noopener\" style=\"display:inline-block;background:#B3122A;color:#fff!important;font-family:Arial Black,Arial,sans-serif;font-size:13px;letter-spacing:1px;text-transform:uppercase;text-decoration:none;padding:12px 24px;border-radius:999px;margin:0 10px 10px 0\"\u003eDownload for iOS\u003c\/a\u003e\u003ca href=\"https:\/\/play.google.com\/store\/apps\/details?id=com.nastec.unyconnect\u0026amp;pcampaignid=web_share\" target=\"_blank\" rel=\"noopener\" style=\"display:inline-block;background:#4A4A4F;color:#fff!important;font-family:Arial Black,Arial,sans-serif;font-size:13px;letter-spacing:1px;text-transform:uppercase;text-decoration:none;padding:12px 24px;border-radius:999px;margin:0 10px 10px 0\"\u003eDownload for Android\u003c\/a\u003e\n\u003c\/div\u003e\n\u003cp style=\"font-size:12px;color:#9B9EA3;margin-top:12px\"\u003eUnyConnect is a free app for the CUE 100 drive. Bluetooth must be enabled on the CUE 100 before pairing.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/div\u003e\u003c!-- \/TABS --\u003e","brand":"Grundfos","offers":[{"title":"Default Title","offer_id":47465163030703,"sku":"93336025","price":3080.69,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0264\/1913\/4527\/files\/Grundfox_4_in_CUE_100_Sumbersible_pump_motor_controller_package.webp?v=1788919471"},{"product_id":"grundfos-16s15-14-cue-100-well-pump-package","title":"Grundfos 16S15-14 CUE 100 Constant Pressure Well Pump Package - 1-1\/2 HP, 313 ft at 16 GPM, 230V 1Ph Input - 93336027","description":"\u003c!-- TABS --\u003e\n\u003ch5\u003eDescription\u003c\/h5\u003e\n\u003cdiv class=\"gs\"\u003e\n\n\u003cdiv class=\"gs-head\"\u003e\n\u003cdiv class=\"gs-eyebrow\"\u003eGrundfos · 4 in Constant Pressure Well Pump Package\u003c\/div\u003e\n\u003cdiv class=\"gs-title\"\u003e16S15-14 CUE 100\u003c\/div\u003e\n\u003cdiv class=\"gs-sub\"\u003eConstant-pressure well water package under one Grundfos order number: a 16S15-14 stainless steel SP pump end, a 1-1\/2 HP 4 in three-phase motor and a CUE 100 20 drive with its pressure transducer. Runs from 230 V single-phase service.\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"gs-badges\"\u003e\n\u003cdiv class=\"gs-badge\" style=\"background:#B3122A;color:#FFFFFF;border-color:#B3122A\"\u003e16 GPM Rated Flow\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003e313 ft at 16 GPM\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003e1-1\/2 HP\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003e230V 1Ph In · 3Ph Motor\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003eConstant Pressure · Transducer Included\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003e4 in Min. Well\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003e1-1\/4 in NPT Discharge\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003eNEMA 4X Outdoor Drive\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003e62 lb Ship Weight (Package)\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eOverview\u003c\/div\u003e\n\u003cdiv class=\"gs-lead\"\u003e\n\u003cp\u003eThis package brings together the three Grundfos components of a constant-pressure well system: the 16S15-14 pump end, a 1-1\/2 HP 4 in three-phase submersible motor and the CUE 100 variable-frequency drive. The drive reads the included pressure transducer and changes pump speed to hold the pressure you set as taps open and close, so the house sees steady pressure instead of a pressure switch's swing.\u003c\/p\u003e\n\u003cp\u003eThe CUE 100 takes 230 V single-phase power and makes three-phase power for the motor, so you get a three-phase pump's smooth, soft-started running on ordinary single-phase service. The drive is NEMA 4X \/ IP66 for outdoor mounting and is set up at its keypad or over Bluetooth with the free UnyConnect app.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSteady pressure.\u003c\/strong\u003e The drive holds the setpoint from one tap to full flow and slows the pump when demand drops.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStainless steel SP hydraulics.\u003c\/strong\u003e AISI 304 impellers, chambers and outer parts, a built-in check valve and a sand-handling bearing design.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDiagnostics at the wellhead.\u003c\/strong\u003e Time- and date-stamped alarms and warnings at the drive and in the app; Modbus, BACnet and Bluetooth connectivity.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"background:#FFFFFF;border:1px solid #C7CBD1;border-top:3px solid #B3122A;padding:12px 16px 12px;margin:16px 0 4px;font-size:13.5px;line-height:1.55;color:#4A4A4F\"\u003e\n\u003cdiv style=\"font-family:Arial Black,Arial,sans-serif;font-size:11px;letter-spacing:1.2px;text-transform:uppercase;color:#B3122A;margin-bottom:8px\"\u003eWhat Ships and What It Needs to Run\u003c\/div\u003e\n\u003cp style=\"margin:0 0 6px\"\u003e\u003cstrong style=\"color:#B3122A\"\u003eIncluded, under order number 93336027:\u003c\/strong\u003e the 16S15-14 SP pump end (10010014), a 1-1\/2 HP 4 in three-phase MS402 motor (96465629) and the CUE 100 20 drive (92939786) with its pressure transducer. Grundfos lists them as three components of one package.\u003c\/p\u003e\n\u003cp style=\"margin:0 0 6px\"\u003e\u003cstrong style=\"color:#B3122A\"\u003eRequired, ordered separately:\u003c\/strong\u003e a diaphragm pressure tank sized to the CUE 100 instructions, drop pipe, submersible drop cable and splice kit for your setting depth, and a 230 V single-phase supply and breaker for the drive.\u003c\/p\u003e\n\u003cp style=\"margin:0 0 6px\"\u003e\u003cstrong style=\"color:#B3122A\"\u003eNever connect the motor straight to the supply.\u003c\/strong\u003e It is a three-phase motor and runs only from the CUE 100.\u003c\/p\u003e\n\u003cp style=\"margin:0\"\u003e\u003cstrong style=\"color:#B3122A\"\u003eReplacement parts:\u003c\/strong\u003e the drive alone is on our \u003ca href=\"\/products\/grundfos-cue-100-constant-pressure-drive\"\u003eGrundfos CUE 100 Constant Pressure Drive\u003c\/a\u003e listing, the motor on our \u003ca href=\"\/products\/grundfos-ms-4-in-submersible-motor\"\u003eGrundfos MS 4 in motor\u003c\/a\u003e listing and the pump end on our \u003ca href=\"\/products\/grundfos-16s-sp-4-in-submersible-pump-end\"\u003eGrundfos 16S SP pump end\u003c\/a\u003e listing.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"background:#E1E3E6;border-left:3px solid #B8BDC4;padding:8px 14px;font-size:11.5px;color:#4A4A4F;margin-top:14px;line-height:1.5\"\u003eGenuine Grundfos equipment, factory-new in original packaging — sold and supported by Watermain Supply, an independent industrial supplier.\u003c\/div\u003e\n\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eWarranty\u003c\/div\u003e\n\u003cdiv class=\"gs-lead\"\u003e\u003cp\u003e24 months from date of installation, but not more than 30 months from date of manufacture. In Grundfos's words, products are “warranted to the original user only to be free of defects in material and workmanship”; the full terms are in the installation and operating instructions on the Data Sheet tab.\u003c\/p\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eSpecifications\u003c\/div\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage order number\u003c\/td\u003e\n\u003ctd\u003e93336027\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePump end\u003c\/td\u003e\n\u003ctd\u003e16S15-14, 16 GPM rated, AISI 304 stainless steel (10010014)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor\u003c\/td\u003e\n\u003ctd\u003e1-1\/2 HP, 4 in, three-phase MS402 (96465629)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrive\u003c\/td\u003e\n\u003ctd\u003eCUE 100 20, 9.5 A max motor service-factor current, NEMA 4X \/ IP66 outdoor (92939786)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrive supply\u003c\/td\u003e\n\u003ctd\u003e230 V, single phase in; three phase out to the motor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure transducer\u003c\/td\u003e\n\u003ctd\u003eIncluded with the drive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDischarge\u003c\/td\u003e\n\u003ctd\u003e1-1\/4 in NPT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum well\u003c\/td\u003e\n\u003ctd\u003e4 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping weight\u003c\/td\u003e\n\u003ctd\u003e62 lb, complete package\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"font-size:12.5px;color:#9B9EA3;margin-top:8px;line-height:1.55\"\u003eSource: Grundfos US groundwater price list, January 2026 (4 in CUE 100 packages and CUE 100 drives).\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eModels \u0026amp; Performance — Will It Do What You Need?\u003c\/div\u003e\n\u003cp style=\"font-size:13.5px;margin-bottom:10px\"\u003eThe first table reads like the curve: the head the pump adds from shut-off to the end of its curve. The second shows what it delivers while the drive holds 40, 50 or 60 PSI at your pumping water level.\u003c\/p\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003cth\u003eHP\u003c\/th\u003e\n\u003cth\u003e0 GPM (Shut-off)\u003c\/th\u003e\n\u003cth\u003e4.1 GPM\u003c\/th\u003e\n\u003cth\u003e10.3 GPM\u003c\/th\u003e\n\u003cth\u003e16 GPM (Rated)\u003c\/th\u003e\n\u003cth\u003e20.6 GPM (Max)\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e16S15-14\u003c\/td\u003e\n\u003ctd\u003e1-1\/2\u003c\/td\u003e\n\u003ctd\u003e419\u003c\/td\u003e\n\u003ctd\u003e397\u003c\/td\u003e\n\u003ctd\u003e354\u003c\/td\u003e\n\u003ctd\u003e313\u003c\/td\u003e\n\u003ctd\u003e190\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"font-size:12.5px;color:#9B9EA3;margin-top:8px;line-height:1.55\"\u003eTotal head in feet. The shut-off and flow columns are read from the Grundfos 60 Hz curve for the 16S15-14, digitized from the published vector curve in the Grundfos SP 16S data sheet (60 Hz), at the nearest published point and rounded down. The (Rated) column is the nominal head Grundfos prints for the 16S15-14 at 16 GPM, verbatim. 1 ft of head = 0.433 PSI. Full curves are in the product images and on the Data Sheet tab.\u003c\/p\u003e\n\u003cp style=\"font-size:13.5px;margin-bottom:10px;margin-top:18px\"\u003e\u003cstrong\u003eWhat It Delivers at Your Set Pressure\u003c\/strong\u003e (GPM by depth to water)\u003c\/p\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSet pressure\u003c\/th\u003e\n\u003cth\u003e40 ft\u003c\/th\u003e\n\u003cth\u003e80 ft\u003c\/th\u003e\n\u003cth\u003e120 ft\u003c\/th\u003e\n\u003cth\u003e160 ft\u003c\/th\u003e\n\u003cth\u003e220 ft\u003c\/th\u003e\n\u003cth\u003e260 ft\u003c\/th\u003e\n\u003cth\u003e300 ft\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e40 PSI\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e20.6\u003c\/td\u003e\n\u003ctd\u003e19.1\u003c\/td\u003e\n\u003ctd\u003e17.4\u003c\/td\u003e\n\u003ctd\u003e13.3\u003c\/td\u003e\n\u003ctd\u003e9.3\u003c\/td\u003e\n\u003ctd\u003e4.3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e50 PSI\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e19.8\u003c\/td\u003e\n\u003ctd\u003e18.2\u003c\/td\u003e\n\u003ctd\u003e16.1\u003c\/td\u003e\n\u003ctd\u003e11.2\u003c\/td\u003e\n\u003ctd\u003e6.5\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e60 PSI\u003c\/td\u003e\n\u003ctd\u003e20.3\u003c\/td\u003e\n\u003ctd\u003e18.8\u003c\/td\u003e\n\u003ctd\u003e17.1\u003c\/td\u003e\n\u003ctd\u003e14.5\u003c\/td\u003e\n\u003ctd\u003e8.6\u003c\/td\u003e\n\u003ctd\u003e3.4\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"font-size:12.5px;color:#9B9EA3;margin-top:8px;line-height:1.55\"\u003eGPM by depth to pumping water level, verbatim from the Grundfos 16 gpm easy selection chart for the 16S15-14 (SQ, SQE, SmartFlo and SP data booklet, 60 Hz), at full speed: the most the pump delivers while the CUE 100 holds that pressure; at lower demand the drive slows the pump. Riser and pipe friction are not included. A dash means Grundfos prints no figure: on the shallow side the flow is past the chart range, on the deep side the pump cannot hold that pressure.\u003c\/p\u003e\n\u003cdiv style=\"display:flex;flex-wrap:wrap;gap:10px;margin:22px 0 4px\"\u003e\n\u003ca href=\"\/pages\/submersible-well-pump-sizing-calculator\" style=\"flex:1 1 200px;text-align:center;display:block;background:#B3122A;color:#ffffff;font-family:Arial Black,Arial,sans-serif;font-size:12px;text-transform:uppercase;letter-spacing:1.2px;padding:11px 18px;text-decoration:none\"\u003eSubmersible Calculator\u003c\/a\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eBefore You Buy — The Limits That Decide the Fit\u003c\/div\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eCheck\u003c\/th\u003e\n\u003cth\u003eWhat to confirm\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eWell size\u003c\/td\u003e\n\u003ctd\u003e4 in or larger casing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower\u003c\/td\u003e\n\u003ctd\u003e230 V single-phase supply to the drive; the motor runs only from the drive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWater\u003c\/td\u003e\n\u003ctd\u003eUp to 104°F with at least 0.25 ft\/s flowing past the 4 in motor; drinking water up to 86°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure tank\u003c\/td\u003e\n\u003ctd\u003eA diaphragm tank sized to the CUE 100 instructions, between the well and the first tap\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrive location\u003c\/td\u003e\n\u003ctd\u003eWall-mounted, indoors or outdoors (NEMA 4X); keep within the drop-cable length the CUE 100 instructions allow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSand\u003c\/td\u003e\n\u003ctd\u003eUp to 50 ppm for SP 5S-25S\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eMaterials of Construction\u003c\/div\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003ePart\u003c\/th\u003e\n\u003cth\u003eMaterial\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eImpellers, chambers, strainer, cable guard\u003c\/td\u003e\n\u003ctd\u003eAISI 304 stainless steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePump shaft\u003c\/td\u003e\n\u003ctd\u003eStainless steel, EN 1.4057\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBearings\u003c\/td\u003e\n\u003ctd\u003eNBR elastomer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor\u003c\/td\u003e\n\u003ctd\u003eWater-filled Grundfos MS submersible motor, stainless steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"font-size:12.5px;color:#9B9EA3;margin-top:8px;line-height:1.55\"\u003eSource: Grundfos SP data booklet, standard S construction.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"gs-contact\"\u003eFor engineering-led sizing and selection support or a factory submittal, email \u003ca href=\"mailto:sales@watermainsupply.com\"\u003esales@watermainsupply.com\u003c\/a\u003e or call \u003ca href=\"tel:18885104036\"\u003e1-888.510.4036\u003c\/a\u003e.\u003cbr\u003e© Watermain Supply — A division of E4 Industrial LLC\u003c\/div\u003e\n\n\u003c\/div\u003e\n\u003ch5\u003eData Sheet\u003c\/h5\u003e\u003cdiv class=\"gs\"\u003e\u003cdiv class=\"gs-dl\"\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0264\/1913\/4527\/files\/CUE_100_product_Leaflet_v3_QR.pdf?v=1788919445\" target=\"_blank\" rel=\"noopener\"\u003eCUE 100 Product Leaflet\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0264\/1913\/4527\/files\/93232651_07.2024_CUE_100_online.pdf?v=1788919445\" target=\"_blank\" rel=\"noopener\"\u003eCUE 100 Installation and Operating Instructions\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0264\/1913\/4527\/files\/LSPSL002.pdf?v=1788919444\" target=\"_blank\" rel=\"noopener\"\u003eGrundfos SP Submersible Pumps Data Booklet\u003c\/a\u003e\n\u003c\/div\u003e\u003c\/div\u003e\u003ch5\u003eVideos\u003c\/h5\u003e\u003cdiv class=\"gs\"\u003e\u003cdiv class=\"gs-sec\" style=\"margin-top:6px\"\u003e\u003cdiv style=\"display:grid;grid-template-columns:repeat(auto-fit,minmax(320px,1fr));gap:16px;max-width:900px\"\u003e\n\u003cdiv style=\"position:relative;padding-bottom:56.25%;height:0;overflow:hidden\"\u003e\u003ciframe src=\"https:\/\/www.youtube.com\/embed\/JSZLNfMMIpo\" title=\"Grundfos CUE 100 overview\" style=\"position:absolute;top:0;left:0;width:100%;height:100%;border:0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture\" allowfullscreen\u003e\u003c\/iframe\u003e\u003c\/div\u003e\n\u003cdiv style=\"position:relative;padding-bottom:56.25%;height:0;overflow:hidden\"\u003e\u003ciframe src=\"https:\/\/www.youtube.com\/embed\/s-6jNIZKvAI\" title=\"Grundfos CUE 100 setup demonstration\" style=\"position:absolute;top:0;left:0;width:100%;height:100%;border:0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture\" allowfullscreen\u003e\u003c\/iframe\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/div\u003e\u003c\/div\u003e\u003ch5\u003eUnyConnect App\u003c\/h5\u003e\u003cdiv class=\"gs\"\u003e\u003cdiv class=\"gs-sec\" style=\"margin-top:6px\"\u003e\n\u003cdiv class=\"gs-h\"\u003eSet Up At The Drive Or From Your Phone\u003c\/div\u003e\n\u003cdiv class=\"gs-lead\"\u003e\u003cp\u003eThe CUE 100 is set up at the drive keypad, or over Bluetooth with the free UnyConnect app on an iOS or Android phone. UnyConnect reads status and live operating data, sets the pressure setpoint and control parameters, and shows diagnostic alarms. Remote monitoring away from the wellhead requires the appropriate integration.\u003c\/p\u003e\u003c\/div\u003e\n\u003cdiv style=\"margin-top:16px\"\u003e\n\u003ca href=\"https:\/\/apps.apple.com\/us\/app\/unyconnect\/id6443696303\" target=\"_blank\" rel=\"noopener\" style=\"display:inline-block;background:#B3122A;color:#fff!important;font-family:Arial Black,Arial,sans-serif;font-size:13px;letter-spacing:1px;text-transform:uppercase;text-decoration:none;padding:12px 24px;border-radius:999px;margin:0 10px 10px 0\"\u003eDownload for iOS\u003c\/a\u003e\u003ca href=\"https:\/\/play.google.com\/store\/apps\/details?id=com.nastec.unyconnect\u0026amp;pcampaignid=web_share\" target=\"_blank\" rel=\"noopener\" style=\"display:inline-block;background:#4A4A4F;color:#fff!important;font-family:Arial Black,Arial,sans-serif;font-size:13px;letter-spacing:1px;text-transform:uppercase;text-decoration:none;padding:12px 24px;border-radius:999px;margin:0 10px 10px 0\"\u003eDownload for Android\u003c\/a\u003e\n\u003c\/div\u003e\n\u003cp style=\"font-size:12px;color:#9B9EA3;margin-top:12px\"\u003eUnyConnect is a free app for the CUE 100 drive. Bluetooth must be enabled on the CUE 100 before pairing.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/div\u003e\u003c!-- \/TABS --\u003e","brand":"Grundfos","offers":[{"title":"Default Title","offer_id":47465163063471,"sku":"93336027","price":3560.09,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0264\/1913\/4527\/files\/Grundfox_4_in_CUE_100_Sumbersible_pump_motor_controller_package.webp?v=1788919471"},{"product_id":"grundfos-16s20-18-cue-100-well-pump-package","title":"Grundfos 16S20-18 CUE 100 Constant Pressure Well Pump Package - 2 HP, 397 ft at 16 GPM, 230V 1Ph Input - 93336045","description":"\u003c!-- TABS --\u003e\n\u003ch5\u003eDescription\u003c\/h5\u003e\n\u003cdiv class=\"gs\"\u003e\n\n\u003cdiv class=\"gs-head\"\u003e\n\u003cdiv class=\"gs-eyebrow\"\u003eGrundfos · 4 in Constant Pressure Well Pump Package\u003c\/div\u003e\n\u003cdiv class=\"gs-title\"\u003e16S20-18 CUE 100\u003c\/div\u003e\n\u003cdiv class=\"gs-sub\"\u003eConstant-pressure well water package under one Grundfos order number: a 16S20-18 stainless steel SP pump end, a 2 HP 4 in three-phase motor and a CUE 100 20 drive with its pressure transducer. Runs from 230 V single-phase service.\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"gs-badges\"\u003e\n\u003cdiv class=\"gs-badge\" style=\"background:#B3122A;color:#FFFFFF;border-color:#B3122A\"\u003e16 GPM Rated Flow\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003e397 ft at 16 GPM\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003e2 HP\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003e230V 1Ph In · 3Ph Motor\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003eConstant Pressure · Transducer Included\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003e4 in Min. Well\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003e1-1\/4 in NPT Discharge\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003eNEMA 4X Outdoor Drive\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003e68 lb Ship Weight (Package)\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eOverview\u003c\/div\u003e\n\u003cdiv class=\"gs-lead\"\u003e\n\u003cp\u003eThis package brings together the three Grundfos components of a constant-pressure well system: the 16S20-18 pump end, a 2 HP 4 in three-phase submersible motor and the CUE 100 variable-frequency drive. The drive reads the included pressure transducer and changes pump speed to hold the pressure you set as taps open and close, so the house sees steady pressure instead of a pressure switch's swing.\u003c\/p\u003e\n\u003cp\u003eThe CUE 100 takes 230 V single-phase power and makes three-phase power for the motor, so you get a three-phase pump's smooth, soft-started running on ordinary single-phase service. The drive is NEMA 4X \/ IP66 for outdoor mounting and is set up at its keypad or over Bluetooth with the free UnyConnect app.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSteady pressure.\u003c\/strong\u003e The drive holds the setpoint from one tap to full flow and slows the pump when demand drops.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStainless steel SP hydraulics.\u003c\/strong\u003e AISI 304 impellers, chambers and outer parts, a built-in check valve and a sand-handling bearing design.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDiagnostics at the wellhead.\u003c\/strong\u003e Time- and date-stamped alarms and warnings at the drive and in the app; Modbus, BACnet and Bluetooth connectivity.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"background:#FFFFFF;border:1px solid #C7CBD1;border-top:3px solid #B3122A;padding:12px 16px 12px;margin:16px 0 4px;font-size:13.5px;line-height:1.55;color:#4A4A4F\"\u003e\n\u003cdiv style=\"font-family:Arial Black,Arial,sans-serif;font-size:11px;letter-spacing:1.2px;text-transform:uppercase;color:#B3122A;margin-bottom:8px\"\u003eWhat Ships and What It Needs to Run\u003c\/div\u003e\n\u003cp style=\"margin:0 0 6px\"\u003e\u003cstrong style=\"color:#B3122A\"\u003eIncluded, under order number 93336045:\u003c\/strong\u003e the 16S20-18 SP pump end (10010018), a 2 HP 4 in three-phase MS402 motor (96465630) and the CUE 100 20 drive (92939786) with its pressure transducer. Grundfos lists them as three components of one package.\u003c\/p\u003e\n\u003cp style=\"margin:0 0 6px\"\u003e\u003cstrong style=\"color:#B3122A\"\u003eRequired, ordered separately:\u003c\/strong\u003e a diaphragm pressure tank sized to the CUE 100 instructions, drop pipe, submersible drop cable and splice kit for your setting depth, and a 230 V single-phase supply and breaker for the drive.\u003c\/p\u003e\n\u003cp style=\"margin:0 0 6px\"\u003e\u003cstrong style=\"color:#B3122A\"\u003eNever connect the motor straight to the supply.\u003c\/strong\u003e It is a three-phase motor and runs only from the CUE 100.\u003c\/p\u003e\n\u003cp style=\"margin:0\"\u003e\u003cstrong style=\"color:#B3122A\"\u003eReplacement parts:\u003c\/strong\u003e the drive alone is on our \u003ca href=\"\/products\/grundfos-cue-100-constant-pressure-drive\"\u003eGrundfos CUE 100 Constant Pressure Drive\u003c\/a\u003e listing, the motor on our \u003ca href=\"\/products\/grundfos-ms-4-in-submersible-motor\"\u003eGrundfos MS 4 in motor\u003c\/a\u003e listing and the pump end on our \u003ca href=\"\/products\/grundfos-16s-sp-4-in-submersible-pump-end\"\u003eGrundfos 16S SP pump end\u003c\/a\u003e listing.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"background:#E1E3E6;border-left:3px solid #B8BDC4;padding:8px 14px;font-size:11.5px;color:#4A4A4F;margin-top:14px;line-height:1.5\"\u003eGenuine Grundfos equipment, factory-new in original packaging — sold and supported by Watermain Supply, an independent industrial supplier.\u003c\/div\u003e\n\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eWarranty\u003c\/div\u003e\n\u003cdiv class=\"gs-lead\"\u003e\u003cp\u003e24 months from date of installation, but not more than 30 months from date of manufacture. In Grundfos's words, products are “warranted to the original user only to be free of defects in material and workmanship”; the full terms are in the installation and operating instructions on the Data Sheet tab.\u003c\/p\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eSpecifications\u003c\/div\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage order number\u003c\/td\u003e\n\u003ctd\u003e93336045\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePump end\u003c\/td\u003e\n\u003ctd\u003e16S20-18, 16 GPM rated, AISI 304 stainless steel (10010018)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor\u003c\/td\u003e\n\u003ctd\u003e2 HP, 4 in, three-phase MS402 (96465630)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrive\u003c\/td\u003e\n\u003ctd\u003eCUE 100 20, 9.5 A max motor service-factor current, NEMA 4X \/ IP66 outdoor (92939786)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrive supply\u003c\/td\u003e\n\u003ctd\u003e230 V, single phase in; three phase out to the motor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure transducer\u003c\/td\u003e\n\u003ctd\u003eIncluded with the drive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDischarge\u003c\/td\u003e\n\u003ctd\u003e1-1\/4 in NPT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum well\u003c\/td\u003e\n\u003ctd\u003e4 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping weight\u003c\/td\u003e\n\u003ctd\u003e68 lb, complete package\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"font-size:12.5px;color:#9B9EA3;margin-top:8px;line-height:1.55\"\u003eSource: Grundfos US groundwater price list, January 2026 (4 in CUE 100 packages and CUE 100 drives).\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eModels \u0026amp; Performance — Will It Do What You Need?\u003c\/div\u003e\n\u003cp style=\"font-size:13.5px;margin-bottom:10px\"\u003eThe first table reads like the curve: the head the pump adds from shut-off to the end of its curve. The second shows what it delivers while the drive holds 40, 50 or 60 PSI at your pumping water level.\u003c\/p\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003cth\u003eHP\u003c\/th\u003e\n\u003cth\u003e0 GPM (Shut-off)\u003c\/th\u003e\n\u003cth\u003e4.1 GPM\u003c\/th\u003e\n\u003cth\u003e10.3 GPM\u003c\/th\u003e\n\u003cth\u003e16 GPM (Rated)\u003c\/th\u003e\n\u003cth\u003e20.6 GPM (Max)\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e16S20-18\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e536\u003c\/td\u003e\n\u003ctd\u003e508\u003c\/td\u003e\n\u003ctd\u003e451\u003c\/td\u003e\n\u003ctd\u003e397\u003c\/td\u003e\n\u003ctd\u003e238\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"font-size:12.5px;color:#9B9EA3;margin-top:8px;line-height:1.55\"\u003eTotal head in feet. The shut-off and flow columns are read from the Grundfos 60 Hz curve for the 16S20-18, digitized from the published vector curve in the Grundfos SP 16S data sheet (60 Hz), at the nearest published point and rounded down. The (Rated) column is the nominal head Grundfos prints for the 16S20-18 at 16 GPM, verbatim. 1 ft of head = 0.433 PSI. Full curves are in the product images and on the Data Sheet tab.\u003c\/p\u003e\n\u003cp style=\"font-size:13.5px;margin-bottom:10px;margin-top:18px\"\u003e\u003cstrong\u003eWhat It Delivers at Your Set Pressure\u003c\/strong\u003e (GPM by depth to water)\u003c\/p\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSet pressure\u003c\/th\u003e\n\u003cth\u003e100 ft\u003c\/th\u003e\n\u003cth\u003e140 ft\u003c\/th\u003e\n\u003cth\u003e180 ft\u003c\/th\u003e\n\u003cth\u003e220 ft\u003c\/th\u003e\n\u003cth\u003e260 ft\u003c\/th\u003e\n\u003cth\u003e300 ft\u003c\/th\u003e\n\u003cth\u003e400 ft\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e40 PSI\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e20.3\u003c\/td\u003e\n\u003ctd\u003e19.1\u003c\/td\u003e\n\u003ctd\u003e17.8\u003c\/td\u003e\n\u003ctd\u003e16.1\u003c\/td\u003e\n\u003ctd\u003e13.9\u003c\/td\u003e\n\u003ctd\u003e5.7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e50 PSI\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e19.6\u003c\/td\u003e\n\u003ctd\u003e18.3\u003c\/td\u003e\n\u003ctd\u003e16.8\u003c\/td\u003e\n\u003ctd\u003e14.9\u003c\/td\u003e\n\u003ctd\u003e12.3\u003c\/td\u003e\n\u003ctd\u003e3.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e60 PSI\u003c\/td\u003e\n\u003ctd\u003e20.1\u003c\/td\u003e\n\u003ctd\u003e18.9\u003c\/td\u003e\n\u003ctd\u003e17.5\u003c\/td\u003e\n\u003ctd\u003e15.8\u003c\/td\u003e\n\u003ctd\u003e13.5\u003c\/td\u003e\n\u003ctd\u003e10.6\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"font-size:12.5px;color:#9B9EA3;margin-top:8px;line-height:1.55\"\u003eGPM by depth to pumping water level, verbatim from the Grundfos 16 gpm easy selection chart for the 16S20-18 (SQ, SQE, SmartFlo and SP data booklet, 60 Hz), at full speed: the most the pump delivers while the CUE 100 holds that pressure; at lower demand the drive slows the pump. Riser and pipe friction are not included. A dash means Grundfos prints no figure: on the shallow side the flow is past the chart range, on the deep side the pump cannot hold that pressure.\u003c\/p\u003e\n\u003cdiv style=\"display:flex;flex-wrap:wrap;gap:10px;margin:22px 0 4px\"\u003e\n\u003ca href=\"\/pages\/submersible-well-pump-sizing-calculator\" style=\"flex:1 1 200px;text-align:center;display:block;background:#B3122A;color:#ffffff;font-family:Arial Black,Arial,sans-serif;font-size:12px;text-transform:uppercase;letter-spacing:1.2px;padding:11px 18px;text-decoration:none\"\u003eSubmersible Calculator\u003c\/a\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eBefore You Buy — The Limits That Decide the Fit\u003c\/div\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eCheck\u003c\/th\u003e\n\u003cth\u003eWhat to confirm\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eWell size\u003c\/td\u003e\n\u003ctd\u003e4 in or larger casing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower\u003c\/td\u003e\n\u003ctd\u003e230 V single-phase supply to the drive; the motor runs only from the drive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWater\u003c\/td\u003e\n\u003ctd\u003eUp to 104°F with at least 0.25 ft\/s flowing past the 4 in motor; drinking water up to 86°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure tank\u003c\/td\u003e\n\u003ctd\u003eA diaphragm tank sized to the CUE 100 instructions, between the well and the first tap\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrive location\u003c\/td\u003e\n\u003ctd\u003eWall-mounted, indoors or outdoors (NEMA 4X); keep within the drop-cable length the CUE 100 instructions allow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSand\u003c\/td\u003e\n\u003ctd\u003eUp to 50 ppm for SP 5S-25S\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eMaterials of Construction\u003c\/div\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003ePart\u003c\/th\u003e\n\u003cth\u003eMaterial\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eImpellers, chambers, strainer, cable guard\u003c\/td\u003e\n\u003ctd\u003eAISI 304 stainless steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePump shaft\u003c\/td\u003e\n\u003ctd\u003eStainless steel, EN 1.4057\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBearings\u003c\/td\u003e\n\u003ctd\u003eNBR elastomer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor\u003c\/td\u003e\n\u003ctd\u003eWater-filled Grundfos MS submersible motor, stainless steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"font-size:12.5px;color:#9B9EA3;margin-top:8px;line-height:1.55\"\u003eSource: Grundfos SP data booklet, standard S construction.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"gs-contact\"\u003eFor engineering-led sizing and selection support or a factory submittal, email \u003ca href=\"mailto:sales@watermainsupply.com\"\u003esales@watermainsupply.com\u003c\/a\u003e or call \u003ca href=\"tel:18885104036\"\u003e1-888.510.4036\u003c\/a\u003e.\u003cbr\u003e© Watermain Supply — A division of E4 Industrial LLC\u003c\/div\u003e\n\n\u003c\/div\u003e\n\u003ch5\u003eData Sheet\u003c\/h5\u003e\u003cdiv class=\"gs\"\u003e\u003cdiv class=\"gs-dl\"\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0264\/1913\/4527\/files\/CUE_100_product_Leaflet_v3_QR.pdf?v=1788919445\" target=\"_blank\" rel=\"noopener\"\u003eCUE 100 Product Leaflet\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0264\/1913\/4527\/files\/93232651_07.2024_CUE_100_online.pdf?v=1788919445\" target=\"_blank\" rel=\"noopener\"\u003eCUE 100 Installation and Operating Instructions\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0264\/1913\/4527\/files\/LSPSL002.pdf?v=1788919444\" target=\"_blank\" rel=\"noopener\"\u003eGrundfos SP Submersible Pumps Data Booklet\u003c\/a\u003e\n\u003c\/div\u003e\u003c\/div\u003e\u003ch5\u003eVideos\u003c\/h5\u003e\u003cdiv class=\"gs\"\u003e\u003cdiv class=\"gs-sec\" style=\"margin-top:6px\"\u003e\u003cdiv style=\"display:grid;grid-template-columns:repeat(auto-fit,minmax(320px,1fr));gap:16px;max-width:900px\"\u003e\n\u003cdiv style=\"position:relative;padding-bottom:56.25%;height:0;overflow:hidden\"\u003e\u003ciframe src=\"https:\/\/www.youtube.com\/embed\/JSZLNfMMIpo\" title=\"Grundfos CUE 100 overview\" style=\"position:absolute;top:0;left:0;width:100%;height:100%;border:0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture\" allowfullscreen\u003e\u003c\/iframe\u003e\u003c\/div\u003e\n\u003cdiv style=\"position:relative;padding-bottom:56.25%;height:0;overflow:hidden\"\u003e\u003ciframe src=\"https:\/\/www.youtube.com\/embed\/s-6jNIZKvAI\" title=\"Grundfos CUE 100 setup demonstration\" style=\"position:absolute;top:0;left:0;width:100%;height:100%;border:0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture\" allowfullscreen\u003e\u003c\/iframe\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/div\u003e\u003c\/div\u003e\u003ch5\u003eUnyConnect App\u003c\/h5\u003e\u003cdiv class=\"gs\"\u003e\u003cdiv class=\"gs-sec\" style=\"margin-top:6px\"\u003e\n\u003cdiv class=\"gs-h\"\u003eSet Up At The Drive Or From Your Phone\u003c\/div\u003e\n\u003cdiv class=\"gs-lead\"\u003e\u003cp\u003eThe CUE 100 is set up at the drive keypad, or over Bluetooth with the free UnyConnect app on an iOS or Android phone. UnyConnect reads status and live operating data, sets the pressure setpoint and control parameters, and shows diagnostic alarms. Remote monitoring away from the wellhead requires the appropriate integration.\u003c\/p\u003e\u003c\/div\u003e\n\u003cdiv style=\"margin-top:16px\"\u003e\n\u003ca href=\"https:\/\/apps.apple.com\/us\/app\/unyconnect\/id6443696303\" target=\"_blank\" rel=\"noopener\" style=\"display:inline-block;background:#B3122A;color:#fff!important;font-family:Arial Black,Arial,sans-serif;font-size:13px;letter-spacing:1px;text-transform:uppercase;text-decoration:none;padding:12px 24px;border-radius:999px;margin:0 10px 10px 0\"\u003eDownload for iOS\u003c\/a\u003e\u003ca href=\"https:\/\/play.google.com\/store\/apps\/details?id=com.nastec.unyconnect\u0026amp;pcampaignid=web_share\" target=\"_blank\" rel=\"noopener\" style=\"display:inline-block;background:#4A4A4F;color:#fff!important;font-family:Arial Black,Arial,sans-serif;font-size:13px;letter-spacing:1px;text-transform:uppercase;text-decoration:none;padding:12px 24px;border-radius:999px;margin:0 10px 10px 0\"\u003eDownload for Android\u003c\/a\u003e\n\u003c\/div\u003e\n\u003cp style=\"font-size:12px;color:#9B9EA3;margin-top:12px\"\u003eUnyConnect is a free app for the CUE 100 drive. Bluetooth must be enabled on the CUE 100 before pairing.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/div\u003e\u003c!-- \/TABS --\u003e","brand":"Grundfos","offers":[{"title":"Default Title","offer_id":47465163096239,"sku":"93336045","price":3937.35,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0264\/1913\/4527\/files\/Grundfox_4_in_CUE_100_Sumbersible_pump_motor_controller_package.webp?v=1788919471"},{"product_id":"grundfos-16s30-24-cue-100-well-pump-package","title":"Grundfos 16S30-24 CUE 100 Constant Pressure Well Pump Package - 3 HP, 533 ft at 16 GPM, 208-230V 1Ph Input - 93336047","description":"\u003c!-- TABS --\u003e\n\u003ch5\u003eDescription\u003c\/h5\u003e\n\u003cdiv class=\"gs\"\u003e\n\n\u003cdiv class=\"gs-head\"\u003e\n\u003cdiv class=\"gs-eyebrow\"\u003eGrundfos · 4 in Constant Pressure Well Pump Package\u003c\/div\u003e\n\u003cdiv class=\"gs-title\"\u003e16S30-24 CUE 100\u003c\/div\u003e\n\u003cdiv class=\"gs-sub\"\u003eConstant-pressure well water package under one Grundfos order number: a 16S30-24 stainless steel SP pump end, a 3 HP 4 in three-phase motor and a CUE 100 30 drive with its pressure transducer. Runs from 208-230 V single-phase service.\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"gs-badges\"\u003e\n\u003cdiv class=\"gs-badge\" style=\"background:#B3122A;color:#FFFFFF;border-color:#B3122A\"\u003e16 GPM Rated Flow\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003e533 ft at 16 GPM\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003e3 HP\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003e208-230V 1Ph In · 3Ph Motor\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003eConstant Pressure · Transducer Included\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003e4 in Min. Well\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003e1-1\/4 in NPT Discharge\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003eNEMA 4X Outdoor Drive\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003e87 lb Ship Weight (Package)\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eOverview\u003c\/div\u003e\n\u003cdiv class=\"gs-lead\"\u003e\n\u003cp\u003eThis package brings together the three Grundfos components of a constant-pressure well system: the 16S30-24 pump end, a 3 HP 4 in three-phase submersible motor and the CUE 100 variable-frequency drive. The drive reads the included pressure transducer and changes pump speed to hold the pressure you set as taps open and close, so the house sees steady pressure instead of a pressure switch's swing.\u003c\/p\u003e\n\u003cp\u003eThe CUE 100 takes 208-230 V single-phase power and makes three-phase power for the motor, so you get a three-phase pump's smooth, soft-started running on ordinary single-phase service. The drive is NEMA 4X \/ IP66 for outdoor mounting and is set up at its keypad or over Bluetooth with the free UnyConnect app.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSteady pressure.\u003c\/strong\u003e The drive holds the setpoint from one tap to full flow and slows the pump when demand drops.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStainless steel SP hydraulics.\u003c\/strong\u003e AISI 304 impellers, chambers and outer parts, a built-in check valve and a sand-handling bearing design.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDiagnostics at the wellhead.\u003c\/strong\u003e Time- and date-stamped alarms and warnings at the drive and in the app; Modbus, BACnet and Bluetooth connectivity.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"background:#FFFFFF;border:1px solid #C7CBD1;border-top:3px solid #B3122A;padding:12px 16px 12px;margin:16px 0 4px;font-size:13.5px;line-height:1.55;color:#4A4A4F\"\u003e\n\u003cdiv style=\"font-family:Arial Black,Arial,sans-serif;font-size:11px;letter-spacing:1.2px;text-transform:uppercase;color:#B3122A;margin-bottom:8px\"\u003eWhat Ships and What It Needs to Run\u003c\/div\u003e\n\u003cp style=\"margin:0 0 6px\"\u003e\u003cstrong style=\"color:#B3122A\"\u003eIncluded, under order number 93336047:\u003c\/strong\u003e the 16S30-24 SP pump end (10010024), a 3 HP 4 in three-phase MS4000 motor (92959950) and the CUE 100 30 drive (92939800) with its pressure transducer. Grundfos lists them as three components of one package.\u003c\/p\u003e\n\u003cp style=\"margin:0 0 6px\"\u003e\u003cstrong style=\"color:#B3122A\"\u003eRequired, ordered separately:\u003c\/strong\u003e a diaphragm pressure tank sized to the CUE 100 instructions, drop pipe, submersible drop cable and splice kit for your setting depth, and a 208-230 V single-phase supply and breaker for the drive.\u003c\/p\u003e\n\u003cp style=\"margin:0 0 6px\"\u003e\u003cstrong style=\"color:#B3122A\"\u003eNever connect the motor straight to the supply.\u003c\/strong\u003e It is a three-phase motor and runs only from the CUE 100.\u003c\/p\u003e\n\u003cp style=\"margin:0\"\u003e\u003cstrong style=\"color:#B3122A\"\u003eReplacement parts:\u003c\/strong\u003e the drive alone is on our \u003ca href=\"\/products\/grundfos-cue-100-constant-pressure-drive\"\u003eGrundfos CUE 100 Constant Pressure Drive\u003c\/a\u003e listing, the motor on our \u003ca href=\"\/products\/grundfos-ms-4-in-submersible-motor\"\u003eGrundfos MS 4 in motor\u003c\/a\u003e listing and the pump end on our \u003ca href=\"\/products\/grundfos-16s-sp-4-in-submersible-pump-end\"\u003eGrundfos 16S SP pump end\u003c\/a\u003e listing.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"background:#E1E3E6;border-left:3px solid #B8BDC4;padding:8px 14px;font-size:11.5px;color:#4A4A4F;margin-top:14px;line-height:1.5\"\u003eGenuine Grundfos equipment, factory-new in original packaging — sold and supported by Watermain Supply, an independent industrial supplier.\u003c\/div\u003e\n\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eWarranty\u003c\/div\u003e\n\u003cdiv class=\"gs-lead\"\u003e\u003cp\u003e24 months from date of installation, but not more than 30 months from date of manufacture. In Grundfos's words, products are “warranted to the original user only to be free of defects in material and workmanship”; the full terms are in the installation and operating instructions on the Data Sheet tab.\u003c\/p\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eSpecifications\u003c\/div\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage order number\u003c\/td\u003e\n\u003ctd\u003e93336047\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePump end\u003c\/td\u003e\n\u003ctd\u003e16S30-24, 16 GPM rated, AISI 304 stainless steel (10010024)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor\u003c\/td\u003e\n\u003ctd\u003e3 HP, 4 in, three-phase MS4000 (92959950)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrive\u003c\/td\u003e\n\u003ctd\u003eCUE 100 30, 12.5 A max motor service-factor current, NEMA 4X \/ IP66 outdoor (92939800)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrive supply\u003c\/td\u003e\n\u003ctd\u003e208-230 V, single phase in; three phase out to the motor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure transducer\u003c\/td\u003e\n\u003ctd\u003eIncluded with the drive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDischarge\u003c\/td\u003e\n\u003ctd\u003e1-1\/4 in NPT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum well\u003c\/td\u003e\n\u003ctd\u003e4 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping weight\u003c\/td\u003e\n\u003ctd\u003e87 lb, complete package\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"font-size:12.5px;color:#9B9EA3;margin-top:8px;line-height:1.55\"\u003eSource: Grundfos US groundwater price list, January 2026 (4 in CUE 100 packages and CUE 100 drives).\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eModels \u0026amp; Performance — Will It Do What You Need?\u003c\/div\u003e\n\u003cp style=\"font-size:13.5px;margin-bottom:10px\"\u003eThe first table reads like the curve: the head the pump adds from shut-off to the end of its curve. The second shows what it delivers while the drive holds 40, 50 or 60 PSI at your pumping water level.\u003c\/p\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003cth\u003eHP\u003c\/th\u003e\n\u003cth\u003e0 GPM (Shut-off)\u003c\/th\u003e\n\u003cth\u003e4.1 GPM\u003c\/th\u003e\n\u003cth\u003e10.3 GPM\u003c\/th\u003e\n\u003cth\u003e16 GPM (Rated)\u003c\/th\u003e\n\u003cth\u003e20.6 GPM (Max)\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e16S30-24\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003ctd\u003e717\u003c\/td\u003e\n\u003ctd\u003e679\u003c\/td\u003e\n\u003ctd\u003e605\u003c\/td\u003e\n\u003ctd\u003e533\u003c\/td\u003e\n\u003ctd\u003e323\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"font-size:12.5px;color:#9B9EA3;margin-top:8px;line-height:1.55\"\u003eTotal head in feet. The shut-off and flow columns are read from the Grundfos 60 Hz curve for the 16S30-24, digitized from the published vector curve in the Grundfos SP 16S data sheet (60 Hz), at the nearest published point and rounded down. The (Rated) column is the nominal head Grundfos prints for the 16S30-24 at 16 GPM, verbatim. 1 ft of head = 0.433 PSI. Full curves are in the product images and on the Data Sheet tab.\u003c\/p\u003e\n\u003cp style=\"font-size:13.5px;margin-bottom:10px;margin-top:18px\"\u003e\u003cstrong\u003eWhat It Delivers at Your Set Pressure\u003c\/strong\u003e (GPM by depth to water)\u003c\/p\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSet pressure\u003c\/th\u003e\n\u003cth\u003e180 ft\u003c\/th\u003e\n\u003cth\u003e220 ft\u003c\/th\u003e\n\u003cth\u003e260 ft\u003c\/th\u003e\n\u003cth\u003e300 ft\u003c\/th\u003e\n\u003cth\u003e340 ft\u003c\/th\u003e\n\u003cth\u003e460 ft\u003c\/th\u003e\n\u003cth\u003e600 ft\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e40 PSI\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e20.2\u003c\/td\u003e\n\u003ctd\u003e19.3\u003c\/td\u003e\n\u003ctd\u003e18.4\u003c\/td\u003e\n\u003ctd\u003e17.3\u003c\/td\u003e\n\u003ctd\u003e12.5\u003c\/td\u003e\n\u003ctd\u003e2.8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e50 PSI\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e19.8\u003c\/td\u003e\n\u003ctd\u003e18.8\u003c\/td\u003e\n\u003ctd\u003e17.8\u003c\/td\u003e\n\u003ctd\u003e16.7\u003c\/td\u003e\n\u003ctd\u003e11.3\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e60 PSI\u003c\/td\u003e\n\u003ctd\u003e20.1\u003c\/td\u003e\n\u003ctd\u003e19.2\u003c\/td\u003e\n\u003ctd\u003e18.3\u003c\/td\u003e\n\u003ctd\u003e17.2\u003c\/td\u003e\n\u003ctd\u003e15.8\u003c\/td\u003e\n\u003ctd\u003e9.8\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"font-size:12.5px;color:#9B9EA3;margin-top:8px;line-height:1.55\"\u003eGPM by depth to pumping water level, verbatim from the Grundfos 16 gpm easy selection chart for the 16S30-24 (SQ, SQE, SmartFlo and SP data booklet, 60 Hz), at full speed: the most the pump delivers while the CUE 100 holds that pressure; at lower demand the drive slows the pump. Riser and pipe friction are not included. A dash means Grundfos prints no figure: on the shallow side the flow is past the chart range, on the deep side the pump cannot hold that pressure.\u003c\/p\u003e\n\u003cdiv style=\"display:flex;flex-wrap:wrap;gap:10px;margin:22px 0 4px\"\u003e\n\u003ca href=\"\/pages\/submersible-well-pump-sizing-calculator\" style=\"flex:1 1 200px;text-align:center;display:block;background:#B3122A;color:#ffffff;font-family:Arial Black,Arial,sans-serif;font-size:12px;text-transform:uppercase;letter-spacing:1.2px;padding:11px 18px;text-decoration:none\"\u003eSubmersible Calculator\u003c\/a\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eBefore You Buy — The Limits That Decide the Fit\u003c\/div\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eCheck\u003c\/th\u003e\n\u003cth\u003eWhat to confirm\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eWell size\u003c\/td\u003e\n\u003ctd\u003e4 in or larger casing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower\u003c\/td\u003e\n\u003ctd\u003e208-230 V single-phase supply to the drive; the motor runs only from the drive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWater\u003c\/td\u003e\n\u003ctd\u003eUp to 104°F with at least 0.25 ft\/s flowing past the 4 in motor; drinking water up to 86°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure tank\u003c\/td\u003e\n\u003ctd\u003eA diaphragm tank sized to the CUE 100 instructions, between the well and the first tap\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrive location\u003c\/td\u003e\n\u003ctd\u003eWall-mounted, indoors or outdoors (NEMA 4X); keep within the drop-cable length the CUE 100 instructions allow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSand\u003c\/td\u003e\n\u003ctd\u003eUp to 50 ppm for SP 5S-25S\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eMaterials of Construction\u003c\/div\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003ePart\u003c\/th\u003e\n\u003cth\u003eMaterial\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eImpellers, chambers, strainer, cable guard\u003c\/td\u003e\n\u003ctd\u003eAISI 304 stainless steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePump shaft\u003c\/td\u003e\n\u003ctd\u003eStainless steel, EN 1.4057\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBearings\u003c\/td\u003e\n\u003ctd\u003eNBR elastomer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor\u003c\/td\u003e\n\u003ctd\u003eWater-filled Grundfos MS submersible motor, stainless steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"font-size:12.5px;color:#9B9EA3;margin-top:8px;line-height:1.55\"\u003eSource: Grundfos SP data booklet, standard S construction.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"gs-contact\"\u003eFor engineering-led sizing and selection support or a factory submittal, email \u003ca href=\"mailto:sales@watermainsupply.com\"\u003esales@watermainsupply.com\u003c\/a\u003e or call \u003ca href=\"tel:18885104036\"\u003e1-888.510.4036\u003c\/a\u003e.\u003cbr\u003e© Watermain Supply — A division of E4 Industrial LLC\u003c\/div\u003e\n\n\u003c\/div\u003e\n\u003ch5\u003eData Sheet\u003c\/h5\u003e\u003cdiv class=\"gs\"\u003e\u003cdiv class=\"gs-dl\"\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0264\/1913\/4527\/files\/CUE_100_product_Leaflet_v3_QR.pdf?v=1788919445\" target=\"_blank\" rel=\"noopener\"\u003eCUE 100 Product Leaflet\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0264\/1913\/4527\/files\/93232651_07.2024_CUE_100_online.pdf?v=1788919445\" target=\"_blank\" rel=\"noopener\"\u003eCUE 100 Installation and Operating Instructions\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0264\/1913\/4527\/files\/LSPSL002.pdf?v=1788919444\" target=\"_blank\" rel=\"noopener\"\u003eGrundfos SP Submersible Pumps Data Booklet\u003c\/a\u003e\n\u003c\/div\u003e\u003c\/div\u003e\u003ch5\u003eVideos\u003c\/h5\u003e\u003cdiv class=\"gs\"\u003e\u003cdiv class=\"gs-sec\" style=\"margin-top:6px\"\u003e\u003cdiv style=\"display:grid;grid-template-columns:repeat(auto-fit,minmax(320px,1fr));gap:16px;max-width:900px\"\u003e\n\u003cdiv style=\"position:relative;padding-bottom:56.25%;height:0;overflow:hidden\"\u003e\u003ciframe src=\"https:\/\/www.youtube.com\/embed\/JSZLNfMMIpo\" title=\"Grundfos CUE 100 overview\" style=\"position:absolute;top:0;left:0;width:100%;height:100%;border:0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture\" allowfullscreen\u003e\u003c\/iframe\u003e\u003c\/div\u003e\n\u003cdiv style=\"position:relative;padding-bottom:56.25%;height:0;overflow:hidden\"\u003e\u003ciframe src=\"https:\/\/www.youtube.com\/embed\/s-6jNIZKvAI\" title=\"Grundfos CUE 100 setup demonstration\" style=\"position:absolute;top:0;left:0;width:100%;height:100%;border:0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture\" allowfullscreen\u003e\u003c\/iframe\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/div\u003e\u003c\/div\u003e\u003ch5\u003eUnyConnect App\u003c\/h5\u003e\u003cdiv class=\"gs\"\u003e\u003cdiv class=\"gs-sec\" style=\"margin-top:6px\"\u003e\n\u003cdiv class=\"gs-h\"\u003eSet Up At The Drive Or From Your Phone\u003c\/div\u003e\n\u003cdiv class=\"gs-lead\"\u003e\u003cp\u003eThe CUE 100 is set up at the drive keypad, or over Bluetooth with the free UnyConnect app on an iOS or Android phone. UnyConnect reads status and live operating data, sets the pressure setpoint and control parameters, and shows diagnostic alarms. Remote monitoring away from the wellhead requires the appropriate integration.\u003c\/p\u003e\u003c\/div\u003e\n\u003cdiv style=\"margin-top:16px\"\u003e\n\u003ca href=\"https:\/\/apps.apple.com\/us\/app\/unyconnect\/id6443696303\" target=\"_blank\" rel=\"noopener\" style=\"display:inline-block;background:#B3122A;color:#fff!important;font-family:Arial Black,Arial,sans-serif;font-size:13px;letter-spacing:1px;text-transform:uppercase;text-decoration:none;padding:12px 24px;border-radius:999px;margin:0 10px 10px 0\"\u003eDownload for iOS\u003c\/a\u003e\u003ca href=\"https:\/\/play.google.com\/store\/apps\/details?id=com.nastec.unyconnect\u0026amp;pcampaignid=web_share\" target=\"_blank\" rel=\"noopener\" style=\"display:inline-block;background:#4A4A4F;color:#fff!important;font-family:Arial Black,Arial,sans-serif;font-size:13px;letter-spacing:1px;text-transform:uppercase;text-decoration:none;padding:12px 24px;border-radius:999px;margin:0 10px 10px 0\"\u003eDownload for Android\u003c\/a\u003e\n\u003c\/div\u003e\n\u003cp style=\"font-size:12px;color:#9B9EA3;margin-top:12px\"\u003eUnyConnect is a free app for the CUE 100 drive. Bluetooth must be enabled on the CUE 100 before pairing.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/div\u003e\u003c!-- \/TABS --\u003e","brand":"Grundfos","offers":[{"title":"Default Title","offer_id":47465163129007,"sku":"93336047","price":5326.67,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0264\/1913\/4527\/files\/Grundfox_4_in_CUE_100_Sumbersible_pump_motor_controller_package.webp?v=1788919471"},{"product_id":"grundfos-25s10-7-cue-100-well-pump-package","title":"Grundfos 25S10-7 CUE 100 Constant Pressure Well Pump Package - 1 HP, 146 ft at 25 GPM, 230V 1Ph Input - 93336048","description":"\u003c!-- TABS --\u003e\n\u003ch5\u003eDescription\u003c\/h5\u003e\n\u003cdiv class=\"gs\"\u003e\n\n\u003cdiv class=\"gs-head\"\u003e\n\u003cdiv class=\"gs-eyebrow\"\u003eGrundfos · 4 in Constant Pressure Well Pump Package\u003c\/div\u003e\n\u003cdiv class=\"gs-title\"\u003e25S10-7 CUE 100\u003c\/div\u003e\n\u003cdiv class=\"gs-sub\"\u003eConstant-pressure well water package under one Grundfos order number: a 25S10-7 stainless steel SP pump end, a 1 HP 4 in three-phase motor and a CUE 100 10 drive with its pressure transducer. Runs from 230 V single-phase service.\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"gs-badges\"\u003e\n\u003cdiv class=\"gs-badge\" style=\"background:#B3122A;color:#FFFFFF;border-color:#B3122A\"\u003e25 GPM Rated Flow\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003e146 ft at 25 GPM\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003e1 HP\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003e230V 1Ph In · 3Ph Motor\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003eConstant Pressure · Transducer Included\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003e4 in Min. Well\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003e1-1\/2 in NPT Discharge\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003eNEMA 4X Outdoor Drive\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003e54 lb Ship Weight (Package)\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eOverview\u003c\/div\u003e\n\u003cdiv class=\"gs-lead\"\u003e\n\u003cp\u003eThis package brings together the three Grundfos components of a constant-pressure well system: the 25S10-7 pump end, a 1 HP 4 in three-phase submersible motor and the CUE 100 variable-frequency drive. The drive reads the included pressure transducer and changes pump speed to hold the pressure you set as taps open and close, so the house sees steady pressure instead of a pressure switch's swing.\u003c\/p\u003e\n\u003cp\u003eThe CUE 100 takes 230 V single-phase power and makes three-phase power for the motor, so you get a three-phase pump's smooth, soft-started running on ordinary single-phase service. The drive is NEMA 4X \/ IP66 for outdoor mounting and is set up at its keypad or over Bluetooth with the free UnyConnect app.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSteady pressure.\u003c\/strong\u003e The drive holds the setpoint from one tap to full flow and slows the pump when demand drops.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStainless steel SP hydraulics.\u003c\/strong\u003e AISI 304 impellers, chambers and outer parts, a built-in check valve and a sand-handling bearing design.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDiagnostics at the wellhead.\u003c\/strong\u003e Time- and date-stamped alarms and warnings at the drive and in the app; Modbus, BACnet and Bluetooth connectivity.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"background:#FFFFFF;border:1px solid #C7CBD1;border-top:3px solid #B3122A;padding:12px 16px 12px;margin:16px 0 4px;font-size:13.5px;line-height:1.55;color:#4A4A4F\"\u003e\n\u003cdiv style=\"font-family:Arial Black,Arial,sans-serif;font-size:11px;letter-spacing:1.2px;text-transform:uppercase;color:#B3122A;margin-bottom:8px\"\u003eWhat Ships and What It Needs to Run\u003c\/div\u003e\n\u003cp style=\"margin:0 0 6px\"\u003e\u003cstrong style=\"color:#B3122A\"\u003eIncluded, under order number 93336048:\u003c\/strong\u003e the 25S10-7 SP pump end (5010007), a 1 HP 4 in three-phase MS402 motor (96465627) and the CUE 100 10 drive (93281860) with its pressure transducer. Grundfos lists them as three components of one package.\u003c\/p\u003e\n\u003cp style=\"margin:0 0 6px\"\u003e\u003cstrong style=\"color:#B3122A\"\u003eRequired, ordered separately:\u003c\/strong\u003e a diaphragm pressure tank sized to the CUE 100 instructions, drop pipe, submersible drop cable and splice kit for your setting depth, and a 230 V single-phase supply and breaker for the drive.\u003c\/p\u003e\n\u003cp style=\"margin:0 0 6px\"\u003e\u003cstrong style=\"color:#B3122A\"\u003eNever connect the motor straight to the supply.\u003c\/strong\u003e It is a three-phase motor and runs only from the CUE 100.\u003c\/p\u003e\n\u003cp style=\"margin:0\"\u003e\u003cstrong style=\"color:#B3122A\"\u003eReplacement parts:\u003c\/strong\u003e the drive alone is on our \u003ca href=\"\/products\/grundfos-cue-100-constant-pressure-drive\"\u003eGrundfos CUE 100 Constant Pressure Drive\u003c\/a\u003e listing, the motor on our \u003ca href=\"\/products\/grundfos-ms-4-in-submersible-motor\"\u003eGrundfos MS 4 in motor\u003c\/a\u003e listing and the pump end on our \u003ca href=\"\/products\/grundfos-25s-sp-4-in-submersible-pump-end\"\u003eGrundfos 25S SP pump end\u003c\/a\u003e listing.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"background:#E1E3E6;border-left:3px solid #B8BDC4;padding:8px 14px;font-size:11.5px;color:#4A4A4F;margin-top:14px;line-height:1.5\"\u003eGenuine Grundfos equipment, factory-new in original packaging — sold and supported by Watermain Supply, an independent industrial supplier.\u003c\/div\u003e\n\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eWarranty\u003c\/div\u003e\n\u003cdiv class=\"gs-lead\"\u003e\u003cp\u003e24 months from date of installation, but not more than 30 months from date of manufacture. In Grundfos's words, products are “warranted to the original user only to be free of defects in material and workmanship”; the full terms are in the installation and operating instructions on the Data Sheet tab.\u003c\/p\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eSpecifications\u003c\/div\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage order number\u003c\/td\u003e\n\u003ctd\u003e93336048\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePump end\u003c\/td\u003e\n\u003ctd\u003e25S10-7, 25 GPM rated, AISI 304 stainless steel (5010007)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor\u003c\/td\u003e\n\u003ctd\u003e1 HP, 4 in, three-phase MS402 (96465627)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrive\u003c\/td\u003e\n\u003ctd\u003eCUE 100 10, 6 A max motor service-factor current, NEMA 4X \/ IP66 outdoor (93281860)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrive supply\u003c\/td\u003e\n\u003ctd\u003e230 V, single phase in; three phase out to the motor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure transducer\u003c\/td\u003e\n\u003ctd\u003eIncluded with the drive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDischarge\u003c\/td\u003e\n\u003ctd\u003e1-1\/2 in NPT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum well\u003c\/td\u003e\n\u003ctd\u003e4 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping weight\u003c\/td\u003e\n\u003ctd\u003e54 lb, complete package\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"font-size:12.5px;color:#9B9EA3;margin-top:8px;line-height:1.55\"\u003eSource: Grundfos US groundwater price list, January 2026 (4 in CUE 100 packages and CUE 100 drives).\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eModels \u0026amp; Performance — Will It Do What You Need?\u003c\/div\u003e\n\u003cp style=\"font-size:13.5px;margin-bottom:10px\"\u003eThe first table reads like the curve: the head the pump adds from shut-off to the end of its curve. The second shows what it delivers while the drive holds 40, 50 or 60 PSI at your pumping water level.\u003c\/p\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003cth\u003eHP\u003c\/th\u003e\n\u003cth\u003e0 GPM (Shut-off)\u003c\/th\u003e\n\u003cth\u003e6.9 GPM\u003c\/th\u003e\n\u003cth\u003e17.1 GPM\u003c\/th\u003e\n\u003cth\u003e25 GPM (Rated)\u003c\/th\u003e\n\u003cth\u003e34.3 GPM (Max)\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e25S10-7\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003ctd\u003e212\u003c\/td\u003e\n\u003ctd\u003e193\u003c\/td\u003e\n\u003ctd\u003e170\u003c\/td\u003e\n\u003ctd\u003e146\u003c\/td\u003e\n\u003ctd\u003e75\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"font-size:12.5px;color:#9B9EA3;margin-top:8px;line-height:1.55\"\u003eTotal head in feet. The shut-off and flow columns are read from the Grundfos 60 Hz curve for the 25S10-7, digitized from the published vector curve in the Grundfos SP 25S data sheet (60 Hz), at the nearest published point and rounded down. The (Rated) column is the nominal head Grundfos prints for the 25S10-7 at 25 GPM, verbatim. 1 ft of head = 0.433 PSI. Full curves are in the product images and on the Data Sheet tab.\u003c\/p\u003e\n\u003cp style=\"font-size:13.5px;margin-bottom:10px;margin-top:18px\"\u003e\u003cstrong\u003eWhat It Delivers at Your Set Pressure\u003c\/strong\u003e (GPM by depth to water)\u003c\/p\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSet pressure\u003c\/th\u003e\n\u003cth\u003e20 ft\u003c\/th\u003e\n\u003cth\u003e40 ft\u003c\/th\u003e\n\u003cth\u003e60 ft\u003c\/th\u003e\n\u003cth\u003e80 ft\u003c\/th\u003e\n\u003cth\u003e100 ft\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e40 PSI\u003c\/td\u003e\n\u003ctd\u003e29.4\u003c\/td\u003e\n\u003ctd\u003e26.6\u003c\/td\u003e\n\u003ctd\u003e21.3\u003c\/td\u003e\n\u003ctd\u003e16.2\u003c\/td\u003e\n\u003ctd\u003e8.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e50 PSI\u003c\/td\u003e\n\u003ctd\u003e25.3\u003c\/td\u003e\n\u003ctd\u003e21.5\u003c\/td\u003e\n\u003ctd\u003e14.3\u003c\/td\u003e\n\u003ctd\u003e7\u003c\/td\u003e\n\u003ctd\u003e3.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e60 PSI\u003c\/td\u003e\n\u003ctd\u003e19.7\u003c\/td\u003e\n\u003ctd\u003e13.9\u003c\/td\u003e\n\u003ctd\u003e7\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"font-size:12.5px;color:#9B9EA3;margin-top:8px;line-height:1.55\"\u003eGPM by depth to pumping water level, verbatim from the Grundfos 25 gpm easy selection chart for the 25S10-7 (SQ, SQE, SmartFlo and SP data booklet, 60 Hz), at full speed: the most the pump delivers while the CUE 100 holds that pressure; at lower demand the drive slows the pump. Riser and pipe friction are not included. A dash means Grundfos prints no figure: on the shallow side the flow is past the chart range, on the deep side the pump cannot hold that pressure.\u003c\/p\u003e\n\u003cdiv style=\"display:flex;flex-wrap:wrap;gap:10px;margin:22px 0 4px\"\u003e\n\u003ca href=\"\/pages\/submersible-well-pump-sizing-calculator\" style=\"flex:1 1 200px;text-align:center;display:block;background:#B3122A;color:#ffffff;font-family:Arial Black,Arial,sans-serif;font-size:12px;text-transform:uppercase;letter-spacing:1.2px;padding:11px 18px;text-decoration:none\"\u003eSubmersible Calculator\u003c\/a\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eBefore You Buy — The Limits That Decide the Fit\u003c\/div\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eCheck\u003c\/th\u003e\n\u003cth\u003eWhat to confirm\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eWell size\u003c\/td\u003e\n\u003ctd\u003e4 in or larger casing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower\u003c\/td\u003e\n\u003ctd\u003e230 V single-phase supply to the drive; the motor runs only from the drive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWater\u003c\/td\u003e\n\u003ctd\u003eUp to 104°F with at least 0.25 ft\/s flowing past the 4 in motor; drinking water up to 86°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure tank\u003c\/td\u003e\n\u003ctd\u003eA diaphragm tank sized to the CUE 100 instructions, between the well and the first tap\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrive location\u003c\/td\u003e\n\u003ctd\u003eWall-mounted, indoors or outdoors (NEMA 4X); keep within the drop-cable length the CUE 100 instructions allow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSand\u003c\/td\u003e\n\u003ctd\u003eUp to 50 ppm for SP 5S-25S\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eMaterials of Construction\u003c\/div\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003ePart\u003c\/th\u003e\n\u003cth\u003eMaterial\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eImpellers, chambers, strainer, cable guard\u003c\/td\u003e\n\u003ctd\u003eAISI 304 stainless steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePump shaft\u003c\/td\u003e\n\u003ctd\u003eStainless steel, EN 1.4057\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBearings\u003c\/td\u003e\n\u003ctd\u003eNBR elastomer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor\u003c\/td\u003e\n\u003ctd\u003eWater-filled Grundfos MS submersible motor, stainless steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"font-size:12.5px;color:#9B9EA3;margin-top:8px;line-height:1.55\"\u003eSource: Grundfos SP data booklet, standard S construction.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"gs-contact\"\u003eFor engineering-led sizing and selection support or a factory submittal, email \u003ca href=\"mailto:sales@watermainsupply.com\"\u003esales@watermainsupply.com\u003c\/a\u003e or call \u003ca href=\"tel:18885104036\"\u003e1-888.510.4036\u003c\/a\u003e.\u003cbr\u003e© Watermain Supply — A division of E4 Industrial LLC\u003c\/div\u003e\n\n\u003c\/div\u003e\n\u003ch5\u003eData Sheet\u003c\/h5\u003e\u003cdiv class=\"gs\"\u003e\u003cdiv class=\"gs-dl\"\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0264\/1913\/4527\/files\/CUE_100_product_Leaflet_v3_QR.pdf?v=1788919445\" target=\"_blank\" rel=\"noopener\"\u003eCUE 100 Product Leaflet\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0264\/1913\/4527\/files\/93232651_07.2024_CUE_100_online.pdf?v=1788919445\" target=\"_blank\" rel=\"noopener\"\u003eCUE 100 Installation and Operating Instructions\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0264\/1913\/4527\/files\/LSPSL002.pdf?v=1788919444\" target=\"_blank\" rel=\"noopener\"\u003eGrundfos SP Submersible Pumps Data Booklet\u003c\/a\u003e\n\u003c\/div\u003e\u003c\/div\u003e\u003ch5\u003eVideos\u003c\/h5\u003e\u003cdiv class=\"gs\"\u003e\u003cdiv class=\"gs-sec\" style=\"margin-top:6px\"\u003e\u003cdiv style=\"display:grid;grid-template-columns:repeat(auto-fit,minmax(320px,1fr));gap:16px;max-width:900px\"\u003e\n\u003cdiv style=\"position:relative;padding-bottom:56.25%;height:0;overflow:hidden\"\u003e\u003ciframe src=\"https:\/\/www.youtube.com\/embed\/JSZLNfMMIpo\" title=\"Grundfos CUE 100 overview\" style=\"position:absolute;top:0;left:0;width:100%;height:100%;border:0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture\" allowfullscreen\u003e\u003c\/iframe\u003e\u003c\/div\u003e\n\u003cdiv style=\"position:relative;padding-bottom:56.25%;height:0;overflow:hidden\"\u003e\u003ciframe src=\"https:\/\/www.youtube.com\/embed\/s-6jNIZKvAI\" title=\"Grundfos CUE 100 setup demonstration\" style=\"position:absolute;top:0;left:0;width:100%;height:100%;border:0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture\" allowfullscreen\u003e\u003c\/iframe\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/div\u003e\u003c\/div\u003e\u003ch5\u003eUnyConnect App\u003c\/h5\u003e\u003cdiv class=\"gs\"\u003e\u003cdiv class=\"gs-sec\" style=\"margin-top:6px\"\u003e\n\u003cdiv class=\"gs-h\"\u003eSet Up At The Drive Or From Your Phone\u003c\/div\u003e\n\u003cdiv class=\"gs-lead\"\u003e\u003cp\u003eThe CUE 100 is set up at the drive keypad, or over Bluetooth with the free UnyConnect app on an iOS or Android phone. UnyConnect reads status and live operating data, sets the pressure setpoint and control parameters, and shows diagnostic alarms. Remote monitoring away from the wellhead requires the appropriate integration.\u003c\/p\u003e\u003c\/div\u003e\n\u003cdiv style=\"margin-top:16px\"\u003e\n\u003ca href=\"https:\/\/apps.apple.com\/us\/app\/unyconnect\/id6443696303\" target=\"_blank\" rel=\"noopener\" style=\"display:inline-block;background:#B3122A;color:#fff!important;font-family:Arial Black,Arial,sans-serif;font-size:13px;letter-spacing:1px;text-transform:uppercase;text-decoration:none;padding:12px 24px;border-radius:999px;margin:0 10px 10px 0\"\u003eDownload for iOS\u003c\/a\u003e\u003ca href=\"https:\/\/play.google.com\/store\/apps\/details?id=com.nastec.unyconnect\u0026amp;pcampaignid=web_share\" target=\"_blank\" rel=\"noopener\" style=\"display:inline-block;background:#4A4A4F;color:#fff!important;font-family:Arial Black,Arial,sans-serif;font-size:13px;letter-spacing:1px;text-transform:uppercase;text-decoration:none;padding:12px 24px;border-radius:999px;margin:0 10px 10px 0\"\u003eDownload for Android\u003c\/a\u003e\n\u003c\/div\u003e\n\u003cp style=\"font-size:12px;color:#9B9EA3;margin-top:12px\"\u003eUnyConnect is a free app for the CUE 100 drive. Bluetooth must be enabled on the CUE 100 before pairing.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/div\u003e\u003c!-- \/TABS --\u003e","brand":"Grundfos","offers":[{"title":"Default Title","offer_id":47465163161775,"sku":"93336048","price":3157.15,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0264\/1913\/4527\/files\/Grundfox_4_in_CUE_100_Sumbersible_pump_motor_controller_package.webp?v=1788919471"},{"product_id":"grundfos-25s15-9-cue-100-well-pump-package","title":"Grundfos 25S15-9 CUE 100 Constant Pressure Well Pump Package - 1-1\/2 HP, 189 ft at 25 GPM, 230V 1Ph Input - 93336051","description":"\u003c!-- TABS --\u003e\n\u003ch5\u003eDescription\u003c\/h5\u003e\n\u003cdiv class=\"gs\"\u003e\n\n\u003cdiv class=\"gs-head\"\u003e\n\u003cdiv class=\"gs-eyebrow\"\u003eGrundfos · 4 in Constant Pressure Well Pump Package\u003c\/div\u003e\n\u003cdiv class=\"gs-title\"\u003e25S15-9 CUE 100\u003c\/div\u003e\n\u003cdiv class=\"gs-sub\"\u003eConstant-pressure well water package under one Grundfos order number: a 25S15-9 stainless steel SP pump end, a 1-1\/2 HP 4 in three-phase motor and a CUE 100 20 drive with its pressure transducer. Runs from 230 V single-phase service.\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"gs-badges\"\u003e\n\u003cdiv class=\"gs-badge\" style=\"background:#B3122A;color:#FFFFFF;border-color:#B3122A\"\u003e25 GPM Rated Flow\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003e189 ft at 25 GPM\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003e1-1\/2 HP\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003e230V 1Ph In · 3Ph Motor\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003eConstant Pressure · Transducer Included\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003e4 in Min. Well\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003e1-1\/2 in NPT Discharge\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003eNEMA 4X Outdoor Drive\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003e59 lb Ship Weight (Package)\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eOverview\u003c\/div\u003e\n\u003cdiv class=\"gs-lead\"\u003e\n\u003cp\u003eThis package brings together the three Grundfos components of a constant-pressure well system: the 25S15-9 pump end, a 1-1\/2 HP 4 in three-phase submersible motor and the CUE 100 variable-frequency drive. The drive reads the included pressure transducer and changes pump speed to hold the pressure you set as taps open and close, so the house sees steady pressure instead of a pressure switch's swing.\u003c\/p\u003e\n\u003cp\u003eThe CUE 100 takes 230 V single-phase power and makes three-phase power for the motor, so you get a three-phase pump's smooth, soft-started running on ordinary single-phase service. The drive is NEMA 4X \/ IP66 for outdoor mounting and is set up at its keypad or over Bluetooth with the free UnyConnect app.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSteady pressure.\u003c\/strong\u003e The drive holds the setpoint from one tap to full flow and slows the pump when demand drops.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStainless steel SP hydraulics.\u003c\/strong\u003e AISI 304 impellers, chambers and outer parts, a built-in check valve and a sand-handling bearing design.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDiagnostics at the wellhead.\u003c\/strong\u003e Time- and date-stamped alarms and warnings at the drive and in the app; Modbus, BACnet and Bluetooth connectivity.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"background:#FFFFFF;border:1px solid #C7CBD1;border-top:3px solid #B3122A;padding:12px 16px 12px;margin:16px 0 4px;font-size:13.5px;line-height:1.55;color:#4A4A4F\"\u003e\n\u003cdiv style=\"font-family:Arial Black,Arial,sans-serif;font-size:11px;letter-spacing:1.2px;text-transform:uppercase;color:#B3122A;margin-bottom:8px\"\u003eWhat Ships and What It Needs to Run\u003c\/div\u003e\n\u003cp style=\"margin:0 0 6px\"\u003e\u003cstrong style=\"color:#B3122A\"\u003eIncluded, under order number 93336051:\u003c\/strong\u003e the 25S15-9 SP pump end (5010009), a 1-1\/2 HP 4 in three-phase MS402 motor (96465629) and the CUE 100 20 drive (92939786) with its pressure transducer. Grundfos lists them as three components of one package.\u003c\/p\u003e\n\u003cp style=\"margin:0 0 6px\"\u003e\u003cstrong style=\"color:#B3122A\"\u003eRequired, ordered separately:\u003c\/strong\u003e a diaphragm pressure tank sized to the CUE 100 instructions, drop pipe, submersible drop cable and splice kit for your setting depth, and a 230 V single-phase supply and breaker for the drive.\u003c\/p\u003e\n\u003cp style=\"margin:0 0 6px\"\u003e\u003cstrong style=\"color:#B3122A\"\u003eNever connect the motor straight to the supply.\u003c\/strong\u003e It is a three-phase motor and runs only from the CUE 100.\u003c\/p\u003e\n\u003cp style=\"margin:0\"\u003e\u003cstrong style=\"color:#B3122A\"\u003eReplacement parts:\u003c\/strong\u003e the drive alone is on our \u003ca href=\"\/products\/grundfos-cue-100-constant-pressure-drive\"\u003eGrundfos CUE 100 Constant Pressure Drive\u003c\/a\u003e listing, the motor on our \u003ca href=\"\/products\/grundfos-ms-4-in-submersible-motor\"\u003eGrundfos MS 4 in motor\u003c\/a\u003e listing and the pump end on our \u003ca href=\"\/products\/grundfos-25s-sp-4-in-submersible-pump-end\"\u003eGrundfos 25S SP pump end\u003c\/a\u003e listing.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"background:#E1E3E6;border-left:3px solid #B8BDC4;padding:8px 14px;font-size:11.5px;color:#4A4A4F;margin-top:14px;line-height:1.5\"\u003eGenuine Grundfos equipment, factory-new in original packaging — sold and supported by Watermain Supply, an independent industrial supplier.\u003c\/div\u003e\n\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eWarranty\u003c\/div\u003e\n\u003cdiv class=\"gs-lead\"\u003e\u003cp\u003e24 months from date of installation, but not more than 30 months from date of manufacture. In Grundfos's words, products are “warranted to the original user only to be free of defects in material and workmanship”; the full terms are in the installation and operating instructions on the Data Sheet tab.\u003c\/p\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eSpecifications\u003c\/div\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage order number\u003c\/td\u003e\n\u003ctd\u003e93336051\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePump end\u003c\/td\u003e\n\u003ctd\u003e25S15-9, 25 GPM rated, AISI 304 stainless steel (5010009)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor\u003c\/td\u003e\n\u003ctd\u003e1-1\/2 HP, 4 in, three-phase MS402 (96465629)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrive\u003c\/td\u003e\n\u003ctd\u003eCUE 100 20, 9.5 A max motor service-factor current, NEMA 4X \/ IP66 outdoor (92939786)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrive supply\u003c\/td\u003e\n\u003ctd\u003e230 V, single phase in; three phase out to the motor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure transducer\u003c\/td\u003e\n\u003ctd\u003eIncluded with the drive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDischarge\u003c\/td\u003e\n\u003ctd\u003e1-1\/2 in NPT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum well\u003c\/td\u003e\n\u003ctd\u003e4 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping weight\u003c\/td\u003e\n\u003ctd\u003e59 lb, complete package\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"font-size:12.5px;color:#9B9EA3;margin-top:8px;line-height:1.55\"\u003eSource: Grundfos US groundwater price list, January 2026 (4 in CUE 100 packages and CUE 100 drives).\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eModels \u0026amp; Performance — Will It Do What You Need?\u003c\/div\u003e\n\u003cp style=\"font-size:13.5px;margin-bottom:10px\"\u003eThe first table reads like the curve: the head the pump adds from shut-off to the end of its curve. The second shows what it delivers while the drive holds 40, 50 or 60 PSI at your pumping water level.\u003c\/p\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003cth\u003eHP\u003c\/th\u003e\n\u003cth\u003e0 GPM (Shut-off)\u003c\/th\u003e\n\u003cth\u003e6.9 GPM\u003c\/th\u003e\n\u003cth\u003e17.1 GPM\u003c\/th\u003e\n\u003cth\u003e25 GPM (Rated)\u003c\/th\u003e\n\u003cth\u003e34.3 GPM (Max)\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e25S15-9\u003c\/td\u003e\n\u003ctd\u003e1-1\/2\u003c\/td\u003e\n\u003ctd\u003e273\u003c\/td\u003e\n\u003ctd\u003e249\u003c\/td\u003e\n\u003ctd\u003e221\u003c\/td\u003e\n\u003ctd\u003e189\u003c\/td\u003e\n\u003ctd\u003e99\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"font-size:12.5px;color:#9B9EA3;margin-top:8px;line-height:1.55\"\u003eTotal head in feet. The shut-off and flow columns are read from the Grundfos 60 Hz curve for the 25S15-9, digitized from the published vector curve in the Grundfos SP 25S data sheet (60 Hz), at the nearest published point and rounded down. The (Rated) column is the nominal head Grundfos prints for the 25S15-9 at 25 GPM, verbatim. 1 ft of head = 0.433 PSI. Full curves are in the product images and on the Data Sheet tab.\u003c\/p\u003e\n\u003cp style=\"font-size:13.5px;margin-bottom:10px;margin-top:18px\"\u003e\u003cstrong\u003eWhat It Delivers at Your Set Pressure\u003c\/strong\u003e (GPM by depth to water)\u003c\/p\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSet pressure\u003c\/th\u003e\n\u003cth\u003e20 ft\u003c\/th\u003e\n\u003cth\u003e40 ft\u003c\/th\u003e\n\u003cth\u003e80 ft\u003c\/th\u003e\n\u003cth\u003e100 ft\u003c\/th\u003e\n\u003cth\u003e120 ft\u003c\/th\u003e\n\u003cth\u003e160 ft\u003c\/th\u003e\n\u003cth\u003e180 ft\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e40 PSI\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e30.8\u003c\/td\u003e\n\u003ctd\u003e26.3\u003c\/td\u003e\n\u003ctd\u003e22.6\u003c\/td\u003e\n\u003ctd\u003e18.8\u003c\/td\u003e\n\u003ctd\u003e6.8\u003c\/td\u003e\n\u003ctd\u003e3.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e50 PSI\u003c\/td\u003e\n\u003ctd\u003e30.6\u003c\/td\u003e\n\u003ctd\u003e28.4\u003c\/td\u003e\n\u003ctd\u003e22.5\u003c\/td\u003e\n\u003ctd\u003e17.4\u003c\/td\u003e\n\u003ctd\u003e12.3\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e60 PSI\u003c\/td\u003e\n\u003ctd\u003e27.8\u003c\/td\u003e\n\u003ctd\u003e25.5\u003c\/td\u003e\n\u003ctd\u003e17.2\u003c\/td\u003e\n\u003ctd\u003e11\u003c\/td\u003e\n\u003ctd\u003e4.8\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"font-size:12.5px;color:#9B9EA3;margin-top:8px;line-height:1.55\"\u003eGPM by depth to pumping water level, verbatim from the Grundfos 25 gpm easy selection chart for the 25S15-9 (SQ, SQE, SmartFlo and SP data booklet, 60 Hz), at full speed: the most the pump delivers while the CUE 100 holds that pressure; at lower demand the drive slows the pump. Riser and pipe friction are not included. A dash means Grundfos prints no figure: on the shallow side the flow is past the chart range, on the deep side the pump cannot hold that pressure.\u003c\/p\u003e\n\u003cdiv style=\"display:flex;flex-wrap:wrap;gap:10px;margin:22px 0 4px\"\u003e\n\u003ca href=\"\/pages\/submersible-well-pump-sizing-calculator\" style=\"flex:1 1 200px;text-align:center;display:block;background:#B3122A;color:#ffffff;font-family:Arial Black,Arial,sans-serif;font-size:12px;text-transform:uppercase;letter-spacing:1.2px;padding:11px 18px;text-decoration:none\"\u003eSubmersible Calculator\u003c\/a\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eBefore You Buy — The Limits That Decide the Fit\u003c\/div\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eCheck\u003c\/th\u003e\n\u003cth\u003eWhat to confirm\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eWell size\u003c\/td\u003e\n\u003ctd\u003e4 in or larger casing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower\u003c\/td\u003e\n\u003ctd\u003e230 V single-phase supply to the drive; the motor runs only from the drive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWater\u003c\/td\u003e\n\u003ctd\u003eUp to 104°F with at least 0.25 ft\/s flowing past the 4 in motor; drinking water up to 86°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure tank\u003c\/td\u003e\n\u003ctd\u003eA diaphragm tank sized to the CUE 100 instructions, between the well and the first tap\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrive location\u003c\/td\u003e\n\u003ctd\u003eWall-mounted, indoors or outdoors (NEMA 4X); keep within the drop-cable length the CUE 100 instructions allow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSand\u003c\/td\u003e\n\u003ctd\u003eUp to 50 ppm for SP 5S-25S\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eMaterials of Construction\u003c\/div\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003ePart\u003c\/th\u003e\n\u003cth\u003eMaterial\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eImpellers, chambers, strainer, cable guard\u003c\/td\u003e\n\u003ctd\u003eAISI 304 stainless steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePump shaft\u003c\/td\u003e\n\u003ctd\u003eStainless steel, EN 1.4057\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBearings\u003c\/td\u003e\n\u003ctd\u003eNBR elastomer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor\u003c\/td\u003e\n\u003ctd\u003eWater-filled Grundfos MS submersible motor, stainless steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"font-size:12.5px;color:#9B9EA3;margin-top:8px;line-height:1.55\"\u003eSource: Grundfos SP data booklet, standard S construction.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"gs-contact\"\u003eFor engineering-led sizing and selection support or a factory submittal, email \u003ca href=\"mailto:sales@watermainsupply.com\"\u003esales@watermainsupply.com\u003c\/a\u003e or call \u003ca href=\"tel:18885104036\"\u003e1-888.510.4036\u003c\/a\u003e.\u003cbr\u003e© Watermain Supply — A division of E4 Industrial LLC\u003c\/div\u003e\n\n\u003c\/div\u003e\n\u003ch5\u003eData Sheet\u003c\/h5\u003e\u003cdiv class=\"gs\"\u003e\u003cdiv class=\"gs-dl\"\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0264\/1913\/4527\/files\/CUE_100_product_Leaflet_v3_QR.pdf?v=1788919445\" target=\"_blank\" rel=\"noopener\"\u003eCUE 100 Product Leaflet\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0264\/1913\/4527\/files\/93232651_07.2024_CUE_100_online.pdf?v=1788919445\" target=\"_blank\" rel=\"noopener\"\u003eCUE 100 Installation and Operating Instructions\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0264\/1913\/4527\/files\/LSPSL002.pdf?v=1788919444\" target=\"_blank\" rel=\"noopener\"\u003eGrundfos SP Submersible Pumps Data Booklet\u003c\/a\u003e\n\u003c\/div\u003e\u003c\/div\u003e\u003ch5\u003eVideos\u003c\/h5\u003e\u003cdiv class=\"gs\"\u003e\u003cdiv class=\"gs-sec\" style=\"margin-top:6px\"\u003e\u003cdiv style=\"display:grid;grid-template-columns:repeat(auto-fit,minmax(320px,1fr));gap:16px;max-width:900px\"\u003e\n\u003cdiv style=\"position:relative;padding-bottom:56.25%;height:0;overflow:hidden\"\u003e\u003ciframe src=\"https:\/\/www.youtube.com\/embed\/JSZLNfMMIpo\" title=\"Grundfos CUE 100 overview\" style=\"position:absolute;top:0;left:0;width:100%;height:100%;border:0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture\" allowfullscreen\u003e\u003c\/iframe\u003e\u003c\/div\u003e\n\u003cdiv style=\"position:relative;padding-bottom:56.25%;height:0;overflow:hidden\"\u003e\u003ciframe src=\"https:\/\/www.youtube.com\/embed\/s-6jNIZKvAI\" title=\"Grundfos CUE 100 setup demonstration\" style=\"position:absolute;top:0;left:0;width:100%;height:100%;border:0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture\" allowfullscreen\u003e\u003c\/iframe\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/div\u003e\u003c\/div\u003e\u003ch5\u003eUnyConnect App\u003c\/h5\u003e\u003cdiv class=\"gs\"\u003e\u003cdiv class=\"gs-sec\" style=\"margin-top:6px\"\u003e\n\u003cdiv class=\"gs-h\"\u003eSet Up At The Drive Or From Your Phone\u003c\/div\u003e\n\u003cdiv class=\"gs-lead\"\u003e\u003cp\u003eThe CUE 100 is set up at the drive keypad, or over Bluetooth with the free UnyConnect app on an iOS or Android phone. UnyConnect reads status and live operating data, sets the pressure setpoint and control parameters, and shows diagnostic alarms. Remote monitoring away from the wellhead requires the appropriate integration.\u003c\/p\u003e\u003c\/div\u003e\n\u003cdiv style=\"margin-top:16px\"\u003e\n\u003ca href=\"https:\/\/apps.apple.com\/us\/app\/unyconnect\/id6443696303\" target=\"_blank\" rel=\"noopener\" style=\"display:inline-block;background:#B3122A;color:#fff!important;font-family:Arial Black,Arial,sans-serif;font-size:13px;letter-spacing:1px;text-transform:uppercase;text-decoration:none;padding:12px 24px;border-radius:999px;margin:0 10px 10px 0\"\u003eDownload for iOS\u003c\/a\u003e\u003ca href=\"https:\/\/play.google.com\/store\/apps\/details?id=com.nastec.unyconnect\u0026amp;pcampaignid=web_share\" target=\"_blank\" rel=\"noopener\" style=\"display:inline-block;background:#4A4A4F;color:#fff!important;font-family:Arial Black,Arial,sans-serif;font-size:13px;letter-spacing:1px;text-transform:uppercase;text-decoration:none;padding:12px 24px;border-radius:999px;margin:0 10px 10px 0\"\u003eDownload for Android\u003c\/a\u003e\n\u003c\/div\u003e\n\u003cp style=\"font-size:12px;color:#9B9EA3;margin-top:12px\"\u003eUnyConnect is a free app for the CUE 100 drive. Bluetooth must be enabled on the CUE 100 before pairing.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/div\u003e\u003c!-- \/TABS --\u003e","brand":"Grundfos","offers":[{"title":"Default Title","offer_id":47465163194543,"sku":"93336051","price":3691.69,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0264\/1913\/4527\/files\/Grundfox_4_in_CUE_100_Sumbersible_pump_motor_controller_package.webp?v=1788919471"},{"product_id":"grundfos-25s20-11-cue-100-well-pump-package","title":"Grundfos 25S20-11 CUE 100 Constant Pressure Well Pump Package - 2 HP, 229 ft at 25 GPM, 230V 1Ph Input - 93336055","description":"\u003c!-- TABS --\u003e\n\u003ch5\u003eDescription\u003c\/h5\u003e\n\u003cdiv class=\"gs\"\u003e\n\n\u003cdiv class=\"gs-head\"\u003e\n\u003cdiv class=\"gs-eyebrow\"\u003eGrundfos · 4 in Constant Pressure Well Pump Package\u003c\/div\u003e\n\u003cdiv class=\"gs-title\"\u003e25S20-11 CUE 100\u003c\/div\u003e\n\u003cdiv class=\"gs-sub\"\u003eConstant-pressure well water package under one Grundfos order number: a 25S20-11 stainless steel SP pump end, a 2 HP 4 in three-phase motor and a CUE 100 20 drive with its pressure transducer. Runs from 230 V single-phase service.\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"gs-badges\"\u003e\n\u003cdiv class=\"gs-badge\" style=\"background:#B3122A;color:#FFFFFF;border-color:#B3122A\"\u003e25 GPM Rated Flow\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003e229 ft at 25 GPM\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003e2 HP\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003e230V 1Ph In · 3Ph Motor\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003eConstant Pressure · Transducer Included\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003e4 in Min. Well\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003e1-1\/2 in NPT Discharge\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003eNEMA 4X Outdoor Drive\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003e64 lb Ship Weight (Package)\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eOverview\u003c\/div\u003e\n\u003cdiv class=\"gs-lead\"\u003e\n\u003cp\u003eThis package brings together the three Grundfos components of a constant-pressure well system: the 25S20-11 pump end, a 2 HP 4 in three-phase submersible motor and the CUE 100 variable-frequency drive. The drive reads the included pressure transducer and changes pump speed to hold the pressure you set as taps open and close, so the house sees steady pressure instead of a pressure switch's swing.\u003c\/p\u003e\n\u003cp\u003eThe CUE 100 takes 230 V single-phase power and makes three-phase power for the motor, so you get a three-phase pump's smooth, soft-started running on ordinary single-phase service. The drive is NEMA 4X \/ IP66 for outdoor mounting and is set up at its keypad or over Bluetooth with the free UnyConnect app.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSteady pressure.\u003c\/strong\u003e The drive holds the setpoint from one tap to full flow and slows the pump when demand drops.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStainless steel SP hydraulics.\u003c\/strong\u003e AISI 304 impellers, chambers and outer parts, a built-in check valve and a sand-handling bearing design.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDiagnostics at the wellhead.\u003c\/strong\u003e Time- and date-stamped alarms and warnings at the drive and in the app; Modbus, BACnet and Bluetooth connectivity.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"background:#FFFFFF;border:1px solid #C7CBD1;border-top:3px solid #B3122A;padding:12px 16px 12px;margin:16px 0 4px;font-size:13.5px;line-height:1.55;color:#4A4A4F\"\u003e\n\u003cdiv style=\"font-family:Arial Black,Arial,sans-serif;font-size:11px;letter-spacing:1.2px;text-transform:uppercase;color:#B3122A;margin-bottom:8px\"\u003eWhat Ships and What It Needs to Run\u003c\/div\u003e\n\u003cp style=\"margin:0 0 6px\"\u003e\u003cstrong style=\"color:#B3122A\"\u003eIncluded, under order number 93336055:\u003c\/strong\u003e the 25S20-11 SP pump end (5010011), a 2 HP 4 in three-phase MS402 motor (96465630) and the CUE 100 20 drive (92939786) with its pressure transducer. Grundfos lists them as three components of one package.\u003c\/p\u003e\n\u003cp style=\"margin:0 0 6px\"\u003e\u003cstrong style=\"color:#B3122A\"\u003eRequired, ordered separately:\u003c\/strong\u003e a diaphragm pressure tank sized to the CUE 100 instructions, drop pipe, submersible drop cable and splice kit for your setting depth, and a 230 V single-phase supply and breaker for the drive.\u003c\/p\u003e\n\u003cp style=\"margin:0 0 6px\"\u003e\u003cstrong style=\"color:#B3122A\"\u003eNever connect the motor straight to the supply.\u003c\/strong\u003e It is a three-phase motor and runs only from the CUE 100.\u003c\/p\u003e\n\u003cp style=\"margin:0\"\u003e\u003cstrong style=\"color:#B3122A\"\u003eReplacement parts:\u003c\/strong\u003e the drive alone is on our \u003ca href=\"\/products\/grundfos-cue-100-constant-pressure-drive\"\u003eGrundfos CUE 100 Constant Pressure Drive\u003c\/a\u003e listing, the motor on our \u003ca href=\"\/products\/grundfos-ms-4-in-submersible-motor\"\u003eGrundfos MS 4 in motor\u003c\/a\u003e listing and the pump end on our \u003ca href=\"\/products\/grundfos-25s-sp-4-in-submersible-pump-end\"\u003eGrundfos 25S SP pump end\u003c\/a\u003e listing.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"background:#E1E3E6;border-left:3px solid #B8BDC4;padding:8px 14px;font-size:11.5px;color:#4A4A4F;margin-top:14px;line-height:1.5\"\u003eGenuine Grundfos equipment, factory-new in original packaging — sold and supported by Watermain Supply, an independent industrial supplier.\u003c\/div\u003e\n\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eWarranty\u003c\/div\u003e\n\u003cdiv class=\"gs-lead\"\u003e\u003cp\u003e24 months from date of installation, but not more than 30 months from date of manufacture. In Grundfos's words, products are “warranted to the original user only to be free of defects in material and workmanship”; the full terms are in the installation and operating instructions on the Data Sheet tab.\u003c\/p\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eSpecifications\u003c\/div\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage order number\u003c\/td\u003e\n\u003ctd\u003e93336055\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePump end\u003c\/td\u003e\n\u003ctd\u003e25S20-11, 25 GPM rated, AISI 304 stainless steel (5010011)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor\u003c\/td\u003e\n\u003ctd\u003e2 HP, 4 in, three-phase MS402 (96465630)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrive\u003c\/td\u003e\n\u003ctd\u003eCUE 100 20, 9.5 A max motor service-factor current, NEMA 4X \/ IP66 outdoor (92939786)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrive supply\u003c\/td\u003e\n\u003ctd\u003e230 V, single phase in; three phase out to the motor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure transducer\u003c\/td\u003e\n\u003ctd\u003eIncluded with the drive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDischarge\u003c\/td\u003e\n\u003ctd\u003e1-1\/2 in NPT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum well\u003c\/td\u003e\n\u003ctd\u003e4 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping weight\u003c\/td\u003e\n\u003ctd\u003e64 lb, complete package\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"font-size:12.5px;color:#9B9EA3;margin-top:8px;line-height:1.55\"\u003eSource: Grundfos US groundwater price list, January 2026 (4 in CUE 100 packages and CUE 100 drives).\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eModels \u0026amp; Performance — Will It Do What You Need?\u003c\/div\u003e\n\u003cp style=\"font-size:13.5px;margin-bottom:10px\"\u003eThe first table reads like the curve: the head the pump adds from shut-off to the end of its curve. The second shows what it delivers while the drive holds 40, 50 or 60 PSI at your pumping water level.\u003c\/p\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003cth\u003eHP\u003c\/th\u003e\n\u003cth\u003e0 GPM (Shut-off)\u003c\/th\u003e\n\u003cth\u003e6.9 GPM\u003c\/th\u003e\n\u003cth\u003e17.1 GPM\u003c\/th\u003e\n\u003cth\u003e25 GPM (Rated)\u003c\/th\u003e\n\u003cth\u003e34.3 GPM (Max)\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e25S20-11\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e333\u003c\/td\u003e\n\u003ctd\u003e304\u003c\/td\u003e\n\u003ctd\u003e268\u003c\/td\u003e\n\u003ctd\u003e229\u003c\/td\u003e\n\u003ctd\u003e119\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"font-size:12.5px;color:#9B9EA3;margin-top:8px;line-height:1.55\"\u003eTotal head in feet. The shut-off and flow columns are read from the Grundfos 60 Hz curve for the 25S20-11, digitized from the published vector curve in the Grundfos SP 25S data sheet (60 Hz), at the nearest published point and rounded down. The (Rated) column is the nominal head Grundfos prints for the 25S20-11 at 25 GPM, verbatim. 1 ft of head = 0.433 PSI. Full curves are in the product images and on the Data Sheet tab.\u003c\/p\u003e\n\u003cp style=\"font-size:13.5px;margin-bottom:10px;margin-top:18px\"\u003e\u003cstrong\u003eWhat It Delivers at Your Set Pressure\u003c\/strong\u003e (GPM by depth to water)\u003c\/p\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSet pressure\u003c\/th\u003e\n\u003cth\u003e20 ft\u003c\/th\u003e\n\u003cth\u003e60 ft\u003c\/th\u003e\n\u003cth\u003e80 ft\u003c\/th\u003e\n\u003cth\u003e120 ft\u003c\/th\u003e\n\u003cth\u003e160 ft\u003c\/th\u003e\n\u003cth\u003e180 ft\u003c\/th\u003e\n\u003cth\u003e220 ft\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e40 PSI\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e31.8\u003c\/td\u003e\n\u003ctd\u003e30.1\u003c\/td\u003e\n\u003ctd\u003e26.3\u003c\/td\u003e\n\u003ctd\u003e20.4\u003c\/td\u003e\n\u003ctd\u003e15.9\u003c\/td\u003e\n\u003ctd\u003e6.3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e50 PSI\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e29.8\u003c\/td\u003e\n\u003ctd\u003e28.1\u003c\/td\u003e\n\u003ctd\u003e23.3\u003c\/td\u003e\n\u003ctd\u003e15.6\u003c\/td\u003e\n\u003ctd\u003e10.4\u003c\/td\u003e\n\u003ctd\u003e2.7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e60 PSI\u003c\/td\u003e\n\u003ctd\u003e31.3\u003c\/td\u003e\n\u003ctd\u003e27.6\u003c\/td\u003e\n\u003ctd\u003e25.6\u003c\/td\u003e\n\u003ctd\u003e19.3\u003c\/td\u003e\n\u003ctd\u003e9.8\u003c\/td\u003e\n\u003ctd\u003e4.9\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"font-size:12.5px;color:#9B9EA3;margin-top:8px;line-height:1.55\"\u003eGPM by depth to pumping water level, verbatim from the Grundfos 25 gpm easy selection chart for the 25S20-11 (SQ, SQE, SmartFlo and SP data booklet, 60 Hz), at full speed: the most the pump delivers while the CUE 100 holds that pressure; at lower demand the drive slows the pump. Riser and pipe friction are not included. A dash means Grundfos prints no figure: on the shallow side the flow is past the chart range, on the deep side the pump cannot hold that pressure.\u003c\/p\u003e\n\u003cdiv style=\"display:flex;flex-wrap:wrap;gap:10px;margin:22px 0 4px\"\u003e\n\u003ca href=\"\/pages\/submersible-well-pump-sizing-calculator\" style=\"flex:1 1 200px;text-align:center;display:block;background:#B3122A;color:#ffffff;font-family:Arial Black,Arial,sans-serif;font-size:12px;text-transform:uppercase;letter-spacing:1.2px;padding:11px 18px;text-decoration:none\"\u003eSubmersible Calculator\u003c\/a\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eBefore You Buy — The Limits That Decide the Fit\u003c\/div\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eCheck\u003c\/th\u003e\n\u003cth\u003eWhat to confirm\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eWell size\u003c\/td\u003e\n\u003ctd\u003e4 in or larger casing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower\u003c\/td\u003e\n\u003ctd\u003e230 V single-phase supply to the drive; the motor runs only from the drive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWater\u003c\/td\u003e\n\u003ctd\u003eUp to 104°F with at least 0.25 ft\/s flowing past the 4 in motor; drinking water up to 86°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure tank\u003c\/td\u003e\n\u003ctd\u003eA diaphragm tank sized to the CUE 100 instructions, between the well and the first tap\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrive location\u003c\/td\u003e\n\u003ctd\u003eWall-mounted, indoors or outdoors (NEMA 4X); keep within the drop-cable length the CUE 100 instructions allow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSand\u003c\/td\u003e\n\u003ctd\u003eUp to 50 ppm for SP 5S-25S\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eMaterials of Construction\u003c\/div\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003ePart\u003c\/th\u003e\n\u003cth\u003eMaterial\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eImpellers, chambers, strainer, cable guard\u003c\/td\u003e\n\u003ctd\u003eAISI 304 stainless steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePump shaft\u003c\/td\u003e\n\u003ctd\u003eStainless steel, EN 1.4057\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBearings\u003c\/td\u003e\n\u003ctd\u003eNBR elastomer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor\u003c\/td\u003e\n\u003ctd\u003eWater-filled Grundfos MS submersible motor, stainless steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"font-size:12.5px;color:#9B9EA3;margin-top:8px;line-height:1.55\"\u003eSource: Grundfos SP data booklet, standard S construction.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"gs-contact\"\u003eFor engineering-led sizing and selection support or a factory submittal, email \u003ca href=\"mailto:sales@watermainsupply.com\"\u003esales@watermainsupply.com\u003c\/a\u003e or call \u003ca href=\"tel:18885104036\"\u003e1-888.510.4036\u003c\/a\u003e.\u003cbr\u003e© Watermain Supply — A division of E4 Industrial LLC\u003c\/div\u003e\n\n\u003c\/div\u003e\n\u003ch5\u003eData Sheet\u003c\/h5\u003e\u003cdiv class=\"gs\"\u003e\u003cdiv class=\"gs-dl\"\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0264\/1913\/4527\/files\/CUE_100_product_Leaflet_v3_QR.pdf?v=1788919445\" target=\"_blank\" rel=\"noopener\"\u003eCUE 100 Product Leaflet\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0264\/1913\/4527\/files\/93232651_07.2024_CUE_100_online.pdf?v=1788919445\" target=\"_blank\" rel=\"noopener\"\u003eCUE 100 Installation and Operating Instructions\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0264\/1913\/4527\/files\/LSPSL002.pdf?v=1788919444\" target=\"_blank\" rel=\"noopener\"\u003eGrundfos SP Submersible Pumps Data Booklet\u003c\/a\u003e\n\u003c\/div\u003e\u003c\/div\u003e\u003ch5\u003eVideos\u003c\/h5\u003e\u003cdiv class=\"gs\"\u003e\u003cdiv class=\"gs-sec\" style=\"margin-top:6px\"\u003e\u003cdiv style=\"display:grid;grid-template-columns:repeat(auto-fit,minmax(320px,1fr));gap:16px;max-width:900px\"\u003e\n\u003cdiv style=\"position:relative;padding-bottom:56.25%;height:0;overflow:hidden\"\u003e\u003ciframe src=\"https:\/\/www.youtube.com\/embed\/JSZLNfMMIpo\" title=\"Grundfos CUE 100 overview\" style=\"position:absolute;top:0;left:0;width:100%;height:100%;border:0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture\" allowfullscreen\u003e\u003c\/iframe\u003e\u003c\/div\u003e\n\u003cdiv style=\"position:relative;padding-bottom:56.25%;height:0;overflow:hidden\"\u003e\u003ciframe src=\"https:\/\/www.youtube.com\/embed\/s-6jNIZKvAI\" title=\"Grundfos CUE 100 setup demonstration\" style=\"position:absolute;top:0;left:0;width:100%;height:100%;border:0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture\" allowfullscreen\u003e\u003c\/iframe\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/div\u003e\u003c\/div\u003e\u003ch5\u003eUnyConnect App\u003c\/h5\u003e\u003cdiv class=\"gs\"\u003e\u003cdiv class=\"gs-sec\" style=\"margin-top:6px\"\u003e\n\u003cdiv class=\"gs-h\"\u003eSet Up At The Drive Or From Your Phone\u003c\/div\u003e\n\u003cdiv class=\"gs-lead\"\u003e\u003cp\u003eThe CUE 100 is set up at the drive keypad, or over Bluetooth with the free UnyConnect app on an iOS or Android phone. UnyConnect reads status and live operating data, sets the pressure setpoint and control parameters, and shows diagnostic alarms. Remote monitoring away from the wellhead requires the appropriate integration.\u003c\/p\u003e\u003c\/div\u003e\n\u003cdiv style=\"margin-top:16px\"\u003e\n\u003ca href=\"https:\/\/apps.apple.com\/us\/app\/unyconnect\/id6443696303\" target=\"_blank\" rel=\"noopener\" style=\"display:inline-block;background:#B3122A;color:#fff!important;font-family:Arial Black,Arial,sans-serif;font-size:13px;letter-spacing:1px;text-transform:uppercase;text-decoration:none;padding:12px 24px;border-radius:999px;margin:0 10px 10px 0\"\u003eDownload for iOS\u003c\/a\u003e\u003ca href=\"https:\/\/play.google.com\/store\/apps\/details?id=com.nastec.unyconnect\u0026amp;pcampaignid=web_share\" target=\"_blank\" rel=\"noopener\" style=\"display:inline-block;background:#4A4A4F;color:#fff!important;font-family:Arial Black,Arial,sans-serif;font-size:13px;letter-spacing:1px;text-transform:uppercase;text-decoration:none;padding:12px 24px;border-radius:999px;margin:0 10px 10px 0\"\u003eDownload for Android\u003c\/a\u003e\n\u003c\/div\u003e\n\u003cp style=\"font-size:12px;color:#9B9EA3;margin-top:12px\"\u003eUnyConnect is a free app for the CUE 100 drive. Bluetooth must be enabled on the CUE 100 before pairing.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/div\u003e\u003c!-- \/TABS --\u003e","brand":"Grundfos","offers":[{"title":"Default Title","offer_id":47465163227311,"sku":"93336055","price":3923.56,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0264\/1913\/4527\/files\/Grundfox_4_in_CUE_100_Sumbersible_pump_motor_controller_package.webp?v=1788919471"},{"product_id":"grundfos-25s30-15-cue-100-well-pump-package","title":"Grundfos 25S30-15 CUE 100 Constant Pressure Well Pump Package - 3 HP, 314 ft at 25 GPM, 208-230V 1Ph Input - 93336057","description":"\u003c!-- TABS --\u003e\n\u003ch5\u003eDescription\u003c\/h5\u003e\n\u003cdiv class=\"gs\"\u003e\n\n\u003cdiv class=\"gs-head\"\u003e\n\u003cdiv class=\"gs-eyebrow\"\u003eGrundfos · 4 in Constant Pressure Well Pump Package\u003c\/div\u003e\n\u003cdiv class=\"gs-title\"\u003e25S30-15 CUE 100\u003c\/div\u003e\n\u003cdiv class=\"gs-sub\"\u003eConstant-pressure well water package under one Grundfos order number: a 25S30-15 stainless steel SP pump end, a 3 HP 4 in three-phase motor and a CUE 100 30 drive with its pressure transducer. Runs from 208-230 V single-phase service.\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"gs-badges\"\u003e\n\u003cdiv class=\"gs-badge\" style=\"background:#B3122A;color:#FFFFFF;border-color:#B3122A\"\u003e25 GPM Rated Flow\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003e314 ft at 25 GPM\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003e3 HP\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003e208-230V 1Ph In · 3Ph Motor\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003eConstant Pressure · Transducer Included\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003e4 in Min. Well\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003e1-1\/2 in NPT Discharge\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003eNEMA 4X Outdoor Drive\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003e82 lb Ship Weight (Package)\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eOverview\u003c\/div\u003e\n\u003cdiv class=\"gs-lead\"\u003e\n\u003cp\u003eThis package brings together the three Grundfos components of a constant-pressure well system: the 25S30-15 pump end, a 3 HP 4 in three-phase submersible motor and the CUE 100 variable-frequency drive. The drive reads the included pressure transducer and changes pump speed to hold the pressure you set as taps open and close, so the house sees steady pressure instead of a pressure switch's swing.\u003c\/p\u003e\n\u003cp\u003eThe CUE 100 takes 208-230 V single-phase power and makes three-phase power for the motor, so you get a three-phase pump's smooth, soft-started running on ordinary single-phase service. The drive is NEMA 4X \/ IP66 for outdoor mounting and is set up at its keypad or over Bluetooth with the free UnyConnect app.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSteady pressure.\u003c\/strong\u003e The drive holds the setpoint from one tap to full flow and slows the pump when demand drops.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStainless steel SP hydraulics.\u003c\/strong\u003e AISI 304 impellers, chambers and outer parts, a built-in check valve and a sand-handling bearing design.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDiagnostics at the wellhead.\u003c\/strong\u003e Time- and date-stamped alarms and warnings at the drive and in the app; Modbus, BACnet and Bluetooth connectivity.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"background:#FFFFFF;border:1px solid #C7CBD1;border-top:3px solid #B3122A;padding:12px 16px 12px;margin:16px 0 4px;font-size:13.5px;line-height:1.55;color:#4A4A4F\"\u003e\n\u003cdiv style=\"font-family:Arial Black,Arial,sans-serif;font-size:11px;letter-spacing:1.2px;text-transform:uppercase;color:#B3122A;margin-bottom:8px\"\u003eWhat Ships and What It Needs to Run\u003c\/div\u003e\n\u003cp style=\"margin:0 0 6px\"\u003e\u003cstrong style=\"color:#B3122A\"\u003eIncluded, under order number 93336057:\u003c\/strong\u003e the 25S30-15 SP pump end (5010015), a 3 HP 4 in three-phase MS4000 motor (92959950) and the CUE 100 30 drive (92939800) with its pressure transducer. Grundfos lists them as three components of one package.\u003c\/p\u003e\n\u003cp style=\"margin:0 0 6px\"\u003e\u003cstrong style=\"color:#B3122A\"\u003eRequired, ordered separately:\u003c\/strong\u003e a diaphragm pressure tank sized to the CUE 100 instructions, drop pipe, submersible drop cable and splice kit for your setting depth, and a 208-230 V single-phase supply and breaker for the drive.\u003c\/p\u003e\n\u003cp style=\"margin:0 0 6px\"\u003e\u003cstrong style=\"color:#B3122A\"\u003eNever connect the motor straight to the supply.\u003c\/strong\u003e It is a three-phase motor and runs only from the CUE 100.\u003c\/p\u003e\n\u003cp style=\"margin:0\"\u003e\u003cstrong style=\"color:#B3122A\"\u003eReplacement parts:\u003c\/strong\u003e the drive alone is on our \u003ca href=\"\/products\/grundfos-cue-100-constant-pressure-drive\"\u003eGrundfos CUE 100 Constant Pressure Drive\u003c\/a\u003e listing, the motor on our \u003ca href=\"\/products\/grundfos-ms-4-in-submersible-motor\"\u003eGrundfos MS 4 in motor\u003c\/a\u003e listing and the pump end on our \u003ca href=\"\/products\/grundfos-25s-sp-4-in-submersible-pump-end\"\u003eGrundfos 25S SP pump end\u003c\/a\u003e listing.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"background:#E1E3E6;border-left:3px solid #B8BDC4;padding:8px 14px;font-size:11.5px;color:#4A4A4F;margin-top:14px;line-height:1.5\"\u003eGenuine Grundfos equipment, factory-new in original packaging — sold and supported by Watermain Supply, an independent industrial supplier.\u003c\/div\u003e\n\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eWarranty\u003c\/div\u003e\n\u003cdiv class=\"gs-lead\"\u003e\u003cp\u003e24 months from date of installation, but not more than 30 months from date of manufacture. In Grundfos's words, products are “warranted to the original user only to be free of defects in material and workmanship”; the full terms are in the installation and operating instructions on the Data Sheet tab.\u003c\/p\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eSpecifications\u003c\/div\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage order number\u003c\/td\u003e\n\u003ctd\u003e93336057\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePump end\u003c\/td\u003e\n\u003ctd\u003e25S30-15, 25 GPM rated, AISI 304 stainless steel (5010015)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor\u003c\/td\u003e\n\u003ctd\u003e3 HP, 4 in, three-phase MS4000 (92959950)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrive\u003c\/td\u003e\n\u003ctd\u003eCUE 100 30, 12.5 A max motor service-factor current, NEMA 4X \/ IP66 outdoor (92939800)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrive supply\u003c\/td\u003e\n\u003ctd\u003e208-230 V, single phase in; three phase out to the motor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure transducer\u003c\/td\u003e\n\u003ctd\u003eIncluded with the drive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDischarge\u003c\/td\u003e\n\u003ctd\u003e1-1\/2 in NPT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum well\u003c\/td\u003e\n\u003ctd\u003e4 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping weight\u003c\/td\u003e\n\u003ctd\u003e82 lb, complete package\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"font-size:12.5px;color:#9B9EA3;margin-top:8px;line-height:1.55\"\u003eSource: Grundfos US groundwater price list, January 2026 (4 in CUE 100 packages and CUE 100 drives).\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eModels \u0026amp; Performance — Will It Do What You Need?\u003c\/div\u003e\n\u003cp style=\"font-size:13.5px;margin-bottom:10px\"\u003eThe first table reads like the curve: the head the pump adds from shut-off to the end of its curve. The second shows what it delivers while the drive holds 40, 50 or 60 PSI at your pumping water level.\u003c\/p\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003cth\u003eHP\u003c\/th\u003e\n\u003cth\u003e0 GPM (Shut-off)\u003c\/th\u003e\n\u003cth\u003e6.9 GPM\u003c\/th\u003e\n\u003cth\u003e17.1 GPM\u003c\/th\u003e\n\u003cth\u003e25 GPM (Rated)\u003c\/th\u003e\n\u003cth\u003e34.3 GPM (Max)\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e25S30-15\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003ctd\u003e455\u003c\/td\u003e\n\u003ctd\u003e416\u003c\/td\u003e\n\u003ctd\u003e368\u003c\/td\u003e\n\u003ctd\u003e314\u003c\/td\u003e\n\u003ctd\u003e165\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"font-size:12.5px;color:#9B9EA3;margin-top:8px;line-height:1.55\"\u003eTotal head in feet. The shut-off and flow columns are read from the Grundfos 60 Hz curve for the 25S30-15, digitized from the published vector curve in the Grundfos SP 25S data sheet (60 Hz), at the nearest published point and rounded down. The (Rated) column is the nominal head Grundfos prints for the 25S30-15 at 25 GPM, verbatim. 1 ft of head = 0.433 PSI. Full curves are in the product images and on the Data Sheet tab.\u003c\/p\u003e\n\u003cp style=\"font-size:13.5px;margin-bottom:10px;margin-top:18px\"\u003e\u003cstrong\u003eWhat It Delivers at Your Set Pressure\u003c\/strong\u003e (GPM by depth to water)\u003c\/p\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSet pressure\u003c\/th\u003e\n\u003cth\u003e60 ft\u003c\/th\u003e\n\u003cth\u003e100 ft\u003c\/th\u003e\n\u003cth\u003e140 ft\u003c\/th\u003e\n\u003cth\u003e180 ft\u003c\/th\u003e\n\u003cth\u003e240 ft\u003c\/th\u003e\n\u003cth\u003e280 ft\u003c\/th\u003e\n\u003cth\u003e340 ft\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e40 PSI\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e32.8\u003c\/td\u003e\n\u003ctd\u003e30.3\u003c\/td\u003e\n\u003ctd\u003e27.5\u003c\/td\u003e\n\u003ctd\u003e21.9\u003c\/td\u003e\n\u003ctd\u003e16.1\u003c\/td\u003e\n\u003ctd\u003e4.9\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e50 PSI\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e31.3\u003c\/td\u003e\n\u003ctd\u003e28.7\u003c\/td\u003e\n\u003ctd\u003e25.7\u003c\/td\u003e\n\u003ctd\u003e18.8\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003ctd\u003e2.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e60 PSI\u003c\/td\u003e\n\u003ctd\u003e32.4\u003c\/td\u003e\n\u003ctd\u003e29.8\u003c\/td\u003e\n\u003ctd\u003e27\u003c\/td\u003e\n\u003ctd\u003e23.3\u003c\/td\u003e\n\u003ctd\u003e15\u003c\/td\u003e\n\u003ctd\u003e7.6\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"font-size:12.5px;color:#9B9EA3;margin-top:8px;line-height:1.55\"\u003eGPM by depth to pumping water level, verbatim from the Grundfos 25 gpm easy selection chart for the 25S30-15 (SQ, SQE, SmartFlo and SP data booklet, 60 Hz), at full speed: the most the pump delivers while the CUE 100 holds that pressure; at lower demand the drive slows the pump. Riser and pipe friction are not included. A dash means Grundfos prints no figure: on the shallow side the flow is past the chart range, on the deep side the pump cannot hold that pressure.\u003c\/p\u003e\n\u003cdiv style=\"display:flex;flex-wrap:wrap;gap:10px;margin:22px 0 4px\"\u003e\n\u003ca href=\"\/pages\/submersible-well-pump-sizing-calculator\" style=\"flex:1 1 200px;text-align:center;display:block;background:#B3122A;color:#ffffff;font-family:Arial Black,Arial,sans-serif;font-size:12px;text-transform:uppercase;letter-spacing:1.2px;padding:11px 18px;text-decoration:none\"\u003eSubmersible Calculator\u003c\/a\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eBefore You Buy — The Limits That Decide the Fit\u003c\/div\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eCheck\u003c\/th\u003e\n\u003cth\u003eWhat to confirm\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eWell size\u003c\/td\u003e\n\u003ctd\u003e4 in or larger casing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower\u003c\/td\u003e\n\u003ctd\u003e208-230 V single-phase supply to the drive; the motor runs only from the drive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWater\u003c\/td\u003e\n\u003ctd\u003eUp to 104°F with at least 0.25 ft\/s flowing past the 4 in motor; drinking water up to 86°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure tank\u003c\/td\u003e\n\u003ctd\u003eA diaphragm tank sized to the CUE 100 instructions, between the well and the first tap\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrive location\u003c\/td\u003e\n\u003ctd\u003eWall-mounted, indoors or outdoors (NEMA 4X); keep within the drop-cable length the CUE 100 instructions allow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSand\u003c\/td\u003e\n\u003ctd\u003eUp to 50 ppm for SP 5S-25S\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eMaterials of Construction\u003c\/div\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003ePart\u003c\/th\u003e\n\u003cth\u003eMaterial\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eImpellers, chambers, strainer, cable guard\u003c\/td\u003e\n\u003ctd\u003eAISI 304 stainless steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePump shaft\u003c\/td\u003e\n\u003ctd\u003eStainless steel, EN 1.4057\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBearings\u003c\/td\u003e\n\u003ctd\u003eNBR elastomer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor\u003c\/td\u003e\n\u003ctd\u003eWater-filled Grundfos MS submersible motor, stainless steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"font-size:12.5px;color:#9B9EA3;margin-top:8px;line-height:1.55\"\u003eSource: Grundfos SP data booklet, standard S construction.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"gs-contact\"\u003eFor engineering-led sizing and selection support or a factory submittal, email \u003ca href=\"mailto:sales@watermainsupply.com\"\u003esales@watermainsupply.com\u003c\/a\u003e or call \u003ca href=\"tel:18885104036\"\u003e1-888.510.4036\u003c\/a\u003e.\u003cbr\u003e© Watermain Supply — A division of E4 Industrial LLC\u003c\/div\u003e\n\n\u003c\/div\u003e\n\u003ch5\u003eData Sheet\u003c\/h5\u003e\u003cdiv class=\"gs\"\u003e\u003cdiv class=\"gs-dl\"\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0264\/1913\/4527\/files\/CUE_100_product_Leaflet_v3_QR.pdf?v=1788919445\" target=\"_blank\" rel=\"noopener\"\u003eCUE 100 Product Leaflet\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0264\/1913\/4527\/files\/93232651_07.2024_CUE_100_online.pdf?v=1788919445\" target=\"_blank\" rel=\"noopener\"\u003eCUE 100 Installation and Operating Instructions\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0264\/1913\/4527\/files\/LSPSL002.pdf?v=1788919444\" target=\"_blank\" rel=\"noopener\"\u003eGrundfos SP Submersible Pumps Data Booklet\u003c\/a\u003e\n\u003c\/div\u003e\u003c\/div\u003e\u003ch5\u003eVideos\u003c\/h5\u003e\u003cdiv class=\"gs\"\u003e\u003cdiv class=\"gs-sec\" style=\"margin-top:6px\"\u003e\u003cdiv style=\"display:grid;grid-template-columns:repeat(auto-fit,minmax(320px,1fr));gap:16px;max-width:900px\"\u003e\n\u003cdiv style=\"position:relative;padding-bottom:56.25%;height:0;overflow:hidden\"\u003e\u003ciframe src=\"https:\/\/www.youtube.com\/embed\/JSZLNfMMIpo\" title=\"Grundfos CUE 100 overview\" style=\"position:absolute;top:0;left:0;width:100%;height:100%;border:0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture\" allowfullscreen\u003e\u003c\/iframe\u003e\u003c\/div\u003e\n\u003cdiv style=\"position:relative;padding-bottom:56.25%;height:0;overflow:hidden\"\u003e\u003ciframe src=\"https:\/\/www.youtube.com\/embed\/s-6jNIZKvAI\" title=\"Grundfos CUE 100 setup demonstration\" style=\"position:absolute;top:0;left:0;width:100%;height:100%;border:0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture\" allowfullscreen\u003e\u003c\/iframe\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/div\u003e\u003c\/div\u003e\u003ch5\u003eUnyConnect App\u003c\/h5\u003e\u003cdiv class=\"gs\"\u003e\u003cdiv class=\"gs-sec\" style=\"margin-top:6px\"\u003e\n\u003cdiv class=\"gs-h\"\u003eSet Up At The Drive Or From Your Phone\u003c\/div\u003e\n\u003cdiv class=\"gs-lead\"\u003e\u003cp\u003eThe CUE 100 is set up at the drive keypad, or over Bluetooth with the free UnyConnect app on an iOS or Android phone. UnyConnect reads status and live operating data, sets the pressure setpoint and control parameters, and shows diagnostic alarms. Remote monitoring away from the wellhead requires the appropriate integration.\u003c\/p\u003e\u003c\/div\u003e\n\u003cdiv style=\"margin-top:16px\"\u003e\n\u003ca href=\"https:\/\/apps.apple.com\/us\/app\/unyconnect\/id6443696303\" target=\"_blank\" rel=\"noopener\" style=\"display:inline-block;background:#B3122A;color:#fff!important;font-family:Arial Black,Arial,sans-serif;font-size:13px;letter-spacing:1px;text-transform:uppercase;text-decoration:none;padding:12px 24px;border-radius:999px;margin:0 10px 10px 0\"\u003eDownload for iOS\u003c\/a\u003e\u003ca href=\"https:\/\/play.google.com\/store\/apps\/details?id=com.nastec.unyconnect\u0026amp;pcampaignid=web_share\" target=\"_blank\" rel=\"noopener\" style=\"display:inline-block;background:#4A4A4F;color:#fff!important;font-family:Arial Black,Arial,sans-serif;font-size:13px;letter-spacing:1px;text-transform:uppercase;text-decoration:none;padding:12px 24px;border-radius:999px;margin:0 10px 10px 0\"\u003eDownload for Android\u003c\/a\u003e\n\u003c\/div\u003e\n\u003cp style=\"font-size:12px;color:#9B9EA3;margin-top:12px\"\u003eUnyConnect is a free app for the CUE 100 drive. Bluetooth must be enabled on the CUE 100 before pairing.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/div\u003e\u003c!-- \/TABS --\u003e","brand":"Grundfos","offers":[{"title":"Default Title","offer_id":47465163260079,"sku":"93336057","price":5280.29,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0264\/1913\/4527\/files\/Grundfox_4_in_CUE_100_Sumbersible_pump_motor_controller_package.webp?v=1788919471"},{"product_id":"grundfos-35s15-6-cue-100-well-pump-package","title":"Grundfos 35S15-6 CUE 100 Constant Pressure Well Pump Package - 1-1\/2 HP, 125-126 ft at 35 GPM, 230V 1Ph Input - 93336415","description":"\u003c!-- TABS --\u003e\n\u003ch5\u003eDescription\u003c\/h5\u003e\n\u003cdiv class=\"gs\"\u003e\n\n\u003cdiv class=\"gs-head\"\u003e\n\u003cdiv class=\"gs-eyebrow\"\u003eGrundfos · 4 in Constant Pressure Well Pump Package\u003c\/div\u003e\n\u003cdiv class=\"gs-title\"\u003e35S15-6 CUE 100\u003c\/div\u003e\n\u003cdiv class=\"gs-sub\"\u003eConstant-pressure well water package under one Grundfos order number: a 35S15-6 stainless steel SP pump end, a 1-1\/2 HP 4 in three-phase motor and a CUE 100 20 drive with its pressure transducer. Runs from 230 V single-phase service.\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"gs-badges\"\u003e\n\u003cdiv class=\"gs-badge\" style=\"background:#B3122A;color:#FFFFFF;border-color:#B3122A\"\u003e35 GPM Rated Flow\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003e125-126 ft at 35 GPM\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003e1-1\/2 HP\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003e230V 1Ph In · 3Ph Motor\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003eConstant Pressure · Transducer Included\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003e4 in Min. Well\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003e1-1\/2 in NPT Discharge\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003eNEMA 4X Outdoor Drive\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003e61 lb Ship Weight (Package)\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eOverview\u003c\/div\u003e\n\u003cdiv class=\"gs-lead\"\u003e\n\u003cp\u003eThis package brings together the three Grundfos components of a constant-pressure well system: the 35S15-6 pump end, a 1-1\/2 HP 4 in three-phase submersible motor and the CUE 100 variable-frequency drive. The drive reads the included pressure transducer and changes pump speed to hold the pressure you set as taps open and close, so the house sees steady pressure instead of a pressure switch's swing.\u003c\/p\u003e\n\u003cp\u003eThe CUE 100 takes 230 V single-phase power and makes three-phase power for the motor, so you get a three-phase pump's smooth, soft-started running on ordinary single-phase service. The drive is NEMA 4X \/ IP66 for outdoor mounting and is set up at its keypad or over Bluetooth with the free UnyConnect app.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSteady pressure.\u003c\/strong\u003e The drive holds the setpoint from one tap to full flow and slows the pump when demand drops.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStainless steel SP hydraulics.\u003c\/strong\u003e AISI 304 impellers, chambers and outer parts, a built-in check valve and a sand-handling bearing design.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDiagnostics at the wellhead.\u003c\/strong\u003e Time- and date-stamped alarms and warnings at the drive and in the app; Modbus, BACnet and Bluetooth connectivity.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"background:#FFFFFF;border:1px solid #C7CBD1;border-top:3px solid #B3122A;padding:12px 16px 12px;margin:16px 0 4px;font-size:13.5px;line-height:1.55;color:#4A4A4F\"\u003e\n\u003cdiv style=\"font-family:Arial Black,Arial,sans-serif;font-size:11px;letter-spacing:1.2px;text-transform:uppercase;color:#B3122A;margin-bottom:8px\"\u003eWhat Ships and What It Needs to Run\u003c\/div\u003e\n\u003cp style=\"margin:0 0 6px\"\u003e\u003cstrong style=\"color:#B3122A\"\u003eIncluded, under order number 93336415:\u003c\/strong\u003e the 35S15-6 SP pump end (98924021), a 1-1\/2 HP 4 in three-phase MS402 motor (96465629) and the CUE 100 20 drive (92939786) with its pressure transducer. Grundfos lists them as three components of one package.\u003c\/p\u003e\n\u003cp style=\"margin:0 0 6px\"\u003e\u003cstrong style=\"color:#B3122A\"\u003eRequired, ordered separately:\u003c\/strong\u003e a diaphragm pressure tank sized to the CUE 100 instructions, drop pipe, submersible drop cable and splice kit for your setting depth, and a 230 V single-phase supply and breaker for the drive.\u003c\/p\u003e\n\u003cp style=\"margin:0 0 6px\"\u003e\u003cstrong style=\"color:#B3122A\"\u003eNever connect the motor straight to the supply.\u003c\/strong\u003e It is a three-phase motor and runs only from the CUE 100.\u003c\/p\u003e\n\u003cp style=\"margin:0\"\u003e\u003cstrong style=\"color:#B3122A\"\u003eReplacement parts:\u003c\/strong\u003e the drive alone is on our \u003ca href=\"\/products\/grundfos-cue-100-constant-pressure-drive\"\u003eGrundfos CUE 100 Constant Pressure Drive\u003c\/a\u003e listing, the motor on our \u003ca href=\"\/products\/grundfos-ms-4-in-submersible-motor\"\u003eGrundfos MS 4 in motor\u003c\/a\u003e listing and the pump end on our \u003ca href=\"\/products\/grundfos-35s-sp-4-in-submersible-pump-end\"\u003eGrundfos 35S SP pump end\u003c\/a\u003e listing.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"background:#E1E3E6;border-left:3px solid #B8BDC4;padding:8px 14px;font-size:11.5px;color:#4A4A4F;margin-top:14px;line-height:1.5\"\u003eGenuine Grundfos equipment, factory-new in original packaging — sold and supported by Watermain Supply, an independent industrial supplier.\u003c\/div\u003e\n\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eWarranty\u003c\/div\u003e\n\u003cdiv class=\"gs-lead\"\u003e\u003cp\u003e24 months from date of installation, but not more than 30 months from date of manufacture. In Grundfos's words, products are “warranted to the original user only to be free of defects in material and workmanship”; the full terms are in the installation and operating instructions on the Data Sheet tab.\u003c\/p\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eSpecifications\u003c\/div\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage order number\u003c\/td\u003e\n\u003ctd\u003e93336415\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePump end\u003c\/td\u003e\n\u003ctd\u003e35S15-6, 35 GPM rated, AISI 304 stainless steel (98924021)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor\u003c\/td\u003e\n\u003ctd\u003e1-1\/2 HP, 4 in, three-phase MS402 (96465629)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrive\u003c\/td\u003e\n\u003ctd\u003eCUE 100 20, 9.5 A max motor service-factor current, NEMA 4X \/ IP66 outdoor (92939786)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrive supply\u003c\/td\u003e\n\u003ctd\u003e230 V, single phase in; three phase out to the motor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure transducer\u003c\/td\u003e\n\u003ctd\u003eIncluded with the drive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDischarge\u003c\/td\u003e\n\u003ctd\u003e1-1\/2 in NPT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum well\u003c\/td\u003e\n\u003ctd\u003e4 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping weight\u003c\/td\u003e\n\u003ctd\u003e61 lb, complete package\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"font-size:12.5px;color:#9B9EA3;margin-top:8px;line-height:1.55\"\u003eSource: Grundfos US groundwater price list, January 2026 (4 in CUE 100 packages and CUE 100 drives).\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eModels \u0026amp; Performance — Will It Do What You Need?\u003c\/div\u003e\n\u003cp style=\"font-size:13.5px;margin-bottom:10px\"\u003eThe first table reads like the curve: the head the pump adds from shut-off to the end of its curve. The second shows what it delivers while the drive holds 40, 50 or 60 PSI at your pumping water level.\u003c\/p\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003cth\u003eHP\u003c\/th\u003e\n\u003cth\u003e0 GPM (Shut-off)\u003c\/th\u003e\n\u003cth\u003e9.1 GPM\u003c\/th\u003e\n\u003cth\u003e22.6 GPM\u003c\/th\u003e\n\u003cth\u003e35 GPM (Rated)\u003c\/th\u003e\n\u003cth\u003e45.3 GPM (Max)\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e35S15-6\u003c\/td\u003e\n\u003ctd\u003e1-1\/2\u003c\/td\u003e\n\u003ctd\u003e180\u003c\/td\u003e\n\u003ctd\u003e170\u003c\/td\u003e\n\u003ctd\u003e157\u003c\/td\u003e\n\u003ctd\u003e125-126\u003c\/td\u003e\n\u003ctd\u003e92\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"font-size:12.5px;color:#9B9EA3;margin-top:8px;line-height:1.55\"\u003eTotal head in feet. The shut-off and flow columns are read from the Grundfos 60 Hz curve for the 35S15-6, digitized from the published vector curve in the Grundfos SP 35S data sheet (60 Hz), at the nearest published point and rounded down. The (Rated) column is the nominal head Grundfos prints for the 35S15-6 at 35 GPM, verbatim. 1 ft of head = 0.433 PSI. Full curves are in the product images and on the Data Sheet tab.\u003c\/p\u003e\n\u003cp style=\"font-size:13.5px;margin-bottom:10px;margin-top:18px\"\u003e\u003cstrong\u003eWhat It Delivers at Your Set Pressure\u003c\/strong\u003e (GPM by depth to water)\u003c\/p\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSet pressure\u003c\/th\u003e\n\u003cth\u003e20 ft\u003c\/th\u003e\n\u003cth\u003e40 ft\u003c\/th\u003e\n\u003cth\u003e60 ft\u003c\/th\u003e\n\u003cth\u003e80 ft\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e40 PSI\u003c\/td\u003e\n\u003ctd\u003e40.5\u003c\/td\u003e\n\u003ctd\u003e34.5\u003c\/td\u003e\n\u003ctd\u003e26\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e50 PSI\u003c\/td\u003e\n\u003ctd\u003e33.5\u003c\/td\u003e\n\u003ctd\u003e24.5\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e60 PSI\u003c\/td\u003e\n\u003ctd\u003e22\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"font-size:12.5px;color:#9B9EA3;margin-top:8px;line-height:1.55\"\u003eCalculated, not printed: Grundfos prints no easy selection chart for the 35S. Each cell is the flow where the published Grundfos SP 60 Hz curve for the 35S15-6 meets the depth to water plus the set pressure (2.31 ft per PSI), interpolated between published points and rounded down to 0.5 GPM, at full speed. Riser and pipe friction are not included. A dash on the shallow side means the flow runs past the end of the published curve; on the deep side, the pump cannot hold that pressure.\u003c\/p\u003e\n\u003cdiv style=\"display:flex;flex-wrap:wrap;gap:10px;margin:22px 0 4px\"\u003e\n\u003ca href=\"\/pages\/submersible-well-pump-sizing-calculator\" style=\"flex:1 1 200px;text-align:center;display:block;background:#B3122A;color:#ffffff;font-family:Arial Black,Arial,sans-serif;font-size:12px;text-transform:uppercase;letter-spacing:1.2px;padding:11px 18px;text-decoration:none\"\u003eSubmersible Calculator\u003c\/a\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eBefore You Buy — The Limits That Decide the Fit\u003c\/div\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eCheck\u003c\/th\u003e\n\u003cth\u003eWhat to confirm\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eWell size\u003c\/td\u003e\n\u003ctd\u003e4 in or larger casing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower\u003c\/td\u003e\n\u003ctd\u003e230 V single-phase supply to the drive; the motor runs only from the drive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWater\u003c\/td\u003e\n\u003ctd\u003eUp to 104°F with at least 0.25 ft\/s flowing past the 4 in motor; drinking water up to 86°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure tank\u003c\/td\u003e\n\u003ctd\u003eA diaphragm tank sized to the CUE 100 instructions, between the well and the first tap\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrive location\u003c\/td\u003e\n\u003ctd\u003eWall-mounted, indoors or outdoors (NEMA 4X); keep within the drop-cable length the CUE 100 instructions allow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eMaterials of Construction\u003c\/div\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003ePart\u003c\/th\u003e\n\u003cth\u003eMaterial\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eImpellers, chambers, strainer, cable guard\u003c\/td\u003e\n\u003ctd\u003eAISI 304 stainless steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePump shaft\u003c\/td\u003e\n\u003ctd\u003eStainless steel, EN 1.4057\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBearings\u003c\/td\u003e\n\u003ctd\u003eNBR elastomer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor\u003c\/td\u003e\n\u003ctd\u003eWater-filled Grundfos MS submersible motor, stainless steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"font-size:12.5px;color:#9B9EA3;margin-top:8px;line-height:1.55\"\u003eSource: Grundfos SP data booklet, standard S construction.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"gs-contact\"\u003eFor engineering-led sizing and selection support or a factory submittal, email \u003ca href=\"mailto:sales@watermainsupply.com\"\u003esales@watermainsupply.com\u003c\/a\u003e or call \u003ca href=\"tel:18885104036\"\u003e1-888.510.4036\u003c\/a\u003e.\u003cbr\u003e© Watermain Supply — A division of E4 Industrial LLC\u003c\/div\u003e\n\n\u003c\/div\u003e\n\u003ch5\u003eData Sheet\u003c\/h5\u003e\u003cdiv class=\"gs\"\u003e\u003cdiv class=\"gs-dl\"\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0264\/1913\/4527\/files\/CUE_100_product_Leaflet_v3_QR.pdf?v=1788919445\" target=\"_blank\" rel=\"noopener\"\u003eCUE 100 Product Leaflet\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0264\/1913\/4527\/files\/93232651_07.2024_CUE_100_online.pdf?v=1788919445\" target=\"_blank\" rel=\"noopener\"\u003eCUE 100 Installation and Operating Instructions\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0264\/1913\/4527\/files\/LSPSL002.pdf?v=1788919444\" target=\"_blank\" rel=\"noopener\"\u003eGrundfos SP Submersible Pumps Data Booklet\u003c\/a\u003e\n\u003c\/div\u003e\u003c\/div\u003e\u003ch5\u003eVideos\u003c\/h5\u003e\u003cdiv class=\"gs\"\u003e\u003cdiv class=\"gs-sec\" style=\"margin-top:6px\"\u003e\u003cdiv style=\"display:grid;grid-template-columns:repeat(auto-fit,minmax(320px,1fr));gap:16px;max-width:900px\"\u003e\n\u003cdiv style=\"position:relative;padding-bottom:56.25%;height:0;overflow:hidden\"\u003e\u003ciframe src=\"https:\/\/www.youtube.com\/embed\/JSZLNfMMIpo\" title=\"Grundfos CUE 100 overview\" style=\"position:absolute;top:0;left:0;width:100%;height:100%;border:0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture\" allowfullscreen\u003e\u003c\/iframe\u003e\u003c\/div\u003e\n\u003cdiv style=\"position:relative;padding-bottom:56.25%;height:0;overflow:hidden\"\u003e\u003ciframe src=\"https:\/\/www.youtube.com\/embed\/s-6jNIZKvAI\" title=\"Grundfos CUE 100 setup demonstration\" style=\"position:absolute;top:0;left:0;width:100%;height:100%;border:0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture\" allowfullscreen\u003e\u003c\/iframe\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/div\u003e\u003c\/div\u003e\u003ch5\u003eUnyConnect App\u003c\/h5\u003e\u003cdiv class=\"gs\"\u003e\u003cdiv class=\"gs-sec\" style=\"margin-top:6px\"\u003e\n\u003cdiv class=\"gs-h\"\u003eSet Up At The Drive Or From Your Phone\u003c\/div\u003e\n\u003cdiv class=\"gs-lead\"\u003e\u003cp\u003eThe CUE 100 is set up at the drive keypad, or over Bluetooth with the free UnyConnect app on an iOS or Android phone. UnyConnect reads status and live operating data, sets the pressure setpoint and control parameters, and shows diagnostic alarms. Remote monitoring away from the wellhead requires the appropriate integration.\u003c\/p\u003e\u003c\/div\u003e\n\u003cdiv style=\"margin-top:16px\"\u003e\n\u003ca href=\"https:\/\/apps.apple.com\/us\/app\/unyconnect\/id6443696303\" target=\"_blank\" rel=\"noopener\" style=\"display:inline-block;background:#B3122A;color:#fff!important;font-family:Arial Black,Arial,sans-serif;font-size:13px;letter-spacing:1px;text-transform:uppercase;text-decoration:none;padding:12px 24px;border-radius:999px;margin:0 10px 10px 0\"\u003eDownload for iOS\u003c\/a\u003e\u003ca href=\"https:\/\/play.google.com\/store\/apps\/details?id=com.nastec.unyconnect\u0026amp;pcampaignid=web_share\" target=\"_blank\" rel=\"noopener\" style=\"display:inline-block;background:#4A4A4F;color:#fff!important;font-family:Arial Black,Arial,sans-serif;font-size:13px;letter-spacing:1px;text-transform:uppercase;text-decoration:none;padding:12px 24px;border-radius:999px;margin:0 10px 10px 0\"\u003eDownload for Android\u003c\/a\u003e\n\u003c\/div\u003e\n\u003cp style=\"font-size:12px;color:#9B9EA3;margin-top:12px\"\u003eUnyConnect is a free app for the CUE 100 drive. Bluetooth must be enabled on the CUE 100 before pairing.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/div\u003e\u003c!-- \/TABS --\u003e","brand":"Grundfos","offers":[{"title":"Default Title","offer_id":47465163292847,"sku":"93336415","price":3224.83,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0264\/1913\/4527\/files\/Grundfox_4_in_CUE_100_Sumbersible_pump_motor_controller_package.webp?v=1788919471"},{"product_id":"grundfos-35s20-8-cue-100-well-pump-package","title":"Grundfos 35S20-8 CUE 100 Constant Pressure Well Pump Package - 2 HP, 168 ft at 35 GPM, 230V 1Ph Input - 93336417","description":"\u003c!-- TABS --\u003e\n\u003ch5\u003eDescription\u003c\/h5\u003e\n\u003cdiv class=\"gs\"\u003e\n\n\u003cdiv class=\"gs-head\"\u003e\n\u003cdiv class=\"gs-eyebrow\"\u003eGrundfos · 4 in Constant Pressure Well Pump Package\u003c\/div\u003e\n\u003cdiv class=\"gs-title\"\u003e35S20-8 CUE 100\u003c\/div\u003e\n\u003cdiv class=\"gs-sub\"\u003eConstant-pressure well water package under one Grundfos order number: a 35S20-8 stainless steel SP pump end, a 2 HP 4 in three-phase motor and a CUE 100 20 drive with its pressure transducer. Runs from 230 V single-phase service.\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"gs-badges\"\u003e\n\u003cdiv class=\"gs-badge\" style=\"background:#B3122A;color:#FFFFFF;border-color:#B3122A\"\u003e35 GPM Rated Flow\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003e168 ft at 35 GPM\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003e2 HP\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003e230V 1Ph In · 3Ph Motor\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003eConstant Pressure · Transducer Included\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003e4 in Min. Well\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003e1-1\/2 in NPT Discharge\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003eNEMA 4X Outdoor Drive\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003e73 lb Ship Weight (Package)\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eOverview\u003c\/div\u003e\n\u003cdiv class=\"gs-lead\"\u003e\n\u003cp\u003eThis package brings together the three Grundfos components of a constant-pressure well system: the 35S20-8 pump end, a 2 HP 4 in three-phase submersible motor and the CUE 100 variable-frequency drive. The drive reads the included pressure transducer and changes pump speed to hold the pressure you set as taps open and close, so the house sees steady pressure instead of a pressure switch's swing.\u003c\/p\u003e\n\u003cp\u003eThe CUE 100 takes 230 V single-phase power and makes three-phase power for the motor, so you get a three-phase pump's smooth, soft-started running on ordinary single-phase service. The drive is NEMA 4X \/ IP66 for outdoor mounting and is set up at its keypad or over Bluetooth with the free UnyConnect app.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSteady pressure.\u003c\/strong\u003e The drive holds the setpoint from one tap to full flow and slows the pump when demand drops.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStainless steel SP hydraulics.\u003c\/strong\u003e AISI 304 impellers, chambers and outer parts, a built-in check valve and a sand-handling bearing design.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDiagnostics at the wellhead.\u003c\/strong\u003e Time- and date-stamped alarms and warnings at the drive and in the app; Modbus, BACnet and Bluetooth connectivity.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"background:#FFFFFF;border:1px solid #C7CBD1;border-top:3px solid #B3122A;padding:12px 16px 12px;margin:16px 0 4px;font-size:13.5px;line-height:1.55;color:#4A4A4F\"\u003e\n\u003cdiv style=\"font-family:Arial Black,Arial,sans-serif;font-size:11px;letter-spacing:1.2px;text-transform:uppercase;color:#B3122A;margin-bottom:8px\"\u003eWhat Ships and What It Needs to Run\u003c\/div\u003e\n\u003cp style=\"margin:0 0 6px\"\u003e\u003cstrong style=\"color:#B3122A\"\u003eIncluded, under order number 93336417:\u003c\/strong\u003e the 35S20-8 SP pump end (98924022), a 2 HP 4 in three-phase MS402 motor (96465630) and the CUE 100 20 drive (92939786) with its pressure transducer. Grundfos lists them as three components of one package.\u003c\/p\u003e\n\u003cp style=\"margin:0 0 6px\"\u003e\u003cstrong style=\"color:#B3122A\"\u003eRequired, ordered separately:\u003c\/strong\u003e a diaphragm pressure tank sized to the CUE 100 instructions, drop pipe, submersible drop cable and splice kit for your setting depth, and a 230 V single-phase supply and breaker for the drive.\u003c\/p\u003e\n\u003cp style=\"margin:0 0 6px\"\u003e\u003cstrong style=\"color:#B3122A\"\u003eNever connect the motor straight to the supply.\u003c\/strong\u003e It is a three-phase motor and runs only from the CUE 100.\u003c\/p\u003e\n\u003cp style=\"margin:0\"\u003e\u003cstrong style=\"color:#B3122A\"\u003eReplacement parts:\u003c\/strong\u003e the drive alone is on our \u003ca href=\"\/products\/grundfos-cue-100-constant-pressure-drive\"\u003eGrundfos CUE 100 Constant Pressure Drive\u003c\/a\u003e listing, the motor on our \u003ca href=\"\/products\/grundfos-ms-4-in-submersible-motor\"\u003eGrundfos MS 4 in motor\u003c\/a\u003e listing and the pump end on our \u003ca href=\"\/products\/grundfos-35s-sp-4-in-submersible-pump-end\"\u003eGrundfos 35S SP pump end\u003c\/a\u003e listing.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"background:#E1E3E6;border-left:3px solid #B8BDC4;padding:8px 14px;font-size:11.5px;color:#4A4A4F;margin-top:14px;line-height:1.5\"\u003eGenuine Grundfos equipment, factory-new in original packaging — sold and supported by Watermain Supply, an independent industrial supplier.\u003c\/div\u003e\n\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eWarranty\u003c\/div\u003e\n\u003cdiv class=\"gs-lead\"\u003e\u003cp\u003e24 months from date of installation, but not more than 30 months from date of manufacture. In Grundfos's words, products are “warranted to the original user only to be free of defects in material and workmanship”; the full terms are in the installation and operating instructions on the Data Sheet tab.\u003c\/p\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eSpecifications\u003c\/div\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage order number\u003c\/td\u003e\n\u003ctd\u003e93336417\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePump end\u003c\/td\u003e\n\u003ctd\u003e35S20-8, 35 GPM rated, AISI 304 stainless steel (98924022)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor\u003c\/td\u003e\n\u003ctd\u003e2 HP, 4 in, three-phase MS402 (96465630)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrive\u003c\/td\u003e\n\u003ctd\u003eCUE 100 20, 9.5 A max motor service-factor current, NEMA 4X \/ IP66 outdoor (92939786)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrive supply\u003c\/td\u003e\n\u003ctd\u003e230 V, single phase in; three phase out to the motor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure transducer\u003c\/td\u003e\n\u003ctd\u003eIncluded with the drive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDischarge\u003c\/td\u003e\n\u003ctd\u003e1-1\/2 in NPT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum well\u003c\/td\u003e\n\u003ctd\u003e4 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping weight\u003c\/td\u003e\n\u003ctd\u003e73 lb, complete package\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"font-size:12.5px;color:#9B9EA3;margin-top:8px;line-height:1.55\"\u003eSource: Grundfos US groundwater price list, January 2026 (4 in CUE 100 packages and CUE 100 drives).\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eModels \u0026amp; Performance — Will It Do What You Need?\u003c\/div\u003e\n\u003cp style=\"font-size:13.5px;margin-bottom:10px\"\u003eThe first table reads like the curve: the head the pump adds from shut-off to the end of its curve. The second shows what it delivers while the drive holds 40, 50 or 60 PSI at your pumping water level.\u003c\/p\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003cth\u003eHP\u003c\/th\u003e\n\u003cth\u003e0 GPM (Shut-off)\u003c\/th\u003e\n\u003cth\u003e9.1 GPM\u003c\/th\u003e\n\u003cth\u003e22.6 GPM\u003c\/th\u003e\n\u003cth\u003e35 GPM (Rated)\u003c\/th\u003e\n\u003cth\u003e45.3 GPM (Max)\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e35S20-8\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e232\u003c\/td\u003e\n\u003ctd\u003e226\u003c\/td\u003e\n\u003ctd\u003e211\u003c\/td\u003e\n\u003ctd\u003e168\u003c\/td\u003e\n\u003ctd\u003e124\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"font-size:12.5px;color:#9B9EA3;margin-top:8px;line-height:1.55\"\u003eTotal head in feet. The shut-off and flow columns are read from the Grundfos 60 Hz curve for the 35S20-8, digitized from the published vector curve in the Grundfos SP 35S data sheet (60 Hz), at the nearest published point and rounded down. The (Rated) column is the nominal head Grundfos prints for the 35S20-8 at 35 GPM, verbatim. 1 ft of head = 0.433 PSI. Full curves are in the product images and on the Data Sheet tab.\u003c\/p\u003e\n\u003cp style=\"font-size:13.5px;margin-bottom:10px;margin-top:18px\"\u003e\u003cstrong\u003eWhat It Delivers at Your Set Pressure\u003c\/strong\u003e (GPM by depth to water)\u003c\/p\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSet pressure\u003c\/th\u003e\n\u003cth\u003e20 ft\u003c\/th\u003e\n\u003cth\u003e40 ft\u003c\/th\u003e\n\u003cth\u003e60 ft\u003c\/th\u003e\n\u003cth\u003e80 ft\u003c\/th\u003e\n\u003cth\u003e100 ft\u003c\/th\u003e\n\u003cth\u003e120 ft\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e40 PSI\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e44\u003c\/td\u003e\n\u003ctd\u003e40\u003c\/td\u003e\n\u003ctd\u003e35.5\u003c\/td\u003e\n\u003ctd\u003e30\u003c\/td\u003e\n\u003ctd\u003e22\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e50 PSI\u003c\/td\u003e\n\u003ctd\u003e43\u003c\/td\u003e\n\u003ctd\u003e39.5\u003c\/td\u003e\n\u003ctd\u003e35\u003c\/td\u003e\n\u003ctd\u003e29\u003c\/td\u003e\n\u003ctd\u003e20\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e60 PSI\u003c\/td\u003e\n\u003ctd\u003e39\u003c\/td\u003e\n\u003ctd\u003e34\u003c\/td\u003e\n\u003ctd\u003e28\u003c\/td\u003e\n\u003ctd\u003e18\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"font-size:12.5px;color:#9B9EA3;margin-top:8px;line-height:1.55\"\u003eCalculated, not printed: Grundfos prints no easy selection chart for the 35S. Each cell is the flow where the published Grundfos SP 60 Hz curve for the 35S20-8 meets the depth to water plus the set pressure (2.31 ft per PSI), interpolated between published points and rounded down to 0.5 GPM, at full speed. Riser and pipe friction are not included. A dash on the shallow side means the flow runs past the end of the published curve; on the deep side, the pump cannot hold that pressure.\u003c\/p\u003e\n\u003cdiv style=\"display:flex;flex-wrap:wrap;gap:10px;margin:22px 0 4px\"\u003e\n\u003ca href=\"\/pages\/submersible-well-pump-sizing-calculator\" style=\"flex:1 1 200px;text-align:center;display:block;background:#B3122A;color:#ffffff;font-family:Arial Black,Arial,sans-serif;font-size:12px;text-transform:uppercase;letter-spacing:1.2px;padding:11px 18px;text-decoration:none\"\u003eSubmersible Calculator\u003c\/a\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eBefore You Buy — The Limits That Decide the Fit\u003c\/div\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eCheck\u003c\/th\u003e\n\u003cth\u003eWhat to confirm\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eWell size\u003c\/td\u003e\n\u003ctd\u003e4 in or larger casing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower\u003c\/td\u003e\n\u003ctd\u003e230 V single-phase supply to the drive; the motor runs only from the drive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWater\u003c\/td\u003e\n\u003ctd\u003eUp to 104°F with at least 0.25 ft\/s flowing past the 4 in motor; drinking water up to 86°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure tank\u003c\/td\u003e\n\u003ctd\u003eA diaphragm tank sized to the CUE 100 instructions, between the well and the first tap\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrive location\u003c\/td\u003e\n\u003ctd\u003eWall-mounted, indoors or outdoors (NEMA 4X); keep within the drop-cable length the CUE 100 instructions allow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eMaterials of Construction\u003c\/div\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003ePart\u003c\/th\u003e\n\u003cth\u003eMaterial\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eImpellers, chambers, strainer, cable guard\u003c\/td\u003e\n\u003ctd\u003eAISI 304 stainless steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePump shaft\u003c\/td\u003e\n\u003ctd\u003eStainless steel, EN 1.4057\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBearings\u003c\/td\u003e\n\u003ctd\u003eNBR elastomer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor\u003c\/td\u003e\n\u003ctd\u003eWater-filled Grundfos MS submersible motor, stainless steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"font-size:12.5px;color:#9B9EA3;margin-top:8px;line-height:1.55\"\u003eSource: Grundfos SP data booklet, standard S construction.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"gs-contact\"\u003eFor engineering-led sizing and selection support or a factory submittal, email \u003ca href=\"mailto:sales@watermainsupply.com\"\u003esales@watermainsupply.com\u003c\/a\u003e or call \u003ca href=\"tel:18885104036\"\u003e1-888.510.4036\u003c\/a\u003e.\u003cbr\u003e© Watermain Supply — A division of E4 Industrial LLC\u003c\/div\u003e\n\n\u003c\/div\u003e\n\u003ch5\u003eData Sheet\u003c\/h5\u003e\u003cdiv class=\"gs\"\u003e\u003cdiv class=\"gs-dl\"\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0264\/1913\/4527\/files\/CUE_100_product_Leaflet_v3_QR.pdf?v=1788919445\" target=\"_blank\" rel=\"noopener\"\u003eCUE 100 Product Leaflet\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0264\/1913\/4527\/files\/93232651_07.2024_CUE_100_online.pdf?v=1788919445\" target=\"_blank\" rel=\"noopener\"\u003eCUE 100 Installation and Operating Instructions\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0264\/1913\/4527\/files\/LSPSL002.pdf?v=1788919444\" target=\"_blank\" rel=\"noopener\"\u003eGrundfos SP Submersible Pumps Data Booklet\u003c\/a\u003e\n\u003c\/div\u003e\u003c\/div\u003e\u003ch5\u003eVideos\u003c\/h5\u003e\u003cdiv class=\"gs\"\u003e\u003cdiv class=\"gs-sec\" style=\"margin-top:6px\"\u003e\u003cdiv style=\"display:grid;grid-template-columns:repeat(auto-fit,minmax(320px,1fr));gap:16px;max-width:900px\"\u003e\n\u003cdiv style=\"position:relative;padding-bottom:56.25%;height:0;overflow:hidden\"\u003e\u003ciframe src=\"https:\/\/www.youtube.com\/embed\/JSZLNfMMIpo\" title=\"Grundfos CUE 100 overview\" style=\"position:absolute;top:0;left:0;width:100%;height:100%;border:0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture\" allowfullscreen\u003e\u003c\/iframe\u003e\u003c\/div\u003e\n\u003cdiv style=\"position:relative;padding-bottom:56.25%;height:0;overflow:hidden\"\u003e\u003ciframe src=\"https:\/\/www.youtube.com\/embed\/s-6jNIZKvAI\" title=\"Grundfos CUE 100 setup demonstration\" style=\"position:absolute;top:0;left:0;width:100%;height:100%;border:0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture\" allowfullscreen\u003e\u003c\/iframe\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/div\u003e\u003c\/div\u003e\u003ch5\u003eUnyConnect App\u003c\/h5\u003e\u003cdiv class=\"gs\"\u003e\u003cdiv class=\"gs-sec\" style=\"margin-top:6px\"\u003e\n\u003cdiv class=\"gs-h\"\u003eSet Up At The Drive Or From Your Phone\u003c\/div\u003e\n\u003cdiv class=\"gs-lead\"\u003e\u003cp\u003eThe CUE 100 is set up at the drive keypad, or over Bluetooth with the free UnyConnect app on an iOS or Android phone. UnyConnect reads status and live operating data, sets the pressure setpoint and control parameters, and shows diagnostic alarms. Remote monitoring away from the wellhead requires the appropriate integration.\u003c\/p\u003e\u003c\/div\u003e\n\u003cdiv style=\"margin-top:16px\"\u003e\n\u003ca href=\"https:\/\/apps.apple.com\/us\/app\/unyconnect\/id6443696303\" target=\"_blank\" rel=\"noopener\" style=\"display:inline-block;background:#B3122A;color:#fff!important;font-family:Arial Black,Arial,sans-serif;font-size:13px;letter-spacing:1px;text-transform:uppercase;text-decoration:none;padding:12px 24px;border-radius:999px;margin:0 10px 10px 0\"\u003eDownload for iOS\u003c\/a\u003e\u003ca href=\"https:\/\/play.google.com\/store\/apps\/details?id=com.nastec.unyconnect\u0026amp;pcampaignid=web_share\" target=\"_blank\" rel=\"noopener\" style=\"display:inline-block;background:#4A4A4F;color:#fff!important;font-family:Arial Black,Arial,sans-serif;font-size:13px;letter-spacing:1px;text-transform:uppercase;text-decoration:none;padding:12px 24px;border-radius:999px;margin:0 10px 10px 0\"\u003eDownload for Android\u003c\/a\u003e\n\u003c\/div\u003e\n\u003cp style=\"font-size:12px;color:#9B9EA3;margin-top:12px\"\u003eUnyConnect is a free app for the CUE 100 drive. Bluetooth must be enabled on the CUE 100 before pairing.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/div\u003e\u003c!-- \/TABS --\u003e","brand":"Grundfos","offers":[{"title":"Default Title","offer_id":47465163325615,"sku":"93336417","price":3828.93,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0264\/1913\/4527\/files\/Grundfox_4_in_CUE_100_Sumbersible_pump_motor_controller_package.webp?v=1788919471"},{"product_id":"grundfos-35s30-11-cue-100-well-pump-package","title":"Grundfos 35S30-11 CUE 100 Constant Pressure Well Pump Package - 3 HP, 232-237 ft at 35 GPM, 208-230V 1Ph Input - 93336418","description":"\u003c!-- TABS --\u003e\n\u003ch5\u003eDescription\u003c\/h5\u003e\n\u003cdiv class=\"gs\"\u003e\n\n\u003cdiv class=\"gs-head\"\u003e\n\u003cdiv class=\"gs-eyebrow\"\u003eGrundfos · 4 in Constant Pressure Well Pump Package\u003c\/div\u003e\n\u003cdiv class=\"gs-title\"\u003e35S30-11 CUE 100\u003c\/div\u003e\n\u003cdiv class=\"gs-sub\"\u003eConstant-pressure well water package under one Grundfos order number: a 35S30-11 stainless steel SP pump end, a 3 HP 4 in three-phase motor and a CUE 100 30 drive with its pressure transducer. Runs from 208-230 V single-phase service.\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"gs-badges\"\u003e\n\u003cdiv class=\"gs-badge\" style=\"background:#B3122A;color:#FFFFFF;border-color:#B3122A\"\u003e35 GPM Rated Flow\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003e232-237 ft at 35 GPM\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003e3 HP\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003e208-230V 1Ph In · 3Ph Motor\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003eConstant Pressure · Transducer Included\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003e4 in Min. Well\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003e1-1\/2 in NPT Discharge\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003eNEMA 4X Outdoor Drive\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003e93 lb Ship Weight (Package)\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eOverview\u003c\/div\u003e\n\u003cdiv class=\"gs-lead\"\u003e\n\u003cp\u003eThis package brings together the three Grundfos components of a constant-pressure well system: the 35S30-11 pump end, a 3 HP 4 in three-phase submersible motor and the CUE 100 variable-frequency drive. The drive reads the included pressure transducer and changes pump speed to hold the pressure you set as taps open and close, so the house sees steady pressure instead of a pressure switch's swing.\u003c\/p\u003e\n\u003cp\u003eThe CUE 100 takes 208-230 V single-phase power and makes three-phase power for the motor, so you get a three-phase pump's smooth, soft-started running on ordinary single-phase service. The drive is NEMA 4X \/ IP66 for outdoor mounting and is set up at its keypad or over Bluetooth with the free UnyConnect app.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSteady pressure.\u003c\/strong\u003e The drive holds the setpoint from one tap to full flow and slows the pump when demand drops.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStainless steel SP hydraulics.\u003c\/strong\u003e AISI 304 impellers, chambers and outer parts, a built-in check valve and a sand-handling bearing design.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDiagnostics at the wellhead.\u003c\/strong\u003e Time- and date-stamped alarms and warnings at the drive and in the app; Modbus, BACnet and Bluetooth connectivity.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"background:#FFFFFF;border:1px solid #C7CBD1;border-top:3px solid #B3122A;padding:12px 16px 12px;margin:16px 0 4px;font-size:13.5px;line-height:1.55;color:#4A4A4F\"\u003e\n\u003cdiv style=\"font-family:Arial Black,Arial,sans-serif;font-size:11px;letter-spacing:1.2px;text-transform:uppercase;color:#B3122A;margin-bottom:8px\"\u003eWhat Ships and What It Needs to Run\u003c\/div\u003e\n\u003cp style=\"margin:0 0 6px\"\u003e\u003cstrong style=\"color:#B3122A\"\u003eIncluded, under order number 93336418:\u003c\/strong\u003e the 35S30-11 SP pump end (98924023), a 3 HP 4 in three-phase MS4000 motor (92959950) and the CUE 100 30 drive (92939800) with its pressure transducer. Grundfos lists them as three components of one package.\u003c\/p\u003e\n\u003cp style=\"margin:0 0 6px\"\u003e\u003cstrong style=\"color:#B3122A\"\u003eRequired, ordered separately:\u003c\/strong\u003e a diaphragm pressure tank sized to the CUE 100 instructions, drop pipe, submersible drop cable and splice kit for your setting depth, and a 208-230 V single-phase supply and breaker for the drive.\u003c\/p\u003e\n\u003cp style=\"margin:0 0 6px\"\u003e\u003cstrong style=\"color:#B3122A\"\u003eNever connect the motor straight to the supply.\u003c\/strong\u003e It is a three-phase motor and runs only from the CUE 100.\u003c\/p\u003e\n\u003cp style=\"margin:0\"\u003e\u003cstrong style=\"color:#B3122A\"\u003eReplacement parts:\u003c\/strong\u003e the drive alone is on our \u003ca href=\"\/products\/grundfos-cue-100-constant-pressure-drive\"\u003eGrundfos CUE 100 Constant Pressure Drive\u003c\/a\u003e listing, the motor on our \u003ca href=\"\/products\/grundfos-ms-4-in-submersible-motor\"\u003eGrundfos MS 4 in motor\u003c\/a\u003e listing and the pump end on our \u003ca href=\"\/products\/grundfos-35s-sp-4-in-submersible-pump-end\"\u003eGrundfos 35S SP pump end\u003c\/a\u003e listing.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv style=\"background:#E1E3E6;border-left:3px solid #B8BDC4;padding:8px 14px;font-size:11.5px;color:#4A4A4F;margin-top:14px;line-height:1.5\"\u003eGenuine Grundfos equipment, factory-new in original packaging — sold and supported by Watermain Supply, an independent industrial supplier.\u003c\/div\u003e\n\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eWarranty\u003c\/div\u003e\n\u003cdiv class=\"gs-lead\"\u003e\u003cp\u003e24 months from date of installation, but not more than 30 months from date of manufacture. In Grundfos's words, products are “warranted to the original user only to be free of defects in material and workmanship”; the full terms are in the installation and operating instructions on the Data Sheet tab.\u003c\/p\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eSpecifications\u003c\/div\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage order number\u003c\/td\u003e\n\u003ctd\u003e93336418\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePump end\u003c\/td\u003e\n\u003ctd\u003e35S30-11, 35 GPM rated, AISI 304 stainless steel (98924023)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor\u003c\/td\u003e\n\u003ctd\u003e3 HP, 4 in, three-phase MS4000 (92959950)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrive\u003c\/td\u003e\n\u003ctd\u003eCUE 100 30, 12.5 A max motor service-factor current, NEMA 4X \/ IP66 outdoor (92939800)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrive supply\u003c\/td\u003e\n\u003ctd\u003e208-230 V, single phase in; three phase out to the motor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure transducer\u003c\/td\u003e\n\u003ctd\u003eIncluded with the drive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDischarge\u003c\/td\u003e\n\u003ctd\u003e1-1\/2 in NPT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum well\u003c\/td\u003e\n\u003ctd\u003e4 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping weight\u003c\/td\u003e\n\u003ctd\u003e93 lb, complete package\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"font-size:12.5px;color:#9B9EA3;margin-top:8px;line-height:1.55\"\u003eSource: Grundfos US groundwater price list, January 2026 (4 in CUE 100 packages and CUE 100 drives).\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eModels \u0026amp; Performance — Will It Do What You Need?\u003c\/div\u003e\n\u003cp style=\"font-size:13.5px;margin-bottom:10px\"\u003eThe first table reads like the curve: the head the pump adds from shut-off to the end of its curve. The second shows what it delivers while the drive holds 40, 50 or 60 PSI at your pumping water level.\u003c\/p\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003cth\u003eHP\u003c\/th\u003e\n\u003cth\u003e0 GPM (Shut-off)\u003c\/th\u003e\n\u003cth\u003e9.1 GPM\u003c\/th\u003e\n\u003cth\u003e22.6 GPM\u003c\/th\u003e\n\u003cth\u003e35 GPM (Rated)\u003c\/th\u003e\n\u003cth\u003e45.3 GPM (Max)\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e35S30-11\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003ctd\u003e320\u003c\/td\u003e\n\u003ctd\u003e312\u003c\/td\u003e\n\u003ctd\u003e291\u003c\/td\u003e\n\u003ctd\u003e232-237\u003c\/td\u003e\n\u003ctd\u003e173\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"font-size:12.5px;color:#9B9EA3;margin-top:8px;line-height:1.55\"\u003eTotal head in feet. The shut-off and flow columns are read from the Grundfos 60 Hz curve for the 35S30-11, digitized from the published vector curve in the Grundfos SP 35S data sheet (60 Hz), at the nearest published point and rounded down. The (Rated) column is the nominal head Grundfos prints for the 35S30-11 at 35 GPM, verbatim. 1 ft of head = 0.433 PSI. Full curves are in the product images and on the Data Sheet tab.\u003c\/p\u003e\n\u003cp style=\"font-size:13.5px;margin-bottom:10px;margin-top:18px\"\u003e\u003cstrong\u003eWhat It Delivers at Your Set Pressure\u003c\/strong\u003e (GPM by depth to water)\u003c\/p\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSet pressure\u003c\/th\u003e\n\u003cth\u003e40 ft\u003c\/th\u003e\n\u003cth\u003e80 ft\u003c\/th\u003e\n\u003cth\u003e100 ft\u003c\/th\u003e\n\u003cth\u003e120 ft\u003c\/th\u003e\n\u003cth\u003e160 ft\u003c\/th\u003e\n\u003cth\u003e200 ft\u003c\/th\u003e\n\u003cth\u003e220 ft\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e40 PSI\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e43\u003c\/td\u003e\n\u003ctd\u003e40\u003c\/td\u003e\n\u003ctd\u003e33.5\u003c\/td\u003e\n\u003ctd\u003e22.5\u003c\/td\u003e\n\u003ctd\u003e9\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e50 PSI\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e42.5\u003c\/td\u003e\n\u003ctd\u003e39.5\u003c\/td\u003e\n\u003ctd\u003e36.5\u003c\/td\u003e\n\u003ctd\u003e28\u003c\/td\u003e\n\u003ctd\u003e5.5\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e60 PSI\u003c\/td\u003e\n\u003ctd\u003e44.5\u003c\/td\u003e\n\u003ctd\u003e39\u003c\/td\u003e\n\u003ctd\u003e36\u003c\/td\u003e\n\u003ctd\u003e32\u003c\/td\u003e\n\u003ctd\u003e20\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"font-size:12.5px;color:#9B9EA3;margin-top:8px;line-height:1.55\"\u003eCalculated, not printed: Grundfos prints no easy selection chart for the 35S. Each cell is the flow where the published Grundfos SP 60 Hz curve for the 35S30-11 meets the depth to water plus the set pressure (2.31 ft per PSI), interpolated between published points and rounded down to 0.5 GPM, at full speed. Riser and pipe friction are not included. A dash on the shallow side means the flow runs past the end of the published curve; on the deep side, the pump cannot hold that pressure.\u003c\/p\u003e\n\u003cdiv style=\"display:flex;flex-wrap:wrap;gap:10px;margin:22px 0 4px\"\u003e\n\u003ca href=\"\/pages\/submersible-well-pump-sizing-calculator\" style=\"flex:1 1 200px;text-align:center;display:block;background:#B3122A;color:#ffffff;font-family:Arial Black,Arial,sans-serif;font-size:12px;text-transform:uppercase;letter-spacing:1.2px;padding:11px 18px;text-decoration:none\"\u003eSubmersible Calculator\u003c\/a\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eBefore You Buy — The Limits That Decide the Fit\u003c\/div\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eCheck\u003c\/th\u003e\n\u003cth\u003eWhat to confirm\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eWell size\u003c\/td\u003e\n\u003ctd\u003e4 in or larger casing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower\u003c\/td\u003e\n\u003ctd\u003e208-230 V single-phase supply to the drive; the motor runs only from the drive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWater\u003c\/td\u003e\n\u003ctd\u003eUp to 104°F with at least 0.25 ft\/s flowing past the 4 in motor; drinking water up to 86°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure tank\u003c\/td\u003e\n\u003ctd\u003eA diaphragm tank sized to the CUE 100 instructions, between the well and the first tap\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrive location\u003c\/td\u003e\n\u003ctd\u003eWall-mounted, indoors or outdoors (NEMA 4X); keep within the drop-cable length the CUE 100 instructions allow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eMaterials of Construction\u003c\/div\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003ePart\u003c\/th\u003e\n\u003cth\u003eMaterial\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eImpellers, chambers, strainer, cable guard\u003c\/td\u003e\n\u003ctd\u003eAISI 304 stainless steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePump shaft\u003c\/td\u003e\n\u003ctd\u003eStainless steel, EN 1.4057\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBearings\u003c\/td\u003e\n\u003ctd\u003eNBR elastomer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor\u003c\/td\u003e\n\u003ctd\u003eWater-filled Grundfos MS submersible motor, stainless steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"font-size:12.5px;color:#9B9EA3;margin-top:8px;line-height:1.55\"\u003eSource: Grundfos SP data booklet, standard S construction.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"gs-contact\"\u003eFor engineering-led sizing and selection support or a factory submittal, email \u003ca href=\"mailto:sales@watermainsupply.com\"\u003esales@watermainsupply.com\u003c\/a\u003e or call \u003ca href=\"tel:18885104036\"\u003e1-888.510.4036\u003c\/a\u003e.\u003cbr\u003e© Watermain Supply — A division of E4 Industrial LLC\u003c\/div\u003e\n\n\u003c\/div\u003e\n\u003ch5\u003eData Sheet\u003c\/h5\u003e\u003cdiv class=\"gs\"\u003e\u003cdiv class=\"gs-dl\"\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0264\/1913\/4527\/files\/CUE_100_product_Leaflet_v3_QR.pdf?v=1788919445\" target=\"_blank\" rel=\"noopener\"\u003eCUE 100 Product Leaflet\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0264\/1913\/4527\/files\/93232651_07.2024_CUE_100_online.pdf?v=1788919445\" target=\"_blank\" rel=\"noopener\"\u003eCUE 100 Installation and Operating Instructions\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0264\/1913\/4527\/files\/LSPSL002.pdf?v=1788919444\" target=\"_blank\" rel=\"noopener\"\u003eGrundfos SP Submersible Pumps Data Booklet\u003c\/a\u003e\n\u003c\/div\u003e\u003c\/div\u003e\u003ch5\u003eVideos\u003c\/h5\u003e\u003cdiv class=\"gs\"\u003e\u003cdiv class=\"gs-sec\" style=\"margin-top:6px\"\u003e\u003cdiv style=\"display:grid;grid-template-columns:repeat(auto-fit,minmax(320px,1fr));gap:16px;max-width:900px\"\u003e\n\u003cdiv style=\"position:relative;padding-bottom:56.25%;height:0;overflow:hidden\"\u003e\u003ciframe src=\"https:\/\/www.youtube.com\/embed\/JSZLNfMMIpo\" title=\"Grundfos CUE 100 overview\" style=\"position:absolute;top:0;left:0;width:100%;height:100%;border:0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture\" allowfullscreen\u003e\u003c\/iframe\u003e\u003c\/div\u003e\n\u003cdiv style=\"position:relative;padding-bottom:56.25%;height:0;overflow:hidden\"\u003e\u003ciframe src=\"https:\/\/www.youtube.com\/embed\/s-6jNIZKvAI\" title=\"Grundfos CUE 100 setup demonstration\" style=\"position:absolute;top:0;left:0;width:100%;height:100%;border:0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture\" allowfullscreen\u003e\u003c\/iframe\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/div\u003e\u003c\/div\u003e\u003ch5\u003eUnyConnect App\u003c\/h5\u003e\u003cdiv class=\"gs\"\u003e\u003cdiv class=\"gs-sec\" style=\"margin-top:6px\"\u003e\n\u003cdiv class=\"gs-h\"\u003eSet Up At The Drive Or From Your Phone\u003c\/div\u003e\n\u003cdiv class=\"gs-lead\"\u003e\u003cp\u003eThe CUE 100 is set up at the drive keypad, or over Bluetooth with the free UnyConnect app on an iOS or Android phone. UnyConnect reads status and live operating data, sets the pressure setpoint and control parameters, and shows diagnostic alarms. Remote monitoring away from the wellhead requires the appropriate integration.\u003c\/p\u003e\u003c\/div\u003e\n\u003cdiv style=\"margin-top:16px\"\u003e\n\u003ca href=\"https:\/\/apps.apple.com\/us\/app\/unyconnect\/id6443696303\" target=\"_blank\" rel=\"noopener\" style=\"display:inline-block;background:#B3122A;color:#fff!important;font-family:Arial Black,Arial,sans-serif;font-size:13px;letter-spacing:1px;text-transform:uppercase;text-decoration:none;padding:12px 24px;border-radius:999px;margin:0 10px 10px 0\"\u003eDownload for iOS\u003c\/a\u003e\u003ca href=\"https:\/\/play.google.com\/store\/apps\/details?id=com.nastec.unyconnect\u0026amp;pcampaignid=web_share\" target=\"_blank\" rel=\"noopener\" style=\"display:inline-block;background:#4A4A4F;color:#fff!important;font-family:Arial Black,Arial,sans-serif;font-size:13px;letter-spacing:1px;text-transform:uppercase;text-decoration:none;padding:12px 24px;border-radius:999px;margin:0 10px 10px 0\"\u003eDownload for Android\u003c\/a\u003e\n\u003c\/div\u003e\n\u003cp style=\"font-size:12px;color:#9B9EA3;margin-top:12px\"\u003eUnyConnect is a free app for the CUE 100 drive. Bluetooth must be enabled on the CUE 100 before pairing.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/div\u003e\u003c!-- \/TABS --\u003e","brand":"Grundfos","offers":[{"title":"Default Title","offer_id":47465163358383,"sku":"93336418","price":5196.32,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0264\/1913\/4527\/files\/Grundfox_4_in_CUE_100_Sumbersible_pump_motor_controller_package.webp?v=1788919471"},{"product_id":"franklin-electric-magforce-quickpak-constant-pressure-well-pump-package","title":"Franklin Electric MagForce QuickPAK Constant Pressure Well Pump Package","description":"\u003c!-- TABS --\u003e\u003ch5\u003eDescription\u003c\/h5\u003e\u003cdiv class=\"gs\"\u003e\n\u003cdiv class=\"gs-head\"\u003e\n\u003cdiv class=\"gs-eyebrow\"\u003eFranklin Electric · Constant Pressure System\u003c\/div\u003e\n\u003cdiv class=\"gs-title\"\u003eMagForce QuickPAK Constant Pressure Well Pump Package\u003c\/div\u003e\n\u003cdiv class=\"gs-sub\"\u003e24 Franklin builds, 7-90 GPM, 1-1\/2 to 5 HP MagForce motors.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"gs-badges\"\u003e\n\u003cdiv class=\"gs-badge\" style=\"background:#B3122A;color:#FFFFFF;border-color:#B3122A\"\u003e7-90 GPM · Lifts to 1250 ft at 50 PSI\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003e1-1\/2 to 5 HP MagForce Motor\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003e208\/230 V 1Ph Supply\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003eSubDrive Connect, NEMA 3R\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003e12-17% More Efficient Motor\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003eFE Connect App\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003eFactory Set 50 PSI\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background:#FFFFFF;border:1px solid #C7CBD1;border-top:3px solid #B3122A;padding:12px 16px 12px;margin:16px 0 4px;font-size:13.5px;line-height:1.55;color:#4A4A4F\"\u003e\n\u003cdiv style=\"font-family:Arial Black,Arial,sans-serif;font-size:11px;letter-spacing:1.2px;text-transform:uppercase;color:#B3122A;margin-bottom:8px\"\u003eWhat Ships and What It Needs to Run\u003c\/div\u003e\n\u003cp style=\"margin:0 0 6px\"\u003e\u003cstrong style=\"color:#B3122A\"\u003eIncluded:\u003c\/strong\u003e the 4 in MagForce High Efficiency permanent magnet motor, the matched Franklin pump end and the SubDrive Connect drive (NEMA 3R) with its pressure transducer, as one package.\u003c\/p\u003e\n\u003cp style=\"margin:0 0 6px\"\u003e\u003cstrong style=\"color:#B3122A\"\u003ePower supply:\u003c\/strong\u003e the SubDrive Connect drive runs on 208\/230 V single-phase service and drives the 230 V three-phase MagForce motor.\u003c\/p\u003e\n\u003cp style=\"margin:0 0 6px\"\u003e\u003cstrong style=\"color:#B3122A\"\u003ePressure tank, drop cable, splice kit and pipe:\u003c\/strong\u003e sized to your installation and ordered separately; the drive works with a small pressure tank or an existing larger tank.\u003c\/p\u003e\n\u003cp style=\"margin:0\"\u003e\u003cstrong style=\"color:#B3122A\"\u003eCheck valve on 35 GPM and larger builds:\u003c\/strong\u003e Franklin supplies high capacity pumps (35 GPM and higher) in QuickPAKs without an internal check valve; plan one in the drop pipe.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eOverview\u003c\/div\u003e\n\u003cdiv class=\"gs-lead\"\u003e\n\u003cp\u003eSubDrive QuickPAK is Franklin’s all-in-one constant pressure package: a Franklin submersible pump, motor and SubDrive variable frequency drive selected to work together, so the system is chosen by flow and total dynamic head and installed as one unit.\u003c\/p\u003e\n\u003cp\u003eThis version is powered by the 4 in MagForce High Efficiency Motor. Franklin rates the MagForce motor 12-17% more efficient than the comparable three-phase induction motor, and lighter and shorter: the 5 HP motor is 7 in shorter and 18 lb lighter than a traditional system. Running less current per horsepower, MagForce motors allow on average 22% longer motor cable per wire size. The SubDrive Connect drive adds the FE Connect app for setup, settings and monitoring.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eConstant pressure across the system, with no fluctuation as faucets and appliances open and close\u003c\/li\u003e\n\u003cli\u003eMotor, pump and drive selected as one package by flow and total dynamic head\u003c\/li\u003e\n\u003cli\u003eMagForce permanent magnet motor: 12-17% more efficient than a comparable three-phase induction motor\u003c\/li\u003e\n\u003cli\u003eSmaller, lighter motor; on average 22% longer cable runs per wire size\u003c\/li\u003e\n\u003cli\u003eSubDrive Connect with FE Connect app for advanced settings and monitoring\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background:#E1E3E6;border-left:3px solid #B8BDC4;padding:8px 14px;font-size:11.5px;color:#4A4A4F;margin-top:14px;line-height:1.5\"\u003eGenuine Franklin Electric equipment, factory-new in original packaging — sold and supported by Watermain Supply, an independent industrial supplier.\u003c\/div\u003e\n\u003cdiv style=\"background:#fff;border-left:5px solid #B3122A;padding:15px 18px;margin-top:12px\"\u003e\n\u003cdiv style=\"font-family:Arial Black,Arial,sans-serif;font-size:15px;color:#B3122A;text-transform:uppercase;letter-spacing:1px;margin-bottom:6px\"\u003e12-Month Franklin Electric Warranty\u003c\/div\u003e\n\u003cp style=\"margin:0;font-size:13.5px;color:#4A4A4F;line-height:1.55\"\u003eFranklin warrants its products for \u003cstrong\u003e12 months from the date of installation, but no more than 24 months from the date of manufacture\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp style=\"margin:6px 0 0;font-size:12px;color:#9B9EA3;line-height:1.5\"\u003eSource: Franklin Electric limited warranty, Submersible Pumps AG\/Industrial\/Municipal Product Catalog.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eSpecifications\u003c\/div\u003e\n\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlow builds\u003c\/td\u003e\n\u003ctd\u003e7, 10, 15, 20, 25, 35, 45, 60 and 90 GPM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor\u003c\/td\u003e\n\u003ctd\u003e4 in MagForce permanent magnet, 230 V three-phase, 1-1\/2, 2, 3 or 5 HP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrive\u003c\/td\u003e\n\u003ctd\u003eSubDrive20, SubDrive30 or SubDrive50 Connect, NEMA 3R enclosure for indoor or outdoor use\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower supply\u003c\/td\u003e\n\u003ctd\u003e208\/230 VAC single-phase, 60\/50 Hz (SubDrive Connect)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure\u003c\/td\u003e\n\u003ctd\u003eFactory preset 50 psi; pressure transducer included for pressure display\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePump hydraulics\u003c\/td\u003e\n\u003ctd\u003e3200 Series, Tri-Seal and 4 in High Capacity pump ends, as listed per build\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBuilt-in protection\u003c\/td\u003e\n\u003ctd\u003eUnderload (dry-run) with adjustable sensitivity, overload and locked pump, undervoltage, electrical surge, broken pipe detection, output short and open circuit, overheated controller\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOther features\u003c\/td\u003e\n\u003ctd\u003eSoft start, RFI filtering, power factor correction, FE Connect app\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\n\u003cp style=\"font-size:12.5px;color:#9B9EA3;margin-top:8px;line-height:1.55\"\u003eSource: Franklin Electric SubDrive QuickPAK Constant Pressure Systems Product Catalog (M5008 04-26), pp. 3-6.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eModels \u0026amp; Performance — Will It Do What You Need?\u003c\/div\u003e\n\u003cdiv class=\"gs-lead\"\u003e\n\u003cp\u003eFind your horsepower in the row, then read across. Total head is the lift from the pumping water level, plus the system pressure the drive holds (2.31 ft for every PSI), plus friction in the drop pipe. The output tables give the flow at a 30 or 50 PSI pressure setting for your depth to water.\u003c\/p\u003e\n\u003cdetails style=\"margin:8px 0;border-top:2px solid #B3122A;padding:6px 0\"\u003e\u003csummary style=\"cursor:pointer;font-weight:bold;color:#4A4A4F\"\u003e7 GPM class · 3 builds, 1-1\/2 to 3 HP\u003c\/summary\u003e\u003cp style=\"margin-bottom:4px\"\u003e\u003cstrong\u003e7 GPM class — total head in feet (curves end at 12.9-13 GPM)\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eHP\u003c\/th\u003e\n\u003cth\u003e0 GPM (Shut-off)\u003c\/th\u003e\n\u003cth\u003e2 GPM\u003c\/th\u003e\n\u003cth\u003e6 GPM\u003c\/th\u003e\n\u003cth\u003e9 GPM\u003c\/th\u003e\n\u003cth\u003e12 GPM\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e1-1\/2 HP\u003c\/td\u003e\n\u003ctd\u003e760\u003c\/td\u003e\n\u003ctd\u003e725\u003c\/td\u003e\n\u003ctd\u003e625\u003c\/td\u003e\n\u003ctd\u003e520\u003c\/td\u003e\n\u003ctd\u003e391\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2 HP\u003c\/td\u003e\n\u003ctd\u003e1058\u003c\/td\u003e\n\u003ctd\u003e1024\u003c\/td\u003e\n\u003ctd\u003e872\u003c\/td\u003e\n\u003ctd\u003e711\u003c\/td\u003e\n\u003ctd\u003e505\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3 HP\u003c\/td\u003e\n\u003ctd\u003e1365\u003c\/td\u003e\n\u003ctd\u003e1333\u003c\/td\u003e\n\u003ctd\u003e1130\u003c\/td\u003e\n\u003ctd\u003e923\u003c\/td\u003e\n\u003ctd\u003e664\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"margin-bottom:4px\"\u003e\u003cstrong\u003eGPM at 30 PSI by depth to water\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eHP\u003c\/th\u003e\n\u003cth\u003e500 ft\u003c\/th\u003e\n\u003cth\u003e550 ft\u003c\/th\u003e\n\u003cth\u003e600 ft\u003c\/th\u003e\n\u003cth\u003e650 ft\u003c\/th\u003e\n\u003cth\u003e700 ft\u003c\/th\u003e\n\u003cth\u003e750 ft\u003c\/th\u003e\n\u003cth\u003e800 ft\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e1-1\/2 HP\u003c\/td\u003e\n\u003ctd\u003e7\u003c\/td\u003e\n\u003ctd\u003e6\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2 HP\u003c\/td\u003e\n\u003ctd\u003e11\u003c\/td\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003ctd\u003e9\u003c\/td\u003e\n\u003ctd\u003e9\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003ctd\u003e7\u003c\/td\u003e\n\u003ctd\u003e6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3 HP\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e11\u003c\/td\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003ctd\u003e9\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"margin-bottom:4px\"\u003e\u003cstrong\u003eGPM at 50 PSI by depth to water\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eHP\u003c\/th\u003e\n\u003cth\u003e500 ft\u003c\/th\u003e\n\u003cth\u003e550 ft\u003c\/th\u003e\n\u003cth\u003e600 ft\u003c\/th\u003e\n\u003cth\u003e650 ft\u003c\/th\u003e\n\u003cth\u003e700 ft\u003c\/th\u003e\n\u003cth\u003e750 ft\u003c\/th\u003e\n\u003cth\u003e800 ft\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e1-1\/2 HP\u003c\/td\u003e\n\u003ctd\u003e6\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2 HP\u003c\/td\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003ctd\u003e9\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003ctd\u003e7\u003c\/td\u003e\n\u003ctd\u003e6\u003c\/td\u003e\n\u003ctd\u003e5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3 HP\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e11\u003c\/td\u003e\n\u003ctd\u003e11\u003c\/td\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003ctd\u003e9\u003c\/td\u003e\n\u003ctd\u003e9\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails style=\"margin:8px 0;border-top:2px solid #B3122A;padding:6px 0\"\u003e\u003csummary style=\"cursor:pointer;font-weight:bold;color:#4A4A4F\"\u003e10 GPM class · 3 builds, 1-1\/2 to 3 HP\u003c\/summary\u003e\u003cp style=\"margin-bottom:4px\"\u003e\u003cstrong\u003e10 GPM class — total head in feet (curves end at 16.1-19.4 GPM)\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eHP\u003c\/th\u003e\n\u003cth\u003e0 GPM (Shut-off)\u003c\/th\u003e\n\u003cth\u003e3 GPM\u003c\/th\u003e\n\u003cth\u003e8 GPM\u003c\/th\u003e\n\u003cth\u003e12 GPM\u003c\/th\u003e\n\u003cth\u003e16 GPM\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e1-1\/2 HP\u003c\/td\u003e\n\u003ctd\u003e827\u003c\/td\u003e\n\u003ctd\u003e768\u003c\/td\u003e\n\u003ctd\u003e587\u003c\/td\u003e\n\u003ctd\u003e394\u003c\/td\u003e\n\u003ctd\u003e158\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2 HP\u003c\/td\u003e\n\u003ctd\u003e1123\u003c\/td\u003e\n\u003ctd\u003e1044\u003c\/td\u003e\n\u003ctd\u003e787\u003c\/td\u003e\n\u003ctd\u003e516\u003c\/td\u003e\n\u003ctd\u003e191\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3 HP\u003c\/td\u003e\n\u003ctd\u003e1414\u003c\/td\u003e\n\u003ctd\u003e1025\u003c\/td\u003e\n\u003ctd\u003e814\u003c\/td\u003e\n\u003ctd\u003e605\u003c\/td\u003e\n\u003ctd\u003e360\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"margin-bottom:4px\"\u003e\u003cstrong\u003eGPM at 30 PSI by depth to water\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eHP\u003c\/th\u003e\n\u003cth\u003e440 ft\u003c\/th\u003e\n\u003cth\u003e480 ft\u003c\/th\u003e\n\u003cth\u003e500 ft\u003c\/th\u003e\n\u003cth\u003e550 ft\u003c\/th\u003e\n\u003cth\u003e600 ft\u003c\/th\u003e\n\u003cth\u003e650 ft\u003c\/th\u003e\n\u003cth\u003e700 ft\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e1-1\/2 HP\u003c\/td\u003e\n\u003ctd\u003e9\u003c\/td\u003e\n\u003ctd\u003e9\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003ctd\u003e7\u003c\/td\u003e\n\u003ctd\u003e6\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2 HP\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003ctd\u003e11\u003c\/td\u003e\n\u003ctd\u003e11\u003c\/td\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003ctd\u003e9\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3 HP\u003c\/td\u003e\n\u003ctd\u003e13\u003c\/td\u003e\n\u003ctd\u003e13\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003ctd\u003e11\u003c\/td\u003e\n\u003ctd\u003e11\u003c\/td\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"margin-bottom:4px\"\u003e\u003cstrong\u003eGPM at 50 PSI by depth to water\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eHP\u003c\/th\u003e\n\u003cth\u003e440 ft\u003c\/th\u003e\n\u003cth\u003e480 ft\u003c\/th\u003e\n\u003cth\u003e500 ft\u003c\/th\u003e\n\u003cth\u003e550 ft\u003c\/th\u003e\n\u003cth\u003e600 ft\u003c\/th\u003e\n\u003cth\u003e650 ft\u003c\/th\u003e\n\u003cth\u003e700 ft\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e1-1\/2 HP\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003ctd\u003e7\u003c\/td\u003e\n\u003ctd\u003e6\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2 HP\u003c\/td\u003e\n\u003ctd\u003e11\u003c\/td\u003e\n\u003ctd\u003e11\u003c\/td\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003ctd\u003e9\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003ctd\u003e7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3 HP\u003c\/td\u003e\n\u003ctd\u003e13\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003ctd\u003e11\u003c\/td\u003e\n\u003ctd\u003e11\u003c\/td\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails style=\"margin:8px 0;border-top:2px solid #B3122A;padding:6px 0\"\u003e\u003csummary style=\"cursor:pointer;font-weight:bold;color:#4A4A4F\"\u003e15 GPM class · 3 builds, 1-1\/2 to 3 HP\u003c\/summary\u003e\u003cp style=\"margin-bottom:4px\"\u003e\u003cstrong\u003e15 GPM class — total head in feet (curves end at 24-25.4 GPM)\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eHP\u003c\/th\u003e\n\u003cth\u003e0 GPM (Shut-off)\u003c\/th\u003e\n\u003cth\u003e5 GPM\u003c\/th\u003e\n\u003cth\u003e12 GPM\u003c\/th\u003e\n\u003cth\u003e18 GPM\u003c\/th\u003e\n\u003cth\u003e24 GPM\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e1-1\/2 HP\u003c\/td\u003e\n\u003ctd\u003e467\u003c\/td\u003e\n\u003ctd\u003e427\u003c\/td\u003e\n\u003ctd\u003e365\u003c\/td\u003e\n\u003ctd\u003e275\u003c\/td\u003e\n\u003ctd\u003e151\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2 HP\u003c\/td\u003e\n\u003ctd\u003e617\u003c\/td\u003e\n\u003ctd\u003e590\u003c\/td\u003e\n\u003ctd\u003e506\u003c\/td\u003e\n\u003ctd\u003e384\u003c\/td\u003e\n\u003ctd\u003e212\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3 HP\u003c\/td\u003e\n\u003ctd\u003e859\u003c\/td\u003e\n\u003ctd\u003e806\u003c\/td\u003e\n\u003ctd\u003e667\u003c\/td\u003e\n\u003ctd\u003e485\u003c\/td\u003e\n\u003ctd\u003e248\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"margin-bottom:4px\"\u003e\u003cstrong\u003eGPM at 30 PSI by depth to water\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eHP\u003c\/th\u003e\n\u003cth\u003e140 ft\u003c\/th\u003e\n\u003cth\u003e160 ft\u003c\/th\u003e\n\u003cth\u003e180 ft\u003c\/th\u003e\n\u003cth\u003e200 ft\u003c\/th\u003e\n\u003cth\u003e240 ft\u003c\/th\u003e\n\u003cth\u003e280 ft\u003c\/th\u003e\n\u003cth\u003e320 ft\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e1-1\/2 HP\u003c\/td\u003e\n\u003ctd\u003e22\u003c\/td\u003e\n\u003ctd\u003e21\u003c\/td\u003e\n\u003ctd\u003e20\u003c\/td\u003e\n\u003ctd\u003e19\u003c\/td\u003e\n\u003ctd\u003e17\u003c\/td\u003e\n\u003ctd\u003e14\u003c\/td\u003e\n\u003ctd\u003e11\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2 HP\u003c\/td\u003e\n\u003ctd\u003e24\u003c\/td\u003e\n\u003ctd\u003e23\u003c\/td\u003e\n\u003ctd\u003e23\u003c\/td\u003e\n\u003ctd\u003e22\u003c\/td\u003e\n\u003ctd\u003e21\u003c\/td\u003e\n\u003ctd\u003e19\u003c\/td\u003e\n\u003ctd\u003e18\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3 HP\u003c\/td\u003e\n\u003ctd\u003e24\u003c\/td\u003e\n\u003ctd\u003e24\u003c\/td\u003e\n\u003ctd\u003e23\u003c\/td\u003e\n\u003ctd\u003e23\u003c\/td\u003e\n\u003ctd\u003e22\u003c\/td\u003e\n\u003ctd\u003e21\u003c\/td\u003e\n\u003ctd\u003e20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"margin-bottom:4px\"\u003e\u003cstrong\u003eGPM at 50 PSI by depth to water\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eHP\u003c\/th\u003e\n\u003cth\u003e140 ft\u003c\/th\u003e\n\u003cth\u003e160 ft\u003c\/th\u003e\n\u003cth\u003e180 ft\u003c\/th\u003e\n\u003cth\u003e200 ft\u003c\/th\u003e\n\u003cth\u003e240 ft\u003c\/th\u003e\n\u003cth\u003e280 ft\u003c\/th\u003e\n\u003cth\u003e320 ft\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e1-1\/2 HP\u003c\/td\u003e\n\u003ctd\u003e20\u003c\/td\u003e\n\u003ctd\u003e19\u003c\/td\u003e\n\u003ctd\u003e17\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003ctd\u003e14\u003c\/td\u003e\n\u003ctd\u003e11\u003c\/td\u003e\n\u003ctd\u003e6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2 HP\u003c\/td\u003e\n\u003ctd\u003e22\u003c\/td\u003e\n\u003ctd\u003e22\u003c\/td\u003e\n\u003ctd\u003e21\u003c\/td\u003e\n\u003ctd\u003e20\u003c\/td\u003e\n\u003ctd\u003e19\u003c\/td\u003e\n\u003ctd\u003e17\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3 HP\u003c\/td\u003e\n\u003ctd\u003e23\u003c\/td\u003e\n\u003ctd\u003e23\u003c\/td\u003e\n\u003ctd\u003e22\u003c\/td\u003e\n\u003ctd\u003e22\u003c\/td\u003e\n\u003ctd\u003e21\u003c\/td\u003e\n\u003ctd\u003e20\u003c\/td\u003e\n\u003ctd\u003e19\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails style=\"margin:8px 0;border-top:2px solid #B3122A;padding:6px 0\"\u003e\u003csummary style=\"cursor:pointer;font-weight:bold;color:#4A4A4F\"\u003e20 GPM class · 3 builds, 1-1\/2 to 3 HP\u003c\/summary\u003e\u003cp style=\"margin-bottom:4px\"\u003e\u003cstrong\u003e20 GPM class — total head in feet (curves end at 34.2-34.9 GPM)\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eHP\u003c\/th\u003e\n\u003cth\u003e0 GPM (Shut-off)\u003c\/th\u003e\n\u003cth\u003e7 GPM\u003c\/th\u003e\n\u003cth\u003e17 GPM\u003c\/th\u003e\n\u003cth\u003e26 GPM\u003c\/th\u003e\n\u003cth\u003e34 GPM\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e1-1\/2 HP\u003c\/td\u003e\n\u003ctd\u003e448\u003c\/td\u003e\n\u003ctd\u003e403\u003c\/td\u003e\n\u003ctd\u003e319\u003c\/td\u003e\n\u003ctd\u003e215\u003c\/td\u003e\n\u003ctd\u003e102\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2 HP\u003c\/td\u003e\n\u003ctd\u003e476\u003c\/td\u003e\n\u003ctd\u003e463\u003c\/td\u003e\n\u003ctd\u003e399\u003c\/td\u003e\n\u003ctd\u003e296\u003c\/td\u003e\n\u003ctd\u003e164\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3 HP\u003c\/td\u003e\n\u003ctd\u003e772\u003c\/td\u003e\n\u003ctd\u003e689\u003c\/td\u003e\n\u003ctd\u003e532\u003c\/td\u003e\n\u003ctd\u003e354\u003c\/td\u003e\n\u003ctd\u003e150\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"margin-bottom:4px\"\u003e\u003cstrong\u003eGPM at 30 PSI by depth to water\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eHP\u003c\/th\u003e\n\u003cth\u003e140 ft\u003c\/th\u003e\n\u003cth\u003e160 ft\u003c\/th\u003e\n\u003cth\u003e180 ft\u003c\/th\u003e\n\u003cth\u003e200 ft\u003c\/th\u003e\n\u003cth\u003e240 ft\u003c\/th\u003e\n\u003cth\u003e280 ft\u003c\/th\u003e\n\u003cth\u003e320 ft\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e1-1\/2 HP\u003c\/td\u003e\n\u003ctd\u003e26\u003c\/td\u003e\n\u003ctd\u003e25\u003c\/td\u003e\n\u003ctd\u003e23\u003c\/td\u003e\n\u003ctd\u003e22\u003c\/td\u003e\n\u003ctd\u003e18\u003c\/td\u003e\n\u003ctd\u003e14\u003c\/td\u003e\n\u003ctd\u003e9\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2 HP\u003c\/td\u003e\n\u003ctd\u003e31\u003c\/td\u003e\n\u003ctd\u003e30\u003c\/td\u003e\n\u003ctd\u003e29\u003c\/td\u003e\n\u003ctd\u003e27\u003c\/td\u003e\n\u003ctd\u003e25\u003c\/td\u003e\n\u003ctd\u003e21\u003c\/td\u003e\n\u003ctd\u003e18\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3 HP\u003c\/td\u003e\n\u003ctd\u003e32\u003c\/td\u003e\n\u003ctd\u003e31\u003c\/td\u003e\n\u003ctd\u003e30\u003c\/td\u003e\n\u003ctd\u003e29\u003c\/td\u003e\n\u003ctd\u003e28\u003c\/td\u003e\n\u003ctd\u003e26\u003c\/td\u003e\n\u003ctd\u003e24\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"margin-bottom:4px\"\u003e\u003cstrong\u003eGPM at 50 PSI by depth to water\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eHP\u003c\/th\u003e\n\u003cth\u003e140 ft\u003c\/th\u003e\n\u003cth\u003e160 ft\u003c\/th\u003e\n\u003cth\u003e180 ft\u003c\/th\u003e\n\u003cth\u003e200 ft\u003c\/th\u003e\n\u003cth\u003e240 ft\u003c\/th\u003e\n\u003cth\u003e280 ft\u003c\/th\u003e\n\u003cth\u003e320 ft\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e1-1\/2 HP\u003c\/td\u003e\n\u003ctd\u003e23\u003c\/td\u003e\n\u003ctd\u003e21\u003c\/td\u003e\n\u003ctd\u003e19\u003c\/td\u003e\n\u003ctd\u003e17\u003c\/td\u003e\n\u003ctd\u003e13\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2 HP\u003c\/td\u003e\n\u003ctd\u003e28\u003c\/td\u003e\n\u003ctd\u003e27\u003c\/td\u003e\n\u003ctd\u003e26\u003c\/td\u003e\n\u003ctd\u003e24\u003c\/td\u003e\n\u003ctd\u003e21\u003c\/td\u003e\n\u003ctd\u003e17\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3 HP\u003c\/td\u003e\n\u003ctd\u003e30\u003c\/td\u003e\n\u003ctd\u003e29\u003c\/td\u003e\n\u003ctd\u003e28\u003c\/td\u003e\n\u003ctd\u003e27\u003c\/td\u003e\n\u003ctd\u003e26\u003c\/td\u003e\n\u003ctd\u003e24\u003c\/td\u003e\n\u003ctd\u003e22\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails style=\"margin:8px 0;border-top:2px solid #B3122A;padding:6px 0\"\u003e\u003csummary style=\"cursor:pointer;font-weight:bold;color:#4A4A4F\"\u003e25 GPM class · 3 builds, 1-1\/2 to 3 HP\u003c\/summary\u003e\u003cp style=\"margin-bottom:4px\"\u003e\u003cstrong\u003e25 GPM class — total head in feet (curves end at 39.9-42.4 GPM)\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eHP\u003c\/th\u003e\n\u003cth\u003e0 GPM (Shut-off)\u003c\/th\u003e\n\u003cth\u003e8 GPM\u003c\/th\u003e\n\u003cth\u003e20 GPM\u003c\/th\u003e\n\u003cth\u003e29 GPM\u003c\/th\u003e\n\u003cth\u003e39 GPM\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e1-1\/2 HP\u003c\/td\u003e\n\u003ctd\u003e402\u003c\/td\u003e\n\u003ctd\u003e366\u003c\/td\u003e\n\u003ctd\u003e284\u003c\/td\u003e\n\u003ctd\u003e210\u003c\/td\u003e\n\u003ctd\u003e113\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2 HP\u003c\/td\u003e\n\u003ctd\u003e404\u003c\/td\u003e\n\u003ctd\u003e410\u003c\/td\u003e\n\u003ctd\u003e357\u003c\/td\u003e\n\u003ctd\u003e288\u003c\/td\u003e\n\u003ctd\u003e183\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3 HP\u003c\/td\u003e\n\u003ctd\u003e547\u003c\/td\u003e\n\u003ctd\u003e521\u003c\/td\u003e\n\u003ctd\u003e437\u003c\/td\u003e\n\u003ctd\u003e341\u003c\/td\u003e\n\u003ctd\u003e201\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"margin-bottom:4px\"\u003e\u003cstrong\u003eGPM at 30 PSI by depth to water\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eHP\u003c\/th\u003e\n\u003cth\u003e120 ft\u003c\/th\u003e\n\u003cth\u003e140 ft\u003c\/th\u003e\n\u003cth\u003e160 ft\u003c\/th\u003e\n\u003cth\u003e180 ft\u003c\/th\u003e\n\u003cth\u003e200 ft\u003c\/th\u003e\n\u003cth\u003e240 ft\u003c\/th\u003e\n\u003cth\u003e280 ft\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e1-1\/2 HP\u003c\/td\u003e\n\u003ctd\u003e30\u003c\/td\u003e\n\u003ctd\u003e28\u003c\/td\u003e\n\u003ctd\u003e26\u003c\/td\u003e\n\u003ctd\u003e24\u003c\/td\u003e\n\u003ctd\u003e21\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2 HP\u003c\/td\u003e\n\u003ctd\u003e37\u003c\/td\u003e\n\u003ctd\u003e36\u003c\/td\u003e\n\u003ctd\u003e34\u003c\/td\u003e\n\u003ctd\u003e32\u003c\/td\u003e\n\u003ctd\u003e30\u003c\/td\u003e\n\u003ctd\u003e25\u003c\/td\u003e\n\u003ctd\u003e19\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3 HP\u003c\/td\u003e\n\u003ctd\u003e40\u003c\/td\u003e\n\u003ctd\u003e38\u003c\/td\u003e\n\u003ctd\u003e37\u003c\/td\u003e\n\u003ctd\u003e36\u003c\/td\u003e\n\u003ctd\u003e34\u003c\/td\u003e\n\u003ctd\u003e31\u003c\/td\u003e\n\u003ctd\u003e28\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"margin-bottom:4px\"\u003e\u003cstrong\u003eGPM at 50 PSI by depth to water\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eHP\u003c\/th\u003e\n\u003cth\u003e120 ft\u003c\/th\u003e\n\u003cth\u003e140 ft\u003c\/th\u003e\n\u003cth\u003e160 ft\u003c\/th\u003e\n\u003cth\u003e180 ft\u003c\/th\u003e\n\u003cth\u003e200 ft\u003c\/th\u003e\n\u003cth\u003e240 ft\u003c\/th\u003e\n\u003cth\u003e280 ft\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e1-1\/2 HP\u003c\/td\u003e\n\u003ctd\u003e25\u003c\/td\u003e\n\u003ctd\u003e23\u003c\/td\u003e\n\u003ctd\u003e21\u003c\/td\u003e\n\u003ctd\u003e18\u003c\/td\u003e\n\u003ctd\u003e15\u003c\/td\u003e\n\u003ctd\u003e9\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2 HP\u003c\/td\u003e\n\u003ctd\u003e33\u003c\/td\u003e\n\u003ctd\u003e31\u003c\/td\u003e\n\u003ctd\u003e29\u003c\/td\u003e\n\u003ctd\u003e27\u003c\/td\u003e\n\u003ctd\u003e24\u003c\/td\u003e\n\u003ctd\u003e18\u003c\/td\u003e\n\u003ctd\u003e9\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3 HP\u003c\/td\u003e\n\u003ctd\u003e37\u003c\/td\u003e\n\u003ctd\u003e35\u003c\/td\u003e\n\u003ctd\u003e34\u003c\/td\u003e\n\u003ctd\u003e32\u003c\/td\u003e\n\u003ctd\u003e31\u003c\/td\u003e\n\u003ctd\u003e28\u003c\/td\u003e\n\u003ctd\u003e24\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails style=\"margin:8px 0;border-top:2px solid #B3122A;padding:6px 0\"\u003e\u003csummary style=\"cursor:pointer;font-weight:bold;color:#4A4A4F\"\u003e35 GPM class · 4 builds, 1-1\/2 to 5 HP\u003c\/summary\u003e\u003cp style=\"margin-bottom:4px\"\u003e\u003cstrong\u003e35 GPM class — total head in feet (curves end at 57.5-63.7 GPM)\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eHP\u003c\/th\u003e\n\u003cth\u003e0 GPM (Shut-off)\u003c\/th\u003e\n\u003cth\u003e11 GPM\u003c\/th\u003e\n\u003cth\u003e29 GPM\u003c\/th\u003e\n\u003cth\u003e43 GPM\u003c\/th\u003e\n\u003cth\u003e57 GPM\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e1-1\/2 HP\u003c\/td\u003e\n\u003ctd\u003e296\u003c\/td\u003e\n\u003ctd\u003e270\u003c\/td\u003e\n\u003ctd\u003e208\u003c\/td\u003e\n\u003ctd\u003e147\u003c\/td\u003e\n\u003ctd\u003e73\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2 HP\u003c\/td\u003e\n\u003ctd\u003e293\u003c\/td\u003e\n\u003ctd\u003e292\u003c\/td\u003e\n\u003ctd\u003e254\u003c\/td\u003e\n\u003ctd\u003e200\u003c\/td\u003e\n\u003ctd\u003e125\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3 HP\u003c\/td\u003e\n\u003ctd\u003e404\u003c\/td\u003e\n\u003ctd\u003e388\u003c\/td\u003e\n\u003ctd\u003e326\u003c\/td\u003e\n\u003ctd\u003e248\u003c\/td\u003e\n\u003ctd\u003e141\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5 HP\u003c\/td\u003e\n\u003ctd\u003e693\u003c\/td\u003e\n\u003ctd\u003e677\u003c\/td\u003e\n\u003ctd\u003e572\u003c\/td\u003e\n\u003ctd\u003e438\u003c\/td\u003e\n\u003ctd\u003e257\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"margin-bottom:4px\"\u003e\u003cstrong\u003eGPM at 30 PSI by depth to water\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eHP\u003c\/th\u003e\n\u003cth\u003e60 ft\u003c\/th\u003e\n\u003cth\u003e80 ft\u003c\/th\u003e\n\u003cth\u003e100 ft\u003c\/th\u003e\n\u003cth\u003e120 ft\u003c\/th\u003e\n\u003cth\u003e140 ft\u003c\/th\u003e\n\u003cth\u003e160 ft\u003c\/th\u003e\n\u003cth\u003e180 ft\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e1-1\/2 HP\u003c\/td\u003e\n\u003ctd\u003e46\u003c\/td\u003e\n\u003ctd\u003e42\u003c\/td\u003e\n\u003ctd\u003e37\u003c\/td\u003e\n\u003ctd\u003e33\u003c\/td\u003e\n\u003ctd\u003e28\u003c\/td\u003e\n\u003ctd\u003e23\u003c\/td\u003e\n\u003ctd\u003e17\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2 HP\u003c\/td\u003e\n\u003ctd\u003e55\u003c\/td\u003e\n\u003ctd\u003e52\u003c\/td\u003e\n\u003ctd\u003e48\u003c\/td\u003e\n\u003ctd\u003e44\u003c\/td\u003e\n\u003ctd\u003e40\u003c\/td\u003e\n\u003ctd\u003e35\u003c\/td\u003e\n\u003ctd\u003e30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3 HP\u003c\/td\u003e\n\u003ctd\u003e57\u003c\/td\u003e\n\u003ctd\u003e55\u003c\/td\u003e\n\u003ctd\u003e53\u003c\/td\u003e\n\u003ctd\u003e50\u003c\/td\u003e\n\u003ctd\u003e48\u003c\/td\u003e\n\u003ctd\u003e45\u003c\/td\u003e\n\u003ctd\u003e42\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5 HP\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e59\u003c\/td\u003e\n\u003ctd\u003e58\u003c\/td\u003e\n\u003ctd\u003e57\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"margin-bottom:4px\"\u003e\u003cstrong\u003eGPM at 50 PSI by depth to water\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eHP\u003c\/th\u003e\n\u003cth\u003e60 ft\u003c\/th\u003e\n\u003cth\u003e80 ft\u003c\/th\u003e\n\u003cth\u003e100 ft\u003c\/th\u003e\n\u003cth\u003e120 ft\u003c\/th\u003e\n\u003cth\u003e140 ft\u003c\/th\u003e\n\u003cth\u003e160 ft\u003c\/th\u003e\n\u003cth\u003e180 ft\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e1-1\/2 HP\u003c\/td\u003e\n\u003ctd\u003e36\u003c\/td\u003e\n\u003ctd\u003e31\u003c\/td\u003e\n\u003ctd\u003e27\u003c\/td\u003e\n\u003ctd\u003e21\u003c\/td\u003e\n\u003ctd\u003e15\u003c\/td\u003e\n\u003ctd\u003e9\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2 HP\u003c\/td\u003e\n\u003ctd\u003e47\u003c\/td\u003e\n\u003ctd\u003e43\u003c\/td\u003e\n\u003ctd\u003e39\u003c\/td\u003e\n\u003ctd\u003e34\u003c\/td\u003e\n\u003ctd\u003e28\u003c\/td\u003e\n\u003ctd\u003e20\u003c\/td\u003e\n\u003ctd\u003e5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3 HP\u003c\/td\u003e\n\u003ctd\u003e52\u003c\/td\u003e\n\u003ctd\u003e50\u003c\/td\u003e\n\u003ctd\u003e47\u003c\/td\u003e\n\u003ctd\u003e44\u003c\/td\u003e\n\u003ctd\u003e42\u003c\/td\u003e\n\u003ctd\u003e38\u003c\/td\u003e\n\u003ctd\u003e35\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5 HP\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e59\u003c\/td\u003e\n\u003ctd\u003e58\u003c\/td\u003e\n\u003ctd\u003e56\u003c\/td\u003e\n\u003ctd\u003e55\u003c\/td\u003e\n\u003ctd\u003e54\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails style=\"margin:8px 0;border-top:2px solid #B3122A;padding:6px 0\"\u003e\u003csummary style=\"cursor:pointer;font-weight:bold;color:#4A4A4F\"\u003e45 GPM class · 1 build, 5 HP\u003c\/summary\u003e\u003cp style=\"margin-bottom:4px\"\u003e\u003cstrong\u003e45 GPM class — total head in feet\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eHP\u003c\/th\u003e\n\u003cth\u003e0 GPM (Shut-off)\u003c\/th\u003e\n\u003cth\u003e14 GPM\u003c\/th\u003e\n\u003cth\u003e35 GPM\u003c\/th\u003e\n\u003cth\u003e53 GPM\u003c\/th\u003e\n\u003cth\u003e70 GPM (Max)\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\u003ctr\u003e\n\u003ctd\u003e5 HP\u003c\/td\u003e\n\u003ctd\u003e536\u003c\/td\u003e\n\u003ctd\u003e517\u003c\/td\u003e\n\u003ctd\u003e434\u003c\/td\u003e\n\u003ctd\u003e333\u003c\/td\u003e\n\u003ctd\u003e212\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"margin-bottom:4px\"\u003e\u003cstrong\u003eGPM at 30 PSI by depth to water\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eHP\u003c\/th\u003e\n\u003cth\u003e180 ft\u003c\/th\u003e\n\u003cth\u003e200 ft\u003c\/th\u003e\n\u003cth\u003e240 ft\u003c\/th\u003e\n\u003cth\u003e280 ft\u003c\/th\u003e\n\u003cth\u003e320 ft\u003c\/th\u003e\n\u003cth\u003e360 ft\u003c\/th\u003e\n\u003cth\u003e400 ft\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\u003ctr\u003e\n\u003ctd\u003e5 HP\u003c\/td\u003e\n\u003ctd\u003e65\u003c\/td\u003e\n\u003ctd\u003e62\u003c\/td\u003e\n\u003ctd\u003e56\u003c\/td\u003e\n\u003ctd\u003e50\u003c\/td\u003e\n\u003ctd\u003e44\u003c\/td\u003e\n\u003ctd\u003e36\u003c\/td\u003e\n\u003ctd\u003e27\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"margin-bottom:4px\"\u003e\u003cstrong\u003eGPM at 50 PSI by depth to water\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eHP\u003c\/th\u003e\n\u003cth\u003e180 ft\u003c\/th\u003e\n\u003cth\u003e200 ft\u003c\/th\u003e\n\u003cth\u003e240 ft\u003c\/th\u003e\n\u003cth\u003e280 ft\u003c\/th\u003e\n\u003cth\u003e320 ft\u003c\/th\u003e\n\u003cth\u003e360 ft\u003c\/th\u003e\n\u003cth\u003e400 ft\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\u003ctr\u003e\n\u003ctd\u003e5 HP\u003c\/td\u003e\n\u003ctd\u003e58\u003c\/td\u003e\n\u003ctd\u003e56\u003c\/td\u003e\n\u003ctd\u003e49\u003c\/td\u003e\n\u003ctd\u003e43\u003c\/td\u003e\n\u003ctd\u003e35\u003c\/td\u003e\n\u003ctd\u003e26\u003c\/td\u003e\n\u003ctd\u003e14\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails style=\"margin:8px 0;border-top:2px solid #B3122A;padding:6px 0\"\u003e\u003csummary style=\"cursor:pointer;font-weight:bold;color:#4A4A4F\"\u003e60 GPM class · 2 builds, 3 to 5 HP\u003c\/summary\u003e\u003cp style=\"margin-bottom:4px\"\u003e\u003cstrong\u003e60 GPM class — total head in feet (curves end at 93.9-99.6 GPM)\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eHP\u003c\/th\u003e\n\u003cth\u003e0 GPM (Shut-off)\u003c\/th\u003e\n\u003cth\u003e19 GPM\u003c\/th\u003e\n\u003cth\u003e47 GPM\u003c\/th\u003e\n\u003cth\u003e70 GPM\u003c\/th\u003e\n\u003cth\u003e93 GPM\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e3 HP\u003c\/td\u003e\n\u003ctd\u003e291\u003c\/td\u003e\n\u003ctd\u003e257\u003c\/td\u003e\n\u003ctd\u003e197\u003c\/td\u003e\n\u003ctd\u003e142\u003c\/td\u003e\n\u003ctd\u003e81\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5 HP\u003c\/td\u003e\n\u003ctd\u003e464\u003c\/td\u003e\n\u003ctd\u003e412\u003c\/td\u003e\n\u003ctd\u003e324\u003c\/td\u003e\n\u003ctd\u003e244\u003c\/td\u003e\n\u003ctd\u003e156\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"margin-bottom:4px\"\u003e\u003cstrong\u003eGPM at 30 PSI by depth to water\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eHP\u003c\/th\u003e\n\u003cth\u003e60 ft\u003c\/th\u003e\n\u003cth\u003e80 ft\u003c\/th\u003e\n\u003cth\u003e100 ft\u003c\/th\u003e\n\u003cth\u003e120 ft\u003c\/th\u003e\n\u003cth\u003e140 ft\u003c\/th\u003e\n\u003cth\u003e160 ft\u003c\/th\u003e\n\u003cth\u003e180 ft\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e3 HP\u003c\/td\u003e\n\u003ctd\u003e73\u003c\/td\u003e\n\u003ctd\u003e65\u003c\/td\u003e\n\u003ctd\u003e57\u003c\/td\u003e\n\u003ctd\u003e48\u003c\/td\u003e\n\u003ctd\u003e39\u003c\/td\u003e\n\u003ctd\u003e30\u003c\/td\u003e\n\u003ctd\u003e21\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5 HP\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e89\u003c\/td\u003e\n\u003ctd\u003e84\u003c\/td\u003e\n\u003ctd\u003e79\u003c\/td\u003e\n\u003ctd\u003e74\u003c\/td\u003e\n\u003ctd\u003e68\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"margin-bottom:4px\"\u003e\u003cstrong\u003eGPM at 50 PSI by depth to water\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eHP\u003c\/th\u003e\n\u003cth\u003e60 ft\u003c\/th\u003e\n\u003cth\u003e80 ft\u003c\/th\u003e\n\u003cth\u003e100 ft\u003c\/th\u003e\n\u003cth\u003e120 ft\u003c\/th\u003e\n\u003cth\u003e140 ft\u003c\/th\u003e\n\u003cth\u003e160 ft\u003c\/th\u003e\n\u003cth\u003e180 ft\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e3 HP\u003c\/td\u003e\n\u003ctd\u003e54\u003c\/td\u003e\n\u003ctd\u003e45\u003c\/td\u003e\n\u003ctd\u003e37\u003c\/td\u003e\n\u003ctd\u003e27\u003c\/td\u003e\n\u003ctd\u003e17\u003c\/td\u003e\n\u003ctd\u003e7\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5 HP\u003c\/td\u003e\n\u003ctd\u003e88\u003c\/td\u003e\n\u003ctd\u003e83\u003c\/td\u003e\n\u003ctd\u003e77\u003c\/td\u003e\n\u003ctd\u003e72\u003c\/td\u003e\n\u003ctd\u003e67\u003c\/td\u003e\n\u003ctd\u003e61\u003c\/td\u003e\n\u003ctd\u003e55\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cdetails style=\"margin:8px 0;border-top:2px solid #B3122A;padding:6px 0\"\u003e\u003csummary style=\"cursor:pointer;font-weight:bold;color:#4A4A4F\"\u003e90 GPM class · 2 builds, 3 to 5 HP\u003c\/summary\u003e\u003cp style=\"margin-bottom:4px\"\u003e\u003cstrong\u003e90 GPM class — total head in feet (curves end at 130-139.9 GPM)\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eHP\u003c\/th\u003e\n\u003cth\u003e0 GPM (Shut-off)\u003c\/th\u003e\n\u003cth\u003e26 GPM\u003c\/th\u003e\n\u003cth\u003e65 GPM\u003c\/th\u003e\n\u003cth\u003e98 GPM\u003c\/th\u003e\n\u003cth\u003e130 GPM\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e3 HP\u003c\/td\u003e\n\u003ctd\u003e215\u003c\/td\u003e\n\u003ctd\u003e187\u003c\/td\u003e\n\u003ctd\u003e139\u003c\/td\u003e\n\u003ctd\u003e98\u003c\/td\u003e\n\u003ctd\u003e60\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5 HP\u003c\/td\u003e\n\u003ctd\u003e342\u003c\/td\u003e\n\u003ctd\u003e300\u003c\/td\u003e\n\u003ctd\u003e233\u003c\/td\u003e\n\u003ctd\u003e175\u003c\/td\u003e\n\u003ctd\u003e116\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"margin-bottom:4px\"\u003e\u003cstrong\u003eGPM at 30 PSI by depth to water\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eHP\u003c\/th\u003e\n\u003cth\u003e20 ft\u003c\/th\u003e\n\u003cth\u003e40 ft\u003c\/th\u003e\n\u003cth\u003e60 ft\u003c\/th\u003e\n\u003cth\u003e80 ft\u003c\/th\u003e\n\u003cth\u003e100 ft\u003c\/th\u003e\n\u003cth\u003e120 ft\u003c\/th\u003e\n\u003cth\u003e140 ft\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e3 HP\u003c\/td\u003e\n\u003ctd\u003e107\u003c\/td\u003e\n\u003ctd\u003e91\u003c\/td\u003e\n\u003ctd\u003e74\u003c\/td\u003e\n\u003ctd\u003e57\u003c\/td\u003e\n\u003ctd\u003e40\u003c\/td\u003e\n\u003ctd\u003e24\u003c\/td\u003e\n\u003ctd\u003e7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5 HP\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e123\u003c\/td\u003e\n\u003ctd\u003e112\u003c\/td\u003e\n\u003ctd\u003e101\u003c\/td\u003e\n\u003ctd\u003e90\u003c\/td\u003e\n\u003ctd\u003e78\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"margin-bottom:4px\"\u003e\u003cstrong\u003eGPM at 50 PSI by depth to water\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eHP\u003c\/th\u003e\n\u003cth\u003e20 ft\u003c\/th\u003e\n\u003cth\u003e40 ft\u003c\/th\u003e\n\u003cth\u003e60 ft\u003c\/th\u003e\n\u003cth\u003e80 ft\u003c\/th\u003e\n\u003cth\u003e100 ft\u003c\/th\u003e\n\u003cth\u003e120 ft\u003c\/th\u003e\n\u003cth\u003e140 ft\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e3 HP\u003c\/td\u003e\n\u003ctd\u003e69\u003c\/td\u003e\n\u003ctd\u003e52\u003c\/td\u003e\n\u003ctd\u003e35\u003c\/td\u003e\n\u003ctd\u003e19\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5 HP\u003c\/td\u003e\n\u003ctd\u003e119\u003c\/td\u003e\n\u003ctd\u003e108\u003c\/td\u003e\n\u003ctd\u003e97\u003c\/td\u003e\n\u003ctd\u003e86\u003c\/td\u003e\n\u003ctd\u003e75\u003c\/td\u003e\n\u003ctd\u003e63\u003c\/td\u003e\n\u003ctd\u003e52\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/details\u003e\u003cp style=\"font-size:12.5px;color:#9B9EA3;margin-top:6px;line-height:1.55\"\u003eTotal head at maximum drive speed, read from the published curves in Franklin’s SubDrive QuickPAK catalog (M5008), pp. 8-51, digitized and rounded down to whole feet, at the plotted flows nearest 20%, 50% and 75% of where the curves end. 0 GPM is Franklin’s printed shut-off pressure at zero lift, in feet (PSI × 2.31). Franklin’s published curves and printed tables differ by more than 3% on the 10 GPM 3 HP and 15 GPM 1-1\/2 HP builds. The head table follows the published curve, re-checked against Franklin’s chart; the 0 GPM column and the output tables follow the printed figures. Output tables as printed in M5008, pp. 8-51, at the 30 and 50 PSI rows; Franklin rounds them to whole GPM. Drop-pipe friction is not included. — marks a point Franklin does not print.\u003c\/p\u003e\n\u003cp style=\"font-size:12.5px;color:#9B9EA3;margin-top:6px;line-height:1.55\"\u003eThe 25 GPM curves rise a few feet above the printed shut-off at low flow before they fall, so a low-flow column can read slightly above the shut-off.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBest operating range:\u003c\/strong\u003e Franklin marks the recommended operating range on each published curve and prints no figures for it. The curves are in the image gallery.\u003c\/p\u003e\n\u003cdiv style=\"display:flex;flex-wrap:wrap;gap:10px;margin:22px 0 4px\"\u003e\u003ca href=\"\/pages\/submersible-well-pump-sizing-calculator\" style=\"flex:1 1 200px;text-align:center;display:block;background:#B3122A;color:#ffffff;font-family:Arial Black,Arial,sans-serif;font-size:12px;text-transform:uppercase;letter-spacing:1.2px;padding:11px 18px;text-decoration:none\"\u003eSubmersible Calculator\u003c\/a\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eBefore You Buy — The Limits That Decide the Fit\u003c\/div\u003e\n\u003cdiv class=\"gs-lead\"\u003e\n\u003cul\u003e\n\u003cli\u003eSupply: 208\/230 V single-phase to the drive; the motor is 230 V three-phase and runs only from its SubDrive\u003c\/li\u003e\n\u003cli\u003eMatch the build to your pumping water level and pressure using the table above; Franklin’s system limit is the SubDrive, based on the maximum allowable motor amps\u003c\/li\u003e\n\u003cli\u003eSize motor cable from Franklin’s output wire sizing table for the MagForce motor (M5008, p. 6)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"gs-contact\"\u003eFor engineering-led sizing and selection support or a factory submittal, email \u003ca href=\"mailto:sales@watermainsupply.com\"\u003esales@watermainsupply.com\u003c\/a\u003e or call \u003ca href=\"tel:18885104036\"\u003e1-888.510.4036\u003c\/a\u003e.\u003cbr\u003e© Watermain Supply — A division of E4 Industrial LLC\u003c\/div\u003e\n\u003c\/div\u003e\u003ch5\u003eData Sheet\u003c\/h5\u003e\u003cdiv class=\"gs\"\u003e\u003cdiv class=\"gs-dl\"\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0264\/1913\/4527\/files\/SubDrive_QuickPAK_Constant_Pressure_Systems_Catalog_M5008.pdf?v=1791088118\" target=\"_blank\" rel=\"noopener\"\u003eSubDrive QuickPAK Constant Pressure Systems Catalog (M5008)\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0264\/1913\/4527\/files\/4-Inch_MagForce_Spec_Sheet_M5307.pdf?v=1791090213\" target=\"_blank\" rel=\"noopener\"\u003e4 in MagForce High Efficiency Motor Spec Sheet (M5307)\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0264\/1913\/4527\/files\/SubDrive_Connect_Owners_Manual.pdf?v=1791090213\" target=\"_blank\" rel=\"noopener\"\u003eSubDrive Connect Owner’s Manual\u003c\/a\u003e\n\u003c\/div\u003e\u003c\/div\u003e\u003ch5\u003eVideos\u003c\/h5\u003e\u003cdiv class=\"gs\"\u003e\u003cdiv class=\"gs-sec\" style=\"margin-top:6px\"\u003e\u003cp style=\"font-size:13px;color:#9B9EA3\"\u003eProduct videos are being added to this listing. For a walkthrough in the meantime, email sales@watermainsupply.com.\u003c\/p\u003e\u003c\/div\u003e\u003c\/div\u003e\u003c!-- \/TABS --\u003e","brand":"Franklin Electric","offers":[{"title":"7 GPM \/ 1-1\/2 HP - 7PMQP-1.5HP-3RC","offer_id":50562113896623,"sku":"93806224C","price":4182.93,"currency_code":"USD","in_stock":true},{"title":"7 GPM \/ 2 HP - 7PMQP-2.0HP-3RC","offer_id":50562113929391,"sku":"93806425C","price":4650.18,"currency_code":"USD","in_stock":true},{"title":"7 GPM \/ 3 HP - 7PMQP-3.0HP-3RC","offer_id":50562113962159,"sku":"93806526C","price":5860.68,"currency_code":"USD","in_stock":true},{"title":"10 GPM \/ 1-1\/2 HP - 10PMQP-1.5HP-3RC","offer_id":50562113994927,"sku":"93806234C","price":4008.18,"currency_code":"USD","in_stock":true},{"title":"10 GPM \/ 2 HP - 10PMQP-2.0HP-3RC","offer_id":50562114027695,"sku":"93806435C","price":4458.18,"currency_code":"USD","in_stock":true},{"title":"10 GPM \/ 3 HP - 10PMQP-3.0HP-3RC","offer_id":50562114060463,"sku":"93806536C","price":6150.93,"currency_code":"USD","in_stock":true},{"title":"15 GPM \/ 1-1\/2 HP - 15PMQP-1.5HP-3RC","offer_id":50562114093231,"sku":"93806244C","price":4013.43,"currency_code":"USD","in_stock":true},{"title":"15 GPM \/ 2 HP - 15PMQP-2.0HP-3RC","offer_id":50562114125999,"sku":"93806445C","price":4326.18,"currency_code":"USD","in_stock":true},{"title":"15 GPM \/ 3 HP - 15PMQP-3.0HP-3RC","offer_id":50562114158767,"sku":"93806546C","price":5527.68,"currency_code":"USD","in_stock":true},{"title":"20 GPM \/ 1-1\/2 HP - 20PMQP-1.5HP-3RC","offer_id":50562114191535,"sku":"93806254C","price":4224.18,"currency_code":"USD","in_stock":true},{"title":"20 GPM \/ 2 HP - 20PMQP-2.0HP-3RC","offer_id":50562114224303,"sku":"93806455C","price":4439.43,"currency_code":"USD","in_stock":true},{"title":"20 GPM \/ 3 HP - 20PMQP-3.0HP-3RC","offer_id":50562114257071,"sku":"93806556C","price":5920.68,"currency_code":"USD","in_stock":true},{"title":"25 GPM \/ 1-1\/2 HP - 25PMQP-1.5HP-3RC","offer_id":50562114289839,"sku":"93806264C","price":4079.43,"currency_code":"USD","in_stock":true},{"title":"25 GPM \/ 2 HP - 25PMQP-2.0HP-3RC","offer_id":50562114322607,"sku":"93806465C","price":4294.68,"currency_code":"USD","in_stock":true},{"title":"25 GPM \/ 3 HP - 25PMQP-3.0HP-3RC","offer_id":50562114355375,"sku":"93806566C","price":5640.93,"currency_code":"USD","in_stock":true},{"title":"35 GPM \/ 1-1\/2 HP - 35PMQP-1.5HP-3RC","offer_id":50562114388143,"sku":"93806274C","price":4458.99,"currency_code":"USD","in_stock":true},{"title":"35 GPM \/ 2 HP - 35PMQP-2.0HP-3RC","offer_id":50562114420911,"sku":"93806475C","price":4674.99,"currency_code":"USD","in_stock":true},{"title":"35 GPM \/ 3 HP - 35PMQP-3.0HP-3RC","offer_id":50562114453679,"sku":"93806576C","price":5755.74,"currency_code":"USD","in_stock":true},{"title":"35 GPM \/ 5 HP - 35PMQP-5.0HP-3RC","offer_id":50562114486447,"sku":"93806600C","price":8081.49,"currency_code":"USD","in_stock":true},{"title":"45 GPM \/ 5 HP - 45PMQP-5.0HP-3RC","offer_id":50562114519215,"sku":"93806601C","price":8125.68,"currency_code":"USD","in_stock":true},{"title":"60 GPM \/ 3 HP - 60PMQP-3.0HP-3RC","offer_id":50562114551983,"sku":"93806586C","price":6027.24,"currency_code":"USD","in_stock":true},{"title":"60 GPM \/ 5 HP - 60PMQP-5.0HP-3RC","offer_id":50562114584751,"sku":"93806602C","price":7725.99,"currency_code":"USD","in_stock":true},{"title":"90 GPM \/ 3 HP - 90PMQP-3.0HP-3RC","offer_id":50562114617519,"sku":"93806596C","price":5970.24,"currency_code":"USD","in_stock":true},{"title":"90 GPM \/ 5 HP - 90PMQP-5.0HP-3RC","offer_id":50562114650287,"sku":"93806603C","price":8002.74,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0264\/1913\/4527\/files\/SubDrive-QuickPAK_Packaged-System-with-Carton_View-2_a9e55fda-d71f-412b-ab1f-4fe6f73ddfcb.jpg?v=1791088883"},{"product_id":"franklin-electric-subdrive-monodrive-constant-pressure-controller","title":"Franklin Electric SubDrive and MonoDrive Constant Pressure Controller","description":"\u003c!-- TABS --\u003e\u003ch5\u003eDescription\u003c\/h5\u003e\u003cdiv class=\"gs\"\u003e\n\u003cdiv class=\"gs-head\"\u003e\n\u003cdiv class=\"gs-eyebrow\"\u003eFranklin Electric · Constant Pressure Drive\u003c\/div\u003e\n\u003cdiv class=\"gs-title\"\u003eSubDrive and MonoDrive Constant Pressure Controller\u003c\/div\u003e\n\u003cdiv class=\"gs-sub\"\u003e21 Franklin drives: SubDrive Utility, SubDrive Connect, Connect Plus and NEMA 4 models.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"gs-badges\"\u003e\n\u003cdiv class=\"gs-badge\"\u003eConstant Pressure, 25-80 PSI Typical\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003e1\/3 to 30 HP Motors\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003e115-230 V 1Ph or 460 V 3Ph Input\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003eNEMA 3R or NEMA 4\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003eSoft Start and Dry-Run Protection\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003eFE Connect App (Connect Models)\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003e7.7-35.15 lb Weight\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background:#FFFFFF;border:1px solid #C7CBD1;border-top:3px solid #B3122A;padding:12px 16px 12px;margin:16px 0 4px;font-size:13.5px;line-height:1.55;color:#4A4A4F\"\u003e\n\u003cdiv style=\"font-family:Arial Black,Arial,sans-serif;font-size:11px;letter-spacing:1.2px;text-transform:uppercase;color:#B3122A;margin-bottom:8px\"\u003eWhat Ships and What It Needs to Run\u003c\/div\u003e\n\u003cp style=\"margin:0 0 6px\"\u003e\u003cstrong style=\"color:#B3122A\"\u003eIncluded (SubDrive Connect):\u003c\/strong\u003e the drive, pressure transducer, transducer cable, screwdriver adjustment tool, strain relief fitting and owner’s manual.\u003c\/p\u003e\n\u003cp style=\"margin:0 0 6px\"\u003e\u003cstrong style=\"color:#B3122A\"\u003eIncluded (SubDrive Utility):\u003c\/strong\u003e the drive, pressure sensor (transducer on XD models) and boot, sensor cable, adjustment tool, strain relief fitting and owner’s manual.\u003c\/p\u003e\n\u003cp style=\"margin:0 0 6px\"\u003e\u003cstrong style=\"color:#B3122A\"\u003eMatching pump and motor required.\u003c\/strong\u003e Each drive runs the Franklin motor series and horsepower listed for it in the Models \u0026amp; Performance table; the drive replaces the control box and pressure switch.\u003c\/p\u003e\n\u003cp style=\"margin:0\"\u003e\u003cstrong style=\"color:#B3122A\"\u003ePressure tank:\u003c\/strong\u003e required and sized at install; most installations need only a small tank (minimum sizes in each owner’s manual).\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eOverview\u003c\/div\u003e\n\u003cdiv class=\"gs-lead\"\u003e\n\u003cp\u003eSubDrive and MonoDrive variable frequency drives turn a submersible well pump into a constant pressure system: the drive varies motor speed to hold the pressure you set, with soft start and built-in motor protection, and a small pressure tank in most installations.\u003c\/p\u003e\n\u003cp\u003eSubDrive Utility is the economical choice for 115 V and 230 V single-phase 2-wire systems and 230 V 3-wire and three-phase systems up to 2 HP. SubDrive Connect (SubDrive20, 30 and 50) covers 1\/2 to 5 HP single-phase 2-wire, 3-wire and three-phase systems, with FE Connect app connectivity for monitoring, setup and troubleshooting. SubDrive Connect Plus runs three-phase motors up to 30 HP. SubDrive and MonoDrive NEMA 4 drives are the rugged, watertight choice for 1\/2 to 2 HP single-phase 3-wire and 1-1\/2 to 5 HP three-phase systems.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background:#E1E3E6;border-left:3px solid #B8BDC4;padding:8px 14px;font-size:11.5px;color:#4A4A4F;margin-top:14px;line-height:1.5\"\u003eGenuine Franklin Electric equipment, factory-new in original packaging — sold and supported by Watermain Supply, an independent industrial supplier.\u003c\/div\u003e\n\u003cdiv style=\"background:#fff;border-left:5px solid #B3122A;padding:15px 18px;margin-top:12px\"\u003e\n\u003cdiv style=\"font-family:Arial Black,Arial,sans-serif;font-size:15px;color:#B3122A;text-transform:uppercase;letter-spacing:1px;margin-bottom:6px\"\u003e12-Month Franklin Electric Warranty\u003c\/div\u003e\n\u003cp style=\"margin:0;font-size:13.5px;color:#4A4A4F;line-height:1.55\"\u003eFranklin warrants these products for \u003cstrong\u003e1 year from the date of installation, but in no event more than 2 years from the date of manufacture\u003c\/strong\u003e. Franklin’s limited warranty does not cover performance affected by abrasive materials, corrosion due to aggressive conditions or improper voltage supply.\u003c\/p\u003e\n\u003cp style=\"margin:6px 0 0;font-size:12px;color:#9B9EA3;line-height:1.5\"\u003eSource: Franklin Electric SubDrive Connect and SubDrive Utility Owner’s Manuals.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eSpecifications\u003c\/div\u003e\n\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure setting\u003c\/td\u003e\n\u003ctd\u003eFactory preset 50 psi (3.4 bar); adjustable 25-80 psi with the pressure sensor (SubDrive Utility, SubDrive20\/30, NEMA 4); 5-95 psi with the analog transducer (SubDrive50)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure\u003c\/td\u003e\n\u003ctd\u003eNEMA 3R (Utility, Connect, Connect Plus): indoor and outdoor, protection against falling rain and sleet. NEMA 4 (SubDrive75\/100\/150\/300, MonoDrive, MonoDriveXT): watertight, indoor and outdoor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature\u003c\/td\u003e\n\u003ctd\u003e-13 to 122 °F (-25 to 50 °C) Utility and Connect; -13 to 125 °F NEMA 4; -13 to 104 °F (-25 to 40 °C) Connect Plus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection\u003c\/td\u003e\n\u003ctd\u003eUnderload (dry-run), overload\/locked pump, under\/over voltage, open and short circuit, rapid cycle, soft start; phase loss and imbalance on three-phase models\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnectivity\u003c\/td\u003e\n\u003ctd\u003eFE Connect mobile app on SubDrive Connect and Connect Plus; SubDrive Utility is not equipped with the app\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMultiple drives\u003c\/td\u003e\n\u003ctd\u003eLead\/lag\/alternate: accessory for 2 drives on Utility and NEMA 4 models; built-in for 2 drives on SubDrive Connect, up to 8 on Connect Plus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMagForce\u003c\/td\u003e\n\u003ctd\u003eSubDrive Connect and Connect Plus run Franklin MagForce high efficiency permanent magnet motors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\n\u003cp style=\"font-size:12.5px;color:#9B9EA3;margin-top:8px;line-height:1.55\"\u003eSource: Franklin Electric Drives, Controls and Protection Residential and Light Commercial Product Catalog (M5136 04-25), pp. 3-13.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eModels \u0026amp; Ratings\u003c\/div\u003e\n\u003cdiv class=\"gs-lead\"\u003e\n\n\u003cdetails style=\"margin:8px 0;border-top:2px solid #B3122A;padding:6px 0\"\u003e\u003csummary style=\"cursor:pointer;font-weight:bold;color:#4A4A4F\"\u003eFull table · 21 builds\u003c\/summary\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eOrder No.\u003c\/th\u003e\n\u003cth\u003eDrive\u003c\/th\u003e\n\u003cth\u003eEnclosure\u003c\/th\u003e\n\u003cth\u003eInput\u003c\/th\u003e\n\u003cth\u003eOutput to motor\u003c\/th\u003e\n\u003cth\u003ePump it runs (60 Hz)\u003c\/th\u003e\n\u003cth\u003ePressure control\u003c\/th\u003e\n\u003cth\u003eSize (approx.)\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e5870202003\u003c\/td\u003e\n\u003ctd\u003eSubDrive Utility UT2W\u003c\/td\u003e\n\u003ctd\u003eNEMA 3R\u003c\/td\u003e\n\u003ctd\u003e115\/208\/230 +\/- 10% VAC, single-phase\u003c\/td\u003e\n\u003ctd\u003eSingle-phase (2-wire)\u003c\/td\u003e\n\u003ctd\u003e1\/3 hp, 0.25 kW with 244502-Series motor; 1\/2 hp, 0.37 kW with 244504- or 244505-Series motor; 3\/4 hp, 0.55 kW with 244507-Series motor; 1.0 hp, 0.75 kW with 244508-Series motor; 1.5 hp, 1.1 kW with 244309-Series motor\u003c\/td\u003e\n\u003ctd\u003ePressure sensor\u003c\/td\u003e\n\u003ctd\u003e9-3\/4 in x 16-3\/4 in x 5-1\/4 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5870202003XD\u003c\/td\u003e\n\u003ctd\u003eSubDrive Utility UT2W\u003c\/td\u003e\n\u003ctd\u003eNEMA 3R\u003c\/td\u003e\n\u003ctd\u003e115\/208\/230 +\/- 10% VAC, single-phase\u003c\/td\u003e\n\u003ctd\u003eSingle-phase (2-wire)\u003c\/td\u003e\n\u003ctd\u003e1\/3 hp, 0.25 kW with 244502-Series motor; 1\/2 hp, 0.37 kW with 244504- or 244505-Series motor; 3\/4 hp, 0.55 kW with 244507-Series motor; 1.0 hp, 0.75 kW with 244508-Series motor; 1.5 hp, 1.1 kW with 244309-Series motor\u003c\/td\u003e\n\u003ctd\u003eAnalog pressure transducer\u003c\/td\u003e\n\u003ctd\u003e9-3\/4 in x 16-3\/4 in x 5-1\/4 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5870202303\u003c\/td\u003e\n\u003ctd\u003eSubDrive Utility UT3P\u003c\/td\u003e\n\u003ctd\u003eNEMA 3R\u003c\/td\u003e\n\u003ctd\u003e230 +\/- 10% VAC, single-phase\u003c\/td\u003e\n\u003ctd\u003eSingle-phase (3-wire) or three-phase\u003c\/td\u003e\n\u003ctd\u003e1\/2 hp (0.37 kW) pump with 214505-series motor; 3\/4 hp (0.55 kW) pump with 214507-series motor; 1.0 hp (0.75 kW) pump with 214508-series motor; 1.5 hp (1.1 kW) pump with 224300-series motor; 2.0 hp (1.5 kW) pump with 224301-series motor; 1\/2 hp (0.37 kW) pump with 234511-series motor; 3\/4 hp (0.55 kW) pump with 234512-series motor; 1.0 hp (0.75 kW) pump with 234513-series motor; 1.5 hp (1.1 kW) pump with 234514-series motor; 2.0 hp (1.5 kW) pump with 234315-series motor\u003c\/td\u003e\n\u003ctd\u003ePressure sensor\u003c\/td\u003e\n\u003ctd\u003e9-3\/4 in x 16-3\/4 in x 5-1\/4 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5870202303XD\u003c\/td\u003e\n\u003ctd\u003eSubDrive Utility UT3P\u003c\/td\u003e\n\u003ctd\u003eNEMA 3R\u003c\/td\u003e\n\u003ctd\u003e230 +\/- 10% VAC, single-phase\u003c\/td\u003e\n\u003ctd\u003eSingle-phase (3-wire) or three-phase\u003c\/td\u003e\n\u003ctd\u003e1\/2 hp (0.37 kW) pump with 214505-series motor; 3\/4 hp (0.55 kW) pump with 214507-series motor; 1.0 hp (0.75 kW) pump with 214508-series motor; 1.5 hp (1.1 kW) pump with 224300-series motor; 2.0 hp (1.5 kW) pump with 224301-series motor; 1\/2 hp (0.37 kW) pump with 234511-series motor; 3\/4 hp (0.55 kW) pump with 234512-series motor; 1.0 hp (0.75 kW) pump with 234513-series motor; 1.5 hp (1.1 kW) pump with 234514-series motor; 2.0 hp (1.5 kW) pump with 234315-series motor\u003c\/td\u003e\n\u003ctd\u003eAnalog pressure transducer\u003c\/td\u003e\n\u003ctd\u003e9-3\/4 in x 16-3\/4 in x 5-1\/4 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5870205313C\u003c\/td\u003e\n\u003ctd\u003eSubDrive20 Connect\u003c\/td\u003e\n\u003ctd\u003eNEMA 3R\u003c\/td\u003e\n\u003ctd\u003e208\/230 VAC +\/- 10%, single-phase\u003c\/td\u003e\n\u003ctd\u003eSingle-phase (2-wire or 3-wire) OR Three-phase\u003c\/td\u003e\n\u003ctd\u003e230 V single-phase 2-wire motors 1\/2-1-1\/2 hp (244505, 244507, 244508, 244309 series); single-phase 3-wire motors 1\/2-2 hp (214505 to 224301 series); three-phase and MagForce motors per M5136 p. 8\u003c\/td\u003e\n\u003ctd\u003ePressure sensor\u003c\/td\u003e\n\u003ctd\u003e9-3\/4 in x 19-3\/4 in x 5-1\/4 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5870205403C\u003c\/td\u003e\n\u003ctd\u003eSubDrive30 Connect\u003c\/td\u003e\n\u003ctd\u003eNEMA 3R\u003c\/td\u003e\n\u003ctd\u003e208\/230 VAC +\/- 10%, single-phase\u003c\/td\u003e\n\u003ctd\u003eSingle-phase (2-wire or 3-wire) OR Three-phase\u003c\/td\u003e\n\u003ctd\u003e230 V single-phase 2-wire motors 1\/2-1-1\/2 hp (244505, 244507, 244508, 244309 series); single-phase 3-wire motors 1\/2-2 hp (214505 to 224301 series); three-phase and MagForce motors per M5136 p. 8\u003c\/td\u003e\n\u003ctd\u003ePressure sensor\u003c\/td\u003e\n\u003ctd\u003e9-3\/4 in x 19-3\/4 in x 5-1\/4 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5870205503C\u003c\/td\u003e\n\u003ctd\u003eSubDrive50 Connect\u003c\/td\u003e\n\u003ctd\u003eNEMA 3R\u003c\/td\u003e\n\u003ctd\u003e208\/230 +\/- 10% VAC, single-phase\u003c\/td\u003e\n\u003ctd\u003eSingle-phase (3-wire) OR three-phase\u003c\/td\u003e\n\u003ctd\u003eSingle-phase 3-wire motors 1\/2-3 hp (214505 to 224302 series); three-phase and MagForce motors per M5136 p. 8\u003c\/td\u003e\n\u003ctd\u003eAnalog transducer\u003c\/td\u003e\n\u003ctd\u003e26 1\/8 in x 15 3\/8 in x 11 1\/2 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5870203114\u003c\/td\u003e\n\u003ctd\u003eMonoDrive\u003c\/td\u003e\n\u003ctd\u003eNEMA 4\u003c\/td\u003e\n\u003ctd\u003e190-260 VAC, single-phase\u003c\/td\u003e\n\u003ctd\u003eSingle-phase (3-wire)\u003c\/td\u003e\n\u003ctd\u003e0.5 hp (0.37 kW) pump with 214505-Series motor; 0.75 hp (0.55 kW) pump with 214507-Series motor; 1.0 hp (0.75 kW) pump with 214508-Series motor\u003c\/td\u003e\n\u003ctd\u003ePressure sensor\u003c\/td\u003e\n\u003ctd\u003e17-1\/2 in x 16-3\/8 in x 11-3\/8 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5870204114\u003c\/td\u003e\n\u003ctd\u003eMonoDriveXT\u003c\/td\u003e\n\u003ctd\u003eNEMA 4\u003c\/td\u003e\n\u003ctd\u003e190-260 VAC, single-phase\u003c\/td\u003e\n\u003ctd\u003eSingle-phase (3-wire)\u003c\/td\u003e\n\u003ctd\u003e1.5 hp (1.1 kW) pump with 224300-Series motor; 2.0 hp (1.5 kW) pump with 224301-Series motor\u003c\/td\u003e\n\u003ctd\u003ePressure sensor\u003c\/td\u003e\n\u003ctd\u003e17-1\/2 in x 16-3\/8 in x 11-3\/8 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5870203384\u003c\/td\u003e\n\u003ctd\u003eSubDrive75\u003c\/td\u003e\n\u003ctd\u003eNEMA 4\u003c\/td\u003e\n\u003ctd\u003e190-260 VAC, single-phase\u003c\/td\u003e\n\u003ctd\u003eThree-phase (3-wire)\u003c\/td\u003e\n\u003ctd\u003e3\/4 hp (0.55 kW) [default]; 1.0 hp (0.75 kw); 1.5 hp (1.1 kW)\u003c\/td\u003e\n\u003ctd\u003ePressure sensor\u003c\/td\u003e\n\u003ctd\u003e17-1\/2 in x 16-3\/8 in x 11-3\/8 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5870204104\u003c\/td\u003e\n\u003ctd\u003eSubDrive100\u003c\/td\u003e\n\u003ctd\u003eNEMA 4\u003c\/td\u003e\n\u003ctd\u003e190-260 VAC, single-phase\u003c\/td\u003e\n\u003ctd\u003eThree-phase (3-wire)\u003c\/td\u003e\n\u003ctd\u003e1 hp (0.75 kW) [default]; 1.5 hp (1.1 kW); 2 hp (1.5 kW)\u003c\/td\u003e\n\u003ctd\u003ePressure sensor\u003c\/td\u003e\n\u003ctd\u003e17-1\/2 in x 16-3\/8 in x 11-3\/8 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5870204154\u003c\/td\u003e\n\u003ctd\u003eSubDrive150\u003c\/td\u003e\n\u003ctd\u003eNEMA 4\u003c\/td\u003e\n\u003ctd\u003e190-260 VAC, single-phase\u003c\/td\u003e\n\u003ctd\u003eThree-phase (3-wire)\u003c\/td\u003e\n\u003ctd\u003e1.5 hp (1.1 kW) [default]; 2 hp (1.5 kW); 3 hp (2.2 kW)\u003c\/td\u003e\n\u003ctd\u003ePressure sensor\u003c\/td\u003e\n\u003ctd\u003e17-1\/2 in x 16-3\/8 in x 11-3\/8 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5870206300\u003c\/td\u003e\n\u003ctd\u003eSubDrive300\u003c\/td\u003e\n\u003ctd\u003eNEMA 4\u003c\/td\u003e\n\u003ctd\u003e220-260 VAC, single-phase\u003c\/td\u003e\n\u003ctd\u003eThree-phase (3-wire)\u003c\/td\u003e\n\u003ctd\u003e3 hp (2.2 kW) [default]; 5 hp (3.7 kW)\u003c\/td\u003e\n\u003ctd\u003ePressure sensor\u003c\/td\u003e\n\u003ctd\u003e19-7\/8 in x 17-1\/2 in x 14-1\/4 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSDCP-SUB0723\u003c\/td\u003e\n\u003ctd\u003eSubDrive Connect Plus\u003c\/td\u003e\n\u003ctd\u003eNEMA 3R\u003c\/td\u003e\n\u003ctd\u003e230 V, single- or three-phase\u003c\/td\u003e\n\u003ctd\u003eThree-phase\u003c\/td\u003e\n\u003ctd\u003e1-phase input: 3 HP \/ 11 A; 3-phase input: 7.5 HP \/ 28 A rated output\u003c\/td\u003e\n\u003ctd\u003eAnalog transducer\u003c\/td\u003e\n\u003ctd\u003eFrame 2: 10.7 x 9.4 x 27.2 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSDCP-SUB1043\u003c\/td\u003e\n\u003ctd\u003eSubDrive Connect Plus\u003c\/td\u003e\n\u003ctd\u003eNEMA 3R\u003c\/td\u003e\n\u003ctd\u003e460 V, three-phase\u003c\/td\u003e\n\u003ctd\u003eThree-phase\u003c\/td\u003e\n\u003ctd\u003e3-phase input: 10 HP \/ 18 A rated output\u003c\/td\u003e\n\u003ctd\u003eAnalog transducer\u003c\/td\u003e\n\u003ctd\u003eFrame 2: 10.7 x 9.4 x 27.2 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSDCP-SUB1023\u003c\/td\u003e\n\u003ctd\u003eSubDrive Connect Plus\u003c\/td\u003e\n\u003ctd\u003eNEMA 3R\u003c\/td\u003e\n\u003ctd\u003e230 V, single- or three-phase\u003c\/td\u003e\n\u003ctd\u003eThree-phase\u003c\/td\u003e\n\u003ctd\u003e1-phase input: 5 HP \/ 18 A; 3-phase input: 10 HP \/ 37 A rated output\u003c\/td\u003e\n\u003ctd\u003eAnalog transducer\u003c\/td\u003e\n\u003ctd\u003eFrame 2: 10.7 x 9.4 x 27.2 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSDCP-SUB1543\u003c\/td\u003e\n\u003ctd\u003eSubDrive Connect Plus\u003c\/td\u003e\n\u003ctd\u003eNEMA 3R\u003c\/td\u003e\n\u003ctd\u003e460 V, three-phase\u003c\/td\u003e\n\u003ctd\u003eThree-phase\u003c\/td\u003e\n\u003ctd\u003e3-phase input: 15 HP \/ 26 A rated output\u003c\/td\u003e\n\u003ctd\u003eAnalog transducer\u003c\/td\u003e\n\u003ctd\u003eFrame 2: 10.7 x 9.4 x 27.2 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSDCP-SUB1523\u003c\/td\u003e\n\u003ctd\u003eSubDrive Connect Plus\u003c\/td\u003e\n\u003ctd\u003eNEMA 3R\u003c\/td\u003e\n\u003ctd\u003e230 V, single- or three-phase\u003c\/td\u003e\n\u003ctd\u003eThree-phase\u003c\/td\u003e\n\u003ctd\u003e1-phase input: 7.5 HP \/ 27 A; 3-phase input: 15 HP \/ 48 A rated output\u003c\/td\u003e\n\u003ctd\u003eAnalog transducer\u003c\/td\u003e\n\u003ctd\u003eFrame 3: 13.8 x 9.9 x 34.3 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSDCP-SUB2043\u003c\/td\u003e\n\u003ctd\u003eSubDrive Connect Plus\u003c\/td\u003e\n\u003ctd\u003eNEMA 3R\u003c\/td\u003e\n\u003ctd\u003e460 V, three-phase\u003c\/td\u003e\n\u003ctd\u003eThree-phase\u003c\/td\u003e\n\u003ctd\u003e3-phase input: 20 HP \/ 31 A rated output\u003c\/td\u003e\n\u003ctd\u003eAnalog transducer\u003c\/td\u003e\n\u003ctd\u003eFrame 2: 10.7 x 9.4 x 27.2 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSDCP-SUB2543\u003c\/td\u003e\n\u003ctd\u003eSubDrive Connect Plus\u003c\/td\u003e\n\u003ctd\u003eNEMA 3R\u003c\/td\u003e\n\u003ctd\u003e460 V, three-phase\u003c\/td\u003e\n\u003ctd\u003eThree-phase\u003c\/td\u003e\n\u003ctd\u003e3-phase input: 25 HP \/ 39 A rated output\u003c\/td\u003e\n\u003ctd\u003eAnalog transducer\u003c\/td\u003e\n\u003ctd\u003eFrame 3: 13.8 x 9.9 x 34.3 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSDCP-SUB3043\u003c\/td\u003e\n\u003ctd\u003eSubDrive Connect Plus\u003c\/td\u003e\n\u003ctd\u003eNEMA 3R\u003c\/td\u003e\n\u003ctd\u003e460 V, three-phase\u003c\/td\u003e\n\u003ctd\u003eThree-phase\u003c\/td\u003e\n\u003ctd\u003e3-phase input: 30 HP \/ 46 A rated output\u003c\/td\u003e\n\u003ctd\u003eAnalog transducer\u003c\/td\u003e\n\u003ctd\u003eFrame 3: 13.8 x 9.9 x 34.3 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/details\u003e\n\n\u003cp style=\"font-size:12.5px;color:#9B9EA3;margin-top:8px;line-height:1.55\"\u003eSource: Franklin Electric Drives, Controls and Protection Residential and Light Commercial Product Catalog (M5136 04-25), pp. 5-13 (specifications and ordering information); order numbers from the Franklin price list. Size is outer dimensions as Franklin prints them.\u003c\/p\u003e\n\n\u003cdiv style=\"display:flex;flex-wrap:wrap;gap:10px;margin:22px 0 4px\"\u003e\u003ca href=\"\/pages\/submersible-well-pump-sizing-calculator\" style=\"flex:1 1 200px;text-align:center;display:block;background:#B3122A;color:#ffffff;font-family:Arial Black,Arial,sans-serif;font-size:12px;text-transform:uppercase;letter-spacing:1.2px;padding:11px 18px;text-decoration:none\"\u003eSubmersible Calculator\u003c\/a\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"gs-contact\"\u003eFor engineering-led sizing and selection support or a factory submittal, email \u003ca href=\"mailto:sales@watermainsupply.com\"\u003esales@watermainsupply.com\u003c\/a\u003e or call \u003ca href=\"tel:18885104036\"\u003e1-888.510.4036\u003c\/a\u003e.\u003cbr\u003e© Watermain Supply — A division of E4 Industrial LLC\u003c\/div\u003e\n\u003c\/div\u003e\u003ch5\u003eData Sheet\u003c\/h5\u003e\u003cdiv class=\"gs\"\u003e\u003cdiv class=\"gs-dl\"\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0264\/1913\/4527\/files\/Franklin_Electric_Residential_Drives_Controls_Protection_Catalog_M5136.pdf?v=1791090213\" target=\"_blank\" rel=\"noopener\"\u003eDrives, Controls and Protection Residential and Light Commercial Catalog (M5136)\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0264\/1913\/4527\/files\/SubDrive_Connect_Owners_Manual.pdf?v=1791090213\" target=\"_blank\" rel=\"noopener\"\u003eSubDrive Connect Owner’s Manual\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0264\/1913\/4527\/files\/SubDrive_Utility_UT3P_Owners_Manual_226115125.pdf?v=1791090213\" target=\"_blank\" rel=\"noopener\"\u003eSubDrive Utility UT3P Owner’s Manual\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0264\/1913\/4527\/files\/SubDrive_MonoDrive_NEMA1_NEMA4_Installation_Manual_225417101.pdf?v=1791090214\" target=\"_blank\" rel=\"noopener\"\u003eSubDrive and MonoDrive NEMA 1 and NEMA 4 Installation Manual\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0264\/1913\/4527\/files\/SubDrive_MonoDrive_NEMA4_Brochure_M5243.pdf?v=1791090213\" target=\"_blank\" rel=\"noopener\"\u003eSubDrive and MonoDrive NEMA 4 Brochure (M5243)\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0264\/1913\/4527\/files\/SubDrive_QuickPAK_Constant_Pressure_Systems_Catalog_M5008.pdf?v=1791088118\" target=\"_blank\" rel=\"noopener\"\u003eSubDrive QuickPAK Constant Pressure Systems Catalog (M5008)\u003c\/a\u003e\n\u003c\/div\u003e\u003c\/div\u003e\u003ch5\u003eVideos\u003c\/h5\u003e\u003cdiv class=\"gs\"\u003e\u003cdiv class=\"gs-sec\" style=\"margin-top:6px\"\u003e\u003cp style=\"font-size:13px;color:#9B9EA3\"\u003eProduct videos are being added to this listing. For a walkthrough in the meantime, email sales@watermainsupply.com.\u003c\/p\u003e\u003c\/div\u003e\u003c\/div\u003e\u003c!-- \/TABS --\u003e","brand":"Franklin Electric","offers":[{"title":"SubDrive \/ SubDrive 20 Connect N3R - 5870205313C","offer_id":50562118287535,"sku":"5870205313C","price":2667.61,"currency_code":"USD","in_stock":true},{"title":"SubDrive \/ SubDrive 75 N4 - 5870203384","offer_id":50562118320303,"sku":"5870203384","price":3445.77,"currency_code":"USD","in_stock":true},{"title":"SubDrive \/ SubDrive 30 Connect N3R - 5870205403C","offer_id":50562118353071,"sku":"5870205403C","price":3664.53,"currency_code":"USD","in_stock":true},{"title":"SubDrive \/ SubDrive 100 N4 - 5870204104","offer_id":50562118385839,"sku":"5870204104","price":3949.77,"currency_code":"USD","in_stock":true},{"title":"SubDrive \/ SubDrive 50 Connect N3R - 5870205503C","offer_id":50562118418607,"sku":"5870205503C","price":4918.07,"currency_code":"USD","in_stock":true},{"title":"SubDrive \/ SubDrive 150 N4 - 5870204154","offer_id":50562118451375,"sku":"5870204154","price":5579.92,"currency_code":"USD","in_stock":true},{"title":"SubDrive \/ SD Connect Plus 230V 7.5HP 28A with Filter - SDCP-SUB0723","offer_id":50562118484143,"sku":"SDCP-SUB0723","price":5638.07,"currency_code":"USD","in_stock":true},{"title":"SubDrive \/ SD Connect Plus 460V 10HP 18A with Filter - SDCP-SUB1043","offer_id":50562118516911,"sku":"SDCP-SUB1043","price":6017.46,"currency_code":"USD","in_stock":true},{"title":"SubDrive \/ SD Connect Plus 230V 10HP 37A with Filter - SDCP-SUB1023","offer_id":50562118549679,"sku":"SDCP-SUB1023","price":6773.46,"currency_code":"USD","in_stock":true},{"title":"SubDrive \/ SD Connect Plus 460V 15HP 26A with Filter - SDCP-SUB1543","offer_id":50562118582447,"sku":"SDCP-SUB1543","price":6996.84,"currency_code":"USD","in_stock":true},{"title":"SubDrive \/ SD Connect Plus 230V 15HP 48A with Filter - SDCP-SUB1523","offer_id":50562118615215,"sku":"SDCP-SUB1523","price":7914.12,"currency_code":"USD","in_stock":true},{"title":"SubDrive \/ SubDrive 300 N4 - 5870206300","offer_id":50562118647983,"sku":"5870206300","price":8233.77,"currency_code":"USD","in_stock":true},{"title":"SubDrive \/ SD Connect Plus 460V 20HP 31A with Filter - SDCP-SUB2043","offer_id":50562118680751,"sku":"SDCP-SUB2043","price":8534.69,"currency_code":"USD","in_stock":true},{"title":"SubDrive \/ SD Connect Plus 460V 25HP 39A with Filter - SDCP-SUB2543","offer_id":50562118713519,"sku":"SDCP-SUB2543","price":9583.04,"currency_code":"USD","in_stock":true},{"title":"SubDrive \/ SD Connect Plus 460V 30HP 46A with Filter - SDCP-SUB3043","offer_id":50562118746287,"sku":"SDCP-SUB3043","price":11164.28,"currency_code":"USD","in_stock":true},{"title":"MonoDrive \/ MonoDrive N4 - 5870203114","offer_id":50562118779055,"sku":"5870203114","price":3287.92,"currency_code":"USD","in_stock":true},{"title":"MonoDrive \/ MonoDrive XT N4 - 5870204114","offer_id":50562118811823,"sku":"5870204114","price":3889.77,"currency_code":"USD","in_stock":true},{"title":"SubDrive Utility \/ SubDrive Utility UT2W - 5870202003","offer_id":50562118844591,"sku":"5870202003","price":1288.86,"currency_code":"USD","in_stock":true},{"title":"SubDrive Utility \/ SubDrive Utility UT2W (Includes Transducer) - 5870202003XD","offer_id":50562118877359,"sku":"5870202003XD","price":1521.47,"currency_code":"USD","in_stock":true},{"title":"SubDrive Utility \/ SubDrive Utility UT3P - 5870202303","offer_id":50562118910127,"sku":"5870202303","price":1765.17,"currency_code":"USD","in_stock":true},{"title":"SubDrive Utility \/ SubDrive Utility UT3P (Includes Transducer) - 5870202303XD","offer_id":50562118942895,"sku":"5870202303XD","price":1993.17,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0264\/1913\/4527\/files\/SubDrive-Connect_NEMA-3R-Controller_64637546-c9de-4e45-833e-71c30c15897a.jpg?v=1791091712"},{"product_id":"franklin-electric-subdrive-quickpak-constant-pressure-well-pump-package","title":"Franklin Electric SubDrive QuickPAK Constant Pressure Well Pump Package","description":"\u003c!-- TABS --\u003e\u003ch5\u003eDescription\u003c\/h5\u003e\u003cdiv class=\"gs\"\u003e\n\u003cdiv class=\"gs-head\"\u003e\n\u003cdiv class=\"gs-eyebrow\"\u003eFranklin Electric · Constant Pressure System\u003c\/div\u003e\n\u003cdiv class=\"gs-title\"\u003eSubDrive QuickPAK Constant Pressure Well Pump Package\u003c\/div\u003e\n\u003cdiv class=\"gs-sub\"\u003e37 Franklin builds, 7-90 GPM, 1\/2 to 3 HP.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"gs-badges\"\u003e\n\u003cdiv class=\"gs-badge\" style=\"background:#B3122A;color:#FFFFFF;border-color:#B3122A\"\u003e7-90 GPM · Lifts to 1150 ft at 50 PSI\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003e1-1\/2 to 3 HP Three-Phase Motor\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003e208\/230 V 1Ph Supply\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003eNEMA 4 or NEMA 3R Drive\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003eFactory Set 50 PSI\u003c\/div\u003e\n\u003cdiv class=\"gs-badge\"\u003eSoft Start and Dry-Run Protection\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background:#FFFFFF;border:1px solid #C7CBD1;border-top:3px solid #B3122A;padding:12px 16px 12px;margin:16px 0 4px;font-size:13.5px;line-height:1.55;color:#4A4A4F\"\u003e\n\u003cdiv style=\"font-family:Arial Black,Arial,sans-serif;font-size:11px;letter-spacing:1.2px;text-transform:uppercase;color:#B3122A;margin-bottom:8px\"\u003eWhat Ships and What It Needs to Run\u003c\/div\u003e\n\u003cp style=\"margin:0 0 6px\"\u003e\u003cstrong style=\"color:#B3122A\"\u003eIncluded (NEMA 4 builds, -N4):\u003c\/strong\u003e the Franklin 4 in three-phase submersible motor, the matched pump end and the SubDrive75, 100 or 150 NEMA 4 drive with its pressure sensor, as one package.\u003c\/p\u003e\n\u003cp style=\"margin:0 0 6px\"\u003e\u003cstrong style=\"color:#B3122A\"\u003eIncluded (NEMA 3R builds, -3RC):\u003c\/strong\u003e the pump, motor and SubDrive Connect NEMA 3R drive Franklin ships under the order number shown; the SubDrive Connect package includes a pressure transducer.\u003c\/p\u003e\n\u003cp style=\"margin:0 0 6px\"\u003e\u003cstrong style=\"color:#B3122A\"\u003ePower supply:\u003c\/strong\u003e the drive runs on 208\/230 V single-phase service.\u003c\/p\u003e\n\u003cp style=\"margin:0 0 6px\"\u003e\u003cstrong style=\"color:#B3122A\"\u003ePressure tank, drop cable, splice kit and pipe:\u003c\/strong\u003e sized to your installation and ordered separately.\u003c\/p\u003e\n\u003cp style=\"margin:0\"\u003e\u003cstrong style=\"color:#B3122A\"\u003eCheck valve on 35 GPM and larger builds:\u003c\/strong\u003e Franklin supplies high capacity pumps in QuickPAKs without an internal check valve; plan one in the drop pipe.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eOverview\u003c\/div\u003e\n\u003cdiv class=\"gs-lead\"\u003e\n\u003cp\u003eSubDrive QuickPAK is Franklin’s all-in-one constant pressure package: a Franklin submersible pump, motor and SubDrive variable frequency drive selected to work together, so the system is chosen by flow and total dynamic head and installed as one unit. The drive holds the pressure you set as demand changes, with soft start, power factor correction and built-in protection.\u003c\/p\u003e\n\u003cp\u003eThe NEMA 4 builds pair a 230 V three-phase induction motor with a SubDrive NEMA 4 drive in a self-contained, watertight enclosure for harsh conditions. The SubDrive runs the pump end above 60 Hz — up to 80 Hz on 1-1\/2 HP and 70 Hz on 2 HP settings — which is why each build pairs a smaller pump end with a larger motor. The NEMA 3R builds use the SubDrive Connect drive with FE Connect app connectivity.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eConstant pressure across the system, with no fluctuation as faucets and appliances open and close\u003c\/li\u003e\n\u003cli\u003eMotor, pump and drive selected as one package by flow and total dynamic head\u003c\/li\u003e\n\u003cli\u003eNEMA 4 self-contained enclosure on -N4 builds for harsh environments\u003c\/li\u003e\n\u003cli\u003eSubDrive Connect with FE Connect app on -3RC builds\u003c\/li\u003e\n\u003cli\u003eSoft start maximizes system life\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background:#E1E3E6;border-left:3px solid #B8BDC4;padding:8px 14px;font-size:11.5px;color:#4A4A4F;margin-top:14px;line-height:1.5\"\u003eGenuine Franklin Electric equipment, factory-new in original packaging — sold and supported by Watermain Supply, an independent industrial supplier.\u003c\/div\u003e\n\u003cdiv style=\"background:#fff;border-left:5px solid #B3122A;padding:15px 18px;margin-top:12px\"\u003e\n\u003cdiv style=\"font-family:Arial Black,Arial,sans-serif;font-size:15px;color:#B3122A;text-transform:uppercase;letter-spacing:1px;margin-bottom:6px\"\u003e12-Month Franklin Electric Warranty\u003c\/div\u003e\n\u003cp style=\"margin:0;font-size:13.5px;color:#4A4A4F;line-height:1.55\"\u003eFranklin warrants its products for \u003cstrong\u003e12 months from the date of installation, but no more than 24 months from the date of manufacture\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp style=\"margin:6px 0 0;font-size:12px;color:#9B9EA3;line-height:1.5\"\u003eSource: Franklin Electric limited warranty, Submersible Pumps AG\/Industrial\/Municipal Product Catalog.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eSpecifications\u003c\/div\u003e\n\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlow builds\u003c\/td\u003e\n\u003ctd\u003e7, 10, 15, 20, 25, 35, 60 and 90 GPM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor (NEMA 4 builds)\u003c\/td\u003e\n\u003ctd\u003eFranklin 4 in three-phase submersible motor, 230 V, 1-1\/2, 2 or 3 HP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrive (NEMA 4 builds)\u003c\/td\u003e\n\u003ctd\u003eSubDrive75, SubDrive100 or SubDrive150, NEMA 4 self-contained enclosure, pressure sensor included\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDrive (NEMA 3R builds)\u003c\/td\u003e\n\u003ctd\u003eSubDrive Connect, NEMA 3R enclosure, pressure transducer included, FE Connect app\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower supply\u003c\/td\u003e\n\u003ctd\u003e190-260 VAC single-phase (SubDrive NEMA 4); 208\/230 VAC single-phase (SubDrive Connect)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure\u003c\/td\u003e\n\u003ctd\u003eFactory preset 50 psi; adjustable 25-80 psi with the pressure sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput frequency (SubDrive150)\u003c\/td\u003e\n\u003ctd\u003e30-80 Hz on a 1-1\/2 HP pump, 30-70 Hz on 2 HP, 30-60 Hz on 3 HP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBuilt-in protection\u003c\/td\u003e\n\u003ctd\u003eUnderload (dry-run) with adjustable sensitivity, overload and locked pump, undervoltage, electrical surge, broken pipe detection, output short and open circuit, overheated controller\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\n\u003cp style=\"font-size:12.5px;color:#9B9EA3;margin-top:8px;line-height:1.55\"\u003eSource: Franklin Electric SubDrive QuickPAK Constant Pressure Systems Product Catalog (M5008 04-26), pp. 3-7, and Franklin Electric Drives, Controls and Protection Residential and Light Commercial Product Catalog (M5136 04-25), SubDrive specifications.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eModels \u0026amp; Performance — Will It Do What You Need?\u003c\/div\u003e\n\u003cdiv class=\"gs-lead\"\u003e\n\u003cp\u003eFind your horsepower in the row, then read across. Total head is the lift from the pumping water level, plus the system pressure the drive holds (2.31 ft for every PSI), plus friction in the drop pipe. The output tables give the flow at a 30 or 50 PSI pressure setting for your depth to water.\u003c\/p\u003e\n\u003cdetails style=\"margin:8px 0;border-top:2px solid #B3122A;padding:6px 0\"\u003e\u003csummary style=\"cursor:pointer;font-weight:bold;color:#4A4A4F\"\u003e7 GPM class · 3 builds, 1-1\/2 to 3 HP\u003c\/summary\u003e\n\u003cp style=\"margin-bottom:4px\"\u003e\u003cstrong\u003e7 GPM class — total head in feet (curves end at 12.9-13 GPM)\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eHP\u003c\/th\u003e\n\u003cth\u003e0 GPM (Shut-off)\u003c\/th\u003e\n\u003cth\u003e2 GPM\u003c\/th\u003e\n\u003cth\u003e6 GPM\u003c\/th\u003e\n\u003cth\u003e9 GPM\u003c\/th\u003e\n\u003cth\u003e12 GPM\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e1-1\/2 HP\u003c\/td\u003e\n\u003ctd\u003e739\u003c\/td\u003e\n\u003ctd\u003e698\u003c\/td\u003e\n\u003ctd\u003e593\u003c\/td\u003e\n\u003ctd\u003e483\u003c\/td\u003e\n\u003ctd\u003e346\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2 HP\u003c\/td\u003e\n\u003ctd\u003e1005\u003c\/td\u003e\n\u003ctd\u003e983\u003c\/td\u003e\n\u003ctd\u003e816\u003c\/td\u003e\n\u003ctd\u003e658\u003c\/td\u003e\n\u003ctd\u003e471\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3 HP\u003c\/td\u003e\n\u003ctd\u003e1289\u003c\/td\u003e\n\u003ctd\u003e1284\u003c\/td\u003e\n\u003ctd\u003e1071\u003c\/td\u003e\n\u003ctd\u003e868\u003c\/td\u003e\n\u003ctd\u003e629\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"margin-bottom:4px\"\u003e\u003cstrong\u003eOutput in GPM at 30 PSI, by depth to water\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eHP\u003c\/th\u003e\n\u003cth\u003e500 ft\u003c\/th\u003e\n\u003cth\u003e550 ft\u003c\/th\u003e\n\u003cth\u003e600 ft\u003c\/th\u003e\n\u003cth\u003e650 ft\u003c\/th\u003e\n\u003cth\u003e700 ft\u003c\/th\u003e\n\u003cth\u003e750 ft\u003c\/th\u003e\n\u003cth\u003e800 ft\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e1-1\/2 HP\u003c\/td\u003e\n\u003ctd\u003e6\u003c\/td\u003e\n\u003ctd\u003e5\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2 HP\u003c\/td\u003e\n\u003ctd\u003e11\u003c\/td\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003ctd\u003e9\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003ctd\u003e7\u003c\/td\u003e\n\u003ctd\u003e6\u003c\/td\u003e\n\u003ctd\u003e5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3 HP\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e11\u003c\/td\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003ctd\u003e9\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"margin-bottom:4px\"\u003e\u003cstrong\u003eOutput in GPM at 50 PSI, by depth to water\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eHP\u003c\/th\u003e\n\u003cth\u003e500 ft\u003c\/th\u003e\n\u003cth\u003e550 ft\u003c\/th\u003e\n\u003cth\u003e600 ft\u003c\/th\u003e\n\u003cth\u003e650 ft\u003c\/th\u003e\n\u003cth\u003e700 ft\u003c\/th\u003e\n\u003cth\u003e750 ft\u003c\/th\u003e\n\u003cth\u003e800 ft\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e1-1\/2 HP\u003c\/td\u003e\n\u003ctd\u003e5\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2 HP\u003c\/td\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003ctd\u003e9\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003ctd\u003e7\u003c\/td\u003e\n\u003ctd\u003e6\u003c\/td\u003e\n\u003ctd\u003e5\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3 HP\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e11\u003c\/td\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003ctd\u003e9\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails style=\"margin:8px 0;border-top:2px solid #B3122A;padding:6px 0\"\u003e\u003csummary style=\"cursor:pointer;font-weight:bold;color:#4A4A4F\"\u003e10 GPM class · 3 builds, 1-1\/2 to 3 HP\u003c\/summary\u003e\n\u003cp style=\"margin-bottom:4px\"\u003e\u003cstrong\u003e10 GPM class — total head in feet (curves end at 16.3-18 GPM)\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eHP\u003c\/th\u003e\n\u003cth\u003e0 GPM (Shut-off)\u003c\/th\u003e\n\u003cth\u003e3 GPM\u003c\/th\u003e\n\u003cth\u003e8 GPM\u003c\/th\u003e\n\u003cth\u003e12 GPM\u003c\/th\u003e\n\u003cth\u003e16 GPM\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e1-1\/2 HP\u003c\/td\u003e\n\u003ctd\u003e766\u003c\/td\u003e\n\u003ctd\u003e726\u003c\/td\u003e\n\u003ctd\u003e571\u003c\/td\u003e\n\u003ctd\u003e374\u003c\/td\u003e\n\u003ctd\u003e120\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2 HP\u003c\/td\u003e\n\u003ctd\u003e1048\u003c\/td\u003e\n\u003ctd\u003e981\u003c\/td\u003e\n\u003ctd\u003e795\u003c\/td\u003e\n\u003ctd\u003e553\u003c\/td\u003e\n\u003ctd\u003e213\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3 HP\u003c\/td\u003e\n\u003ctd\u003e1152\u003c\/td\u003e\n\u003ctd\u003e1025\u003c\/td\u003e\n\u003ctd\u003e825\u003c\/td\u003e\n\u003ctd\u003e619\u003c\/td\u003e\n\u003ctd\u003e373\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"margin-bottom:4px\"\u003e\u003cstrong\u003eOutput in GPM at 30 PSI, by depth to water\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eHP\u003c\/th\u003e\n\u003cth\u003e200 ft\u003c\/th\u003e\n\u003cth\u003e250 ft\u003c\/th\u003e\n\u003cth\u003e300 ft\u003c\/th\u003e\n\u003cth\u003e350 ft\u003c\/th\u003e\n\u003cth\u003e400 ft\u003c\/th\u003e\n\u003cth\u003e450 ft\u003c\/th\u003e\n\u003cth\u003e500 ft\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e1-1\/2 HP\u003c\/td\u003e\n\u003ctd\u003e14\u003c\/td\u003e\n\u003ctd\u003e13\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003ctd\u003e11\u003c\/td\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003ctd\u003e9\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2 HP\u003c\/td\u003e\n\u003ctd\u003e15\u003c\/td\u003e\n\u003ctd\u003e15\u003c\/td\u003e\n\u003ctd\u003e14\u003c\/td\u003e\n\u003ctd\u003e14\u003c\/td\u003e\n\u003ctd\u003e13\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3 HP\u003c\/td\u003e\n\u003ctd\u003e17\u003c\/td\u003e\n\u003ctd\u003e17\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003ctd\u003e15\u003c\/td\u003e\n\u003ctd\u003e15\u003c\/td\u003e\n\u003ctd\u003e14\u003c\/td\u003e\n\u003ctd\u003e13\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"margin-bottom:4px\"\u003e\u003cstrong\u003eOutput in GPM at 50 PSI, by depth to water\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eHP\u003c\/th\u003e\n\u003cth\u003e200 ft\u003c\/th\u003e\n\u003cth\u003e250 ft\u003c\/th\u003e\n\u003cth\u003e300 ft\u003c\/th\u003e\n\u003cth\u003e350 ft\u003c\/th\u003e\n\u003cth\u003e400 ft\u003c\/th\u003e\n\u003cth\u003e450 ft\u003c\/th\u003e\n\u003cth\u003e500 ft\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e1-1\/2 HP\u003c\/td\u003e\n\u003ctd\u003e13\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003ctd\u003e11\u003c\/td\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003ctd\u003e9\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003ctd\u003e7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2 HP\u003c\/td\u003e\n\u003ctd\u003e15\u003c\/td\u003e\n\u003ctd\u003e14\u003c\/td\u003e\n\u003ctd\u003e14\u003c\/td\u003e\n\u003ctd\u003e13\u003c\/td\u003e\n\u003ctd\u003e13\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003ctd\u003e11\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3 HP\u003c\/td\u003e\n\u003ctd\u003e17\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003ctd\u003e15\u003c\/td\u003e\n\u003ctd\u003e15\u003c\/td\u003e\n\u003ctd\u003e14\u003c\/td\u003e\n\u003ctd\u003e13\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails style=\"margin:8px 0;border-top:2px solid #B3122A;padding:6px 0\"\u003e\u003csummary style=\"cursor:pointer;font-weight:bold;color:#4A4A4F\"\u003e15 GPM class · 3 builds, 1-1\/2 to 3 HP\u003c\/summary\u003e\n\u003cp style=\"margin-bottom:4px\"\u003e\u003cstrong\u003e15 GPM class — total head in feet\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eHP\u003c\/th\u003e\n\u003cth\u003e0 GPM (Shut-off)\u003c\/th\u003e\n\u003cth\u003e5 GPM\u003c\/th\u003e\n\u003cth\u003e13 GPM\u003c\/th\u003e\n\u003cth\u003e19 GPM\u003c\/th\u003e\n\u003cth\u003e25 GPM (Max)\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e1-1\/2 HP\u003c\/td\u003e\n\u003ctd\u003e436\u003c\/td\u003e\n\u003ctd\u003e409\u003c\/td\u003e\n\u003ctd\u003e330\u003c\/td\u003e\n\u003ctd\u003e242\u003c\/td\u003e\n\u003ctd\u003e132\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2 HP\u003c\/td\u003e\n\u003ctd\u003e593\u003c\/td\u003e\n\u003ctd\u003e566\u003c\/td\u003e\n\u003ctd\u003e470\u003c\/td\u003e\n\u003ctd\u003e356\u003c\/td\u003e\n\u003ctd\u003e205\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3 HP\u003c\/td\u003e\n\u003ctd\u003e815\u003c\/td\u003e\n\u003ctd\u003e762\u003c\/td\u003e\n\u003ctd\u003e613\u003c\/td\u003e\n\u003ctd\u003e450\u003c\/td\u003e\n\u003ctd\u003e242\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"margin-bottom:4px\"\u003e\u003cstrong\u003eOutput in GPM at 30 PSI, by depth to water\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eHP\u003c\/th\u003e\n\u003cth\u003e160 ft\u003c\/th\u003e\n\u003cth\u003e180 ft\u003c\/th\u003e\n\u003cth\u003e200 ft\u003c\/th\u003e\n\u003cth\u003e250 ft\u003c\/th\u003e\n\u003cth\u003e300 ft\u003c\/th\u003e\n\u003cth\u003e350 ft\u003c\/th\u003e\n\u003cth\u003e400 ft\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e1-1\/2 HP\u003c\/td\u003e\n\u003ctd\u003e20\u003c\/td\u003e\n\u003ctd\u003e19\u003c\/td\u003e\n\u003ctd\u003e17\u003c\/td\u003e\n\u003ctd\u003e14\u003c\/td\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2 HP\u003c\/td\u003e\n\u003ctd\u003e24\u003c\/td\u003e\n\u003ctd\u003e23\u003c\/td\u003e\n\u003ctd\u003e23\u003c\/td\u003e\n\u003ctd\u003e21\u003c\/td\u003e\n\u003ctd\u003e18\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003ctd\u003e13\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3 HP\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e24\u003c\/td\u003e\n\u003ctd\u003e23\u003c\/td\u003e\n\u003ctd\u003e22\u003c\/td\u003e\n\u003ctd\u003e20\u003c\/td\u003e\n\u003ctd\u003e18\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"margin-bottom:4px\"\u003e\u003cstrong\u003eOutput in GPM at 50 PSI, by depth to water\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eHP\u003c\/th\u003e\n\u003cth\u003e160 ft\u003c\/th\u003e\n\u003cth\u003e180 ft\u003c\/th\u003e\n\u003cth\u003e200 ft\u003c\/th\u003e\n\u003cth\u003e250 ft\u003c\/th\u003e\n\u003cth\u003e300 ft\u003c\/th\u003e\n\u003cth\u003e350 ft\u003c\/th\u003e\n\u003cth\u003e400 ft\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e1-1\/2 HP\u003c\/td\u003e\n\u003ctd\u003e17\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003ctd\u003e14\u003c\/td\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2 HP\u003c\/td\u003e\n\u003ctd\u003e23\u003c\/td\u003e\n\u003ctd\u003e22\u003c\/td\u003e\n\u003ctd\u003e21\u003c\/td\u003e\n\u003ctd\u003e19\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003ctd\u003e13\u003c\/td\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3 HP\u003c\/td\u003e\n\u003ctd\u003e24\u003c\/td\u003e\n\u003ctd\u003e24\u003c\/td\u003e\n\u003ctd\u003e23\u003c\/td\u003e\n\u003ctd\u003e22\u003c\/td\u003e\n\u003ctd\u003e20\u003c\/td\u003e\n\u003ctd\u003e19\u003c\/td\u003e\n\u003ctd\u003e17\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails style=\"margin:8px 0;border-top:2px solid #B3122A;padding:6px 0\"\u003e\u003csummary style=\"cursor:pointer;font-weight:bold;color:#4A4A4F\"\u003e20 GPM class · 3 builds, 1-1\/2 to 3 HP\u003c\/summary\u003e\n\u003cp style=\"margin-bottom:4px\"\u003e\u003cstrong\u003e20 GPM class — total head in feet (curves end at 34.9-35 GPM)\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eHP\u003c\/th\u003e\n\u003cth\u003e0 GPM (Shut-off)\u003c\/th\u003e\n\u003cth\u003e7 GPM\u003c\/th\u003e\n\u003cth\u003e17 GPM\u003c\/th\u003e\n\u003cth\u003e26 GPM\u003c\/th\u003e\n\u003cth\u003e34 GPM\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e1-1\/2 HP\u003c\/td\u003e\n\u003ctd\u003e387\u003c\/td\u003e\n\u003ctd\u003e367\u003c\/td\u003e\n\u003ctd\u003e292\u003c\/td\u003e\n\u003ctd\u003e192\u003c\/td\u003e\n\u003ctd\u003e86\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2 HP\u003c\/td\u003e\n\u003ctd\u003e454\u003c\/td\u003e\n\u003ctd\u003e436\u003c\/td\u003e\n\u003ctd\u003e385\u003c\/td\u003e\n\u003ctd\u003e292\u003c\/td\u003e\n\u003ctd\u003e172\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3 HP\u003c\/td\u003e\n\u003ctd\u003e662\u003c\/td\u003e\n\u003ctd\u003e641\u003c\/td\u003e\n\u003ctd\u003e535\u003c\/td\u003e\n\u003ctd\u003e368\u003c\/td\u003e\n\u003ctd\u003e178\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"margin-bottom:4px\"\u003e\u003cstrong\u003eOutput in GPM at 30 PSI, by depth to water\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eHP\u003c\/th\u003e\n\u003cth\u003e100 ft\u003c\/th\u003e\n\u003cth\u003e120 ft\u003c\/th\u003e\n\u003cth\u003e140 ft\u003c\/th\u003e\n\u003cth\u003e160 ft\u003c\/th\u003e\n\u003cth\u003e180 ft\u003c\/th\u003e\n\u003cth\u003e200 ft\u003c\/th\u003e\n\u003cth\u003e250 ft\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e1-1\/2 HP\u003c\/td\u003e\n\u003ctd\u003e28\u003c\/td\u003e\n\u003ctd\u003e27\u003c\/td\u003e\n\u003ctd\u003e25\u003c\/td\u003e\n\u003ctd\u003e23\u003c\/td\u003e\n\u003ctd\u003e21\u003c\/td\u003e\n\u003ctd\u003e19\u003c\/td\u003e\n\u003ctd\u003e14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2 HP\u003c\/td\u003e\n\u003ctd\u003e34\u003c\/td\u003e\n\u003ctd\u003e32\u003c\/td\u003e\n\u003ctd\u003e31\u003c\/td\u003e\n\u003ctd\u003e30\u003c\/td\u003e\n\u003ctd\u003e29\u003c\/td\u003e\n\u003ctd\u003e28\u003c\/td\u003e\n\u003ctd\u003e24\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3 HP\u003c\/td\u003e\n\u003ctd\u003e34\u003c\/td\u003e\n\u003ctd\u003e33\u003c\/td\u003e\n\u003ctd\u003e32\u003c\/td\u003e\n\u003ctd\u003e32\u003c\/td\u003e\n\u003ctd\u003e31\u003c\/td\u003e\n\u003ctd\u003e31\u003c\/td\u003e\n\u003ctd\u003e29\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"margin-bottom:4px\"\u003e\u003cstrong\u003eOutput in GPM at 50 PSI, by depth to water\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eHP\u003c\/th\u003e\n\u003cth\u003e100 ft\u003c\/th\u003e\n\u003cth\u003e120 ft\u003c\/th\u003e\n\u003cth\u003e140 ft\u003c\/th\u003e\n\u003cth\u003e160 ft\u003c\/th\u003e\n\u003cth\u003e180 ft\u003c\/th\u003e\n\u003cth\u003e200 ft\u003c\/th\u003e\n\u003cth\u003e250 ft\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e1-1\/2 HP\u003c\/td\u003e\n\u003ctd\u003e24\u003c\/td\u003e\n\u003ctd\u003e22\u003c\/td\u003e\n\u003ctd\u003e20\u003c\/td\u003e\n\u003ctd\u003e18\u003c\/td\u003e\n\u003ctd\u003e17\u003c\/td\u003e\n\u003ctd\u003e15\u003c\/td\u003e\n\u003ctd\u003e7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2 HP\u003c\/td\u003e\n\u003ctd\u003e31\u003c\/td\u003e\n\u003ctd\u003e30\u003c\/td\u003e\n\u003ctd\u003e29\u003c\/td\u003e\n\u003ctd\u003e28\u003c\/td\u003e\n\u003ctd\u003e26\u003c\/td\u003e\n\u003ctd\u003e24\u003c\/td\u003e\n\u003ctd\u003e20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3 HP\u003c\/td\u003e\n\u003ctd\u003e32\u003c\/td\u003e\n\u003ctd\u003e32\u003c\/td\u003e\n\u003ctd\u003e31\u003c\/td\u003e\n\u003ctd\u003e30\u003c\/td\u003e\n\u003ctd\u003e30\u003c\/td\u003e\n\u003ctd\u003e29\u003c\/td\u003e\n\u003ctd\u003e26\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails style=\"margin:8px 0;border-top:2px solid #B3122A;padding:6px 0\"\u003e\u003csummary style=\"cursor:pointer;font-weight:bold;color:#4A4A4F\"\u003e25 GPM class · 3 builds, 1-1\/2 to 3 HP\u003c\/summary\u003e\n\u003cp style=\"margin-bottom:4px\"\u003e\u003cstrong\u003e25 GPM class — total head in feet\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eHP\u003c\/th\u003e\n\u003cth\u003e0 GPM (Shut-off)\u003c\/th\u003e\n\u003cth\u003e8 GPM\u003c\/th\u003e\n\u003cth\u003e20 GPM\u003c\/th\u003e\n\u003cth\u003e30 GPM\u003c\/th\u003e\n\u003cth\u003e40 GPM (Max)\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e1-1\/2 HP\u003c\/td\u003e\n\u003ctd\u003e332\u003c\/td\u003e\n\u003ctd\u003e315\u003c\/td\u003e\n\u003ctd\u003e258\u003c\/td\u003e\n\u003ctd\u003e181\u003c\/td\u003e\n\u003ctd\u003e76\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2 HP\u003c\/td\u003e\n\u003ctd\u003e385\u003c\/td\u003e\n\u003ctd\u003e383\u003c\/td\u003e\n\u003ctd\u003e339\u003c\/td\u003e\n\u003ctd\u003e259\u003c\/td\u003e\n\u003ctd\u003e154\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3 HP\u003c\/td\u003e\n\u003ctd\u003e505\u003c\/td\u003e\n\u003ctd\u003e500\u003c\/td\u003e\n\u003ctd\u003e436\u003c\/td\u003e\n\u003ctd\u003e336\u003c\/td\u003e\n\u003ctd\u003e206\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"margin-bottom:4px\"\u003e\u003cstrong\u003eOutput in GPM at 30 PSI, by depth to water\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eHP\u003c\/th\u003e\n\u003cth\u003e100 ft\u003c\/th\u003e\n\u003cth\u003e120 ft\u003c\/th\u003e\n\u003cth\u003e140 ft\u003c\/th\u003e\n\u003cth\u003e160 ft\u003c\/th\u003e\n\u003cth\u003e180 ft\u003c\/th\u003e\n\u003cth\u003e200 ft\u003c\/th\u003e\n\u003cth\u003e250 ft\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e1-1\/2 HP\u003c\/td\u003e\n\u003ctd\u003e32\u003c\/td\u003e\n\u003ctd\u003e29\u003c\/td\u003e\n\u003ctd\u003e27\u003c\/td\u003e\n\u003ctd\u003e24\u003c\/td\u003e\n\u003ctd\u003e21\u003c\/td\u003e\n\u003ctd\u003e18\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2 HP\u003c\/td\u003e\n\u003ctd\u003e37\u003c\/td\u003e\n\u003ctd\u003e36\u003c\/td\u003e\n\u003ctd\u003e35\u003c\/td\u003e\n\u003ctd\u003e34\u003c\/td\u003e\n\u003ctd\u003e31\u003c\/td\u003e\n\u003ctd\u003e29\u003c\/td\u003e\n\u003ctd\u003e23\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3 HP\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e40\u003c\/td\u003e\n\u003ctd\u003e37\u003c\/td\u003e\n\u003ctd\u003e36\u003c\/td\u003e\n\u003ctd\u003e35\u003c\/td\u003e\n\u003ctd\u003e32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"margin-bottom:4px\"\u003e\u003cstrong\u003eOutput in GPM at 50 PSI, by depth to water\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eHP\u003c\/th\u003e\n\u003cth\u003e100 ft\u003c\/th\u003e\n\u003cth\u003e120 ft\u003c\/th\u003e\n\u003cth\u003e140 ft\u003c\/th\u003e\n\u003cth\u003e160 ft\u003c\/th\u003e\n\u003cth\u003e180 ft\u003c\/th\u003e\n\u003cth\u003e200 ft\u003c\/th\u003e\n\u003cth\u003e250 ft\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e1-1\/2 HP\u003c\/td\u003e\n\u003ctd\u003e26\u003c\/td\u003e\n\u003ctd\u003e23\u003c\/td\u003e\n\u003ctd\u003e20\u003c\/td\u003e\n\u003ctd\u003e17\u003c\/td\u003e\n\u003ctd\u003e14\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2 HP\u003c\/td\u003e\n\u003ctd\u003e35\u003c\/td\u003e\n\u003ctd\u003e33\u003c\/td\u003e\n\u003ctd\u003e31\u003c\/td\u003e\n\u003ctd\u003e28\u003c\/td\u003e\n\u003ctd\u003e26\u003c\/td\u003e\n\u003ctd\u003e23\u003c\/td\u003e\n\u003ctd\u003e14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3 HP\u003c\/td\u003e\n\u003ctd\u003e39\u003c\/td\u003e\n\u003ctd\u003e37\u003c\/td\u003e\n\u003ctd\u003e36\u003c\/td\u003e\n\u003ctd\u003e35\u003c\/td\u003e\n\u003ctd\u003e34\u003c\/td\u003e\n\u003ctd\u003e32\u003c\/td\u003e\n\u003ctd\u003e27\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails style=\"margin:8px 0;border-top:2px solid #B3122A;padding:6px 0\"\u003e\u003csummary style=\"cursor:pointer;font-weight:bold;color:#4A4A4F\"\u003e35 GPM class · 3 builds, 1-1\/2 to 3 HP\u003c\/summary\u003e\n\u003cp style=\"margin-bottom:4px\"\u003e\u003cstrong\u003e35 GPM class — total head in feet (curves end at 57.9-60 GPM)\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eHP\u003c\/th\u003e\n\u003cth\u003e0 GPM (Shut-off)\u003c\/th\u003e\n\u003cth\u003e11 GPM\u003c\/th\u003e\n\u003cth\u003e29 GPM\u003c\/th\u003e\n\u003cth\u003e43 GPM\u003c\/th\u003e\n\u003cth\u003e57 GPM\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e1-1\/2 HP\u003c\/td\u003e\n\u003ctd\u003e253\u003c\/td\u003e\n\u003ctd\u003e228\u003c\/td\u003e\n\u003ctd\u003e190\u003c\/td\u003e\n\u003ctd\u003e134\u003c\/td\u003e\n\u003ctd\u003e59\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2 HP\u003c\/td\u003e\n\u003ctd\u003e297\u003c\/td\u003e\n\u003ctd\u003e261\u003c\/td\u003e\n\u003ctd\u003e240\u003c\/td\u003e\n\u003ctd\u003e189\u003c\/td\u003e\n\u003ctd\u003e110\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3 HP\u003c\/td\u003e\n\u003ctd\u003e392\u003c\/td\u003e\n\u003ctd\u003e362\u003c\/td\u003e\n\u003ctd\u003e325\u003c\/td\u003e\n\u003ctd\u003e246\u003c\/td\u003e\n\u003ctd\u003e138\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"margin-bottom:4px\"\u003e\u003cstrong\u003eOutput in GPM at 30 PSI, by depth to water\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eHP\u003c\/th\u003e\n\u003cth\u003e20 ft\u003c\/th\u003e\n\u003cth\u003e40 ft\u003c\/th\u003e\n\u003cth\u003e60 ft\u003c\/th\u003e\n\u003cth\u003e80 ft\u003c\/th\u003e\n\u003cth\u003e100 ft\u003c\/th\u003e\n\u003cth\u003e120 ft\u003c\/th\u003e\n\u003cth\u003e140 ft\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e1-1\/2 HP\u003c\/td\u003e\n\u003ctd\u003e47\u003c\/td\u003e\n\u003ctd\u003e42\u003c\/td\u003e\n\u003ctd\u003e37\u003c\/td\u003e\n\u003ctd\u003e33\u003c\/td\u003e\n\u003ctd\u003e28\u003c\/td\u003e\n\u003ctd\u003e24\u003c\/td\u003e\n\u003ctd\u003e19\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2 HP\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e51\u003c\/td\u003e\n\u003ctd\u003e47\u003c\/td\u003e\n\u003ctd\u003e44\u003c\/td\u003e\n\u003ctd\u003e39\u003c\/td\u003e\n\u003ctd\u003e34\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3 HP\u003c\/td\u003e\n\u003ctd\u003e58\u003c\/td\u003e\n\u003ctd\u003e56\u003c\/td\u003e\n\u003ctd\u003e54\u003c\/td\u003e\n\u003ctd\u003e52\u003c\/td\u003e\n\u003ctd\u003e49\u003c\/td\u003e\n\u003ctd\u003e46\u003c\/td\u003e\n\u003ctd\u003e43\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"margin-bottom:4px\"\u003e\u003cstrong\u003eOutput in GPM at 50 PSI, by depth to water\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eHP\u003c\/th\u003e\n\u003cth\u003e20 ft\u003c\/th\u003e\n\u003cth\u003e40 ft\u003c\/th\u003e\n\u003cth\u003e60 ft\u003c\/th\u003e\n\u003cth\u003e80 ft\u003c\/th\u003e\n\u003cth\u003e100 ft\u003c\/th\u003e\n\u003cth\u003e120 ft\u003c\/th\u003e\n\u003cth\u003e140 ft\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e1-1\/2 HP\u003c\/td\u003e\n\u003ctd\u003e36\u003c\/td\u003e\n\u003ctd\u003e31\u003c\/td\u003e\n\u003ctd\u003e27\u003c\/td\u003e\n\u003ctd\u003e22\u003c\/td\u003e\n\u003ctd\u003e18\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2 HP\u003c\/td\u003e\n\u003ctd\u003e50\u003c\/td\u003e\n\u003ctd\u003e46\u003c\/td\u003e\n\u003ctd\u003e42\u003c\/td\u003e\n\u003ctd\u003e38\u003c\/td\u003e\n\u003ctd\u003e33\u003c\/td\u003e\n\u003ctd\u003e28\u003c\/td\u003e\n\u003ctd\u003e24\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3 HP\u003c\/td\u003e\n\u003ctd\u003e54\u003c\/td\u003e\n\u003ctd\u003e51\u003c\/td\u003e\n\u003ctd\u003e48\u003c\/td\u003e\n\u003ctd\u003e45\u003c\/td\u003e\n\u003ctd\u003e42\u003c\/td\u003e\n\u003ctd\u003e38\u003c\/td\u003e\n\u003ctd\u003e35\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails style=\"margin:8px 0;border-top:2px solid #B3122A;padding:6px 0\"\u003e\u003csummary style=\"cursor:pointer;font-weight:bold;color:#4A4A4F\"\u003e60 GPM class · 1 build, 3 HP\u003c\/summary\u003e\n\u003cp style=\"margin-bottom:4px\"\u003e\u003cstrong\u003e60 GPM class — total head in feet\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eHP\u003c\/th\u003e\n\u003cth\u003e0 GPM (Shut-off)\u003c\/th\u003e\n\u003cth\u003e18 GPM\u003c\/th\u003e\n\u003cth\u003e45 GPM\u003c\/th\u003e\n\u003cth\u003e67 GPM\u003c\/th\u003e\n\u003cth\u003e89 GPM (Max)\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e3 HP\u003c\/td\u003e\n\u003ctd\u003e286\u003c\/td\u003e\n\u003ctd\u003e243\u003c\/td\u003e\n\u003ctd\u003e190\u003c\/td\u003e\n\u003ctd\u003e146\u003c\/td\u003e\n\u003ctd\u003e87\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"margin-bottom:4px\"\u003e\u003cstrong\u003eOutput in GPM at 30 PSI, by depth to water\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eHP\u003c\/th\u003e\n\u003cth\u003e20 ft\u003c\/th\u003e\n\u003cth\u003e40 ft\u003c\/th\u003e\n\u003cth\u003e60 ft\u003c\/th\u003e\n\u003cth\u003e80 ft\u003c\/th\u003e\n\u003cth\u003e100 ft\u003c\/th\u003e\n\u003cth\u003e120 ft\u003c\/th\u003e\n\u003cth\u003e140 ft\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e3 HP\u003c\/td\u003e\n\u003ctd\u003e87\u003c\/td\u003e\n\u003ctd\u003e76\u003c\/td\u003e\n\u003ctd\u003e68\u003c\/td\u003e\n\u003ctd\u003e60\u003c\/td\u003e\n\u003ctd\u003e53\u003c\/td\u003e\n\u003ctd\u003e45\u003c\/td\u003e\n\u003ctd\u003e38\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"margin-bottom:4px\"\u003e\u003cstrong\u003eOutput in GPM at 50 PSI, by depth to water\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eHP\u003c\/th\u003e\n\u003cth\u003e20 ft\u003c\/th\u003e\n\u003cth\u003e40 ft\u003c\/th\u003e\n\u003cth\u003e60 ft\u003c\/th\u003e\n\u003cth\u003e80 ft\u003c\/th\u003e\n\u003cth\u003e100 ft\u003c\/th\u003e\n\u003cth\u003e120 ft\u003c\/th\u003e\n\u003cth\u003e140 ft\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e3 HP\u003c\/td\u003e\n\u003ctd\u003e65\u003c\/td\u003e\n\u003ctd\u003e58\u003c\/td\u003e\n\u003ctd\u003e50\u003c\/td\u003e\n\u003ctd\u003e43\u003c\/td\u003e\n\u003ctd\u003e35\u003c\/td\u003e\n\u003ctd\u003e28\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails style=\"margin:8px 0;border-top:2px solid #B3122A;padding:6px 0\"\u003e\u003csummary style=\"cursor:pointer;font-weight:bold;color:#4A4A4F\"\u003e90 GPM class · 1 build, 3 HP\u003c\/summary\u003e\n\u003cp style=\"margin-bottom:4px\"\u003e\u003cstrong\u003e90 GPM class — total head in feet\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eHP\u003c\/th\u003e\n\u003cth\u003e0 GPM (Shut-off)\u003c\/th\u003e\n\u003cth\u003e27 GPM\u003c\/th\u003e\n\u003cth\u003e68 GPM\u003c\/th\u003e\n\u003cth\u003e101 GPM\u003c\/th\u003e\n\u003cth\u003e135 GPM (Max)\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e3 HP\u003c\/td\u003e\n\u003ctd\u003e175\u003c\/td\u003e\n\u003ctd\u003e189\u003c\/td\u003e\n\u003ctd\u003e132\u003c\/td\u003e\n\u003ctd\u003e102\u003c\/td\u003e\n\u003ctd\u003e58\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"margin-bottom:4px\"\u003e\u003cstrong\u003eOutput in GPM at 30 PSI, by depth to water\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eHP\u003c\/th\u003e\n\u003cth\u003e20 ft\u003c\/th\u003e\n\u003cth\u003e40 ft\u003c\/th\u003e\n\u003cth\u003e60 ft\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e3 HP\u003c\/td\u003e\n\u003ctd\u003e95\u003c\/td\u003e\n\u003ctd\u003e77\u003c\/td\u003e\n\u003ctd\u003e58\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp style=\"margin-bottom:4px\"\u003e\u003cstrong\u003eOutput in GPM at 50 PSI, by depth to water\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\u003ctable class=\"gs-tbl\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eHP\u003c\/th\u003e\n\u003cth\u003e20 ft\u003c\/th\u003e\n\u003cth\u003e40 ft\u003c\/th\u003e\n\u003cth\u003e60 ft\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e3 HP\u003c\/td\u003e\n\u003ctd\u003e52\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cp style=\"font-size:12.5px;color:#9B9EA3;margin-top:6px;line-height:1.55\"\u003eTotal head at maximum drive speed, read from the published curves in Franklin’s SubDrive QuickPAK catalog (M5008), pp. 9-47, digitized and rounded down to whole feet, at the plotted flows nearest 20%, 50% and 75% of where the curves end. 0 GPM is Franklin’s printed shut-off pressure at zero lift, in feet (PSI × 2.31). Franklin’s published curves and printed tables differ by more than 3% on the 7 GPM 3 HP, 35 GPM 1-1\/2 HP, 35 GPM 2 HP, 35 GPM 3 HP and 90 GPM 3 HP builds. The head table follows the published curve, re-checked against Franklin’s chart; the 0 GPM column and the output tables follow the printed figures. Output tables as printed in M5008, pp. 9-47, at the 30 and 50 PSI rows; Franklin rounds them to whole GPM. Drop-pipe friction is not included. — marks a point Franklin does not print.\u003c\/p\u003e\n\u003cp style=\"font-size:12.5px;color:#9B9EA3;margin-top:6px;line-height:1.55\"\u003eThe 90 GPM curves rise a few feet above the printed shut-off at low flow before they fall, so a low-flow column can read slightly above the shut-off.\u003c\/p\u003e\n\u003cp style=\"font-size:12.5px;color:#9B9EA3;margin-top:6px;line-height:1.55\"\u003eFranklin’s QuickPAK catalog (M5008) prints performance for the NEMA 4 builds; the NEMA 3R builds (-3RC) and 10-3WQP-0.5HP-3RC are confirmed on request.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBest operating range:\u003c\/strong\u003e Franklin marks the recommended operating range on each published curve and prints no figures for it. The curves are in the image gallery.\u003c\/p\u003e\n\u003cdiv style=\"display:flex;flex-wrap:wrap;gap:10px;margin:22px 0 4px\"\u003e\u003ca href=\"\/pages\/submersible-well-pump-sizing-calculator\" style=\"flex:1 1 200px;text-align:center;display:block;background:#B3122A;color:#ffffff;font-family:Arial Black,Arial,sans-serif;font-size:12px;text-transform:uppercase;letter-spacing:1.2px;padding:11px 18px;text-decoration:none\"\u003eSubmersible Calculator\u003c\/a\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"gs-sec\"\u003e\n\u003cdiv class=\"gs-h\"\u003eBefore You Buy — The Limits That Decide the Fit\u003c\/div\u003e\n\u003cdiv class=\"gs-lead\"\u003e\n\u003cul\u003e\n\u003cli\u003eSupply: 208\/230 V single-phase to the drive; the three-phase motor runs only from its SubDrive\u003c\/li\u003e\n\u003cli\u003eMatch the build to your pumping water level and pressure using the table above\u003c\/li\u003e\n\u003cli\u003eMotor cable: maximum lengths in feet for 600 V copper, 75 °C insulation are in the table below (NEMA 4 builds)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"gs-contact\"\u003eFor engineering-led sizing and selection support or a factory submittal, email \u003ca href=\"mailto:sales@watermainsupply.com\"\u003esales@watermainsupply.com\u003c\/a\u003e or call \u003ca href=\"tel:18885104036\"\u003e1-888.510.4036\u003c\/a\u003e.\u003cbr\u003e© Watermain Supply — A division of E4 Industrial LLC\u003c\/div\u003e\n\u003c\/div\u003e\u003ch5\u003eData Sheet\u003c\/h5\u003e\u003cdiv class=\"gs\"\u003e\u003cdiv class=\"gs-dl\"\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0264\/1913\/4527\/files\/SubDrive_QuickPAK_Constant_Pressure_Systems_Catalog_M5008.pdf?v=1791088118\" target=\"_blank\" rel=\"noopener\"\u003eSubDrive QuickPAK Constant Pressure Systems Catalog (M5008)\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0264\/1913\/4527\/files\/SubDrive_MonoDrive_NEMA1_NEMA4_Installation_Manual_225417101.pdf?v=1791090214\" target=\"_blank\" rel=\"noopener\"\u003eSubDrive and MonoDrive NEMA 1 and NEMA 4 Installation Manual\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0264\/1913\/4527\/files\/SubDrive_Connect_Owners_Manual.pdf?v=1791090213\" target=\"_blank\" rel=\"noopener\"\u003eSubDrive Connect Owner’s Manual\u003c\/a\u003e\n\u003c\/div\u003e\u003c\/div\u003e\u003ch5\u003eVideos\u003c\/h5\u003e\u003cdiv class=\"gs\"\u003e\u003cdiv class=\"gs-sec\" style=\"margin-top:6px\"\u003e\u003cp style=\"font-size:13px;color:#9B9EA3\"\u003eProduct videos are being added to this listing. For a walkthrough in the meantime, email sales@watermainsupply.com.\u003c\/p\u003e\u003c\/div\u003e\u003c\/div\u003e\u003c!-- \/TABS --\u003e","brand":"Franklin Electric","offers":[{"title":"7 GPM \/ 1-1\/2 HP \/ NEMA 4 - 7SDQP-1.5HP-N4","offer_id":50562118975663,"sku":"93800760","price":4560.99,"currency_code":"USD","in_stock":true},{"title":"7 GPM \/ 1-1\/2 HP \/ NEMA 3R - 7SDQP-1.5HP-3RC","offer_id":50562119008431,"sku":"93805224C","price":4263.93,"currency_code":"USD","in_stock":true},{"title":"7 GPM \/ 2 HP \/ NEMA 4 - 7SDQP-2.0HP-N4","offer_id":50562119041199,"sku":"93800772","price":5227.68,"currency_code":"USD","in_stock":true},{"title":"7 GPM \/ 2 HP \/ NEMA 3R - 7SDQP-2.0HP-3RC","offer_id":50562119073967,"sku":"93805425C","price":4740.18,"currency_code":"USD","in_stock":true},{"title":"7 GPM \/ 3 HP \/ NEMA 4 - 7SDQP-3.0HP-N4","offer_id":50562119106735,"sku":"93800710","price":7176.99,"currency_code":"USD","in_stock":true},{"title":"10 GPM \/ 1\/2 HP \/ NEMA 3R 3-Wire - 10-3WQP-0.5HP-3RC","offer_id":50562119139503,"sku":"93975131C","price":3244.59,"currency_code":"USD","in_stock":true},{"title":"10 GPM \/ 1-1\/2 HP \/ NEMA 4 - 10SDQP-1.5HP-N4","offer_id":50562119172271,"sku":"93801002","price":4389.99,"currency_code":"USD","in_stock":true},{"title":"10 GPM \/ 1-1\/2 HP \/ NEMA 3R - 10SDQP-1.5HP-3RC","offer_id":50562119205039,"sku":"93805234C","price":4084.68,"currency_code":"USD","in_stock":true},{"title":"10 GPM \/ 2 HP \/ NEMA 4 - 10SDQP-2.0HP-N4","offer_id":50562119237807,"sku":"93801062","price":5038.68,"currency_code":"USD","in_stock":true},{"title":"10 GPM \/ 2 HP \/ NEMA 3R - 10SDQP-2.0HP-3RC","offer_id":50562119270575,"sku":"93805435C","price":4543.68,"currency_code":"USD","in_stock":true},{"title":"10 GPM \/ 3 HP \/ NEMA 4 - 10SDQP-3.0HP-N4","offer_id":50562119303343,"sku":"93801004","price":7475.49,"currency_code":"USD","in_stock":true},{"title":"15 GPM \/ 1-1\/2 HP \/ NEMA 4 - 15SDQP-1.5HP-N4","offer_id":50562119336111,"sku":"93801502","price":4371.18,"currency_code":"USD","in_stock":true},{"title":"15 GPM \/ 1-1\/2 HP \/ NEMA 3R - 15SDQP-1.5HP-3RC","offer_id":50562119368879,"sku":"93805244C","price":4090.68,"currency_code":"USD","in_stock":true},{"title":"15 GPM \/ 2 HP \/ NEMA 4 - 15SDQP-2.0HP-N4","offer_id":50562119401647,"sku":"93801511","price":4914.18,"currency_code":"USD","in_stock":true},{"title":"15 GPM \/ 2 HP \/ NEMA 3R - 15SDQP-2.0HP-3RC","offer_id":50562119434415,"sku":"93805445C","price":4428.99,"currency_code":"USD","in_stock":true},{"title":"15 GPM \/ 3 HP \/ NEMA 4 - 15SDQP-3.0HP-N4","offer_id":50562119467183,"sku":"93801504","price":6840.99,"currency_code":"USD","in_stock":true},{"title":"20 GPM \/ 1-1\/2 HP \/ NEMA 4 - 20SDQP-1.5HP-N4","offer_id":50562119499951,"sku":"93802002","price":4576.68,"currency_code":"USD","in_stock":true},{"title":"20 GPM \/ 1-1\/2 HP \/ NEMA 3R - 20SDQP-1.5HP-3RC","offer_id":50562119532719,"sku":"93805254C","price":4304.43,"currency_code":"USD","in_stock":true},{"title":"20 GPM \/ 2 HP \/ NEMA 4 - 20SDQP-2.0HP-N4","offer_id":50562119565487,"sku":"93802036","price":5020.68,"currency_code":"USD","in_stock":true},{"title":"20 GPM \/ 2 HP \/ NEMA 3R - 20SDQP-2.0HP-3RC","offer_id":50562119598255,"sku":"93805455C","price":4523.43,"currency_code":"USD","in_stock":true},{"title":"20 GPM \/ 3 HP \/ NEMA 4 - 20SDQP-3.0HP-N4","offer_id":50562119631023,"sku":"93802004","price":7239.99,"currency_code":"USD","in_stock":true},{"title":"20 GPM \/ 3 HP \/ NEMA 3R - 20SDQP-3.0HP-3RC","offer_id":50562119663791,"sku":"93805556C","price":6055.74,"currency_code":"USD","in_stock":true},{"title":"25 GPM \/ 1-1\/2 HP \/ NEMA 4 - 25SDQP-1.5HP-N4","offer_id":50562119696559,"sku":"93802502","price":4436.43,"currency_code":"USD","in_stock":true},{"title":"25 GPM \/ 1-1\/2 HP \/ NEMA 3R - 25SDQP-1.5HP-3RC","offer_id":50562119729327,"sku":"93805264C","price":4156.68,"currency_code":"USD","in_stock":true},{"title":"25 GPM \/ 2 HP \/ NEMA 4 - 25SDQP-2.0HP-N4","offer_id":50562119762095,"sku":"93802530","price":4880.43,"currency_code":"USD","in_stock":true},{"title":"25 GPM \/ 2 HP \/ NEMA 3R - 25SDQP-2.0HP-3RC","offer_id":50562119794863,"sku":"93805465C","price":4377.18,"currency_code":"USD","in_stock":true},{"title":"25 GPM \/ 3 HP \/ NEMA 4 - 25SDQP-3.0HP-N4","offer_id":50562119827631,"sku":"93802504","price":6953.49,"currency_code":"USD","in_stock":true},{"title":"25 GPM \/ 3 HP \/ NEMA 3R - 25SDQP-3.0HP-3RC","offer_id":50562119860399,"sku":"93805566C","price":5769.24,"currency_code":"USD","in_stock":true},{"title":"35 GPM \/ 1-1\/2 HP \/ NEMA 4 - 35SDQP-1.5HP-N4","offer_id":50562119893167,"sku":"93803514","price":4785.18,"currency_code":"USD","in_stock":true},{"title":"35 GPM \/ 1-1\/2 HP \/ NEMA 3R - 35SDQP-1.5HP-3RC","offer_id":50562119925935,"sku":"93805274C","price":4521.93,"currency_code":"USD","in_stock":true},{"title":"35 GPM \/ 2 HP \/ NEMA 4 - 35SDQP-2.0HP-N4","offer_id":50562119958703,"sku":"93803520","price":5249.49,"currency_code":"USD","in_stock":true},{"title":"35 GPM \/ 2 HP \/ NEMA 3R - 35SDQP-2.0HP-3RC","offer_id":50562119991471,"sku":"93805475C","price":4764.24,"currency_code":"USD","in_stock":true},{"title":"35 GPM \/ 3 HP \/ NEMA 4 - 35SDQP-3.0HP-N4","offer_id":50562120024239,"sku":"93803528","price":7049.49,"currency_code":"USD","in_stock":true},{"title":"35 GPM \/ 3 HP \/ NEMA 3R - 35SDQP-3.0HP-3RC","offer_id":50562120057007,"sku":"93805576C","price":5866.74,"currency_code":"USD","in_stock":true},{"title":"60 GPM \/ 3 HP \/ NEMA 4 - 60SDQP-3.0HP-N4","offer_id":50562120089775,"sku":"93806016","price":7326.99,"currency_code":"USD","in_stock":true},{"title":"60 GPM \/ 3 HP \/ NEMA 3R - 60SDQP-3.0HP-3RC","offer_id":50562120122543,"sku":"93805586C","price":6141.99,"currency_code":"USD","in_stock":true},{"title":"90 GPM \/ 3 HP \/ NEMA 4 - 90SDQP-3.0HP-N4","offer_id":50562120155311,"sku":"93809010","price":7269.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0264\/1913\/4527\/files\/SubDrive-QuickPAK_Packaged-System-with-Carton_c5343cf1-4bbc-4169-bc99-d6a5c42c4eda.jpg?v=1791088904"}],"url":"https:\/\/watermainsupply.com\/collections\/constant-pressure-well-pump-packages.oembed","provider":"Watermainsupply","version":"1.0","type":"link"}